1. Flash On Off Off Flash strobo On Flash On strobo RED Meaning abbreviations Off DB lamp off by dimmer switch SHORT Short circuit or defective lamp On DB Lamp on by dimmer switch HTP High temperature protection active Off Brake Lamp off by maxi controller HVP Too high voltage power supply On Brake Lamp on by maxi controller LVP Low voltage power supply Open Open contact EOL End Off Life lamp 20
2. The aux settings for temperature The aux settings for relative air humidity 15 The two aux settings can be used to control the heating systems and the humidifiers and dehumidifiers The menu structure is as follows Pre heat Press key to increase temp H l Pre heat 1x set eater aux satpoint to confirm Press key to decrease temp The pre heat function enables you to pre heat a room before the lights come on This is useful for preventing problems relating to condensation etc Night heater Press key to increase temp night heat Press key to decrease temp The pre heat function enables you to control a heater when the lights are off 16 RH AUX Using an optional aux box the controller can humidify or dehumidify during the periods lights on and lights off or always The menu structure is as follows m Press key to Press key for Da increase RH humidify y Press SET to decrease RH dehumidify Therefore you can opt for humidifying or dehumidifying during the periods lights on and lights off or both Advanced VPD menu HT 292 RH 60 2 PT 26 S UFD 1 19 You can read the room temperature AT relative humidity RH plant temperature PT delta T DT and the VPD value on the VPD display screen You can switch between PT and DT by pressing the and keys in this screen PT is the plant temperature measured with the plant temperature camera
3. 14 till 22 06 Countdown The time that the light has to go on or off can be set by pressing the SET key while COUNTDOWN is displayed on the screen Asynchronous times which can reduce a cycle can be set with this parameter Lountdown on off iH 10 hours Rise fall Sunrise and or sunset can be simulated using rise fall The time which indicates how long the simulated sunrise or sunset should last can be set by pressing the SET key while Rise Fall 1s displayed 7 Fall time H minute Temp limit Three temperatures are displayed L H and S When the first temperature L Low Dim is reached the lights dim to prevent the temperature from becoming too high in the room The controller dims the lights up to maximum 35 When the second temperature H High Dim is reached despite the dimmed lights the controller switches off all lights operated by the even ports 2 and 4 Half of the lights are therefore turned off When the third temperature S Shutdown is reached despite the fact that all lights are dimmed and half of the lights are off all lights go off Then there is probably a problem with the air conditioning in the room The temperature limits can be altered by pressing the SET key Teme limit LzH75 ae C432 0 3490 Temp offset The value of the room temperature sensor can be changed adjusted or calibrated by pressing the SET key while TEMP OFFSET is displayed on the screen Use the and ke
4. Delta T indicates the difference between AT and PT The difference between plant temperature and room temperature provides an indication of whether a plant vaporizes or not VPD provides an indication about the vaporization pressure A crop that vaporizes normally is ca 2 degrees cooler than the room temperature The vaporization pressure VPD is usually between 0 6 and 1 5 kPa Pressing the SET key on the VPD display screen will open the menu PT gt AT Dim The crop does not vaporize adequately if the plant temperature is higher than the room temperature The controller can intervene by dimming the lights and turning off the CO2 dosing The difference in temperature can be set by pressing briefly on the SET key and using the and keys to fill in a value A typical value is for example 2 degrees The controller will intervene 1f the leaves of the crop are 2 degrees warmer than the room FTAT start dimm oft 17 PT gt AT shutdown The plant temperature will increase further if the controller has intervened but no measures are taken to restart the vaporization The controller will then shut down the lights completely if the plant temperature rises The difference in temperature in which the controller shuts down all lights can be set in the PT gt AT shutdown option A typical value in which the controller does this is usually 2 degrees higher than in PT gt AT Dim therefore 4 degrees PT SOT shutdown oft PT o
5. AUTO OFF and confirm with SET LUD backlight JH 11 Temperature display Here you can select the temperature display in either Celsius or Fahrenheit Press on the SET key and using the and keys select Fahrenheit or Celsius and confirm with SET Output display You can select to display the status of dim boost in the Light screen in Watt or in percentages Press on the SET key and using the and keys select Watt or percentage and confirm with SET a IETA LFUL disPlay Channel control Up to 40 light fixtures ballasts can be controlled per port 1 2 3 or 4 However ports 3 and 4 can also be used to control a second room including lighting using the slave invert function with a maximum of 80 light fixtures per room Channels 3 and 4 will then switch ON when Channels 1 and 2 switch OFF and vice versa In addition an optional SSR relay can be controlled in order to connect another type of lighting together with the Dimlux light fixtures ballasts By pressing the SET key and using the and keys you can select Normal gt ports 1 2 3 and 4 control all ballasts light fixtures Channels 3 amp 4 invert gt ports 3 and 4 operate contrary to ports 1 and 2 The second temperature sensor that can be connected on the RH T2 port can be used to control two rooms operating in turns The RH function is then not necessary Channels 3 amp 4 relay gt ports 3 and 4 control an SS relay with which a
6. CO2 sensor The sensor can control a CO2 generator or a cold CO2 installation PT camera E AN amp A a The temperature of a crop can be measured using the plant temperature camera This temperature provides an indication of the vaporization of the crop The camera is also needed to determine the VPD 3 The auxbox Auxbox Auxbox fan An auxbox can be connected to controller s aux port The auxbox converts the maxi controller into a fully automatic air conditioning system The auxbox is available in two designs The auxbox has two connections one for a heating system heater and two for a humidifier or dehumidifier The other design can also control a fan as well as a heating system and a humidifier and a dehumidifier The fan control is electronic and has no annoying buzz Connecting the lighting The controller communicates with the Dimlux ballasts or the light fixtures by means of a signal cable which should be connected between the controller and the various ballasts or light fixtures The best signal cable is e g a 0 5 mm2 double core duo coloured cable This is to prevent connection errors such as mixing up the plus and min core A green plug with 1 2 3 and 4 indications is located at the side of the controller These are the four channels to which up to 40 light fixtures can be connected to each channel Two min connections are also available The controller is connected with the light fixture ballast b
7. or key which light fixture you wish to control 315 Watt CDM lamp 400 Watt HPS or HPI 600 Watt HPS not EL also called a 230 V lamp 600 Watt EL UHF HPS EL UHP also called a 400 V lamp 630 Watt DUAL 2 x 315 Watt CDM 1000 Watt EL UHF Also called a 1000 Watt double ended Basic CO2 menu If you press the SET key in the CO2 screen you can calibrate the sensor automatically By pressing the SET key again you can select Auto Calibrate Yes or No If you want to calibrate the sensor it should be placed in outdoor air for five minutes and then press Auto Calibrate Yes auto calibra Basic aux fan menu The following parameters can be set in the basic fan menu Fan mode Temperature Press SET to change these parameters Fan mode can be used to choose between the following options Temperature gt the fan works faster if a certain temperature is reached Temp day dehumidify night gt the fan works faster if a certain temperature is reached during the day and during the night if a certain relative humidity is reached Dehumidify day night gt the fan works faster if a certain relative air humidity is reached Various values can be set for day and night The temperature mode can be used to set the temperature at which the fan must work faster Advanced Numerous parameters can be adjusted or set in the advanced menu Advanced keys OFF MODE By pressing briefly and repeatedly on the OFF MODE key you
8. Dimlux maxi controller EVO1 1 1 Datalog Contents Introduction Pag 2 Components Pag 2 4 Connecting the lighting Pag 4 Connecting the CO2 Pag 5 Connecting aux fan Pag 5 Connecting the VPD Pag 5 Basic advanced menu Pag 6 Basic keys Pag 6 Basic light Pag 7 Basic CO2 Pag 7 Basic aux pag 8 Advanced Pag 8 Advanced keys Pag 8 Advanced light Pag 8 11 Advanced CO2 Pag 12 14 Advanced aux Pag 15 17 Advanced VPD Pag 17 18 Advanced high low log Pag 18 19 Advanced error alarm log Pag 19 Symbols on the controller Pag 19 Datalog Pag 20 Introduction The Dimlux maxi controller is a modular control system for operating and monitoring the Dimlux lighting CO2 and VPD The EVO controller is available with and without USB log function The controller also has a thermostat hygrostat function AUX and can also control a fan A maximum of 160 Dimlux light fixtures or pre selector devices can be controlled by means of four channels The controller switches the lighting on or off by means of a built in timer If a set temperature 1s exceeded the lighting dims automatically or if necessary switches off half or all light fixtures off A switchboard with timer relay reducers is not necessary Besides lighting the controller can also regulate the CO2 level in an air conditioned room A very accurate dual beam CO2 sensor can be used to control CO2 generators cold CO2 installations and ventilation sy
9. can select Lights permanent off gt light is always off Lights permanent on gt light is always on Lights by timer gt light goes on off via the timer Lights by countdown gt light goes on off by countdown asynchronous times e g 10 10 or 11 11 Lights control as slave invert gt 1f you use two rooms and two maxi controllers two or more maxi controllers can communicate with each other by means of a connection between ports B gt B and C gt C on the controllers A double core cable should then be placed between these two ports If slave invert is selected the light in room 1 for example switches off when the light in room 2 goes on and vice versa The slave controller copies the date time timer countdown and rise fall of the master controller Lights control as slave copy gt this function is similar to the previous function except that now the light in room 2 operates at the same time as the light in room 1 Several controllers using different slave settings can be connected in this manner e g 2 slave invert and 3 slave copy If several rooms are used simultaneously the clock runs the same time everywhere 8 ESCAPE By pressing briefly and repeatedly on this key you can select LIGHT The room temperature light output and remaining and current time are displayed CO2 The current and set CO2 value are displayed Aux fan menu The set fan speed and temperature air humidity are displayed VPD Th
10. e displayed The high low values can be reset by pressing the SET key in this screen and by using the and keys to select Reset gt Yes The high low values are overwritten every 24 hours Error Events The error events screen shows the date and time that an event or error has occurred Here you can read for example whether dimming was carried out because the temperature was exceeded The log can store up to 10 events errors If the log is full the first entry is overwritten Pressing the SET key will erase the event error log If the message PSU V appears the controller is connected to an adapter with the incorrect voltage The voltage must be 16 volts Use the original adapter Symbols on the controller Main screen light CO2 screen sensor not present CO2 dosing or heating normal off X CO2 Off due lamps off normal on CO2 sensor not present L low dim temp control J Co2 sensor jammed H high dim temp control P Co2 off due PT S shut down overheat CO2 normal off P Temp control PT plant temperature 1l MH4 gas alarm fire toxic X Shut down overheat PT plant temperature 2 CO carbon monoxide alarm toxic 19 DATALOG only EVO 1 1 datalog The EVO DATALOG can be used together with a USB data stick to store all values measured by the controller in order to view these later in graphic form on a PC The controller writes the values o
11. e plant temperature room temperature relative humidity and the VPD are displayed High low records All high low values of the connected sensors are displayed here Using the and keys the values of the different sensors can be displayed including when the maximum minimum event has occurred Events alarm log Here you can see when and why the controller has intervened PLUS key You can browse or increase the values by pressing this key briefly and repeatedly MIN key You can browse or decrease the values by pressing this key briefly and repeatedly SET key Using this key the menu is opened in order to change settings Advanced light menu The menu will open by pressing the SET key while the Light screen is displayed Using the and keys you can navigate through the various parameters in the menu The following parameters can be set in the Light menu Time The current time can be set by pressing the SET key while TIME is displayed on the screen For this purpose use the and keys and confirm with SET we tele Date The current date can be set by pressing SET if DATE is displayed on the screen For this purpose use the and keys and confirm with SET Soon Timer ON OFF The precise time that the light has to go on or off can be set by pressing the SET key while TIMER is displayed on the screen For this purpose use the and keys and confirm with SET Timer on off
12. ffset Here you can adjust any deviation in the display of the temperature measured by the plant temperature PT camera Since the controller intervenes in case of relatively small temperature differences it is important that the room temperature indicates the same value as the plant temperature camera You can check whether the values correspond by hanging a sheet of paper in the shade of the room You can check whether there is a difference in the room temperature and the PT camera by directing the PT camera toward the sheet of paper after approx 20 minutes The sheet of paper adopts the temperature of the room You can adjust the value by pressing briefly on the SET key and using the and keys FT offset F H 6 C RH offset The sensor that measures the RH in the room can also be calibrated Press the SET key and use the and keys to adjust the value High low Here all high low values of all connected sensors are displayed By using the and keys the values of the different sensors can be displayed including when the maximum minimum event has occurred AT high low The highest and lowest room temperature including the time are displayed 18 RH high low The highest and lowest RH value including the time are displayed PT high low The highest and lowest plant temperature including the time are displayed CO2 high low The highest and lowest CO2 value including the time ar
13. ible Temperature RH Day RH Night Max fan speed Day Max fan speed Night Min fan speed The aux setting Heat The aux setting RH Press SET once and use the and keys to select the above options Press SET once more to change these parameters The fan mode can be changed by pressing the SET key twice The fan mode determines when the fan control becomes active It is possible to choose between the following options Temperature gt the fan works faster if a preset temperature is reached Temp day dehumidify night gt the fan works faster if a preset temperature is reached during the day and during the night if a preset relative humidity is reached Dehumidify day night gt the fan works faster if a preset relative humidity is reached A different value can be set for the day than for the night Manual gt the fan is set manually to a set speed The temperature mode can be used to set the temperature at which the fan must work faster The RH day mode can be used to set the maximum humidity during the day The RH night mode can be used to set the maximum humidity during the night Max speed day can be used to set the maximum fan speed during the day Max speed night can be used to set the maximum fan speed during the night The min speed mode can be used to set the minimum fan speed Some fans or ventilators cannot be dimmed by more than 30 Always check for a draught and whether the fan is working
14. ly and repeatedly on this key you can select LIGHT The current time room temperature light output and remaining time are displayed CO2 The current and set CO2 value are displayed AUX FAN The current temperature and the set fan speed are displayed VPD The plant temperature room temperature relative humidity and the VPD are displayed Using the ESCAPE key will also enable you to leave the menu PLUS 4 You can browse or increase the values by pressing this key briefly and repeatedly MIN You can browse or decrease the values by pressing this key briefly and repeatedly SET Using this key the menu is opened in order to change settings Basic light menu The following parameters can be set in the basic light menu Current time Timer ON OFF Type of ballast light fixture Time Press the SET key briefly the current time will appear By pressing the SET key again the time can be set using the or key Pressing the ESCAPE key will return you to the Home screen Timer ON OFF Press the SET key shortly and navigate through the menu using the or key until Timer ON OFF appears on the screen Pressing the SET key again will allow you to set the ON and OFF times Type of ballast light fixture Press the SET key briefly and navigate through the menu using the or key until output power appears on the screen By pressing the SET key again you can select by using the
15. n and dosing of CO2 tart dosing tim H minutes Stop dosing time SLOP dosit 19 Mane H minute To deal with gas CO2 more efficiently you can opt for stopping the CO2 dosing before the lights go off You can select the interval in minutes between stopping the CO2 dosing and lights off by pressing the SET key 13 CO 2 dose time The heater must burn for at least four seconds to guarantee complete burning of the gas when using a CO2 generator In practice you might observe that the gas does not burn well below this minimum value In that case the generator switches on off oscillates quickly possibly resulting in the release of toxic gases The minimum dose period can be changed by pressing the SET key The dose period can be set to a minimum in case of using cold CO2 For heaters we advise up to 10 m2 6 sec 10 16 m2 12sec 16 24 m2 18sec over 24 m2 24sec COSY dosetlime h seconds CO2 night heater A room can also be heated by the CO2 generator if the power supply is limited The night temperature can be set by pressing the SET key Attention Ensure sufficient supply of fresh air to the room Poor burning can cause the release of toxic gases that are harmful to people animals and plants The flame must always burn with a blue colour 14 Advanced aux fan menu Eight parameters can be set in the advanced fan menu in order to ensure that the installation works as efficiently as poss
16. nother type of lamp can be connected mais t eX Press briefly on the SET key in the CO2 display screen to open the CO2 menu Use the and keys to navigate through this menu Auto calibrate The auto calibrate function sets the value automatically to 400 ppm if the sensor is located in outdoor air Put the sensor for five minutes in outdoor air press on the SET key and select auto Calibrate Yes or No and confirm with SET 12 Manual calibrate You can also select to calibrate the sensor manually Pressing briefly on the SET key will open the menu Press the SET key once more when CO2 calibrate is displayed Here you can adjust the value If the sensor indicates 440 ppm for example in outdoor air you calibrate the sensor by filling in 40 ppm using the and keys Us manual calib J FFM CO2 mode You can opt to add or remove CO2 air quality in living accommodation CO2 Addition is selected if CO2 needs to be added CO2 Removal is selected if CO2 needs to be removed CO2 smartlogic If the CO2 smartlogic function is on a special algorithm is used to keep the CO2 value as stable as possible If this function is off the controller doses CO2 until the set value is reached Start dosing time To deal with gas CO2 more efficiently you can opt for dosing the CO2 after the lights come on By pressing the SET key and using the and keys you can select the interval in minutes between lights o
17. nto the stick every minute Press the OFF MODE key for four seconds to start the log The message initializing USB stick appears on the screen The 400 Watt lamp flashes once a minute to indicate that data are being written to the disk Press the OFF MODE key once more for four seconds to stop the log The message stop logger appears on the screen If the message Fatal USB error appears on the screen the stick provided is probably not being sued or the stick must be formatted Filter 1 Project testweekend zonder fluctuatie v Y Omgevingstemperatuur a Ingestelde limiet low GB EN V Planttemperatuur Ingestelde limiet high GB m eH HH WP ee ef Dag 25 01 15 v ym 260115 vl S Pere E Ong imiethig noma a oP Luchtvochtigheid Ingestelde limiet shutdown E Tijd 00 00 v tim 23 59 v M Verdampings druk E V C02 setpoint B M CO2 concentratie Jf Project Actualiseren L Verlichting Vergelijken Luchtvochtigheid amp BS Lak F i a ee ee lt n TL N ww e amp Ww s3838 888 mp oo 3 Tijd LED indication on Dimlux ballasts The ballast of Dimlux has its own self diagnosis system Using a red and green LED on the ballast or fixture An error or the status can be read On LED on Off LED off Strobo very fast flash Flash normal blink
18. sor and PT camera should be connected to the controller Both the temperature sensor and the RH sensor should be covered against the incidence of light A cardboard cover is sufficient The PT camera should be mounted in such a way that it illuminates the crop under an angle of approx 45 without measuring walls reflectors or other parts of the room as well A circle with a diameter of 50 cm is measured 1f the distance to the crop is 50 cm The circle is 80 cm 1f the distance is 80 cm Basic advanced menu JS1ng HaVanced ment The controller has a basic and an advanced menu This enables a very easy operation without the need to go through the parameters that were set earlier The basic menu only shows the most frequently used functions All parameters can be changed and set in the advanced menu You can switch between the basic and the advanced menus by holding down the SET key Basic keys OFF MODE By pressing briefly and repeatedly on this key you can select Lights permanent off gt light always off Lights permanent on gt lights are always on Lights by timer ON OFF gt lights go ON OFF using the timer There are also two shortcut keys available When you press the MODE key first and then the MIN key the Lights permanent off starts to operate immediately If you press the PLUS key after the MODE key the Lights permanent on starts to operate immediately ESCAPE By pressing brief
19. stems for air replacement On the AUX port of the EVO 1 1 an auxbox can be used to connect a humidifier or a dehumidifier a heating system and even a ventilator Various parameters can be read and regulated in a VPD environment The screen shows the ambient temperature relative humidity plant temperature and VPD The DATALOG function can be used to store all values on a USB stick The controller writes all measured values onto the stick every minute and these can be read off later in graphic form on a PC only EVO 1 1 Datalog version The controller can also operate the lighting in two rooms in turns This requires a second temperature sensor which can be connected to port RH T2 The relative humidity sensor will no longer be required The controller is modular All sensors can be purchased independently according to need Components The controller The controller regulates and operates the lighting CO2 VPD status and any other connected components AUX Temperature sensor The temperature sensor measures the room temperature and should be protected against light shaded A cardboard cover is sufficient RH sensor The RH sensor measures the relative humidity in the room This is necessary to determine the VPD or to control a humidifier or a dehumidifier The RH sensor should also hang in the shade CO2 sensor You can read and control the current CO2 level in a room using a very accurate dual beam
20. y means of a double core cable You select channel 1 for example and a min terminal on the controller Connect these with the and on the light fixture ballast If there is more than one ballast light fixture the double core cable can be looped in series from the first ballast light fixture to the next one Every time to and to up to 40 ballasts light fixtures per channel If an installation has several light fixtures ballasts these should always be equally divided over two channels These should preferably be channel 1 and 2 In the event of a high temperature protection channels 2 and 4 break down A temperature sensor should also be connected to the controller on the temp channel If this is not done the temperature protection 1s not active and a appears on the display Connecting the CO2 The dual beam CO2 sensor can simply be plugged into a wall socket The long cable including the plug is inserted into the port with the CO2 indication Now you can connect the CO2 generator or pressure reducing valve to the CO2 sensor Connecting the auxbox The auxbox is easily connected to an existing wall socket The long cable is connected to the aux port via the plug Now the components for controlling the box must be inserted into the correct port S Aux box Maxi controller Dehumidifier Connecting the VPD To be able to determine the VPD value the temperature sensor RH sen
21. ys for this Test and confirm with SET Output power You can select which light fixture ballast must be controlled by pressing the SET key while OUTPUT POWER is displayed on the screen Using the or key you can select 315 Watt CDM 400 Watt 600 Watt 600 Watt EL UHF 630 Watt DUAL CDM 1000 Watt EL UHF Select the correct filling ballast output and confirm with SET OULPUL Power s TTT a Say ag 2 saa ate PED je ss e a E m g s3 ern Bs s se i he se Gi a Sa 88 2 a ame ae id ae ou rar Half force mode Switching the half force mode to ON will switch off half of all lights ports 2 and 4 This might be required if the ballasts are dimmed but still radiate too much light It can also be used to prevent overloading the power supply when the lights burning in several rooms overlap each other temporarily Use the and keys and confirm with SET Halfforce mode JFF After power failure In case of a power failure you can opt for leaving the lights off or for switching the lights back on after the power supply has been restored Using the and keys opt for CONTINUE or HOLD and confirm with SET Hfter PFowerfail Continue LCD backlight By pressing the SET key while LCD backlight is displayed on the screen you can opt to have the LCD screen displayed continuously or to switch it on only when a key is pressed Using the and keys opt for always ON or