COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT600i
Contents
1. ENTRY DELAY VALUE 0 255 000 There is no Videofied Exit Delay with the From the Host option Videofied will only control the Entry Delay Enter the value for your Entry Delay up to 255 seconds and press Y YES YyEs TRANSMISSION DELAY Value 0 600 O00 By entering a value using the keypad up to 600 seconds the transmission of any event will be delayed that many seconds Enter the value you would like for the Transmission Delay and press yrs yes ARMING CONFIRMATION Value 0 5 0 5 Arming Confirmation is the number of seconds of latched voltage where voltage must stayed latched after the panel will require before arming Enter the value you would like for the Arming Confirmation and press Yyrs Yyrs 9 Page RSIY IDEO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS GERS ves PARAMETERS APN CODE Y YES PENECODEE XXXXX XXXXXX XXX Your APN code Access Point Name is given to you by your Cellular Provider Press Y YES to enter into the parameter and use the Keypad to complete the code Press Y YES to confirm your entry and the arrow to move to the next parameter Your USERNAME is given to you by your Cellular Provider Press Y YES to enter into the parameter and use the Keypad to complete the name Press Y YES to confirm your entry and the gt
2. need an entry exit delay should be set to AREA 1 Devices that must be instant trigger should be AREA 2 Press YES FUNCTIONAL DEVICE TE T ENTERING A NEW DEVICE Yves or ESC NO Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is OPERATION off COMPLETED Other XT setup with CMA600 keypad Standalone ONLY Press YES on Radio Range Test You must allow the Radio Range test to run for at least 30 seconds 9 9 before RADIO ae stopping the test by pressing YES TEST Other setup badges codes arming profiles etc must be set with the CMA keypad GPRS error codes Typographical error in the APN Code username password or a provisioning problem SIM card not detected not inserted SIM card not activated GPRS Level Test No GPRS Signal Event Log No Error Found lllPage RSIV2E9 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS Entering a Badge or Access Code for Arming Disarming After Initial programming has been completed you are not able to arm and disarm the system until you enter a user code or badge the installer code cannot arm and disarm the system Codes can be 4 6 digits and the 4 digit must be 2 values higher or lower than any other code on the system Example User code 1234 next code cannot be 1235 1236 1233 or 1232 These are reserved for Silent Duress and Audibl
3. Voltage ii on oiin Sein VIN 9V VIN 15V When using an external hardwired device that is powered the ground negative wire must be hooked up here When using a dry contact one wire must be hooked up here to use Videofied to power the input When using the inputs the panel must be powered by 4 Alkaline D cell batteries and a 12v DC power supply The powere sup ply mus t be hooked up to these terminals 20 Page RSI 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110
4. arrow to move to the next parameter USERNAME XXXXXXXXXXX Your PASSWORD is given to you by your Cellular Provider Press Y YES to enter into the parameter and use the Keypad to complete the name Press Y YES to confirm your entry and the gt arrow to move to the next parameter PASSWORD XXXXXXXXXXXX D gt Your IP1 address is given to you by your Central Station Press Y YES to enter into the parameter and use the Keypad to complete the address Press Y YES to confirm your entry and the gt arrow to move to the next parameter You will use either a IP address or a Domain Name but not both TPP ADDR ees MXM MXM MXM XXX Your Domain Name is given to you by your Central Station DOMAIN NAME 1 Press Y YES to enter into the parameter and use the Keypad to complete the name Press Y YES to confirm your entry and the gt arrow to move to the next parameter You will use either a IP address or a Domain Name but not both leave it blank if an IP has already been entered gt The Port is given to you by your Central Station By default Pyrs the panel will use 888 If you need to modify the port press DOMAIN NAME 1 XXXXX XXX XXX the Y YES key to enter into the parameter and the keypad PORT 1 to complete the port Press Y YES to confirm and the gt arrow to move to the next parameter The Port is given to you by your Central Station By default the panel will use 888 If you need to m
5. gt to set the Hour Use the on or gt to set the Minutes YOU MUST ALWAY CHOOSE YES Use the Alphanumeric Keypad to enter in a 4 8 digit account number provided by the Central Station Other periods are available 48 hours 24 hours 12 hours 1 hour No Test Use arrows for the selection and press Y YES to confirm We suggest at least a 24 hour test O or for period selection VyEsS to apply Using the arrow keys Yves to choose the Hour and Minute the periodic test will happen 7 Page RSIVIREO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS CODE STATE modification These are the default transmitted events Intrusions Panic Periodic Test Tamper Supervision Fault Device Battery Low Panel Battery Low CODE spaATE MODIFICATION 2 If you would like any other events to be transmitted press yes and use the om or gt to toggle between events TRANS STATE MODIFICATION bist cor lll events L If you would like the default press ESC NO CONFIGURATION Use the Alphanumeric Keypad to name the area and press Y YES Repeat for all areas If you want to keep the default area names press the ESC NO key ARMING OPTION You will choose between configurations depending on how you will be arming the system From the host Will make the XT a piggyback xtender system that arms and disarms off the
6. lt j TECHNOLOGIES COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT600i XTX600 GPRS PANEL A Videofied CMA601 Alphanumeric Keypad or Frontel TMTi is required for programming and maintenance CMA601 4455 White Bear Parkway B ROT RF ROLOGIES White Bear Lake MN 55110 877 206 5800 2009 06 15 Ed1 0 User manual for XT600iGPRS 1 2 3 4 5 6 7 8 9 Bas c Setup Guidelines for Installation and Programming SETUP AND PROGRAM Obtain the account number from the Central Station Activate the SIM card by calling your SIM card provider Note Do step 1 and 2 the day before the install Setup and program the system in the office or in your vehicle DO NOT MOUNT THE DEVICES Add user codes and or badges after initial programming Silence the siren before you set the alarm Arm the system and send one alarm signal and video to the central station Call the central station and make sure they received the signal DEPLOYING THE SYSTEM ON SITE Put the panel where you want to mount it and run the GPRS test to make sure you are receiving good cell signal If you get 3 5 or better mount the panel If not you will need to move the panel and run the test again Now you are ready to deploy the devices Use your keypad to run the RF test for each device If you get a 9 9 for your RF test on the first device then mount it If not you will need to move the device to get optimal signal Note If you are not
7. manual for XT600iGPRS 7 How to test GPRS signal and mount the control panel Before the system is mounted you will need to check the GPRS level to make sure it is adequate If the level is 3 5 or better you can mount the control panel in that location Press the gt arrow to move to MAINTENANCE DISARMED LVL 3 YyEs MAINTENANCE Press the arrow to move to GPRS LEVEL Press YES on GPRS LEVEL to start the test This test can take up to 5 minutes to complete Pressing the YES ESC NO or CLR buttons will prematurely end the test This test will automatically issue the results to the display of TEST IN PROG the keypad when it has completed with either a level out of 5 YES END 0 5 5 5 or an error code listed below Use the arrow keys to keep the keypad away during the test Press and hold ESC NO for 5 seconds to return to the main mani GPRS LEVEL GPRS LEVEL X 5 Codes Error Fix ve Authentication Error Double check and re enter your APN USERNAME and PASSWORD te SIM card not detected Power down the unit and re insert the SIM card Ise SlM card not activated Contact the cellular provider for activation Wey No GPRS signal available Try re locating the panel or checking a online coverage map for the carrier How to Mount the Control Panel Fix the back casing on the wall with 3 screws I5 Page RSE 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User
8. the system GENERAL PARAMETERS Use the gt to move to AAARM MODES PROGRAMMABLE ALARM MODES PROGRAMMABLE Yyrs Use the arrow keys to find the arming profile you would like to FULLY ARMED configure The letter underneath the area describes which devices will be armed when this profile is used To change you must AREAS 1234 press the corresponding area number to cycle through the f AAAA different letters A All Devices Armed D All Devices Disarmed E Only external devices armed Y P Only perimeter device armed YES ALARM WITHOUT SIREN SIREN All Sounders are triggered during intrusion SILENT No sounders are triggered during intrusion WITHOUT SIREN Only arming device sounders are ves triggered during intrusion DELAY BEEPS Only delay beeps are sounded by the interior siren ACCESS LVL 4 YES BADGE OR CODE x kh oe BADGE OR CODE Use the arrow keys to find the siren type you would like for the chosen profile 13 Page RSIVIPEO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS 6 How to test to the dispatch center Testing to the dispatch is done twice during installation Once while you are programming the system and then again once the installation has been completely finished Although both will use the same steps the initial test will be just confirmation using one device to verify the programming LO T
9. to test the full system to your central station After arming and tripping each device call the central station and verify alarm and video of each device with dispatch Now you are ready to show the customer how to use the system NOTE To insure proper operation of the system you must get 9 9 with each device before mounting 16 Page RSTVIREO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS GPRS Antenna Connection IWARNING Use caution before removing antenna connection Damaged antenna connector is NOT covered under warranty Using needle nose pliers be sure to only grab the connector and pull directly up Arming Input Wiring Diagram HOST SYSTEM i ONION3d JI ONIGNSd QI 39d 17 Page RSIvivEO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 videofied PRODUCT User manual for XT600iGPRS General Configuration Programmable Inputs APPLICATION NOTE Manufactured by RSI Video Technologies The RSI Video Technologies XT600 series control panels can accept up to 3 hard wired peripheral devices These devices can be normally opened or closed wet or dry YOU CAN ONLY USE THE INPUTS WITH ALKALINE POWER SUPPLY The inputs can be programmed to have unique identifica tion name and transmit one of the standard events used by Videofied With these ca
10. 27 Z LOS DISARMED LVL 3 Enter a User code and press YES or present a badge to the NOY E27 TO SS reader o The system will sound the exit delay through the keypad and ARMING THE badae reader SYSTEM Once the delay has expired and the keypad says SYSTEM ARMED put motion in front of a MotionViewer If the MotionViewer is in area 1 you will need to wait for the entry SYSTEM ARMED delay to expire before disarming the system Once the system has gone into alarm enter a User Code followed by YES or present a badge to the reader to disarm The display will tell you that there has been an intrusion since INTRUSION the last time the system was armed Press YES to continue eee After pressing YES the keypad will tell you which device has DEVICE NAME been triggered Press YES to continue AREA SYSTEM ARMED kK KK The system will go back to the main menu automatically but 10 162 7 29 SOE Se will not allow you to move around in programming until the DISARMED LVL 3 system has disconnected from the central station To verify that the system has transmitted you must contact the Dispatch Center and have the account information ready Note Send 1 MotionViewer in at a time and verify with Central Station that they are getting Alarm and Video before tripping another MotionViewer This will save time with the Central Station 14 Page RSIY2E9 i 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User
11. IES White Bear Lake MN 55110 January 2011 DATE TIME DISARMED LVL 3 ACCESS LEVEL 4 CONFIGURATION PROGRAMMABLE INPUT 1 18 Page 2009 06 15 Ed1 0 User manual for XT600iGPRS BS MMMM After choosing which programmable input you will be using you will be required to configure the input for transmission type name and features of the input Press YES on the parameter and use the ARROW KEYS to change the value and press YES Use the ARROW KEYS to move to the next parameter TRANSMISSION DISABLED ENABLED Will transmit the event no matter panel TRANSMISSION status ENABLED DISABLED No transmission will be sent ONLY IF ARMED Will transmit the event only when the system is fully armed ALARM MODE ALARM ALARM Appearance of the event only ALARM END Appearance and restoral of the event ALARM MODE ALARM INPUT TYPE NORMALLY OPEN The INPUT TYPE will depend on whether or not the external wired device you will INPUT TYPE be hooking up to the Input terminal is Open or Closed in its normal non alarm NORMALLY OPEN state EVENT TYPE INTRUSION The Event type determines the event that is sent to the central station when the EVENT TYPE programmable input is triggered INTRUSION INTRUSION Alarm TAMPER Alarm or Alarm End PANIC BUTTON Alarm INCORRECT CODE Alarm DURESS CODE 1 Alarm SUPERVISION Alarm or Alarm End RADIO JAMMING Alarm or Alarm End LOW PANEL BATT Alarm LO
12. W DEVICE BATT Alarm AC POWER MISS Alarm or Alarm End PANEL RESET Alarm SYSTEM ARMED Alarm SYSTEM DISARMED Alarm PERIODIC TEST Alarm ALARM CANCEL Alarm SMOKE DETECTION Alarm PHONELINE MISS Alarm TMT REQUEST Alarm 19 Page RSIvivEO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS eee ees see SS SS ee INPUT NAME is the name that the Central Station will see when this input is triggered This should describe the function of the device hooked up to the INPUT NAME SIREN MODE SIREN This will determine how the siren will function when the programmable input is activated SIREN MODE SIREN Activation of all sirens on the system SIREN WITHOUT SIREN Only Keypad and Badge Reader sounders SILENT No activation of any sounders or sirens DELAY BEEPS Sounding of delay beeps then full siren MAPPING DISABLED This is a1 to1 relationship between a MotionViewer and the programmable input When the programmable input is triggered it will force the chosen MotionViewer to take a 10 second Video no matter the current status of the MotionViewer We suggest that this is only used when using the CAMERA 1 event types INTRUSION and PANIC or the video will not auto download at the Central Monitoring Station MAPPING votage 9 2 15 vocorvac ow 22 22 7 A REF v Piles Signal current en e a e Voltage uja js j w
13. e Duress The XT system can accept up to 19 Badges or Access codes in any combination Press the arrow to move to BADGES ACCESS CODES DISARMED LVL 3 BADGES ACCESS CODES BADGE OR CODE YES kkk ENTER A BADGE CODE PYES BADGE OR CODE kK Yyrs Enter a 4 6 digit user code or present a badge to the reader for 2 seconds Confirm the code by re entering CONFIRM THE CODE Yves Use the keypad to name the badge or code or leave it blank CODE NAME NAME OF BADGE for the default name ACCESS Yyrs If you are entering any additional codes press YES If you ENTER A have completed entering Badges and Codes press and hold BADGE CODE ESC NO for 5 seconds to return to the main manu Enter the Installer code Badge Presented yrs I2 Page RSIY2E9 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS Changing Siren Options After initial programming has been completed any sounder on the system will be enabled by default this includes the sounder on the Keypad and Badge Reader While there is no way to disable the sounding of the exit delay you are able to disable the intrusion sound Press the gt arrow to move to ACCESS LVL ING 2 INO BSS DISARMED LVL 3 Use your arrow keys to change the level to 4 Enter the installer code for the system CONFIGURATION Press the gt to move to CONFIGURATION Enter the installer code for
14. getting the right GPRS or RF level you can also add on additional antennas for either signal ONLY ON THE XT600GPRS V6000 GPRS PANELS Once you have everything mounted you are ready to arm the system and set off each device Make sure you stand in front of each MotionViewer for 10 seconds so the central station has some video to look at 10 After you have sent signals to central station call to verify The following pages will go through each one of these steps and if you have any issues you cannot resolve please feel free to call technical support at 1 651 855 7800 EXT 45 1 877 206 5800 EXT 45 or you can reach live support chat and additional technical notes at support videofied com Sleeping mode and Wake up on the CMA601 Most of the time the keypad is in a sleeping mode backlight off This mode is automatic after a 30 seconds of inactivity When you press a button the keypad wakes up The first touch on the pad that wakes it up will not be a registered command and will only wake up the keypad 2 Page 4455 White Bear Parkway Suite 700 White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS SETUP MANUAL FOR XT6001 GPRS PANEL THIS SYSTEM REQUIRES A CMA601 or TMT INSTALLER SOFTWARE FOR PROGRAMMING XT Installation Open the Control Panel Use a 1 screwdriver unscrew the 2 screws holding the panel together 31Page RSIVIREO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear La
15. guages are available by scrolling with arrows ITALIANO NEDERLANDS DEUTSCH CASTELLANO lt LANGUAGE gt SVENSKA PORTUGUES FRANCAIS ENGLISH Press YES for the selected one FS or for language selection Yyrs to apply 5 Page RSIV2E9 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS The Radio Range test must be run during the learn in process in order to ensure proper pairing with the control panel This test is the strength of communication between the device and the control panel The keypad will display a real time range out of 9 for the device that the test is running for To receive the most accurate results you must run the radio range test for at least 30 seconds The RF level test must be 8 9 or better for reliable transmission Wait while the screen changes Use the Alphaumeric Keypad to enter the Installer Code This code Is important to keep track of There is no back door to the system You may name the installer code using the Alohanumeric Keypad If you leave the name blank it will default to ACCESS 1 Wait while the screen changes Use the om or gt to set the Year 6 Page RSIVIREO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS Use the om or gt to set the Month Use the S or to set the Day Use the J or
16. ke MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS The SIM card must NOT be inserted or removed while the panel is powered Install the SIM card Put the SIM card on the plastic lt Take care to respect the right direction Slide it into the connector How to Mount the Control Panel Fix the back casing on the wall I gt with 3 screws 0 to Mounting does not have to be performed in order to program the panel Power the XT panel 4 x LSH20 Lithium D Cell 4 x E95VP Alkaline D Cell 12DC power supply Used for Standalone or Xtender mode without Used for Standalone or Xtender mode where Programmable Inputs Programmable Inputs Mapping will be used WARNING DO NOT INSTALL ALKALINE BATTERIES IF INSTALLING AN XTX600 GPRS BELOW 30 F 4 Page RSIY2E9 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS 3 XT Programming Reset the XT Panel Press and hold programming button for 10sec until the Indicator LED blinks twice Press and instantly release the programming button O The indicator LED will blink once The panel is now in Learn Mode for the CMA601 keypad Insert all three batteries into the CMA601 and press on both the ESC NO and CLR keys at the same time and release The indicator LED on the keypad will blink rapidly RS lS 2005 www RsiAlarm com CLR amp ESC NO KEYPAD 1 RECORDED Other lan
17. latching of 9 12v on the arming inputs ARMING OPTION From the host Go to Page 9 if you will be choosing this option ARMING OPTION Standalone Standalone Will make the XT a solo system controlled by arming and disarming using Videofied peripheral devices Other values are available 2 min 1 min 45 sec EXIDE ITAN 45 Sec ENTRY DELAY 15 Sec Go to Page 10 to continue with standalone programming Use the arrows for the selection and yes to confirm Other values are available 2 min 1 min 45 sec 30 sec 15 sec Use the arrows for the selection and yes to confirm 8lPage RSIY2E9 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS Using the control panel as a Xtender system will only be able to arm and disarm by latching 9 12v to one of the two inputs Arming input 1 will control the arming and disarming of devices in areas 1 and 2 Where devices in area 1 are subject to the Entry Delay Arming input 2 will control the arming and disarming of devices in areas 3 and 4 Where devices in area 1 are subject to the Entry Delay ARMING OPTION Y From The Host YES MODE cy MODE Mode Slow Used for following the arming and disarming of Slow Fast the host system This will arm each device one at atime conserving battery life Mode Fast Used to instant arm all devices while sacrificing PYES battery life Yyrs
18. manual for XT600iGPRS 8 Howto RF test for deployment of devices Running the RF test during the mounting of devices is key to a successful Videofied installation This test will ensure that all devices have adequate communication with the control panel All Videofied devices are bi directional which allows the system to ping the device and expect a response The number of successful responses out of 9 will be displayed on the keypad for the device you are running the test for This is also a relative range that will change in real time as you walk further away from the control panel and back closer Press the gt arrow to move to MAINTENANCE DISARMED LVL 3 VyEsS Press the arrow to move to DEVICE LOCATING m Press YES on DEVICE LOCATING to get to the list of DEVICE LOCATING devices Use the arrow keys to find the device you would like to run the test for This test will run as long as you need it to Pressing the YES ESC NO or CLR buttons will end the test This test will show the results on the display of the keypad relative to the number of successful pings to the panel It is required to run the test for at least 30 seconds at the mounting location for accurate results and to have a 9 9 for reliable transmission of alarms and video Press YES when you are finished with the test DEVICE NAME Press and hold ESC NO for 5 seconds to return to the main menu DEVICE NAME Once all devices are checking in at 9 9 you are ready
19. odify the port press ESC NO the Y YES key to enter into the parameter and the keypad to complete the port Press Y YES to confirm and the gt arrow to move to the next parameter Continue through IP2 and TMT IP GPRS PARAMETERS to return to the main menu then ESC NO again to move to ESC NO the next narameter Once you have entered all valid parameters press ESC NO 10 Page RSIY IDEO 4455 White Bear Parkway Suite 700 TECHNOLOGIES White Bear Lake MN 55110 2009 06 15 Ed1 0 User manual for XT600iGPRS 5 or an error Code that will help troubleshoot why it cannot connect To keep the keypad awake use any keys on the keypad except the YES ESC NO and CLR keys This test can take up to 5 minutes Once the level or error has TEST IN PROGRESS posted press YES to continue in programming ve EEND During the GPRS Level test the Modem will boot and GPRS LEVEL Y attempt to gain access to the internet to post a Level out of e For explanation of GPRS errors see bottom of page GPRS LEVEL Videofied will require a 3 5 or better for reliable transmission eS of Video alarms RECORDING DEVICES Each device has a unique programming button Please reference the Installation Sheet for the device you would like PRESS PROGRAM to program PUTTON TOR TDEVICE Device Type Recorded RF TEST x 9 Press ESC NO if first Radio Range Test was successful TEST Use the arrow keys to select the proper area Devices that AREA ALLOCATION
20. pabilities you are able to perform a takeover of an existing alarm system or add in needed devices for the job that Videofied may not manufacture Programmable inputs 1 2 and 3 are triggered by voltage between 9V and 15V and an intesity between 1 5mA 29V and 3mA 15v If a dry contact is used to trigger the program mable inputs the REF output can be used to supply this dry contact During transmission of the programmable inputs alarm the event will be accompanied by zone 26 27 28 respectively Required Products XT600 series control panel CMA601 Alphanumeric keypad Hard wired device with normally open or closed relay Configuration of the programmable inputs can be found at the following menu location With the display showing the date and time stamp along with the current Access Level You must change your Access Level to 4 RIGHT ARROW to ACCESS LEVEL and press YES RIGHT ARROW to ACCESS LVL 4 and press YES When prompted with BADGE OR CODE enter your installer code YES Using the RIGHT ARROW go to CONFIGURATION and press YES when prompted with BADGE OR CODE enter your in Staller code YES With the display showing GENERAL PARAMETERS press the YES key Use the RIGHT ARROW and go to PROGRAMMABLE INPUTS and press YES It will now show you PROGRAMMABLE INPUT 1 Use the RIGHT or LEFT ARROW keys to choose which programmable input you will be using and press YES RSI 4455 White Bear Parkway Suite 700 x4 TECHNOLOG