Home

Manual GS-TH

image

Contents

1. 2 Combined temperature and humidity sensor and CO2 sensor measurement Composite measurement can be done by using the branch adapter for GS GS DPA and the CO2 sensor GS CO2 each sold separately A WARNING If the CO2 sensor GS CO2 is included in the assembly it cannot be powered with batteries CO2 Sensor GS CO2 Temperature and humidity sensor GS TH Branch adapter for GS GS DPA Qnumeenmen The GI100 s power is provided through a USB cable connection GL100 main module 1 Screen display menu flow After connecting the power supply connect this module and operate it in accordance with the content displayed on the screen Refer to 2 How To Measure above and the USER S MANUAL for the CO sensor 2 Free running screen STOP ALM 1 28 TEMP 26 16 Hold down the QUIT key approx three seconds to HUM 37 3 put the module into standby state DEWP 10 Press the ENTER key while in standby state to return to the free running screen lt Extension cable gt The module can be used approx 1 5 m away from the GL100 by using an extension cable for GS GS EXC However you cannot connect and use multiple extension cables CAUTION It is not possible to be used by connecting two same sensors GRAPHTEC August 1 2014 Zz ALTHEN
2. approximate 15 x 45 x 10 2 mm not including protruding parts Weight approximate 14g We recommend replacing the module periodically ALTHEN GmbH Me und Sensortechnik Frankfurter Stra e 150 152 65779 Kelkheim Tel 49 0 6195 70 060 Fax 49 0 6195 70 0666 info althen de althen de 6 Combined Measurement 1 Combined temperature and humidity sensor and illumination ultraviolet sensor measurement Composite measurement can be done by using the branch adapter for GS GS DPA and the illumination ultraviolet sensor GS LXUV each sold separately Illumination Temperature and Ultraviolet sensor o humidity sensor GS LXUV GS TH a i Hin r ias Branch adapter for GS GS DPA enonnanenm GL100 main module 1 Screen display menu flow After connecting the power supply connect this module and operate it in accordance with the content displayed on the screen Refer to 2 How To Measure above and the USER S MANUAL for the illumination ultraviolet sensor 2 Free running screen Hold down the QUIT key approx three seconds to TEM e s 26 160 put the module into standby state HUM 37 3 x P 440x When running on batteries the module will 0 0 automatically go into standby state after three 3 r z i minutes of no operation Press the ENTER key while in standby state to return to the free running screen
3. can be 39 8 switched to the elapsed time with the QUIT key when recording Sampling interval SD is displayed during accessing the SD card LAN displayed when the wireless LAN connection is enabled You can switch to the Accumulation screen with the ard k ys when recording data The module s status is shown with the lamp display STATUS Orange Accessing SD card Access light Low battery Flash once every 5 seconds Alarm active Flash once every 10 seconds POWER Green Power supplying Flash once every 10 seconds Wireless LAN connection Flash once every 5 seconds possible status A CAUTION e When accessing an SD card do not remove the SD card The data may not write properly or the SD card may be damaged e When low battery is displayed replace the battery or connect the USB interface to supply power as soon as possible Caution Batteries cannot be replaced when recording data Replace them after the recording has finished 2 Recording completion Press the START STOP key to stop measuring The screen display will change to the standby screen display ENTER key to start Press ENTER key to change to the free running screen display GL100 TH Sleeping QUIT key to Power Off BAT LAN 4 How To Confirm The Data Check the recorded data with the application software included with this module using the method below for details refer to
4. GRAPHTEC GS TH UM 151 2 Messung G S TH For GL100 1 Power supply Refer to Quick Start Guide or USER S MANUAL Connect this module while power is being supplied to the GL100 by a battery or USB cable 2 Start up and operation 1 Screen display menu flow After power on the GL100 is ready for operation by holding down MENU key USER S MAN UAL When the module is connected Module Type Recognition screen is displayed When the module is not connected Module Unconnected State screen is displayed Operate in accordance with the displayed instructions Temperature Humidity Sensor Thank you very much for buying this GRAPHTEC product SENSOR ERROR Module unconnected state Please connect e sensor A lt Operation gt eee Connect the module This product is a measurement sensor hereafter module that connects to the GL100 N GL100 WL These directions describe preparations and cautions before Recognition of module types measurement Please wait To ensure safety please read the operation instructions etc GL100 TH For details on the warnings and how to handle this module please read Quick Start Guide or USER S MANUAL included on the CD ROM included in the GL100 packaging Standby state key to start lt Operation gt Press ENTER key Module start up GL100 TH Initializing Confirmations ot the exterior After opening the package plea
5. MP setting The accumulated temperature can be set for the set temperature AMP Input setting Mode REF TEMP 1REF TEMPV ive GY Mode PREF TEMP REF TEMP REF TEMP Value setting 3 Cable packing 3 DATA setting GL100 Set the Sampling and Capture Mode those will be recorded to the data TL Hokk portion ssssssssssisscessceecs Used to mount to a wall recording media 2 COMMECEON sisii Used to connect to the connector on the The recorded data s size will be displayed in the information for the SD card GL100 module being recorded to Please take note of it DATA recording condition setting Sampling 500 ms 1 2 5 10 20 30 s 1 2 5 10 20 30 60min 3 Cable packinge This packing is used when connecting the connector HO AT Al 279 Sampling 1sV Capture MODE CONT V ZA CAUTION Attaching just this module wali mounting e oe to the wall etc will damage hook the connector cable Always connect to the Capture MODE CONT 1 Hour 24 Hour Capture DIST Memory SD card GL100 4 TRIGGER setting Select the conditions for beginning data recording after measurement starts Off Pressing the START STOP key on this module will start stop recording A CAUTION The temperature sensor measures the change in capacitance Start The recording will start with the trigger source conditions after of the conductivity caused by moisture absorption pressi
6. ng the START STOP key Therefore dust fumes and other organic compound may The recording will stop after pressing the START STOP key affect measurements Usage in an environment with a large quantity of these substances floating about will cause large measurement deviations Stop The recording will start after pressing the START STOP key and will be stopped with the trigger source conditions reicceal 3 9 TRIGGER capture condition settings TRIG Setting OffV gt TRIG Source O0ffV TRIG setting Off Start Stop TRIG Source After connecting the GL100 to modules or sensors please always check set the time and date Date Time ALTHEN 5 ALARM setting Set the alarm information Please set the number level A Mi Alarm Of tV 4 9 ALARM settings Value setting 6 Temperature Unit Setting On the OTHER 2 screen you can switch the temperature setting between Celsius and Fahrenheit 3 Aufzeichnung 1 Recording Press the START STOP key to start measuring with the set conditions After pressing START key when the module is in awaiting recording start ARMED is displayed When battery replacement is required BAT is displayed and then when recording is started REC is displayed ee When alarm occurs ALM is displayed N EE Current time 26 7 Note The current time display
7. se confirm that there are no problems scratches and dirt on the exterior before use 2 Free running screen Hold down the QUIT key approx three seconds to put the module into standby state When running on batteries the module will Confirmation of the attached items User s manual this book 1 automatically go into standby state after three minutes of no operation Press the ENTER key while in standby state to return to the free running screen If by any chance faults are found please contact the store where you bought the item 3 Setting 1 Screen operation Please note that items mentioned in this book may change without prior notice Item selecting screen Press the MENU key on the free running screen to go to the setting screen lt How to set gt Select the item with the directional keys Av lt p and press the ENTER key DATA Sampling Capture MODE CONT V ar ames Capture Dest SD Cardy Free CAPA 498180 If the submenu shows f then there are selections in those directions Numbers can be inputted by increasing or decreasing the value with the vand keys This section describes the name and function of each part Numerical entry sereen 1 Hook portion lt How to set gt Date Time 779 Type YY MM DDV Date 20 01 04 Time 03 18 26 anaue 2 Connector 2 A
8. the USER S MANUAL 1 Connect the USB interface and check the online data 2 Insert the SD card into PC and check the data directly 3 Check the data directly from PC via wireless LAN 5 Technische Daten Item Contents Measurement data Temperature humidity dew point temperature calculated value accumulated temperature The accumulated temperature is displayed only when recording Measurement system C MOS Sensor Measurement temperature range 20 C to 85 C Measured temperature accuracy 20 lt TS lt 0 408 C 0 lt TS lt 60 05 C 60 lt TS lt 85 08 C Measurement humidity range 0 0 to 100 0 RH Measured humidity accuracy 25 C O lt RH lt 10 10 10 lt RH lt 20 48 20 lt RH lt 80 5 80 lt RH lt 90 8 90 lt RH lt 100 10 Response time Temperature and humidity 100 sec 63 response 25 C Air flow rate 1 m s The sensor s responsiveness is affected by the measured temperature and air flow rate Sampling interval 0 5 1 2 5 10 20 30 sec 1 2 5 10 20 30 60 min Alarm OFF Level Waterproof treatment Sensor unit With waterproof filter Temperature unit Select from C Celsius F Fahrenheit Usage environment Within the measurement range of temperature and humidity However set it to the environment if the GI100 and this sensor are in the same environment External dimensions WxDxH