1.     In case you posses a safe with a fingerscan unit  up to 20 users  with fingerscan can be additionally stored  Users with fingerscan  are identified in the user list of the lock as   USER xxx_FP     The SELO BF   electronics is the first safe electronics  for which  the opening based on fingerscan is certified     At least two opening codes shall be entered to open the safe using  fingerprint  SELO BF    and SELO BFE     Another opening code  must be entered in addition to fingerscan  This can be either  another Fingerscan  SELO BF   only   but also a pin code or an  additional E Key    Allthe fingerscans are stored in the system with a value of 6 12   corresponding to a half value   In order to acquire the  authorization to open  a value of at least 1 must be achieved  A pin  code with a value of at least  2 must be therefore entered for the  opening  a value of 1 can be also achieved with an additional  fingerscan     Attention  The values can be adjusted only using additional software  When  the programming is made on the safe faceplate  the pin code and the E Key  are automatically assigned the value of 1  the fingerscan receives the value of  Ve     Attention  For security reasons as related to programming using the software   it is not allowed to communicate all the opening codes to a single user in case  three opening codes are used  value A fingerscan is 1   2  value B 1 3  value C  1 8      Example    User A has defined his finger in the system as opening code  it
2.    Sicherheitsprodukte Gmbh    Electronic  lock  SELO B    SELO BF      SELO BFE    1       1  Generally    Thank you for deciding for a safe with the SECU  Sicherheitsprodukte SELO B    SELO BF    or SELO BFE 5  You  have acquired a product meeting extremely high security  requirements and developed and manufactured using the latest  technical potential    Please read the entire User Manual before programming and store  it at a safe place for future reference     The electronics is available in a version with a fingerscan unit  SELO BF    SELO BFE   and in another version without the  fingerscan unit SELO B       The present user manual applies to both versions  however  the  menu structure is able to detect automatically the appropriate  version and thus only the menu items intended   for it are active  The items relevant only for the electronics with a  fingerscan unit are marked with       Generally  you can open the safe in three possible ways    e with a code  SELO B      SELO BF    and SELO BFE      e with an E Key  SELO B 5  SELO BF    and SELO BFE   ident  medium E Key not included in the delivery    e with your fingerprint  SELO BF    and SELO BFE        The administrator code when delivered from the factory is  123456  This code must be changed  Additional 9 users with a  code to be entered by the keyboard can be defined  Such code  has always six digits  similarly to administrator    s code     Additionally  up t0 250 E Keys for contactless opening can be  stored 
3.   Save with the On key is displayed     If a user with a value of 1  right to open alone  should be created  the  message FS combination to be confirmed with ENTER must be  followed by pressing the Function key  If the user should be assigned  access in combination with a fingerscan only  this inquiry is to be  confirmed with ENTER     4  Creating a user with an E Key    e Press the On Enter key   e The indication of Code Fingers   is displayed   e Press the Function key   e The Change code menu is displayed   e By pressing the key 2 reach the Administrator menu   e Press the On Enter key   e Admin setup Create user is displayed   e Press the On Enter key   e Create E Key is displayed   e Press the On Enter key   e At this point you are asked to enter the admin  code  factory setting  123456    e FS combination to be confirmed with ENTER    is displayed      Press the On Enter key and accordingly the Function key   e User 00x Store E Key using ENTER is displayed   e Press the On Enter key      E Key in Prog mode  continue with Enter is displayed   e Press the On Enter key   e After confirmation  Save with the On key is displayed        If a user with a value of 1  right to open alone  should be created  the  message FS combination to be confirmed with ENTER must be  followed by pressing the Function key  If the user should be assigned  access in combination with a fingerscan only  this inquiry is to be  confirmed with ENTER     5  Storing a user with fingerprint       e Press
4.  de modifications    BA SELO B 2  SELO BF 2 and SELO BFE2 MD 07 2011      SECU Sicherheitsorodukte GmbH       
5.  the On Enter key   e The indication of Code Fingers   is displayed   e Press the Function key   e The Change code menu is displayed   e By pressing the key 2 reach the Administrator menu   e Press the On Enter key   e Admin setup Create user is displayed   e Press the On Enter key   e By pressing the key 2 reach the Create fingerscan menu   e Press the On Enter key   e At this point you are asked to enter the admin  code  factory setting  123456    e The indication of Create fingerscan is displayed   e The indication of Store finger is displayed   e This procedure is repeated several times   e After a successful entry the indication User xxx successfully created  is displayed       Sicherheitsprodukte GmbH    Made in Germany    www secu gmbh de    SELO B    SELO BF    SELO BFE      4    Attention  When saving a fingerprint it is important that the finger is laid  evenly and in a straight position over the sensor  Follow the instructions on the  display  The finger is saved only when it can be read in an optimum quality     6  Opening with fingerprint     e Press the On Enter key   e The indication of Code Fingerp is displayed   e Move the saved finger over the sensor   e Value not achieved is displayed   e The Code Fingers indication is displayed   e At this point  enter an additional opening code  not Fingerprint with  electronic SELO BFE       e The instruction Please turn knob is displayed    In case following message Is displayed  Value not achieved   an additional  Open
6. ase turn knob implies the action with the knob of  the locking unit  for which the opening code has been entered     2  Changing the administrator code   e Press the On Enter key   e The indication of Code Fingers  is displayed  e Press the Function key   e The Change code menu is displayed   e Press the On Enter key   e The indication of Administrator is displayed  e Press the On Enter key   e The indication of the Old code is displayed   e Enter the factory set code 123456   e Press the On Enter key   e The indication of the New code is displayed  e Enter the new code   e Press the On Enter key   e The indication of Repeat code is displayed   e Enter the new code   e Press the On Enter key   e The indication of Code successfully changed is displayed    3  Creating a user with a code    e Press the On Enter key   e The indication of Code Fingers   is displayed   e Press the Function key   e The Change code menu is displayed   e By pressing the key 2 reach the Administrator menu   e Press the On Enter key   e Admin setup Create user is displayed   e Press the On Enter key   e Create code is displayed   e Press the On Enter key   e At this point you are asked to enter the admin  code  factory setting  123456    e The indication of User 00x is displayed   e Please enter the user code and confirm it with ENTER   e Press the On Enter key   e FS combination to be confirmed with ENTER    is displayed   e Press the On Enter key and accordingly the Function key   e After confirmation
7. e g  dates of birth  or other data  for which a  link can be derived to the code owner  should be used for  coding     e If the code is stored in writing  such document should be  e consistently stored safely  so that it is accessible only to the  authorized persons        Sicherheitsprodukte GmbH    Made in Germany    www secu gmbh de    SELO B   SELO BF    SELO BFE      2       Attention  Any changes of the administrator code and of the user  codes shall be made with the safe door opened     e When the locking system has been reset to another code  this  new code should be repeatedly used with the safe door opened     1 1 Description of basic functions    You can program your lock based on the following description    You can see the programming instructions on the display  To program the  lock  enter into the menu   please press the    Function    key  when the symbol     M    is displayed  You can move within the menu using the keys    1    scroll up   symbol on display  and    2    scroll down  symbol on display   When the  symbol     lt     is displayed  you can use the    Function    key to skip to the next  higher menu level  and choose a particular menu   item using the    Enter On    key     The battery symbol indicates the current battery status   Wie  Battery full      m  Battery empty  please replace the batteries     1 2 Description of programming and user mode    Please find the menu structure shown on the following pages  Also the  navigation is indicated  Add
8. in a way allowing more  surface area to    place to the center and repeat  Place your finger centrally  over the sensor       Sicherheitsprodukte GmbH    Made in Germany    www secu gmbh de    SELO B   SELO BF    SELO BFE      5    1 5 Menu structure       Menu Sicherheitsprodukte GmbH          Made in Germany          www secu gmbh de                                           Input    SELO B   SELO BF    SELO BFE      6    1 6 REPLACING THE BATTERIES   As soon as the symbol depicting the battery condition indicates     almost empty     the operator is also warned Please replace  batteries  each time the lock is operated  We recommend  you heed the advice and change the batteries  The lock can  only be unblocked a further  approximately  50 times   Please note that none of the number codes can be changed  until a set of fresh batteries has been fitted  To change the  batteries  lift off the cover of the battery compartment with  the tip of a screwdriver  Fit three leak proof  type Mignon  LR6  AA  alkaline batteries  paying attention to the correct  polarity  Dispose of the old batteries in accordance with  anti pollution legislation           Sicherheitsprodukte GmbH    Made in Germany    www secu gmbh de    SELO B   SELO BF    SELO BFE           SECU Sicherheitsprodukte GmbH  Wormgerm  hle  D   58540 Meinerzhagen    Germany    www secu gmbh de    mail secu gmbh de    Irrtum und   nderungen vorbehalten  Omissions and changes reserved    Sous r  serve de fautes d   erreurs et
9. ing code shall be entered   When the programming is made using the  software only  When programming using the safe electronics  the indication  Please use rotating knob is displayed already when the second opening code  has been entered      7  Deleting a finger       e Press the On Enter key   e The indication of Code Fingers   is displayed   e Press the Function key   e The Change code menu is displayed   e By pressing the key 2 reach the Administrator menu   e Press the On Enter key   e Admin setup Create user is displayed   e By pressing the key 2 reach the Admin  setup Delete menu   e Press the On Enter key   e Delete user is displayed   e Press the On Enter key   e At this point you are asked to enter the admin  code  factory setting  123456    e Now you have to select the appropriate user by pressing the keys 1  or 2   e Press the On Enter key   e The indication of Delete data to be confirmed with the On key is  displayed    e Press the On Enter key   e The indication of Data record deleted is displayed    Additional users can be deleted using the On Enter key  By pressing the  Function key  you can reach higher menu levels up to the code entry     1 4 Error messages   The following error messages are indicated when a finger is being saved or  the safe opened     too fast  please repeat Move the finger more slowly  over the sensor    Move the finger straight over  too aslant  please repeat the sensor be read    too short  please repeat Move the finger over the  sensor 
10. itionally  each of the menu items is clarified     Code change menu  Change of the administrator and user codes    Language Sprache menu  Language setup    E Key synchronization menu   In this program  the channel of the E Key is adapted to the channel of the  input unit    This function is necessary when the radio channel of an input unit is modified   although other radio keys  with the old channel setup  are still logged     Info menu  Indication of version and serial number  SNA  Lock serial number    Administrator menu   This includes all the menus that can be used only with the administrator   authorizations  They include    3 Create User  Users can be created here  A user has either a code  or an E Key  or  both  A separate user is always created for a fingerscan  Anatomically   there are people  the fingerprints of whom are not sufficiently articulated  for the system     Assign E Key   An E Key can be additionally assigned to a selected user here   Delete   Users and E Keys can be deleted here  When a user is deleted   also the code and the E Key belonging to the user are deleted   When an E Key is deleted  the user is retained  To delete a  fingerscan  the corresponding user has to be deleted  To   delete all the fingerscans  please use the    FS Reset    function  see  below        Time   Entry of the time and calibration of the clock  The clock is  automatically calibrated between two specific times  Exceptions  are a replacement of batteries and the switchover fr
11. om summer to  winter time    Date   Entry of date   Radio Channel   The radio channel can be set up here  12 channels to select  from   This can be required when the radio channel is already  used by another application  e g  WLAN  In case of collision with  WLAN systems  a space of three channels is recommended   Priority    In case the door cannot be opened after several attempts with the  E Key  the priority of the door can be increased by this function   Inversely  also the priority of other door within the direct  environment can be reduced    Restructure    The use of this function is recommended when several users have  been deleted    Register    When either the lock unit or the keyboard is replaced  the two  units are newly tuned to each other    FS Reset     All the stored fingerprints are deleted  however  the corresponding  users are retained  Please select this menu and follow the  instructions on the display also in case of repeated error functions  related to the use of fingerscans        Sicherheitsprodukte GmbH    Made in Germany    www secu gmbh de    SELO B    SELO BF    SELO BFE      3    1 3 Detailed description of selected basic functions    1  Opening the safe using the factory code   e Press the On Enter key      The Code Fingers   indication is displayed    in case you possess  electronics without fingerscan  Code is displayed instead    e Enter the factory set code 123456   e The instruction Please turn knob is displayed    Attention  The message Ple
12. s value is 1     This user can be still authorized in the system with an additional opening code  with a value of 1 3  A user B now needs an additional opening code with a  value of at least 1 3  If a code and or an E Key should be additionally  assigned to a user with fingerscan  it is to be created separately  Inversely   the fingerscan should be assigned separately to a user with a code and or an  E Key        To enable the use of additional functions such as time switching or calendar  functions  you need additional software  Then you will be able to use the  overall user administration     Attention  Should the user data in the safe electronics be administered using  the software  the data must be stored on a removable data carrier  Their  saving in a computer is not admissible  is identified by the system and not  allowed  The removable data carrier should be stored at a safe place  e g  a  safe  after the programming     In order to enhance the protection against intrusion  the following points  should be observed     For locking systems with material code carriers  e g  an E Key     e The code carrier should be consistently stored safely  so that it  is accessible only to the authorized persons       In case of a loss of the code carrier  the lock should be  immediately replaced or converted to a new combination by  changing the coding  and or the code of the lost code carrier  should be blocked deleted     For locking systems requiring a code     e No personal data  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Roxio Toast 12 Titanium User Guide  [PDF(1.22MB)] (日)  pdf  1843-1844-1846  CyberPatrol 7.6 User Manual  Canon PowerShot SD430 Use and Restrictions  Sweex Wireless Laser Mouse  グリーンソーラ  Operators Manual - Superior Truck Equipment Inc.  Prendre Choses Main Mettre Forme    Copyright © All rights reserved. 