1. O WARNING with the system in Maintenance mode the batteries of the system are not charged If the system remains in this mode for an extended amount of time the batteries may be damaged COMMON OPERATIONS FOR ALL CENTRAL UNITS Check if the red LED is on the siren control card If it is lit reverse the connection of the Bus pair WARNING Furthermore make sure the yellow LED is off when it is lit it indicates the alarm condition hence an abnormal condition in the system in this case eliminate the anomaly Now connect the two faston terminals 1 to the battery paying attention to INDOOR SIREN CARD Yellow LED A BUS BATTERY RED BLACK C SOUND SIGNALLER the polarity red black WARNING when there is a connection with an inversion of polarity the card will be protected with 4A fuses placed inside the cable 2 Install the two siren protection covers NOTE in case a second siren is installed make sure to repeat the LED check after its installation The J1 jumper of the second siren must be cut see the siren technical sheet Red LED If central unit L N NT4600 4 is installed move the changeover switch 3 at the back of the unit to the ON position active Fit the central unit inside the box correctly ALLARME 3
2. The application shows the use of the a technical alarm signal managed owner or people indicated by him methane gas detector combined in by the burglar alarm system to close by means of the burglar alarm system by means the solenoid valve and at the same m One or more telephone calls of an auxiliary channel interface time makes a telephone call via the m One or more sms When the detector detects gas by central unit dialling device to the m One or more e mail means of the interface it generates My Home Portal which warns the BURGLAR ALARM LEAL SATS van ei AAA HRA e i i BUS 1 I I I I y I I s l Mere Q ae sae Technical alarm Relay actuator i centralunit i interfe I I I I I I I I I ONL A I I I I I I gt lt I Methane gas Solenoid valve i I I verano detector Telephoneline 1 o 8888888888888888 f I TTT I I I A a9 Transformer i 1 12 Vdc I I I I I I I I I I Note maximum 3 devices with transformer F91 12E maximum 2 devices with transformer HC HD HS L N NT4541 CONNECTIONS AND CONFIGURATIONS Gas detector HC HD HS L N NT4511 12 Technical alarm interface 3481 Note No configuration Note auxiliary channel number 1 must also be indicated while programming the burglar alarm central unit to link it to the telephone communicator signalling message BURGLAR ALARM GEN iin 1 AUX device EE es No of auxiliary channel
3. technical alarm cine To transformer F91 12E 3481 COM R COMC A To the auxiliary channel From methane gas interface detector Burglar alarm MY HOME 211 CONFIGURATION Technical alarms gas leak alarm with burglar alarm system CONNECTIONS AND CONFIGURATIONS Relay actuator 3479 Note the auxiliary channel number 1 is that given in the AUX housing of the technical alarm interface 3481 BURGLAR ALARM Transformer F91 12E 222 3479 CO Pa Solenoid valve 14525 12N0 212 MY HOME Burglar alarm Indoor siren HC HD HS 4070 N NT4070 optional Note The audible signal of the indoor siren does not activate for technical alarms This function is performed by the natural gas detector 2 AUX device CO No of auxiliary channel Egin monostable contact BUS NN ae een EZME Ne mami ere BA 1 Indoor siren technical alarm deactivation D om SEF Technical alarms telephone signalling of the tripping of the general circuit breaker With home switchboards fitted with a breaker As soon as one of the above the MY HOME WEB portal which will SALVAVITA STOP amp GO circuit breaker problems occur the SALAVAVITA then send an alarm message by SMS it is possible to be notified when STOP amp GO device automatically and or e mail the main circuit breaker trips due closes the tripped circuit b
4. Burglar alarm MY HOME 205 CONFIGURATION Use of the Youproject program for the configuration of the system The configuration of the system can be performed using the appropriate design program called Youproject conceived to automatically perform all the specific and predictable functions inside the home automation system placement of devices dimensional and electrical calculation allocation of addresses configuration of tables Youproject program screen with the data of the system to be configured The software produces a paper report with technical information for the installation of the system which also includes the configuration and the list of the necessary materials Report generated by the program with the configuration and the list of devices 206 MY HOME Burglar alarm Technical alarms shop burglar alarm If there is arobbery the assistant can means of local sound alarm so that the robber press a hidden pushbutton which m one or more telephone calls can be surprised as he does not activates the burglar alarm central E one or more sms using the MY know that the call has been made unit telephone communicator which HOME portal Suspend the call by means of the sends areguestfor assistance to the E one or more e mail using the MY remote control on the burglar alarm My Home Portal This will warn the HOME portal central unit owner or people indicated by him
5. L N NT4600 4 AM4600 4 HC HD HS L N NT4601 Minimum No Maximum No Minimum No Maximum No Minimum No Maximum No KEYS IR remote control 1 Not managed Not managed Not managed Not managed Radio remote control 0 0 0 Transponder 0 MAX 30 in total 0 MAX 20 in total 0 MAX 20 in total Numeric code 0 0 0 ACTIVATORS AND DIVIDERS Keypad connector with display 0 0 0 Keypad connector 0 9 for each zone 0 4 0 9 for each zone 0 4 0 9 for each zone 0 4 total total 45 total 45 45 Transponder reader or z 0 0 0 Divider transponder IR activator zone 1 4 divider 0 9 in total Not managed Not managed Not managed Not managed Disconnector with key 0 1 0 1 0 1 DETECTORS lionel aontaceaneraca i 9 for each zone 1 4 1 9 for each zone 1 4 i 9 for each zone 1 4 total 36 total 36 total 36 Technical alarm interface and actuator relay 0 9 0 9 0 9 ea 0 9 for each zone 0 4 0 9 for each zone 0 4 0 9 for each zone 0 4 total 45 total 45 total 45 Burglar alarm MY HOME 1971 GENERAL RULES FOR INSTALLATION System measurement CENTRAL UNIT FOR MAX 72 SENSORS Minimum No Maximum No Minimum No Maximum No KEYS IR remote control Not managed Not managed Radio remote control 0 Transponder 0 MAX 50 in total 0 MAX 50 in total Numeric co
6. SYSTEM DISARMED Alarm event Indoor siren Outdoor siren 4072A Outdoor siren 40721 Relay actuator 3479 and Telephone communicator of Internal relay of the 3485B without internal back up with internal back up F481 1 the 3485 and 3486 central and L N NT4601 central battery battery units units 2 Tamper Rings Does not ring Does not ring Activates Forwarding of event Activates notification message Tamptest Does not ring Does not ring Does not ring Does not activate Forwarding of event Does not activate Notification Notification Notification notification message in central units with display in central units with display in central units with display or LED notification in central or LED notification in central or LED notification in central unit L N NT4601 unit L N NT4601 unit L N NT4601 Tampering disconnection Rings Does not ring Does not ring Activates Forwarding of event Activates of the central unit from the notification message system Tampering disconnection of Rings Rings Does not ring Does not activate Forwarding of event Does not activate the siren from the system notification message Anti panic Rings Does not ring Does not ring Activates Forwarding of assistance Activates request message Silence burglar alarm Does not ring Does not ring Does not ring Does not activate Forwarding of assistance Does not activate It rings if the L N NT4600 4 central unit is installed It rings if the L N NT4600 4 ce
7. Burglar alarm MY HOME 181 GENERAL FEATURES System selection criteria Today the wire burglar alarm system of structure to be made safe and the E Area to be protected can satisfy any installation needs in functions required m Alarm modes the home The criteria should thus be Four factors are to be considered m Protections indicated for a correct choice of the when choosing a system m System control components depending on the type AREA TO BE PROTECTED AVAILABLE CENTRAL UNIT WITH PSTN CENTRAL UNIT WITH PSTN FUNCTIONS e AE SEN COMMUNICATOR GSM COMMUNICATOR L N NT4600 4 TE TE haa Polyx Alarm Polyx Alarm 34858 HC HD HS4601 3485 3486 L N NT4601 Maximum number of 36 36 3 77 77 sensors KM division 4 4 4 9 8 into zones areas SYSTEM CONTROL WITH IR REMOTE CONTROL ONLY WITH WITH RADIO REMOTE CONTROL CENTRAL UNIT L N NT4600 4 AND 3486 WITH TRANSPONDER WITH NUMERIC CODE HC HD HS L N Jam a ay HC HD HS4607 L N HC HD HS4606 L N Li NT4618 iii NT4607 AM5787 NT4606 AM5786 ee Activator a Radio receiver Transponder reader Keypad connector HC HD HS4603 4 HC HD HS4607 4 348220 Radio remote L N NT4603 4 L N NT4607 4 control IR divider AM5787 4 Divider transponder 4050 3530S 3540 Remote control Badge key ring HC HD HS4608 L N NT4608 Keypad connector with display 182 MY HOME Burglar alarm PROTECTIONS AREA CONTROL F
8. WALL MOUNTED INSTALLATION ANGLE INSTALLATION IR MINI DETECTOR N4640 AND N4640B The base of the detector has a particular shape that enables wall mounted installation in 4 different modes m Wall mounted installation m Angle installation m Front angle installation m Tilted angular installation WALL MOUNTED INSTALLATION Note for other installation modes see the instruction leaflet Various sensors LAYOUT FOR MAGNETIC FLOODING DETECTOR HA DETECTOR FOR SHUTTERS CONTACTS HB L 4619 During the installation of the Fixthe device to the wall using Place the rope contact preferably magnetic contacts if a specific double sided adhesive tape or screws in the middle of the rolling shutter underground conduit is not being and plugs After completing the box and then fasten it Then fasten installed ensure appropriate surface configuration fit the key covers using the end of the rope to the rolling trunking up to the jambs of doors the spacers supplied shutter with a screw The rope can be and windows The wires of the Note If the sensor cable needs shortening cut the extended up to 3 4 m contacts will then have to be run to excess off and connect to the probe terminals NOTE The rope must be set between the window the point on the door or window and the rolling shutter Check condition of rope and where the sensor is being installed its sliding movement periodically
9. pi Activator Burglar alarm central unit i Contact interface IR sensor a Magnetic contact Indoor siren ED Outdoor siren Burglar alarm MY HOME 193 GENERAL RULES FOR INSTALLATION Example apartment burglar alarm system The power supply unit can be installed in the area of the electric distribution board The central u itnit must be installed in a protected area that can be reached easily by the user In order to facilitate arming of the system an auxiliary transponder arming device should also be included If installation of the arming device on the outside of the property is not possible or desired the activation of the volumetric sensor of the living room should be delayed On the other hand if the arming device is installed outside zone 1 will be activated without delay The system will be completed by the installation of an indoor siren in the hallway area so that the intruder will be confused by the high noise and LIST OF ITEMS REQUIRED disturbed and will be unable to hear the police force approaching An outdoor siren with optic diffuser shall also be installed outside on the balcony for easy identification from the outside of the system in alarm state When positioning the volumetric sensors it will be necessary to check the coverage area and comply with the recommendations of the following pages Using the system diagram ensure that 24 hour autonomy is guarante
10. 172 MY HOME Burglar alarm MY HOME Burglar alarm Generalfeatures 174 Generalrulesforinstallatiton 187 Configuration 203 Start up and testing 216 174 MY HOME GENERAL FEATURES Professional safety The MY HOME burglar alarm system is a safe and effective alarm system for the protection of people and their belongings capable of detecting any intrusions promptly notifying the event by means of sound and visual alarms and by sending telephone messages The system includes a central Unit that can be programmed for control and supervision of the system management and control devices volumetric sensors IR technology or dual IR MW technology for the internal protection of the house and perimeter sensors for the protection of doors and windows By integrating special devices the system can also perform safety functions such as remote assistance for old people and the protection of the house from gas or water leaks Power supply PRR RRR PROM eee ELELE IR MW sensor Burglar alarm As for all the MY HOME system the wiring of the of the burglar alarm system is based on BUS technology All the devices are therefore connected using a non polarised 2 wire cable This features allows to share information with the other MY HOME BUS functions and obtain advanced applications WIDE RANGE OF SOLUTIONS m Central u
11. By integrating a water or gas sensor with the burglar alarm system in case of such a danger event occurring the burglar alarm system activates a solenoid valve that orders the shutting off of the water or gas distribution network At the same time an indoor siren will be activated while a burglar alarm central unit communicator will forward a telephone alarm message Indoor siren optional Relay actuator REMOTE ASSISTANCE ax remote assistance REMOTE ASSISTANCE Forwarding of assistance request by calling personal numbers Old disabled or recovering people may send an assistance request using a portable remote control The signal transmitted is detected by a radio receiver connected to the burglar alarm system which activates an indoor siren and the telephone communicator of the central unit which forwards the assistance request to the set number s Radio receiver Radio control for PANIC ALARM In case of suspected noises inside the home the owner can manually activate the burglar alarm system to generate an alarm signal If the system is armed all the sirens will activate to confuse any intruders At the same time the telephone communicator of the central unit will also send a remote assistance request If the system is not armed only the indoor siren will activate if present while the communicator will forward the request for assistance PANIC ALARM Technical alarm inte
12. based on two criteria that can be customised by the user by time band and by type of area Time band Access in protected areas is only allowed at certain times For example the maid is given a key that disables the burglar alarm system each Tuesday between 9 00 o clock and 12 00 o clock Area Access inside the house is only permitted in some areas For example the gardener is given a key that only gives him access to the tool room m Managing scenarios It is possible to define up to 16 scenarios to activate with one single operation the burglar alarm system for the areas of the home that need protecting It is also possible to associate a certain scenario to each individual key Base central unit Central unit with PSTN or GSM telephone communicator Protected areas a System state Work scenario complete protection of the house Burglar alarm MY HOME 179 GENERAL FEATURES Control and protection devices ACTIVATORS Keypad connector with display These devices can be used to arm disarm the system by entering a Numeric code or using a transponder key Using the keypad connector with Transponder key reader display it is also possible to select the areas of the house that need protecting separation and to know the system status through the information shown on the display Radio remote control with built in CONTACT INTERFACES e For the connection to the bu
13. or during certain time bands 3 If the system is integrated with other MY HOME systems for example lights automation it is possible to switch all the lights of the house on if a burglar alarm system event occurs 4 Of the 10 possible automations one is activated using an auxiliary relay inside the central unit The other 9 are combined to Arming disarming Date and Time events 186 MY HOME Burglar alarm GENERAL RULES FOR INSTALLATION Project approach The project of setting up a new MY HOME BURGLAR ALARM system can be completed in two ways E Functional this is a good compromise between cost and safety The main priority is selecting which functions to include and the possibility of making the system ready for future expansion is also taken into account This solution includes for example both volumetric and perimeter protection Advantages high level of flexibility and increase in the value of the property m Economical based on an economic low cost installation It does not exclude the use of the different features offered by the system although it only calls for the use of one type of protection volumetric and does not take into account future system expansions Advantages low cost installation In order to ensure a good work setup the following elements are needed m Planimetry absolutely necessary of the living unit so that the locations where the system elements are to be installed
14. E46ADCN HC HD HS EATADCN E oos 4072L N NT4070 4072A N NT4070 Only outdoor siren w w w w Outdoor and Indoor siren ayi w w w w w Only indoor siren w w Central unit with communicator No siren w a ice my in 1 m LL Ge soon T 3486 Pm a P pmm Polyx Alarm 3485 Warning if both internal and external sirens are installed tampering with the system when disarmed will only cause the indoor siren to go off ACTIVATION OF THE ALARM DEVICES DEPENDING ON THE STATUS OF THE SYSTEM AND THE DANGER EVENT SYSTEM ARMED Alarm event Indoor siren Outdoor siren 4072A Outdoor siren 4072L Relay actuator 3479 and Telephone communicator of Internal relay of the 3485B without internal back up with internal back up F481 1 the 3485 and 3486 central and L N NT4601 central battery battery units units 2 Burglar Rings Rings Rings Activates Calls Activates Tamper Rings Rings Rings Activates Calls Activates Tamptest Rings Rings Rings Activates Calls Activates Anti panic Rings Rings Rings Activates Calls Activates Silence burglar alarm Does not ring Does not ring Does not ring Does not Calls Does not activate activate Note 1 configure the device in MOD 0 siren status repetition to enable the operation described in the table Note 2 The relay contacts can be used to connect a third party optical luminous alarm diffuser or a telephone communicator 184 MY HOME Burglar alarm
15. MY HOME Burglar alarm SYSTEM WITH CENTRAL UNIT L N NT4600 4 First of all set the central unit to ON To activate the system direct the remote control 1 towards the receiving lens 2 of the central unit at a maximum distance of 50 cm Activate the remote control by pressing the pushbutton 3 once or twice with a time interval of 5 seconds between the first and the second time until the green LED 4 lights up Activate the remote control with the pushbutton 3 thus making sure that the green LED 4 turns off Activate the remote control again with the pushbutton 3 thus making sure that the green LED 4 turns on Make sure that the red LEDs AUX 5 and 24h 6 are off NOTE if the two LEDs continue to flash it means that the selector switch at the back of the central unit has not been set to ON If the 24h LED is steadily on it means that one of the devices is producing a 24h alarm Check if the installation has been carried out properly see problems causes solutions table Make sure the green LED 7 is on In this condition the system is activated and disabled Now test the system as indicated in the next pages System test CENTRAL UNIT 3486 3485 B AND HC HD HS L N NT4601 Access the Maintenance menu and select TEST as described in the installer manual supplied with the central unit 1 When the system is disabled led o on press S and hold it down 2
16. Press the pushbutton of one of the enabled remote controls the TEST LED turns on hence you can now release the S key 3 After carrying out the verifications described in the following paragraphs Test procedure press S to end the test Make sure the TEST LED turns off Central units L N NT4600 4 J Central units L N NT4600 4 TEST PROCEDURE 1 Infrared detector check The red LED should light up when passing through the area protected by the detector 2 Contact check The red LED of the contact interface should light up when opening the windows or entrance door Warning when testing the central unit L N NT 4600 4 does not recognize the remote controls When the rolling shutter controlled by the rope sensor is raised or lowered the red LED of the interface comes on after the number of pulses set and will go off again after 4 seconds Burglar alarm MY HOME 223 START UP AND TESTING System test two line contact interfaces check The interfaces 3480 and F482 are equipped with LED indicators for properly start up the system During the startup procedure the central unit must not be powered If it is it must be in test mode 1 Connect the interface to the SCS bus and the wires of the contacts and tamper to their terminals 2 Insert the required configurators and close again using the transparent shell interface 3480 3 Clos
17. The contact wires have a reduced In order to prevent the rope from rubbing against section which will not cause any a sharp part of the rolling shutter you can glue a problems when refitting the jambs square not supplied using double sided adhesive tape Magnetic contacts Key cover L N NT4919 Burglar alarm MY HOME 199 GENERAL RULES FOR INSTALLATION Various sensors PIEZOELECTRIC WINDOW BREAKING DETECTOR 3516 3444 The detector must be applied to the glazed part to be protected using the special double sided adhesive tape supplied The glazed part must be between 1 5 and 6 mm thick the diagonal length must not exceed 3 m Fig 1 Note Clean and dry glasses before applying the detector Press hard to ensure optimum adhesion 200 MY HOME Burglar alarm RADIO MAGNETIC CONTACT 3442 The device must be installed inside the house on doors and windows including sliding ones and similar openings as shown in the figure the magnetic contact must be fixed in place using the appropriate position adjustment spacers in order to activate the alarm as soon as the movable part of the door or window starts to move away Reference tab Note To ensure correct positioning align the reference notches of the magnetic contact of the transmitter IR BARRIERS 3518 3518 50 3518 150 3519 The two
18. The opening and closing of doors and windows is detected by the burglar alarm system contact interface which reads the status of the NC contact installed on the door or window and sends the information to the temperature control system for the appropriate actions Control interface System devices The pages that follow show the main devices making up the MY HOME burglar alarm system For the full list refer to the Catalogue section BURGLAR ALARMCENTRALUNIT Available in two versions m With telephone communicator PSTN or PSTN GSM m Without telephone communicator This is the device at the heart of the burglar alarm system capable of managing up to 72 sensors in 8 areas and recognise up to 50 keys for the arming disarming of the system Using the large display the user can control the system status set advanced operating modes such as user customisation scenario management and activation of advanced functions resulting from the integration with other MY HOME systems It s also preset for the Ademco Contact ID function for forwarding telephone messages to vigilance bodies following a burglar alarm or technical alarm event Night scenario total protection of the day area and perimeter protection of the house LEGEND Perimeter protection uu Day area IR protection Night area IR protection mM Customisation of users The central unit can be programmed to allow access inside the house
19. be divided into at least 4 ZONES 2 Perimeter ZONES day night areas 2 or in villas the system should be divided into 4 ZONES or more m If the system does not include an external burglar alarm arming disarming device a time delay should fitted on the sensors protecting the main entry Otherwise the entrance area should be kept as part ZONE 1 on which a time delay can be set as standard N living room Og O On O MAN entrance o o o o O o o o Burglar alarm MX HOME 187 GENERAL RULES FOR INSTALLATION System measurement MAXIMUM REACHABLE DISTANCES The maximum number of devices availability of current based on the m The maximum length of the that can be connected to the BUS length of the cable connections between the two depends on the total absorption of During sizing ensure that the furthest away devices must not be the same and the distance between following rules are complied with more than 175 metres the point of connection and the m When two outdoor sirens are m The maximum length of the power supply installed the connection lines connections must not be more The power supply can supply up to between siren and power than 350 metres 1 2 A E46ADCN or 1 A E47ADCN supply must be separate and the the maximum number of devices will maximum length of each should therefore be determined by the sum not be more than 100 metres of the absorptions of the individual while
20. by The activation does not generate a BURGLAR ALARM al ma a a tetera ml gt e a BUS l i Burglar alarm y central unit i i Q SCS SCS i Technical alarm interface interface s l i I I I I I I I I I I I I I I I I I I I I I I Telephone line bs AE ME K NM SE E E EPEA To any other systems CONNECTIONS AND CONFIGURATIONS Technical alarm interface 3481 NOTE the auxiliary channel number 7 must also be entered at the programming stage on the burglar alarm central unit for coupling with the signalling message of the telephone communicator Renin 1 AUX device cae No of auxiliary channel Giza Anti burglary mode icine ON 3481 COM R COMC A F COM R COMC A a N C pushbutton Burglar alarm MY HOME 207 208 MY HOME CONFIGURATION Technical alarms anti panic alarm If the owner hears strange noises in the home he presses a special pushbutton to activate all the Burglar alarm system sirens only with the system armed otherwise only the indoor siren activates to confuse any intruder with the intense sound BURGLAR ALARM y A gd S6 interface To any other systems The burglar alarm central unit telephone communicator sends a request for assistance to the My Home Portal which w
21. can be defined beforehand It would also be appropriate to have a furniture plan m Definition of the protections necessary to define which system devices to include volumetric perimeter or combined protection and check that the protecting devices actually cover the appropriate areas ESSENTIAL ELEMENTS Once the above information is available the following must be agreed Selection of the protection m Volumetric protection is normally the basic protection This decision must be made taking into account various aspects with the main one being the actual location of the property For properties on the ground or 1st floor perimeter protection and or protection of the rolling shutters is recommended Perimeter protection is also recommended if external access points near balconies are also present e g rain water pipes gutters nearby balconies or terraces With perimeter protection the system can also be armed when people or animals are inside the property Example of house split into 4 zones Zone 4 bedroom odie kitchen Volumetric ZONES day night areas E In properties with several rooms Division into zones E For a better management of the sensors needed to protect the property it is recommended that the system is divided in at least 2 ZONES a perimeter and a volumetric zone up to 9 sensors per zone E n properties with more than 2 rooms the system should
22. columns must be installed one in front of the other Fig 1 in the same direction both terminal boards placed at the top side or bottom side Fig 2 the height must be as close as possible to the ground or to the lower part of the window Fig 3 with no fixed or removable obstructions that may interfere with the rays Fig 4 so that the receivers are not directly exposed to sunrays Fig 5 and are not exposed to the rays of other transmitted either directly or by reflection Each column consists of m Aluminium section bar m Top terminal base cover screw m Bottom terminal base cover screw E 4 screws 4 screw anchors for wall mounted Installation Follow the instructions on the instructions leaflet taking into account the following requirements m The cable can be inserted from the bottom inside the wall or from the outside exposed In this case Note for further information see the instruction leaflet supplied with the barriers open break the cable passage hole at the base of the unit m The terminal strips can be temporarily removed to help cable connection m For the electric connection refer to the Connection diagrams section WARNING Do not use a shielded cable when connecting the barriers to the contact interface fig 3 Burglar alarm MY HOME 201 GENERAL RULES FOR INSTALLATION Outdoor siren 1 Remove the two screws 1 and ta
23. gt ZONA E N Burglar alarm central unit L N NT 4600 4 Burglar alarm MY HOME 217 START UP AND TESTING Programming of 4050 infrared remote controls CENTRAL UNIT 3486 3485 B HC HD HS L N NT4601 Programming remote controls is facilitated by the information given by the display see the installation manual of the central unit supplied with the device FLUSH MOUNTED CENTRAL UNITS L N NT4600 4 After putting the batteries into the remote controls with the central unit in maintenance mode switch on the back in OFF position press the P pushbutton 1 using a pencil or similar object Make sure that the yellow LED PROG 2 is lit and that a short tone is emitted Place the remote control transmission lens 3 against the central unit receiving lens 4 in order to keep it perfectly aligned cover the lens in case of interferences with the infrared e g due to the direct light of lamps or spotlights 4 zone central unit Press the transmission pushbutton 5 and hold it down until the tone is emitted A tone lasting about half a second means that the programming process has been executed correctly NOTE A tone lasting about 4 seconds means that the programming process has not been executed correctly hence it will be necessary to repeat the operation When the remote control programming has been completed repeat the operation for all supplied remote controls maximum
24. indoor siren and the telephone E one or more telephone calls the sensor is received by a radio communicator of the burglar alarm M one or more sms messages receiver connected to the burglar unit which sends the assistance E one or more e mails oT m m m m e ee ee ee G Indoor Radio i i I I I I siren receiver I I I I I I I I l BUS Burglar alarm V SCS interface central unit l I I Relay i actuator l I I I I I I I I I I I I I I I I i Floodi i s iil Solenoid valve l I Il detector I I Telephone line m ww I Di e e RE RE R ii ee ee ee To any other systems CONNECTIONS AND CONFIGURATIONS Relay actuator 3479 NOTE the number 4 of the auxiliary channel is the one shown in the AUX socket of the HC HS L N NT46 18 radio receiver Configuration for manual reset solenoid valve When using a different solenoid valve connect configurator no 3 to the MOD socket bistable mode BURGLAR ALARM RNG 1 10x devi taux 5 Eo A No of auxiliary channel C MOD 4 Ein monostable contact G MOD g aa 3479 B Transformer 3479 COM T COM1 0 2 COM T COM 1 0 2 Ma Solenoid valve Burglar alarm MY HOME 209 CONFIGURATION Technical alarms flooding control CONNECTIONS AND CONFIGURATIONS Radio receive
25. of the house every Tuesday from 2 00 to 6 00 pm In order to do his job the gardener has been entrusted with a key which during the above times deactivates the burglar alarm system of the cellar All other areas of the house are still protected by the burglar alarm system armed by the owner when leaving the home for work AUTOMATION WITH CENTRAL UNIT 3485B Activation of division scenario Each time the key is used transponder radio remote control or numeric key to activate the system a specific division scenario will be activated CENTRAL UNIT FUNCTION AVAILABLE CENTRAL UNIT WITH PSTN CENTRAL UNIT WITH PSTN FUNCTIONS ALUNE FEOT PAN AN COMMUNICATOR GSM COMMUNICATOR iti fil rt i E MB L N NT4600 4 sere l TE Polyx Alarm HC HD HS4601 Polyx Alarm 3486 3485B L N NT4601 3485 Max no of keys that can be saved 1 a a au a Key constraints day zone time 2 i NO S S Max no of scenarios NO 4 16 16 Max no of NO 10 see note 4 20 see note 3 20 see note 3 automations ii TiSecurity POLYX forthe TiSecurity GSM for the prog 9 NO TiSecurity Basic for firmware update programming of parameters and programming of parameters and software firmware update firmware update NOTE 1 Keys are any control devices such as IR remote control radio remote control transponder key and numeric key 2 Each key can be set to only operate certain days of the week in certain areas
26. section GENERAL RULES FOR interfaces configured with Z 2 and Devices such as the indoor siren INSTALLATION The configuration of N 1 3 the transponder connector and the the devices depending on the area to m Zone 3 Kitchen and studio separator are only configured in be protected is the following protected by volumetric detectors the N socket corresponding to the m Zone 1 living room protected by configured with Z 3 and N 1 and number of the device within the a Magnetic contact with interface Z 3 and N 2 system configured with Z 1 and N 2 on the entrance door and a volumetric detector configured with Z 1 and Balcony eee eee ees eee le ee ee ee eee aS ieee le Bedroom 3510 Second l Contact Transponder interface activator bathroom 3510 1 2 Met Children s O C a bedroom IR sensor ee one i _ 2 F482 dk e i l 3586 Kitchen Bathroom 3510 Indoor siren l a ee ee e e 1 1 7 1 aS N 1 N1 1 2 n Transponder 3510 L4611 Living room EEE activator IR sensor OOOO ree F482 Danat inler ace J onka ivr ise _ _
27. telephone call Old or disabled people can send sends the assistance reguest to the MY This function can be activated with an assistance reguest using a HOME portal which will then warn the the burglar alarm armed or disarmed portable remote control The signal owner or any nominated individuals with any type of division sent is captured by a radio receiver by means of connected to the burglar alarm The m one or more telephone calls burglar alarm activates an indoor siren E one or more sms a e e e e aa ahaa aa we s and the telephone communicator of E one or more e mail Indoor siren optional the burglar alarm central unit which BURGLAR ALARM r BUS i P SCS SCS Burglar alarm interface centralunit Radio receiver id Telephone line i i V i CONNECTIONS AND CONFIGURATIONS Radio receiver HC HD HS L N NT4618 Indoor siren HC HD HS 4070 N NT4070 optional NOTE If the configurator is not present auxiliary channel no 9 is allocated NOTA The audible signalling of the indoor siren does not activate for technical automatically This auxiliary channel number must be indicated also at the alarms This function is performed by the natural gas detector programming stage on the burglar alarm central unit for coupling with the signalling message of the telephone communicator im ii Tong E 7 c
28. 30 NOTE in this stage it is possible to program remote controls for other systems After programming the last remote control press the S pushbutton 6 Make sure the yellow LED PROG 7 is off 218 MY HOME Burglar alarm PAIRING OF RADIO REMOTE CONTROLS 348220 1 Switch the system to maintenance mode 2 Press the Radio receiver HC HD HS L N NT4618 programming pushbutton for five seconds until the red LED comes on 3 Presstheconnection pushbutton for 5 seconds 4 If the pairing of the device has been performed correctly the red LED of the radio receiver will go off lf this does not happen repeat the procedure from step 3 If the LED flashes it means that the device memory is full 5 To save other devices in the radio receiver repeat step 2 6 Perform self learning of the system from the central unit 7 Program the remote controls on the central unit if this is of a type with display 8 Exit maintenance mode Key ring Programming of 3530S and 3540 transponders CENTRAL UNIT 3486 3485 B HC HD HS L N NT4601 programming transponders is facilitated by the information given by the display see Central unit installer manual FLUSH MOUNTED CENTRAL UNITS L N NT4600 4 The transponder badge programming operation is necessary in order for it to work as anormal infrared remote control 4050 Please keep in mind that when the transponder reader is used a
29. IMQ ALARM CERTIFICATION FOR Qd LEVEL 2 DEVICES The BTicino burglar alarm system offers solutions for each protection requirement from the minimum protection limit required in an apartment to the most stringent levels offered by professional systems Keypad connector with display Key ring badge transponder Badge transponder Transponder connector RADIO DEVICES Remote control Radio perimeter detector Radio volumetric presence detector Radio receiver BUS Keypad connector BUS MY HOME SYSTEM Automation Video door entry system Central management SCS SCS i interface To any other systems Burglar alarm MY HOME 175 GENERAL FEATURES Advanced functions the safety of the home and of people The burglar alarm system represents the basic infrastructure for alarm management but the set of applications which can be implemented can easily be expanded In fact the burglar alarm system can be used to ensure the protection of people and their belonging from dangerous events such as gas leaks flooding etc with alarm notifications also remotely through telephone messages Below are some examples WATER OR GAS LEAK ALARM Indoor siren Radio receiver Flooding detector 176 MY HOME Burglar alarm WATER OR GAS LEAK ALARM Water or gas leak detection with message forwarding and immediate shut off of the water or gas piping
30. LATION After fixing the base and performing all connections install the central unit ensuring that the cables are arranged in a way that they will not be damaged NOTE Before installing the burglar alarm central unit ensure that the sliding switch on the back is in the ON position WARNINGS FOR ALL CENTRAL UNITS Warning both in wall mounted installation and in MULTIBOX switchboards in order to ensure compliance with level 2 of CEI 79 2 standard it will be necessary to use the 3484 tamper for the protection of the GSM antenna as explained in the installation manual of the central unit PROTECTION OF PSTN CENTRAL UNITS FROM LIGHTNING It is good practice to protect the system from lightning by using surge protective devices SPD belonging to class Il For the protection of burglar alarm central units 3485 and 3486 from surges from the telephone line the use of the PLT1 device is recommended connecting the corresponding earth clamp to the earth reference of the SPD limiter installed in the apartment switchboard For further details refer to the instructions supplied with the central units or the relevant TECHNICAL SHEETS NOTE the central units are supplied with the tamper line clamps T1 circuited for the use of the local tamper T1 wall mounted installation with metal base This is compulsory to ensure that the central unit complies with level 2 of CEI 79 2 standards in terms of possible tampering tear protectio
31. UM CURRENT DELIVERED TO THE DEVICES ON THE BUS WITH POWER E if you use the E46ADCN power supply unit and the absorption is less than 150mA you will only need to install a siren 4072L if the absorption is higher than 150mA it will be necessary to install 2 sirens 4072L However the total absorption must not exceed 300mA For both cases a 24 hour duration is guaranteed E if you use the E47ADCN power supply unit you will only need to install a 7 2 Ah 12 Ah or 24 Ah battery The following chart indicates the maximum absorption required by the system according to the battery installed and to the level of autonomy required However the maximum absorption must not exceed 700 mA The maximum consumptions of the self powered devices have already been deducted from the maximum current that can be supplied by the power supply unit TABLES OF UNIT ABSORPTIONS SUPPLY E47ADCN DEVICE ABSORBED CURRENT AUTONOMY IN CASE OF 4 zone central unit 25mA TYPE OF BATTERY INSTALLED LACK OF NETWORK Central unit 3486 50 mA stand by max 120 mA 77 kh 12 Ah 24 Ah Central unit 3485 55 mA stand by max 90 mA Central unit 3485B HC HD HS L N NT4601 50 mA 24h 110 mA 190 mA 380 mA Activator 8mA Transponder reader 12 mA 15h 180 mA 300 mA 600 mA Zone divider 1 4 Zone divider 1 to 4 transponder 15 mA 8h 340 mA 560 mA 700 mA 5 8
32. according to CEI 79 22 standard use wall mounted boxes fitted with tampering and tearing protection devices to prevent units being pulled away power the system in case of power These boxes are also needed when installing Power supply E47ADCN failure from the mains The battery contact interfaces F482 or batteries with sizes not to be used with it must have the compatible with switchboards F115 8A following features 12 V 7 2 24 Ah TYPE OF SYSTEM OOo yi WITH OUTDOOR SIREN REQUIRED Power SUPY EA0ADN Battery inside the siren 3505 12 WITH OUTDOOR SIREN OPTIONAL Power supply E47ADCN Battery 12 V Siren 4072A 7 2 12 24 Ah Note the table summarises the combinations implement based on the type of system to create Burglar alarm MY HOME GENERAL RULES FOR INSTALLATION System measurement CHECK ELECTRICAL CONSUMPTIONS After checking the length of the connections it is necessary to determine the sum of the total currents absorbed by the devices installed This verification will determine whether it is necessary to equip the system with 1 or 2 outdoor sirens or the type of battery to use This is necessary in order to provide the most complex system with a minimum required autonomy of 24 hours at a temperature of 25 C in case of power failure from the mains MAXIM
33. al alarms gas CONFIGURATORS assigning them their respective leaks floods etc or alarm signalling Before configuring the devices addresses and operating modes by means of auxiliary channels remove the clear protection cover 1 The address allows you to solely The address of the device is To facilitate connection or removal of identify each device within the determined by assigning a value to the configurators use the appropriate system conversely the operating the positions tool 2 modes are the specific functions Z to specify the number of the performed by each device central assigned zone compulsory of the unit detectors sirens etc device if this belongs to the group In addition to the typical functions of detectors If the device belongs to of any burglar alarm system such as the group of connectors this position the tripping delay of a detector or the must not be configured management of a balanced contact N to specify the progressive number line it is possible through the compulsory of the device within the configuration of the operating mode above mentioned zone to enable the devices in order to Activator device Auxiliary devices So eS 0 3 4 07 OB Central unit BUS Sensors 72 devices max Burglar alarm MY HOME 203 CONFIGURATION General concepts Example of IR detector configuration First sensor belonging to z
34. ar alarm go back to the maintenance menu m check the reception level of the GSM signal E program any scenarios as needed m Program an IR remote control a transponder key or a Numeric code as shown in the following pages E enter time and date m edit the names of the zones and devices and the division scenarios WARNING If the central unit battery is exhausted the GSM module does not operate CENTRAL UNIT L N NT4600 4 Remove the support from the box if already installed and move the changeover switch 1 at the back of the device to the OFF position maintenance Power the system and check that the central unit is in maintenance mode This is confirmed by the AUX 2 and 24h 3 red LEDs flashing in succession 4 zone central unit 7 ALLARME c ZONAI g 2 CENTRAL UNIT 3485 B AND HC HD HS L N NT4601 When the central unit is switched on for the first time the Maintenance menu is shown the slide switch on the back is in OFF position To activate the central unit and make it operational E choose the language E use the central unit to start the system tutorial m move the slide switch to ON E press twice to exit the maintenance menu 1 M return to the maintenance menu E program a transponder key or a numeric code E enter time and date E customize zone device and division scenario names Central unit 3485 3485B
35. arns the owner or people indicated by him by means of E one or more telephone calls E one or more sms using the MY HOME portal e e e e mmmn Burglar alarm central unit Telephone line CONNECTIONS AND CONFIGURATIONS Technical alarm interface 3481 BURGLAR ALARM MOD wi ae eee ee ams O 3481 COM R COMC A N C pushbutton Burglar alarm E one or more e mail using the MY HOME portal This function can be activated with the burglar alarm system switched on or off and in any division condition DE we Ss Se SB SB Se Se SB Se eee ee ee ee eee SS PN tor siren optional i I I I I mmm i i BUS I I I I I I I I I Technical alarm 5 interface I I I I I I EM RCOMC A I I I lj I I N C pushbutton A Indoor siren HC HD HS 4070 N NT4070 BUS ER 1 40x cevice TTT ot kr ae HEZTEA DE no configurator ma EA D k anti panic mode p a E oj N Op JSEHH g Emr KE Technical alarms flooding control A water pipe leak or a tap left open alarm system which can activate request to the MY HOME portal which may cause serious damage if not an actuator that controls a solenoid will in turn warn the owner or any immediately detected With MY valve In addition it will also activate nominated individual by means of HOME the signal transmitted by an
36. d office Remote control transponder common to the two system 2 SYSTEM HOME V V V Office remote control transponder J y f Note carry out these operations with the two systems already activated both central units with rear selector switch in ON position Press the S pushbutton on the central unit of the second system 2 and hold it down Send an impulse using a previously enabled remote control keep it at a maximum distance of 50 cm from the central unit Make sure the yellow LED TEST 3 is on Send a second impulse Make sure the yellow LED PROG 4 is on Release the S pushbutton 2 Press the P pushbutton 5 by using a pencil or a similar object Make sure a short tone is emitted 220 MY HOME Burglar alarm Warning When programming a newly purchased remote control first of all do the programming described in chapter REMOTE CONTROL PROGRAMMING user manual NOTE make sure the system is disabled green LED 1 on 4 4 zone central unit Home remote control transponder it will be possible to program one or more remote controls able to interact with all systems J f Note all previously stored codes of the remote controls are now deleted and can no longer be recognised by the central unit Hence it will be necessary to re program all remote controls and transponders whic
37. de 0 ACTIVATORS AND DIVIDERS Keypad connector with display 0 0 Keypad connector 0 9 for each zone 0 8 total 81 0 9 for each zone 0 8 total 81 Transponder reader or W 0 0 Divider transponder pela es ea Not managed Not managed 0 9 in total with 5 8 expansion unit Disconnector with key 0 1 0 1 DETECTORS 9 for each zone 1 8 9 for each zone 1 8 IR and contact interface 1 total 72 1 total 72 Technical alarm interface and actuator rela 0 e 0 AZDA T total 72 total 72 NUMBER OF SIRENS Indoor siren Outdoor siren Minimum No Maximum No Minimum No Maximum No E46ADCN Not managed a F Not managed 2 40721 installed E47ADCN 0 3 1 0 2 4072A NOTE 1 the total number of internal outdoor sirens must not exceed 3 Example 2 indoor sirens and one outdoor siren 192 MY HOME Burglar alarm Example apartment burglar alarm system 100 m apartment on the ground floor of an apartment complex with balcony and continuous vertical protection parapet on one side The main entry consists of a door while all French windows can be considered as alternative accesses These access ways are all controlled by magnetic contacts In view of the position it is recommended that volumetric detectors are installed in all rooms thus increasing the level of safety This will also make the system easier to manage It is recommended
38. e all contacts including the Tamper 4 Power the item PROCEDURE FOR F482 E Tamper contact Line 2 LED LED indicator indicator activated activated Line 1 LED indicator activated 4 1 If the LEDs start flashing check the configuration and repeat the startup procedure If the LEDs flash quickly only 5 6 times before stopping go on to the following paragraph 4 2 If the tamper contact LED is now off go on to paragraph 4 3 if it stays on make sure that the tamper line is short circuited and then repeat the procedure from paragraph 4 4 3 If the line contact 1 line contact 2 LEDs are now off go on to 224 MY HOME Burglar alarm paragraph 4 4 if it stays on make sure that the contacts of the two lines are closed e g windows closed 4 4 Make sure the LED is on when opening the various contacts m when the contact is closed e g window closed the LED must be off mM when the contact is open e g window open the LED must be on PROCEDURE FOR 3480 Tamper contact DECIMO line 1 line 2 LED indicator activated T Ci C2 4 1 If the LEDs start flashing check the configuration and repeat the startup procedure If the LED flashes quickly only 5 6 times before stopping go on to paragraph 4 2 4 2 If the LED is now off go on to paragraph 4 3 if it stays on make sure m that the tamper line is short circuited and then
39. e system please WARNING If you are going to install a device next following the procedure described refer to the guidelines specified in the User to the central unit do not place the tamper rod in Ge Meda cp manual the new device as the system would produce a 24h ee ee ccna NN alarm The anti tampering protection is guaranteed ME Olim et tne PAYES om by the tamper rod installed on the central unit the system m Replace or add the configurators to the devices m Connect the power supply E Ensure that the central unit performs the system self learning procedure m Perform the system test ORDINARY MAINTENANCE OF THE BURGLAR ALARM SYSTEM It i h i CENTRAL UNITS L N NT4600 4 t is recommended that a test is erformerd regularly to check that E after disabling the system remove p g y the system i working correctly that the central unit from the box and the system back up batteries are set the selector 1 to OFF within y p charged as well as the condition of 30 seconds otherwise a 24h alarm signal will be produced if the nied tamper rod has been installed E switch off the system E replace or add the configurators to the devices E switch on the system m flip the selector switch 1 to ON mM install the central unit in the box E activate the system by sending one or two impulses with the remote control Burglar alarm MY HOME 225
40. ed with only one outdoor siren DESCRIPTION QUANTITY Central unit with dialling device 3486 50 mA 1 Transponder activator L4607 12mA 2 Transponder 3540 4 Power supply E46AD N 1 Jointed pass IR detector L4611 45mA 7 Contact interface 3480 5mA 2 Outdoor siren 40721 1 Indoor siren 4070 5mA 1 Outdoor siren storage battery 3505 12 1 Indoor siren storage battery 3505 6 1 Anti tamper device L4630 13 Magnetic contact i 8 Configurators 3501K 1 item to be selected based on the doors and windows characteristics 1941 MY HOME Burglar alarm a oe u oF During the installation of the system the job of the installer can be made easier by filling a system card including all the configuration information in one document as well as consumptions and positioning of the devices The card will also be useful after installation should for example the system need extending Detailed information on the compiling and use of the system card can be found in the system manuals a iy 4 T i T m 4 Installation of modular devices IN FLUSH MOUNTED BOXES The wire burglar alarm system is compatible with systems made using the AXOLUTE LIVINGLIGHT and MATIX series and therefore uses the same boxes supporting frames and cover plates When using standard flush mounted boxes depth 52 mm embedded in the mortar level with the
41. grated with each other to optimise functions and to generate new ones thus meeting new requirements In this respect the Burglar alarm system can be easily integrated with the Automation or Video door entry system using a special interface F422 Of course by using several interfaces it will be possible to create fairly complex systems through the integration of the burglar alarm system with other systems with different functions sound system temperature control etc which can COURTESY LIGHTS MANAGEMENT Interface General light control 178 MY HOME Burglar alarm therefore be managed also using a remote PC and the internet Below are some examples m By integrating the burglar alarm system to the Automation system it is possible to automatically switch on all the lights of the home following an intrusion event m Automatic disabling of the heating system By integrating the burglar alarm system with the heating system it is possible to set a particularly useful function which can bring in important energy savings by avoiding unwanted dispersion of heat to the outside for example when changing the air inside AUTOMATIC DISABLING OF THE HEATING SYSTEM Magnetic contact o Opening of Ny window Interface a the house In practice when the doors or windows of a room are opened the heating system of the temperature control zone of that room is automatically turned off
42. h will need to act on this system by following the descriptions in chapter REMOTE CONTROL PROGRAMMING user manual Direct the remote control previously wait for the beep sound After completing the programming programmed on the first system From now on the remote control operations press the S pushbutton towards a 1 to 4 zone divider or code for the first system will also be 1 and make sure the yellow LED connector of the second system recognised by the second system PROG 2 is off Press the remote control pushbutton When the remote control as if it were a normal enabling programming has been completed process repeat the operation for all remote If a transponder is used move it controls requiring this function 30 towards the transponder reader and altogether Activator Divider zone 1 to 4 max 50 cm SN C max 50 cm N amp R a O O gt 66 j 4 zone central unit K z i 2 transponder 3 4 o bticino l Burglar alarm MY HOME 221 START UP AND TESTING System activation SYSTEM WITH CENTRAL UNIT 3486 3485 B HC HD HS L N NT4601 After completing the operation described in the chapter Putting into operation of the system the central unit becomes operational Perform a system test as described below ON OFF slide switch impianto E on off LU tHe a b a b Central unit 3486 rear view 222
43. hing on the lights because of an alarm GEN OFF An interesting application is the risk of immediate identification device devices to dialogue possibility of automatically switching will induce the thief to leave This Obviously the lights can also be on all the lights or a group of them function is obtained by connecting switched on and off by means inside the home for a preset time the automation device and burglar of the local control device in the following an intrusion This adds an alarm systems with an interface automation system element of confusion to the sound which allows the burglar alarm signal emitted by the siren and the central unit and the automation BURGLAR ALARM pop i BUS SCS SCS i DG interface ON General control i i OOOO of the lights 5000 i AUTOMATION e i BUS CONNECTIONS AND CONFIGURATIONS SCS SCS interface F422 General control of the lights H L4652 2 BURGLAR ALARM BUS o sss interface GEN General configurator V DE No configuration ON control upper key 074 and OFF control lower key X MAZA3 No DE Configuration X DZA n o 4 interfacing mode C MOD burglar alarm AUTOMATION BUS 214 MY HOME Burglar alarm Advanced applications remote assistance reguest with
44. ixed sensitivity Variable sensitivity PERIMETER CONTROL Sensors Barriers Detectors Swivel IR distance 6 m L N NT4611B AM5791B Fixed IR distance 3 9m HC HD HS4610 L N NT4610 AM5790 3510 FLUSH mounted magnetic detector ee eel 3511 Visibly magnetic detector a 3516 Window breaking detectors A 3514 Cable detector for shutters ai Wall mounting IR distance 6 m N4640B al w Wall mountingIR Wall mounting distance 3 IR distance 4 9 m 12 m N4640 3440 ge 3513 Magnetic detector for metal main doors 3512 Magnetic detector for swing doors 3444 Window breaking radio detectors i j 3445 Cable radio detector for rolling shutters T Dual technology distance 10 m HC HD HS4613 L N NT4613 Swivel IR distance 3 9 m HC HD HS4611 L N NT4611 AM5791 a 3510M Brass FLUSH mounted magnetic detector A Brass FLUSH mounted magnetic detector 3510PB 3518 3518 50 3518 150 3519 IR barriers for windows 3442 Radio opening detector Burglar alarm MY HOME 183 GENERAL FEATURES System selection criteria ALARM MODES OPTION1 Back up battery in the outdoor siren Option2 Back up battery in the switchboard POWER SUPPLY OUTDOOR SIREN INDOOR SIREN POWER SUPPLY OUTDOOR SIREN INDOOR SIREN m e e EN ee bazi S m a
45. ke off the external cover 2 2 Remove the four screws 1 and pull out the internal protection cover 2 3 By using the drilling template 1 position the hole 2 near the wire outlet pipe and scribe the 5 holes NOTE use a 6 mm bit for drilling the holes 202 MY HOME Burglar alarm 4 Insert the screw plastic plugs into the holes and partly tighten the top screws 1 and the tamper screw 2 pa a end LA en cone Ba Wha Dee pee SP A AN 5 Adjust the tamper screw by using the notch 1 on the drilling template as shown in the picture Warning If the installation or the adjustment of the tamper screw is carried out incorrectly the system will not work PON BDO 4 Ose 26st N OMI vt GELS GEG TEMPLATE 7 Put the battery 1 or 12V 12Ah battery into the special housing without connecting the Faston terminals Connect the electronic card as shown in the instruction leaflet supplied with the siren 1ej10710700 010 8 D LL Guten DADO Arg 6 Attach the siren to the two top screws 1 Tighten the two bottom screws 2 Tighten the four screws completely ee il Voge Corb CONFIGURATION bl c na General concepts Configuring the devices of the perform special functions such as the CONNECTION REMOVAL OF burglar alarm system means management of technic
46. n For installations inside MULTIBOX boxes ensure the connection of a NC circuit breaker to the T1 clamps for Wall mounted installation of 3485 or 3485B central units This same method is also used for the installation of the 3486 central unit Installation of the 3486 central unit inside a MULTIBOX switchboard Local tamper T1 Tamper line see note the tamper function For further information see the central unit installation manual Burglar alarm MY HOME 197 GENERAL RULES FOR INSTALLATION IR detectors ADJUSTABLE IR DETECTOR HC HS L N NT4611 In addition to the indications shown for the installation of modular devices also take into account that before installing the swivel IR sensor the adjustment fixing screw 1 at the back of the detector must be loosened in order to allow the detector to turn Note the screw will be tightened after the System test and protected zone check thus setting the central unit in maintenance mode 198 MY HOME Burglar alarm RADIO IR DETECTOR 3440 Two installation modes are possible m Wall mounted installation m Angle installation Before permanently securing the object ensure that the radio communication with the H HD HS L N NT4618 receiver is working correctly
47. n their configuration If the there is any information connected to intrusion events the devices activate local signallings sirens or remote signallings telephone dialling devices if on the other hand the information relates to technical alarms based on the set operating parameters the devices activate to generate alarm or prealarm signals or to reinstate safety within the controlled environment Some typical examples are the application for the automatic shutting off of the gas piping following the detection of natural gas leaks described in this guide and the operation of the burglar alarm central unit in ADEMCO protocol mode forwarding of telephone calls to vigilance bodies following a burglar alarm or a technical alarm event In this case when configuring the 3486 central unit the use of the auxiliary channel with the type of technical alarm that generates the call is already set as shown in the following table COMBINED AUXILIARY CHANNEL Flooding Anti panico General technical alarms Fire Remote assistance Configuration example The following drawing shows E Zone 2 house perimeter m Zone 4 bedrooms hallway the example of the configuration protected by magnetic contacts bathroom protected by volumetric of the burglar alarm system of on the French windows and the detectors configured with Z 4 and the apartment described in the windows connected to three N 1 4
48. nit with integrated PSTN or GSM communicator managing up to 72 sensors in 8 areas E Transponder connectors radio wave connectors infrared and Numeric code connectors m Wired or radio devices m Technical alarm management m Ademco Contact ID communication protocol management Outdoor siren x I 1 101 1111 IR sensor RADIO EXPANSION By integrating the radio interface with the BUS system it is possible to expand the burglar alarm system with radio detection and control devices A range of optional functions also become available m Technical alarms using a specific sensor it is possible to perform flood control of the room m Remote assistance to assure peace of mind and prompt assistance for people in difficulties m Radio control it is also possible to integrate aradio remote control for radio arming and disarming Central unit with PSTN or GSM communicator BUS a Basic contact Magnetic interface contacts INTEGRATION WITH OTHER MY HOME SYSTEMS Using a special interface the burglar alarm system can be easily integrated with other MY HOME systems to obtain the following m Advanced applications resulting from the synergy among the individual systems for example automatic switch on of the lights following a burglar alarm event m Local central management or remote central management via the Internet using the MY HOME WEB portal of the system
49. ntral unit is installed It rings if the L N NT4600 4 central unit is installed Note 1 configure the device in MOD 0 siren status repetition to enable the operation described in the table Note 2 The relay contacts can be used to connect a third party optical luminous alarm diffuser or a telephone communicator request message Burglar alarm MY HOME 185 GENERAL FEATURES System selection criteria CENTRAL UNIT FUNCTION In addition to the criteria explained in the previous pages the selection of the central unit can be made taking into account the possible available functions such as m KEYS ONLY OPERATING DURING CERTAIN TIME BANDS Enabling for the cleaning staff In order to be able to do her job the maid has been given a key for the disarming of the burglar alarm system across the whole house but only between 9 00 o clock and 12 00 o clock on normal working days During all other times and holidays the key does not operate m AUTOMATION WITH CENTRAL UNIT 3486 OR 3485 Switching on of all home lights If the burglar alarm system is integrated with the automation system it can be set in such a way that if burglar alarm event occurs some or all the lights of the house will come on inducing the burglar to leave m KEYS ONLY OPERATING IN CERTAIN AREAS Enabling access for the gardener The cellar is used to store gardening tools and is made accessible by the owner
50. one 2 with pulse count function enabled CONFIGURATOR POSITION VALUE i 2 No 1 MOD 1 AUX none Example of contact interface configuration Fourth sensor of zone 3 with balanced protection of the contact line CONFIGURATOR POSITION VALUE Z1 3 N1 4 MOD1 Balance resistance 10 KQ 5 1 4W 204 MY HOME Burglar alarm AUXILIARY CHANNELS In addition to the typical functions the devices of the My Home Burglar alarm system can also perform a range of functions independent from the status of the burglar alarm system itself armed or disarmed This is possible thanks to a particular communication channel of the burglar alarm and automation bus called auxiliary channel used by some devices such as the auxiliary channel interface or the radio receiver for the transmission of information such as health emergency robbery emergency etc In order to better clarify this concept the burglar alarm system may be compared to a 3 lane road with the first one used for the transit of police cars information connected to intrusions or burglary while the second is for service cars information connected with the operation of the system and the third lane is for emergency services information connected with auxiliary alarms or events Auxiliary devices are capable of handling the sets of information from TYPE OF TECHNICAL ALARM Gas leak Freezer the three lanes and act accordingly based o
51. oor siren L E EMEN IAT yon h mii technical alarm deactivation EEE a 1 receiver device EX No of auxiliary channel ZX BN DE BURGLAR ALARM Burglar alarm MY HOME 215 START UP AND TESTING Start up Note this operation must be carried out after configuring the system In order to startup the system all devices must be connected and installed properly into their supports CENTRAL UNIT 3486 When the central unit is switched on for the first time the Maintenance menu is shown the slide switch on the back is in OFF position To activate the central unit and make it operational proceed as follows m choose the language E use the central unit to start the tutorial m move the slide switch to ON E press CLEAR twice to exit the maintenance menu E select Communication GSM Management menu and enter the PIN code mM go to the main screen by holding down CLEAR switch off the central unit m disconnect the battery E insert the SIM card E connect the battery again and switch the central unit back on again wait for the battery to fully charge icon OFF m make sure there is a line connection E wait about one minute during this time the Error Or INS icons might be displayed After one minute both icons should disappear if they do not disappear check the PIN code or check if the SIM card is disabled by inserting it in a mobile phone 2164 MY HOME Burgl
52. plaster tile or in any case where the maximum depth from the bottom of the box to the finished wall is less than 60 mm cut the tamper rod 1 at the first reference notch insert it in the appropriate housing rotate it 90 and then remove it completely 500 503E 504E 5061 However if the maximum depth from the bottom of the box to the finished wall plane is 60 mm insert the appropriate rod protection device tamper in its housing 1 rotate it 90 and remove it completely 500 503E 504E 5061 IN WALL MOUNTED BOXES If the flush mounted box is different This series of boxes already has a from the BTicino standard box with supporting frame for the devices and reduced depth less than 52 mm the LIVINGLIGHT boxes have white proceed as follows completely cover plate When installing modular remove the tamper rod devices inside wall mounted boxes or corner boxes proceed as follows m Remove the cap A from the bottom of the devices by rotating it 90 m Do not fit the clear protection cover B Fit the devices inside the wall mounted or corner boxes In this case the anti tamper Place the tip to the bottom of the box protection C is already on the box without pushing too hard and cut the Pay attention to ensure that the rod level with the box Insert the rod tamper rod of the box fits perfectly 1 protection device tamper in the in the preset hole at the back of the app
53. r HC HD HS L N NT4618 NOTE The number of the auxiliary channel must also be indicated during the programming of the burglar alarm central unit for coupling to the signalling message of the telephone communicator as well as in the configuration of the relay actuator that controls the electrovalve The coupling between the flood detector and the radio receiver must be completed before installing the detector itself To save the detection device see the Configuration section Kiza Ist detector device in zone 9 iz mia No of auxiliary channel BURGLAR ALARM Indoor siren HC HD HS 4070 N NT4070 In alternative to the radio flood detector contact interface 3480 together with sensor 3482 can also eki ALARM based e iin in BUS L W e k EE EE ELEM koof n N2 O MOD2 pi ara DECIMO SCS D of LL ISS E NC Alarm reset Tamper line o amp vwool Po ee Eis 1 Indoor siren Z1 1 9 Interface address Interface address De no configurator N1 1 9 Z2 No configurator N2 wy a No configurator MOD1 Ea NO contact technical alarm MOD2 Eo Wes No of auxiliary channel see note above 210 MY HOME Burglar alarm Technical alarms gas leak alarm with burglar alarm system
54. ral unit installer manual In systems with FLUSH mounted central units L N NT4600 4 a new programming process is required to delete previously stored transponders or to add new ones Follow the procedure described in section REMOTE CONTROL PROGRAMMING of course during this procedure the badge will have to be moved near the transponder reader instead of the central unit This procedure will delete all stored transponders partial deletion is not possible SYSTEM ENABLED 0 5 sec OFF SYSTEM DISABLED 0 5 sec Fixed green INCORRECT ACTIVATION 4 sec Flashing green ALARM OCCURRED Fixed red DEACTIVATION AFTER ALARM OCCURRED sec det 0 5 sec Fixed orange allows you to check the zone in which the alarm occurred IMPORTANT the central unit can save up to 30 system arming disarming devices If a transponder is used as a remote control only 29 devices can be saved This is because an IR remote control 4050 must always be present Burglar alarm MY HOME 219 START UP AND TESTING Programming a remote control or a transponder for several systems CENTRAL UNIT 3486 3485 B AND HC HD HS L N NT4601 Programming is facilitated by the information given by the display see Central unit installer manual 1 SYSTEM OFFICE FLUSH MOUNTED CENTRAL UNITS L N NT4600 4 If you have two or more burglar alarm systems with a flush mounted central unit for example home an
55. reaker and This function is only valid with 3485 to lightning electric disturbance or reinstates power supply in full safety and 3486 central units fitted with system fault If however the fault remains due to telephone communicator The main condition for this useful an insulation defect or line overload function is that the SALVAVITA the burglar alarm system will send STOP amp GO device is connected to an SMS telephone message or a the burglar alarm system through pre recorded message to notify the an interface for the detection of the user of the problem The telephone status of the earth leakage circuit message can also be forwarded to hte Ea bhems Sc S jem ART 3485 BURGLAR Central unit ee i STOP amp GO BUS Technical alarm Control interface nas MN dl 1 a device No of auxiliary channel technical alarm with normally closed contact ART F80CMD coN E s lectmdde 3 Cauk NOTA auxiliary channel number 3 must notification by operating also be indicated in the burglar alarm central the selector with a flat head ee unit programming to link it to the telephone screwdriver communicator signalling message Auxiliary channels between 1 and 9 can be selected Burglar alarm MY HOME 213 CONFIGURATION Advanced applications switc
56. repeat the procedure from paragraph 4 m the enclosure of the interface is well closed and then repeat the procedure from paragraph 4 after switching the power off m the contacts of the two lines are closed e g windows closed and then repeat the procedure from paragraph 4 2 4 3 Make sure the LED is on when opening the various contacts m when the contact is closed e g window closed the LED must be off mM when the contact is open e g window open the LED must be on COMPLETION OF THE TEST STAGE m 3486 3485 B and HC HD HS L N NT4601 central units Exit the Maintenance menu following the procedure described in the installation manual supplied with the central unit m L N NT4600 4 central units Once the checks have been completed press pushbutton 1 check that the TEST LED 2 has gone off and move the ON OFF selector 3 to the OFF position Remove the swivel IR detectors from the box and tighten the screw locking the adjustments 4 zone central unit E ALLARME 2 C ZONA1 7 Configuration or system modifications Maintenance If it is necessary to modify the i 4 tral unit configuration of the system after een starting it up follow the procedure C ALLARME H O ZONA1 9 below after disabling the system CENTRAL UNITS 3486 3485 B AND HC HD HS L N NT4601 E Go to the Maintenance menu NOTE for normal operation of th
57. rface N C pushbutton STOP amp GO TELEPHONE SIGNALLING OF TRIPPING OF THE GENERAL CIRCUIT BREAKER By connecting SALVAVITA STOP amp GO to the burglar alarm system using a special interface it is possible to receive a telephone message in case of tripping of the circuit breaker due to storm electric disturbance or system fault STOP amp GO Technical alarm interface ANTI BURGLARY ALARM In case of danger it is possible to activate the burglar alarm system for sending a remote assistance request through the central unit communicator The activation does not generate a sound alarm thus allowing the police force to surprise the burglar who is not aware that the call has been made ANTI BURGLARY ALARM The SALVAVITA STOP amp GO device automatically closes the tripped circuit breaker reinstating the power supply in fully safe conditions However if the fault remains due to an insulation defect or line overload Control interface Indoor siren optional Technical alarm interface N C pushbutton the burglar alarm system will no longer try to reinstate the power supply but will forward a message Stop amp Go circuit breaker Burglar alarm MY HOME 177 GENERAL FEATURES Advanced functions integration with other MY HOME functions By sharing the same means of information transmission BUS pair the MY HOME applications can be easily inte
58. rglar alarm system of normally closed NC or normally open NO magnetic contacts for the protection of doors and windows DIN contact interface IR SENSOR IR barriers For the protection of the areas of the house Cee Available in two versions interface m With IR sensor m With IR sensor and MW microwave sensor IR MW sensor For the protection of doors and windows IR barriers are also available in lengths between 0 5 and 2 metres Note For the full list of all the available devices refer to the Catalogue section 180 MY HOME Burglar alarm Devices for radio expansion and technical alarms IRSENSOR AND RADIO Window breaking radio detectors MAGNETIC CONTACT Battery powered these devices can be used to protect rooms where no A BUS wiring is present VN M Radio IR sensor im gt WIRE RADIO INTERFACE It allows integration with the wired Wire radio interface burglar alarm system of radio technology devices such as the radio remote control in the previous page and the devices listed below DEVICES FOR TECHNICAL ALARMS This family includes devices such as m The radio control to send an assistance request m The radio sensor to detect the e presence of water a for Remote assistance m The Auxiliary channel interface for integrating gas and water sensors Radio water sensor with the burglar alarm system m The Basic module contact interface
59. ropriate housing rotate 90 and device remove completely Warning BTicino wall mounted boxes are suitable for installation of devices with level 1 performance For level 2 performance CEI 79 2 standard use the box 502PA for angle installation o gt OQ J lt 52mm Fix the devices to the flush mounted boxes Warning the use of the tamper rod for the protection of FLUSH MOUNTED BOXES devices with BTicino supports is a necessary requirement to assure level 2 protection in accordance with CEI 79 2 standard For the selection of the flush mounted boxes see the General Installation Catalogue Check that there is no damage at the bottom of the box in the tamper rod working area Take the necessary measures to solve any problems Burglar alarm MY HOME 195 GENERAL RULES FOR INSTALLATION Modular power supplies All the power supplies are sold with Tamper device against the opening of the switchboard Depending on the power supply being used two types of installations are possible 196 MY HOME Burglar alarm Installation of power supply E47ADCN E47 12 These devices are installed inside the switchboard F115 8A If required install the back up battery ies in the appropriate housing of the 7 2 Ah enclosure F115 8B For batteries of higher capacity check the compatibility with the F115 8B enclosure When the N C contact is also being used for addi
60. s a activator it will almost always be installed in places different from the one in which the central unit is located Therefore it is recommended to temporarily connect it near the central unit The initial programming which is carried out when installing the Transponder reader shall be carried out with the central unit in MAINTENANCE mode selector switch located on the back in OFF position 4 zone central unit ees 24h wN O amp O TEST 1 2 o Cy o Cc o S proc 3 4 CD O OC OC O bip IMPIANTO 7 mn oa z Procedure 1 With central unit in maintenance mode press the P key and check if the yellow LED PROG lights up 2 Re program the IR remote controls first see chapter REMOTE CONTROL PROGRAMMING 3 Now move the badges towards the transponder reader figure at bottom left 4 Make sure that two short tones are emitted the first is emitted from the transponder reader the second is emitted from the central unit 5 Repeat points 3 and4 forall available badges 6 Whenyouhavefinishedprogramming the last badge press the S pushbutton on the central unit the yellow PROG LED turns off and move the back selector switch to ON dwg A LUMINOUS AND AUDIBLE INDICATORS DELETING OR ADDINGA TRANSPONDER When using central units 3486 3485 B and HC HD HS L N NT4601 the deletion of transponders is facilitated by the information given by the display see Cent
61. that volumetric systems are always installed as the intruder may be able to break Arrangement of the components and wiring layout Living room through the physical barriers rolling shutters window glass without actually opening the door or window In this case the magnetic detector on the opening would in fact be unable to generate the alarm This type of setup would also give the user the possibility to customise the system to meet personal needs This gives clear advantages ona management point of view For example E perimeter protection can be used during the night E volumetric sensors can be armed whilst leaving perimeter sensors disarmed during short absences all SS If n n o No WS a Pap my Ss Ss SS Ss Bedroom aj o Ola Ns A Kitchen Children bedroom 7 Ei aj J Vek jj NE tf 1 y Balcony To ensure this flexibility the various sensors should be grouped appropriately In this case the system can be divided as follows E magnetic contact and volumetric detector for the living room zone 1 mM magnetic contacts for doors and windows zone 2 m daytime area volumetric detectors kitchen studio zone 3 E sleeping area volumetric detector bedrooms hallways service bathroom zone 4 SYMBOL LEGEND
62. the sum of the two should devices to be installed not be more than 175 metres In calculating the absorptions it will also be necessary to consider the MAXIMUM BUS CABLE LENGTHS A B 175 m MAX A 100 m max m A C 175 m MAX B 100m max A B C 350m MAX O COMO LI CICICICICI CI CI CI CI CI EI Ci Ci ti LCL LL 1 OT NE ty OJ eee Note During this check do not consider the connection between NC normally closed contacts and the corresponding interface module 188 MY HOME Burglar alarm SYSTEMS WITH AND WITHOUT OUTDOOR SIREN Traditional burglar alarm systems which require an outdoor siren as it is equipped with the back up battery of the whole system can sometimes cause inconvenience to neighbours in case of an alarm especially in condominium flats BTicino gives you the opportunity to avoid this drawback by using a specific power supply unit instead of the power supply E46ADCN This power supply unit can be used for connecting a back up battery not supplied It is easily available and necessary to The power supply unit and the battery are installed in wall mounted enclosures F115 8A and F115 8B which guarantee protection against tampering attempts thanks to special self protection systems The outdoor siren is now considered optional However if you want to install it use siren 4072A Warning in order to install the devices and assure level 2 protection
63. tional tampering protection of the battery connect the contact on the F115 8B enclosure to a tamper line of the system Warning for batteries of sizes not compatible with F115 8B enclosures use the required DIN switchboard in the general BTicino catalogue In order to assure level 2 performance in accordance with CEI 79 2 standard it will be necessary to use wall mounted switchboards with opening and tear protection If the power supply is installed in switchboards without door ensure that it is not subjected to water sprays Battery Installation of power supply E46ADCN These devices are installed inside standard flush mounted or wall mounted switchboards Warning In order to assure level 2 performance in accordance with CEI 79 2 standard it will be necessary to use flush mounted switchboards with opening protection or wall mounted switchboards with opening and tear protection If the power supply is installed in switchboards without door ensure that it is not subjected to water sprays Fnsure that the vents are not obstructed A two pole thermal magnetic circuit breaker with contact separation of at least 3 mm must be used positioned near the power supply The function of the circuit breaker is to disconnect and protect the power supply NOTE For more information and for the wiring requirements refer to the instructions supplied with the power supplies Central unit with display WALL MOUNTED INSTAL
64. zone expander 10 mA In this case the system complies with level 2 of the CEI 79 2 standard Disconnector with key 5mA Keypad connector with display 28mA Keypad connector 5 5mA Fixed sensitivity IR detector Passive IR detector 45mA e a SR ERE ee I Passive IR articulated detector MAXIMUM CURRENT DELIVERED TO 12 V DEVICES WITH POWER SUPPLY E47 12 ce This power supply is used for example in IR barriers Dual technology detector 2mA 35mA IR barriers 50 mA AUTONOMY IN CASE OF TYPE OF BATTERY INSTALLED ic Mele SmA LACK OF NETWORK Contact interface 12 V 5 mA 72 Ah 12 Ah 24 Ah Contact interface 2 DIN mod 6mA Interface 3480 5 m 24h 300 mA 500 mA VA Relay actuator 20 mA 15h 480 mA 300 mA 16A Technical alarm interface 6 m Radio receiver 15 mA 8h 900 mA 15A 2A Indoor siren 8 mA In this case the system complies with level 1 of the CEI 79 2 standard Outdoor siren 4072A 5 mA Note in order to ensure level 2 performances according to CEI 79 2 standard in case of lack of Interface F422 2 m network power supply use batteries capable of ensuring system autonomy for at least 24 hours Note Plus the absorption of the detector connected to it Consider 35mA for the first detector installed 5 mA for all the others 1901 MY HOME Burglar alarm Each system can be made up of a minimum and maximum number of devices as shown in the following tables CENTRAL UNIT FOR MAX 36 SENSORS