Home

CTB16PC - Light-O-Rama

image

Contents

1. 1 Preparing the Rubber Grommets Three large rubber grommets were removed from the plastic box earlier Use a knife to cut the pie shaped wedges in all the grommets Cut from the inside of the grommet towards the center The larger tube shaped grommet will be used for the AC power and the network connection cables You may 15 CTB16PC have trouble feeding a booted Cat e cable connector through the grommet You may want to slice the larger grommet along its top side so you can more easily insert the data cables later Connecting the Power Cord s 1 The strain relief grounding bracket should NOT be installed in the plastic box at this point Do all of the following wiring with the bracket outside the plastic box 2 Push the quick connect ends of the single or dual AC power cord s through the large tubular grommet The end of the grommet with the groove that fits into the case must be toward the quick connects Then feed the quick connect ends through the center cable clamp as shown on the previous page Tighten the cable clamp s screws 3 Divide the power pigtails into two groups of eight Use a Metallic Sharpie or cable labels to mark the sockets in one group 1 through 8 mark the second group 9 through 16 Use a black Sharpie to mark the quick connect on the black wire so that it corresponds with the marking on the socket 4 Push pigtails 1 8 through one of the sma
2. Jumpers for placement of the jumper AutoConfigure fails to find COM port If the COM port is not detected you can manually select it from the drop down list If you are not sure which COM port is the RS485 adapter and you have a USB adapter click start My Computer gt View System Information gt Hardware tab Device Manager button Click the in front of Ports COM amp LPT you will see USB Serial Port COMn this is the RS485 adapter Use the Manual Select drop down box to select that COM port If you are not sure which COM port is the RS485 adapter and you have a serial port RS485 adapter you will have to consult your PC s documentation it is normally COM1 COM2 or COMB You can try the 27 CTB16PC Unit ID assignment steps with each serial port in succession Hardware Utility Refresh Fails Use the procedure in the section Assigning a Unit ID to assign a unit ID to the controller If this has been done and Refresh still does not work try manually typing the controller number into the box to the right of the Refresh button Use the options in the Test Unit s Operation section of the Hardware Utility window to see if the controller can be controlled 28 CTB16PC Updating Controller Firmware Periodically Light O Rama will distribute new firmware for your CTB16PC If you believe you need updated firmware use the Hardware Utility do determine your current firmware version Us
3. This full function controller was designed with the Christmas lighting enthusiast in mind It is our most economical controller that sacrifices nothing in terms of the lighting effects With some manual assembly labor you will have a full function controller ready for use in a weather resistant plastic box The CTB16PC is one of the components in the Hobbyist line of Light O Rama LOR products It was designed for residential displays It is a microprocessor based intelligent controller that can perform a number of lighting effects including dimming fading shimmering and twinkling It can be daisy chained with any mix of LOR controllers up to the maximum of 240 controllers The CTB16PC must be used with the LOR Windows Showtime Software Suite This software allows you to configure and test this controller design your sequences sequences are lighting control command sets arrange your sequences into shows and to schedule and play your shows To allow your PC to communicate with this controller you will need one of Light O Rama s RS485 adapters When you purchase the Generic Starter Package you get the LOR Showtime Software a 10 Cat e network cable and you will be given a choice of a serial port RS485 adapter or two types of USB RS485 adapters Choose the adapter appropriate for your PC laptop The RS485 adapter CTB16PC will allow you to connect your PC laptop via the Cat e cable to your lighting controller This cont
4. Light Q Rama CTBI6PC 16 Channel Lighting Controller User Manual February 15 2007 V1 02 Copyright O Light O Rama Inc 2007 Table of Contents NTOQUCHOM RESP RR ERR RR O 4 WAALS INN BOX siso a 6 Getting Started with the CTBIOPC 7 Installing CTB16PC in the Plastic Box 8 Preparing Strain Relief Bracket 9 General Power Cable Information 11 How to Connect Unit AC Power Cable s 12 Single Power Feed 15 amp board max 12 Dual Power Feed 30 amps board max 13 Installing Power Cables ccccccceceeeeeeeeeeees 15 Preparing the Rubber Grommets 15 Connecting the Power Cord s 16 Voltage Selection and Operation Jumpers 21 Connecting Controller to PC Data Cable 22 ASSIGNING a UND ESS sn es cs 23 Testing the CTB16PC 25 Designing and Playing a Sequence 26 TROUDISSMOOUING ss nes ne rer 21 SCS BED ee a dans 21 AutoConfigure fails to find COM port 27 Hardware Utility Refresh Fails 28 Updating Controller Firmware 29 Future Capabilities 30 SP CITICALONS ioien ea aa anani 31 CTB16PC Introduction PlanetChristmas and Light O Rama are proud to bring you the CTB16PC
5. ard You can tighten the nuts snug by hand and then tap them tight with a screw driver blade and small hammer or you can tighten them snug by hand with the clamp about 30 counter clockwise and then use a pliers to turn the clamp clockwise until the screw holes face upward The bracket should look like this the large nuts are mostly hidden by the vertical support CTB16PC Remove the three large rubber grommets from the bottom of the plastic box The following picture shows the positioning of the three 3 8 self tapping screws included that will hold the bracket to the plastic box CTB16PC General Power Cable Information Usual wire coloring Hot wires are Black or Brown Neutral wires are White or Blue Ground wires are green On a standard outlet Round hole is ground Short slot is hot Long slot is neutral If you are making your own power connection cables be sure the crimp on quick connects are firmly crimped A loose connection will have resistance which will result in heat which may result in fire Use insulated crimp on connectors to prevent shorts When using zip cord two wire cord the wire with the smooth insulation is used as the hot Frayed wires can cause short circuits that can pose an electrocution hazard may damage this controller and pose a fire hazard Carefully inspect all connections before applying power Be sure no stray strands of wire are sticking out of the crimp on connector Make sure
6. ay be dangerous You should not be able to easily pull off a properly seated quick connect Push all white wires on the neutral terminals grouped together at the center bottom of the board Keep channels 1 8 on the left most set of neutral terminals and channels 9 16 on the right most set This last step is important for a dual AC power feed especially if you are using ground fault interrupters 12 Using the previously labeled black wire quick connects push them on to the appropriate terminals along the left and right sides of the board Your controller should look as shown on the next page 19 lp CTB16PC RE emi F HA 7 45412 3 ms 13 This completes the assembly of your controller Note that this picture shows the fuse covers these were a late addition designed to protect the wires passing over the fuses You are ready to configure it for testing 20 CTB16PC Voltage Selection and Operation Jumpers For 120 VAC operation both jumpers should be installed on the header that is to the lower right of the transformer See following picture 2X116V 50 60Hz TAWA 2X10 0V 2x2 5VA pL 3 og 6 a Eat C3 1000UF A cart Li df Le j VOLTAGE SELECTION a e se 120VAC E iS Le SP a 24QUAC ns For 240 VAC operation only one jumper on the center two pins of this header must be installed There must be a jumper on header JO This is the
7. d be active Plug some lights into your controller and use the sliders and buttons in this section to test your controller 25 CTB16PC Designing and Playing a Sequence Lighting commands for your shows are called Sequences and are designed and implemented using the Sequence Editor Windows software Stop the Hardware Utility You will not be able to command your controller from the Sequence Editor if the Hardware Utility is running Only one program may use the RS485 adapter at a time to talk to lighting controllers There are Quick Start Guides for creating animation non musical and musical sequences Flash Tutorials and much more at www lightorama com gt Support The following Wiki is also an excellent source of information on all things Light O Rama www lorwiki com There is also a very active and helpful Light O Rama user community on Planet Christmas www planetchristmas com 26 CTB16PC Troubleshooting Status LED LED blinking approximately twice second Controller has booted correctly and is waiting for commands The controller is not connected to a Light O Rama network or the network is not active LED is on solid Controller is connected to an active network is receiving the heartbeat and commands from a PC or a DC MP3 Show Director LED is blinking twice then pause twice The normal operation jumper is not on JO the controller is resetting See the section Voltage Selection and Operation
8. e the Refresh button to find your controller and check its firmware version The drop down menu to the right of the Refresh button will be filled in with the attached controllers The right part of the controller name in this drop down is the current firmware version If the controller type or firmware version is not present get the latest Hardware Utility from www lightorama com gt Support gt bottom of page Download Hardware Utility Run program downloaded to install the Hardware Utility and devices text file Retry the Refresh operation The latest firmware can be found by going to www lightorama com gt Support and scrolling down to the Using the Hardware Documentation and Firmware section Find your controller and roll the mouse over the Firmware button look at the bar in the lower left of the browser window It will show the name of the firmware file The file name contains the version at the end If the version number is greater than what you saw in the Hardware Utility new firmware is available Click the Firmware button to download the firmware to your PC remember where you put it 29 CTB16PC To load new firmware use a data cable not wireless to connect the controller s to the PC Start the Hardware Utility and click the Refresh button to find your controller s Select the one you want to update from the drop down menu to the right of the Refresh button Click the Firmware button at the bottom of the
9. larger 18 pin header in the upper right of the board The jumper must be installed on the second row of pins from the top This is the normal operation jumper if not present the board will reset when powered and will not be usable until the jumper is installed and the power cycled See following picture CTB16PC Connecting Controller to PC Data Cable If you have not installed your RS485 adapter do it now If you have an SC485 PC serial port adapter shown on the left below you need only plug it into an available PC 9 pin serial port The cable from a serial adapter to the first controller is limited to 100 or less If you have one of the USB adapters shown center and right above follow the installation instructions that came with the adapter If you are using telephone cable to connect your controller to the RS485 adapter plug one end of the phone cable into the adapter and the other end of the cable into the PHONE CABLE IN jack as indicated in the picture below 21 22 CTB16PC If you are using Cat e LAN cable to connect your controller to the RS485 adapter plug one end of the data cable into the adapter and the other end into either of the CAT5E CABLE IN or OUT jacks shown in the previous picture Assigning a Unit ID If you have not installed the Light O Rama Windows Showtime Software do it now The board will need to be powered at this point BE VERY CAREFUL there are dangerous voltages pre
10. ller rubber grommets Arrange the cords in the grommet as three layers three cords in the top layer three cords in the middle layer and two cords in the bottom layer the layer near the curved end of the grommet Then push the quick connect ends through the large left cable 16 CTB16PC CTB16PC clamp About 872 of cable should extend through 8 Separate the black white and green striped the cable clamp Put the top half of the clamp wires and route them as shown in the following back on and tighten the cable clamp s screws picture See page 15 5 Repeat the above process for the right pigtails channels 9 16 6 Place the strain relief grounding bracket into the plastic box sliding the rubber grommets into place Use three 3 8 screws to secure it to the box as shown on page 10 It should look like this 9 Slide all green striped ground wires over the a grounding stud nearest the 8 channel group of wires Make sure you have all grounds on the stud a missed wire could cause a short later Put a lock washer and a bolt on the grounding studs 10 When pushing on quick connects make sure the 7 Connect the AC power cord s as shown in the blade on the circuit board goes into the quick section How to Connect Unit AC Cord s 17 18 1 CTB16PC connect female end Sometimes the blade will go between the plastic and the female metal end this will not provide a good connection and m
11. m Port section The Hardware Utility will search for the COM port that your RS485 adapter is plugged into and select it When assigning a unit ID only one controller may be plugged into the RS485 adapter on the PC Be sure you do not have more than one controller connected Steps to set change unit ID 1 In the Change Existing ID section use the Old Unit ID drop down menu to select Any Unit then click OK in the warning box for changing all unit IDs there should only be one unit attached 2 Use the New Unit ID drop down menu to select 01 If you have more than one controller assign successive unit IDs to them 24 CTB16PC 3 Click the Change Unit ID button to set your CTB16PC unit ID You will see a Unit ID Changed box click OK Your CTB16PC is ready for testing Testing the CTB16PC In the Max Units section of the Hardware Utility window click the Change button Move the slider in the Change Maximum Units box so that the Max Units is set to 10 This will limit the search for controllers to the first 10 unit IDs otherwise 240 controllers would be searched for taking a long time Click the Save button In the Select Unit to Configure Download Test section of the Hardware Utility screen click the Refresh button to locate your attached CTB16PC controller Your controller will appear in the drop down menu to the right of the Refresh Button The Test Unit s Operation section of the screen shoul
12. o prepare your CTB16PC for use 1 Install CTB16PC in the plastic box 2 Prepare strain relief grounding bracket and rubber grommets 3 Connect AC unit power cord s Connect AC power pigtails receptacles 5 Check voltage selection and normal operation jumpers 6 Connect the network data cable Assign a unit ID 8 Test the CTB16PC A y CTB16PC Installing CTB16PC in the Plastic Box If you purchased the plastic box for the CTB16PC then you should have also purchased the CTB16PC with regular heat sinks already installed The screw holes in the box are designed for the regular heats sinks The heat sinks are held slightly away from the box by the screws on the back of the heat sinks Hold the controller firmly against the back of the box Use four of the 3 8 self tapping screws that came with the plastic box to attach the controller by its heat sinks to the plastic box Tighten the screws just enough to be snug gt ghi Rama E sg E a ET i E F PE mE oe CTB16PC Preparing Strain Relief Bracket lf you purchased the optional plastic box for your controller prepare the strain relief grounding bracket by removing the bolts and lock washers from the two grounding studs Also remove the four screws and clamps from the two large cable clamps Tighten the cable clamps to the bracket using the large nuts on the inside of the clamp Make sure the screw holes face upw
13. roller is designed to control incandescent or line voltage LED light strings It operates on 120 240 VAC 50 60 Hz It can handle up to 30 amps when the factory mounted heat sinks are ordered The 30 amp configuration can control approximately 9 000 mini lights As with all LOR controllers this controller is field firmware upgradeable so you are guaranteed compatibility with future LOR hardware and software products CTB16PC What s in the Box This depends upon which options you ordered At a minimum you will receive the controller and this user manual The latest version of this manual is also available at www lightorama com gt Support gt CTB16PC User Manual The following options are available for this controller e No heat sinks e Regular heat sinks these are factory installed e One 6 AC power cord and power jumpers e Two 6 AC power cords e Sixteen 18 AC output receptacles e Outdoor plastic box with internal component mounting screws and cable strain relief grounding bracket Caution This product requires that you have an understanding of electrical wiring It requires connections to 120 240 volt AC power The board has many exposed line voltage connections that are dangerous The board should be mounted in a safe enclosed box when it is powered CTB16PC Getting Started with the CTB16PC Depending upon the options you selected when ordering your CTB16PC you will have to do some of the following t
14. sent on the exposed circuit board Take appropriate precautions with children and pets Plug the CTB16PC power cord s into AC power The LED near the RJ45 jacks will blink about twice second This means that the board has booted and is waiting for the PC to talk to it Start the Hardware Utility click start All Programs LightORama Light O Rama Control Panel There will be a light bulb with a blue halo on the right side of the task bar at the bottom of the screen Right click the light bulb and select Hardware Utility from the menu Make sure the LOR Control tab is selected You will see the window shown on the next page 23 CTB16PC Light O Rama Hardware 1 6 1 LOR Control LOR MP3 LOR RF Digital IO Boards X10 CM114 Setup Comm Port Select Unit to Configure Download Test Max Units Auto Configure Refresh Select Unit 5 Change Manual Select Comm 7 7 Test Unit s Operation Select Circuits to Test IR ee RR RR REM RE E Set Unit IDs gs m ws RI For Units without Selectors Ignore Errors Set New Unit ID Select Number Select Effect Chase Sequence SetUntiD Of C On Fast Shimmer C Twinkle C Fade on Select Number Y Fade off r Fade New Unit ID Resend Cmd Rate Select Number Change Ur ID Test Configure Standalone Firmware Eor Lights Off Settings Intensity Change Existing ID Old Unit ID Click the Auto Configure button in the Setup Com
15. window In the Firmware section of the window under Step 1 Select Unit select the unit listed above Under Step 2 Select Firmware File use the Open button to browse to the firmware file you downloaded Under Step 3 Press Download Button click the Download button Do not interrupt this process Your controller will reboot after the download completes You can click the Refresh button to see that the new firmware was loaded into your controller Repeat this process for additional controllers Future Capabilities The eighteen pin header on the board provides for digital inputs digital outputs and servo outputs These will be activated at a later date The digital inputs are designed to work with the interactive show feature of the LOR II Showtime Windows Software 30 CTB16PC Specifications Individual Channel 1 amp No Heat Sinks Individual Bank 8 amps No Heat Sinks Board Capacity 15 amps No Heat Sinks Board Capacity 16 amps No Heat Sinks Supply Voltage 120 240 VAC 50 60 Hz 15 amp fast acting Optos isolate line voltage from control logic Quick connects spade lugs 9 wx 11 Z h x 3 Hd Light O Rama Inc Tel 518 539 9000 Fax 518 538 0067 info lightorama com 31
16. you push the quick connect completely on to the board s spade lug Again a loose connection will result in resistance which causes heat and may cause a fire 11 CTB16PC How to Connect Unit AC Power Cable s Single Power Feed 15 amp board max The next diagram shows how to connect the single AC power cord to your CTB16PC If you did not purchase the power cord from Light O Rama you will need to construct one 4 white and one 8 black 14 gauge wire quick connect jumper Both jumpers have female quick connects on each end Remember to attach the ground lug to the strain relief bracket s grounding stud Single Power Feed Connection Diagram Note that in this arrangement both fuses are in use but the right fuse carries the current for both the left and right banks of channels The picture on the next page is just to illustrate the connections for a single power feed do not connect the wires or mount the bracket yet CTB16PC Dual Power Feed 30 amps board max The next diagram shows how to connect the dual AC power cords to your CTB16PC Remember to attach the ground lugs to the strain relief bracket s grounding studs Dual Power Feed Connection Diagram 13 CTB16PC The following picture is just to illustrate the connections for the dual power feed do not connect the wires or mount the bracket yet 14 CTB16PC Installing Power Cables Refer to this picture for instructions that follow

Download Pdf Manuals

image

Related Search

Related Contents

SMC Networks SMCEZNET-16SW User's Manual  cuidado - GE Measurement & Control  Kingston Technology 16GB SDHC Class 4  NV-GS400GN - Pdfstream.manualsonline.com    Controlador Programável MPC1600PLUS  Manual de Usuario e Instalación Estufas TERMOSLIM TIRO  Philips IPLAYER 3 User's Manual  Manuel français  TAFCO WINDOWS NU2-371S-I Instructions / Assembly  

Copyright © All rights reserved.
Failed to retrieve file