Home
        Tektronix: Products > Communications Signal Analyzer CSA8000
         Contents
1.    Communications Signal Analyzer     gt  CSA8000          Digital Communications Analysis Solutions    Specifically designed for high  performance  communications applications  the CSA8000  Communications Signal Analyzer is the ideal  tool for design evaluation and manufacturing  test of datacom and telecom components   transceiver sub assemblies and  transmission systems     The CSA8000 generates measurement  results  not just raw data  with time and  amplitude histograms  mask testing and  Statistical measurements  It provides a  communications tailored measurement  set that includes jitter  noise  duty cycle   overshoot  undershoot  extinction ratio   Q factor  mean optical power and  amplitude measurements     6  Optical Signal Analysis   www tektronix com optical    In addition  mask testing of SDH SONET   Gigabit Ethernet and other standards  simplifies compliance testing     A large  full color display helps you to  discriminate waveform details  Color   grading of waveform data adds a third  dimension   sample density   to your  signal acquisitions and analysis     Modularity and Flexibility   The CSA8000 supports a large and growing  family of optical and electrical plug in  modules  This modular architecture lets   you configure the instrument with the right  features for your application both now and  in the future         gt  Features  amp  Benefits    Automatic Communication  Measurements     Q factor     Extinction Ratio     Optical Power     Signalto noise Rat
2.    Option A99   No power cord    Option AC   China 240 V  50 Hz     Optical Signal Analysis e www tektronix com optical      Communications Signal Analyzer     gt  CSA8000    8000 Series Sampling  Oscilloscope Optical Modules    80C01 Multi rate Telecom Sampling Module with  Optional Clock Recovery   Supports waveform  compliance testing of long wavelength  1 100 to  1 650 nm  signals at 622  2 488 and 9 953 Mb s   as well as general purpose testing w up to 20 GHz  optical bandwidth     80C02 High Performance Telecom Sampling  Module with Optional Clock Recovery     Supports waveform compliance testing of long wave   length  1 100 to 1 650 nm  signals at 9 953 Gb s   as well as general purpose testing w up to 28 GHz  optical bandwidth     80C03 Multi rate  High Sensitivity Datacom  Module with Optional Clock Recovery     Supports waveform compliance testing of short and  long wavelength  700 tol 650 nm  signals at 1 063   1 250  2 488 and 2 500 Mb s  as well as general  purpose testing w up to 2 3 GHz optical bandwidth     80C04 High performance Telecom Sampling  Module with Optional Forward Error Correction  Clock Recovery   Supports waveform compliance  testing of long wavelength  1100   1650 nm   signals at either 9 953 Gb s or 10 664 Gb s as  well as general purpose testing with up to 28 GHz  optical bandwidth     80C05 40 GHz Multi rate Telecom Sampling  Module   Supports waveform testing of long  wavelength  1530   1580 nm  low powered telecom  signals at 9 953 Gb s and
3.  40 Gb s with selectable  bandwidth settings of 20  30 and 40 GHz     80C06 50 GHz Telecom Sampling Module    Supports waveform testing with the highest optical  bandwidth for communications signal analysis avail   able today of long wavelength  1530   1580 nm   high  powered telecom signals at 40 Gb s rates and  50 GHz bandwidth      4  Optical Signal Analysis   www tektronix com optical    8000 Series Sampling  Oscilloscope Electrical Modules    80E01   50 GHz single channel electrical  sampling module     80E02   12 5 GHz dual channel  low noise electrical  sampling module     80E03   20 GHz dual channel electrical  sampling module     80E04   20 GHz dual channel electrical sampling  module with TDR    Other Accessories   Calibration Step Generator      Universal Euro  Order 067 1338 01   UK  Order 067 1338 02    Australian  Order 067  1338 03   North American  Order 067  1338 04   Switzerland  Order 067 1338 05    J apanese  Order 067 1338 06     SIU800 Static Isolation Unit   Order SIU800     Sampling Module Extender Cable  1 meter     Order 012 1568 00     Sampling Module Extender Cable  2 meter     Order 012 1569 00     2X Attenuator  SMA male to female     Order 015 1001 00     5X Attenuator  male to female     Order 015 1002 00     Power Divider   Order 015 1014 00   Rackmount   Order 016 1791 00   P6209   4 GHz active FET probe   P6150   9 GHz passive probe    K4000 Mobile Workstation     Contact Tektronix  ASEAN Countries  65  356 3900  Australia  amp  New Zealand 
4. 0664  p    0 66 Gb s 0654 0  gt  Ordering Information  FEC 42 66 Gb s 42656 0  FC 133 132 81 spina e  FC 266 265 6 Communications Signal Analyzer   Includes  User manual  quick reference card   FC 531 531 2 MS Windows 98 compatible keyboard  MS Windows  FC 1063 1062 5 98 compatible mouse  WaveStar    driver  touchscreen  a stylus  online help  programmer online guide   Gigabit Ethernet 1250 0 power cord         1 0C192 STM 64 Mask is per ITU T  691 recommendation     Power Requirements  Line Voltage Ranges   90 to 132 Vays   180 to 250 Vans     Line Frequency   48 to 440 Hz     Environmental  Temperature     Operating   10  C to  40  C   Nonoperating    22  C to  60  C     Relative Humidity     Operating  Floppy disk and CD ROM not installed   20  to 80  at or below 40  C  upper limit derates  to 45  relative humidity at 40  C     Nonoperating  5  to 90  at or below 60  C  upper  limit de  rates to 20  relative humidity at  60  C      CSA8000 Options   Option C3   Three years of Calibration Service   Option D1   Calibration data report    Option D3   Three years of calibration data reports   Option R3   Extended repair warranty to three years   Option 1K   Cart     Option 1R   Rackmount kit  includes  hardware   tooling and instructions for converting bench model  to rackmount configuration      International Power Plug  Options   Option Al   Universal Euro 220 V  50 Hz   Option A2   UK 240 V  50 Hz    Option A3   Australian 240 V  50 Hz   Option A5   Switzerland 220 V  50 Hz
5. 61  2  9888 0100    Austria  Central Eastern Europe  Greece   Turkey  Malta  amp  Cyprus  43 2236 8092 0    Belgium  32  2  715 89 70   Brazil and South America 55  11  3741 8360  Canada 1  800  661 5625   Denmark  45  44  850 700   Finland  358  9  4783 400   France  amp  North Africa  33 1 69 86 81 81  Germany  49  221  94 77 400   Hong Kong  852  2585 6688   India  91  80 2275577   Italy  39  02  25086 501   J apan  Sony Tektronix Corporation  81  3  3448 3111  Mexico  Central America  amp  Caribbean 52  5  666 6333  The Netherlands  31 23 56 95555   Norway  47 22 07 07 00   People   s Republic of China 86  10  6235 1230  Poland  48  22 251 5340   Republic of Korea 82  2  528 5299   South Africa  27 11  254 8360   Spain  amp  Portugal  34 91 372 6000   Sweden  46 8 477 65 00   Switzerland  41  41  729 36 40   Taiwan 886  2  2722 9622   United Kingdom  amp  Eire  44  0 1344 392000  USA 1  800  426 2200    For other areas  contact  Tektronix  Inc  at 1  503  627 1924    For the most up to date product information  visit our web site at www teKtronix com    CE  amp        Copyright    2001  Tektronix  Inc  All rights reserved  Tektronix products are  covered by U S  and foreign patents  issued and pending  Information in this publi   cation supersedes that in all previously published material  Specification and price  change privileges reserved  TEKTRONIX and TEK are registered trademarks of  Tektronix  Inc  All other trade names referenced are the service marks  trademarks  
6. d to   direct trigger    Clock recovery triggers  from optical sampling modules     internally connected to pre scaled trigger     Trigger Sensitivity    External direct trigger output   50 mV  DC   4 GHz  typical    100 mV  DC  3 GHz  guaranteed    Pre selected trigger input   800 mV  2 to 3 GHz  guaranteed    600 mV  3 to 10 GHz  guaranteed    1000 mV  10 to 12  5 GHz  typical      J itter    Short term jitter optimized mode     1 0 ps  5 ppm  typical     lt 1 5 ps  10 ppm  max    Locked to 10 MHz reference   1 6 ps  0 05 ppm of position  typical     lt 2 5 ps  0 1 ppm of position  max       Internal Clock   Adjustable from 25 to 200 kHz   drives TDR  internal clock output and calibrator      Trigger Level Range    1 0 V   Trigger Input Range    1 5 V              Trigger Holdoff   Adjustable 5 us to 100 ms in  2 ns increments     Display Features  Touchscreen Display   10 4 in  diagonal  color     Colors   16 777 216  24 bits      Video Resolution   640 horizontal by 480 vertical  displayed pixels     Math Measurement   System Measurements   The CSA8000 supports up to eight simultaneous  measurements  updated three times per second  with optional display of per measurement statistics   min  max  mean and standard deviation      Measurement Set     Amplitude Measurements  High  Low  Amplitude  Max   Mid  Min  Peak to peak    Overshoot    Overshoot   Mean  Cycle Mean  RMS  Cycle RMS  AC RMS  Gain   Timing Measurements  Rise  Fall  Period  Frequency     Cross    Cross    Widt
7. h    Width    Duty   Cycle    Duty Cycle  Burst Width  Delay  Phase    Area Measurements  Area  Cycle Area    Eye Pattern Optical Measurements  Extinction Ratio   Ratio     dB   Eye Width  Eye Height  Crossing    Duty  Cycle Distortion  J itter  p p  RMS   Noise  p p  RMS    Q Factor  SNR  Average Optical Power     Cursors   Dot  vertical bar and horizontal bar cursors     Waveform Processing   Up to eight math waveforms can be defined and  displayed using the following math functions  Add   Subtract  Multiply  Divide  Average  Differentiate   Exponentiate  Integrate  Natural Log  Log  Magnitude   Min  Max  Square Root and Filter    In addition  measurement values can be utilized as  scalars in math waveform definitions     Mask Testing   In addition to user defined masks   the following predefined masks are built in     Communications Signal Analyzer        gt  Mask Testing k                       gt  CSA8000    Altitude   Operating  3 048 m  10 000 ft     nonoperating  12 190 m  40 000 ft       Electromagnetic Compatibility   89 336 EEC                                                        Standard Rate  Mb s  Safety   UL3111 1  CSA1010 1  EN61010 1   OC 1 51 84 IEC61010 1   OC 3 5TM 1 155 32 Physical Characteristics  OC 9 466 56  OC 12 STM 4 622 08 Cabinet    Dimensions mm in   0C 18 933 12 Width 457 18 0  0C 24 1244 2 Height 343 13 5  OC 36 1866 2 Te   7  Weight    OC 48 STM 16 2488 3 t hi ie  OC 192 STM 64  9953 3 Shipping 36 7 81  OC 768 STM 256 39813 12  FEC 10 66 G 1
8. io     Jitter    Wide Bandwidth  DC to  50 GHz with up to  12 5 GHz Trigger     Automatic ITU ANSI  Mask Testing    Normal  Infinite  Variable  Persistence and Color  Graded Display Modes    Intuitive User Interface    Large Color Display  10 in      MS Windows   Operating System    Modular Architecture  Fast Acquisition Rate    Excellent Signal Fidelity   J itter  lt l ps RMS   Typical     FrameScan      Acquisition Mode     Isolate Data  Dependent Faults     Examine Low power  PRBS Signals     gt  Applications    Manufacturing Testing for  ITU ANSI Conformance    Designing Verification  of Telecom and  Datacom Elements       Tektronix        ONILNdWO9    SNOILVIINNWWOI    Communications Signal Analyzer     gt  CSA8000    The available optical modules provide com   plete optical test solutions for both telecom   622 Mb s to 40 Gb s  and datacom  Fibre  Channel and Gigabit Ethernet  applications     Each optical module includes all of the ele   ments necessary for communications testing   including an optical to electrical converter  an  average power monitor  one or more reference  receiver filters  a full bandwidth path and a  low noise electrical sampler  In addition    clock recovery is available as an option for all  optical modules     The electrical plug ins include a variety  of modules with bandwidths up to 50 GHz  and specialized features such as TDR   High bandwidth probes are also available  for constructing a total acquisition and  measurement solution     Superi
9. is can be done directly on the  instrument using commercially available  software packages      gt  Characteristics    Signal Ac quisition  Acquisition Modes   Sample  normal   envelope  and average     Number of Sampling Modules Accommodated    Up to four  dual channel electrical and two  single   channel optical sampling modules     Number of Simultaneously Acquired Inputs   Eight  channels maximum  eight electrical or two optical and  six electrical      Vertical Systems  Rise Time Bandwidth   Determined by the sampling  modules used     Vertical Resolution   14 bits over the sampling  modules    dynamic range     Horizontal System  Main and Magnification View Timebases   1 ps div  to 5 ms div in 1 2 5 sequence or 1 ps increments     Time Interval Accuracy     Horizontal sensitivity  lt 21 ps  1 ps   1  of interval   Horizontal sensitivity  gt 21 ps    8 ps   0 1  of interval  short term optimized mode    8 ps   0 01  of interval  locked to 10 MHz mode    Horizontal Deskew Range    500 ps to  100 ns on any  individual channel in 1 ps increments     Record Length   20  50  100  500  1 000  2 000   4 000 samples     Magnification Views   In addition to the main time   base  the CSA8000 supports two magnification views   These magnifications are independently acquired  using separate timebase settings     Maximum Trigger Rate   200 kHz     Trigger System   Trigger Sources     External direct trigger    External pre scaled trigger    Internal clock trigger  Internally connecte
10. or Performance   With its industry  best horizontal stability   trigger jitter  signal sensitivity and noise  performance  the CSA8000 ensures the  most accurate acquired signal for high speed  optical communications testing     The CSA8000 s multi processor architecture   with dedicated per channel Digital Signal  Processors  DSP   also provides industry   best waveform acquisition rates that   shorten test times     The CSA8000 s FrameScan    acquisition  mode can be used with a variety of BERTs  and or protocol analyzers to isolate pattern  dependent effects in transmitters or show the  bit sequence leading up to a mask violation   FrameScan acquisition mode also allows the  averaging of eye diagrams  This can be used  to extract a clean eye diagram from noisy  low level signals      2  Optical Signal Analysis   www tektronix com optical    8000 Series Sampling  Oscilloscope Platform    The CSA8000 is built on Tektronix    new  sampling oscilloscope platform that  combines familiar MS Windows based PC  technologies with world class waveform  acquisition technology     This platform provides a wide array of  standard instrumentation and communications  interfaces  such as GPIB  Parallel Printer Port   RS 232 C and USB Serial Ports and an  Ethernet LAN connection   In addition    the platform includes several mass storage  devices  floppy disk  removable hard drive  and CD ROM      Finally  because the system supports an open  Windows environment  new levels of   data analys
11. or registered trademarks of their respective companies     08 01  HB XBS 85W 13499 3    Tektronix    Enabling Innovation    
    