Home

Quick Reference IM483 & IM805 - Schneider Electric Motion USA

image

Contents

1. 9 8 1 Z ADJ upply O Ooo py No V Break ae Direction Switch L ae If an Opto Supply voltage greater than 5 VDC is used a current limiting resistor is REQUIRED in series with the Input Copyright Schneider Electric Motion USA www schneider electric motion us Alternate Connector Options 8 Pins at P1 The pin out is identical to standard IMx products IMx 8P2 8 Pin Posts at Connectors at P1 and P2 8X 0 045 1 14 SQ Post Tin Plated Bronze 8X 0 025 0 64 0 200 SQ Post Tin Plated Bronze Connector P1 Connector P2 IMx PLG 8 Pin Locking Pluggable Connectors at P1 and P2 a 8X 0 040 1 02 SQ Post Tin 4 Plated Bronze Connector P1 and P2 Orientation Alternate Connector Options 34 Pins at P1 The pin out allows for additional signals See table below IMx 34P1 34 Pin Header at P1 Standard Screw Terminal at P2 34X 0 025 0 64 0 220 0 100 SQ Posts Tin 5 6 2 54 Plated Bronze 0 100 2 54 YY _ 0 500 BR OOL Gen PCCP Tr E See Connector P1 18 34 IMx 34P1 8P2 34 Pin Posts at Connectors at P1 and 8 Pin Posts at P2 8X 0 045 1 14 8X 0 025 0 64 0 100 SQ Post Tin 2 54 Plated Bronze 0 100 0 200 SQ Post Tin 2 54 5 1 J Plated Bronze 0 520 0 811 20 6 0 800 13 2 aa 23 2 yo 0 3 y Connector P2 POET Connector P1 Pin Function Pin 3 Res
2. Condition Min Typ Max Unit 1 0 Specifications e a Output Current Fault Fullstep Outputs Collector Emitter Voltage Fault Output Esa J 7 0 5 Isolated Inputs 1 5 7 a 10 65 Collector Emitter Saturation Voltage Fault 1 25 mA Drain Source Voltage Fullstep Output 70 15 as Es a CS Thermal Specifications Min Typ Max Unit Storage Temperature CT A aa ee Ambient Temperature oje Plate Temperature Add t Cooling may be required 70 C Motion Specifications Min Typ Max Unit Step Clock Rate TC l o d Number of Microstep Resolutions See Resolution Table 14 All documentation software program examples and resources are available online at http www imshome com products discrete_drivers html Mechanical Specifications Dimensions in Inches mm 2 75 0 15 69 9 3 8 3 00 76 2 2 42 61 4 P2 Pin 1 0 29 4X 0 190 4 1 7 4 4 1 HMAX IM483 1 20 30 5 IM805 1 32 33 5 Pin Configuration See Opposite Side for alternative connector options Connector P2 Motor and Power Function 6 MotorPhaseB 8 MotorPhaseA Connector P1 Signals Pin Function Pin 1 Step Clock Input Direction Input 6 Resetinput 8 Fullstep Output Mounting Requirements The IMx is designed to be mounted to a heat sink or inside a panel IMS offers both a Heat Sin
3. IM483 amp IM805 Miniature high performance microstepping drivers Quick Reference iMS Schneider E a PP Electric Notes and Warnings Installation configuration and maintenance must be carried out by qualified techni cians only You must have detailed information to be able to carry out this work This information can be found in the user manual e Unexpected dangers may be encountered when working with this product e Incorrect use may destroy this product and connected components The user manual are not included but may be obtained from the Internet at http www imshome com downloads manuals html Required for Setup 12 to 48 VDC 2A IM483 or 24 to 75 VDC 3 5A IM805 unregulated linear or switching power supply Stepping motor appropriately sized for your drive 22 AWG wire for logic and I O 18 AWG wire IM483 or 16 AWG wire IM805 for power supply Shielded twisted pairs recommended Basic hand tools wire cutter stripper screw driver General Specifications Electrical Specifications Condition Min Typ Max Unit imputvotageRange HM oo ooo a E a LG j e pisos Cid 75 VOC mes H o aM Peak 4 4 A mso PS 1 50 A Peak 70 A Phase Output Current VO Floating 70 IM483 EA fovmrocornt ace vo Featng 1 is F ma oe IM483 lu ARMS 12 W was tore ars 9 w
4. k Kit H 4X and Side Mounting Clips U3 CLP H 4X Heat Sink Kit 6 00 152 4 5 50 0 85 139 7 i 21 6 le 6X32 Threaded 4 Places 4 6 32 x 1 2 Screws 4 6 Split Lock Washers 4 6 Flat Washers 1 TN 48 Non lsolating Thermal Pad Adhesive Side to Drive ba Pee H 4X Heat Sink U3 CLP Side Mounting Clips AN IM483 or IM805 A 10 Mounting Hardware Not Supplied 2 U3 CLP Mounting Clips Mounting Panel or Plate IM483 and IM805 Quick Reference R021610 Controlling the Output Current A Current Adjustment Resistor is REQUIRED to operate the IMx driver Optionally the output current may be automatically reduced to a holding current level after a motion completes A Current Adjust Resistor AN 1 8W 1 Q See EQ A s Reduction Adjust Resistor 1 8W 1 Q See EQ B EQ A RapJ Ipeak X 500 EQ B M l RUN xX RED 900 X RUN Connecting Motor and Motor Power This document shows connection of Max Inductance Per Phase mH a 4 lead stepping motor For 6 and id IM483 IM805 8 lead motor connection see the prod 12 25 uct manual Use the table on the right 24 to determine the acceptable per phase inductance Linear Unregulated or Switch Mode IM483 12 to 48 VDC 10 Ripple IM805 24 to 75 VDC 10 Ripple pm E Phase A PGGGHHYS 876543 OQ Q Stepping M
5. olution Select3 16 26 On Full Step Output 4 Step Clock Input 21 Step Clock Output Non tsolated _ 6 Direction Input 22 Direction Output Non Isolated _ 23 Resolution Select0 24 Resolution Select4 25 i ed Function 8 Optocoupler Supply 10 Enable Disable Input 12 Resetinput 14 FautOutput Step Direction outputs follow the inputs at a 1 1 Ratio Resolution Select 2 Logic Ground Non lsolated BB 34 Breakout Board 2X 0 155 3 94 1 050 26 67 O0000000 O0000000 0 780 19 81 4 Pin 10 Enable Input Pin 8 Opto Supply Pin 12 Reset Input Pin 14 Fault Output Pin 16 On Full Step Output Pin 6 Direction Input Pin 3 MSEL3 Pin 21 Step Out Pin 22 Direction Out Pin 23 MSELO Pin 24 MSEL2 Pin 27 Ground Pin 26 On Full Step Output Pin 25 MSEL1
6. otor Opto lsolated Inputs Current Limiting Resistor Values VDC 5 10 12 15 24 5 VDC RUMIT 681 1000 1300 2670 Controller Opto Supply P1 4 Isolated Input Output Controller Output P RLIMIT 1 4 W 1 Isolated Input Open Collector Interface TTL Interface Setting the Microstep Resolution 1 MSELO ON LOW O 2 MSEL1 3 MSEL2 4 MSEL3 1 OFF HIGH 1 2 1 3 gt 4 MSEL Switch Resolution MSELO MSEL1 MSEL2 MSEL3 Microsteps Step StePS Rev SW1 4 SW4 2 SW1 3 SW1 4 Binary Resolutions O 2 40 Ooo o 4 ww 1 Oo 8 amp 8 10 0 pt 320 1 o 32 ao o E E pe En 2 4 1 16 1 32 64 12800 1 28 25600 2e 520 1 1 1 0 Decimal Resolutions O o 5 0 o o o 1i o 10 1 o 5 5w o0 50 10 1 125 20 0 250 50000 1 Minimum Required Connections The following illustration shows the minimum connection requirements for operating the IMx For use and interface of the other I O Points please refer to the full product manual All Opto lsolated inputs should be referenced to co 4 f t Mot the Opto Supply Ground O L as Stepping otor eS ey for Isolation Not Drive f Power Ground Z 2 7 Q Phase A A s o fereg rare diola 5 e Phase B 5 VDC ll s P1 P2 2 V Supply ll s 3 l GND 7 2 3 v o Step Clock