ARTESIS AMT QUICK INSTALLATION GUIDE

image

Contents

1. clips to the motor terminals or other location for direct contact with the conductors Connections for Low Voltage lt 480V AC Medium Voltage gt 480V AC and Inverter Driven equipment are described Follow the steps appropriate for the motor type 3 1 Low Voltage Motors For 5 Amp AMU plug current socket to AMT Toolkit connect current cables to multi ratio current transformers supplied with AMT Toolkit and connect multi ratio current transformers to equipment s 3 phase supply cables Connect current cables to multi ratio current transformers as described below according to motor s nominal current GOSB TeknoParki Hightech Binasi Kat 3 B 10 41480 Gebze Kocaeli Turkey P 90 262 678 8860 F 90 262 678 8855 artesis artesis com www artesis com 3 2 Shoe CT1 CT2 CT3 Connect C1 C3 and C5 current cables to S1 terminals of CT1 CT2 and CT3 respectively If nominal current is between 30 100 Amps connect C2 C4 and C6 to S2 terminals as shown in the figure above If nominal current is between 100 200 Amps connect them to S3 terminals If nominal current is between 200 300 Amps connect them to S4 terminals If nominal current is between 300 400 Amps connect them to S5 terminals If the MCC has existing current transformers make direct connections to those current transformers with 5 Amp secondary output If the nominal current is between 0 30 Amps and current transformers do not exist at the measuremen
2. ARTESIS AMT QUICK INSTALLATION GUIDE pe a Artesis Artesis Asset Management Toolkit AMT Before installation 1 Ensure that AMT Toolkit includes all cables Voltage measurement cables Fluke AC285 SureGrip Alligator Clips current measurement cables power cable cross cable for ethernet connection computer and its charging adapter 2 Ensure that battery power of the computer is not low or charging cable is connected to the computer 3 Check the Motor Control Cabinet MCC for installation of split core current transformers CTs which are included within AMT Toolkit a If itis suitable then check the motor name plate for rated current in order to use appropriate transformation ratio b If not check usability of existing CTs 4 Check the secondary output of CT which is used for measurement in order to use the appropriate Asset Management Unit AMU 5 Check the license status of the software to get the report of the data Installation 1 Before setting up the AMT Toolkit ensure that motor is not running and all switches are off 2 Plug the power cable 3 Connect cross cable to the computer Current amp Voltage Connections 1 Select appropriate 1 Amp or 5 Amp AMU for voltage and current connections AMU for 1 Amp is provided for direct connections to the existing current transformers with 1 Amp secondary outputs of the motors with measurement units Plug voltage sockets to AMT Toolkit and connect the alligator
3. button Wait for the AMU device to finish Learn and Improve modes and to get into Monitor mode Right click on the device and select Waveform submenu Download waveform data until Save icon enabled and save it to a text file Close the waveform window By clicking the AMT Report menu open reporting user interface If the company information was not recorded before click on Companies group on the left bottom on the reporting user interface or Company menu GOSB TeknoParki Hightech Binasi Kat 3 B 10 41480 Gebze Kocaeli Turkey P 90 262 678 8860 F 90 262 678 8855 artesis artesis com www artesis com 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Click New Company button on the Company ribbon bar and fill the company information on the right pane Click Save button on the ribbon bar On the motor pane click Add New Motor button Fill the motor information on new motor card Click Save Motors button A motor can be removed by clicking Remove Motor button Motor adding editing operations can be cancelled by clicking Cancel Editing button Click Report menu or Reports group on the left bottom The companies and their motors will be listed on the left pane Click the New Report from DB button The AMU devices and their data are listed on the right pane Assign waveform text file by clic
4. king the folder icon Drag a data from that list and drop into the related company s motor on the left so that the data can be assigned to a specific motor and a report is opened If you did not assign a waveform you can assign it by selecting a report on the left and clicking Assign Waveform File button A report can be viewed by double clicking on it The report will appear on the right pane A report can be exported as pdf file e mailed as attachment or previewed to print using the Export E Mail and Preview and Print buttons on the ribbon bar respectively The PSD and waveform graphs of a report can be viewed by clicking PSD and VI Waveform tabs respectively When data acquisition is done 1 2 3 4 Ensure that motor is not running Turn voltage AMU and power fuses off in order Remove current transformers Disconnect power voltage and current cables GOSB TeknoParki Hightech Binasi Kat 3 B 10 41480 Gebze Kocaeli Turkey P 90 262 678 8860 F 90 262 678 8855 artesis artesis com www artesis com
5. t unit of the motor use current transformers NOT SUPPLIED with appropriate turn ratios Turn ratios will be selected such that current inputs are between 1 5 5 Amps for 5 Amp AMU and between 0 3 1 Amps for 1 Amp AMU Medium Voltage Motors The test equipment has a limit of 480 volts for direct connection Therefore testing on medium to high voltage motor and driven equipment is performed by utilizing secondary circuit low voltage to access the currents and voltages Lethal voltages and currents are present at the input terminals of this device Accordingly this unit must be used in accordance with all local and national codes for the installation and operation of low voltage electrical equipment Inverter Driven Motors Make sure that voltages are measured at the output terminals of the inverter Direct connections to the output terminals are made for low voltage GOSB TeknoParki Hightech Binasi Kat 3 B 10 41480 Gebze Kocaeli Turkey P 90 262 678 8860 F 90 262 678 8855 artesis artesis com www artesis com a inverters Voltage transformers NOT SUPPLIED are needed for medium voltage inverters Turn the power switch of the AMT Toolkit and AMU unit on Ensure that AMU s Power led is on Ensure that IDLE message appeared in the AMU s LCD display If the unit is not in IDLE mode press clear button until IDLE message appears in the LCD display Refer to section 3 in user manual for detailed information for the use of AMU
6. unit Configuring AES for AMT Software Configuration of AMU unit using the set up wizard is described below Alternative configuration is possible from the front panel by using the buttons of the AMU unit as described in section 3 in user manual 1 ee Oe a 12 13 14 15 16 17 18 19 20 21 22 Before configuring AES Configuration Application ensure that motor is running and voltage amp current sockets are connected Select AMU model on the AES panel according to secondary amps value of current transformers AMU 1A or AMU 5A Right click on it Select the Setup Wizard menu item Click Next button Enter equipment s Nominal Voltage Nominal Current Frequency and Motor Speed Choose connection type Click Next button Enter voltage transformers conversion ratio Default value is 1 If there are no voltage transformers used leave the conversion ratio as 1 Click Next button 11 Enter current transformers conversion ratio Default value is 1 e g If the 100 5A is used set the conversion ratio as 20 Click Next button Wait for 90 seconds Click physical parameters button to see the measured parameters Ensure that electrical values currents voltages are same as expected and phase ordering see section 3 4 4 in user manual for detailed information is right Click Close button Click Next button Click No

Download Pdf Manuals

image

Related Search

Related Contents

Recipes - Lakeland  Pioneer X1 Installation Guide  Electrolux EMS26405 User's Manual  PresTop GT Table Slim Universal  Transcend TS128GMSM360 solid state drive  PDST24/PDST32 GASOLINE SNOW THROWER  Rexel Standard L Folders  Mode d`emploi du moniteur/défibrillateur LIFEPAK  IDEAL Security SKGLWBLUS Installation Guide  Maxell CR  