Home

Manual - Wholesale Point

image

Contents

1. overload condition BATLo This is displayed when the battery voltage is low You can use the scale for a while but must recharge the battery soon CAEnd This is displayed when calibration is finished Err 0 A zero point error has occurred C_End This is displayed when the battery is fully recharged 2 0 General Scale Information Read this user manual before using the scale so you understand the operating features Do not overload the scale or throw heavy things on the scale Damage from overloading and abuse is not covered by the guarantee Keep the scale clean with a damp cloth and mild cleaning solution 1 Set the scale on a level solid surface and screw the base feet in or out to bring the bubble to the center of the level 2 Turn the unit on by pressing the ZERO key The beeper will sound the display will show the version number and the battery voltage level dc x xx then goes into the display self check ends with the ZERO annunciator lighting The scale is now ready to use 3 To turn the scale off press the OFF key The scale will turn off automatically after 10 minutes if the scale display is at zero and there is no keypad operation You can set the auto off time in the Configuration menu See A oFF on page 9 There is also a power saving feature After 40 seconds of scale inactivity the scale goes into auto power saving mode and the display shows a small o To wake the scale up place a weight on the scale plat
2. SALTER RATES C3235 Checkweigher User Instructions 1 0 Introduction The C3235 is a checkweighing scale for the rapid indication of over under or acceptable weight in a production environment This manual covers the introduction to the unit its use configuration and calibration Front Panel Figure 1 1 shows the front panel of the unit The front panel includes the display window the annunciators arrayed around the display the four keys and the bubble level SALTER V teres Accept E under Figure 1 1 C3235 front panel NOTE This product is rated to IP54 Care must be taken to ensure that the power mains plug does not become wet If the product is required to be used while plugged into the outlet mains the plug must either be located outside the wet area or must be plugged into a socket which provides suitable IP rating with the plug mated Keys and Annunciators ZERO key Press this key to turn the scale on and zero the display TARE key Press this key to tare the weight on the scale Also accepts the displayed item in the menu structure or during numeric entry OFF key Press this key to turn the scale off F key Use this key to access the Configuration menu Also used in the menu to move between choices Display Messages dc x xx This is the voltage of the battery in volts This is displayed and a beep sounds when the scale is overloaded A weight more than 9 divisions over capacity is an
3. Zero Tracking Off Press the F key to toggle between Zt oFF and Zt on Press the TARE key to accept the displayed choice For small piece weights it is a good idea to leave the Zero Tracking off When you ve made your selection the scale is in counting mode with the Count annunciator lit Follow the steps in the next section to use the scale as a counting scale Counting Operation Enter the counting mode by selecting PCS as the unit of measure This is explained in the previous section If your scale has no pieceweight in memory the Count annunciator will flash If you want to use this pieceweight skip to step 3 below to count items If you need to establish a new pieceweight start at step 1 below 1 While in the counting mode press and hold the ZERO key until The word count appears briefly on the scale then the Count annunciator flashes and six zeroes appear on the display 2 Place a known number of items on the scale platform and press the TARE key Five zeroes appear on the display with the first one flashing Use the F key and the TARE key to enter the number of items on the scale For example To enter 25 you must press the TARE key three times to move the flashing digit to the right three times then enter 2 and 5 so the display looks like this 00025 After the last digit is entered the scale calculates the pieceweight and displays the count on the scale 3 You can now place other similar items on the scale
4. and see the displayed counts If you want to start counting other items with a different pieceweight clear the scale platform and repeat steps 1 and 2 above The minimum pieceweight is approximately 0 0011 pounds This translates to maximum counts of aprroximately 900 pieces per pound of scale capacity A oFF A oFF is the next menu item Use this to enable or disable the auto off function Follow these steps to set this function 1 Press and hold the F key for three seconds to access the Configuration menu rAnGE is displayed 2 Press the F key twice A OFF is displayed 3 Press the TARE key Current setting on or oFF is displayed Press the F key to toggle between the choices If you choose on the scale will automatically power off after 10 minutes If you choose OFF the scale will not automatically shut off When your choice is displayed press the TARE key The function is set and the scale returns to normal weighing mode FILt FILt is the next menu item Use this to enable or disable the auto off function Follow these steps to set this function 1 Press and hold the F key for three seconds to access the Configuration menu rAnGE is displayed 2 Press the F key three times FILt is displayed 3 Press the TARE key Current setting FILT 1 FILT 2 or FILT 3 is displayed This is the filter setting The noisier the environment the scale is in the higher the filter setting you should cho
5. city will flash Load the full capacity weight onto the scale platform and press the TARE key CAEnd calibration end will briefly display then the unit returns to normal weigh mode If you replace the PCB or loadcell the scale requires recalibration If the display shows Err 0 after power up it means there is a problem with calibration Press and hold the TARE key to enter calibration and repeat the calibration process Multipoint Calibration Follow these steps for multipoint calibration of the scale You will need test weights equal to 1 3 2 3 and full capacity 1 12 Place the calibration switch located on the bottom of the scale into the ON position The ON position is when the switch is pulled towards the front of the scale You may need to remove the small cover to access the calibration switch Use a small screwdriver to remove the two screws holding the cover Place the scale on stable level surface and turn the unit on After the self check is complete press and hold the F and ZERO keys until 20 or 100 is displayed This stands for the powerup zero range Repeatedly press the F key to toggle between the two choices 20 and 100 When your choice is displayed press the TARE key Lb or Kg is displayed This is the calibration unit of measure Press the F key to toggle between the two choices When your choice is displayed press the TARE key Scale full capacity is displayed 10 11 Rep
6. e scale will show oFF and return to the normal weighing mode Performing a Checkweighment 1 After setting a lower and upper limit place the item to be weighed on the scale When the weight is stable the weight will be displayed and the Over Under or Accept annunciator will light If the weight is in the acceptable range the beeper will sound 2 Remove the item from the scale and repeat steps 1 and 2 Units Use the Units menu item to set the unit of measure to Lbs Kgs or Grams You can also choose to set the scale to the counting function Follow these steps to set the Units item 1 Press and hold the F key for three seconds to access the Configuration menu If the unit is not in the counting mode rAnGE is displayed If the unit is in the counting mode the display will show Units and you can skip to step 3 below Press the F key Units is displayed Press the TARE key The current unit of measure or PcS is displayed Press the F key to scroll through the choices Lb Lb This is the pounds unit of measure Lb oZ This is the pounds ounce unit of measure PcS This is the counting function HG This stands for KG or kilogram G This is the gram unit of measure When your choice is displayed press the TARE key If you choose a unit of measure the scale returns to normal weighing mode with that unit of measure active and its annunciator lit If you choose PcS the scale shows Zt oFF This stands for
7. eatedly press the F key to scroll through the choices When your choice is displayed press the TARE key The display will briefly show 1 3 capacity 10Lb for a 30 Ib capacity scale and then display 0 Press the ZERO key if the display is not at 0 Load weight equal to 1 3 of the scale capacity on the center of platter and press the TARE key when the display becomes stable 2 3 capacity weight is displayed Load weight equal to 2 3 of the scale capacity on the center of platter and press the TARE key when the display becomes stable Full capacity weight is displayed Load weight equal to 100 of the scale capacity on the center of platter and press the TARE key when the display becomes stable The display shows c 0 with the c flashing At this point you can input a gravity adjustment Press ZERO to increment the factor by one Press and hold the ZERO key for 3 seconds to begin a rapid incrementing of the factor Press ZERO again to stop the automatic incrementing Press F key to decrease the factory by one When you have the factor you want displayed press the TARE key to accept it CAEnd calibration end will briefly display then the unit returns to normal weigh mode Unload the weight and turn off the scale Turn on the scale again to check the accuracy If the scale is not accurate please recalibrate the scale as per above steps If the scale is accurate place calibration switch to the off position and re
8. form 4 lf the battery voltage drops below 5 6V the scale will turn off automatically There is a battery level annunciator on the left side of the display If three of the lights are lit the voltage is 6 3V or higher If two lights are lit the voltage is between 6 0V and 6 3V If only one light is lit the voltage is lower than 6 0V and the unit should be recharged 5 Battery charging Power is supplied by a built in rechargeable lead acid battery 6V 4 5Ah It shows bAfLo when the voltage is low and the scale is at zero The scale can be used for a while but the battery should be charged as soon as possible To charge the battery plug the AC power cord into an appropriate grounded outlet and charge for 12 hours If the scale is unused for a long period of time charge the battery at least every 3 months If after charging the battery life is very short install a new battery 6 If there is no active tare you can zero the displayed weight if it is lower than 4 of full capacity To zero the scale press the ZERO key The ZERO annunciator will light The steps for various kinds of weighing are explained in the following pages To set parameters and calibrate the unit see Accessing the Configuration Menu and Setting Parameters on page 6 and Calibration on page 11 3 0 Gross Weighing 1 Power up the scale 2 Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item s on the scale platfor
9. m 4 Remove the item s and repeat steps 2 through 4 for the next item s 4 0 Tare weighing 1 Power up the scale 2 Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item to be tared on the scale platform 4 Press the TARE key 0 weight is displayed and the TARE annunciator lights 5 Place the item to be weighed on the scale platform Net weight of the item is displayed 6 Remove the item and repeat steps 2 through 5 for other items Removing a Tare Take everything off the scale and press the TARE key 0 is displayed and the TARE annunciator turns off 5 0 Checkweighing 1 Power up the scale N Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item to be checkweighed on the scale platform The weight is displayed and the Over Accept or Under annunciator lights You must set the acceptable window parameters in the Configuration menu which is described in rAnGE on page 6 4 Remove item from the scale platform and repeat steps 3 and 4 for each item to be checkweighed 6 0 Configuration Menu The Configuration menu is shown in Figure 1 2 Normal Mode F key moves gt in the menu TARE key moves 4 in the menu or accepts the displayed value Press and hold ai eae SET 0 9 key for When a choice is made the scale returns to normal weighing mode three seconds Once a choice is made under each parameter the unit returns
10. or flashes and the first digit flashes What you set with the following steps is the lowest acceptable weight for the item to be weighed Remember as you set the values for the lower and upper ranges that the decimal does not appear on the display but you enter the values as if it were For example If you want 2 55 pounds as the lower value enter 02550 on the display 5 Press the F key to increment the digits and the TARE key to accept a digit and move to the next position Repeat this until you ve entered the lowest acceptable weight value The current value for the upper range is displayed the Over annunciator flashes and the first digit flashes What you set with the following steps is the highest acceptable weight for the item to be weighed Remember as you set the values for the lower and upper ranges that the decimal does not appear on the display but you enter the values as if it were For example If you want 2 85 pounds as the high value enter 02850 on the display 6 Press the F key to increment the digits and the TARE key to accept a digit and move to the next position Repeat this until you ve entered the highest acceptable weight value The scale returns to normal weighing mode when you ve finished entering the high value 7 When you select oFF for the rAnGE The scale returns to the normal weighing mode The upper limit should be larger than lower limit If you attempt to set other than this th
11. or oFF is displayed 4 Press the F key to toggle between the choices When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode 7 0 Calibration You can calibrate this scale using single point or multpoint calibration Single point calibration uses just the empty scale and a test weights equal to full capacity to calibrate the scale During multipoint calibration you can choose between a powerup zero range of 20 or 100 and use zero weight 1 3 capacity 2 3 capacity and full capacity test weights Single Point Calibraiton Follow these steps for single point calibration of the scale You will need test weights equal to full capacity 1 Place the calibration switch located on the bottom of the scale into the ON position The ON position is when the switch is pulled towards the front of the scale You may need to remove the small cover to access the calibration switch Use a small screwdriver to remove the two screws holding the cover 11 Place the scale on stable level surface and turn the unit on After the self check is complete press and hold the TARE key until CAL is briefly displayed then 0 Empty the scale and press the TARE key to set the zero point Hg or Lb is displayed Toggle between the choice of calibration weight unit of measure using the F key When the unit of measure you want to use is displayed press the TARE key The full capa
12. ose This means if the scale sits in a place that is subjected to vibrations the higher the vibrations the higher the filter setting 4 Press the F key repeatedly to scroll through the choices When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode Zero Zero is the next menu item Use this to set the automatic zero tracking This means small weights on the scale are zeroed automatically if they fall within the window set under this item Follow these steps to set this function 1 10 Press and hold the F key for three seconds to access the Configuration menu rAnGE is displayed Press the F key four times Zero is displayed Press the TARE key Current setting Zero0 5 through Zero5 0 is displayed 4 Press the F key repeatedly to scroll through the choices Choices are in 1 2 division increments When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode bUZZEr Use this item to set the Accept buzzer or beeper on or off If you choose on the unit will beep when a steady weight is in the Accept range If you choose oFF the beeper will not sound Set using the directions below 1 Press and hold the F key for three seconds to access the Configuration menu rAnGE is displayed 2 Press the F key five times bUZZEr is displayed 3 Press the TARE key Current setting on
13. place the cover If needed assemble the lead seal to lock the seal 13 8 0 Specifications Models Max Cap Division Size Max Tare Accuracy Class Pan size Working Temperature Power Net Weight 14 C3235 3 6 C3235 6 12 C3235 15 30 3kg 6lb 6kg 12 Ib 15kg 30lb 0 5g 0 01 Ib 19 0 02Ib 2g 0 05 Ib 100 lI 7 5 x9 23 95 F 5 35 C 6V4 5Ah rechargeable sealed battery with built in charger 8 Ib UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CANADA This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num rique
14. s de la Class A prescrites dans le R glement sur le _ brouillage radio lectrique que edict par le minist re de2s Communications du Canada 15 C Declaration of Conformity Manufacturer Salter Brecknell Type C3235 corresponds to the requirements of the following EC directives EMC Directive EMC 89 336 EEC Low Voltage Directive LVD 73 23 EEC The applicable harmonised EN60950 EN50081 1 standards are EN50082 1 A copy of the original signed declaration for this instrument is available from Salter Brecknell Weighing P O Box 9533 Smethwick West Midlands B66 2TE Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com 16 January 8 2008 C3235_u fm AWT35 500149 Issue AB
15. to normal mode You must re enter the menu to change another parameter bUZZEr FILt 1 H FILt 2 H FILt 3 Figure 1 2 Configuration menu You use the Configuration menu to set the following parameters rAngE Use this to set the Over Accept Under ranges Units Use this to set the unit of measure and to enter the count mode A OFF Use this to enable or disable the auto off function If enabled the scale will power off automatically after 10 minutes of inactivity FILt Use this to set the level of filtering Zero Use this to set the automatic zero tracking window bUZZEr Use this to enable or disable the beeper How to set each of these parameters is described below Accessing the Configuration Menu and Setting Parameters To access the Configuration menu press and hold the F key for three seconds rAnGE the first menu item is displayed rAnGE Use this item to set the weight ranges which will trigger the Over Accept Under annunciators 1 Press and hold the F key for three seconds to access the Configuration menu rAnGE is displayed 2 Press the TARE key on or OFF is displayed 3 Press the F key to toggle between the choices To enable the range press the TARE key with on displayed Go to step 4 To disable the range function press the TARE key with oFF displayed Go to step 7 4 Ifyou enabled the range function The current value for the lower range is displayed the Under annunciat

Download Pdf Manuals

image

Related Search

Related Contents

Exaco RIGA XL Kit Use and Care Manual  SS&ST 50 SERVICE MANUAL  Humalog, INN-insulin lispro    GBC 4400004 binding cover  Welcome to AutoCAD 2000, AutoCAD 2000 User's Guide    自分だけのリストで閲覧・比較! 全てのデータがここで揃う!    user manual manual de instrucciones manuel - phono  

Copyright © All rights reserved.
Failed to retrieve file