GelAnalyzer 2010 User`s manual Contents
Contents
1. Aa 8 1 Manual baseline tool E By using the manual baseline tool you can define the background of an individual baseline profile by adding and moving control points of the baseline To activate the tool press the manual baseline button in the main window s toolbar In the profile window the cursor turns to crosshair and with one left click you can define a vertical baseline After this when the cursor is crosshair you may add new control points with a single left click or grab the existing control points and move them Existing control points except the first and the last one can be deleted by right clicking on them The baseline modification only works when the without background mode is turned off 8 2 Rolling ball background subtraction AR Rolling ball is an automatic way to define the background of a profile lt can be background imagined as when a ball is rolled on the inverted profile Where the ball touches the subtraction profile will be the points of the background The radius of the ball can be set when using the tool Also you can decide whether you want to use on all lanes or just on the selected one AR 8 3 Valley to valley background subtraction Valley to Valley to valley is a rather simple background approximation method It can only be valley used when there are bands on the lane It works such a way that it connects the end background bio and start points of the successive bands H 9 Rf calibra
2. anatase A O oben N miss This tutorial will lead you through the process of analyzing gel images with GelAnalyzer The elements of the GUI and the functions of the program will be described as they occur in the course of a gel image evaluation 1 Starting GelAnalyzer GelAnalyzer does not need to be installed All you need to do is to extract the downloaded archive to an arbitrary directory To run the program you need the Java Runtime Environment JRE to be installed on your system JRE version 1 6 or later is required In Microsoft Windows systems you may start the program by running GelAnalyzer exe In other systems you need to run the GelAnalyzer jar file For further Information refer to the Java documentation on your system 2 The main window When GelAnalyzer has successfully started you will see the main window The main window consists of a menu bar a tool bar and a large empty space that acts as an inner desktop The inner desktop will hold the other windows that only appear when you have either created a new analysis or opened an existing one The elements of the menu bar are the following e File menu commands to create new analysis open an existing one save the current and copy or export contents of inner windows and results e Analysis menu here you will find the MW standard manager described in details later an option to switch the image type described in the next section and a command to bring up the an
3. entirely analogous to quantity calibration MW calibration and calibration evaluation is based on the known Rf value MW value pairs of the calibration bands mon Assigning MW values to bands selecting curve fit is the same as in quantity calibration thus these parts won t be discussed again Besides assigning MW values to bands GelAnalyzer provides tools to manage MW standards as unit You may load previously saved standards to lanes and save the MW values on a lane s bands as a standard Also GelAnalyzer has an inbuilt MW standard manager where you can manually create new standards add or delete bps and export it to text files or import standards from external text files GelAnalyzer uses its own file _7 format to store the MW standards All the standards are stored in the standards mws file To manage the standards open the standard manager from the analysis menu in the main window The usage of the standard manager is rather straightforward and it won t be discussed thoroughly here 12 The analysis info window The analysis info shows the bands in the analysis along with all their important values In the window s Show menu you may select a display restrict show bands on all lanes show bands on the selected lane show the mw or calibration bands only The MW and quantity values of the calibration bands are shown in bold font type 13 Saving and opening analysis exporting results Save You may save the
4. GelAnalyzer 2010 User s manual Contents A A ee S ZINC main WITT OW aan BCA evar MEW aN alY SIS wccecsp ie sac otra eo cates Pet ian nena acta saiep ucpeateietnasatcadaesta as uineauap expects slew lo ehdinssacsaunacer ies A TINE NAS CNW INOW sai ratio Lan ES NOC ds De DELTECH lanesattomaticalVi ii ds AB A AAA o A mes a E E DO GINEW 1AM manually Sasi cs hacen id e SA IVIGGIFY EXISTING lanes ii ia G6 MINE PORE WINDOW to alii EEN BaANOS NOC CORO uo E A O O TA AUtOMatiG pand DETECTO aer ici 7 2 ROG MEW band Manually Sc5sccsasansseeaussideisipasaenccao neces a a a OEN a ia OEE 7 3 Delete bands on the selected lane ooooocccnnnnnccconnnonnnnnnnnnononanonnnnnnnnonnnnnrnnnnnnnnonnnnnrnnnnnnnnnnonnnos 7A MOodity existing bands ON Selected le ii 3 BacKerouna s btractio n MOOG ii ad Ss EMa ntal Daseline LOO Muir di 3 2 Rolline Dallbackerounas ubico riera bicios 8 3 Valley to valley background subtraction ccccoocccnconoccnnonanonnnnanonnnnnacnnnonanonnnnononnnonaronnonanonnnnnncnnnnnas RECIO IIO MNO dEi srren E T E EE OEA TO Quantity cabra On MONE e E A A EAA 11 Molecular Weight MW Calibration MoOde ooccccnccnoncnnnnnononoconononanocnnnnonanocnnnnonanoconnnnnanonnnncnnanonos 12 The an Aly SIS INTO NWI IOWA Aa 13 Saving and opening analysis exporting resultS ooonccnnonnccnnonnocnnnnonocnnonanonnnnnncnnnonarnnnonanonononaronnnnos NE LAN SUAS Circ bseeisyeddeciench incor anaana Gud bolnees a aust ncs a a
5. a x b x c e Linear log In y a x b e Log y a e c You may select the used curve from the analysis settings dialog To open the analysis settings dialog open the Analysis menu in the main window and click Settings To fit a linear or linear log curve you need at least 2 calibration bands For quadratic and log curves at least 3 calibration bands are necessary The fitted curve will be displayed in the calibration curves window The cal curves window has two tabs one for the MW calibration curve and the other one for the quantity calibration If there are enough calibration bands for the selected curve type the curve will be fitted and all bands in the analysis will be evaluated immediately The evaluation is entirely automatic i e at the moment you perform any modification that involves the changing of the number or value of the calibration bands the calibration curve will be refitted and all bands will be evaluated Any modification of the calibration bands raw volumes including the modification of the background subtraction will result in the recalculation of the calibration curves and the evaluation of all bands in the analysis The cal curves window s panels display the fitted curve along with markers for the calibration bands The fitted curve s equation is also shown here along with the R coefficient of determination value of the fit sf 11 Molecular Weight MW Calibration mode MW MW calibration is
6. alter the position of the band boundaries the peak sign position will be automatically reset to the maximal intensity position The peak sign s position is important since it marks the band s Rf value thus it is the basis of the MW calculation 8 Background subtraction mode In background subtraction mode you may define the background of the individual AA ae profiles manually or use built in methods to automatically define the background on MORE a single lane or on all lanes at the same time The defined background will be subtracted from the volumes of the bands This way the uneven illumination of the image can be compensated thus a more precise quantity calibration and evaluation can be achieved The previously mentioned without background button in the profile window s toolbar can be used to switch between the display modes when the background is shown separately and when the background is subtracted from the profile The usage of the display modes does not affect the calculations Currently there are three possibilities in GelAnalyzer to define background If you would like to define the background of an individual lane s profile use the manual baseline tool For automatic background definition you may use the valley to valley and rolling ball methods Every change in the profiles background results in the recalculation of the quantity calibration if there is valid quantity calibration in the analysis
7. alysis settings dialog e Windows menu commands to move the inner windows front in the inner desktop and to restore the default inner window arrangement e Help menu currently only contains the command to bring up the info about GelAnalyzer The elements of the toolbar except the new analysis and open analysis buttons are inactive when there is no analysis loaded The first three buttons serve the purpose of creation loading and saving analysis The other six buttons serve for switching between program modes The program modes will be discussed in details later on When you switch to a program mode the second row of the toolbar will show the buttons corresponding to the operations in that mode 3 Create a new analysis ma To create a new analysis use the command in the File menu or the button in the toolbar After this a file open dialog will be shown where you need to select the gel image Only PNG JPEG and GIF image formats are supported If you wish to analyze an image in a different format there are many free programs available that can make the conversion for you When you have selected the gel image a dialog will be shown where you need to select the image type Choose the light on dark option when the spots on the image are lighter than the background and the dark on light option in the opposite case If you need to change image type later on you may do this by using the option in the Analysis menu However changing i
8. can be grabbed and moved with the mouse Control points except the first and the last one can be deleted by right clicking on them Rf curves except the start and end curves can be deleted by right clicking on them on a position where there is no control point present The start and end curves can only be deleted by deleting the entire rf calibration Note that the MW calibration and evaluation is based on the Rf value of the bands The band s Rf value is calculated from the peak sign s position 10 Quantity calibration mode a Quantity measurements of the individual bands is based on fitting a curve to known calibration raw volume calibrated volume data pairs The fitted curve is used to calculate the mode quantity volume of unknown bands The bands whose quantity value is known are called calibration bands To assign quantity value to known bands left click on the circle that marks the band in the image window A text field will appear where you can type in the value Press ENTER to finalize the value or ESC to cancel the process When a value has been assigned to a band its marking circle will turn into orange color and the value will appear next to it You may modify the value by left clicking on the band mark again To delete a band from the quantity calibration right click on the marking circle GelAnalyer currently contains four curve types for the fitting process These are e Linear y a x b e Quadratic y
9. entire analysis in GelAnalyzer s own format To save the current analysis analysis choose the Save analysis or Save analysis as options from the file menu or Open l l TE analysis saved in the file You also have the possibility to export contents and or copy the the corresponding button from the main window s toolbar The analysis will be saved in a gap file In contrast with the previous version of GelAnalyzer the image will be also content of the internal windows You may export and copy the current content of the image window the profile window and the cal curve panels The content of the analysis info window can be copied to the system clipboard and pasted to any spreadsheet program for further usage 14 Language The language elements are loaded from the selected txt file in the language directory The structure of the file is the following e Lines that start with the character are comments and won t be used e Empty lines are also ignored e The structure of other lines is key value where key identifies the language element and value is the assigned text value You may create new language files to adapt GelAnalyzer to your own language If an error occurs during the loading
10. he graph area vertically To zoom on the horizontal axis you may use the options in the profile window s toolbar s zoom box These options are e Fix zoom values 100 200 and 300 the length of the profile is scaled with the chosen value Use the horizontal scroll bar to scroll the profile if it is larger than the graph s width e Fit profile mode the length of the profile is fit to the graph s width Scrolling is not possible in this case e Manual zoom with this tool you can select the part of the profile to be displayed When you select it from the options the cursor turns into crosshair and you can select the part of the profile with the mouse by pressing left mouse button and dragging the mouse Right mouse click before area selection cancels the manual zoom Maximally 1000 magnification is allowed this way For a subsequent selection choose the option from the zoom tool again and repeat the process i The window s toolbar has another button Without background in order to display Wana the profile by subtracting the defined background from the intensity values Defining background backgrounds and background subtraction will be explained later on AA 7 Bands mode Bands In bands mode you can detect bands automatically on the selected lane or on all lanes at mode once You may manipulate the bands on the selected lane namely modify their boundaries delete bands and manually add new ones The band modifying o
11. mage type will cause the deletion of all bands on every lane and the analysis results will be lost 4 The image window When you ve successfully created a new analysis the inner windows will appear The upper left corner that displays the gel image is called the Image window Operations in Lanes mode Rf calibration mode Quantity calibration mode and MW calibration mode take place in this window The window has a toolbar with a zoom scale selection option IN 5 Lanes mode anes mode In lanes mode you may detect add modify and delete lanes All these operations take place in the image window To switch to lanes mode press the lanes mode button in the main window s toolbar The default submode in lanes mode is lane selection You may select lanes by clicking on them in the image window The selected lane s profile will be plotted in the profile window and the info about the selected lane s bands is shown in the analysis info window It is important that only vertical lanes are allowed and the lanes are always scanned from the top to the bottom If your image s orientation differs use some image manipulation software to rotate it Hopefully there will be some basic image manipulation possibilities in the following version EE 5 1 Detect lanes automatically Define lane When you want to detect lanes automatically you can select the region of interest detection ROI on the image To do this press the define lane detectio
12. n ROI button Left ROI click on the image where you want the upper left corner of the area to be placed EE and move the mouse to draw the rectangle Left click again to finalize the ROI The peiecrlance rectangle s sides can be grabbed with the mouse so you can modify it To delete the ROI right click on the image If no lane detection ROI is defined the automatic lane detection will affect the whole image To detect the lanes press Detect lanes button It is important that the image type is properly set for automatic lane detection Ik 5 2 Delete lane s e To delete the selected lane press the Delete selected lane button Delete selected lane e To delete all lanes press the Delete all lanes button x lt If you delete a lane all the corresponding data will be lost If the deleted lane s Delete all bands were used in quantity or MW calibration the calibration will be recalculated ES If still enough bands are used in the calibrations those will be applied to all lanes 5 3 Add new lane manually puig To add a new lane press the add new lane button Now you can define the new inne lane with 3 clicks on the image First select the upper point of the lane then select the end point Now if you move the mouse you can see that the lanes width is changing Click with the mouse when you have set the right lane width The new lane will be added 5 4 Modify existing lanes Modify To switch to lane modification submode press M
13. odify lanes button The control points lanes of the lanes will be displayed Use the mouse to add new control point delete control points and modify the width of a lane e f you move the cursor above the lane s middle line it will change into crosshair Click where you want the new control point to be on the middle line The new point will be shown and if you don t release the mouse you can move it The lane curves are interpolating spline curves e To move a control point drag it with the mouse e To delete a control point right click on it You can t delete the start and end point of the curve because this would cause the deletion of the lane To delete a lane use the delete lane option e To modify a lane s width grab the left or right side with the mouse and drag it When you modify a lane its profile will be rescanned and if the lane already had bands defined on its profile those will be lost 6 The profile window The profile window displays the intensity profile of the selected lane It also shows the bands on the selected lane and the background if it is defined The horizontal axis of the graph shows the distance from the lane s start position in pixels while the vertical axis shows the intensity values Since all input images are converted into 8 bit grayscale for processing the maximal intensity value is 255 Also the original lane image is shown below the graph The shown profiles values are always scaled to fit t
14. perations take place in the profile window You can select the lanes in bands mode the same way as in lanes mode in the image window FRE 7 1 Automatic band detection Detect bands GelAnalyzer is capable of automatically detecting the bands on lanes To use this oneverylane option press the button Detect bands on selected lane or Detect bands on every El lane When automatic band detection is applied previous bands on the affected lane s will be deleted Detect bands on selected a a 7 2 Add new band manually To add a new band to the selected lane press the add new band button The pe cursor in the profile window turns into crosshair and you can define the boundaries jua of the new band by two clicks The first one defines the new band s start position and the second one defines the end position The band s peak will be automatically calculated as the position corresponding to the maximal intensity value within the new band s boundaries EX 7 3 Delete bands on the selected lane Delete all You can delete an existing band by right clicking in it in the profile window You can bands on delete all the bands on the selected lane at once by pressing the Delete all bands selected lane 5 on selected lane button 7 4 Modify existing bands on selected lane In the profile window you can grab the boundaries of the bands and drag them Also the position of the peak sign can be modified the same way If you
15. tion mode Rf Rf calibration is a very useful tool to repair gel run distortions Rf calibration is calibration performed by defining fix rf values on the image This is done by adding and morg modifying rf curves The rf curves are vertical spline curves Each rf curve defines a fix Til rf value along the image By default the rf value of a band is calculated in comparison Add default With the lane s start and end positions Using rf calibration rf values of bands in lanes start and with different start and end positions become comparable Enabled rf values are end curves from the interval 0 0 1 0 To add a new rf curve press the add rf curve button in H the main window s toolbar The cursor in the image window turn s into crosshair Addrfcurve Click where you want the new rf curve to be placed The start 0 0 and end 1 0 curves are automatically added The new curve s rf value will be calculated automatically You may modify the rf value of the curves except the start and end curves To modify a curve s rf value click in the area that displays the value The rf values of the area s border will turn into orange and you may type in the new value Press ESC to cancel the value modification The start and end curves can be added separately by pressing the add default start and end rf curves button You may add new control points to the rf curves by clicking on them where the cursor turns into crosshair The control points