Home
RTR970B FTR 970B
Contents
1. eee EEA 4 VIISTOSTI S TAI UTIMS 4 Siehe ee ee Temm 4 SETTINGS 9 CONNECCION 2111 ET 9 Maji Getler etn ot atta ani et 9 216 5 50119 6 E E E 10 SPECIFICATIONS 11 INSTALLING WHERE TO INSTALL The RTR model is 35 mm DIN rail mountable and FTR is wall mountable Desktop use is also an option The best place for a receiver is a big grounded horizontal metal level surrounded by as few as possible vertical metal surfaces Antenna is to be installed perpendicular to the metal level with a corner piece or extension cord The best range for the transmitter is achieved when there is a direct view from receiver to the transmitter The walls and objects between the transmitters will dampen the signal and thereby shorten the range On the other hand metal surfaces cause reflections which might lengthen the range CONNECTIONS e SV Di DD RD TWD Re RF ae USB RS 485 RS 232 bus can be used to connect the device via serial communications Each of these connections will be covered in their own chapter below By default the device is jumpered to use the USB bus If RS 485 or RS 232 bus is to be used the serial bus needs to be jumpered differently Open the case by pressing in the f
2. Baud rates 300 600 1200 2400 4800 9600 19200 USB Connector USB type B female Protocol Nokeval SCL Baud rates 300 600 1200 2400 4800 9600 19200 Supply voltage Connector 1 1 33 mm DC jack center positive Connector 2 detachable screw port connector with 3 5 mm raster terminal 1 terminal 2 Connector 4 USB type B female Voltage 8 30 VDC Environment Operating temp Protection class 30 60 C RTR970B IP20 FTR970B IP65 LEDs RS Serial bus indicator RF Radio receiver indicator Power Power indicator behind RS and RF LEDS Settings Connection RS 232 485 or USB Protocol Nokeval SCL Meku 1 Software Mekuwin for Windows 98 XP Dimensions RTR970B 70 x 85 x 60 WHD 60 mm 35 mm 5mm 85 mm 20 mm FTR970B 80 x 130 x 60 WHD Antenna 100 mm 14 mm Regulations EMC directive EMC immunity EMC emissions R amp TTE directive EN 300 220 class 3 EN 300 489 EN 300 339 EN 61326 EN 61326 class B 11 Nokeval made to measure Manufacturer Tel 358 3 3424800 Nokeval Oy Fax 358 3 3422066 Yritt j katu 12 www nokeval com FIN 37100 Sales sales nokeval com Suomi Technical support support nokeval com 12
3. RADIO DATA RECEIVER e measure DESCRIPTION RTR970B and FTR970B have only one difference the case The benefits in upgraded B version Antenna is moved to the middle in both models and an USB bus has been added to the FTR model B version of FTR is also about half the size of the original The device is a radio data receiver for Nokeval MTR series wireless transmitters It receives and buffers the data packets which have been sent by MTR transmitters It automatically recognizes the types of the transmitters so different kinds of transmitters can be used simultaneously Transmitters can also have different transmission intervals The device uses license free 433 92 MHz frequency band ISM so it can be freely used for example almost in whole Europe RTR970 is 35 mm DIN rail mountable but desktop use is also possible FTR970 is wall mountable The receiver is connected to a computer using RS 485 USB or RS 232 bus and it requires PromoLog application that reads the information from the device Nokeval SCL protocol is used for data transmission between the receiver and the computer Multiple receivers can be connected in parallel to an RS 485 bus to increase the covered area The receiver has three indicator LEDs and it requires 8 30 VDC or USB covered area 50 200 m NN CONTENTS PE SCRIPTION 2 CONTENT IN TAGLINC ene
4. easily be added to a computer by using Nokeval DCS770 or DC771B USB RS 485 converter or RCS770 USB RS 232 RS 485 converter RS 485 bus is connected to terminals 3 D1 and 4 DO Two wire ay If the master device in RS 485 bus has the common terminal the two wire jumper must be set to no position If the master device doesn t have the common terminal the jumper must be set to yes position If the device is the last device on the bus it is recommended to set the term jumper to on position When this jumper is set AC termination is used which means that 1 nF capacitor and 110 ohm resistor are connected in series between the bus wires Length of RS 485 bus can be 1km and it can be connected to 32 devices more can be connected via repeating transmitters RS 232 To use RS 485 bus jumper J11 has to be set as the picture below Jumper J7 has nothing to do with using the RS 232 bus The supply voltage 8 30 VDC is connected using 1 3 mm DC jack center connector positive or by using detachable screw post connector terminals 1 and 2 Both supply voltage connectors are internally connected The receiver is protected against wrong polarity of the supply voltage The supply voltage s negative terminal is also used as ground for RS 485 and RS 232 RS 232 bus is not recommended since it is easily disturbed and the maximum length of the cord is only 15 meters in good circumstances Long distances should be co
5. asteners on both sides of the RTR970 case The case of FTR970 is opened by removing the screws ANTENNA CONNECTION Antenna is attached to the BNC connector by connecting the two locking pins after which the ferrule at the foot of the antenna is to be turned 90 degrees clockwise Antenna can be removed by turning the ferrule counterclockwise after which the antenna can be pulled off USB To use USB bus jumper J11 has to be set as the picture below Jumper J7 has nothing to do with using the USB bus The device is jumpered like this as default EH The device gains the supply voltage through the USB but to ensure that the device will operate while the computer is turned off connect the supply voltage 8 30 VDC either by 1 3 mm DC jack center connector positive or by detachable screw post connector terminals 1 and 2 Both supply voltage connectors are internally connected The receiver is protected against wrong polarity of the supply voltage RS 485 To use RS 485 bus jumper J11 has to be set as the picture below B The supply voltage 8 30 VDC is connected using 1 3 mm DC jack center connector positive or by using detachable screw post connector terminals 1 and 2 Both supply voltage connectors are internally connected The receiver is protected against wrong polarity of the supply voltage The supply voltage s negative terminal is also used as ground for RS 485 and RS 232 If necessary RS 485 interface can
6. e E Communications Port COT A E Communications Fark 142 ECP Printer Port LPT1 e 29 Infrared virtual COM port COME Prolific USB to Serial Comm Port COM SETTINGS CONNECTION SETTINGS Use Mekuwin program to configure the device You can download Mekuwin from Nokevals web site for free Default communication settings for configuration e speed 9600 baudia protocol SCL e address O MENUTREE Menu of the device Rev Serial communication settings Note that the changes here do not affect until the device is rebooted SERIAL SUBMENU SER Address SCL address selection Allowed addresses are 0 123 Baud Baud rate selection Options are 300 600 1200 2400 4800 9600 and 19200 RECEIVE SUBMENU Rcv CRCChk If selected CRC checksum of received data packets is checked and corrupted packets are rejected The setting is on by default and there is no reason to disable the setting CH1ID CH4ID Four MTR series transmitters except MTR260 and FT10 can be defined to act as certain channel For example when the device receives MEA CH 1 command it sends latest received data from the transmitter that has been assigned to channel one To assign a device to channel one set the transmitter s ID to CH1ID value Other channels can be assigned in the same way SCL PROTOCOL A more detailed description of the Nokeval SCL protocol can be downloaded from Nokeval www pages Some additi
7. onal commands have been added to SCL protocol for MTR and RTR series devices that are not covered by the general SCL manual These commands are explained in the list below Device supports the following SCL commands TYPE Returns the model name and software version SN Returns the device s serial number for example A123456 MEA CH x Returns the last received value from the device that is defined as channel x DBG 1 Returns the oldest unread data packet from the buffer DBR 1 xx Returns a data packet from the ring buffer location xx DBX Clears the ring buffer DBS 1 Returns the size of the ring buffer 10 SPECIFICATIONS Radio receiver Antenna Connector 50 O BNC female connector Standard antenna helical whip antenna BNC connector Radio Max input power 10dBm Frequency band license free 433 92MHz sub band according to ERC REC 70 03 Bandwidth 180 kHz Selective filter Yes SAW type Sensitivity 100 dBm 3 10 3 error ratio Decoder Buffer memory 96 latest transmissions Serial connections RS 485 Connector Detachable screw post connector with 3 5 mm raster combined with power supply terminal 3 D1 terminal 4 DO Maximum cable length is 1000 m Protocol Nokeval SCL Baud rates 300 600 1200 2400 4800 9600 19200 RS 232 Connector Detachable screw post connector with 3 5 mm raster terminal 6 TxD terminal 7 RxD Maximum cable length is 10 m Protocol Nokeval SCL
8. or the following hardware device O RTR970 Radio Receiver The wizard searches for suitable drivers in its driver database on your computer and in any of the following optional search locations that you specify To start the search click Next If you are searching on a Floppy disk or CD ROM drive insert the floppy disk or CD before clicking Next Optional search locations E Feed disk drives Specify a ee Microsoft Windows Update lt Back Cancel Found New Hardware Wizard Driver Files Search Results P The wizard has finished searching for driver files for your hardware device Sy The wizard found a driver for the following device O RTRS70 Radio Receiver Windows found a driver for this device To install the driver Windows found click Next fe d driverssftdSvep drivers nonpnp ftdibus inf Cancel When USB bus driver ftdibus inf is installed Windows wants to install the virtual serial port driver which makes the device look like an ordinary COM port Found New Hardware m USE Serial Port E 1 Ce m Installing Install in the same way as the bus driver Finally it is necessary to find out which COM port represents the device Open Control Panel System Hardware Device Manager In the device tree expand Ports and there should be USB Serial Port COM3 for example H H adaprers H Other devices 8 24 Ports COM amp LPT
9. vered with RS 485 bus USB DRIVERS The USB interface chip needs two drivers one for USB bus and the other to create a virtual serial port The drivers can be obtained from a Nokeval Software CD or downloaded from the homepage of Nokeval at www nokeval com The installation below assumes using CD but using downloaded drivers is quite similar Insert the Nokeval Software CD and plug in the device Windows should detect it and start installing automatically Found New Hardware RTRSY Radio Regeer Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps vau install a device driver For a hardware device To continue click Next Cancel Found New Hardware Wizard Install Hardware Device Drivers Pha as device driver is a program that enables a hardware device to work with Sy an operating system This wizard will complete the installation Far this device KIRSA Rado Recea device diver is a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the Installation click Mest What da you want the wizard to do CD Display a list of the known drivers for this device so that can choose a specific driver lt Back Cancel Found New Hardware Wizard Locate Driver Files Where do you want Windows to search For driver files Search for driver files f
Download Pdf Manuals
Related Search
Related Contents
Tech air TANZ0326 Continental Electric CE22161 User's Manual Quantibody Human Cytokine Array 1 RayBiotech, Inc. Sony ICF-CD1000 User's Manual Samsung SGH-X650 Kasutusjuhend Tempos e Andamentos nas Políticas de Educação 1.SEEWORLD waterproof gps tracker S116 user manual.rar Copyright © All rights reserved.