1. very important table for describing the network and TS User can enter the submenus displayed and edit the values or select the LCN Logical channel number mode and choose whether to insert the NIT If user chooses to insert the NIT information Network ID Network Name LCN Mode Private Data and LCN number of the program mentioned in explanation 6 will be added to the transport stream gt NOTE when the Private Data is set as 0 0 it is invalid 10 EIT EIT Insert As mentioned above 6 the event information table can be chosen whether to insert into the TS or not under this menu If yes the EIT information set above 6 will be displayed on the TV screen Language Code to set the EIT language For example code of the English language is eng If you set the code as eng the EIT displayed will be in English language 11 Bandwidth choose between 6M 7M and 8M 12 Constellation DVB T modulator contains 3 constellation modes 64 QAM QPSK and 16 QAM 13 FFT Transmission Mode Select between 2K and 8K 14 Guard Interval Select among 1 32 1 16 1 8 and 1 4 15 Code Rate It refers to FEC Forward Error Correction rate It contains 1 2 2 3 3 4 5 6 and 7 8 gt NOTE The different combination of bandwidth constellation guard interval and code rate FEC will form a different output code rate Please refer to appendix table 2 16 RF Frequency Adjust it at range of 30 to 999 MHz Set it according your regional situ
2. 11 06 11 71 E ep 1 1 1 1 EG 16 59 18 1 2 00 Table 1 Channel output max capacity in Mbps 11
3. 16 36 dBm 71791 dBuV 0 1db step Management Local control LCD control buttons Language English LCN Insertion yes Upgrade JTAG General Power supply DC 12V Dimensions 153 110 50mm Weight lt 1kg Operation temperature 045 2 Installation Guide and Safety Instructions 2 1 Safety Instructions AS WARNING To prevent fire or electrical shock do not expose the device to rain or moisture gt The encoder modulator is powered with a voltage of 12V DC The power supply voltage must not exceed the recommended voltage which otherwise may cause irreparable damage to the device and the invalidation of the warranty Therefore O Do not replace power supply with a voltage greater than 12V DC O Do not connect the device to the power if the power cord is damaged O Do not plug the device into mains supply until all cables have been connected correctly O Do not cut the cord A avoid placing the device next to central heating components and in areas of high humidity Do not cover the device with elements that obstruct the ventilation slots If the encoder modulator has been kept in cold conditions for a long time keep it in a warm room minimum 2 hours before plugging into the mains Mount the device in vertical position with the connectors located on the top side When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as t
4. FAGOR HTT 101 HDMI YPbPr S Video AV to DVB T Encoder Modulator FAGOR 2 TABLE OF CONTENTS ESPEC ANS e O EN ee eee oo NA A se as ee ee ee ee pet 1 2 Appearance ana Descrip T 33 System Diag laMe tintenna as tA ie ar e aa O A O eta ateiaweede 2 Installation Guide and Safety InstructiONS cennin rin Ea TEE ENEE 2 Sar Y MS TUCU S a AAA AAA ZAS O re ao os db coda de cena dre dd db a de do seat a PP A TE ae a een ee 1 SPECIFICATIONS 1 1 Product Overview HTT Home encoder modulator allows audio video signal input in TV distributions with applications in home entertainment surveillance control hotel Digital Signage shops etc It is an all in one device integrating MPEG4 AVC H 264 encoding and DVB T modulating to convert input signals to DVB T RF out in the frequency range of 30 960MHz The signals source could be from satellite receivers closed circuit television cameras Blue ray players and antenna etc its output signal is to be received by DVB T standard TVs or DVB T STBs etc 1 2 Appearance and Description Air Vent DC 12V HDMI YPbPr S Video AV Oo Y 7 RF IN DC 12V HDMI in RFin RFout Grounding YPbPr S Video AV in Grounding to connect the earth cable DC 12V power input HDMI HDMI stream input supporting HD signals YPbPr S Video AV YPbPr S Video AV signal input through a VGA adapter cable RF in RF Loop through input 10dB attenuation RF out RF output to distribute mod
5. ation or inquire your local services FAGOR 2 17 RF Level Adjust it at range of 16 36dBm 18 RF On User can choose to turn on or turn off the RF under this menu 19 Bit Rate User can read the current modulating bit rate and the maximum bit rate 20 Save Config Yes No to save give up the adjustment of setting 21 Load Saved CFG Yes No to load not to load the saved configuration 22 Reset all sets Yes No choose not choose the factory s default configuration 23 LCD Time out A time limit that LCD will light off Choose among 5s 10s 45s 60s 90s and 120s seconds 24 Lock Keyboard Choose Yes to set a password and lock the keyboard then the keyboard will be locked and cannot be applicable It is required to input the password to unlock the key board This operation is one off If forgetting your password please use the universal code 005599 25 Serial Number User can view the serial number of this device It is read only and unique 26 Version It displays the version information of this device Encoder Modulator the name of the device SW software version number HW hardware version number User can also press ENTER again to view the published time of this device Appendix 8MHz Bandwidth gdl FEC Guard Interval Guard Interval 1 16 1 8 1 16 he weak ability of error correcting and anti interference in this area 7 E N WW N e 0 Ww olo O a a WO m 00 oO uw e
6. ed through the key board and LCD display ENTER MENU LOCK e ee LCD Display It presents the selected menu and the parameter settings The backlight in the display is on when the power is applied LED These lights indicate the working status Oo Power It lights on when the power supply is connected O Alarm It lights on when there is error such as the signal source loss O Lock It lights on when the signal source connected and goes off when the signal lose Left Right Up Down buttons Use these buttons to turn the screen pages shift the target items by moving the triangle or change the parameter settings in the program mode Enter Use this button to enter a submenu or save a new setting after adjustment press it to start adjusting the value of certain items when the corresponding underline flash with Up and Down buttons Hue Enter Hue ap Hue Hue 1 001 001 002 Press it to activate the hidden selections and change the setting with Up and Down or Left and Right buttons Audio Bit rate Enter Audio Bit rate Enter Audio Bit rate 4 Audio Bit rate 128 128 128 192 Menu Press this button to step back Lock Locking the screen cancelling the lock state and entering the main menu after the initialization of the device After pressing lock key the system will question the users to save present setting or not If not the LCD will display the current configuration state When the po
7. he original part Unauthorized substitutes may result in fire electric shock or other hazards Safety check Upon completion of any service or repairs to this device ask the service technician to perform safety checks to determine that the device is in proper condition 2 2 Installation y RISK OF damage to the unit Mechanically handling the unit may result in damage Do not connect the unit to the power supply before or during assembly Connect the unit as below instructed 1 Mount and tighten the screws and plugs to secure the unit to the wall Left 10 cm of free space around from each unit 2 Connect the signal input in the respective connectors The signal source can be from a surveillance monitor DVD set top box CCTV and etc 3 Optionally connect the loop through RF input coaxial cable 4 Connect cable to RF output to STB TV HDMI 5 Power supply connection a Connect the earth cable b Connect the power plug to the unit mains connector c Connect the power plug to the mains socket Cascade Installation HTT Home unit has 1 TV signal to RF output encoded as DVB T Digital TV signal Several HTT Home units can be cascaded in order to increase the Capacity To cascade 2 or more units connect the RF output of the preceding unit to the TV input loop through of the next unit see right illustration TV CAM DVD 3 Operation HTT HOME is controlled and manag
8. ource X XX Mbps the current encoding bit rate 2 Alarm Status For example if the CVBS cable disconnected it will display Video 1 Not Lock under this menu 3 Uptime It displays the working time duration of the device It times upon power on 4 Video Parameters User can enter the items respectively to view the video status and signal source resolution and set the input interface User can also adjust values of rest items Bit rate 0 500719 500 Mbps Brightness amp Contrast amp Saturation 0 255 Hue 128 127 5 Audio Bit rate Select audio bit rate among 64 96 128 192 256 320 384 kbps Audio Format Select audio format among MPEG2 LC AAC and HE AAC 6 Program Information User can enable or disable the program output under menu Program Output User can also enter the other items to edit the Service Name Program Name Program Number and PIDs of PMT PCR Video and Audio and edit LCN Logical channel number E T Event User can enter this menu to setup EIT Event Information Table for the current and next program event The EIT contains Start Year Start Time Duration and Event Name of the event All the EIT information can be displayed on the TV screen on condition that the EIT is chosen to insert see explanation 10 7 TSID Transport Stream ID User can view or adjust after enter this menu 8 ONID Original Network ID User can view or adjust after enter this menu 9 NIT Network Information Table NIT table is a
9. ulated signal 30 960 MHz 71791 dBuV LCD Window Control Buttons Indicators Air Vent JTAG port for upgrade 1 3 System Diagram 4 we T T NA Surveillance Monitor Camera Closed Circuit TV PC 1 4 Characteristics Encoding Section Video HDMI Video YPbPr CVBS S Video Modulator Section Standard Bandwidth Constellation Code rate Guard Interval Transmission Mode MER RF frequency RF output level System Encoding Interface Resolution Bit rate Encoding Interface Sample rate Bit rate Encoding Interface Resolution Bit rate Encoding Interface Sample rate Bit rate DVB T COFDM 6M 7M 8M HTT HOME Encoder Modulator Attenuation 10dB TV AV to the distribution network Antenna MPEG 4 AVC H 264 HDMI 1920 1080_60P 1920 1080_50P 1920 1080_60i 1920 1080_50i 1280 720_60p 1280 720_50P 0 500 19 500 Mbps MPEG1 Layer Il MPEG2 AAC MPEG4 AAC available HDMI 48KHz 64 96 128 192 256 320 384kbps MPEG 4 AVC H 264 CVBS 1 YPbPr 1 S Video 1 CVBS amp S Video 720x576_50i PAL 720x480_60i NTSC YPbPr 1920 1080_60i 1920 1080_50i 1280 720_60p 1280 720_50P 0 500 19 500 Mbps MPEG1 Layer II MPEG2 AAC MPEG4 AAC available 1 Stereo mono 48KHz 64 96 128 192 256 320 384kbps QPSK 16QAM 64QAM 1 2 2 3 3 4 5 6 7 8 1 32 1 16 1 8 1 4 2K 8K gt 42dB 307960 MHz 1KHz step
10. wer is connected the LCD will start to initialize the program The LCD menu goes as below chart 0 Initializing 1 Up Down gt Enter lt Menu y Lock DVB T 506 000MHz 1 5761 6 93Mbps Status Alarm Uptime o n Encoder Video Video In Status Resolution Interface Video Bitrate Rate Mode Profile Level Brightness Contrast Saturation Hue Encoder Audio Audio Audio Bitrate Audio Format Encoder Program Info Program Info Program Output Service Name Program Name Program Number PMT PID PCR PID Video PID Audio PID LCN EIT Event Stream Network ID Network Name LCN Mode Private Data NIT Insert EIT Language EIT Insert _ _ _ _________ K FAGOR 2 ca e Modulator Bandwidth SM 7M 6M Modulator Constellation 12 Constellation gt 640AM Modulator FFT 13 FFT P2K 8K mim CH Guard Interval 1 32 Code Rate 7 8 15 RF Frequenc 650 000 MHz a RF Level 10 0 dBm RF On Off On Modulator Bit Rate val max Bit Rate 6 986M 31 668M System Save Config Yes gt No System Load Saved CFG 21 Load Saved CFG Yes gt No System Reset all sets karma Fi em 2 System LCD Time out 23 LCD Time out 30s System Lock Keyboard Lock Keyboard Yes No Serial Number 25 Serial Number 70ec8 7b0000f System Encoder Modulator Version SW 0 11 HW 12D 1 DVB T modulating standard XX XXX MHz the current output frequency 576i video resolution of signal s
Download Pdf Manuals
Related Search
Related Contents
Télécharger le PDF Lullaby Resus Plus Brochure PDF 471KB Instalación del controlador táctil serial Vol.10(H.20_4発行) DeLonghi PRO1860X steam ironing station Genius Heeha 300 Samsung Aegis Washer with Volt Control, 6.2 kg, White Lietotāja rokasgrāmata manual ingreso de productos bodega DELL Vostro 470 I N F O R M A T I O N Copyright © All rights reserved.