Home

BioProg Enhanced User`s Manual

image

Contents

1. FinalFreq Step Time On from 1 second till to 59 minutes and 59 seconds it is the time during which there is voltage on output it is the time during which there is voltage on output Step Time Off from 1 second till to 59 minutes and 59 seconds it is the pause time no output before the next step For a SQUARE Key gt gt Uy The Start Frequency from 000 001 Hz till to 999 999 Hz it is the lower frequency in the step The Final Frequency from 000 001 Hz till to 999 999 Hz the Final Frequency cannot be less than the Start Frequency it is the upper frequency in the step when StartFreq and FinalFreq are equal there is no sweep and a Static frequency will be output Duty Cycle from 25 till to 50 it is the percentage of the time there is a voltage in output with respect to the period of the wave Voltage Out from 8V till to 15V it is the output voltage Sweep Time from 0 till to 999 seconds it is for the frequency step used to increment the output frequency every tenth of second when sweeping the frequency from Freq Min to Freq Max and back to Min in Hz It will be preloaded with 0 when StartFreg FinalFreq Step Time On from 1 second till to 59 minutes and 59 seconds it is the time during which there is voltage on output it is the time during which there is voltage on output Step Time Off from 1 second till to 59 minutes and 59 seconds it is the pause time no output before the next step it is the pause tim
2. devices LCD Super Zapper and Full Gamma Generator need the BioxTENSion accessory to generate this waveshape and is reserved for the TENS waveshape Transcutaneous Electric Nerve Stimulation By convention the key color is light gray e A New Zapper Key this key type is for the LCD Super Zapper device and is also compatible with the Full Gamma Generator and the Biostream Twin Module devices By convention the key color is amber Click on the button of the chosen SmartKey type the next window is in this case we have chosen a Sine Key BioProg Enhanced 2 0 KE Sine Key Command Sine Key NoName Save Sine Key Key Name NoName Step Frequency Time On j Te Of Offset Voltage Sweep Tus i Save Sine Key As Write Sine Key Compare Sine Key Print Sine Key Fig 7 General Window to define a SmartKey Define each step of the program to create Your SmartKey click on the New Step button to create the first step the next window is BioProg Enhanced 2 0 Sine Key Command Sine Key NoName EDITED Save Sine Key Key Name NoName Step Frequency Time On Time Off Offset Voltage Sweep Time Save Sine Key As 1 1 1Hz 00 01 00 01 1V 5V Os Write Sine Key Compare Sine Key Print Sine Key Fig 8 Creation of the first step Page 9 of 11 Click on the line of the step and click the Edit Step button to define the parameters of this step the next window is BioProg E
3. less than the Start Frequency if you want a static not sweeped frequency enter the same frequency under Start and Final Voltage Out from 8v till to 15V it is the output voltage gt Sweep Time from 0 till to 60 seconds it is the time it takes to the frequency to increase from StartFreq to FinalFreq then return back to StartFreq gt Step Time On from 1 till to 59 minutes and 59 seconds it is the time during which there is voltage on output gt Step Time Off from 1 till to 59 minutes and 59 seconds it is the pause time no output before the next step Click and drag on the potentiometer the blue knob to modify the parameter in the clockwise sense to increase it and in the anticlockwise sense to decrease it You will see to change the parameter in its proper box When You have completed to define each parameter click on the Done button to confirm Otherwise click the Cancel button to null the definition and go back to the previous window It is possible also to e Remove Step click on the line of the step and click on the proper button to remove it e Move Up click on the line of the step and click on the proper button to move up it e Move down click on the line of the step and click on the proper button to move down it To define an other Step click New Step button and continue the procedure like described above until the last Step that You want the maximum quantity of Step is 16 It
4. BioProg Enhanced User s Manual INDEX t ORO WON is sete a se ae cps chee nectar ante sec eee ee ce paces eanacc eas E ee seaeseemaeame ces 2 TN GCoOpy Protech N sor E ic eesweecsnmnesaatvenencseaseo meskes 2 2 INSanna E E E E Ee 2 Ay SOUL ALO TENS Lea ACL ON een N E E AE E E E E EER A EERE E E 2 2 1 1 users Manta lorrin A A EERE E E AAEE E ENR RE E 3 2 1 2 Install BioProg Enhanced software sassssnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn 3 22 ACUIVaONMOLICENS Eeri E E A EEA e E AE A OE EE ERE 5 23 Sellal portSel cton ANG COCK crsa E E AE A EE A EE EAA RA ER 6 3 Starting th SOMW ales connus uni n a e E 8 a New Blank Key Command cssisisSeirsana onna e a aa aaraa aaea Ea aa aSa 8 9 OPE TOM TNS Commands ces rca Sane caer eee ee eee Geese 11 Trademarks Adobe Acrobat Reader is a trademark or registered trade mark of Adobe Systems Inc Windows is a trademark or registered trade mark of Microsoft Corporation Page 1 of 11 1 Foreword The BioProg Enhanced is a software to program Smart Keys from a PC with an User Interface easier than what is available on the Full Gamma Generator and the Biostream Twin Module devices It can be used with a MonoProgrammer device or with the PC link available in the Biostream Twin Module This software runs on a PC under the Windows Operating System The software is supplied on a self installing CD The graphics shown in this manual may differ from those display
5. ction supplied by the installation procedure e See User s Manual click on this to preview this manual The software will open the Adobe Acrobat Reader and the Reader will turn to display this manual You can browse the manual as well as print it clicking on the printer icon When You have finished with the manual click the Back button of Your browser to return to the Fig 4 Manual related menu e Back click on this to return to the Installation main menu Fig 3 You may prefer to return clicking on the back button of your browser 2 1 2 Install BioProg Enhanced software We suggest to install first the driver for USB second the dot net framework 2 0 of Microsoft and then the software BioProg Enhanced Clicking on the nstall button in Fig 2 the following screen will be displayed Fig 4 Install Software Menu Page 3 of 11 Install Driver click on this to install the USB to Serial Port Driver Assuming You have clicked this choice the Windows operating system will display a warning the actual screen image depends on Windows version saying that You are going to download the file PL 23 3 Driver Installer exe from D If present click on Run application from current position then click the OK or the Open button Sometime Windows will tell you that Author cannot be determined because of the following problems Authenticode digital signature not found Disregard this message clicking on the OK button and fo
6. e no output before the next step For a TENS Key gt gt gt Frequency from 5Hz till to 150Hz Step Time On from 1 second till to 59 minutes and 59 seconds it is the time during which there is voltage on output it is the time during which there is voltage on output Step Time Off from 1 second till to 59 minutes and 59 seconds it is the pause time no output before the next step it is the pause time no output before the next step Pulse Width from 50 usec till to 200 usec it is the time each single pulse of the biphasic pulse lasts Page 10 of 11 gt Sweep Time from 0 till to 250 seconds it is the time the system waits before incrementing the pulse frequency of 1 Hz used by the device during the sweep the device goes from StartFreq to an upper frequency limit which depends on the Start Freq value as below e 25 Hz for starting frequencies less than 25 Hz e 70 Hz for starting frequencies less than 70 Hz e 150 Hz for starting frequencies less than 150 Hz gt Burst Time On from 1 second till to 250 seconds it is the time the voltage is outputted in the so called burst mode gt Burst Time Off from 0 till to 250 seconds it is the time during which there is no voltage on output in the so called burst mode Itis possible to flag the Continuous box e Fora ZAPPER Key gt Start Frequency from 28 KHz till to 999 5 KHz Final Frequency from 28 KHz till to 999 5 KHz the Final Frequency cannot be
7. ed by the PC depending on Windows Operating System version and settings 1 1 Copy Protection The software is copy protected During the software installation Your PC has to be connected to INTERNET to receive automatically the activation code that will enable Your license In case of damage on Your PC please contact info Ipselectronics it to restore Your license for one more installation In the email You must insert all the data requested by the software during the installation This service is not free furthermore it will be available for one time only IMPORTANT Do not install this software on a computer Knowing that the definitive computer You will be using is a different one 2 Installation ATTENTION Do not connect hardware before having successfully installed the software The hardware supplied with this product if requested may connected using an USB port of the computer Smart Key TE mom Pi USB Option USB cable 1m long User s PC C eE C M m USB A Smart Programmer Installation CD Fig 1 Components supplied with the Smart Key Programmer Hardware 2 1 Software installation Insert the supplied Installation CD into Your computer the installation procedure will automatically start The following screen will be displayed actual image may differ slightly depending on Windows version and settings Fig 2 Software installation main menu Page 2 of 11 The Manual button brings You i
8. ed to internet during this operation Click on BioProgEnhanced icon only for the first time it will appear the following panel Page 5 of 11 HioP rag Enhanced Uicense Acthation Wielerree ti HiewPens Enhanand 3 1 in coder to proceed you have to ecireste tee kenca The prechuen i wiy hal al airgne aed pores Actin Ai the adoman in thes form val bes keened reserned lcenca code hes code a labaed on CO coer Mare and Saar Akier tap Emal AGevnre Ween pour inieme correction AUbOma Act eiin yau have io ba connecled al ls lina yuu J pen Automatic Agimin All date sent ae erated bo enemas the bei ciy j Actovate umng enc ephe or mothe Bare Activa tha preerie pens a egret wath al k Fioraio needed by achyabon iie fe send you an actin sada Erie Aciiration Code Eat without Acimar Fill in all the data requested as in the below panel HioProp Enhanced Licanes Activation Weke ot ery E raed ZI Bn rader in arene poo Reese ha acirade His koe Tha fepordues a viipy hal aral eens El od feted are pares Aira Su thane om thet lon vl be heed doer eens code URTA Ses oie oo beet on LD rere hare nel Guman Wahai Adis wa Stanmore la Car Piste State lig E reel vihanig erana i Aisle ciag oun betel oiai Automatic dictate you hare bo ba Gores ai tha tine you tt une Aceon Al daa pend we enceppted to engue the best pequnty Acia tng lim belephors on molis Manual Atte stion the
9. eo e giochi 4 Controller disco Floppy 4 Controller IDE ATA ATAPI Controller USB Universal serial bus Mouse e altre periferiche di puntamento y Periferiche di sistema Y Porte COM e LPT Df Porta di comunicazione COM1 Df Porta di comunicazione COM2 F Porta stampante LPT1 F Prolific USB to Serial Bridge COM4 SB Processori B Schede di rete E8 Connessione di rete InteR PRO 100 5 NIC Fast Ethernet PCI Realtek RTL8139 Family E Schede video Schermi Page 6 of 11 Click on the BioProgEnhanced icon and on the button Settings Open Fiom Fie Pibg iani Gma Pid Hami 4 moma rar e selira Plog aneis Senai Pod Nubes 4 BioProg Enhanced Key Programmer Connect the progeanenet eet a key ard piatt Read Key Reed Key Before to click on the button Read Key put a Smart Key in the proper connector of the Smart Programmer tool and then click on the button Read Key it will appear a new panel shown below HioFrog Enhanced Key Programmer ADOOOADORODDOROOOONAMAAMMI MoProginhanced Ez If the hardware it is working and the port selected is corrected it will appear this message Test Completed In case of problems contact the service through email at info lpselectronics it Otherwise now you are ready to use the BioProg Enhanced software Page 7 of 11 3 Starting the software Click on the desktop icon BioProg Enhanced to star
10. is possible to modify a Step already defined in every time like it follows e Click on the line of the step e Click the Edit Step button e Modify the parameters e Click the Done button to confirm When You have finished to define a Key Sine Square TENS or ZAPPER You can e Write Key click on the proper button to store the program in a Key follow the suggested instructions e Compare Key click on the proper button to read a program stored in a Key follow the suggested instructions e Print Key click on the proper button to print the file of a program follow the suggested instructions After to have defined one Step at least in every time You can e Go back to the previous window clicking the Back button e Insert a name to the program in the proper area of Key Name e Save Key click on the proper button to save a program with a name or to save the modifies of a program already saved in a preferred folder e Save Key As click on the proper button to save a program with a name in a preferred folder 5 Open from file Command The Open from File Command allows to open a file already saved in a proper folder of Your PC The file type suffix used by the BioProg Enhanced Software are e skg LCD Super Zapper e ski Gamma Sine e skj Gamma Square e skh TENS Page 11 of 11
11. llow the instructions supplied by the installation procedure Install Software click on this to install the BioProg Enhanced software Assuming you have clicked this choice the Windows operating system will display a warning the actual screen image depends on Windows version Download del file Avviso di protezione Eseguire o salvare il file 1 ie Nome BioProgEnhancedSetup msi 1 a Tipo Pacchetto di Windows Installer 482 KB Da D file scaricati da Intemet possono essere utili ma questo tipo di file D pu danneggiare il computer Se l origine non considerata attendibile non eseguire o salvare il software Quali ischi si corono Click on Execute depending on windows version may be displayed the following panel Internet Explorer avviso di protezione Impossibile verificare l attendibilit dell autore Eseguire il software Nome BioProgEnhancedSetup msi Autore Autore sconosciuto Il file non dispone di una firma digitale valida che ne verifichi l autore Eseguire solo software proveniente da autori considerati attendibili Come determinare quale software esequire Click on Execute Button ie BioProgEnhanced Welcome to the BioProgEnhanced Setup Wizard E7 The installer will guide you through the steps required to install BioProgEnhanced on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this pr
12. n a menu in which You can install the program required to display and print this manual Adobe Acrobat Reader and preview the manual The nstall button brings You in a menu in which You install the driver for the USB to serial port converter and install the BioProg Enhanced software 2 1 1 User s Manual This manual is supplied in the Adobe Acrobat Reader pdf format In order to be able to display on Your screen any pdf file this manual included and eventually print it you must have the Adobe Acrobat Reader software installed on Your computer You may have this software already installed check the icons on Your desktop in this case You do not need to re install it unless You have an older version and You want to upgrade it Clicking on the Manual button in Fig 2 the following screen will be displayed This manual requires Adobe Acrobat Reader Fig 3 Manual related menu e Install Adobe Acrobat Reader click on this to install the software needed to view and print this manual as well as all pdf files You must click this choice if You do not have this software already installed in Your computer Assuming You have clicked this choice the Windows operating system will display a warning the actual screen image depends on Windows version saying that you are going to download the file AcroReader505 UK exe from D Click on Run application from current position then click the OK or the Open button Follow the instru
13. nhanced 2 0 Sine Key Command Sine Key sine_01 Step 2 Frequency Begin Step Time On Off Start frequency Hz 000 001 Time On 00 01 Te Fine Save Sine Key As ra nS x1000 ii 6 S A min S sec O Save Sine Key Write Sine Key Compare Sine Key Frequency End Final frequency Hz 000 001 Time Off 00 01 Print Sine Key Gee Fine l lt 00 8 al yn AA PRE min sec Offset Voltage Out Sweep Time 5 Voltage V 1 0 Voltage V 5 0 Seconds 000 Volt Second T Fig 9 Panel for define modify the parameters You can define For a SINE KEY gt gt Y The Start Frequency from 000 001 Hz till to 999 999 Hz it is the lower frequency in the step The Final Frequency from 000 001 Hz till to 999 999 Hz the Final Frequency cannot be less than the Start Frequency it is the upper frequency in the step when StartFreq and FinalFreq are equal there is no sweep and a Static frequency will be output The Offset from OV till to 4 5V it is for the displacement of the mean of the sine wave from the OV level When above 1V the wave ampliture limits are reset from 5 to 9V The Voltage Out from 5V till to 9 4V it is the output voltage The Sweep Time from 0 till to 999 seconds it is for the frequency step used to increment the output frequency every tenth of second when sweeping the frequency from StartFreq to FinalFreq and back to StartFreq It will be preloaded with O when StartFreg
14. ogram or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Click on Next button in BioProgEnhanced Select Installation Folder The installer will install BioProgEnhanced to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Programmi BioProgE nhanced Install BioProgEnhanced for yourself or for anyone who uses this computer Everyone Just me Page 4 of 11 Click on Next button iw BioProgEnhanced Confirm Installation The installer is ready to install BioProgEnhanced on your computer Click Next to start the installation Click on Next button iz BioProgEnhanced Installation Complete BioProgEnhanced has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Click on Close button The installation is finished To activate the software click on Start programs in the folder LPS You will find BioProgEnhanced icon If You like You can activate a connection directly onto desktop i Jeri documents Offer t Easge d Varren ana amp progres u bigad cums Gia T Wincor Lpa pa Eph moam A C Gads m ires f Lpp iS tec E ia G Fr Seppe Viale Oe 2 2 Activation of license Be sure to be connect
15. piecka ponte a ari dh all miana needed bs Aon pee hitad pou on aceon Gods Cre Actwahon Code Eat pathol dictation The license code is labeled on CD cover click before on the Manual Activation button a report will be plot onto PC where all the instruction for how to handle a manual activation are explained with all data filled in You can print this report and keep it in a safe place because you need this data in case of need to restore the license on a new PC for serious damage on the PC where BioProg Enhanced was installed Print the report and close the panel Now if you have connection to internet click on to Automatic Activation button the activation procedure is completely automatic A message will prompt that the activation is successfully done If you don t have internet follow the instruction on to report and when you get the activation code enter it clicking on the button Enter Activation Code 2 3 Serial port selection and check Be sure to have properly connected the Smart Key Programmer to your computer as shown in Fig 1 Click on Start Settings Control panel System Hardware Peripheral Management Com Port and see on witch com port is Profilic USB to Serial Bridge driver in the below example the COM4 was selected amp Gestione periferiche EEk File Azione Yisualizza amp R 4 4 NEWPACKAGING 4 Altre periferiche Porta seriale PCI Computer Controller audio vid
16. t The software will directly bring to the following window F BioProg Enhanced 2 0 EEk Commands New Blank Key Open From File CO Fig 5 Main Window The Commands are e New Blank Key to create and save a new SmartKey Sine Square TENS ZAPPER with the parameters decided by You e Open from file to open an already saved file a a SmartKey to modify and or write it e Setting to set and or test the Serial Port Number e Exit to close the Program 4 New Blank Key Command The New Blank Key Command is for create and define a new Smart Key Sine Square TENS or ZAPPER Clicking on the New Blank Key button the next window is BioProg Enhanced 2 0 New Blank Key New Sine Key New Square Key New Tens Key New Zapper Key Fig 6 Choice Menu for the type of SmartKey Page 8 of 11 Choose to create e A New Sine Key this key type is for the Full Gamma Generator and the Biostream Twin Module devices and is reserved for the sine waveshape sine wave with variable positive offset By convention the key color is violet e A New Square Key this key type is for the Full Gamma Generator and the Biostream Twin Module devices and is reserved for the Clark type waveshape square wave with fixed positive offset of 0 25V By convention the key color is green e A New TENS Key this key type is for the LCD Super Zapper Full Gamma Generator and the Biostream Twin Module

Download Pdf Manuals

image

Related Search

Related Contents

Ver Ficha Técnica  here  Polycom Soundpoint IP/ SoundStation IP Family SIP 3.1 User's Manual  1999 SID Rear Shock Owner`s Manual  Motorola SBG941 Modem User Manual  Sistemas de Frenos Antibloqueo Hidráulicos  Konfigurationshandbuch  Pour plus d`informations sur ce produit innovant c  Sharp LC-46LD264E 46" Full HD Black LED TV  