1. ADD ENTER Voltage Power P 5 mode A B Voltage detection terminal connected to two channel Voltage relay A B Independently controlled by pre set Voltage ll
2. set to at 2 When setting is completed press SET key to exit the set state or short press ENTER key to exit directly the system automatically save the parameters waiting for start If cycle times has been set when cycle times over the controller will output a level single as Delay Tba figure 1 it can be used to trigger next controller more controller cascade T1 gt T2 T gt 12 Relay A timing cycle Relay B timing cycle 0 999times cycle P 3 mode running model Relay A B run in turn T1 Relay close release time T2 Relay release close time is opposite to T1 relay status Tab Relay A time over delay Tab time start relay B Tba Relay B time over delay Tba time start relay A Tab Tab set to 0 means A executed immediately start relay B 2 4 P 4 A B dual independent time relay When A and B time relay parameters have been set in P 1 and P 2 mode enter into P 4 mode dual time relay run independently short press the ENTER key to start and stop dual time relay operation Short press SET key to display A timer values short press the ADD key to display B timer values In this mode there are dual voltage detect the input voltage 3v 100 v high level trigger signal can trigger the corresponding time relay to run While timing external switch input does not affect the timer after time over a trigger signal input will start the timing again 2 5 P 5 Dual voltage relay Enter into P 5 mode the control
3. relay A close release after 10 minutes release less than 11 5 V channel B voltage below 10 5 V relay B delay keep open 5 seconds then close 3 minutes release of higher than 12 5 V Setting method first enter into P 1 mode set tl ON 10 minutes time relay A will close 10 minutes and then release then enter into P 2 mode set t1 OF 5 seconds t2 ON for 3 minutes cycle number C001 the time delay B will close after delay 5 seconds then release after 3 minutes finally into P 5 mode setting channel A voltage upper limit for H 12 0 lower limit L11 5 difference between upper and lower higher than the limit to start time relay A a 0 channel B upper limit H 12 5 lower limit L10 5 below the lower limit to start time relay B b 1 setting can be finished by short press ENTER key 2 6 P 6 Display setting and system reset P 6 mode long press SET for three seconds to reset factory setting Short press the ADD key digital LED can be set delay to off 1 9 minutes LED display d 0 means LED will bright any time if you have set the digital LED closing time in the condition of each mode LED will delay shut down automatically press SET key will light up digital LED and delay shut down again control two loads on off AC DC Power O ADD ENTER Voltage Power In P1 P2 P4 mode Use A B voltage detection terminal can trigger A B time relay start timin
4. to start the timer and if the seconds unit the second show the time countdown if minutes unit the last decimal point to 1 Hz frequency flashing in the operation of the means the countdown While timing short press ENTER key to suspend run long press the ENTER key for 3 seconds the return mode selection state 2 2 P 2 Time relay B Setting methods of P 2 mode is the same as P 1 time relay B setting and running is independent of relay A In P 1 P 2 mode voltage interface A and B Figure 1 detect the input voltage 3v 100v high level trigger signal that can trigger the time relay to start timing While timing external switch input does not affect the timer after time over a trigger signal input will start the timing again 2 3 P 3 Joint dual time relay P 3 mode work order as time relay A timing or loop 0 999 times then delay with Tab time then time relay B timing or loop 0 999 times then delay Tba time finally stop or repeat the above action A B dual time relay take reciprocating frequency of 0 999 times Timing parameters of time relay A and B is respectively set in P 1 and P 2 mode the P 3 mode you can set delay time Tab Tba 0 1 seconds 999 minutes adjustable relay A and B run reciprocating frequency If in P 1 P 2 mode the setting time relay cycles is 0 means infinite loops but in the dual joint time relay mode P 3 every channel relay will run once single relay never run with infinite lo
5. B P 3 A B dual channel combined time relay in turn P 4 A B dual channel independent time relay P 5 A B dual channel voltage control time relay P 6 Digital LED shut down setting and system reset Connect to power the initial mode selection is displayed as P 0 then press the SET key to select P 1 P 6 modes press ENTER key to enter into the corresponding mode While any mode running press the ENTER key for 3 seconds system return to the mode selection state 2 1 Time Relay Mode A P 1 Press the SET key to select P 1 controller system will enter into the time relay mode P 1 P 2 0 1s 999 minutes can be set Cyclic run Time relay mode the user can set T1 and T2 time and relay s state such as set T1 status as ON relay close 5 seconds T2 status with OF release 10 seconds cycle vaule is 0 the relay will close for 3 seconds and then release for 10 seconds infinite loop If you set the T1 as OF release at T2 time relay s state will switch to ON automatically Set the cycle number the relay release after cycles over Short press ENTER key to restart cycle When the timer running press ADD key to switch between countdown time and cycles display short press ENTER key to switch countdown time and suspended display A single run If you set the time T1 only T2 is 0 the timing will stop after T1 time over no longer run cycle this can be used as a t
6. EAZY VLC Controller User s Manual Thank you for using this product of our company The EAZY VLC controller can be achieved of the joint action with dual relay by adjusting the timer each time relay can run independently there also can run in turn dual time relay can be controlled by detect dual channel voltage such as control two loads simultaneously or alternately on off single phase motor positive and reversion according to the timing or DC motor positive and reversion or dual solenoid valve timing work in rotation controlled pneumatic or dual alternating bright lights and so on In case of any printing or translation error we apologize for the inconvenience Product Features 1 Digital LED display set by three keys simple powerful has reset function 2 High performance microcontrollers industrial grade reliability high process stability low power digital display can be automatically turned off the minimum operating current at 7mA 12V with reverse power protection surge current shock 3 Each group of relay contacts to a common and normally open normally closed two sets of conversion 4 Dual time relay timer range 0 1 seconds 9999 minutes adjustable close release cycles is adjustable from 0 to 999 0 means infinite loop timer relays can be set to close first or release first 5 Dual relay can take turns running after the end of timer relay A then timer relay B began to run turn the cycle can be
7. g switch signal connect to power VCC PNP type approach switch photoelectric switch NO line access to A B voltage detection terminal DC motor positive and reversion AC DC Power Control of DC motor positive and reversion when A B relay are release the motor s two poles are connected with the cathode of the power supply the motor does not run when the A relay colse The pole of motor anode is connected to the the anode of power the motor run by normal direction when A relay release B Is switched on the motor reverse Attention should be paid to the DC motor can be reversed by reverse pole ADD ENTER Voltage P 3 mode A B Voltage detection terminal input a high level as start and stop signal connect to VCC or external DC3 100V voltage as a voltage signal single phase motor reversing AC MOTOR N f In order to avoid motor stator AC capacitance winding access communication with a phase Interlocking connection O Control of single phase AC motor positive inversion by relay A and B turn on main and auxiliary winding in turn The maximum current 10A 277VAC relay contacts If the motor power is large please Installation with contact RELAY B ADD ENTER Voltage Power P 3 mode A B Voltage detection terminal input a high level as start and stop signal connect to VCC or external DC3 100V voltage as a voltage signal control two loads on off AC DC Power O O
8. imer if the state is set to ON of T1 relay close after T1 time over relay release if T1 is set to OF release after the T1 time delay relay to keep close short press ENTER key the system back to the T1 time start timing Time setting methods n000 0000 save Tl T2 1 Press SET key digital LED flashing display t1 ON means the relay will closed at T1 time at this time press the ADD key to select the OF means the relay will release at T1 time then short press SET key you can set four bit values of T1 short press the ADD key can adjust each number 0 9 then press SET key LED display t2 OF means the relay will release at T2 3 time opposite to T1 state then short press SET key can set values of T2 short press the ADD key the values can be adjusted from 0 9 each number short press SET key again to show C 000 means cycle times press the ADD key to adjust value short press SET key again to LED dose not flash timer parameters be saved short press the ENTER key in setting process also can save timer parameters and exit setting 2 The values of the T1 T2 can switch to minutes unit or seconds unit while setting LED flashing long press SET key for 3 seconds to loosen the decimal point bright on the right of LED means minutes unit if the decimal point dose not bright means second unit Setting over press the ENTER key
9. ler detect DC voltage from A B voltage detection interface Figure 1 Short press ADD show a00 0 means channel A detection of voltage is 0 0 V short press ENTER show b00 0 means channel B detection of voltage is 0 0 V If you have set A and B time relay timing parameters in the mode of P 1 P 2 P 5 mode the controller will 5 detect channel A and B voltage when the voltage exceeds upper limit or set to less than the lower limit system will control time relay A and time relay B run A B two timer parameter of the time relay in P 1 P 2 mode setting then the voltage is lower than the lower limit or higher than the upper limit relay release directly A B two channel of control is run independently of each other if A and B timing parameters of the time relay are 0 then channel A and B voltage detection control relay close release directly without timing In P 5 mode you can set the voltage control upper and lower limit values of channel A B correction upper and lower control state Relay A upper limit lower limit voltage correction control state Relay B upper limit lower limit voltage correction control state Set method short press SET key show the first set of H xx x three numerical and flashing means the upper limit of channel A voltage detection to be set short press the ADD key can adjust 0 9 short press SET key to display the second group L xx x means A voltage lo
10. op In this mode you can also use A voltage detection to trigger the start two relay turns channel A voltage interface trigger mode can be set to high level trigger high level maintenance low level Channel B voltage interface only input high level force to stop and reset timer at ordinary time Set method In P 3 short press the SET key display tab means to set delay time Tab the delay time that end the A waiting for B relay start to run press the SET key again and can set four bit values of Tab short press the ADD each number can be adjusted from 0 9 three seconds long press SET key to switch to minute unit right point light press SET key again to LED display tba means delay values of Tba end of delay B time then press SET key to LED display C000 means A B two relay reciprocating frequency cycle times will be set press SET key to display the at 0 means trigger level signal mode at channel A voltage interface press the ADD key to choose 0 1 2 0 means high level trigger a high level signal trigger running until the time over or press ENTER key to start running 1 means high level maintains running 4 which has a high level to keep running once the level signal disappears dual relay immediately released 2 means low level 0 3v maintains running with a high level will stop running and release the dual relay If you want to run automatically after the power supply connected please
11. triggered by high level or switch to start and forced stop P 3 mode 6 Dual relay which can be run independently can be high or switch to trigger the start P 4 mode 7 Dual voltage detection control relay the detection voltage range DC 0 99 9V each channel can be set to detect movement of the voltage on the lower voltage value DC 0 99 9V All parameter settings can be saved the next time modes and parameters continue to the last running Timer Range 0 1seconds 9999 minutes can be set cycles 0 999 times Voltage detection and voltmeter display range DC 0 99 9 V Error 0 1V Operating Power DC10 16V Relay parameters Coil Voltage DC 12V Two set of conversion normally open and normally closed Contact load 10A 277V AC or 10A 30V DC Contact resistance lt 100mQ 1A 6VDC Mechanical durability 10 millions Electricity durability gt 100 000 10A 250VAC Operating Temperature 40 85 C Set display shut the minimum current values are 7mA 12V delay released Attention Use this product to control the high voltage electrical equipment A N must operate by electrical professionals high voltage danger 49 5 3 NO Normally Open NC Normally Closed Relay close NO connect to COM Relay release NC connect to COM RELAY RELAY B VDD Signal Out GND O O O a ADD ENTER Voltage Power Figure 1 2 Operating modes Mode P 1 Time relay A P 2 Time relay
12. wer limit to be set short press SET again to enter the third group is C 0 0 is voltage correction short press the ADD key to select A voltage detect values correction 0 5 V 0 5 V short press SET again show a 0 means A voltage detection higher than upper limit relay A will close or start timer below the lower limit relay release short press the ADD to adjust to a 1 means voltage is lower than the lower limit relay A will close or start the timer higher than upper limit the relay A release a 2 means voltage higher than the upper limit trigger to start the timer voltage once more than limit even if again below the lower limit will start to the end of the time short press SET again enter into the channel B parameter setting of the relay B then display voltage higher limit and lower limit value correction upper and lower control method setting methods are the same as channel A short press SET key to LED are no longer flashing or short press ENTER key directly at this time enter into voltage detection control status the system display external input DC voltage by voltage interface A and B Figure 1 If upper and lower limit set to the same values such as 12 0 V when the voltage value fluctuates up and down in 12 0 may lead relay on off frequently it is recommended that set voltage limit certain difference between upper and lower limits Example Channel A voltage higher than 12 0V