Home

User Manual

image

Contents

1. code Do not leave this quick reference guide with your user codes near the control panel 15 4 02 USER PROGRAMMING NOTES Function FaeenySetings Usersetinge eco zann er ae an an TI enmezonee Sd HEN Zu EEE an a oma S Note The alarm system can provide valuable protection for your home and property if used properly However the system can not guarantee complete protection against burglary or robbery Therefore the manufacturer distributor or supplier will not be held responsible for any loss or damage that may occur Every effort has been made to provide accurate information however slight variations can occur We reserve the right to make changes for product improvement at anytime 16 PROBLEM AND FAULT INDICATION Mains LED Fault Call installer if you do not have a Flashing Mains general mains power failure Mains LED Fault Call installer to check the battery if Flashing Mains Battery LED remains on Mains LED Fault Call installer to check the battery if Flashing Battery LED remains on Fault Enter user code LCD displays zone in fault Call installer if fault can not be cleared Internal Siren Fault Call installer if you can not clear Sounds Tamper the fault System Does not Fault Check zone to see if you can clear Set Zone the fault if not OMIT that zone from system and call installer to Keypad Accepts Personal Attack Panic button not reset also press No Presses RESET button on ST5500 Ke
2. is unable to disarm secure zones This is useful if you have a cleaner whom you do not want to enter any particular area To enable user code 6 from user programming mode Enter New Code Press ES User 6 Enter a 4 digit number Do Not use 0 0 0 0 as this will disable the user code After accep tance of each code a double beep is given and the system returns to user programming 3 04 Setting Secure Zones Secure Zones act as normal zones except if the system is disarmed by user code 6 where upon those zones programmed as secure zones remain armed If a Secure Zone is activated after the system has been disarmed by user code 6 internal sirens will sound only User code 6 can silence the alarm and arm the system again but can not reset the secure zones Upon enter user code master or user codes 2 5 the secure zone or zones will flash indicat ing activation After entering your user code press RESET to reset the system To set secure zones from user programming mode Secure Zones None Enter zone numbers to set as secure zones zone LED will flash if set as secure zone Toggle corresponding zone key number to enable or disable secure zones Example Programming zone 2 as secure zones from user programming mode Secure Zones Press 7 None Press 2 Secure Zones Zone 2 User Programming Press RESET 12 3 05 Setting Chime Zones If a zone programmed as a chime is activated in day mode the intern
3. ST5500 User Manual CONTENTS Section Page No 1 00 Introduction 2 1 01 ST5500 Control Panel 2 1 02 K6600 LCD Remote Keypad 2 1 03 SL6600 Sleep Watch Remote Keypad 3 1 04 AD1000 Voice Dialer 3 2 00 User Operation 4 2 01 Day Off Mode 4 2 02 Full Guard Arming 4 2 03 Part Guard Arming Option 1 5 2 04 Omitting Zones Full Guard 5 2 05 Omitting Zones Part Guard 6 2 06 Activating amp Resetting Keypad Panic 6 2 07 Disarming System Using Keypad 7 2 08 Disarming System After Activation 7 2 09 Arming amp Disarming Part Guard Option 2 8 2 10 Arming and Disarming Sleep Watch Zones 8 2 11 Activating Sleep Watch Panic Button 8 2 12 Silencing Panic Alarm Activation 9 2 13 Memory Recall 9 2 14 Displaying Faulted Zones 9 2 15 Intelligent Auto Reset 10 2 16 Mains Supply Failure Indication 10 2 17 Mains Supply Failure and Low Battery Indication 10 2 18 Low Battery Indication 10 2 19 Service Required 10 3 00 User Programming Section 11 3 00 Entering User Programming Mode 11 3 01 Changing Master User Code 11 3 02 Enable User Codes 2 5 11 3 03 Enable User Code 6 12 3 04 Setting Secure Zones 12 3 05 Setting Chime Zones 13 3 06 Exit User Programming 13 4 00 System Test 14 4 01 Quick User Reference Guide 15 4 02 User Programming Notes 16 4 03 Fault Indications 17 1 00 Introduction Thank you for choosing Melcom s security control panel we are committed to bring to you tomorrow s technology today The installation engineer has fitt
4. al siren and K6600 LCD remote keypad will beep to indicate activation of that zone This allows you to monitor children or people in your premises or home To set chime zones from user programming mode Chime Zone press Le None Enter zone numbers to set as chime zones zone LED will flash if set as chime zone Tog gle corresponding zone key number to enable or disable chime zones Example Programming zone 1 as a chime zone from user programming mode Chime Zone Press ee None Press 1 Chime Zone User Press RESET Programming 3 16 Exit User Programming To exit user programming and return to day Mode Press RESET System Ready 13 4 00 System Test It is recommended that you test the system once a week to ensure that it is working correctly To test the system En ST5500 amp K6600 Press PROG All Red LEDs illuminate LCD DISPLAY Master User 2 2 ues User Code Programming Press Co System Test Press Tests strobe System Test Strobe System Test Press Tests external siren External Siren f System Test Press Tests high volume internal alarm Volume High Press Tests low volume internal alarm System Test Volume Low Testing sensors and detectors follow Press Manufacturer s instructions supplied with o t units on how to test in this manner Pr s Co Exits system test and returns to user pro System Test ar gramming Press RESET RESET Exits user programming a
5. cause the system to lock up the system will not function until the reset key has been pressed If your system has been programmed to be reset after an alarm activation by your installer After silencing the alarm you will need to contact your installer to reset the system 2 09 Arming amp Disarming Part Guard Option 2 If your system is fitted with a SL6600 sleep watch keypad the system can be part guard armed and disarmed by using this keypad providing that this function has been enabled by your installer for 3 seconds key illuminates green and System Armed Press SLEEP gives 1 beep Part guard is now armed Press SLEEP gives 2 beeps Part guard is now dis System Ready armed sr for 3 seconds key light extinguished and 2 10 Arming amp Disarming Sleep Watch Zones Sleep Watch zones act in the following way When the system is part guard armed Sleep Watch zones remain unarmed until the sleep button on the sleep watch has been pressed These zones can be disarmed by using the sleep watch button either permanently or tem porary timed This is useful should you need to go to the bathroom or kitchen at night If a Sleep Watch zone is activated it will not activate the alarm immediately but give a timed delay to enable you to enter your user code into the system keypad The sleep watch keypad will a give corresponding number of beeps to indicate which zones has been acti vated p i for 1 second key illuminates green S
6. ed your alarm system and explained the operation of the control panel For your reference the basic instructions are printed on the inside back cover of this booklet for you to cut out and keep in a safe place This booklet is designed to explain in more detail the operation of your control panel and how to re program the user options 1 01 ST5500 Control Panel The ST5500 control panel as 5 zones one of which is dedicated as a Tamper zone The main control unit allows autho rized persons to arm amp disarm the system In the event of an activation the main unit will activate visual and audible devises attached to the system If the system is found to have a fault STEEDS _ this will be indicated on the LCD s Display T L 1 02 K6600 Remote LCD Keypad The K6600 LCD remote keypad is available as an accessory for the ST5500 The K6600 remote keypad gives full system information on its 16 X 2 LCD display All zones can be given a name se lected from a predetermined list This helps to identify any zone that is in fault or as activated also date and time of activation is displayed Up to 2 LCD remote keypads can be fitted to any ST5500 control panel 1 04 SL6600 Sleep Watch Remote Keypad The SL6600 Sleep Watch Remote Key pad is available as an accessory It incorporates a digital Panic Button and is also used for arming and disarming Part Guard and Sleep Watch zones If you need to go to the bathro
7. il RESET button has been pressed 2 07 Disarming System Using Keypad When returning to the premises enter via the ENTRY EXIT Zone This will activate the en try tone for length of ENTRY time as programmed by your installation engineer To prevent the activation of the alarm before the elapse of the ENTRY time you must enter any valid user code The keypad sounder will speed up when entry time has nearly timed out Example disarming system NOTE Entry tone will speed up before sounding the internal alarm If after 30 seconds still no valid user code has been entered the external siren will sound The keypad will lock up for 2 minutes if after 15 key presses no valid code is recognised 2 08 Disarming System After Activation When returning to the premises enter via the ENTRY EXIT Zone This will activate the en try tone for length of ENTRY time as programmed by your installation engineer Enter a valid user code to disarm the system and press RESET Example disarming system after zone 5 activation 4 Zonos Zone 5 LED illuminated System Read The activated zones will be indicated on the LCD Display giving zone number or name Note which zone or zones have activated Enter your user code and press the reset key After resetting the system investigate those zones which have been activated Any activation caused by a Tamper fault has to be cleared before the system can be reset Note Failure to reset the control panel will
8. nd System Ready returns to Day Mode 14 4 01 QUICK USER REFERENCE GUIDE Full Guard Arming Option 1 Enter User Code Leave premises via exit route Full Arming Guard Option 2 Press SET 3 seconds Leave premises via exit route Part Guard Arming Option 1 Enter User Code Press SET Leave to none pro tected area of building Part Guard Arming Option 2 Sleep Watch Keypad Sleep Button illumi Press SLEEP for 3 seconds nates Red Silent Set Press PROG during exit time Keypad no beeps Omit Zones Full Guard Press OMIT after entering Omit LED illuminates user code enter zone number Press OMIT Omit Zones Part Guard Press OMIT after entering Omit LED illuminates user code enter zone number Press OMIT SET Full Guard Disarming Enter User Code Day LED illuminates Part Guard Disarming Option 1 Enter User Code Day LED illuminates Part Guard Disarming Option 2 Sleep Watch Keypad Sleep LED Press SLEEP for 3 seconds extinguishes Disarming After Alarm Activation Enter User Code Day LED illuminates Press RESET Panic Keypad Press SET OMIT SET SOS Day LED flashes Memory Recall Press PROG Enter Master Last Activation Display User Code Press MEM First Note To use those options marked with ask your installation engineer to program them Important If after 14 key presses a valid code has not been entered the keypad will not accept any entries for 2 minutes You must wait then re enter your user
9. om in the night simply by pressing the sleep button all Sleep Watch zones will disarm but perimeter zones will stay armed If the system is activated the Sleep Watch keypad will give corresponding beeps to indicate which zone has activated so that you know which part of your premises the intruder is located Up to six SL6600 Sleep Watch remote keypads can be fitted to any ST5500 con trol panel 1 05 AD1000 Voice Dialer The AD1000 Voice Dialer can be con nected to the ST5500 control panel In the event of your alarm activating the AD1000 will telephone the pre programmed numbers and play a voice message to your telephone let ting you know that your alarm has activated Up to 8 telephone numbers can be programmed and a single voice mes sage of up to 20 seconds recorded 2 00 USER OPERATION 2 01 Day Off Mode This is the normal default setting of the control panel The alarm will sound if the following types of zones are activated in Day Mode and also to indicate faults Type of Alarm or Fault Panic Personal Alarm PA Full alarm external and internal sirens sound Fire Detection Zones Full alarm external and internal siren intermittent sound 24 Hour Alarm Internal sirens only Tamper Fault LCD display fault tamper and internal sirens sound Zone Fault Day LED flashing LCD display fault 2 02 Full Guard Arming In FULL GUARD armed state zones connected with intrusion detectors to the control
10. panel will detect any unauthorised entry and set off the internal and external alarm Make sure all zones and P A Panic Alarm loops are closed The control panel will not switch to the armed mode if they are open Full Guard Arming is indicated by the internal speaker beeping during exit time count down ST5500 amp K6600 LCD Display To arm the system enter a valid user code System Ready Example EXIT time is delayed whenever a zone is opened or in fault e g a door contact on the front door is opened Count down System Armed will resume when the zone is closed omitted or fault re moved Note System can be quick set by pressing Set key for 3 seconds if this feature is enabled by your installation engineer 2 03 Part Guard Arming Option 1 PART GUARD means that the system is only armed in pre set zones allowing you to oc cupy or pass through the unarmed zones This is normally used for night time setting of the alarm system to isolate the bedrooms Enter a Valid User Code and press SET within 5 seconds System Ready Example PART GUARD mode will become armed within 5 seconds or System Armed the time programmed by the engineer You should leave or go to a non armed part of the building Note If you have zones programmed as Sleep Watch zones these can only be armed after Part Guard arming and pressing the sleep button on the sleep watch remote keypad 2 04 Omitting Zones Full Guard You might wish to omi
11. ry 2 19 Service Require Day LED flashing and system arms Service Required Service Required 3 00 User Programming Section You can adjust several control panel settings by entering User Programming MODE To enter user programming from Day Mode press PROG and enter your Master User Code Press All Red LEDs illuminate You are now in user programming mode follow the instructions to make any changes allowable under user programming Note Only the master user code can make any changes in user programming mode 3 01 Changing Master User Code It is advisable to change your master code from the factory default setting 1 2 3 4 It is important that you do not forget this code as no programming changes can be made in ei ther user or engineer programming without entering this code Enter New Code Master Enter a new 4 digit number do not use 0 0 0 0 After acceptance a double beep is given and unit returns to user programming 3 02 Enable User Codes 2 5 User Codes 2 5 are disabled and can be enabled by entering the following programming locations Enter New Code User 2 Enter New Code User 3 Press Press 2 Press 3 Press 4 Enter New Code User 4 Enter New Code User 5 Enter a 4 digit number Do not use 0 0 0 0 as this will disable that user code After accep tance of code a double beep is given and the system returns to user programming Press 5 11 3 03 Enable User Code 6 User code 6
12. t activation is displayed first Only the master user code can recall the activa tion memory log To recall alarm activations Press enter _ ce Sea DD MM YY HH MM Press MEM Personal Attack Keep pressing MEM to go through the activation log i System Read Press RESET aoe memory recall and return to day 2 14 Displaying Faulted Zones If a zone is found to be in fault this is indicated by the day LED flashing To check which zone is in fault enter a valid user code and note which zone LCD is displayed A tamper fault is indicated immediately on the LCD Display cites Zone 5 Note System can not be armed unless the zone fault is cleared or omitted from the system when arming 2 15 Intelligent Auto Reset If the panel has activated whilst you are away once the alarm time as timed out the panel will automatically reset The alarm will activate once more should another zone be acti vated or if the zone that originally activated is closed Upon entering the premises the strobe will be flashing to indicate system has been activated Enter a valid user code and note which zones have activated then press RESET key 2 16 Mains Supply Failure Indication Fault Mains LED flashing No mains supply Mains 2 17 Mains Supply Failure and Low Battery Indication Mains LED flashing No Mains and _ Fault Low Battery Mains Battery 2 18 Low Battery Indication Mains LED flashing Low Battery eee ow Batte
13. t zones in full guard before arming the system For example you can omit the zone that protects the garage Enter a valid user code and press OMIT enter zone number to be omitted and press OMIT Example Omitting zone 2 Enter System Arming Zones omitted will be reintroduced to the system once the system has been disarmed If you wish to have a zone disabled from the system you must contact your installation engineer Note PA Tamper Fire Zones amp 24 Hour Zones can not be omitted 2 05 Omitting Zones Part Guard You might wish to Omit Zones in Part Guard before arming the system For example you can omit the zone that protects the kitchen Enter a Valid User Code and press OMIT enter zone number press OMIT and SET Example Omit Zone 6 Enter System Arming Zones omitted will be reintroduced to the system once the system has been disarmed If you wish to have a zone disabled from the system you must contact your installation engi neer Note PA Tamper Fire Zones amp 24 Hour Zones can not be omitted 2 06 Activating amp Resetting Keypad Panic If the control panel is armed or in day mode activating of the Keypad Panic will sound the external and internal sirens To silence the alarm enter any USER CODE day LED will flash and press RESET Example pies S o Silence alarm after keypad activation Note If you do not press RESET after entering your code the control panel will not operate unt
14. ypad Accepts Keypad Tamper Activated Wait 2 minutes and try again If no No Presses correct code entered after 3 at tempts the keypad stops working for 2 minutes Note There are no user serviceable parts contained within this control panel DO NOT attempt to interfere with or alter any of the electronic components To do so may damage the electronic circuitry and will invalidate your warranty 17
15. ystem Armed ress SLEEP Sleep watch zones are armed sucer for 1 second key illuminates red Sleep System Armed Press SLEEP watch zones are disarmed Note If sleep watch automatic rearm is programmed by your installer sleep watch zones will rearm automatically after the time preprogrammed by your installer and the sleep button illuminates green when zones are rearmed 2 11 Activating Sleep Watch Panic Button The sleep watch keypad has an integrated digital panic button which can be activated by pressing for 1 second This will activate a full alarm I ie both internal and external sirens Twice within 5 seconds key flashes green Alarm Press PANIC Internal and external sirens activated 2 12 Silencing Panic Alarm Activation If your system is fitted with sleep watch remote keypads push panic button and has been activated by pressing the button or entering the panic keypad alarm sequence enter a valid user code and press reset to silence the alarm te chee Press RESET System Ready Note If the is alarm activated by using a panic button after entering your user code you must reset the button using a reset key supplied with the unit If you do not reset the panic button the alarm system will not function until the panic button is reset and the reset button on the keypad is pressed 2 13 Memory Recall The control panel can recall the last 50 activations and can also give the date and time of activation las

Download Pdf Manuals

image

Related Search

Related Contents

Telecharger le document  Lowel Light LOWEL CASELITE 2 User's Manual    1 La littérature de jeunesse à l`école, au collège et au lycée CDDP  Samsung SGH-U900G Felhasználói kézikönyv  User Guide to Record of Comments  Fujitsu FUTRO A250  USER GUIDE - Mitel Edocs  obligations comptables  1 2 3 4 5 Suivi subvention de fonctionnement - Mode d`emploi  