OPERATION MANUAL - Flexible Scientific
Contents
1. Increase time by 1 minute Alt T Move an edited point to the right the following step Alt Move an edited point to the left a previous step Alt Move an edited point to the left a previous step Alt gt Move an edited point to the right the following step Last step delete lt 2 Delete the last set step All step delete 2 Delete all set steps 4 Pattern save at Save programmed pattern File extension is PIT Choose a folder and write a file name Then click save button Pattern open Choose a pattern file and click open Start at Click the START icon to operate the equipment after pattern is set Note i If the main body is under abnormal condition such as Door Open Over Temp and etc the main unit will not operate li The main body must be set as a Con P mode To convert to Con P mode press and hold the lock button for more than 1 second If you want to operate the unit in Con L mode Local mode press and hold lock button for more than 1 second Only lock button works in the display panel of main body at a Con P mode Page 43 vi f you set the number of pattern repetition the main body will work as Lab Companion Pattern program R FA a o oV pattern programming m Step 2 4 gt Temp 130 C Time 20 jmin Enter Repetition f me Deleting the previous data r Pic 4 Step informa
2. handling on this unit Caution means that the user may have CAUTION minor damage and unit may have physical damage by improper handling Page 2 is Although Jeio Tech thoroughly investigates the possibilities of dangerous situations from using the product it is not possible to know every single danger Hence precautions described in this manual do not cover all the dangerous conditions Lab Companion However you can operate this product safer when you follow the directions in this manual Please be sure to pay attention to the directions and be cautious so that a mechanical trouble or an accident would not be occurred 2 Warning mark of product The most important thing of the warning is a warning label attached to the product It is located in front of the door Be fully aware of the warning contents during operation x Please change to the new warning label when it is unreadable from wearing out Please request the new label to us Copyright 2004 Jeiotech co Ltd ALL RIGHT RESERVED Page 3 7 Lab Companion vi Contents VetFOF SAIC ODCIAUOM spine 5 2 Application and Features aise conidanstrncseered nl nccnccdasteacesantetettataamarcen 5 Se INStANAUON sses N Oe T A PrecCaUtONS sarena a E E 12 5 Name ofthe each panl senirensoa re 13 6 Operating Controller onaansansannnnonrnrrnrnrnrnnrnnrrnrnnrnrrnrrnrrnernrnnnne 17 7 Maintenance and Cleaning c cece ccc cccecceccee
3. A v button and save by pressing button 3 This function is to set the maintaining time of the first program When you input 10 10 operation maintains for 10 hours and 10 minutes max 99 hours 59 minutes Set the time by pressing A Y button and save by pressing Page 24 Z Lab Companion button m 4 This function is to set the maintaining temperature of the first program 4 60 Set the temperature by pressing A Y button and save by pressing a button You can set the 9 step program by operating That is you can set time 2 and temperature 2 at program 2 and set the time 3 and temperature 3 at program3 and so on till program 9 You can input O to cancel the setting 18 Auto Tuning Perform Auto Tuning in order to get precise and rapid temperature control PID value is saved automatically after Auto Tuning lf temperature control seems to weak or there is a full of specimen inside the chamber Carry out Auto Tune at temperature that has frequently being used PERSONAL INCUBATOR H Ls Lt J PV AST gt HEAT OWON WiOFF _IO T 4 Set the desired temperature 2 Press button for a while 1 second then Auto Tune display is shown see a picture above and A T LED is turned on Page 25 Lab Companion 3 When you press button Run LED is turned on A T LED blinks and Auto Tune displays 4 Auto Tune time varies depending on the ambient environment When aut
4. Delete all set points Zoom in out Sin Zoom in or Zoom out Page 40 6 Display Display Panel W ON W OFF TEMP stant J ot ia e All the functions of display window are same as those of main display panel If communication via RS 232 between PC and main body is connected user can control main body with your PC at a distance 7 Pattern Program LabTracer C TestDataWBath1115_2 LTF O ioj xj File Comm Pattern View Unit Panel Informati N zlo la la alzi SIE ala al koll sa Graph T 75 The following window will be open when you click PRG icon or Pattern gt Pattern settings in menu Page 41 vi Lab Companion EA e SV pattern programming re Ai Pic 2 Pattern Program When you move a mouse and click a certain point like pic 3 a set temperature time and step number will display on the left side of window a EE B a 2 FA oY pattern programming Pic 3 SV Pattern after clicking a certain point of window If you want to edit the selected point Drag amp Drop the selected step blue color It is very convenient to use short keys when you want to change temperature and Page 42 Z A Lab Companion time because temperature can be adjusted by 1 degree and time can be adjusted by one minute 1 Short key f Increase temperature by 1 degree Decrease temperature by 1 degree lt Decrease time by 1 minute gt
5. Do not rebuild the equipment Z WARNING Do not use it for other purposes An electric shock or a mechanical trouble might be occurred from rebuilding or using it for other purposes 2 Characteristics 1 This equipment is a multi purpose low temperature incubator for biotechnology pharmacy medical science chemistry and biology It has applied CSL Custom Logical Safe Control System that Jeio Tech originally developed for the convenience in use and the safety 2 CLS Control System means Control system which has a logical safety device specialized for an individual model Laboratory must have a thermal Page 5 Lab Companion Z safety because there are a lot of inflammable reagents This system is the highest safety control device patent applied and makes the equipment suitable for this kind of environment 3 The unit can be connected to PC using the attached communication port It is also possible to monitor and set the values using the Lab Tracer CD included 4 The unit is designed to stop the heater and blower in order to protect the user from heat when the door is opened during the operation 5 The unit has insulation for high temperature in the outside of the inner chamber and inside of the door and also has a chamber silicone door for high temperature Therefore insulation is perfect and the level of losing heat is very low 6 The inner glass door is good for insulation and observation 7
6. The door attached a magnetic packing has effects on impact relief and double secrecy 8 Circulated fan of a cross type is attached for the distribution of uniform temperature and creates an indirect air circulation 9 Safety circuit has built in to protect the equipment from an excess current and an overheating 10 Development of exclusive controller allows the user to control the speed 3 steps of the inner fan and defrosting period and time 9 Step Programmed Control allows the user to set and operate 9 different temperature and time max 99 hours 59 minutes Operation is possible to be repeated from once to 999 rounds 11 Program Operation Temp o Ts Ts Ta Te Ta T Tr Ts ia H H H H a H H a Hr Ha Hs Hour h Page 6 Lab Companion 3 Installation 1 Notice while installation 1 Please check the following contents after opening the package Main body 1 set Shelf 1 ea Shelf maintenance clip 4ea 2 Be careful not to get the item shocked while transportation Z CAUTION 3 This unit will work correctly on a proper power supply Please check whether the This item should be protected from outer shock power supply and ID Plate information are the same User must use the power supply connected to earth and power cord must be connected to wall outlet supplying ground point Connect the power properly with correct voltage phase WARNING and capacity Improper conne
7. good The surface is electrically polished therefore it has a beautiful view and a good anti corrosion 7 Blower Air from the heater or Cold sink is ventilated out of the chamber Indirect ventilation 8 Chamber Its made of stainless steel There are a blower a heater a temp sensor and a temp regulator inside of the chamber 9 Water Level Viewer A This is for easy water level checking 10 Main Power Switch Circuit Protector This is for Power On Off and protects the instrument from sudden excess current 11 Temperature controller This has a micro processor CPU which has a digital PID auto tuning function It also has the highest level of safety control system such as a temperature compensational function for temperature sensor and a heating volume controller 12 Over temp limit If a heater temperature rises higher than a set temperature the unit cuts the power of the temperature controller makes the over temperature LED blink and warns with a beep sound To resume the operation please turn the knob clockwise to set about 15 higher than a set temperature and press a Start Stop switch ones Then check whether the run LED of temperature controller is on 13 Communication port Page 15 Z 7 Lab Companion User can monitor and control this unit by PC Data print out through PC printer is also available The unit can be connected to PC s com1 and com2 port through a RS 232C protocol cable 14 Door Ha
8. is activated and it is completely turned on when the timer is on stand by 3 Heater LED It shows whether heating function is on 4 Wait Off Timer LED This LED shows when the unit is on a timed off function The LED blinks when the timer is activated and is completely turned on when the timer is on stand by 5 Over Temp limit LED If the heater temperature rises higher than set temperature it cuts the power of the temperature controller makes the over temperature LED blink and an alarming beep rings To resume the operation please turn the knob about 15 higher than a set temperature and press a Start Stop switch once Then check whether the run led of temperature is on 6 Temp Button This button is for temperature setting 7 Timer Button This button is for timer setting 8 Up Button This button is for increasing the set value 9 Down Button This button is for decreasing the set value 10 Enter Button This button is for saving value after changing the set value 11 Lock Button Page 18 Z Lab Companion This button is for setting and releasing the lock function and using pattern function in the Lab Tracer Press a lock button for a while about 1 second then lock function is set with a beep sound Press a lock button for a while about 1 second again then lock function is released with a beep sound When a lock function is activated the unit operates only with a start icon after setti
9. on the PV panel contact your local dealer Without any signal as not A strong high frequency noise Move or relocate the equipment in described above or touching affected in the power supply question the keyboard all the system Check if high frequency has been broken down welder or high frequency sawing machine massive SCR controllers have been installed in the vicinity of the unit Decreasing time for Check if use on proper Use on correct voltage for the best temperature top long voltage performance and life of the unit In case full of dust in the filter Take out the filter and clean it Check if water pump is Stop the operation immediately pumping contact your local dealer Check if rear radiator fan is rotating Check if the circulation fan in the chamber is rotating Please turn the power switch off immediately if the unit does not function properly AN WARNING Do not attempt to disassemble the unit by yourself because replacement and adjustment of parts require advanced skill and specialized equipment Please contact Jeio Tech or your local dealer in the event of request for repairs Handling the electric parts for the unit should be serviced only by the qualified persons Replacement parts should be sourced only by on standard specification Damage caused by an abnormal operation can not be covered with the Warranty Page 29 ys 9 Warranty 1 General The product is warra
10. 11 Teraperdiure Coniroler 12 Over Temp Limi 10 Moln Power swier It Dost C2 inner Door 3 IMagneile Packing ot a oy a E aa fay inner Door Laten 3 Weter Level dewer A See te aaa ay E Shef 5 Shelf Level Adjuster 13 Communication Port 14 Door Handle 8 Mon Powercord C17 Filter 16 Waler Level Wewer B 15 Radtater Coalinga Fan Page 13 vi Lab Companion ILP 11 11 Temperature Controllaf12 Over Temp Lim 1 Goor 2 inoesr Doar Lon nme is ogis Poaching ap 14 Door Handle a Mambe 7T Bigve BY ShatlS Shaf Level Adpealer 44 D Loich M3 Cammunicetign Por 4 tener Door Loic OG Mola Power Saleh ss ee p r m rm m r l _ i ie 16 Mow Power Cord 15 Rodlaier Coolng Fon M19 Wole Supplement Door 6 Waler Leva Vlewer 1 Door For using adiabatic material we removed dewdrops on the surface of the door 2 Inner Door User can observe the inside of the chamber through this transparent and made of reinforced glass inner door 3 Magnetic packing It absorbs the impact and protects the samples doubly when door opens and closes Page 14 Z Lab Companion 4 Inner door latch Fixing Inner door 5 Shelf Level adjuster Shelf level is easily adjustable by the size of samples 6 Shelf Its made of stainless steel wire Its easy to clean and ventilation is
11. OPERATION MANUAL vi Lab Companion LOW TEMP INCUBATOR Model ILP 01 11 Manual No OOHAA0001170 Version 5 0 This operation manual describes the important subjects to maintain the product s functions and to use it safely Especially be sure to read lt Safety Precaution gt carefully before you use this equipment Please keep this manual close to the equipment to use it after reading through it once Please place it where the new user can find it easily for the safety use when you hand over or lend the equipment to others aa TECH Page 1 iS Thank you for purchasing Jeio Tech s product This operation manual forms a definition of warning marks according to the level of Lab Companion importance and danger in order to use the product safely and correctly and prevent the users from accidents or injuries Hence please use the product in accordance with the instructions Safety Notice 1 Caution This product can cause a big accident in case of improper use of inflammable and combustible solvents in the chamber Also operation in the high temperature might cause a mechanical trouble and quality deterioration due to the function and the characteristic of the product Safety Precautions Danger means that the user may have A N DANGER serious damage and even die by improper handling on this unit Warning means that the user may ANWAR N N 5 have serious damage by improper
12. Or click Browse and select another folder Space needed 7 159K Bytes Browse River Logics Cancel Page 32 Z Lab Companion 3 Click Install to start installation 4 Lab Tracer icon will be created on the desktop after successful installation 5 To start Lab Tracer double click the icon Standard Recommend Beyond Microsoft Windows 98 Microsoft Windows 2000 XP CPU Beyond P II 233 CPU Beyond P III 300 RAM Beyond 32M Byte RAM Beyond 64M Byte Caution If Windows 95 or 98 OS system is installed measured time can have some errors Page 33 Lab Companion 13 How to Use Lab Tracer 1 Connection for communication Click Comm Connect and your PC and equipment will be connected to RS 232 communication In case of no connection click Comm Port and try other ports Fra Lab Tracer i all xl Ae om atten Yew Unt Perel biura aj alaj malaj alal 212 2 12 E S ees Lt Fla I On Line displays on the bottom of the software once communication is connected successfully The window consists of 2 separate windows Window on the top displays set temperatures and actual temperatures and window on the bottom displays output value of heating in a graph mode Page 34 vi Lab Companion 2 View 2 1 If you click View Parameter window displays actual temperatures set temperatures and output of heating by a graph and figures 2 2 If you click View Status additional s
13. Tien button Timer On Timer Off Timer is shown on PV and time is shown on SV Set the time by pressing A v button and save and finish by pressing button 2 After the setting is done a beep sound and W ON LED inform that setting has been completed Page 21 JIS Z Lab Companion SAS 3 Press button one more time You can set the wait off timer Set the time by pressing a v button and save and finish by pressing B button 4 After the setting is done a beep sound and W OFF LED inform that setting has been completed 5 The function of Timer is shown below Temperature Time Wait on Timer Wait off Timer Page 22 Z Lab Companion Wait On Timer The unit begins to work after the time programmed on Wait On Timer passes The maximum of adjustable value is 99 hrs 59 min and the minimum is 1min Wait Off Timer The unit stops after the time programmed on Wait Off Timer passes since SV and PV meet Combination of Wait On Timer amp Wait Off Timer The unit works as a picture above 6 Timer set deactivation Press men button in order to deactivate timer function Both on off timer In order to cancel only one of the timers set the value of the timer to 0 15 Additional Function of mmea Button Auto Run When you press rian button three times from the initial state following function operates Hrun no PV This is to s
14. ction causes a fire or an electric shock Use the grounded power supply WARNING Ungrounded power can give a serious damage to the equipment and the user For the safety do not connect a grounding conductor to the gas and water pipes 4 Outlet should be located near the unit and shall be easily accessible Z WARNING 5 Please install the unit in the flat place where prevents vibration and shock Do not use an ejected socket or a double tap Cable damages or a fire can occur by an excess current 6 Please avoid heat sources and direct sun light and locate the unit where ambient temperature range is 5 C 40 C and relative humidity is lower than 80 7 Please do not let moisture organic solvents dust and corrosive gas enter into the control box 8 Please don t install the unit in the dangerous place where there are flammable gases explosive materials and organic solvents such as acetone and Page Lab Companion Z methylene chloride 9 Please secure enough space for installation because the door opens 180 to the left 10 Please do not install the unit near by the machines generating a strong high frequency noise 2 How to fill water into water tank ILP 01 1 Filter 2 Water Level Viewer 3 Funnel Depart from the main body Water supplying into the funnel 1 Remove the screws on the rear fan filter by a screw driver when it s off operation take out the same from the unit fill
15. d ILP 01 a 400 X 535 X 385 Consult with the qualified body Person who can handle ILP 11 Oos 430 X 700 X 620 industrial waste Page 30 vi Lab Companion 11 Specification Chamber volume Temperature 5C to 40 C Permissible Maximum relative humidity 80 Altitude up to 2 000m 3C 60C at room temperature 20 C 0 1 C at 20 C 0 5C at20 environmental condition Range Accuracy gt Uniformity gt Temperature Controller Digital PID auto tuning Pt 100 Q Pt 100 Q Wait on time Wait off time Sensor type Timer Max 99hr 59min Min 1min Internal Stainless steel 0 6t External Steel 0 8t powder coating Shelves Stainless steel wire electro polished Thermoelectric element Thermoelectric element Refrigerator Material 48W X 2 48W X 4 Heater Cartridge Fin type 300W way Beer Electric requirements weighted Page 31 Lab Companion 12 Install Lab Tracer 1 Insert an installation CD and then the software starts installation automatically In case of no automatic running run SETUP exe file in CD m Fabi racer II 2 2 Click Next button to choose destination of installation Default folder recommended A Installation of LabTracer Select install folder LabTracer will be installed to follawing folder Click lt Install gt ta begin installation to following folder To install ta a different folder Either enter install path
16. eceeeeeeeeeeceeseeeaeeeeees 2 8 Dealing with Abnormal Condition cccecccecceccceeceeeeeeeeeeeeeeeaeeeees 28 SNN Y sib crepes st acde seh E OE 30 WO DISUSCTPFOGUGIS accmocedccensecstrceassecenenagreseccous sande nseeaeees ain seasatacan 30 TTS SCCINCAUOMS E a E 31 TZN aE a D PTO ANI szrini prenra a AE 32 13 How to use Lab Trace cisscriroicriciriicntsiurrrine raia OF Page 4 Z Lab Companion 1 For Safe Operation Be fully aware of the safety since this product does not have a hydrostat A N DANGER Do not put inflammable substances like organic solvents In case of operation for the high temperature the samples might ignite and explode from vaporization in the chamber Explosive materials are acetic acid ester nitro compound and etc Inflammable materials are inorganic peroxides acetates organic solvents and etc This equipment does not have a hydrostat 2 Application and Features 1 Purpose 1 Low temperature incubator is suitable for preservation of culture ground culture fluid and seeds 0C 4 degeneration test of grain and meat 10 C 14 C cultivation of microbes and plants COD BOD measurement 20 C 257 suspension of enzyme reaction preservation of enzyme solution and desalting of enzyme extract 2 It also can be used for high temperature tests 55C 60 C such as environmental variation tests of cultivation grease and pigment of high temperature microbes and bacteria
17. elect the machine mode in case of a power failure This function operates the equipment automatically after a power recovery in case of a block out during operation or a power cut by mistakes When the user sets to Yes the equipment operates the moment the power is recovered 16 Additional Function of Button Fan speed control When you press mm button four times from the initial state following function operates Page 23 O This function is to control the speed of inner circulating fan It is recommended to be set as a third stage since slow speed does not contribute the temperature distribution 0 to 3 stage is possible 17 Additional Function of rin Button Programmed Control 9 Step Programmed Control allows the user to set and operate 9 different temperature and time max 99 hours 59 minutes Operation is possible to be repeated from once to 200 rounds When you press mmer button five times from the initial state following function operates 4 It indicates the entire repetitive number of program Loop 100 means that it will operate 100 times Set the number by pressing A Y button and save by pressing m button The next function operates when you input more than 1 Input O when you do not want to operate this program 2 SEg L is a segment logic that divides the section s boundary When you input 3 here third program is repeated from second repetition Set the section by pressing
18. eparated window appears below the window showing actual temperatures and set temperatures Operating Auto Tune Program Over Temp Level and etc display on this window Labtec Gey TeeGate Baht t1s 2 TF b aloj aj Be gemm Patten we Ut Eae o ABN zle aigi S aa 221217102 a OI 220 Tins MiM 4 ee Sia PM CAPS ge ONT Lime The picture above is a monitoring window after choosing Status and Parameter in View menu Page 35 Lab Companion fe Lal Trae DE Tea a S LTF Fe Comm Patter Yea Unk Pane nio AB zle ala sla alaj maia ala 2121712 of of G 1S 7l C OV Ch CO HHM o WMM 0 AM SMH C o w AEN 140 PM Cu EE CMT Lee User can monitor operating process through three divided windows Graph Parameter Status 2 2 1 Graph displays Actual temperatures Red line and set temperatures Blue line on the top of the graph windows 2 2 2 Status displays 1 Operating represents the unit is running If blue line is high the unit is on operating If blue line is low the unit is off 2 Auto Tune displays whether the unit performs Auto Tuning or not 3 Program displays whether the unit is in programmable mode or not 4 Over Temp displays whether the unit is overheated or not 5 Water Low displays whether water level is high or low Page 36 vi Lab Companion If water level is low blue line is low position Low position is under the normal condi
19. ew the same appearance of displayed panel of unit pops up and you can control the unit by the pop up window 17 Set Pattern of Program Run Set Pattern of Program Run and makes unit in a programmable operation Maximum number of pattern is 100 during 99 hours 18 Program Run Program Run must be set in the main unit AN CAUTION Program function can be controlled only by PC 19 22 Zoom In Out 23 24 Icons to convert the unit of temperature from to F or vice versa Note Unit of temperature of main body is not changed even though you convert the unit from Lab Tracer To change the unit of temperature of main body you must change it using the controller in main body 25 To erase the graph Page 38 Lab Companion 5 Preview and abu ie yoma Fear oe perf Sae adaa an ead 24 76 T FN T Pent te screnn P Cumar pagi F Selaca pupes Fram T Tel Braw 50 00 T 0 00 PY pit Interes Ii E mius f Pont at ual ral oon OT EEE When print at equal intervals is checked PV and SV are printed in a regular interval like the preview above If user wants to check a certain point move curser to the point Green line with PV and SV will be printed on the copies see above e gt 31 a 2 elo Page 39 vi Lab Companion Last Point Delete Delete the last set point All Point Delete
20. hort circuit power source contact your local dealer Even when the unit is turned It is likely that power cord is Turn Power switch on fully plug in on the display does not not fully connected or plugged power consent appear on the panel Power switch broken Stop the operation immediately Temperature controller broken contact your local dealer If Run LED is turning off press The temperature can not be Check whether RUN LED is increased or decreased on or off Start Stop The temperature can not be Err S message displayed Stop the operation immediately Err S message Perform Auto Tune displayed on the PV panel a In case operation stopped by Check the followings Rotate the red knob of the Over the Over temp limit 1 if OM LED is turning temp limit clockwise to the on in red position which is greater 15 than 2 if there is beep sound that of PV present value constantly Press Start Stop once more red light of O T LED and beep sound will disappear simultaneously 2 Press Start Stop once more the unit will restart with RUN LED and Heater LED lighting up Page 28 Z Lab Companion The unit does not operate with Check if the water level in tank Fill the tank with water according to beep sound constantly is in low position the manual instruction on water supplement When Err S message Stop the operation immediately displayed
21. le shelf supporter be cautious of bending the shelf supporter not to injury your 3 After finishing the fixation of 4 ea shelf supporters at the same height put the Shelf on the shelf Supporter Make sure that its horizontal level is correct and re fixate the shelf supporter if it s not correct 1 Shelf an 2 Shelf supporter shelf support and shelf setting Page 11 7 Lab Companion vi 4 Precaution 1 Please do not touch the power cord and electric parts with wet hands 2 Please do not put explosive and flammable chemicals Alcohol Benzene and etc into the incubator 3 The samples inside of the unit are very hot when the unit operates and for a while after it stops Please put on safety gloves when you touch samples 4 Please do not place flammable materials near by the unit 5 Please do not pour water on the unit directly when you clean it 6 Please do not put conductive and flammable materials through ventilation or power supply port It is dangerous and might cause fire and electric shock 7 Circuit and electric components used in this unit are developed by Jeiotech Please do not try to repair by yourself Incorrect combination of electric parts may cause a fire You must ask an official Jeiotech dealer or a distributor in your region DANCGER Do not put explosive and flammable materials inside of the chamber Page 12 vi Lab Companion 5 Name of the each part ILP 01
22. ndle This is for opening and closing the door 15 Radiator cooling fan This is a fan for cooling the Radiator 16 Water Level Viewer B This is for checking Water level in the tank and water supply 17 Filter This is for filtering dust from the water supplied into the radiator The filter can be attached and detached easily for cleaning Detach the filter when supplying water in the tank ILP 01 only 18 Main Power Code This is for connecting power code to rating voltage 19 Water Supplement Door Water supplying hole can be seen when opening the door which is fixed by magnetic ILP 11 only Page 16 Z Lab Companion 6 Operating Controller 1 Characteristics 1 CLS Control System carries out temperature control of equipment and heating control in the Main CPU where precise PID algorithm is possible All actions for safety are conducted by a selective functional Logic IC which is installed separately This is designed to conduct safety performance against any electric and electronic shock on the unit 2 CLS Control System shuts down all 2 phase power supply to each part immediately and informs user instability by audible and visual device and then it keeps in safety mode until all instability conditions are removed 3 CLS Control System has wait on off timer function for the user s convenience The function starts or stops the operation after the set time 4 CLS Control System gives user two choices when
23. ng the pattern in the Lab Tracer 12 Auto Tune Button The auto tune begins if you press this button for 1 second 13 Start Stop Button This button is for start stop of unit and for resuming operation after removing some unstable factors when operation is terminated 14 Run LED This LED indicates Work Stop state of unit It turns on when the unit runs and turns off when the unit stops 15 PRO LED This LED indicates whether the operation is in program or normal status The LED blinks when the operation is in program status and it turned off when the operation is in normal status 16 SV Display This display is for showing set temperatures and remaining time when the timer function is activated 17 PV Display This display is for showing present temperatures 12 Temperature Setting Method 1 Press button A set temperature value SV blinks This means you can change the set value D Press A v button to change the digit number and then press m button when you save the value 3 It goes back to the previous state without saving if you don t touch any button for 10 seconds Page 19 Z jx Lab Companion 4 Press button again when SV display blinks then following additional functions will be activated PERSONAL O RUN INCUBATOR a goo SV O PROGRAM O AIT HEAT Owion Cues a v m 13 Additional Function of Button nF Jog This is saving and loading function of set l sv temperatu
24. nted to be free from defects in material and workmanship under normal use and maintenance for a period of 1 year on all components The warranty period begins on the date of original installation to the original owner For the fast and correct repair times please provide complete details of any a 7S Lab Companion problem encountered as the followings Original dated proof of purchase Serial number on the name plate of the product Detailed description of the defective Position symptom etc Operating environment of the product 2 Conditions of the warranty The limited warranty shall not apply to damage or defect resulting from User s misuse of the product or negligent use not properly installed stored and cared by user Abuse improper use modification change or alteration of the product Damage as a result of floods winds fires lightning accidents abnormal voltage conditions or other conditions beyond the control of the company the operation beyond rated capacity operation of electrical components at voltages other than specified in the rating plate or lack of proper maintenance or service in accordance with User s information manual 10 Disuse product In the event of disusing the product or part you should comply with the designated method by the company as follows Disuse method for the main parts of the product Description Model T W Kg Outer Dimension mm Disuse metho
25. o tuning is done the light on LED goes off and the unit operates with the set temperature When you press a button for 1 second during operation auto tune display is shown and is set A CAUTION Please do not put the specimen inside of the unit when the Auto Tune is on operation 19 Lock Function PERSONAL INCUBATOR Gree 5 GAT O HEAT OWON WIOFF 0T 1 This button is for setting and releasing the lock function and using pattern function in the Lab Tracer When you press button for approximately 3 seconds display shows con P with a beep sound When a lock function is activated the unit operates only with a start icon after setting the pattern in the Lab Tracer Page 26 Z Lab Companion 7 Maintenance and Cleaning Pull out a power plug from the outlet before the CAUTION cleaning and inspection Turn off the main power switch and pull out the power plug before the cleaning and inspection An electronic shock or damages on the unit might occur 1 When you clean the unit pull out the power cord from the outlet and wipe it with a soft and dry cloth Wipe the dirt with a cloth containing the solvents that have a low boiling point methanol and ethanol 2 Do not use acid solvents benzene sharp materials soapy water washing solvents and hot water They can cause the damage or discoloration of the unit Parts with rubber and plastic can be changed degenerated or discolored Wipe the unit with a dry clo
26. r supplying into the funnel 2 Remove the stopper of a funnel fill water into the water tank while checking the water level through the water level viewer Preferable distilled water preventing from occurring corrosion for the extension of the expected life soan of the product water tank 3 42 in full capacity and its alarm start to buzz when its water level is lower than the 1 42 Page 9 is and stopped the operation at the same time Ensure that water tank should be filled in full capacity in the original installation in order to fully load the water hose and radiator Z Lab Companion 3 Put the stopper of a funnel when water tank fully filled Put the main switch on select the required temperature start the operation for a minute Do not touch the unit with wet hands preventing from a risk of electric shock 4 Fill water again into the water tank in case its water level is lower than the indicating point When it s off operation After finishing the filling water put the stopper on a funnel Re install a fan filter on the unit 5 Check if its on normal operation without any trouble when it s switching on Page 10 Z Lab Companion 3 How to fixate the shelf 1 check which is the upper end and lower end of the shelf supporter 2 Insert the upper end of the shelf supporter into the hole inside of the chamber and next insert the lower end of the same into the hole at one step down by bending the who
27. res PV Setting is as follows Press A Y button to change the temperature Suc 400 e PV and press button to save Set temperature is saved in the memory and a current set temperature is changed Sv 2 Sv 3 can be set using the same method Sv1 Sv2 Sv3 are _ shown in order when you press ren button repeatedly If you press it one more time it becomes the function to change a unit of a temperature oO This is a function to change the unit of Lind E E sv temperature value Initial display is C and it can be varied and F by pressing 4 Button Page 20 vi Lab Companion Press button again to move on to the next function 3 By buttoning 6 times next function is displayed This is a function of calibrating temp errors Corrected value is displayed on PV display Next function is by buttoning A and Y Pv is displayed on the SV display and the PV can be set as the same PV of thermometer Set values by buttoning A and v and store by buttoning a You can see AJST on the left handed display and see SV on the right handed display which is displaying present value for temperature This is to adjust the value which is corrected by a accurate thermometer Using A v button finish the process after all setting 14 Timer Setting Method PERSONAL L RUN n onk w OOD loy Ee OAT gt HEAT a vy m OWON O WIODEE Press
28. th after using a natural detergent Then dry it completely Use proper methods and materials for cleaning and A N CAUTION inspection Do not pour the water directly or use polishing powder kerosene acid on the unit An electronic shock or damages on the unit might occur 3 Use appropriate safety gloves for harmful chemicals and a safety mask for harmful gasses in the event of cleaning accidental chemical spills from the unit 4 Do not pour the water directly on the equipment especially control panel Short circuit can be occurred 5 If the user tries to clean this unit with other method not mentioned on this manual please contact us in order not to damage the unit 6 Only authorized technician can treat the electronic parts inside of the equipment 7 Use only the original parts for replacing Do not disassemble the equipment WARNING An electronic shock or an injury might occur when you disassemble since there are parts where high voltage flows and high temperature locates inside of the equipment Page 2 Lab Companion 8 Dealing with abnormal condition If the unit does not work Use the following procedure 1 check if use on proper voltage or current 2 check if RUN LED is lighting up If it s turned off press for restart 3 Check if the power supplied actions Even when the unit is turned An electric leakage ora If the problem persists remove the on it turns off immediately S
29. the units operation is terminated by a power failure and then the power recovers One is a resume of the unit s operation Another one is to keep the unit in standstill 5 CLS Control System is composed that feeble electric current streams down to only 5V 10mA at a point of contact of a used safety device There is no damage of a point of contact in use of a long time So the durability is very long After it stops the control of the Thyristor which controls electric current stream of the heater that uses a large electric current when a safety device is operated it shuts down the power through Magnet Switch s disconnection of a point of contact It prevents the point of contact from damaging and a noise revelation of a power switch It enforced with the mentioned objection order above when an operation of equipment starts and it also prevents the point of contact from damaging and a noise revelation of Magnet Switch 2 Name and Operation t O keka INCUBATOR a A py YOu SV ci 2 i N O HEAT o W OFF O T a v m SO 9 Pan Page 17 7 Lab Companion vi Main CPU of this unit has certified S W which allows Digital PID Auto tuning The unit has a temperature deviation correction function for the Pt 10002 sensor and the highest safety level of control system 1 Auto Tune LED It blinks during auto tuning 2 Wait On Timer LED This LED shows when the unit is on a timed on function The LED blinks when the timer
30. tion 6 Cooling displays whether compressor works or not 2 2 3 Parameter displays 1 PV is an actual present temperature 2 SV is a set temperature 3 Heat is an output value of heating element 4 Run Time indicates operating time after you press E button 5 Wait On Timer Wait Off Timer displays remaining time from a set time 6 Power Frequency displays frequency of a current power 3 Menu icon FI zele 2l 1 2 3 4 5 6 7 1 File Open Ctrl O To open saved graph 2 File Save Ctrl S To save proceeding graph 3 Connect Ctrl C To connect unit and PC via RS 232 communication 4 Disconnect Ctrl D To disconnect RS 232 communication 5 Exit Ctrl X To terminate Lab Tracer 6 Print Ctrl P To print saved graph or proceeding graph refer to p30 7 Preview adaa 10 11 12 13 8 9 To preview before printing 8 9 Scroll icon To scroll graph Page 3 JR 10 11 Auto Trace On Off If you want to fix and monitor the end point of graph on the center of windows Click Auto Trace 12 13 Auto Span On Off Set Y axis temperature range of graph manually or automatically You can put US wap Companion values of range if you choose manual ile aa J a 17 18 19 20 21 22 24 25 14 To display Status window Ctrl T 15 To display Parameter window Ctrl R 16 Panel View When you click Panel Vi
31. tion and control option programmed f you check Deleting the previous data option and press a start icon all the previous data will be erased Please be cautious x Caution Maximum operating time is 99 hours f you program total working time over 99 hours the unit does not operate in program Mode Especially be cautious when you program a pattern repetition Please be aware of specification about program time and temperature f you program the pattern that exceeds equipment capacity the unit can not work properly Page 44 Z Lab Companion Page 45 vi Lab Companion Page 46 Z Lab Companion Page 4
32. water by using a funnel 2 Remove the stopper of a funnel fill water into the water tank while checking the water level through the water level viewer Preferable distilled water preventing from occurring corrosion for the extension of the expected life span of the product water tank 3 42 in full capacity and its alarm starts to buzz when its water level is lower than the 1 42 and stopped the operation at the same time Ensure that water tank should be filled in full capacity at the original installation in order to fully load the water inside of the hose and radiator Page 8 Z Lab Companion 3 Put the stopper on a funnel when water tank fully filled Put the main switch on select the required temperature start the operation for a minute Do not touch the unit with wet hands preventing from a risk of electric shock 4 Fill water again into the water tank in case its water level is lower than the indicating point When it s off operation After finishing the filling water put the stopper on a funnel Re install a fan filter on the unit 5 Check if it s on normal operation without any trouble when it s switching on ILP 11 1 Pull out the water supplement door in the rear position of the unit when it s off operation Try to pull it out over certain strength because it s fixed with magnetic attraction EF 3 p 3 Funnel i r ipa A G 1 Water Supplement Door 2 Water Level Viewer Wate