English User Manual
Contents
1. Rear Panel PTT INHIBIT POWER ia OUT2 our pom En GC pa l e CN OO l Peay Ee TEST i MAX INPUT LEVEL 26dBm 7 5 TONE 11 d y IN4 IN2 IN3 WI lt a O lt 14 REF REF FWD FWD a SEH A I I u u iLINK SERIAL ANS ma O DC 13 8V 1 3A 1 3 10 0 Fo 15 TEE Y LAN SENSOR SENSOR 1 2 3 1 SENSOR 1 FORWARD FWD or VOLTAGE U SAMPLE INPUT o FWD U connection port of SENSOR 1 o serves as INPUT 1 in 4 INPUT mode SENSOR 1 REFLECTED REF or CURRENT I SAMPLE INPUT o REF I connection port of SENSOR 1 o serves as INPUT 2 in 4 INPUT mode SENSOR 2 FORWARD FWD or VOLTAGE U SAMPLE INPUT o FWD U connection port of SENSOR 2 o serves as INPUT 3 in 4 INPUT mode SENSOR 2 REFLECTED REF or CURRENT I SAMPLE INPUT o REF I connection port of SENSOR 2 o serves as INPUT 4 in 4 INPUT mode PTT INHIBIT IN1 o configurable input coupled to SENSOR 1 PTT INHIBIT OUT1 o configurable output coupled to SENSOR 1 PTT INHIBIT IN2 o configurable input coupled to SENSOR 2 PTT INHIBIT OUT2 o configurable output coupled to SENSOR 2 TEST TONE o internal tone generator output 4 pole 3 5mm jack LAN o IEEE 802 3 Ethernet port AUX o Accessory port LINK o first iLINK port for connection to LINK enabled microHAM devices LINK o second iLINK port for connection to LINK enabled microHAM devices SERIAL o RS232 port for general low speed connectivity DC 13 8V
2. Session OM7ZZ TP address data port 192 168 1 36 1234 ls User ID FA admin Lx Password MAC address 00 1F C0 AC 05 76 Active session om7zz y Y Connect after startup Options E Switch to COMPACT mode after connected M Preserve window layout 7 Stay on top E Log communication 2 Show peak hold for top bargraph values where applicable M Show peak hold for bottom bargraph values where applicable AUTO range switch to lower timeout s D 10 120 g Polling rate 566 78B s of 27 67kB s Switch to COMPACT mode after connected Remote Control starts in COMPACT mode Preserve window layout remembers position of normal window as well as compact window on desktop Stay on top sets application to stay on top of other programs on desktop Log communication logs data exchange for troubleshooting Do not check it until you re asked Show peak hold for top bargraph where applicable shows power peak hold segment on top bargraph Show peak hold for bottom bargraph where applicable shows power peak hold segment on bottom bargraph 4 AUTO range switch to lower timeout Sets down ranging time This setting is equivalent to the BAR DOWNRANGING parameter from the SYSTEM MENU MISCELANEOUS Since Remote Control application has independent settings this parameters is set separately 5 Polling rate Sets polling rate This setting allows to limit dat
3. Sensor 2 must be connected to SENSOR 2 IN ports IN3 IN4 Ifyou are connecting two SMORF boxes to LINK bus of MK2R it is necessary to set radio assignment it defines which SMORF belongs to the RADIO 1 ID 1 and which belongs to the RADIO 2 ID 2 37 microHAM 2015 All rights reserved This METER MODE has been designed for use with two sensors operating at the same frequency In this meter mode SMORF provides unique features gain or attenuation and phase shift measurements between sensors Typical RF setup is when sensors are connected in series measuring parameters of the device inserted in between them as shown on drawing below usually Power Amplifier but sensors not necessary need to be in series it is important to ensure that they operate at exactly the same frequency They can be connected to two independent ports of any RF box stacking phasing box providing both amplitude and phase measurement between sensors Typical application is advanced measurement on Power Amplifier or other devices under test Keep following instructions METER MODE MODE SINGLE FADI SENSORS IN SERIES RADIO TD 1 Sensor 1 must be connected to SENSOR 1 IN ports IN1 IN2 In series setup this sensor should be placed in front of the tested device towards signal source transceiver Sensor 2 must be connected to SENSOR 2 IN ports IN3 IN4 In series setup this sensor should be placed after the tested device towards lo
4. 2 AMPLITUDE Sets amplitude Y axis scale and offset Turning knob changed Amplitude Offset When pushed and turned it changes Vertical Amplitude Scale Scale is labeled in decibel dB units 3 CURSORS MODE Same as in Oscilloscope screen SMORF provides two cursors CURSOR 1 and CURSOR 2 for measurements on computed spectrum image They work in two modes Tracking and Free mode In Tracking mode indicated by CT icon Y position of the cursor is stuck to the waveform while X position can be adjusted In Free mode indicated by CF icon both X and Y positions of the cursor can be adjusted On screen cursors are indicated by small square labeled 1 or 2 4 CURSORS Cursors can be controlled by placing selection to cursor 1 or 2 field Their position in amplitude and frequency is numerically presented in in table on the right side of display Bottom line of the table with A sign shows difference between CURSOR 1 and CURSOR 2 for both amplitude and frequency Cursors have slightly different control according to their mode In Tracking mode turning the knob on selected cursor changes its horizontal frequency position When pushed and turned the other cursor changes its frequency position It simplifies manipulation with both cursors In Free mode both cursors must be controlled separately Turning the knob on selected cursor changes its horizontal position when pushed and turned it changes its vertical position 5 TONE TONE field is shortcut to
5. 4 T BAR Top Bar Graph data or ANT S1 ANT S2 Selected Antenna Cable e Shows what data are shown on TOP Bar graph e Shows antenna cable selected for current frequency band for SENSOR1 SENSOR2 5 B BAR Bottom Bar Graph data or ANT S1 ANT S2 Selected Antenna Cable e Shows what data are shown on BOTTOM Bar Graph e Shows antenna cable selected for current frequency band for SENSOR1 SENSOR2 11 microHAM 2015 All rights reserved EDIT MODE Built in SCREENS can be very easily customized in real time cloned for the same layout but different parameters copied between sensors etc As was written above to each sensor up to 16 screens can be associated doesn t matter if they are built in customized or cloned You can have the same screen cloned with same settings for main display because you like the template but you need different settings for bar graphs for example because you want slower movement on SSB or for whatever reason To enter EDIT mode push briefly EDIT button 11 To exit EDIT MODE push briefly EDIT button again In EDIT mode main display 8 shows some fields outlined Outlined fields are parameters that can be changed customized Basic and globally applicable golden rule is What is outlined it can be changed Outline around the parameter which fades in and out means that the parameter is selected and can be changed by Rotary Knob To move selection between parameters use and SCREEN buttons Built in
6. ALARMS copies ALARM table 2 DESTINATION Sets destination screen where selected data will be copied If ALL is selected data will be copied to all screens of selected sensor EXCEPT disabled screens NO in SENSOR x SCREENS ORDER menu 3 SENSOR Sets destination sensor where selected data will be copied 4 COPY Select and push EDIT button to confirm copy SYSTEM MENU SCREENS MANAGEMENT COPY COMPLETE SCREEN This menu is similar to the previous menu but allows to copy screens at a higher level Again it allows to select data CURRENT SCREEN destination and sensor for copying but logically serves to copy complete screen including customized screen layout selected units point of measurement power and impedance types in place of another screen for the same or different sensor At the same time this menu can be used to create a new screen from scratch by selecting one of the default template type to replace another screen Essential feature if you inadvertently overwrite some screen and you haven t any other template of the same type available COPY COMPLETE OHE SENSOR SCREEN COPY CURRENT SCREEN IM PLACE OF STANDARD SCREEN CORY 47 microHAM 2015 All rights reserved 11 SENSOR 1 MENU SENSOR 1 MENU s a sub menu of the MAIN MENU and serves for all sensor related settings Actually there are two sub menus SENSOR 1 MENU and SENSOR 2 MENU but since both have same sub menus and settings and only differenc
7. Arrow Do not show Connecting Y Request shared session keep dients already connected to the same server Co cms microHAM 2015 All rights reserved SMORF Remote Control Application is native touch screen friendly application for Windows and OS X provided by microHAM which fully exploits strengths of direct TCP connection to the SMORF providing real time access to the SMORF measurements Application can be downloaded from www microham com After installation and first start it is necessary to click on SETUP button and set connection parameters Set desired Session name enter SMORF s IP address and DATA port User name and Password and MAC address DATA port and MAC address can be found in LAN SETTINGS menu Than move session into Sessions window clicking on lt button Make new session active and click Save button on the bottom to save entered parameters Click Connect and you should get in That s the quick start but Remote Control Setup allows to set more parameters 1 Sessions List Shows all sessions and their parameters Session can be overwritten by moving same sessions name into list by lt button Highlighted session can be deleted by X button 2 Active session Sets active session for connection Active session can be assigned for auto connect when Connect after start up box is checked 3 Options Sessions LOM7ZZ admin 192 168 1 36 1234 JANO admin 192 168 2 1 1234
8. o power input max 16V center positive shell negative POWER SWITCH GROUNDING SCREW microHAM 2015 All rights reserved 4 INSTALLATION Connect sensor to the meter Connect sensor to the transceiver and the a ds E antenna Connect your antenna to the LOAD port of the sensor L Connect meter to the transceiver or ton rx ent am microHAM i nte rface SENSOR TRANSCEIVER 13 8V DC SUPPLY Connect U or FWD sample output of the sensor to the meter s SENSOR 1 U FWD input using supplied SMA SMA cable It isn t important which one of two supplied SMA SMA cables you use but keep the calibration certificate of the cable and mark it to reflect the connection SENSOR SN U Later you can enter calibration table of the cable from the certificate sheet to the meter memory in SENSOR MENU It will slightly improve metering accuracy but you will need to pair calibration table to the cable each is individually calibrated in the factory Connect I or REF sample output of the sensor to the meter s SENSOR 1 I REF input using second SMA SMA cable Again keep the calibration certificate of the cable and mark it to reflect the connection SENSOR SN 1 If you are connecting the second sensor aa use SENSOR 2 ports on meter in the ourz ours aux same manner as for SENSOR 1 above OO Ee 2 IN3 INA REF REF FWD FWD N2 N1 Se 1 u u Connect antenna port of your transceiver or power amplifier to the se
9. 1 MODE e Changes bar graph drawing mode DOT draws just one segment of actual value BAR draws all segments from left up to actual value 2 AVG ATTACK DECAY e Sets averaging time constants used for average values AVG Range 0 2000ms Step 10ms 14 microHAM 2015 All rights reserved 3 PK ATTACK e Sets attack time used for peak values Pk Range 0 200ms Step 1ms 4 PK DECAY Sets decay time used for peak values Pk Range 0 200ms Step 1ms 5 PEAK HOLD e Turns ON OFF peak hold function When enabled peak value is held on its position as one segment Higher peak value resets lower peak value 6 HOLD TIME e Sets how long the peak segment will be lit on its position Occurrence of higher peak value during the hold will restart this time Range 0 20s Step 100ms 7 P H DECAY e Sets decay time for peak hold segment Range 0 20s Step 100ms 8 EDIT POWER COLOR TABLE e Defines four 4 custom power ranges and colors on per band basis Example BAND COLOR POWER COLOR POWER COLOR POWER COLOR 160m GRN 8W YEL 10W GRN 40W RED 0 8 10 40 MAX A 10 EDIT SWR COLOR TABLE e Defines four 4 custom SWR ranges and colors on per band basis Applicable to bottom bar graph only Example BAND COLOR POWER COLOR POWER COLOR POWER COLOR 160m GRN 1 50 YEL 2 00 RED 3 00 RED 1 0 L 2 0 3 0 a 15 m
10. Contrary to most menus in the SMORF this menu can be left only using dedicated EXIT button It is an intentional change to avoid inadvertent exit from the menu without saving entered values Still values must be SAVED separately by SAVE button prior exit otherwise they will be lost 49 microHAM 2015 All rights reserved SENSOR 1 MENU SENSOR CABLES CALIBRATION When supplied cables are not long enough to connect a sensor to the SMORF and it is necessary to use longer cables the question is how to obtain new calibration data to the Sensor Cables Table Solution is in this menu providing a cables calibration process which helps you to calibrate new sensor cables yourself by comparing them to known calibrated reference supplied cables without any other tool than your transceiver and a dummy load SENSOR 1 CABLES CALIBRATIOH M4 CURRENT REFERENCE ana 5 2 FFEQCMHZ 1 825 HE REFERENCET fee NEL CABLE LEE Push MENO to sample CONTROLS 1 CURRENT Sets which cables are used for sampling REFERENCE sets supplied factory calibrated cables matching the Sensor Cables calibration table NEW CABLE sets new custom sensor cables 2 FREQ MHz Sets calibration frequency in MHz 3 SAVE Saves newly taken samples and recalculates Sensor Cables Table 4 EXIT Leaves the menu Please note if you leave menu prior saving new values all taken samples will be lost 1 Prepare new cables Ca
11. PA SCREEN PA screen is a DUAL sensor screen providing phase locked simultaneous measurements for both sensors operating at the same frequency This screen is available in SINGLE RADIO SENSORS IN SERIES meter mode PA screen is primarily designed to monitor input and output of the Power Amplifier providing power reading and reflection measurements on both input and output of the amplifier as well as its gain However this screen is not limited to Power Amplifiers it can be used for any two port RF box and be valuable for checking phasing boxes power splitters or combiners providing amplitude and phase unbalance measurement EA FuD ker TH PE Geena SwIR TH FWD 2 OS GAIN 21 REF 0 1610U 17145 40 dB FWD o GO PHASE D REF 6 098 141 i PA screen provides four 4 user configurable measurements Each measurement is related to the one of two feed points TX or ANT individually for each sensor In addition to configurable reflections reading absolute value of impedance measurement Z is provided In the rectangle box Gain and Phase between Sensor 2 and Sensor 1 respectively are shown Available measurements 1 FORWARD POWER e FWDyxREF Peak envelope forward power minus reflected power delivered power at the TX feed point e FWDanTREF Peak envelope forward power minus reflected power delivered power at the ANT feed point e FWDtx Forward power at the TX Sensor feed point e F
12. TIME and CALLSIGN Callsign can be edited on screen by default it is set to microHAM SCREEN MODE Sets mode of the screen saver 1 blank screen 2 slowly moving parameters 3 flying parameters Selected mode can be checked by navigating focus to TRY icon turning knob to highlight it and pushing EDIT button SLEEP Sets time of inactivity in minutes when SMORF enters into Sleep Mode In the sleep mode SMORF turns completely off internal RF board and as much as possible internal circuits From the sleep mode SMQRF can wake up by pressing any button or knob Sleep Mode is not entered if there is any active LAN connection ongoing WAKEUP on LAN When enabled SMORF can wake up from the Sleep Mode by magic packet received thru the LAN WAKEUP on PTT When enabled SMORF can wake up from the Sleep Mode by sensing activity on PTT IN port 42 microHAM 2015 All rights reserved SYSTEM MENU AUX PORT intentionally left blank 43 microHAM 2015 All rights reserved SYSTEM MENU TIME DATE SMORF has built in Real Time Clock RTC to allow to mark backups with date signature as well as to provide UTC and local time date for screen saver Special feature is that RTC can be synchronized by internet clock reference and keep time in the SMORF updated and very accurate This menu allows to set time and date its format as well as synchronization parameters CONTROLS TIME DATE 14 44 14 1 UTC 2 YES SY
13. This screen is available in TWO INDEPENDENT RADIOS AND SENSORS meter mode and is suitable for setups with two radios when it is normal that both radios transmit at the same time and it is necessary to monitor power of both radios simultaneously A FWO ker TX PE GA SWR TX FWD 2 077Wp O 000W O 161W O 000Wr 1 73 e 2TX screen provides three 3 user configurable measurements Each measurement is related to the one of two feed points TX or ANT and setting applies to both sensors Available measurements 1 FORWARD POWER FWD1x REF Peak envelope forward power minus reflected power delivered power at the TX feed point FWDanT REF Peak envelope forward power minus reflected power delivered power at the ANT feed point FWDrx Forward power at the TX feed point FWDant Forward power at the ANT feed point REFLECTED POWER REF tx Reflected power at the TX Sensor feed point REF ant Reflected power at the ANT Antenna feed point REFLECTION SWRrx Standing Wave Ratio at the TX Sensor feed point SWRant Standing Wave Ratio at the ANT Antenna feed point RLtx Return Loss dB at the TX Sensor feed point RLant Return Loss dB at the ANT Antenna feed point 2TX screen has a special SCREEN MENU item LED BARS determining which sensor data are used for the bar graphs Selected sensor is indicated by highlighted bar graph icon on the display 31 microHAM 2015 All rights reserved
14. transceiver of power amplifier to the load antenna and provides attenuated sample of current 1 and voltage U on load or attenuated sample of forward FWD and reflected REF power MORE supports both types of samples coming from sensors All supported HF sensors are U I type with current and voltage transformers inside They have no characteristic impedance because current transformer is designed to cause minimal series impedance to load and voltage transformer maximal parallel impedance to load Therefore reference impedance is taken from the characteristic impedance of the connected antenna feed line All VHF UHF sensors are FWD REF type They are designed as directional couplers having main line made as a stripline sensing line as a microstrip and have a certain characteristic impedance 50Q optionally 75Q All sensors have internal micro controller and EEPROM memory for calibration data storage and temperature measurements Each sensor is individually calibrated at multiple frequencies for each band multiple power levels for each frequency and for different operating temperatures at a plane of LOAD connector to the plane of SMA sample connectors These data are stored in this EEPROM memory When sensor is attached to the SMORF and is powered up for the first time SMORF reads out all calibration data from the sensor s memory and makes a copy of these data in its internal memory in order to avoid long waiting time on every subsequen
15. 12 13 14 15 16 17 FIRMWARE VERSION MISCELLANEOUS SETTINGS Shows version of the firmware FIRMUARE VERSION Dad SERIAL NR MAIN SERIAL HA HAIH 17 Shows serial number of the Main Board SERIAL HR RF 17 SERIAL NR RF de Sh ial b f the RF Board ows serial number of the oar METRIC CALIBRATION 1206 RAR dd SMORF calibration HELP LANGUAGE ENGLISH f STARTUP SPLASH 5 Sets level of audible feedback to button SCREEN HOME DS e presses 0 disables button s sound BAR RANGE STATUS 5 UNITS BAR RANGE MEMORY Sets units provided by SMORF for BARS DOLHAHRANGIHG temperature and length It can be set to TUNE SENSITIVITY METRIC or IMPERIAL system TUNE TRIG TIRE SERIAL PORT TUNE HOLDOFF Sets RS232 Serial Port speed Range 1200 115200Bd HELP LANGUAGE Sets language of built in HELP system STARTUP SPLASH Sets how long startup screen will be held on the display STRICT METER MODE Limits METER MODE When set to NO SCREENs AUTO mode and DUAL mode are not limited to METER MODE NO is not recommended setting however if you have two sensors and often changing RF setup due to various experiments it doesn t force you to change METER MODE on every sensor s change SCREEN NAME Sets how long the SCREEN name will be shown on display when SCREEN is changed BAR RANGE STATUS Sets how long the BAR GRAPH range notification will be shown on display when RANGE is changed BAR RANGE MEMORY Sets if current BAR
16. 6 TRANSMISSION LINE LOSS e Shows total loss in transmission line from the TX feed point to the ANT feed point Value can be presented in Watts W dBm or dBW units Screen has no special settings in SCREEN MENU and by default is not shown between SCREENs rotation Visibility can be turned on in SYSTEM MENU SCREENS MANAGEMENT SENSOR x SCREENS ORDER 24 microHAM 2015 All rights reserved OSCILLOSCOPE SCREEN Oscilloscope screen is another great feature of the SMORF Serves for waveform inspection overshoots visualization lead and tail time measurements etc etc It mimics standard digital bench oscilloscope but since SMORF is an instruments for RF power measurements it is optimized for this job and adds some features you will not find on any standard digital oscilloscope We have put a lot of attention to the oscilloscope screen because oscilloscope is the most important instrument in any electronic lab Due to high speed requirements vertical resolution and limited accuracy RF measurements on bench oscilloscope is tricky and inaccurate or demands very expensive model And it is a task where SMORF s oscilloscope screen brings several advantages It has no hardware defined ranges and uses full dynamic range of the meter That means it cannot be overloaded and cursors show exact value of amplitude even if they are not visible or hugely offset Additionally it provides vertical ranges in Watts and dBm not only in Volts Both vert
17. Point and data at this point are shown with ANT suffix after the data type like FWDanr for the forward power or SWRanr for Standing Wave Ratio Although these data are calculated rather than measured SMORF includes precise models of over 30 commonly used coaxial cables to choose from Accuracy of provided results is directly related to the manufacturing differences of the cable to its specification accuracy of the user entered cable length and accuracy of the TX feed point measurements Good cable matches specifications within 5 according to cable manufacturer claims how accurately you measure and enter physical cable length is up to you The SENSOR MENU ANTENNA CABLES chapter deals with antenna cables in more detail Please note by default SMORF uses lossless 500 cable model for all ANT Feed Points to avoid any confusion while you SY aren t familiar with this feature It EEE ten ade doesn t matter if you choose TX or dl EE ANT Feed Point until you edit ANT Feed Point ANTENNA CABLES table Till than result will be the same providing values of TX Feed point in both cases Ce TRANSCEIVER ANTENNA CABLE 12 microHAM 2015 All rights reserved Another suffix used in provided measurements is superscripted REF as in FWD x EF REF abbreviation appears only after forward power FWD and stands for delivered power power which was transferred to the cable or to the antenna cleared of reflected power FW
18. bal a ville el ele A A oa OOo CH GEN CH GN OH GEN OH GA OH E OH GA CH 1 MINIMAL POWER for 1 POWER RANGE Sets minimal power for the 1 power range from where alarms will be generated for all three importance levels MIN WARNING ALARM FAULT MIN settings sets power to gn power threshold value im gt 1 2 MINIMAL POWER for 2 POWER RANGE Sets minimal power for second range from where alarms will be generated for all three importance levels WARNING ALARM FAULT 3 W SWR Sets tripping SWR value for the WARNING level Alarm level can be disabled when set to 4 A SWR Sets the SWR value for the ALARM level Value has to be higher than the value set for the WARNING level H 5 F SWR F cml gt 40 TI Sets the SWR value for the FAULT alarm level Value has to be higher than the value set for the ALARM level L ANAL ALAN ALAN AL ANAL ALAN AN AL ANAL ALAN ANAL ANAL AL AL AR ALERT ylco 4 00 400 u oo u col uloo 4 00 ule0 ulo0 u col uloo y c ulo aus nen en elen e nolaa en eegen nio CC Fa o o o o rn Fazit A 59 microHAM 2015 All rights reserved ALARM 1 MENU LOW POWER ALARM LOW POWER ALARM is a second common alarm type Same as SWR alarm also LOW POWER ALARM has extensive settings allows to set three different POWER values to trip three alarm levels WARNING ALARM FAULT for each band separately as well as provides two power ranges where different power levels c
19. built in tone generator START STOP function When icon is lit tone generator generates defined output Its output is defined in MAIN MENU TONE GENERATOR and settings are unique for the Spectrum screen Spectrum screen has a special SCREEN MENU item DISPLAY TYPE which defines how peak hold values are represented on display Peak value is kept individually for each frequency considering time of its appearance e LINE selection draws peak value as line e AREA selection draws peak value as faded area Please note SPECTRUM screen uses RF envelope data obtained from the peak detector similar to diode detection Therefore do not expect to see the spectrum image of SSB signals as you know them from your digital modes program SDR or panadapter Phase information of the peak detected SSB signal is lost and cannot be accurately reconstructed for unknown modulation signal However it still shows proper spectrum image of AM signals as well as occupied bandwidth in CW mode 28 microHAM 2015 All rights reserved intentionally left blank 29 microHAM 2015 All rights reserved AUTO MODE AUTO mode is a special operating mode of the SMORF which can be applied for any single sensor screen In AUTO mode meter makes automatic sensor focus to the first sensor from which detects power Unfocused sensor is ignored and alarms for this sensor are not generated When power samples from the focused sensor disappear meter restarts automatic se
20. dBW For example OdBm 1mW 50dBm 100W 53dBm 200W 60dBm 1kW OdBW 1W 20dBW 100W 23dBW 200W 30dBW 1kW TYPE After the UNIT field TYPE is displayed as subscript SMQRF supports four power types e PK Peak Envelope Power e AVG Average Power Averaging time is defined in the SCREEN MENU TPK Total Peak Power Maximal peak power achieved within one transmission cycle e TAV Total Average Power Average power of one transmission cycle Available measurements 1 FORWARD POWER e FWD REF Peak envelope forward power minus reflected power delivered power at the TX feed point e FWDant REF Peak envelope forward power minus reflected power delivered power at the ANT feed point e FWDrx Forward power at the TX Sensor feed point e FWDant Forward power at the ANT Antenna feed point 19 microHAM 2015 All rights reserved 2 REFLECTED POWER REFtx Reflected power at the TX Sensor feed point REF ant Reflected power at the ANT Antenna feed point 3 REFLECTION SWRrx Standing Wave Ratio at the TX Sensor feed point SWRant Standing Wave Ratio at the ANT Antenna feed point RLrx Return Loss dB at the TX Sensor feed point RLANT Return Loss dB at the ANT Antenna feed point 4 IMPEDANCE IMPrx Rectangular coordinates R jX complex impedance at the TX Sensor feed point IMPrx Polar coordinates Z complex impedance at the TX Sensor feed point IM
21. enabled 2 STATUS Shows status of the current connection Normally you should see just DISABLED and RUNNING state but there are more states describing status which may help for network troubleshooting HTTP PORT z CLOSED DATA PORT CLOSED UNC PORT Dong 192 168 1 26 MAC ADDRESS 6 64 A3 90 AF 20 DISABLED LAN connection is turned off DOWN internal PHY is turned off CONNECTING waiting for cable connection WAIT SWITCH waiting for response from the LAN switch DHCP SEEK waiting for response from the DHCP server RUNNING LAN connection is running 3 DHCP Lets assignment of the connection parameters to the DHCP server of your internet connection usually your local Router or ISP 4 MANUAL Allows to set the IP ADDRESS NET MASK GATEWAY and DNS ADDRESS manually When you consequently re enable LAN parameters are copied to appropriate positions at DHCP fields 5 LOCAL NAME Sets name of the SMORF for local network 6 RESET PASSWORD Allows to reset password for HTTP and DATA port Default access is login admin password admin 7 HTTP PORT Sets HTTP port default port number is 80 Next to port number real time status is shown CLOSED when there is no connection SERVING when browser is connected and user is logged in HTTP port is protected by password Please note if you have changed HTTP port you have to leave the menu and restart SMORF turn it off and back on New port address is applied
22. high voltage circuits gt 24VDC gt 100mA It is perfectly suitable for all above functions but keep it in mind if you are going to experiment with your own designs Damage caused by improper use is not covered by warranty 58 microHAM 2015 All rights reserved ALARM 1 MENU SWR ALARM First type of the alarm is the most common SWR ALARM But name of the alarm is probably the only thing what SMAQRF has in common with other units SMORF allows to set three different SWR values to trip three importance levels WARNING ALARM FAULT for each band separately In addition SMORF provides two power ranges where SWR can be handled separately it allows to set different SWR tripping values for an amplifier and different for bare transceiver It is possible to set minimal power level from where SWR value can trip alarm and ignore lower levels It is also possible to turn some alarm levels off Lets take 160m band and screen shot as an example First power range is set to 10W 180W second power range for 180W and more lt means if output power will be under 10W no SWR alarm will be generated For the first power range the WARNING level is turned off It means that if output power will be in between 10 180W WARNING level will not be generated but if SWR will be larger than 2 5 or larger than 3 5 ALARM or FAULT level alarms will trip respectively For ALARM level a pop up window will be shown and audible alert will be played DISPL
23. is capable to do all above tasks in real time and at the same time provide DDS based tone generator output for some kind of specific measurements microHAM 2015 All rights reserved nBON 10 11 12 13 14 15 Front Panel SMOQRF op 20 30 microHAM 8 S 12 35 40 6 14 fo TA D o AP A yoy K Po Ch 8 000690003 so D n Se mm 2 0 000000 looong Da Ee 3 Zon w nnt A e STE 007 en 9 40 wan ES 16 a D I A AN AG kee x 42 A ae 00710 2 NS Ri r 6 5 x01 x1 x10 x100 gt 09 RANGE ee e A E D ES ST S ALARM 1 14 11 E 7 A ALARM 2 e MENU SENSOR 1 SENSOR 1 SENSOR 2 150 y SENSOR 2 12 13 AUTO RF VECTOR SIGNAL METER 1 8 500MHz TOP BAR GRAPH BOTTOM BAR GRAPH TOP BAR GRAPH SCALE INDICATOR BOTTOM BAR GRAPH SCALE INDICATOR BAR GRAPH SCALE RANGE INDICATOR o o o green color indicates top bar graph range red color indicates bottom bar graph range yellow color indicates same range for both bar graphs ALARM INDICATORS o o o green color indicates warning red color indicates alarm flashing red color indicates fault SENSOR INDICATORS MAIN DISPLAY LEFT SCREEN ROTATION BUTTON o button serves as left navigation button in EDIT mode and MENU system RIGHT SCREEN ROTATION BUTTON o button serves as right navigation button in EDIT mode and MENU system EDIT MENU BUTTON o o short press ente
24. levels in the table REFERENCE row 7 Unkey radio and return to the point 5 until after you sampled all bands 8 Replace reference sensor cables for new cables Keep reference cables together with matching certificates on a safe place You will need them whenever you will want to recalibrate or replace your custom cables 50 microHAM 2015 All rights reserved 9 On screen set CURRENT cables to NEW CABLE 1 10 On screen set frequency 2 again to the first calibration frequency and switch the radio to this band Verify that the frequency on the screen and the radio match 11 Key the radio let output power to stabilize for a second and push the MENU button to take a sample You should see captured levels in the NEW CABLE row 12 Unkey the radio and return to the point 10 until after you sampled all bands 13 SAVE calibration 3 14 Leave the menu 4 Now you have calibrated your new cables without loosing any single bit of accuracy Newly calibrated values have been automatically copied to the Sensor Cables Table and you can review them by entering that menu Maybe you could write them down and create your custom calibration certificate in case you will want to use new cables with another SMORF without recalibration or data transfer In some situations you don t need to calibrate new sensor cables for all frequencies especially if sensor is located behind some single band power amplifier or radio common situation on VHF
25. or UHF bands In this case whenever it is possible calibrate cables also on adjacent bands As was mentioned SMORF calculates attenuation for other than calibration frequency by interpolating with values for adjacent calibration frequency If adjacent calibration points don t exist SMORF will use the same values for all frequencies within a band If calibration on adjacent bands is for whatever reason not possible it is very important to use very exactly cut as thick as possible cables having as short as possible jumpers to avoid variation in attenuation and phase from start to the end of the band SENSOR 1 MENU POWER LEVELS 100 100 POWER LEVELS is another unique feature of the SMORF As was mentioned in the BAR GRAPHS SCALES and RANGES chapter when TOP LED BAR is set to display power range has one special position 100 It is useful feature for a quick check if the output power is at desired level because 100 power level is always full deflection of the TOP LED BAR GRAPH meats Soe EE is SENSOR 1 190 POWER nother use o power level values is the TUNE SCREEN where you get visual and audio al POWER Cu check when 100 power is reached during tuning 1560 procedure 1506 15848 In this menu 100 power levels can be precisely 1568 daoi set for each band separately according to your 1568 requirements ifm 1566 1500 1566 1568 1 dinaa 156 L pp Lg ricm L pp 51 microHAM 2015
26. samples from A D convertor incoming at fixed rate of 125 thousands samples per second For easier to use decade ranges low ranges or advanced acquisitions scope uses real time decimation and interpolation operations Therefore minimal and maximal horizontal timebase ranges are the same for all acquisition types 2 TRIGGER EDGE defines triggering condition FWD RISING rising edge of the Forward power FWD FALLING falling edge of the Forward power IN RISING logical rising edge PTT activated of the PTT IN input IN FALLING logical falling edge PTT deactivated of the PTT IN input Both IN rising and falling edges includes 0 5ms software debouncing as IN input is usually driven by mechanical contact Processing latency adds additional 0 2ms 27 microHAM 2015 All rights reserved SPECTRUM SCREEN Spectrum screen is similar screen to the Oscilloscope screen but visualizes data in the frequency domain instead of oscilloscope s time domain It uses SMORF s peak detector data and with help of Digital Signal Processing DSP translates them into frequency domain using Fast Fourier Transformation FFT F CONTROLS 1 FREQUENCY Sets frequency X axis scale and offset Turning knob changes Horizontal Scale maximal and minimal frequency Horizontal scale is in Hertz Hz There are three linear horizontal scales and three logarithmic horizontal scales available There is no equivalent of horizontal offset setting
27. second cable result is absolute phase shift between these cables These parameters need to be entered to the table from the calibration certificate SMORF then interpolates between these points to get exact value of the attenuation and the phase for current operating frequency in real time By default the Sensor Cables Table is pre set using typical values of the attenuations of provided cables and zero phase shift so results obtained from an out of the box meter are not way off Anyway to get best out of the SMORF accuracy you need to edit table using actual values from the certificate Phase difference is absolute phase shift between cables and must be worked out using relative phase from two certificates It is the relative phase shift of the cable connecting or REF port of the sensor MINUS relative phase of cable connecting U or FWD port of the sensor Formula for entering phase difference is AO Q l or REF U or FWD SENSOR 1 CABLES TABLE MENU CONTROLS FREGLHHz FWD UREF TI aj 1 FWD U 1 225 Attenuation of the cable connecting 53 615 U or FWD port of the Sensor ba Ze E EG PREE l Attenuation of the cable connecting Ta LEE HR Sr EE 20 REF port of the Sensor 18 120 6 66 o op 21 225 EAS Computed phase difference between 24 944 D Ba both cables formula above 28 856 4 SAVE 51 066 Saving entered values CH 254 98 AG HB 5 EXIT Exit from this menu 145 BE 223 500 435 DEG FREGLHHz 1 EMU REF T
28. will be either repaired or replaced at our discretion The only cost will be the cost of return shipping Cables are warranted against defects in materials and workmanship for a period of 60 days microHAM SMQRF Remote Control the software is provided as is without guarantee of compatibility with any specific operating system computer hardware or accessory microHAM assumes no liability or responsibility for damage to other devices or injuries to persons as a consequence of using our products If the terms of the above warranty are not acceptable return the unit all associated documents and accessories in the original package prepaid to microHAM or to your supplier for refund less shipping and restocking fee 73 microHAM 2015 All rights reserved DECLARATION OF CONFORMITY C Federal Communications Commission Statement USA This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation European Union Declaration of Conformity microHAM s r o declares that the products Product Name RF VECTOR SIGNAL METER Conforms to the following Product Specifications EN 55022 2010 Class B following the provisions of the Electromagnetic Compatibility Directive 89 336 EEC 2004 108 EC 74
29. 7 sensor to the SMORF probably will never happen but if oldest sensor s data in the SMORF memory are replaced by the newest sensor s data These sensor s data are exported to the computer together with content of all three backup slots When you restore config data from the computer back to the SMORF SMORF updates also sensor s data BACKUP RESTORE SETTINGS SLOT Hate rT BACKUP DATE ACTION BACKUP El D 22 06 2015 Ze T 21 66 2615 EE EH 21 86 2815 RESET to FACTORY DEFAULTS MOIS As was described SMORF has allocated memory for three backup slots Each slot is independent can have its own name which is editable in the NAME field 1 and automatically stores date when backup was created not editable Using backups whole SMORF behavior can be switched for three different setups or different QTHs because Antenna s and Sensor s cables specification are included in the backup What to do with the backup is specified by ACTION field 2 which can be set to BACKUP or RESTORE action Action is confirmed by the EDIT button CONTROLS 1 NAME Sets backup slot name 2 ACTION Specifies backup action BACKUP stores all current SMORF s settings to the backup slot Previous content of the backup slot is overwritten RESTORE restores settings stored in the backup slot and overwrites all current settings 3 RESET to FACTORY DEFAULTS Resets all settings to the default factory state Please note all your custom setting
30. AY YES SOUND YES Alarm will be reset by releasing PTT RESET PTT For FAULT level audible alert won t sound SOUND NO but pop up window is forced despite being turned off DISPLAY NO because reset is set to MANUAL In addition SMORF breaks power generated by the radio TX BREAK YES If output power will be higher than 180W SMORF will generate ALARM and FAULT level alarms with the same actions and reset conditions as above but at different SWR values ALARM at SWR gt 2 0 and FAULT at SWR gt 3 0 In addition it also generates lowest WARNING level alarm for SWR gt 1 8 When WARNING is generated pop up window will be shown DISPLAY YES without sound or breaking power SOUND NO TX BREAK NO Warning will be cleared automatically when SWR drops below 1 8 and after a 1s timeout AUTO 1s without requirement to interrupt power RESET AUTO SUR ALARM 1 SS SWR I Of course all SWR power values actions and reset conditions are ALARM DISPLAY ES FES or adjustable Easy to understand example values were chosen to A NO YES w show that settings can fit everything from don t care about SNZE 1 m RESET O PTT MANUAL alarms or one rule for everything above 3 0 is good for me up to I D baeroe RANGE U SUR pap F SUR need precise adjustments and rules for each band separately 1g 180 gt 2 5 gt 3 5 186 gt 1 8 gt 2 6 gt 3 4 gt CONTROLS 2 50 a te Val bal Kai co O oi oO co Val
31. All rights reserved SENSOR 1 MENU ANTENNA CABLES In previous chapters we have several times used and described term two point measurements so you should be already familiar what does mean ANT feed point To calculate power at the ANT feed point SMORF needs to know what kind of cable is used to connect antenna and its physical length This purpose serves ANTENNA CABLES menu which allows to set cable model connecting particular antenna as well as set its length Additionally it allows to set meaningful cable name according to the name of the antenna every cable ends up at some antenna and assign antenna to bands where is used SMAQRF has allocated memory for up to 32 different antenna cables per sensor each cable is identified by its unique ID number There are more than thirty 30 built in precise models of common coaxial cables types to choose from There is one special cable called Lossless 50Q which is used as default It is a virtual cable which just specifies reference impedance for the ANT feed point calculations and since it has no loss entered length is irrelevant Results using this cable will be same as measured values at the TX feed point Use this cable if your cable is not available or you have no idea what cable or length you are using to avoid reading incorrect and misleading results for the ANT feed point ID HARE L Uni CABLE TYPE Andrew CNT GE CONTROLS 1 ID Selects Antenna Cable identification nu
32. B turn one step CW KNOB turn one step CCW Left Shift KNOB press 1 SENSOR 1 button 2 SENSOR 2 button 3 AUTO mode 4 DUAL mode PgUp Value increment by 10 PgDown value decrement by 10 Home Jump to minimal value End Jump to maximal value 67 k pi E New TightVNC Connection f ees Connection Enter a name or an IP address To specify a port number 7 append it after two colons for example mypc 5902 _ Options Remote Host 192 168 2 1 5900 Reverse Connections Listening mode allows people to attach your viewer to their desktops Viewer will wait for incoming connections Listening mode TightVNC Viewer TightVNC is cross platform remote control software E Its source code is available to everyone either freely GNU GPL license or commercially with no GPL restrictions VNC Version info l Configure Seen Display Scale by Format and Encodings Preferred encoding Tight e y 256 colors less traffic Auto Full screen mode Set custom compression level Deiconify on remote Bell event Mouse F Swap right and middle buttons EG set image quality Mouse Cursor Track remote cursor locally Let remote server deal with cursor y Allow CopyRect encoding Don t show remote cursor Restrictions Local Cursor Shape Normal dot Small dot F View only inputs ignored Disable dipboard transfer
33. CIs cee tee A 22 TECHNICAL Screen 23 OSCILLOSCOPE Screen c occccccccncccnncnnncncnnnnnnanonnnonnano nano nano nnnnnnnnn nara narco nana AEEA nana na nan naa nana 25 SPECTRUM SCr en ui 28 AUTO MOGE EEN 30 8 DUAL SENSORS SCREEN TEMPLATES cccccsscccsesensesecsseneeuesseaceeeuueeeeeseaueeeneeeeseusausauss 30 AE Te EE 31 PA GOTO EE 32 AIN EEN 34 9 MAIN MEN WR 36 10 SYSTEM dE LN 36 VEH Ile 37 Miscellaneous Sels dd tement nie 39 Brightness Settings Ses a A ine Eaei 40 LAN SOTINOS seriada 41 Power SAVING sisas id oia 42 Tim and Date ui ee 44 Backup and Restore ss 45 A une 46 11 SENSOR 1 MENU BEN 48 Sensor Detalla cada 48 Sensor Gables Table 2 22 ls esse ca 48 sensor Gables Calibration iconos aida densnode nusemmestage ss 50 100 Power Levels oooccoocccnccccncccnnccnonaconcnonanonononnanononnnnnconnnnn nano nunn ona rana n nn rca n nano anA nananana 51 Antenna Cables 52 Miscellaneous EE 53 COPY SOINS custodiada son ane 54 microHAM 2015 All rights reserved 12 ALARM TME N U aaa a raa e eaaa sudden cacencdsceseeetecetvasadsavesdsedicensbesceceactsioasssaavediccSeaseedeness 55 Alarms Plandliig and OperalON sidad ici 55 EN LO EE 57 e EI Ee EE 59 LOW POWER ol sereine ora iaa pican Ae RdA aen E dea dadas adem s 60 HIGH POWER Alar iii sia 61 PSK IMD Alarmi o A EA a a Aa ee Ed 62 ARGING Ala mi ada vend codes cota A A di at rares a dave 62 13 DATA STRUCTURE DIAGRAM oooooconnnnnnnnnconennnenn
34. D x EF Forward Power Reflected Power delivered power to the coaxial cable connecting antenna FWDanr E Forward Power Reflected Power actual delivered power to the antenna BAR GRAPHS FUNCTIONS How bar graphs scales and ranges work was already explained now we look at bar graphs functions and settings While settings for top and bottom bar graph are almost identical function sets available for each are much different Please note bar graph function and settings are remembered separately for each SENSOR and each SCREEN It means that you can have different bar graph behavior for every screen or screen copy Anyway when you are happy with new settings and you want to just clone them to another screen or sensor you can copy bar graph settings in SYSTEM MENU SCREEN MANAGEMENT described later To change function of the bar graph you have to enter EDIT mode and select field parameter right next to T BAR or B BAR icon in top STATUS bar depends on if you want to change top or bottom bar function When parameter is selected you can change function by rotating the knob 1 FWD rer TX PK e Peak envelope forward power minus reflected power delivered power at the TX feed point 2 FWD rer TX AVG e Average forward power minus reflected power delivered power at the TX Sensor feed point 3 FWD TX PK e Peak envelope forward power at the TX Sensor feed point A FWD TX AVG e Average forward power at t
35. DD MM YYYY or MM DD YYYY format 9 BATTERY Shows status of internal battery used for RTC powering Battery should last for many years and is replaceable CR2032 when needed when drops below 2 75V DO NA 7 7 23 BAL min 2 CDU 44 microHAM 2015 All rights reserved SYSTEM MENU BACKUP RESTORE Backup Restore menu serves for backups management SMORF provides three 3 separate slots where you can backup your settings All three backup slots can be restored from the computer or exported to the computer or as single file through the web interface These data and the file calls SMORF Config Almost all settings of the SMORF can be backup ed including SCREEN layouts and menu settings however there is one item which is not stored to backups and it is the password For security reasons password is excluded from backups because when backups are exported to the computer file is not encrypted and would be readable Password can be reset in the SMORF menu LAN SETTINGS if you forget it and than changed through the web interface Another item which is stored to backups but internally handled separately are sensors data Sensor s data has its own management SMORF has separate memory for 16 different sensors It means that when you attach new sensor to the SMORF SMORF copies sensor s system and calibration data to its own memory to speed up following power ups when only presence of the sensor is detected When you attach 1
36. F s unique advanced type of alarm Of course detection of real arcing with just sensor is not technically possible but it is possible to detect side effect of the arcing and it is short lasting sudden change of impedance Thanks to high sampling rate and CPU power SMORF can detect these sudden changes on every sample and therefore detect changes lasting just several micro seconds And it is exactly what ARCING ALARM does If SMORF detects sudden impedance change causing SWR to jump above apx 5 it activates ARCING ALARM With alarm enabled it is possible to catch even slightly hot switched relays poorly made or weakly tightened connectors feedline problems or poor bonds at the antenna ARCING ALARM has no settings it can be just enabled or disabled When enabled we recommend to let it break your TX path TX BREAK YES and reset by PTT or MANUAL because tripped ARCING ALARM means that you have some serious problem in T R timing transmission path or antenna which sooner or later results in some kind of damage ARCIHG ALARM 1 ARCING ALARM DISPLAY YES SEE EONO AUTO 3s Tx_ EREAE RESET 62 microHAM 2015 All rights reserved 13 DATA STRUCTURE DIAGRAM SCREEN 4 IN TONE GENERATOR SETTINGS SCREEN SETTINGS 63 microHAM 2015 All rights reserved 14 SENSORS SMORF connects to RF signal by remote sensor Sensor is a box inserted in the transmission line coaxial cable from the source of power
37. GRAPH range is remembered for each SCREEN YES settings makes BAR GRAPH ranges independent for each SCREEN NO uses current BAR GRAPH range on all SCREENS of the sensor BARS DOWNRANGING When bar graphs are in AUTO mode sets timeout for switching to more sensitive ranges TUNE SENSITIVITY Sets sensitivity to the carrier stability variation in amplitude for automatic jump to the TUNE screen Larger the number more stable carrier is required TUNE TRIG TIME Sets how long the stable carrier stability requirement is defined in the TUNE SENSITIVITY must last to accept carrier as a command for automatic jump to the TUNE screen TUNE HOLDOFF Sets how long the TUNE screen will be held on the display when tuning carrier signal disappears After timeout screen returns to the original screen from where it jumped to the TUNE screen 39 microHAM 2015 All rights reserved SYSTEM MENU BRIGHTNESS SETTINGS Sets the brightness of the display and LED BAR GRAPHs to a fixed level or to automatic control according to ambient light Brightness intensity of the display and LED BAR GRAPHs can be set separately BRIGHTHESS SETTINGS LED BAR INTENSITY AUTO FI ED 50 AUTO MIN 26 MAX 186 DISPLAY INTENSITY AUTO FIMED 33 AUTO MIN 567 MAs 168 LIGHT SENSOR 1424 CONTROLS 1 LED BAR INTENSITY Defines control type for BAR GRAPHs intensity AUTO uses user defined MIN MAX ranges and ambient light level FIXED uses fixed int
38. HELP If you are unsure what some parameter means push the rotary knob for short help By rotating knob while you are in the help window you can scroll between all available choices and read at the same time what it means or does Push the knob or EDIT button to register new choice and exit from help window We ve put a lot of effort to make short help available for virtually every item possible to change Once you read this manual completely built in help system should refresh your memory and make you able to set what you want without reaching for this manual again Hope you find the built in help useful TWO POINT MEASUREMENTS TX and ANT subscripts REF When you look at most of SCREENS you certainly wonder what these TX and ANT subscripted suffixes means They present another unique feature of the SMORF called two point measurement Thanks to the calibration correction SMORF provides very accurate measurements related to the outer plane of the LOAD connector at the sensor This point is in SMORF language called TX Feed Point and data measured at this point are shown with TX suffix after the data type like FWD x for the forward power or SWRrx for Standing Wave Ratio Having measured all data at the TX Feed Point SMORF can mathematically work out powers and transmission line parameters at the end of the cable where cable connects your antenna and show what happens there how much power is actually radiated This point is called ANT Feed
39. It simplifies manipulation with both cursors In Free mode both cursors must be controlled separately Turning the knob on selected cursor changes its horizontal time position when pushed and turned it changes its vertical position TONE TONE field is a shortcut to built in Tone Generator START STOP function When icon is lit Tone Generator generates defined output Its output is defined in MAIN MENU TONE GENERATOR and settings are unique for the Oscilloscope screen because Tone Generator is a part of SCREEN settings Just repeating what has already been said Oscilloscope screen has two special SCREEN MENU items 1 ACQUISITION TYPE defines how sampled signal is shown on display when more than one sample per display point is available depends on the time base e MAXIMUM Uses peak value from samples captured for one display point This choice should be used when you want to capture short pulses or you do not want to miss a peak in lower horizontal ranges 26 microHAM 2015 All rights reserved AVERAGE Uses averaged value from samples captured for one display point This choice should be used when smoothness of provided waveform is more important than peaks MIN MAX It is a special acquisition type providing two waveforms on display Lower is related to minimal value of the measured signal higher to peak value of measured signal This choice is useful to visualize noise or hum on measured signal Oscilloscope uses peak
40. NC 22 86 14 11 18 Sets UTC time gt pool ntp org 2 WEB SYNCHRO gt 24h Enables synchronization of the UTC 61 00 15 44 14 internal RTC with internet clock HO reference Next is shown real time ZS HE CHL 22 06 2015 status of the synchronization When WEB synchronization is enabled time is updated once an hour Normally you should see just DOWN and SYNC state but there are more states describing current status which may help for troubleshooting DOWN synchronization is turned off or there is no internet connectivity WAIT RESPONSE RTC is waiting for response from the NTP server This happens when the NTP server is busy or not responding WAIT FOR DNS RTC is waiting for response from the DNS server This happens when the DNS server cannot translate NTP server s name to the IP address usually by miss typed NTP server name RETRY RTC tries to reconnect to the NTP server SYNC synchronized next to the status is shown time date of the last synchronization 3 NTP SERVER Sets address of the time server default is pool ntp org 4 TIME FORMAT Sets time format to 12 or 24 hours 5 LOCAL TIME Set local time shift to the UTC time Next to the shift local time is shown in format according to settings 6 DAYLIGHT Enables disables daylight saving shift for the local time 7 DATE Sets DATE Next to it local date is shown in format according to settings 8 DATE FORMAT Allows to set DATE format to
41. OALARM 2 MENU LISTSTEM MENU To enter MENU system push and hold MENU button 11 for one second to get into the root MAIN MENU tree MENU system has auto exit it means that to exit MENU you have to pass through any branch of the MENU tree until MENU disappears by brief pushes of the MENU button Even thought MENU always starts at root MAIN MENU screen last path through the menu branches is remembered by simple pushing MENU button you get where you was last time This is remembered even if you turn the SMORF off TOP LED BAR MENU and BOTTOM LED BAR MENU have already been explained in the BAR GRAPH SETTINGS chapter as well as TONE GENERATOR and SCREEN MENU in following chapters As was mentioned several times these four menus set parameters which belongs to the each screen separately SENSOR 1 2 and ALARM 1 2 menus are menu items related to the particular sensor and they will be explained later Now we take a look at system menu 10 SYSTEM MENU SYSTEM MENU serves to enter settings and parameters not related to individual screens or sensors but applies to the whole SMORF both SENSORs and all SCREENs It is divided into several sub menus SYSTEM MEHU METER MODE CIMISCELLANEOUS _IBRIGHTHESS OLAN SETTINGS LIPOWER SAVING CAUX PORT TIME DATE C BACKUP RESTORE _ISCREENS MANAGEMENT 36 microHAM 2015 All rights reserved SYSTEM MENU METER MODE METER MODE is important system setting which defines how SMORF has to ha
42. ORF in a same fashion as if you operate its front panel It transfers operator s keyboard keystrokes to the SMORF and sends current screen copy back to operator VNC is slow for real time operation but perfectly suitable for remote navigation through menus or for editing screens thanks to Zero learning curve VNC server in the SMORF has been optimized for free Tight VNC Viewer It can be downloaded from www tightvnc com and is available for Windows and Android platform Another tested free VNC viewer is RealVNC Viewer It can be downloaded from www realvnc com and is available for Windows OS X Linux Raspberry Pi Android and iOS systems e To access SMORF from the viewer first make sure that the SMORF is connected to your local network and has assigned IP address Go to SYSTEM MENU LAN SETTINGS and check if LAN ENABLED is set to YES and STATUS is RUNNING e Start the TightVNC Viewer and type IP ADDRESS from the second line of the LAN SETTINGS screen to Remote Host field in the Viewer Use dots between numbers If you have changed default VNC port address 5900 in LAN SETTINGS add it after IP address separated by two colons e Click Options and set parameters according to screenshot e Click OK and click Connect You should get in 2 ee S ee wom Al A RE LAN SETTINGS YES Keyboard mapping Enter EDIT button M MENU button LEFT Arrow SCREEN button RIGHT Arrow SCREEN button KNO
43. Operating frequency from 1 8 500MHz Signed phase measurement Two points of measurement at the sensor point and at the antenna point Phase measurement between sensors Real time temperature compensation in meter and sensor Dual high speed three color user adjustable auto ranging LED bar graphs with configurable peak hold Every meter and every sensor individually factory calibrated for best accuracy Temperature controlled computer automatized calibration setup makes over 10 000 calibration points in each meter and over 100 points in each sensor Calibrated per port for level frequency phase and temperature Very wide viewing angle sunlight readable high contrast graphics OLED display Multiple user configurable display screens for powers impedance waveform spectrum PSK SO2R User configurable alarms in three importance levels warning alarm fault for two power ranges on per sensor per band basis for SWR Low Power and High Power alerts Connectivity Internet enabled native IEEE 802 3 Ethernet port for remote connectivity Internal web server for simple access from the computer browser for status checking maintenance and firmware updates no drivers no specialized software installation TCP port for high speed remote control applications open protocol High purity DDS based test signal generator single dual tone noise for linearity and bandwidth tests iLINK port for simplified connection to our interfac
44. P ANT Rectangular coordinates R jX complex impedance at the ANT Antenna feed point IMP ANT Polar coordinates Z complex impedance at the ANT Antenna feed point LARGE SCREEN GEA FWO ker TX PE EE SUR Te uni 3390 REF 0 180V Large screen is a screen providing two 2 user configurable measurements when there is no need to monitor many parameters at once rather have non disturbing transparent fast and as large as possible readout of basic parameters Good for contesting or as general screen for users preferring large digits Available measurements 1 FORWARD FWDrx REF Peak envelope forward power minus reflected power delivered power at the TX feed point FWDanrREF Peak envelope forward power minus reflected power delivered power at the ANT feed point FWDrx Forward power at the TX Sensor feed point FWDant Forward power at the ANT Antenna feed point 20 microHAM 2015 All rights reserved 2 REFLECTION REF Reflected power at the TX Sensor feed point e REFANT Reflected power at the ANT Antenna feed point e SWRrx Standing Wave Ratio at the TX Sensor feed point e SWRanr Standing Wave Ratio at the ANT Antenna feed point e RLtx Return Loss dB at the TX Sensor feed point RLant Return Loss dB at the ANT Antenna feed point PSK SCREEN CA EU per TX PFK GS SWR TH FWD 2 282U rex Ti JREF oO 16407 PSK screen is the specia
45. Power types Peak average for forward delivered and reflected power Separate one segment peak hold Adjustable peak attack and decay hold and averaging time SWR 1 00 to gt 15 in 4 semi linear scales Impedance 0 to 100Q for R and Z 100 to 1000 for X and D Simultaneous measurements 4 Tone Generator Type DDS based 32bit precision 21 quarter sine wave look up table Output level 1uV 130mVp p 10 step 1 100 1000uV Frequency 150Hz 9999Hz step 1Hz DDS based Signal type Sine Dual Tone individually adjustable frequencies and levels White Pink noise Sweeps Amplitude frequency in linear or logarithmic scale Mode Continuous single shot 10 9900 ms Frequency accuracy 100ppm Output Flatness 0 15dB THD 0 0028 D A converter 24bit 160ksps 70 microHAM 2015 All rights reserved RF Characteristics RF ports IN1 IN2 IN3 IN4 4x SMA female connector Operating frequency range 1 8MHz to 500MHz Absolute maximum power 26dBm Amplitude dynamic range gt 90dB Phase dynamic range gt 70dB Counter dynamic range gt 50dB Frequency segmentation 10kHz at 1 8 2 5MHz and 49 400MHz 1kHz at 2 5 49MHz 100kHz above 400MHz Ports isolation 2 gt 50dB up to 80MHz 46dB at 145MHz 39dB at 435MHz gt 85dB not muxed Noise floor 70dBm typically Amplitude calibration range 60dBm to 23dBm 34 sel
46. WDant Forward power at the ANT Antenna feed point 2 REFLECTION REF Reflected power at the TX Sensor feed point e REFant Reflected power at the ANT Antenna feed point e SWRrx Standing Wave Ratio at the TX Sensor feed point e SWRant Standing Wave Ratio at the ANT Antenna feed point e RLtx Return Loss dB at the TX Sensor feed point e RLant Return Loss dB at the ANT Antenna feed point Same as the 2TX screen also PA screen has a special SCREEN MENU item LED BARS determining which sensor data will be used for bar graphs Selected sensor is indicated by highlighted bar graph icon on display Important note for phase measurement between two sensors It is absolutely necessary to have all sensor cables exactly same in type and length 32 microHAM 2015 All rights reserved intentionally left blank 33 microHAM 2015 All rights reserved AIN SCREEN 4IN is a very special screen designed to use SMORF as a four channel level phase meter without any sensors This screen is available only in special 4 DIRECT INPUTS meter mode REF Ia E SUR Ta o Ce E 40 28 ie Ta ir 14 59 ir DR r 66 The 4IN screen is a big help for low level measurements Accurate measurements of amplitude and phase on four inputs simultaneously is unique feature of the SMORF you can find only on 4 channel oscilloscopes which are still not as sensitive and accurate as SMORF is not even t
47. a amount transferred between the SMORF and the Remote Control application what can be useful if SMORF is located on remote site where you pay for Internet data amount Remote Control application can work in two forms NORMAL and COMPACT In COMPACT mode it doesn t allow any settings and uses bar graphs settings and first two measurements from the NORMAL mode 68 microHAM 2015 All rights reserved LAT 5 5ms SENSOR1 DISCONNECT BW 174 00B s a PK CONTROLS TOP bar graph functions 1 SESSION NAME Shows name of active session 2 SENSOR Shows active sensor 3 SENSOR 1 2 Selects active sensor Remote Control in COMPACT mode 4 AUTO Sets AUTO sensor mode 5 DUAL Sets DUAL sensor mode 6 TOP BAR GRAPH REF AVG Sets function for the TOP REF 7 PR BARG GRAPH REF AVG 7 BOTTOM BAR GRAPH su Sets function for the ES BOTTOM BAR GRAPH Za 3 8 SETUP ZO Calls Setup window Za 0 9 RESET Z REX Alarm reset button 10 TOP BAR GRAPH E RANGE Zn121 Sets range for the TOP Zar EI BAR GRAPH BOTTOM bar 11 BOTTOM BAR GRAPH Measurements graph functions RANGE Sets range for the BOTTOM BAR GRAPH 12 CONNECT DISCONNECT Connects or disconnects to active session 13 LAT BW Shows current latency and occupied bandwidth Bandwidth can be limited in the Setup 14 SET1 2 3 Calls stored preset When pushed and held current settings will be stored to the p
48. ad or antenna Ifyou are connecting two SMORF boxes to LINK bus of MK2R it is necessary to set radio assignment it defines which SMORF belongs to RADIO 1 ID 1 and which belongs to RADIO 2 ID 2 This METER MODE has been designed to use SMORF with two transceivers each using its own sensor Typical application is to use with two independent transceivers in general but this meter mode is especially useful for SO2R setups with single SMORF meter In this case Sensor 1 is fixed to Radio 1 and Sensor 2 is fixed to Radio 2 Both Power Amplifiers PA1 PA2 drawn on the screen are optional Keep following instructions METER MODE Sensor 1 must be on to SENSOR 1 IN aa RADIO 1 PAI TENSOR rer INDEPENDENT SHARF gal to SENSOR 2 IN RADIOS AND TE IEEE IN3 IN4 and belongs SENSORS This METER MODE is very special and makes SMORF a four 4 channel level phase meter without use of any external sensor METER MODE In this mode only the 4IN MODE available and there are no IHi IN2 INS I settings There are no 4 DIRECT INPUTS ji T T T and ALARM settings as well HO SENSORS graphs scale and range which are intentionally 38 microHAM 2015 All rights reserved SYSTEM MENU MISCELLANEOUS SETTINGS In this menu it is possible to check the version of the firmware serial numbers of internal boards and set various global and user interface settings Settings are applied to both SENSORs and all SCREENs 10 11
49. after restart 8 DATA PORT Sets DATA port default port number is 1234 This port is used by native Remote Control application When SMORF is under external DATA control local operation is disabled and REMOTE is shown on display Data port is protected by password 9 VNC ENABLED Enables or disables internal VNC server VNC server can be also enabled or disabled through the web interface 41 microHAM 2015 All rights reserved 10 VNC PORT Sets VNC port default port number is 5900 Next to port number real time status is shown CLOSED when there is no connection IP address of the client when connected 11 MAC ADDRESS Shows SMORF s unique network MAC address necessary for remote wake up from Remote Control application SYSTEM MENU POWER SAVING This menu allows to set power saving and wake up parameters for OLED display as well as for complete SMORF POWER SAVING SAVER 9 nm UTC TES HODE z zZ DATE TES 36 LOCAL TIME YES on LAN YES CALLSIGH YES on PTT YES microHAN CONTROLS 1 SCREEN SAVER Sets time of inactivity in minutes after which display enters the Screen Saver Mode SMORF exits screen saver automatically when detects power data from the sensor or when any button is pressed Screen saver can be set to blank screen best saving or to two modes displaying moving parameters Parameters can be individually enabled or disabled Available parameters are UTC time DATE LOCAL
50. ally according to actual range Contrary to regular oscilloscopes SMORF provides labeled scale division VERTICAL Sets scope vertical Y axis scale and offset Turning knob changes Vertical Amplitude Offset When knob is pushed and turned it changes Vertical Amplitude Scale Again scale is fully labeled Units of Y vertical scale can be changed in next right field Volts V are referenced to the characteristic impedance and Watts W or decibels dBm are related to the Forward power at the TX feed point CURSORS MODE SMORF provides two cursors CURSOR 1 and CURSOR 2 for measurements on captured waveform They can work in two modes Tracking and Free mode In Tacking mode indicated by CT icon Y position of the cursor is stuck to the waveform while X position can be adjusted In Free mode indicated by CF icon both X and Y positions of the cursor can be adjusted On screen cursors are indicated by a small square labeled 1 or 2 CURSORS Cursors can be controlled by placing selection to cursor 1 or 2 field Their position in amplitude and time is numerically presented in table on the right side of display Bottom line of the table with A sign shows difference between CURSOR 1 and CURSOR 2 for both amplitude and time Cursors have slightly different control according to their mode In Tracking mode turning the knob on selected cursor changes its horizontal time position When pushed and turned the other cursor changes its time position
51. an trip different alarm levels With low power alarm it is important to realize inverse effect which can be at the beginning bit confusing because as power is decreasing higher alarm level is tripped Lets take again 160m example for explanation You operate barefoot with 100W transceiver and also use an amplifier which needs to be driven by at least 50W to get 1200W output on 160m If PA is over driven it starts to generate unwanted IMD products when it is under driven it generates less power than desired LOW POWER alarm can take care of under drive Maximal POWER UP TO value is set to 48W W PWR is set to 45W A PWR to 40W and F PWR to 35W It means if power is above 48W SMORF will not generate any LOW POWER alarm but if power is lower and is in range from 45 48W it generates WARNING In range from 40 45W it generates ALARM and in range 35 40W FAULT Below 35W it again doesn t generate LOW POWER alarm This first range is useful for low driving power alert when amplifier is bypassed if you are using only one sensor behind power amplifier If you are using two sensors one in front and one behind the amplifier alarm is active all the time Second range maximal POWER UP TO is set to 1150W W PWR to 1100W A PWR to 900W and F PWR to 200W While power will be larger than 1150W everything will be OK and no LOW POWER alarms will be generated However if power drops and be in between 1100 1150W SMORF will generate WARNING indicating slight
52. ble type is important use only good quality 500 coaxial cables For lengths up to 10m 33ft we recommend to use 5 6mm thick cable avoid thinner cables Good quality RG58 is fine They can be bought from electronics part suppliers Mouser Digikey Farnell already terminated with SMA male plugs on each end If you prefer to make them yourself make sure to cut them for exactly same physical length and solder or crimp connectors precisely If you need even longer cables use thick 7 12mm cable double shielded RG 214 is fine again As a termination use SMA female connectors and add short up to 1 5m RG58 or RG 174 cable jumpers terminated with SMA male connectors to each end Avoid adapters 2 Connect sensor to the SMORF using supplied REFERENCE sensor cables Connect radio to the sensor and terminate sensor with 500 dummy load rated for 50W power 3 Prepare transceiver frequencies and power On each band set frequency from the Sensor Cables Table switch mode to CW and set power to 50W If you cannot set 50W power use any lower maximum available power Once you set frequencies and power do not touch frequency and power setting knobs anymore 4 On screen set CURRENT cables to REFERENCE 1 5 On screen set frequency 2 and switch the radio to this band Verify that the frequency on the screen and the radio match 6 Key the radio let output power to stabilize for a second and push the MENU button to take a sample You should see captured
53. can be defined in the BOTTOM BAR MENU on per band basis settings follow the same segmented scale but this time in a same division and ranges as are defined SWR sub scales When bars are configured to show parts of Complex Impedance the two scales printed in between the two LED bars are used Scale above the central line applies to the top bar graph and shows Resistance R or Absolute value of Impedance Z in O 1000 range Scale below the central line applies to the bottom bar graph and shows Reactance X or Phase angle in 100 to 1000 or 100 to 100 range Bar graphs can operate in MANUAL or AUTO RANGE mode ROTARY KNOB 14 is used to select the mode and to select range in MANUAL mode When rotated in CW direction it changes range from the lowest least sensitive to the highest respectively When rotated in CCW direction very last CCW position is AUTO RANGE In AUTO RANGE mode meter switches range upward immediately but down ranges with timeout BARS DOWNRANGING timeout is adjustable in SYSTEM MENU MISCELLANEOUS if you don t like the default value When rotary knob is depressed and rotated it changes ranges for bottom bar in a same manner as for top bar In MANUAL mode it is possible to overload current range Overloaded range is indicated by fast flashing SCALE indicator 3 Each range allows 2 overload without overload indication Since bar graphs are software driven there is no damage even if they are hugely overloaded for a l
54. ce for Oscilloscope screen or display type for Spectrum screen These specific data will be explained in individual SCREEN TEMPLATE chapters here we describe common settings for all screens 1 AVG ATTACK DECAY e Sets averaging time constants used for average values AVG Range 0 2000ms Step 10ms 2 UPDATE e Sets update rate of numerical AVG values Range 0 1000ms Step 10ms 3 PEAK HOLD e Sets for how long the peak value is kept displayed till resets to new lower peak value Higher peak value overwrites old peak value immediately 4 TUNE JUMP e Enables or disables automatic switching to TUNE screen when SMORF detects tuning signal When this function is enabled SMORF inspects incoming signal waveform and if waveform matches defined criteria for tuning detection automatically jumps to the TUNE screen When tuning signal disappears waveform changes character screen returns back from TUNE to original screen Alarms settings and adjustments will be described in details in separate chapters but now it is necessary to put in some introduction SMORF has built in five 5 type of user configurable alarms in three 3 importance levels Each alarm importance level Warning Alarm Fault can be individually configured for related action visibility audibility and TX break for two power levels on per sensor per band basis There are three 3 commonly used alarms SWR Alarm High Power Alarm and Low Power A
55. ctive sensor s FWD and SWR values at the TX point LOGOUT Disconnects from the web server and locks access Since there is a lot of variation how different browsers work it is possible that some function may not work correctly In this case we recommend to use Mozilla Firefox which is always tested for full functionality 1 y 192 168 2 1 firmware htm x C D 192 168 2 1 firmware html sis Firmware It is recommended to have recent firmware version installed To start update process select proper upgrade file and click Update Always backup your config to a file on PC before firmware update We Sem A EE www microham com SEC ENERO Choose File No file chosen Update Backup config by clicking here Restore config Select file Choose File No file chosen Update RESET SMORF NOW Di 192 168 2 1 confightml x C D 192 168 2 1 config html de Config Backup Restore Configuration Backup config Download Restore config SOARES Choose File No file chosen Y pload Reset SMQRF RESET SMORF NOW 192 168 2 1 status html x e C D 192 168 2 1 status html Q XP m Status FWD 0 000W SWR 1 00 66 microHAM 2015 All rights reserved If there is any need to change something in the SMORF s screen settings or menus remotely it is a task for VNC Server VNC server in the SMORF allows remote operation of the SM
56. d ENABLE attribute which can be set to YES or NO When attribute is set to YES screen is included in screens sequence accessed by SCREEN lt and buttons SENSOR 2 SCREENS ORDER menu does SCREEN om e the same as SENSOR 1 SCREEN ORDER NAME but for the SENSOR 2 instead of STAR CU SENSOR 1 LARGE Si EBRE ss TWO SENSORS SCREENS ORDER menu ado does again the same but for two sensors SCOPE screens when the SMQRF is switched to the SPECTRUM Ei DUAL mode therefore these menu items will not be described separately 46 microHAM 2015 All rights reserved SYSTEM MENU SCREENS MANAGEMENT COPY SCREENS SETTINGS This menu allows to copy screen s data TOP BOTTOM LED BAR TONE GENERATOR ALARM s table of the SCREEN SETTINGS from the current screen to the another screen of the same or the other sensor Screen template specific data in SCREEN SETTINGS menu are not copied if destination screen template type is different to current copy source Rest is copied COPY SETTINGS COPY RREHT Ehron LED BAR SETTINGS TO SZ E STANDARD SCREEN OF SENSOR CONTROLS 1 DATA Sets data going to be copied ALL copies TOP LED BAR settings BOTTOM LED BAR settings TONE GENERATOR settings and ALARM table at once TOP LED BAR copies TOP LED BAR settings BOTTOM LED BAR copies BOTTOM LED BAR settings TONE GENERATOR copies TONE GENERATOR settings
57. d level is below the frequency lock level rise amplitude of each signal separately until it locks Phase measurement is principally not possible different frequencies If you are going to measure three or four signals of the same frequency you can use any inputs If measured level is below the frequency lock level rise amplitude of the signal going to IN1 and IN3 inputs first until they lock For a phase reference you can set any input 4IN screen has a special SCREEN MENU item 50WPM synchronization detection When this function is enabled SMORF tries to find a string of 50WPM dots in the input signal It is useful for low level measurement on antennas to recognize keyed signal from the noise or unwanted signals coming to the input When such signal is detected the Syn icon on the display is lit 35 microHAM 2015 All rights reserved 9 MAIN MENU As was already mentioned SMORF has extensive yet still easy to understand MENU system to get access to various settings and parameters MENU system has a tree structure always starting from the root MAIN MENU having separate branches for global settings SYSTEM MENU sensor related settings SENSOR 1 2 MENU alarms settings for each sensor ALARM 1 2 MENU and four 4 MENU items for each SCREEN TOP LED BAR BOTTOM LED BAR SCREEN MENU and TONE GENERATOR MAIN MEHU m TOP LED BAR CIBOTTOM LED BAR CiSCREEH MERU TOHE GENERATOR LISENSOR 1 MENU CIALARM 1 MENU LISENSOR 2 MENU C
58. e is that SENSOR 1 menu is associated to the SENSOR 1 and SENSOR 2 MENU is associated to the SENSOR 2 further description of the SENSOR 1 MENU can be directly applied to the SENSOR 2 MENU and it won t be described separately SENSOR 1 MEHU SENSOR DETAILS CISENSOR CABLES CIPOWER LEVELS 166 CJANTEHHA CABLES CIMISCELLANEOUS CICOPY SETTINGS SENSOR MENU has several sub menus which logically divides sensor settings into several groups SENSOR 1 MENU SENSOR DETAILS SENSOR DETAILS menu item is informative only Provides these information MODEL Sensor model SN Serial Number of the Sensor CALIBRATION DATE Date of the Sensor calibration CURRENT TEMPERATURE Internal Temperature of the Sensor SENSOR 1 DETAILS MODEL CHF 3 UHF 5H 2 CALTERATIORN DATA 8 86 2615 CURRENT TEMPERATURE 27 C SENSOR 1 MENU SENSOR CABLES TABLE SENSOR CABLES menu provides a table where attenuation and phase difference of the cables connecting the Sensor to the SMORF is defined To understand why this table is important to overall accuracy of the system it is necessary to explain how the calibration is made The SMORF and the Sensor are two separate devices each is individually calibrated for the amplitude and phase SMORF is calibrated to the plane of its IN connectors Sensor is also individually calibrated to the plane of its SMA connectors and to the plane of the LOAD connector If it would be possible to connect Sensor s connector
59. e set in SENSOR MENU When it shows 100 your output power is tuned exactly to where you want to be 4 TUNING PROGRESS DISPLAY e Displays power level progress in time slowly rolling from left to right new values coming from the right Vertical scale is linear in Watts range is set in while dim line near the top shows 100 level It serves as a progress bar and helps to quickly recognize if tuning peak you already had wasn t better than your current tuning peak 5 INSTANT TUNING STATUS INDICATOR e Shows instant status of the tuning by well visible arrow e Outlined DOWN ARROW means that instant peak power is decreasing e Outlined UP ARROW indicates that instant power is rising but its value is lower than the highest already achieved peak BEST FWD PEAK power 22 microHAM 2015 All rights reserved e Filled UP ARROW informs that instant power is rising and at the same time it is the highest achieved peak power BEST FWD PEAK updates to new maximum e CHECKMARK VY means that 100 power level has been achieved tuning is done At the same time SMORF plays the sound notification through internal speaker TUNE screen has special SCREEN MENU setting for the 100 level sound notification Volume of the notification can be set from 0 100 It is worth to note again that to the TUNE screen can be selected manually by and buttons as any other screen but it is also possible to jump here automatically from any other single sen
60. e signal from 150Hz up to 10kHz in 1Hz resolution white and pink noise and amplitude or frequency sweep Generated output signal works in continuous or single shot mode with adjustable time duration Transformer isolated output is compatible with both balanced and unbalanced microphone inputs output level is adjustable over 100dB range in peak to peak volts Output jack contains also open collector PTT keying output always active when generator generates some signal Audio PTT output has large fixed 100ms lead time to prevent any kind of hot switching Internally generator works on DDS principle in 32 bit precision using 2 long sample look up table for quarter period of the sine waveform Output is sent to the differential 24bit D A converter clocked at 160ksps rate 1 OUTPUT e START STOP choice enables or disables generator output When generator is in the SINGLE shot mode output is automatically disabled when generation TIME expires 2 SIGNAL e SINGLE TONE generates single sine wave tone of the frequency defined in FREQ 1 field and of amplitude defined in LEVEL1 field DUAL TONE generates dual tone FREQ 1 and LEVEL 1 fields defines frequency and amplitude of the first tone FREQ 2 and LEVEL 2 fields defines frequency and amplitude of the second tone e WHITE NOISE generates white noise signal of LEVEL 1 amplitude e PINK NOISE generates pink noise signal of LEVEL 1 amplitude e AMPLITUDE SWEEP generates amplitude sweep with li
61. ean signal this screen will help you to adjust your driving level 21 microHAM 2015 All rights reserved TUNE SCREEN MEA FWO ker TH PE GD SR TH BEST FUD PEAK FUD PEAK 2 27W 2 REF 2 po JE TUNE screen is specialized screen helping to tune manual Power Amplifiers or Antenna Tuners It provides two forward power readings 1 reflection measurement 2 ratio of current power to user adjustable 100 power level set in SENSOR MENU displayed in percents 3 tuning progress display 4 and instant tuning status indicator 5 1 FORWARD POWER e BEST FWD PEAK shows maximal peak power in Watts W achieved from the start of tuning and is equivalent to the Total Peak Power TPK power type Resets on exit from TUNE screen switch to another screen either manual or automatic e FWD PEAK shows instant peak power in Watts W and is equivalent to Peak Envelope Power PK type 2 REFLECTION e REFtx Reflected power W at the TX Sensor feed point e REFant Reflected power W at the ANT Antenna feed point e SWRrx Standing Wave Ratio at the TX Sensor feed point e SWRanr Standing Wave Ratio at the ANT Antenna feed point e Rz Return Loss dB at the TX Sensor feed point e RLant Return Loss dB at the ANT Antenna feed point 3 PERCENTAGE e Shows ratio of current power to 100 power level in percents In other words it shows what is your instant power compared to desired 100 power level you hav
62. ected frequencies step 0 5dB Amplitude accuracy 20dBm to 23dBm lt 0 04dB up to 150MHz lt 0 06dB at 250MHz lt 0 09dB at 500MHz 60dBm to 20dBm lt 0 08dB up to 150MHz lt 0 12dB at 250MHz lt 0 16dB at SOOMHz Phase calibration range 180 to 180 34 selected frequencies step 0 9 Phase accuracy 30dBm to 23dBm lt 1 up to 60MHz 1 5 at 150MHz 3 5 at 450MHz 50dBm to 30dBm lt 2 up to 60MHz 3 5 at 150MHz 4 0 at 450MHz Phase range 179 9 to 180 up to 30MHz 179 9 to 170 up to 60MHz 179 9 to 160 up to 150MHz 179 9 to 120 up to 450MHz Power accuracy 0 1 1W 3 1W 600W lt 2 600 3000W lt 2 5 from 1 8MHz to 54MHz CHF 3 0 3 3W 3 3W 2000W lt 2 at 70MHz CVHF 2 0 2 2W 3 2W 2000W lt 2 at 145MHz CVHF 2 0 1 1W 3 IW 400W lt 2 400 2000W lt 2 5 at 435MHz CVHF 2 Ports DC Power 12 15V DC 1300mA max depends on brightness setting iLINK 2x miniDIN6 for proprietary connection to iLINK enabled microHAM devices LAN RJ45 auto MDI MDIX 100BaseTX IEEE 802 3 Ethernet port AUX DIN6 Do not connect reserved for future updates PTT INHIBIT OUT1 OUT2 2x RCA open collector output max 24VDC 100mA PTT IHIBIT IN1 IN2 2x RCA optically coupled input internal 15000hm pullup to 5V SERIAL Native RS232 1200 115200Bd Other Parameters A D converter Synchron
63. ectors Power side 2x N female meter side 2x SMA female Input Return Loss gt 30dB Insertion Loss lt 0 02dB up to 250MHz lt 0 03dB at 500MHz Directivity 35dB at 70MHz gt 30dB up to 500MHz Coupling 60dB at 70MHz 50dB at 250MHz 45dB at 500MHz 50Q loaded Power and phase accuracy lt 0 04dB 1 lt 2 0 6 Operating temperature range 20 to 60 C sensor Weight 500g All sensor parameters are typical 72 microHAM 2015 All rights reserved 17 PACKAGE CONTENTS The product includes one 1 RF VECTOR SIGNAL METER one 1 miniDIN 6 to miniDIN 6 cable 1 5m long one 1 coaxial 2 1mm 5 5mm power plug one 1 4 pole 3 5mm audio plug one 1 Foster 8 female plug and Quick Start User Guide in English language Sensor package contains one 1 Sensor and two 2 individually calibrated sensor cables typically 3m long If the shipment is incomplete please contact your supplier or us at the following address E mail support microham com fax 421 2 4594 5100 by Post microHAM s r o Nadrazna 36 90028 Ivanka pri Dunaji SLOVAKIA 18 WARRANTY microHAM warrants RF VECTOR SIGNAL METER for two 2 years The product must not be modified in any way or the warranty is voided The warranty does not cover damage caused by improper or abnormal use failure to follow instructions improper installation lightning or excessive power The product
64. ensity regardless of the ambient light level FIXED Sets intensity of the LED BAR GRAPHS Please note 0 intentionally does not turn light off but sets them to some minimal usable level AUTO MIN Sets minimal intensity of the LED BAR GRAPHs AUTO MAX Sets maximal intensity of the LED BAR GRAPHs DISPLAY INTENSITY Defines control for the display intensity AUTO uses user defined MIN MAX ranges and ambient light level FIXED uses fixed intensity regardless of the ambient light level FIXED Sets intensity of the display Please note 0 intentionally does not turn display off but sets them to some minimal usable level AUTO MIN Sets minimal intensity of the display AUTO MAX Sets maximal intensity of the display LIGHT SENSOR Shows current ambient light Value is not editable 40 microHAM 2015 All rights reserved SYSTEM MENU LAN SETTINGS This menu serves for setting of everything related LAN SETTINGS to the LAN connectivity and shows real time status LAN ENABLED YES STATUS RUNNING f the network tion of the network connection IP ADDRESS 192 168 i HET MASK 2 255 255 A CONTROLS GATEWAY 192 168 1 DHS ADDRESS 192 162 1 1 LAN ENABLED IP ADDRESS 192 168 1 Enables or disables LAN connection HET HASK 255 255 A YES enables LAN connectivity GATEWAY 192 168 1 Please note ANY change of ANY DHS ADDRESS 192 168 1 parameter in this menu automatically disables LAN connection and must be manually re
65. eration contesting as well as experimenting on antennas amplifiers or matching networks Bottom line Main Display template including all related settings Bar Graphs including all their settings Alarms individually enabled disabled Tone Generator including all its settings forms one SCREEN STATUS BAR On top of each screen status indicators and bar graphs RER aer TX AUS GEEBSUR TX function choice or current antenna cable choice is shown CS P e 1 Frequency validity e Using the calibration data each measured sample undergoes an adjustment procedure which needs to know the frequency of incoming signal therefore is important to see it on all the time If measured signal is very low in power it may happen that the signal is too weak to measure its frequency while its amplitude is still well measurable to show the power In this case the F indicator is off and meter uses last measured frequency e If SMORF is connected to microHAM device over LINK port it receives exact operating frequency from this device even if transceiver is not transmitting 2 LAN port status e Indicates Ethernet port state and connection status e When off SMORF is not connected to LAN e When lit in half brightness SMORF is physically connected to LAN but there is no active connection from a computer e When is fully illuminated LAN port is opened by remote device or computer 3 Serial port status e When lit serial port transfers data
66. es e SNGL Single Shot Acquisition mode Single shot mode is true memory mode It captures waveform of the input signal immediately when it passes the trigger condition Acquisition than automatically stops and waveform stays on display for further analysis To restart capturing move the knob from the STOP icon to the right Icon will show SNGL until after new waveform is captured again 25 microHAM 2015 All rights reserved TRIGGER Sets trigger level While trigger level is adjusted its position is indicated by vertical line on the scope screen and numerical value is shown at A position in the table located on the right side sign is temporary changed to T sign When trigger control is not selected trigger level is still indicated by small T sign on inner left side of Y axis Trigger s horizontal X axis position is always zero 0 but actual zero position on the screen Horizontal Time Offset can be adjusted by the horizontal control Additional trigger settings are available in the SCREEN MENU polarity source HORIZONTAL Sets scope time base horizontal X axis scale and offset Turning knob changes Horizontal Time Offset moves the zero time position trigger across the screen Maximal left position is set by range and sampling memory maximal right position is the right end of screen When knob is pushed and turned it changes Horizontal Time Scale Horizontal scale units are shown in next field and are set automatic
67. es Two keying pass thru ports and RS232 serial port for legacy connections Well featured Auxiliary port for future expansions wall mount 7 segment LED displays analog meter Other features Internal speaker for audible alerts Internet synchronized real time clock Ambient light sensor for display and led bars brightness control Free Remote Control application for Windows and OS X EMI shielded aluminum die cast enclosure Internal processing highlights 210 MIPS 32bit floating point Cortex M4 DSP processor for extremely fast updates and accurate calculation of complex functions hi grade parallel 16bit ADC sampled at 125ksps 24bit DAC at 160ksps for signal generator Both sensors are of the same type U I or FWD REF connected by the same length leads and operating at the same frequency microHAM 2015 All rights reserved 2 IMPORTANT WARNINGS ALWAYS check the polarity of the 13 8 V power supply before you connect it to the meter If you use meter without sensors NEVER exceed 26dBm level to the meter s IN RF ports If you use some accessory injecting DC power to the coaxial cable connect it ALWAYS behind the LOAD port of any CHF sensor DO NOT connect OUT ports to inductive AC or gt 24VDC loads DO NOT place meter on hot surfaces DO NOT touch the sensor under RF power ALWAYS backup your settings prior firmware update 3 HARDWARE DESCRIPTION SMORF system consists of two parts sensor a
68. g in multi transmitter environment it is good to set it for minimal 10mW level 53 microHAM 2015 All rights reserved SENSOR 1 MENU COPY SETTINGS In situations where both sensors are connected to similar or same setups like SO2R it is useful to clone customized settings from one sensor to another in order to save a lot of duplicate adjustments This menu allows to copy selected sensor s data from the SENSOR 1 to the SENSOR 2 If this menu is accessed from the root SENSOR 2 MENU it will copy SENSOR s 2 data to SENSOR 1 COPY SETTINGS COPY SENSOR 1 HiPUR ALARMS TO SENSOR 2 COPY CONTROLS 1 DATA Sets data going to be copied HiPWR ALARMS copies High Power Alarms LoPWR ALARMS copies Low Power Alarms SWR ALARMS copies SWR Alarms PSK ALARMS copies PSK Alarms ARCING ALARMS copies Arcing Alarms ALARM SETTINGS copies Alarm Settings ALL ALARMS copies all Alarms and Alarm Settings 100 LEVELS copies 100 Power Levels Table MISCELLANEOUS copies Miscellaneous Settings SENSOR CABLES copies Sensors Cables Table ANTENNA CABLES copies Antenna Cables Table and Assignment ALL SETTINGS copies all above settings at once COPY Select and push the EDIT button to confirm copy 54 microHAM 2015 All rights reserved 12 ALARM 1 MENU ALARM 1 MENU is a sub menu of the MAIN MENU and serves for all settings related to alarms and protection Actually there are two s
69. he TX Sensor feed point 5 FWD rer ANT PK e Peak envelope forward power minus reflected power at the ANT Antenna feed point 6 FWD rer ANT AVG e Average forward power minus reflected power at the ANT Antenna feed point 7 FWD ANT PK e Peak envelope forward power at the ANT Antenna feed point 8 FWD ANT AVG e Average forward power Power at the ANT Antenna feed point 9 Z TX R e Real part of rectangular coordinates complex impedance at the TX Sensor point 10 Z TX 2 e Absolute value of polar coordinates complex impedance at the TX Sensor point 11 Z ANT R e Real part of rectangular coordinates complex impedance at the ANT Antenna feed point 12 Z ANT Z e Absolute value of polar coordinates complex impedance at the ANT Antenna feed point 13 microHAM 2015 All rights reserved 1 SWR TX e Standing Wave Ratio at the TX Sensor feed point 2 SWR ANT e Standing Wave Ratio at the ANT Antenna feed point 3 REF TX PK e Peak envelope reflected power at the TX Sensor feed point A REF TX AVG e Average reflected power at the TX Sensor feed point 5 REF ANT PK e Peak envelope reflected power at the ANT Antenna feed point 6 REF ANT AVG e Average reflected power power at the ANT Antenna feed point 7 Z TX X e Imaginary part of rectangular coordinates complex impedance at the TX Sensor feed point 8 Z ANT X e Imaginary part of rectangular coordinates c
70. he very expensive models Thanks to this mode you can measure amplitude and phase distribution of your RF boxes as 4SQ units stacks vertical arrays splitters combiners check antenna stacks or receiving arrays for phasing error or even pass band characteristic of the filters preselector or low noise pre amplifier There is a lot of applications just always keep in mind CONTROLS 1 BAR GRAPHS RANGE Sets top limit of bar graphs from 30dBm up to 20dBm 2 INPUT LEVEL UNITS Sets input level units to decibels dBm or current amplitude ratio A A 3 REFERENCE INPUT Sets reference input for current amplitude ratio and phase reading Screen shows power and phase of the signals directly applied to the SMORF s RF IN ports bypassing external sensors Amplitudes are shown at four 4 simultaneously updated horizontal bar graphs as well as their numerical values in dBm right next to the bar graphs Bar graphs have linear 50dB range maximal value can be set manually from 30dBm up to 20dBm in decade increments without any impact to numerical values Measured amplitudes have no low limit everything is shown from the noise floor up to the 23dBm however values below 60dBm are not calibrated Input level readout can be switched from dBm to the current amplitude ratio A A referenced to one of the inputs Reference input then displays 1 00 other inputs show amplitude ratio to the reference input Phases are shown as vertical bar graphs a
71. ical and horizontal axes are fully labeled by actual value not by common value div style for faster readout You won t need to count divisions and multiply by current range you will immediately see where you are We hope you will find it useful and enjoy it EA FWO ker TX PK GREE SR TH CONTROLS 1 MODE Sets oscilloscope operating mode e ROLL Rolling mode In Rolling mode screen scrolls from the right to left while new data appears on the right side Speed of scrolling depends on horizontal timebase 3 Changing horizontal or vertical scale restarts scrolling Scrolling waveform can be stopped anytime by moving MODE selection to the next right STOP position Please note in Rolling mode trigger has no sense and its adjustment is not available e AUTO Automatic Acquisition mode Similar to AUTO trigger setting on common oscilloscopes Screen in the AUTO mode is overwritten every time input signal causes a trigger condition If there is no trigger after a short period the screen starts to be refreshed continuously The consequence is that if the signal disappears even if there was a trigger previously the display is cleared after a short period It is a general oscilloscope screen most suitable for periodic signals e NORM Normal Acquisition mode NORM mode is in behavior very similar to the AUTO mode difference is that when signal disappears waveform stays on display until new signal matching the trigger condition arriv
72. icroHAM 2015 All rights reserved MENU SYSTEM INTRODUCTION In above chapter we mentioned MENU system To edit all parameters tables and functions SMORF has extensive still easy to understand MENU system MENU system has a tree structure always starting from the root MAIN MENU having separate branches for global settings SYSTEM MENU sensor related settings SENSOR 1 2 MENU alarms settings for each sensor ALARM 1 2 MENU and four 4 MENU items for each SCREEN TOP LED BAR BOTTOM LED BAR SCREEN MENU and TONE GENERATOR Push and hold for one second MENU button 11 to enter into root MAIN MENU tree MENU system has auto exit it means that to exit MENU you have to pass through any branch of the MENU tree by repeatedly briefly pressing MENU button until reaching the end of the given branch chain and returning to the main SCREEN In BAR GRAPH SETTINGS chapter we have described TOP LED BAR MENU and BOTTOM LED BAR MENU Now we are going to take a look at last two MENU items coupled to the SCREEN and it is TONE GENERATOR and SCREEN MENU TONE GENERATOR Tone generator can be considered as an independent instrument built in the SMORF It can be used independently and simultaneously with other SMORF functions for many different measurements on transceiver and power amplifier Since Tone Generator is a part of the SCREEN it remembers its settings for each SCREEN separately Output can be set to generate single sine wave and two ton
73. indicator is 4 Any selected power type for top and or bottom bar graph is always shown in W Watt units When bar shows POWER both bars can have independently defined four 4 power ranges and for each power range one of three 3 available colors can be assigned for each band each screen separately These ranges and not related to scale ranges described above they may start and end anywhere from OW up to maximal power Advantage of colored ranges is readability When you set for example 50 100W range to be shown in red color power from 50 100W will always be shown in red color regardless of scale range it doesn t matter if you are in 100W scale or 2000W scale In this way you can make some nicely visible important power areas like optimal driving power for amplifier maximal power to certain antenna etc When bottom bar 2 shows SWR instead of reflected power it is indicated by YELLOW SWR scale indicator 4 SWR has its own specialized scale divided to four 4 linear sub scales in order to achieve fast simple and precise readout SWR from 1 0 to 3 0 the most important section has linear division of 0 05 per bar segment It takes 80 of the bar length SWR from 3 0 to 4 0 has division of 0 2 per segment from 4 0 to 7 0 division 1 per segment while SWR 7 segment is lit when SWR is up to 10 Last but one shows SWR from 10 to 15 last one everything higher than 15 Same as for the power also for SWR four 4 custom color ranges
74. larm and two advanced alarms PSK IMD alarm and ARCING alarm While Alarms settings are individual for each sensor their settings apply to all sensor s SCREENs SCREEN MENU allows further setting individually enable or disable each level of main three alarms SWR Hi Power Lo Power on per screen basis For example in this way you can disable Warning and Alarm level keeping just Faults of SWR or Low Power alarms in specific measurement screens oscilloscope or entirely disable Low Power alarm for PSK screen etc etc as you wish to best fit to your needs To enable YES or disable NO particular importance level of the alarm select required cell in the table and turn the knob WARNING ALARM FAULT SWR NO YES YES Hi POWER NO YES YES Lo POWER NO NO YES 18 microHAM 2015 All rights reserved 7 SINGLE SENSOR SCREEN TEMPLATES In following chapters we are going to describe single sensor SCREEN templates their purpose of use settings and available functions STANDARD SCREEN MA FWO ker TX PE GA SUR TX 1 FWD B HOM 0 000604 Standard screen is a general screen providing four 4 user configurable measurements Each measurement is related to one of two points of measurements TX or ANT has its numerical value UNIT and TYPE UNITS Standard screen supports three 3 configurable power units e Watts W e Decibels referenced to 1mW dBm e Decibels referenced to 1W
75. lifier is already delivering power under these critical dangerous conditions to misbehaving load Breaking PTT line from the radio to amplifier while radio is still driving the amplifier causes even worse situation amplifier is forced to hot switch input and output relay putting even more stress on tube or final transistors and radio is consequently connected to misbehaving load If you like your equipment never do this Proper sequence when SWR gets high is to force radio to stop generating power as quickly as possible Only when radio is not generating any power the PTT line to amplifier can be released or safely switched to receiving state Since SMORF supports configurable function for each input and output there are several usage scenarios according to the radio and amplifier capabilities Best option is to use inhibit output from the SMORF provided your transceiver has INHIBIT input All Yaesu radios as well as Elecraft s K3 K3S and Ten Tec Orion Il have inhibit input Driving inhibit input on the radio is only sure way to disable power generated by transceiver regardless of how radio was switched to transmit 1 Configure OUT to INHIBIT POLARITY NORMAL Normal polarity inhibits power when output is open what is default fails safe operation of all above radios 2 Connect OUT of the SMORF to the inhibit input of the transceiver Further setup depends on other components e Ifyou are connecting SMORF to setup with our Station Master
76. lized screen for PSK operating mode enthusiasts lt supports PSK in all speeds 31 63 128 250 500 providing numerical readout of IMD products together with waveform and spectrum displays Scope display shows vertically auto ranged RF waveform monitor for fixed horizontal time optimized for PSK speed Spectrum display shows relative level of fundamental frequency and first three odd order harmonics of the PSK signal in decibels as a difference to fundamental component Level of these harmonics has main impact to the output signal purity They are shown dimmed when their level is too low to be certain for IMD quantification below dynamic range All measurements on this screen are related to the TX feed point Forward power is fixed in Watt W units type is adjustable Reflections 1 can be set to SWR or REF power Reflected power unit is fixed to Watt W using same type as forward power IMD and spectrum display is updated during IDLE cycles of the PSK transmission during data transfer IMD measurement gets dimmed and spectrum display cleared Below the scope display verbally evaluated quality of the PSK signal Q is located for users not very familiar with IMD figures PSK screen has special SCREEN MENU setting for the PSK speed It can be set to AUTO detection or one of available speeds 31 5 63 128 When speed is set to AUTO update rate of IMD values has half the rate If you like PSK mode and you are interested in having cl
77. losely spaced antenna which is at the moment used at another position for receiving Coupled power is high enough to be detected by sensor and since power is generated from the opposite side of the coupler it has impact to level of reflected sample On U I couplers where U and samples are equal in amplitude under matched conditions it causes false triggering To avoid this issue in multi TX setups SMORF provides adjustable POWER THRESHOLD which sets minimal power necessary to initiate measurements For FWD REF sensors power coming from opposite direction is easy recognizable reflected sample is larger than forward and false triggering is eliminated by software SENSOR 1 MISCELLANEOUS SETTINGS MISUPPRESS OVERSHOOT NO TIME ms 3IPOUER THRESHOLD 74 1 W CONTROLS 1 SUPPRESS OVERSHOOT YES enables overshoot suppressing filter This function is not generally applicable to all screens when enabled Advanced metering screens like the Oscilloscope or the Spectrum screens intentionally do not suppress overshoots Also please note that suppression time larger than 2 3ms will have impact to peak reading amplitude of SSB signals where peaks of such duration are normal 2 TIME Sets time used by overshoot suppressing filter Exact value is specific to every transceiver and can be measured on the Oscilloscope screen Good value to start with is 2ms 3 POWER THRESHOLD Sets minimal power to initiate measurements If you are not operatin
78. ly mistuned or under driven amplifier If drops even lower and be in 900 1100W range it will generate ALARM for higher attention ALARM level is set to generate display alert and if drops even more and be in range between 200 900W it generates FAULT indicating seriously mistuned amplifier Since no LOW POWER alarm is explicitly dangerous TX BREAK is disabled for all levels but FAULT level reset is set to MANUAL to keep alarm pop up window on the screen to not miss it CONTROLS 1 POWER UP TO 1 RANGE Sets the highest power for the 1 power range down from alarms will be generated 2 POWER UP TO 2 RANGE Sets the highest power for the 2 power range down from alarms will be generated 3 W PWR Sets the second margin for the WARNING alarm level Value has to be lower than the power value in the POWER UP TO cell 4 A PWR Sets the second margin for the ALARM level Value has to be lower than the power value in the WARNING cell 5 F PWR Sets the second margin for the FAULT alarm level Value has to be lower than the power value in the ALARM cell If you want to turn some importance levels off set both margins to the same value For example if you don t want to generate alarms for first two importance levels WARNING ALARM in the first power range set POWER UP TO and W PWR margin to same value as has A PWR i e 40W It will looks like 40 40 40 35W and only FAULT will be generated in range from 35 40W Or you can set 40 35 35 35W than onl
79. mber 2 NAME Sets NAME of the Antenna or Antenna Cable 3 L Sets physical length of the cable in meters or feet Units are set in SYSTEM MENU MISCELLANEOUS 4 CABLE TYPE Defines coaxial cable type 5 BAND ASSIGNMENT Assigns cable to one or more bands 52 microHAM 2015 All rights reserved SENSOR 1 MENU MISCELLANEOUS MISCELLANEOUS menu allows to set two operating parameters dre Se S IESEL aer TX PK FEELEN First is an ability to suppress ALC overshoots Virtually every 4 BAI PW tims transceiver generates overshoots at the beginning of LL Lies A transmission until ALC loop stabilizes hundreds us up to LC gt 4 several ms Exact time and amplitude of overshoots can be easily Oscilloscope screen showing ALC overshot on initial SMAQRF has very fast measurement and reliably captures every dot of CW signal bump on leading edge overshoot with multiple samples Once you are aware that this happens it can be annoying to see bumped peak and peak hold values on regular screens every time ALC loop timeouts and transceiver generates new overshoot To help with this problem SMORF allows to turn on filter to SUPPRESS OVERSHOOTS Second parameter helps to deal with false triggering Those who are operating at multi transmitter sites are probably familiar with effect of magic SWR needle on analog power meters This effect is caused by RF energy coupled from the antenna radiating power to the c
80. microHAM 2015 All rights reserved SMORF RF VECTOR SIGNAL METER lt SCREEN RANGE EDIT ALARM 2 MENU SENSOR 1 SENSOR 1 SENSOR 2 SENSOR 2 Auto microHAM fax 421 2 4594 5100 e mail support microham com homepage www microham com Version preliminary 31 October 2015 microHAM 2015 All rights reserved TABLE OF CONTENTS CHAPTER PAGE 1 FEATURES AND FUNCTIONS o occccccocccconoconaccnnanonnccanaronnaconaronnaronaronanronaronnaronnrannn cnn nr rnnarnnarnarananas 4 2 IMPORTANT WARNINGS o cocccococconoconocoonononaronnanonaronancnnnrconarcnnaconaronnacana roca non cnn rn nan nro nan nrnnaraannaaoa 5 3 HARDWARE DESCRIPTION o occocccocccconoconooconarononconaronanconaronanconaronanrnnaronnaronnrnonaronarnn nara nrnarnnanaaos 5 From SITE 6 Rear eases ee se ame ne dede tnt 7 4 INSTALLATION ciar iia illes 8 5 OPERATION AS 9 Sensor Selection ann e one RENESSE nt QU idea tea consenti ee 9 Bar Graphs Scales and WE e E 9 6 SCREEN WEE 11 SCREEN Status B r EE 11 SCREEN ele EE 12 SCREEN Two Point Measurements 12 SCREEN Bar Graph Functions sise 13 SCREEN Bar Graph Settings toa 14 SCREEN Tone Generator 16 SCREEN Screens MENG EE 18 7 SINGLE SENSOR SCREEN TEMPLATES ooccocccocccconononanconaronnnnonaronannonaronanconaronanronarnnaaraanranos 19 HR RR EE 19 LARGE Scr en iii Lanta oran vite tena he vada 20 PSK CIO een en le be ee ee a 21 VINES GHG
81. nd Password It is possible to entirely disable log in ol requirement a e Network Shows DATA and VNC port numbers and allows to disable VNC Server e Backup Restore Allows to backup all SMORF settings and backup slots to one configuration file or restore all these settings from the configuration file back to the SMORF 65 microHAM 2015 All rights reserved 192 168 2 1 config html x 192 168 2 1 config html x E C D 192 168 2 1 config htm User settings Use password Configuration Save G C D 192 168 2 1 config html E Network configuration 1234 etes 5900 VNC enabled MZ Save Configuration FIRMWARE Serves for firmware updates Firmware update can be downloaded from www microham com After download click Choose file button and select downloaded firmware file Click Update During firmware upload do not disconnect SMORF from the power and LAN do not turn it off and do not touch any buttons on its front panel Prior firmware update it is necessary to backup SMORF configuration because firmware update may irrecoverably corrupt data and backups in the SMORF memory Proper procedure is Backup config Update firmware Restart SMORF Restore config Restart SMORF A PON gt Config Backup Restore function at Firmware page is functionally equivalent to Backup Restore function at Configuration page STATUS Shows very simple readout of a
82. nd measurement results to another RS 232 enabled hardware device primarily meant to be connected to ULINK DATA module of the Station Master DeLuxe but principally can be used for connection to any monitoring our automatization hardware device supporting native RS 232 protocol of the SMORF Main attention has been put to LAN connectivity SMORF uses native IEEE 802 3 Ethernet port directly connected to the main CPU not thru Ethernet to Serial convertor bootleneck and allows to utilize high bandwidth for data exchange and low latency of 100MBit s networks On LAN SMORF uses TCP and UDP protocols and provides two internal servers for standard remote access HTTP server is designed for basic maintenance of the SMORF from Internet browser It allows to check current status backup configuration restore defaults change password and update firmware e To access SMORF from the browser first make sure that the SMORF is connected to your local network and LAN ENABLED YES STATUS RUNNING has assigned IP address Go to SYSTEM MENU LAN DHCP TP ADDRESS ee g SETTINGS and check that LAN ENABLED is set to earTciay gt fax tes 1 YES and STATUS is RUNNING a Dr e Type IP ADDRESS from the second line of the LAN SETTINGS screen to the browser Use dots between numbers Type User name and Password to get in A OOOO O O Default access is C D 192 16821 THE User admin SMORF Password admin CONFIGURATION User Sets User Name a
83. nd meter Sensor is a box inserted in transmission line coaxial cable between source of power transceiver or power amplifier and the load antenna Depending on used sensor it provides sample of current 1 and voltage U on transmission line or forward FWD and reflected REF power sample All HF sensors are U I type with current and voltage transformers inside All VHF UHF sensors are FWD REF type directional couplers All sensors have internal micro controller and EEPROM memory for calibration data storage Micro controller measures internal temperature of the coupler and provides these data on request to the meter Meter connects to sensor s sample outputs and measures their magnitude and phase at a rate of 125 000 samples per second as well as internal and sensor temperature Captured data are than corrected by four dimensional calibration tables taken during individual calibration for magnitude phase frequency and temperature for both sensor and meter Meter then further processes the captured data For some type of measurements where high data rate is required alarms oscilloscope and spectrum screens raw data are used For measurements where stability and smoothness is more important data are additionally filtered in various IIR or FIR filters according to their nature Computed results are than provided on meter s front panel or computer screen through Ethernet port Thanks to powerful DSP CPU in the meter and optimized code meter
84. ndle sensors and sets relationship to radios and iLINK bus Setting correct meter mode is essential for proper SMORF functionality especially if you are using more than one sensor more than one SMORF device and connecting them to iLINK bus First default meter mode is SINGLE RADIO SINGLE SENSOR mode Choose this METER MODE if you are using only one sensor connected to the SMORF Power Amplifier PA drawn on screen is optional Keep following setup instructions Sensor must be connected to SENSOR 1 IN ports IN1 IN2 Ifyou are connecting two SMORF boxes to LINK bus of MK2R it is necessary to set radio assignment it defines which SMORF belongs to the RADIO 1 and which belongs to the RADIO 2 METER MODE T MODE SINGLE RADIO SINGLE SENSOR SENSOR 1 SHQRF 2 RADIO ID 1 1 METER MODE Sets meter mode of the SMORF 2 RADIO ID ASSIGNMENT Sets radio assignment for iLINK bus Available choices are RADIO 1 ID 1 and RADIO 2 ID 2 Controls apply to all meter modes Choose this METER MODE if you are using two sensors and both sensors are connected to the different RF ports of the same transceiver Typical application is a HF VHF UHF transceiver Both Power Amplifiers PA1 PA2 drawn on the screen are optional Keep following instructions METER MODE MODE PAL A SENSOR 1 SINGLE RADIO INDEPENDENT SENSORS RADIO TD 1i Sensor 1 must be connected to SENSOR 1 IN ports IN1 IN2
85. near or logarithmic response according to the SCALE field definition and of frequency defined in FREQ 1 field Amplitude is swept from the LEVEL 1 to the LEVEL 2 duration is defined in the TIME filed e FREQUENCY SWEEP generates sweep in frequency with linear or logarithmic response according to the SCALE field definition and of amplitude defined in LEVEL 1 field Frequency is swept from the 16 microHAM 2015 All rights reserved FREQ 1 to the FREQ 2 duration is defined in the TIME field 3 MODE e SINGLE CONTINUOUS If CONTINUOUS generator generates output signal until stopped manually If SINGLE generator generates output only for time specified in the TIME field then stops automatically 4 TIME e Specifies duration of the output signal generation for the single shot mode and specifies the ramp time repetition rate of sweeps Range 10 9900ms Step 10 100ms 5 SCALE e Sets LINEAR or LOGARITHMIC response characteristic for sweeps 6 FREQ 1 e Specifies frequency for the first tone or starting frequency for the frequency sweep Range 150Hz 9999Hz Step 1Hz 7 FREQ 2 e Specifies frequency for the second tone or final frequency for the frequency sweep Range 150Hz 9999Hz Step 1Hz 8 LEVEL 1 e Specifies amplitude for the first tone or starting signal level for the amplitude sweep Range 1uV 130mVp p Step 1 9 LEVEL 2 e Specifies amplitude for the second tone or final signal level for the amplitude
86. nonennnonnnnnnnnnnnnnnn nr ner rrrnnnnrnn nenas erre 63 14 SENSORS EE 64 15 REMOTE CONTROL 00d savavcevensdeceiccactccdutencuesebedsesvastdis 65 ATP Server misent AE E Aiba Sees a dd es ST a Pera de cae Ine ee 65 Mie ege EE 67 Remote Control Application sise 68 16 TECHNICAL SPECIFICATION sasceccceisccsccecsscosdsadecussscedecesseccecccuscctocusecscsssdacdacurencecctuscaccdeassunseeaucts 70 17 PACKAGE CONTENT aeien deriet anaa enaena iaaeao aa ena aa RENE NEESS e EES 73 18 WARRANTY AAA O 73 DECLARATION OF CONFORMITY ssssssssssssnnsnnsnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnen 74 microHAM 2015 All rights reserved 1 FEATURES AND FUNCTIONS SMORF is unique metering instrument the most powerful and accurate in line vector RF power meter to date with accuracy rivaling the professional instruments Has tons of extra features and very high level of user customization to fit every hamshack every operator s needs SMORF connects to RF signal by remote sensor coupler available in several models for power levels from miliwatts up to 15kW and frequencies up to 500MHz HF 6m sensors provide sample of passing current 1 and voltage U on its LOAD port VHF and UHF sensors provide sample of forward FWD and reflected REF power to meter The meter can simultaneously measure two independent signals from any two sensors and shows measurement results on its front panel or computer Main features
87. nsing and switches focus again to the first sensor from which detects power AUTO mode is activated by short push of SENSOR 1 and SENSOR 2 buttons together and is indicated by flashing SENSOR 1 or SENSOR 2 according to last sensor focus AUTO mode is canceled by pushing either SENSOR1 or SENSOR 2 button AUTO mode is useful for multiband HF VHF UHF transceivers where meter automatically switches between sensors according to operating band HF vs VHF or UHF or for SO2R contesting setups where only one transceiver transmits at a time AUTO mode is not available in SINGLE RADIO SINGLE SENSOR and SINGLE RADIO SENSORS IN SERIES METER MODES 8 DUAL SENSORS SCREEN TEMPLATES In following chapters we describe dual sensor SCREEN templates their purpose of use settings and all available functions DUAL mode is activated by longer push and hold of SENSOR 1 and SENSOR 2 buttons together and is indicated by both SENSOR 1 and SENSOR 2 indicators lit DUAL mode is canceled by pushing either SENSOR1 or SENSOR 2 button Please note while single sensor screens can appear in any METER MODE DUAL sensor screens are available only in two METER MODES and are further filtered by particular meter mode selection SYSTEM MENU METER MODE SINGLE RADIO SENSORS IN SERIES TWO INDEPENDENT RADIOS AND SENSORS 30 microHAM 2015 All rights reserved 2TX SCREEN 2TX screen is a DUAL sensor screen providing simultaneous measurements for both sensor
88. nsor s TX port Connect supplied miniDIN6 miniDIN6 cable from iLINK port of the meter to the LINK port on microHAM interface If you have multiple microHAM interfaces and you are unsure where to connect iLINK port please refer to METER MODE chapter for more details If you don t have our interface or you have interface without iLINK port please refer to ALARM SETTINGS chapter for more details This connection is not necessary for SMORF functionality but when used SMORF can protect your TX chain using internal ALARMs Connect power to the meter Connect 13 8V DC power supply to the DC power jack of the meter DC power jack is standard 2 1 5 5 mm power jack use supplied plug if you haven t one Observe the polarity Center is positive shell is negative Use well regulated and filtered power supply capable to provide 1 3A Connect grounding lead from your central grounding point in the shack to the ground terminal screw on the meter Turn power On Flip the power switch on the rear panel After power up meter checks for presence of sensors on its inputs When the meter finds a new sensor it copies calibration data from the sensor s memory to the meter s memory Each sensor has built in a large calibration table transfer of these data to meter may take several minutes Be patient and don t worry it is just a one time procedure and happens only on the very first connection to the ne
89. oints in Watts W dBm or dBW units 2 REFLECTION e REF Reflected power for both TX and ANT points in Watts W dBm or dBW units SWR Standing Wave Ratio for both TX and ANT points RL Return Loss dB for both TX and ANT points 3 VOLTAGE CURRENT e Shows voltage and current for both TX and ANT points pk Peak value of voltage and current e p p Peak To Peak value of voltage and current e rms Root Mean Square value of voltage and current 23 microHAM 2015 All rights reserved 4 TL PARAMETERS e RX Rectangular coordinates complex impedance for both TX and ANT points Z R jx R Resistance Q X Reactance Q e Z Polar coordinates complex impedance for both TX and ANT points Z Z ei Z Impedance magnitude Q Y Phase Rectangular coordinates complex admittance for both TX and ANT points Y G jB G Conductance S B Susceptance S e YO Polar coordinates complex admittance for both TX and ANT points Y YJei Z Admittance magnitude S Phase Rectangular coordinates complex reflection coefficient for both TX and ANT points F Re 7 j Im F Real and Imaginary part of the reflection coefficient F e TO Polar coordinates complex reflection coefficient for both TX and ANT points l Flei T Reflection coefficient magnitude Y Phase 5 REACTANCE EQUIVALENT CIRCUIT e Switches between series s and parallel p reactance equivalent circuit
90. omplex impedance at the ANT Antenna feed point 9 Z TX 0 e Phase value of polar coordinates complex impedance at the TX Sensor feed point 10 Z ANT 0 e Phase value of polar coordinates complex impedance at the ANT Antenna feed point 11 Z TX R jX e Dual display of rectangular coordinates complex impedance R green jX red at the TX Sensor feed point 12 Z ANT R jx e Dual display of rectangular coordinates complex impedance R green jX red at the ANT Antenna feed point 13 Z TX Z 0 e Dual display of polar coordinates complex impedance Z green red at the TX Sensor feed point 14 Z ANT Z e Dual display of polar coordinates complex impedance Z green O red at the ANT Antenna feed point BAR GRAPHS SETTINGS To change bar graph settings you have to enter TOP LED BAR or BOTTOM LED BAR menu We haven t described MENU system yet but these two MENU items have shortcuts from the main display screen so we can do it a bit later To enter in by shortcut you have to go to the EDIT mode by pushing briefly EDIT button and selecting T BAR or B BAR icon in STATUS bar When icon is selected push EDIT button again and you will be directly moved to the TOP or the BOTTOM LED BAR MENU depends if you have pushed EDIT button on T BAR or B BAR icon respectively Bar graph settings for top and bottom bar graph are same only difference is that bottom bar graph has additional settings for SWR colors
91. ong time don t worry if it happens Last but one CCW range position of the rotary knob is percentage range When enabled it is indicated by RANGE indicator 5 This range is useful for instant checking if everything is as should be because 100 power level is always full deflection on linear scale without any range switching 100 power levels can be precisely set on per sensor per band basis in SENSOR MENU according to your specific requirements or available power 100 power level value is also used in TUNE SCREEN optimized SCREEN for tuning manual Power Amplifiers or Antenna Tuners 10 microHAM 2015 All rights reserved 6 SCREENS SMORF provides measurement results in form of SCREENs Every SCREEN is a group of measurements and settings for Main display 8 Bar Graphs 1 2 Alarms 6 and Tone Generator Up to 16 screens can be associated to each of SENSOR1 and SENSOR2 separately The dedicated top 9 gt 10 buttons switch between SCREENSs of one sensor Each SCREEN in the sequence can be turned on or off in the SYSTEM MENU SCREENS MANAGEMENT MENU Internally SCREENSs are built on layout templates The template defines how the measurement results are presented on main display 8 if they are displayed numerically classic digital wattmeter appearance or also graphically oscilloscope spectrum or PSK screens There are several built in templates covering most of situations user can face during regular op
92. or Station Master DeLuxe connect its INHIBIT output to IN port of the SMORF and configure IN to INHIBIT POLARITY NORMAL e H you don t have our SM or SMD but you have amplifier with KEY OUT signal also connect this keying output to IN port of the SMORF and configure IN to INHIBIT POLARITY NORMAL If amplifier has reversed keying output Expert amplifiers set IN polarity to REVERSE e If you don t have either of above connect transceiver s PTT output to IN port of the SMORF and configure IN to PTT function POLARITY NORMAL 57 microHAM 2015 All rights reserved Unfortunately not all transceivers have inhibit input Icom and Kenwood radios generally lack this important feature While with these radios fool proof setup cannot be made there is still some solution better than do nothing In this case it is important to avoid non transparent keying VOX PTT over CAT manual use of MOX button and route all PTT source signals through SMORF Configure IN and OUT ports of SMORF for PTT POLARITY NORMAL Connect OUT to the transceiver PTT input and use IN port as only PTT input port To IN port connect your footswitch or PTT output of your computer interface If you are using our micro KEYER II or MK2R connect LINK port of the SMORF to the LINK port on the keyer Even for radios which don t have inhibit this brings significant advantage because both MKII and MK2R disables all modulation and signal paths CW PTT when they receive
93. oth margins to the same value For example if you don t want to generate alarms for first two importance levels WARNING ALARM in the first power range set POWER FROM and W PWR margin to same value as has A PWR i e 60W It will looks like 60 60 60 90W and only FAULT will be generated in range from 60 90W Or you can set 60 90 90 90W than only WARNING will be generated in range from 60 90W 61 microHAM 2015 All rights reserved ALARM 1 MENU PSK IMD ALARM PSK IMD ALARM is special advanced type of the alarm SMORF makes background DSP analysis on the signal receiving from the sensor all the time and when finds PSK idle tone pattern in incoming samples measures its spectral purity Based on these results can trigger special PSK IMD ALARM PSK IMD ALARM has just one WARNING level there is no reason to make more levels of importance There is just one additional settings which allows to set alarm level based on measured PSK IMD levels PSK IMD ALARM 1 PSK IMD ueprue rot IMD gt 1508 1 ALARM DISPLAY ENABLED OUND AUTO 3s T BREET NO SHZE 18 m RESET AUTO CONTROLS 1 PSK IMD Sets IMD level in dB which causes alarm when exceeds Range is from 45dB up to 15dB For those not familiar with IMD figures lower the IMD number more negative means nicer output signal We recommend to set alarm to 25dB level at least ALARM 1 MENU ARCING ALARM ARCING ALARM is another special SMOR
94. ous parallel 16bit 125ksps Measurements update rate 2000 s in single sensor modes 100 s in dual sensor mode 50 s in 4IN mode Dimensions W 250mm D 210mm H 110mm Weight 2 4kg 1 Requires two sensors 2 Muxed inputs IN1 IN3 IN2 IN4 3 Absolute accuracy to NIST traceable HP438A SN 2517U00290 HP8482A SN 2652A22248 HP8482A SN 1925A05693 for levels from 20dBm to 23dBm and to Keysight U2004A for levels from 60dBm to 20dBm 4 RSS Root Sum of Squares uncertainty for complete system including sensor mismatch sensor calibration sensor cables SMORF calibration and reference power meter uncertainties 71 microHAM 2015 All rights reserved Operating frequency range 1 8MHz to 54MHz U I type Maximal Power 3000W ICAS 1500W CCS RF ports connectors Power side 2x SO 239 meter side 2x SMA female Input Return Loss gt 30dB Insertion Loss 0 02dB 0 04dB from 1 8MHz up to 30MHz lt 0 08dB at SOMHz Directivity 27dB at 1 8MHz 33dB at 3 5MHz gt 40dB from 7MHz up to 30MHz 35dB at SOMHz Coupling 50dB 50Q loaded Power and phase accuracy lt 0 04dB 1 lt 2 0 6 Operating temperature range 20 to 60 C sensor Weight 500g 8 CVHF 2 Operating frequency range 70MHz to 500MHz directional coupler Characteristic impedance 502 Maximal Power 2000W ICAS 1000W CCS RF ports conn
95. power alert Second range minimal POWER FROM is set to 1220W W PWR to 1250W A PWR to 1300W and F PWR to 1500W While power will be lower than 1220W everything will be OK and no HIGH POWER alarms will be generated However if power rises and be in between 1220 1250W SMORF will generate WARNING indicating that the amplifier is being overdriven If power rises even higher and be in 1250 1300W range it will generate ALARM for higher attention ALARM level is set to generate display alert and if rises even more and be in range between 1300 1500W than it generates FAULT indicating seriously overdriven amplifier generating a lot of IMD products Since the HIGH POWER alarm trips dangerous situations TX BREAK is enabled for FAULT levels and reset is set to MANUAL to keep alarm pop up window on screen to not miss it CONTROLS 1 POWER FROM 1 RANGE Sets the lowest power for the 1 power range up from alarms will be generated 2 POWER FROM 2 RANGE Sets the lowest power for the 2 power range up from alarms will be generated 3 W PWR Sets the upper margin for the WARNING alarm level Value has to be higher than the power value in the POWER FROM cell 4 A PWR Sets the upper margin for the ALARM level Value has to be higher than the power value in the WARNING cell 5 F PWR Sets the upper margin for the FAULT alarm level Value has to be higher than the power value in the ALARM cell If you want to turn some importance levels off set b
96. protection alert over iLINK Then only remaining uncontrolled situation is when radio is manually switched to transmit state by MOX button in FSK RTTY mode ALARH 1 SETTINGS WARNING souno 3 CYCLE El LEVEL 113 ALARM SOUND T CYCLE LEVEL 150 9 FAULT SOUND 3 CYCLE 4 LEVEL 180 SPINPUTCINI PTT POLARITY NORMAL OUTPUT OUT 13 PTT POLARITY NORMAL CONTROLS 1 SOUND Selects sound for audible alarm alert 2 CYCLE Sets number of sound repetitions 3 LEVEL Sets volume of the sound 4 TRY Allows to check the sound 5 INPUT Sets IN port function PTT sets IN port to operate as PTT input INHIBIT sets IN port to operate as INHIBIT input 6 INPUT POLARITY Sets IN port active level NORMAL sets IN port active level active PTT IN closed to ground active INHIBIT open REVERSE sets IN port active level active PTT IN open active INHIBIT closed to ground 7 OUTPUT Sets OUT port function PTT sets OUT port to operate as PTT output INHIBIT set OUT port to operate as INHIBIT output 8 OUTPUT POLARITY Sets OUT port active level NORMAL sets OUT port active level active PTT OUT closed to ground active INHIBIT open REVERSE sets OUT port active level active PTT OUT open active INHIBIT closed to ground Please note OUT port is open collector output of the small signal bipolar NPN transistor OUT port is NOT designed to key inductive loads relays or
97. reset 15 MEASUREMENTS Sets measurement type for each one of six measurement positions 16 COMPACT Sets window size to the COMPACT mode 69 microHAM 2015 All rights reserved 16 TECHNICAL SPECIFICATIONS Display Point of measurement Sensor and antenna for all measurements Power range 0 001W to 19 999W 9 99dBm dBW to 72 99dBm 42 99dBW depends on sensor 80dBm to 23dBm in 4IN mode Power types Peak instant average total peak and total average for forward delivered and reflected power Adjustable peak hold time averaging time and update rate SWR range 1 00 99 9 Return Loss 0 99 99dB Phase 180 0 to 180 0 Impedance Real and imaginary part from 0 01 99990 phase from 0 01 to 89 9 Other measurements IZI R X IYI G B T Fl IMD U and I peak p p rms L C Loss Gain Simultaneous measurements 15 Display 256x64 graphic monochrome OLED 3 11 diagonal size 16 intensity levels Bar Graphs Type 2x 51 segments 3 user assignable colors red green yellow Dot or Bar mode Point of measurement Sensor point and antenna point for all measurements Power ranges 5 range multipliers x0 1 x1 x10 x100 1000 and 3 linear scales 10 20 50 for total 14 full scale ranges 1W 20 000W Power ranges mode AUTO manual 100 level adjustable on per band per sensor basis
98. rs EDIT mode and allows editing outlined fields on current screen pressing and holding for one second enters MENU system of the meter SENSOR 1 BUTTON o o when pushed briefly together with SENSOR 2 button meter switches to the AUTO mode and automatically focuses to the first sensor passing sensing nonzero power when pushed and held together with SENSOR 2 for one second meter switches to the DUAL mode and displays special screens designed for two sensors measurements button serves as up navigation button in MENU system SENSOR 2 BUTTON o o when pushed briefly together with SENSOR 1 button meter switches to the AUTO mode and automatically focuses to the first sensor passing sensing nonzero power when pushed and held together with SENSOR 1 for one second meter switches to the DUAL mode and displays special screens designed for two sensors measurements button serves as down navigation button in MENU system ROTARY KNOB O O O 0 0 when rotated sets top bar graph range when pushed and rotated sets bottom bar graph range changes selected value in EDIT mode and MENU system when pushed in EDIT or MENU system it pop ups short help for selected item during ALARM condition push snoozes or resets active alarm AMBIENT LIGHT SENSOR o measures ambient light for automatic brightness control of bar graphs and main display microHAM 2015 All rights reserved 10 11 12 13 14 15 16 17
99. s and entries will be lost and reset to the default Only content of backup slots and sensor s data copies remain intact Once you overwrite factory supplied backup slots you cannot get them back However if you for any reason want to get your SMORF back to absolute default factory state you can download factory default SMORF Config from www microham com downloads page and restore backup slots from the computer through the web interface 45 microHAM 2015 All rights reserved SYSTEM MENU SCREENS MANAGEMENT SCREENS MANAGEMENT menu allows to set appearance of the each screen in the screens sequence and copy screen s data which forms the screen TOP BOTTOM LED BAR TONE GENERATOR ALARM s table of the SCREEN SETTINGS from one screen to another between sensors copy some screen in place of another or create a new screen from scratch based on built in template Menu has several sub menus to simplify data management and user interface SCREENS MANAGEMENT SENSOR 1 SCREENS ORDER CISENSOR 2 SCREENS ORDER CITWO SENSORS SCREENS ORDER CICOPY SCREENS SETTINGS CICOPY COMPLETE SCREEN SYSTEM MENU SCREENS MANAGEMENT SENSOR 1 SCREENS ORDER This menu allows to set if particular screen will be shown in sequence of screens for the selected sensor and allows to customize the NAME of the screen Menu provides table each row is assigned to one screen Screen has own editable NAME screen template TYPE upon which is screen built an
100. s directly to the SMORF s connectors table wouldn t be necessary because only mismatch should be in connectors and it is negligible at frequencies below 500MHz lt 0 01dB 0 025 when properly tightened However the point of remote sensor is to avoid routing bulky antenna cable to operating desk therefore the Sensor and the SMORF needs to be connected together by coaxial cables as sensor provides samples of transmitting signal at its operating frequency Such cables are far from ideal lossless connection and SMORF needs to know how much 48 microHAM 2015 All rights reserved Nature of the coaxial cables is that they have monotone but not linear attenuation characteristic with rising frequency attenuation rises If cables connecting the SMORF are not absolutely same in the electrical length also some phase shift is introduced Both this parameters have huge impact to accuracy and need to be eliminated SMORF can easily null these adverse effects but needs to know the attenuation and the phase shift of cables connecting sensor to meter and in order to be accurate for each frequency separately For this reason each sensor cable is supplied with its own calibration certificate table of the attenuation and relative phase shift for each band Attenuation is exact value of the cable attenuation to plane of its connectors at a given frequency Relative phase shift says nothing alone but when subtracted from the relative phase shift of the
101. s well as their numerical values in degrees left to the bar graphs Phases display is always referenced to one of the inputs and has logical meaning only if frequency of all input signals is the same Please note phase cannot be measured between IN1 IN3 or IN2 IN4 alone It is important to realize that calibration correction factors are applied to input pairs IN1 IN2 and IN3 IN4 separately and that the SMORF needs to know this frequency to show accurate value of input amplitudes SMORF measures frequency on inputs IN1 and IN3 only therefore it is important to make sure that the frequency is locked F icon on status bar is on Frequency counter locks at level of about 35dBm and higher and remains valid even if later signal level decreases Frequency lock updates whenever signal level is above the lock threshold F icon lights up 34 microHAM 2015 All rights reserved Bottom line If you are going to measure just one signal use IN1 or IN3 input on the SMORF If measured level is below the frequency lock level 35dBm rise amplitude first until it locks If you are going to measure two signals of the same frequency use IN1 IN2 or IN3 IN4 input pairs If measured level is below the frequency lock level rise amplitude of the signal going to IN1 or IN3 input first until it locks For a phase reference you can set any one of used input If you are going to measure two signals of different frequency use only IN1 IN3 inputs If measure
102. sensor press SENSOR 1 12 or SENSOR 2 13 button SENSOR 2 focus is indicated by green SENSOR 2 7 indicator When SENSOR 1 and SENSOR 2 buttons are pressed briefly together meter switches to AUTO mode In AUTO mode meter switches focus automatically to the first sensor which detects power Activated AUTO mode is indicated by gently flashing SENSOR 1 or SENSOR 2 indicator 7 AUTO mode is useful for multiband HF VHF UHF transceivers where meter automatically switches between sensors according to operating band HF vs VHF or UHF For SO2R contesting setups where only one transceiver transmits at a time AUTO mode is invaluable When SENSOR 1 button and SENSOR 2 buttons are pushed and held together for one second meter switches to DUAL mode When meter switches to the DUAL mode it provides measurement results of both sensors at the same time Please note AUTO mode and DUAL mode availability depends on selected METER MODE It will be described in details later just to not panic if you can t do it right now BAR GRAPHS SCALES and RANGES Bar graphs in SMORF are well featured and deeply customized indicators capable of displaying much more than just power or SWR The selection of what is actually shown on the bar graph one of available power readings forward reflected delivered all these variants at antenna or parts of the complex impedance or SWR can be quickly set in SCREEN EDIT mode described below Full functionality and se
103. sor screen when SMQRF detects tuning attempt and if that screen has enabled AUTO JUMP TO TUNE screen in its SCREEN MENU All above features provide effective aid to quickly tune your power amplifier or antenna tuner especially when screen is combined with Z TX R jX or Z TX Z complex impedance reading on bottom bar graph TECHNICAL SCREEN So far we have described screens designed for regular day to day operation or contesting Now we are going to describe screens which you normally don t use every day but are extremely helpful for TX signal chain checking troubleshooting experimenting on antennas and matching networks or bench measurements EA FWO ker TX PK GA SR TH L1 Fu 0061 TX ANT 2 980 2 FEF 86 8881 6 666 101 B66Upk LOSS LU 8 BBB UPk IT1 600Apk 8 888AFk ff f TECHNICAL screen is the screen designed to provide complete overview of electrical parameters for both of two point measurement points TX and ANT simultaneously There are total thirteen 13 values for power reflection voltage current complex transmission line parameters as well as series and parallel equivalent circuits Screen is vertically divided to two sides the left side shows measurements at the TX sensor point the right side shows computed values at the ANT Antenna feed point Outlined center field shows losses in the antenna feed line 1 FORWARD POWER e Shows peak power for both TX and ANT p
104. sweep Range 1uV 130mVp p Step 1 10 MONITOR e Enables and sets monitoring level of signal generator output through internal speaker Please note if you do require extreme output signal purity keep it OFF Tone generator output is located at the rear panel at the TEST TONE jack Its output is designed to be directly connected to the microphone jack of all common transceivers however user is supposed to build own cable according to following instructions Jack is 3 5mm 4 pole type Audio uses two poles for microphone signal and microphone ground PTT uses another two poles for PTT and PTT ground PTT ground is internally connected to the system ground of the meter audio ground is isolated Use shielded cable and chart below shield has to be used for PTT ground PTT GND Microphone pin index Signal name Mobile Icom RJ45 jack microphone Desktop Icom Foster 8 jack microphone Kenwood TS 480 RJ45 jack microphone Kenwood amp Elecraft Foster 8 jack microphone Mobile Yaesu RJ45 jack microphone Desktop Yaesu TenTec Foster 8 jack microphone TenTec Foster 4 jack microphone 3 5mm 4 POLE FOSTER 8 RJ45 17 microHAM 2015 All rights reserved SCREEN MENU This menu serves for setting up the SCREEN to meet user requirements SCREEN Menu contains data which are the same but independently adjustable for each SCREEN as well as data specific to particular SCREEN e g trigger sour
105. t power up cycle when SMORF only checks presence of the sensor During run time SMORF takes only temperature measurements from the sensor for real time data correction Sensor communicates to the SMORF over Sensor Cables therefore it is not allowed to insert any device in between the sensor and the SMORF other than plain coaxial cable Please note all U l sensors HF 6m have voltage transformer connected in parallel to the LOAD connector For DC or low frequency AC power transformer winding acts as a short path to ground If you have any controller connected to the antenna feedline which controls some RF Box by injecting DC or AC power to the antenna feedline Ameritron RCS 4 some other antenna switch preamplifier or antenna tuner working on this principle always connect it after the sensor s LOAD connector towards antenna assuming that the radio port of such controller is DC low frequency AC isolated If you are not sure contact your vendor for details For parameters frequency and power ratings of each individual sensor models please refer to the Technical Specifications chapter 64 microHAM 2015 All rights reserved 15 REMOTE CONTROL Last feature described in this manual is SMORF s Remote Control capability For Remote Control SMORF provides three ports AUX SERIAL and LAN AUX port is reserved for future hardware accessories SERIAL RS 232 port has implemented simple protocol in order to provide basic control a
106. ttings of bar graphs will be described in separate BAR GRAPHS SETTINGS chapter here handling of scales and ranges is described At the very beginning one important note to remember Information presented on bar graphs are always related to one sensor either SENSOR 1 or SENSOR 2 according to the SENSOR selection see above In DUAL mode it is possible to select whether the bar graph shows data of SENSOR 1 or SENSOR 2 individually but both bar graphs show data of one sensor Remote Control application on computer shows four 4 bar graphs in DUAL mode Both TOP BAR 1 and BOTTOM BAR 2 has its own POWER reading scale There are three 3 linear scales for each in 10 20 50 full scale divisions and five RANGE multipliers x0 1 x1 x10 x100 x1000 Last x1000 9 microHAM 2015 All rights reserved multiplier is indicated by flashing x100 indicator Bottom power reading scale is shortened to half Final value is given by multiplying indicated value on the current scale by RANGE multiplier Current scale on TOP bar is indicated by one of SCALE indicators 3 and current RANGE is indicated by one of RANGE indicators 5 BOTTOM bar scale is indicated by its own SCALE 4 and RANGE indicator 5 While scale indicators for top and bottom bar are separate range indicators are shared and differentiated by color TOP bar uses GREEN range indicator BOOM bar indicator When RANGE multiplier for both bars is the same rare but may happen RANGE
107. ub menus ALARM 1 MENU and ALARM 2 MENU but since both have same sub menus and settings and only difference is that ALARM 1 menu is associated to the SENSOR 1 and ALARM 2 MENU is associated to the SENSOR 2 further description of ALARM 1 MENU can be directly applied to ALARM 2 MENU and it won t be described separately ALARH 1 MEHU UR ALARH COSETTINGS LILOW POWER ALARH HIGH POWER ALARM PSK IPD ALARM CIARCING ALARM ALARM 1 MENU has several sub menus which logically divides alarms into several groups according to TYPE of the alarm and there is a SETTINGS menu for alarm sound settings and hardware IN OUT configuration Before we get into individual alarm types it is necessary to explain how alarms work and how they are handled ALARMS HANDLING and OPERATION SMAQRF has extremely deep alarms processing and allows to configure alarm conditions and actions for various requirements and situations SMORF provides five 5 different types of alarms simultaneously SWR Alarm Low and High Power Alarm High IMD Alarm for PSK and Arcing hot switch detection Alarm Each alarm type can be globally enabled or disabled Disabled alarm type is disabled for all screens of the sensor We get to alarm types later Each alarm type can trip three different user adjustable levels of importance These levels are WARNING ALARM and FAULT WARNING represents the lowest level of importance ALARM middle and FAULT the highest Higher level alarm has priorit
108. w sensor When done meter will automatically switch to one of the metering screens Select metering mode Press and hold MENU button for a second Using buttons select SYSTEM MENU Press briefly MENU to enter Select METER MODE Press briefly MENU to enter If you are connecting second sensor or both sensors at the same time please refer to METER MODE chapter to understand what metering mode means and does in order to use correct one for your purpose Otherwise select SINGLE RADIO SINGLE SENSOR mode by rotary knob Press MENU briefly to register microHAM 2015 All rights reserved 5 OPERATION Operating SMORF is easy and intuitive but to use it effectively and to maximal pleasure it is important to understand its structure and relationship between data and settings SENSOR SELECTION First basic selection on SMORF is a SENSOR focus If you have only one SMORF u t t E Boe microHAM SENSOR it is just the matter of pressing e w n A onog ogyg po bottom SENSOR 1 button 12 Press EA SON Su A Og a0 Po See bottom SENSOR 1 button briefly to a ROULE D EE vom iad e change focus to that sensor When deg E fssase d mance eo SENSOR 1 is selected red SENSOR 1 e EN a ES indicator 7 is steadily lit 8 yen 150 SENSOR 2 12 13 If SMORF has both sensors installed RF VECTOR SIGNAL METER 1 8 500MHz ne there are more options For manual selection of the
109. xpires It doesn t require output power to cease but if alarm condition is matched when alarm is auto cleared alarm re triggers AUTO reset time can be set to 1 99 seconds This reset is suitable for occasional alarms and low importance WARNING level when there is no risk of damage caused by consecutive alarm tripping e PTT resets alarm when PTT is released and RF power disappears e MANUAL reset requires intentional operator response alarm must be cleared by buttons on SMORF s front panel SCREEN button or knob button snoozes alarm gt SCREEN button resets alarm Alarm can be reset also remotely from the remote control application running on the computer It is recommended to use MANUAL reset for FAULT level of alarms which makes you aware of critical situation especially when combined with TX BREAK action When MANUAL reset is selected alarm pop up window appears even if its appearance is disabled Special reset choice for tripped alarm is snoozing Tripped alarm can be SNOOZED for defined period of time in minutes in the SNZE field 3 If alarm is snoozed and during snooze period the tripping condition is matched alarm is ignored This applies only to same alarm type and same importance level as was snoozed SUR ALARM 1 SWR MARMING ALARM FAULT ALARM DISPLAY YES YES HO SOUND HO YES MO 4 AUTO Leila BREAK HO HO YES SHZE 1m RESET AUTO PIT MANUAL D CONTROLS 1 ENABLE Globall
110. y WARNING will be generated in range from 35 40W 60 microHAM 2015 All rights reserved ALARM 1 MENU HIGH POWER ALARM HIGH POWER ALARM is a third common alarm Same as the LOW POWER ALARM it allows to set three different POWER values to trip three importance levels WARNING ALARM FAULT for each band separately as well as provides two power ranges where different power levels can trip different alarm levels Contrary to the LOW POWER ALARM which trips when power is lower than tripping level the HIGH POWER ALARM trips when power exceeds tripping level Lets take our 160m example once again for explanation You operate barefoot with 100W transceiver and also use an amplifier which needs to be driven by at least 50W to get 1200W output on 160m If amplifier is overdriven it starts to generate unwanted IMD products when it is under driven it generates less power than desired HIGH POWER alarm can watch to not over drive the amplifier Minimal POWER FROM value is set to 52W W PWR is set to 55W A PWR to 60W and F PWR to 90W It means if power is below 52W SMORF will not generate any HIGH POWER alarm but if power rises and is in range from 52 55W it generates WARNING In range from 55 60W it generates ALARM and in range 60 90W FAULT Above 90W it again doesn t generate HIGH POWER alarm up to 2 range POWER FROM value so operating at 100W level without amplifier will not trip any alarm This first range is useful for high driving
111. y and overrides lower level alarm When some alarm type is globally enabled its importance levels can be individually enabled or disabled for each screen separately in SCREEN MENU This does not apply to PSK and Arcing Alarms they have just one importance level and cannot be controlled by the SCREEN MENU only be globally enabled or disabled Every enabled alarm generates visual feedback on the front panel by ALARM light This light goes green on first WARNING level red on ALARM level and flashing red on FAULT level On some screens where real estate allows it there is also alarm icon on the display showing which type of the alarm got tripped Each importance level can be set for different action There are three available actions for each alarm level DISPLAY SOUND and TX BREAK e DISPLAY action enables alarm pop up window to appear on display Pop up window shows alarm type importance level and real time value which caused the alarm There are also two icons for clearing tripped alarm SNOOZE SNZE and RESET SOUND action when enabled generates audible alert for an operator Sound and volume for all importance levels can be set in the SETTINGS menu TX BREAK action breaks power generation by transceiver 55 microHAM 2015 All rights reserved Every tripped alarm needs to be RESET SMORF provides three 3 methods how to reset tripped alarm AUTO PTT and MANUAL e AUTO resets alarm automatically when defined AUTO time e
112. y enables or disables alarm type for all screens of the sensor 2 AUTO Sets time in seconds s for AUTO reset 3 SNZE Sets time in minutes m for alarm snoozing 4 ACTION Sets action when alarm is tripped 5 RESET Sets reset method for tripped alarm 56 microHAM 2015 All rights reserved ALARM 1 MENU ALARM SETTINGS ALARM SETTINGS menu serves for two purposes First to let choose and adjust sound alerts for all importance levels of alarms second for definition of IN and OUT port behavior SMORF allows to choose from four 4 types of sound for audible alarm alerts Each sound can be cycled and adjusted in level Sounds can be set for each sensor individually At the SMORF s rear panel two pairs of RCA jacks are located Each pair belongs to its sensor one jack of the pair is input IN second is output OUT Input can be set for one of two functions PTT or INHIBIT Output can be also set to PTT or INHIBIT function independently of input setting For both input and output active level can be individually set by POLARITY setting Now it is necessary to explain how to use these inputs and outputs On some power meters you can find similar RCA jacks with description to connect one to PTT output of the transceiver and second to keying PTT input of the power amplifier Oh there is nothing worst you can do for your amplifier as well as transceiver When SWR is higher than normal and power meter trips SWR alarm radio and amp