Home
User Manual - BTE Corporation
Contents
1. View Event Details To view any event details window proceed as follows e Right click on the event of interest e Execute the Open command The window shown below displays all available event information Note that when the event is an acknowledged alarm see Alarms section below date and time of alarm acknowledgment is also shown as well as user name of the user who acknowledged the alarm The Source button displays event source When the button is pressed the Viewer displays the window when available associated with subsystem which generated the event Filter Events To filter events click on any of the available filters on the left side of Event Viewer Your system administrator can set up appropriate filters for viewing event log subsets Alternatively a search on any of the available event log columns can be made for a keyword or value of interest See the User Interface section on how to search for a keyword BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 16 of 25 Alarms Alarms are events whose veatLevel property is tagged as ALARM You can search for alarms by clicking on Alarms filter To acknowledge one alarm e Right click on the alarm e Execute Acknowledge Alarm command SM records the date and time of alarm acknowledgment as well as the user name of the user who acknowledged the alarm This information can be viewed in Event Details window To acknowl
2. meters electric water gas etc switches etc BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 19 of 25 Remote Stations Remote Station Group Manager Status Name Manager Status PowerPlant Enabled OK PowerPlant Enabled OK SESubstation Enabled OK SESubstation Enabled OK Name Manager Running Status LastPollDT NextPollDT PowerPlant Enabled Yes OK 2013 09 28 11 06 00 2013 09 28 11 07 00 PowerPlantM Enabled Yes OK 2013 09 28 11 06 00 2013 09 28 11 07 00 SESubstation Enabled Yes OK 2013 09 28 11 06 00 2013 09 28 11 07 00 Name Manager Running Status LastExecutionDT NextExecutionDT PowerPlant Enabled Yes OK 2013 09 28 11 06 20 2013 09 28 11 07 20 PowerPlantM Enabled Yes OK 0001 01 01 00 00 00 NONE SESubstation Enabled Yes OK 0001 01 01 00 00 00 NONE Name Name Manager Status MRTO NRC InpuiManager All Brownville Enabled OK 670 SESubstation PowerPlant EastFeeder Enabled OK 670 SESubstation SESubstation Feeder3 Enabled OK 639 PowerPlant Feeder4Recloser Enabled OK 546 Feeders Enabled OK 686 Feeder6Recloser Enabled OK 546 GEN1 Enabled OK 546 GEN2 Enabled OK 530 GEN4 Enabled OK 468 GENS Enabled OK 561 GEN6 Enabled OK 546 GEN7 Enabled OK 468 Howe Enabled OK 670 JohnsonFeeder Enabled OK 655 v Window RS_DNP_30 GEN6 was opened OK PowerPlant PowerPlant PowerPlant PowerPlant PowerPlant PowerPlant PowerPlant PowerPlant PowerPlant SESubstation O O O O O O O O O O O OOO
3. 1 004 User Manual Page 15 of 25 latest 1000 or so depending on default filter settings event log records and alarms associated with that object Event Viewer can also be opened independently as a stand alone program In that case all events are displayed By this it is meant that the latest 1000 or so depending on default filter settings records are displayed unfiltered An abbreviated version of Event Viewer is also built into the bottom of most every window There about 100 latest events associated with monitored subsystem are displayed Startup and Shutdown To start up the integrated window Event Viewer display click on the Events button at the bottom of the window just to the left of the status line To start the full integrated Event Viewer right click on the object of interest and execute Events command The full Events Viewer starts displaying events associated with that system object To start the full Event Viewer independently click on the Event Viewer icon on Windows desktop or execute the Event Viewer command in Windows Start menu The full Events Viewer starts displaying unfiltered events associated with all system objects To shut down Event Viewer simply click on the X button at the top right of Event Viewer window To close the integrated Event Viewer at the bottom of any window click on the Events button in that window The Events button is a toggle it opens and closes the integrated Events Viewer
4. alarm sounds are permanently enabled on host machine e Disable Alarm Audio alarm sounds are permanently disabled on host machine e Persistent Alarm Audio makes alarm audio on host machine persistent until silenced with Silence Alarm s command e Non Persistent Alarm Audio makes alarm audio on host machine non persistent one time only at the time of new alarm Database Editor SmartMaster properties parameters are recorded and maintained in SQL server tables Database Editor is used for display and editing of those parameter values The values can also be printed out In addition this program is used to define which columns are shown in the various tabular displays The program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Configuration Brownville Parameter Name Type Manager RTS PTS ResponselO MRTO NRA RSGroup Tags InputManager OutputManager LSER Address CIOPP CIIPP CI2PP CI3PP CHOCode Ctll Code LocalControlReporting DeviceTroubleReporting DeviceRestoriReportina Value Brownville GenericDNP30 Enabled No 5000 686 2 SESubstation SESubstation SESubstation LogAndAlarm 5 1 0 0 0 Hex81 Hex4 LogAndAlarm LogAndAlarm Log FunctionNotSupportedReporting LogAndAlarm e Parameter Diagnostics value was modi
5. field e g controls analog outputs In SmartMaster the short name for inputs and outputs is O points Monitor I O Point Values To monitor I O point values e Open Main Viewer e Open RemoteStations service window e Right click on to window title e Execute YO Points command BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 21 of 25 To view subsets of I O points either click on one of the filters on the left side of I O points window or open one of remote stations windows as described in a latter section Your system administrator can set up appropriate filters for viewing I O point subsets Control an Output To issue a manual control command e Right click on control output e Select Operate command e Execute desired control operation To manually operate a group of control outputs e Select outputs to be operated by clicking on outputs while holding down the Ctrl key e Select Operate command e Execute desired control operation Some devices require a Select command to be issued before Operate command can be executed In those cases proceed as follows e Right click on control output e Execute Select command e Right click on the same control output again e Select Operate command e Execute desired control operation View I O Point Data To view data associated with I O point e Open I O points window as described above e Right click on I O point of interest
6. in one of the window displays point the mouse to that object Commands followed by three periods are not executed immediately they followed by at least one more prompt or a confirmation dialog There are two kinds of commands e Commands executed by UI After command execution the Viewer confirms command execution in the status line of the window where command was submitted e Commands executed by the server In this case the Viewer confirms submission of command to the server in the status line of the window from which command was submitted An example of command executed by UI is the Open command which simply opens another window on the local machine An example of command executed by the server is an Operate command which operates a remote switch The command is first submitted to the server which in turn sends an appropriate message via appropriate communications channel Navigation To open a window associated with specific object point to that object and execute the Open command A new window associated with that object opens Configuration BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 9 of 25 To reconfigure an object point to that object and execute Configuration command Database Editor opens with that object parameters loaded Please consult the Database Editor section for details on how to reconfigure system objects Self Documentation Commands are se
7. 5 1 004 User Manual Page 23 of 25 e Open SystemUsers service window e Right click on system user of interest e Execute Open command I O points associated with selected user are listed in the YO Points display SCADA SCADA service is responsible for scheduling and execution of user authored programs and management display of one line diagram displays Name Manager Running Status Compiled LastExecutionDT NextExecutionDT RestoreAllLoads Enabled Yes OK Yes 0001 01 01 00 00 00 NONE Name Title Manager Status Substations Substations Disabled OK Brownville Brownville Disabled OK Sheridan Sheridan Disabled OK v Events Window Service Scada DisplayMonitor was opened List of programs To view the list of programs available for execution e Start the Main Viewer e Right click on the SCADA service window e Execute the Open command Available user authored programs are listed in the display titled Programs Program Execution Your administrator can create programs and schedule programs for periodic execution To manually execute a user authored program proceed as follows e Open the SCADA service window e Right click on the program of interest e Run the Execute Program command e Confirm program execution BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 24 of 25 Indications of successful program execution are two fold e Execution confirmation in the event log e D
8. 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 3 of 25 Introduction SmartMaster SM documentation is divided into three parts 1 User Manual 2 Administrator Manual 3 Technical Notes Audience User Manual should be read by all SM users It is intended for users who use SM for monitoring and control of their distribution system such as electric power grid a gas distribution system a water distribution system etc but are not involved in changing SM configuration Administrator Manual is intended for users who are also able to set up and reconfigure SM so it better reflects the monitored distribution system Technical Notes are intended for BTE engineering staff they document SM internal workings and specifications SmartMaster Overview SmartMaster consists of several parts e Services running on customer server e User interface UI programs the Viewers running on workstation computers e Credentials configuration program User Id e Deployment programs e BTE server resident components Services Services are SM components running on customer server machine They are responsible for e Al database management Communications with devices integrated into monitored distribution system Running of all application algorithms e Definition and enforcement of security Event logging including alarms Dispatching of important event notices to designated users e Execution and dispatc
9. O PowerPlant Monitor Remote Stations To monitor remote stations devices monitored in the field proceed as follows e Open Main Viewer BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 20 of 25 e Open RemoteStations service window To view a selected subset of remote stations click on one of the filters to the left of Remote Stations display Your system administrator can set up appropriate filters for viewing remote station subsets Monitor Remote Station To monitor a remote station e Open Main Viewer e Open RemoteStations service window e Right click onto remote station of interest e Execute Open command The window not only displays remote station details but also I O points associated with that station Poll Remote Station To issue a manual poll of remote station proceed as follows e Open Main Viewer e Open RemoteStations service window e Right click onto remote station of interest e Execute Po command Alternatively in the window associated with remote station of interest proceed as follows e Right click on the title part of the window e Execute Poll command Inputs and Outputs In SmartMaster inputs are subsystems which manage data associated with corresponding data sources in the field e g voltage readings temperature readings flow rates etc and outputs are subsystems which manage data with corresponding data consumers in the
10. SmartMaster 12015 USER MANUAL BTE CORPORATION SmartMasterTM 2015 1 004 User Manual Page 1 of 25 Contents CO OntentE EDS DEEG NA aa 1 Io AE RE RE EE OE RR EE OE EE RE EE 3 PRM LL TNC OAR EE EE OO OD OO OE E E 3 SmartMaster M Overview ui ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee aan 3 ee die EE EE RE EE EE N 3 VIEW RE EE EE EE A 4 RE e EEN D Deployment e EE D BTE Resident ComponentS ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 6 EIEN ei el rrur Ee OE EE EO EO RO Ee NO RE 6 Startup a 6 Window Sade did N N EE OE ON GE eer Ero 6 Command EE EEN 8 Navigation N N ntet oette rto nre Eo EES EEO EEPE EESE EEOEEEP ESEESE EES EEEE EEEE EESE EESE EEEE eenn 8 E EE E E E N E EA A E E AAAA A N 8 S lf Do umeantHO se ee SEER SR ER EE ER GR EE EE RE Pe EE Ee ee 9 SSAC Del EE RE ee NE OE N EE OE OE NN 9 PERDE SEE EAN 9 Main EE e OE OE OE EE OO EE N EE 9 Startup and Shutdown ee ee ee ee a ee ee ee ee ee ee ee ee ee 9 Default Open Windows ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 10 COTA ANS OO ea EE EE eae ase tnes ee Sta TEE 10 COnM SUA EOI AA EA Ee 10 AS SG OE EE GE DE A ee esa Eero EES EERE Eg 10 oi AARON N IE EE N OE N N Ee 10 Noel is de AR ON ON A aA Nai 11 Alarm AtdiG EE 11 Patabase e eener EE EE EE EE EE EA N N OE OE Val Startup and ShutdOWA ees tddi 13 Edit Parameter Valie ees ees ee dese see Bee ee sed dan ee ese ed daa eie Sesde dia ees 13 Column Visibility in Tabular Displays es es ee ee ee
11. above section Click on parameter of interest Enter new parameter value e Repeat for other parameters Click on the Save Exit button to save changes When the Save Exit button is pressed Database Editor sends appropriate commands one for each parameter value change to the server Every command is processed on the server individually every parameter value change is saved and recorded in the event log Column Visibility in Tabular Displays Database Editor can be used to select which columns are shown in tabular displays To select visible columns proceed as follows Open the window of interest Right Click into the tabular display of interest Select Configuration command Click the Visibility button in Database Editor the list of column names in selected display is shown Toggle columns that are to be visible to Yes others to No Click on the Save Exit button 7 Restart Main Viewer PEA Do Self Documentation In addition to general self documentation mentioned in the User Interface section Database Editor additionally self documents every parameter listed in the display When the mouse cursor is placed over specific parameter documentation about that parameter is displayed In most cases that is all documentation that is needed to understand the meaning of the parameter In exceptional cases where parameters are more involved additional documentation is provided in administrator manual BTE CORPORATION 631 673 8339 ht
12. ase Editor is used for display and editing of database values The values can also be printed out In addition this program is used to define which columns are shown in the various tabular displays The program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program Event Viewer is used for real time display and management of system events and alarms It provides tools for searching sorting printing and exporting of system events as well as alarm acknowledgement commands The program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program Data Viewer is used for real time data displays It shows data in tabular and graphical forms in real time and provides tools for sorting filtering exporting and analysis of stored data as well as real time data trending The program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program Report Manager is a program for management of reports Users can start Report Builder and create or modify reports In addition existing reports can be stored on report server in various user created folders Folders can be assigned appropriate security Report execution can be manually initiated or scheduled for periodic execution Subscriptions can be made so reports can be delivered via electronic mail in one of the various popular formats html PDF Excel etc Th
13. atabase modifications and system behavior dictated by the program For example if a program is to restore all load points turn on power to all customers previously disconnected by the system event log program execution confirmation is followed by control codes going out to all devices on customer sites restoring their power followed by database updates documenting above actions List of One Line Diagram Displays To view the list of one line diagram displays proceed as follows e Start the Main Viewer e Right click on the SCADA service window e Execute the Open command Available diagrams are listed under Displays Open a One Line Diagram To open a one line diagram e Open the SCADA service window e Right click on the display of interest e Execute the Open command One Line Diagram Commands One line diagrams are user authored They consist of various display elements Each display element DE is a part of the whole picture representing part of the monitored distribution system Some of DEs are mapped on to I O points so diagrams can be interactive DEs mapped onto I O points provide additional functionality e Their color changes when flown over by the mouse e Their appearance may change based on the state of associated I O point e They expose commands which can be executed directly from one line diagram display For example if a DE is mapped to a control output DE exposes commands which enable the user to manually oper
14. ate that control output To operate commands exposed by a display element proceed as follows e Open one line diagram display of interest e Right click on the DE of interest e Execute command of interest Available commands depend on the type of associated I O point All commands are self documented as described in the User Interface section BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 25 of 25 Report Manager Report manager is a web based program for accessing and management of reports It can be started by executing Main Viewer Reports command as described above It can also be opened via a web browser by going to http lt server name gt Reports_SmartMaster Above lt server name gt is the name of your server Only nternet Explorer and Firefox browsers can be used at this time To execute and display a report e Click on the folder where report is stored e Double click on the report of interest BTE CORPORATION 631 673 8339 http www btecentral com
15. cing activities Viewers Viewers are user interface UD programs used by users to interact with SM They can run on the server or any of the workstations They provide e Real time screens for viewing of the various sections of database such as system snapshots event log views data views etc e Commands to SM to execute various tasks such as manually operate a remote switch or back up the database e Screens for database configuration changes which modify SM behavior such as change polling period or modify analog input threshold values e Screens for writing of user authored programs e Screens for graphical distribution system representation one line diagrams e Screens for report definition execution and dispatching options BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 5 of 25 Devices Services The following programs are available Main Viewer this is the main UI program which integrates all other UI components It opens up the top screen which shows customer name as well as the list of services running on the server Users can open all other windows from here All windows are updated in real time Each window can be sized and positioned as desired When re opened all previously opened windows return the same size and location as when they were closed In addition each window can be set to automatically open when the Main Viewer is opened Datab
16. e program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program in a web browser Report Builder is a program for building of reports Users can define data sources report layout data rendering and displays of various forms charts plots graphs gauges etc Users can save reports on any disk drive or on report server When saved on report server reports can be executed and dispatched automatically see Report Manager above This program can be started via Report Manager BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 6 of 25 User Id User Id is a program which identifies a user associated with specific Windows Account to SM This program is run one time only so SM knows who is subsequently running the Viewers when logged on to a specific Windows user account and assigns them appropriate security privileges Deployment Programs There are two deployment programs Services Update is responsible for updates of all service components on the server This program is installed on the server only and is manually executed when services need to be updated to the latest available version Viewers Update is responsible for updates of all Viewers This program is installed on the server and all workstations running the Viewers It is manually executed when Viewers need to be updated to the latest available version BTE Residen
17. e Execute Data command Data Viewer opens displaying I O point data in tabular and graphical forms Please consult the Data Viewer section for options and commands available in that program SystemUsers This service is responsible for management of system user lists user related security definitions and assignment of important system event user notifications BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 22 of 25 System Users Name Manager Running Status UserNotifications LogUserNotifications SystemUsers Enabled Yes OK Disabled Yes UserName Role JDoe SMAdministrators Manager Status LastName FirstName Login Login2 Enabled OK Doe John JDoe NONE v Window SystemUser 1 Doe was opened OK Display System Users List To view the list of system users proceed as follows e Open Main Viewer e Open SystemUsers service window The users are listed in System Users display Display Server Logins Server logins are credentials for signing on to SQL server Each SmartMaster M user must have at least one login To view the list of available logins proceed as follows e Open Main Viewer e Open SystemUsers service window The logins are shown in the Server Logins display View System User I O Points To view the list of I O points associated with a particular system user e Open Main Viewer BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 201
18. ed on the workstation hosting the Main Viewer Each workstation can have its own settings independent of others Commands Main Viewer top window hosts a handful of specific commands which affect the system globally Configuration Like in most other windows this command starts Database Editor and loads parameters associated with related object in this case SmartMaster service One important parameters is DatabaseBackup which enables system administrators to set up automatic system database backup schedule Backup Database This command initiates immediate system database backup cycle Holidays This command opens the Holidays window which lists holidays that matter to functioning of the system Some regularly scheduled functions may not want to be executed on certain days of the year System administrators can enter those days into the database BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 11 of 25 Reports This command opens the Report Manager see section below Alarm Audio This is a collection of commands for management of sounds associated with alarms Execution of these commands is local to the host workstation running the Viewer For example when alarm audio is silenced it is turned off on the local workstation only The following commands are available e Silence Alarm s silences alarm sounds until next new alarm transpires e Enable Alarm Audio
19. edge multiple alarms e Select multiple alarms e Execute Acknowledge Alarms command Alternatively one can acknowledge multiple alarms as follows e Optionally Select Alarms filter e Right click on the Alarms filter e Execute Acknowledge Alarms command Data Viewer Data Viewer is used for real time data displays It shows data in tabular and graphical forms in real time and provides tools for sorting filtering exporting and analysis of stored data as well as real time data trending The program is fully integrated into the Main Viewer but can also be opened independently as a stand alone program BTE CORPORATION 631 673 8339 http www btecentral com SmartMaster 2015 1 004 User Manual Page 17 of 25 Data Brownville RealPower Brownville_RealPower 2013 09 27 00 00 00 000 2013 09 27 10 00 00 010 Name Analysis All NONE Daily NONE GAS NONE LastMonth NONE LastMonthHourlyAverages HourlyAverages LastWeek NONE LastYear NONE LatestMinutes NONE MONTHLY NONE ThisMonth NONE ThisWeek NONE ThisYear NONE HourlyAverages Yesterday NONE YesterdayHourlyAverages HourlyAverages ValveDT 2013 09 27 2013 09 27 2013 09 27 09 2013 09 27 2013 09 27 04 00 2013 09 27 09 41 Time HH MM Reading 1440 entries with filter Today Base Number 343 AND ValueDT BETWEEN 2013 09 27T00 00 00 0000000 AND 2013 09 28T00 00 00 0000000 Startup and Shutdown To start the integrated Data Viewer pr
20. eduled database backup cycle for 2013 09 25 00 00 00 Request for manual operation of remote station Brownville control Loc Request for manual poll of remote station Brownville received from user PowerPlant 2013 09 24 01 12 36 288 2013 09 24 08 32 09 679 Remote station Brownville will be polled in 5 seconds Control point Brownville SCADARecloserControl switched to LOCKOUT state by PowerPlant 9240 2013 09 24 08 22 14 702 Request for manual poll of remote station Brownville received from user PowerPlant 9243 2013 09 24 10 44 14 368 Remote station STATIONPOWER1 resumed responding S Data point filter manager LastMonth parameter Analysis was modified SE EE Ee from HourlyAverages to NONE by PowerPlant Data point filter manager Daily parameter StariDT was modified from 2013 08 20 12 00 00 000 to 2013 08 10 00 00 00 000 by PowerPlant gt Data point filter manager Daily parameter EndDT wos modified from AI IS 2013 08 21 15 04 00 000 to 2013 08 11 00 04 00 000 by PowerPlant 2013 09 24 08 32 11 114 9245 2013 09 24 16 20 04 908 ne Reading 1000 entries with filter ThisWeek EntryDT BETWEEN 2013 09 23T00 00 00 0000000 AND 2013 09 30T00 00 00 0000000 The program is fully integrated into the Main Viewer When a user requests to view events associated with a specific system object Main Viewer launches Event Viewer and displays the BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015
21. ee ee ee ee ee ee ee ee 13 EE TEE EE 13 Slater AA OO EE EE EE EE EE OE DE 14 DRR UR EE EE EE OE EE N EE N 14 EE EE Gert E EE ER ER Ee Ede 15 view Event Wetailot cece ie EE EE GE S ee Pe ED ro ee ie 15 Filter Events tonto eg 15 A a 16 Data EEN 16 Startup and ShutdOWNn rn nn nr nono ee error e ee ee ee ee ee ee ee 17 Filter Data mata 17 ebe EI e HEET 17 Delete Data e EE N N EE enese re s Dons egs 18 Remote SLA LION Secs EE EE EER EE iio OE Ee Ee ee ee 18 Monitor Remote Stations EE EE 19 Monitor Remote Stations EERS Es tee Se Ge Se E Ge Se ee Se Ge Se Pe SEE EE EE 20 Koll Remote Statio N sers ee EE E GE ER RE GE ER ee 20 BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 2 of 25 putand o re ee ee ee ee ed EO PA Se Oe AA ee EE 20 Monitor 1 0 Point Valles ve n bee ES GE DE DE EE GE EE EE BE RR Ee 20 Controlan OUPUL EE EE SE ER EE EE 21 View I O Point Data 21 NADIA 21 Da A EV ESEG IE EE ED EE DE DE DE OE DE DE DE DE RE 22 Display Server Logins ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 22 View System User E e 22 SADA 23 LISTO DO SEAS ES EE EE EE EE EE ee EE ee 23 Program EELER OR de ee dee 23 List of One Line Diagram Displays es ee ee ee ee ee ee ee ee ee ee ee ee 24 Open a One Line Diagram ee ee ee ee ee ee ee ee ee ee ee ee ee ee 24 On e hine Diagram Command S EE EER SEDES ESE Gee Ee ee ee bee RE 24 R port Managef EE N ER ER Re ENEE Ee 25 BTE CORPORATION 631 673
22. ewer Main Viewer is a gateway to all available user interface windows and displays It integrates database editing event viewing and data viewing into one program Startup and Shutdown When the Main Viewer is started the top window shown in the Window Structure section above opens as well as any default windows see below Windows can be individually closed as needed When the top window is closed all windows opened via the Main Viewer are closed automatically BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 10 of 25 You cannot shut down SmartMaster with any of the Viewers your system administrator can do that using Windows Service Control Manager SCM Default Open Windows Users can define which windows open by default when the Main Viewer is opened They can also set size and location of those windows This is accomplished as follows e Open the Main Viewer e Open another window which is to open by default e Size and position that window e Execute Window at Startup gt Open at Startup command on that window e Close the Main Viewer top window To remove a window from the default open windows list proceed as follows e Open the Main Viewer Default windows also open e Select the window of interest e Execute Window at Startup gt Do NOT Open at Startup command on that window e Close the Main Viewer top window Above settings are particular to and stor
23. fied from Enabled to Disabled The program is fully integrated into the Main Viewer When a user requests to view parameters associated with a specific system object Main Viewer launches Database Editor and displays those parameters Database Editor can also be opened independently as a stand alone program When started independently the program lists the tables available for editing After the user selects one of those tables Database Editor displays parameters in that table BTE CORPORATION 631 673 8339 http www btecentral com Page 12 of 25 SmartMasterTM 2015 1 004 User Manual Page 13 of 25 Startup and Shutdown To start the integrated Database Editor right click on the system of interest and execute Configuration command The full Database Editor starts displaying parameters associated with that object To start the full Database Editor independently click on the Database Editor icon on Windows desktop or execute the Database Editor command in Windows Start menu The full Database Editor starts by displaying database tables available for editing To close Database Editor and save changes of parameter values click on the Save Exit button To close Database Editor without saving changes simply click on the X button at the top right of the Database Editor window or click on the Cancel button in that window Edit Parameter Values To edit parameter values proceed as follows e Open Database Editor see
24. hing of reports to designated recipients The following services are available in this version of the software e SmartMaster this is the top level service responsible for startup and shutdown of all other services and for performing other system wide functions such as periodic system backup management of globally used tables etc e Communications responsible for management of all communications channels including those for communications with remote devices those for inter service communications and those for communications with user interface clients BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 4 of 25 e RemoteStations responsible for management of devices integrated into monitored distribution system such as substation IEDs voltage regulators reclosers etc RTUs meters electric water gas etc switches etc e Systemlsers responsible for management of system user lists user related security definitions and assignment of important system event user notifications e SCADA responsible for scheduling and execution of user authored algorithms and management of one line diagrams e LoadManagement responsible for scheduling and execution of load management and demand response related algorithms e CapacitorControl responsible for management of capacitor banks on the power grid e MeterReading responsible for automated meter reading and invoi
25. lf documented When the mouse cursor is placed over a command documentation about that command is displayed In most cases that is all documentation that is needed to understand the meaning of the command In exceptional cases where commands are more involved additional documentation is provided in this manual In tabular displays table columns object properties or parameters are also self documented When the mouse cursor is placed over a specific column documentation about that column is displayed In most cases that is all documentation that is needed to understand the meaning of the parameter In exceptional cases where parameters are more involved additional documentation is provided in this manual Same documentation is provided in Database Editor where parameters are self documented When the mouse cursor is placed over a specific parameter documentation about that parameter is displayed Searching One can search for keywords or values in tabular displays To search proceed as follows e Open the desired window e Right click in the tabular display of interest e Select column to be searched e Enter keyword or value to look for The system responds by displaying only lines which contain sought for keyword or value To clear the search press Esc key original full list is displayed once again Printing Contents of most displays can be printed by right clicking on the display and selecting Print command Main Vi
26. nection Below the display s are Events button Status Line and Status Indicator BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 8 of 25 Status Indicator is displayed only in windows associated with services It shows OK or ALARM S depending on whether or not there are alarms pending associated with that service Status Line in above example showing Window Service Scada was opened shows user interface events It is the only part of the window where the UI reports what goes locally not on the server The Events button shows or hides the abbreviated Event Viewer display below The Event Viewer display at the bottom of the window when shown lists events pertaining to the monitored subsystem only The list is abbreviated to 100 latest events Event Viewer display functionality is the same as that of the full Even Viewer Please consult Event Viewer sections for details Commands Commands are issued with the mouse The technique to issue commands is straight forward and consistent across all UI windows To issue a command targeting specific object subsystem proceed as follows e Point to the object and press the right mouse button e Select the desired command from the context menu and click the left mouse button To issue a command targeting the object whose window is already open point the mouse to that window title To issue a command targeting an object displayed
27. oceed as follows e Open I O points window as described in the Inputs and Outputs section e Right click on I O point of interest e Execute Data command Data Viewer opens displaying I O point data in tabular and graphical forms To start the Data Viewer independently click on the Data Viewer icon on Windows desktop or execute the Data Viewer command in Windows Start menu Data Viewer starts displaying the list of available I O points Once I O point is selected I O point data is displayed To shut down Data Viewer simply click on the X button at the top right of Data Viewer window Filter Data To filter data click on any of the available filters on the left side of Data Viewer Your system administrator can set up appropriate filters for viewing data subsets Export Data To export data to a Microsoft Excel file proceed as follows e Open Data Viewer BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual e Right click on to the display entitled Values e Execute Export to Excel command e Specify file name and location Delete Data Point To delete a data point e Open Data Viewer e Right click on to the display entitled Values e Execute the Delete Data Point command Remote Stations Page 18 of 25 RemoteStations service is responsible for management of devices integrated into monitored distribution system such as substation IEDs voltage regulators reclosers etc RTUs
28. s cancelled LOG Service SMService stopped LOG Service SMService starting up LOG Service SMService started LOG Database backup manager scheduled database backup cycle for 2013 09 19 00 00 00 LOG Each window is associated with one of system objects subsystems being monitored In above case the window is associated with SmartMaster service the top service as described in previous section The top part of the window shows SmartMaster Joe monitored subsystem name in above example name of the company running SmartMaster and the clock System licensing information is displayed when mouse cursor glides over the SM logo Below the top part of the window are white regions called displays They are sub windows into subsystem being monitored updated in real time There can be one or several displays depending on the open window In above example there is one display showing a list of services installed on the server and their status The title of each display is shown at the top of the display in black letters In above example the title shows the version of services running on the server Services 2013 0 036 as well as version of the database running on the server dbv 1 Displays can show tabular displays graphical displays selected web page graphs etc all updated in real time no matter where the user interface is with respect to the server same room or thousands of miles away on a machine with internet con
29. t Components These are components running on BTE server responsible for licensing version deployment and communications They also host central one line diagram display element library User Interface Listed below are properties common to all user interface windows Startup and Shutdown Viewers are started and terminated like any other Windows program To start up a program simply double click onto the appropriate icon on Windows desktop or select appropriate menu item in the Start section of Windows Since SM security is fully integrated with Windows Domain SQL server no additional action is required Viewers or individual windows are closed like any other windows simply click on the X button on top right of the window Window Structure Viewer windows have a well defined structure Shown below is the top window which opens when Main Viewer is started BTE CORPORATION 631 673 8339 http www btecentral com SmartMasterTM 2015 1 004 User Manual Page 7 of 25 BTE Corporation Huntington NY Services 2013 0 036 dbv 1 Name Manager Running Status Communications Enabled Yes oK Installations Enabled Yes OK LoadManagement Disabled No OK RemoteStations Enabled Yes OK Scada Enabled Yes OK SystemUsers Disabled No OK Events Window Service Seada was opened OK EventLevel Entry LOG Service SMService initiating shutdown procedure Reason SCM Stop request Previously scheduled database backup cycle wa
30. tp www btecentral com SmartMasterTM 2015 1 004 User Manual Page 14 of 25 Printing Contents loaded into Database Editor can be printed in two ways By clicking on the Print button entire contents are printed out By clicking on the Print Scrn button only the portion shown in display is printed Event Viewer SmartMaster V records all system events and alarms into a single database table Event Viewer is SM component for real time display and management of those records It provides tools for searching sorting printing and exporting of system events as well as alarm acknowledgement commands Events All Services Name Number EntryDT Eventlevel Entry AckAlarms Y TS Request for manual operation of remote station Brownville control Alarms PS Ma GEMIK ee Brownville_ SCADARecloserControl received from user PowerPlant AllEvents 2013 09 23 16 21 54 776 LOG Remote station Brownville will be polled in 5 seconds Control point Brownville_ SCADARecloserControl switched to RESET LastMonth T EI asiMon 2013 09 23 16 21 56 226 LOG dala by Powedtion LastWeek LastYeor 2013 09 23 16 21 59 783 LatestMinutes ThisMonth ThisWeek 2013 09 23 16 32 16 437 Remote station WestLoop resumed responding ThisYear 2013 09 24 01 00 00 014 Database backup manager initiated database backup cycle Today Database backup mana d o 19 ger reporting database backup cycle Yesterday aoe ee ae completed sucessfully Databose backup manager sch