Home
Silver Mountain Targets Owner & User Manual
Contents
1. 2 Carefully unwind the coaxial cable from around the microphone unit one at a time Mount the microphone on the corresponding colour coded numbered mounting plate attached to the target frame Positioning screws on the back of the microphone fit into holes in the mounting plate ensuring a firm true fit in only the correct mounting plate Silver Mountain Targets Owner 8 User Manual 11 SILVER MOUNTAIN TARGETS 3 Plug the attached cable into the corresponding numbered receptacle located along the right side of the T Mark 600X faceplate gt Repeat these three steps for each microphone unit Note The dual microphone has two cables one for each microphone Make sure that they are plugged into the correct numbered receptacles on the T Mark 600X faceplate Microphone 1 is the one closest to the mounting plate microphone 3 protrudes toward the shooter Note When mounting the dual microphone unit it is critical that the microphones are pointing directly at the shooter The dowels connecting the two microphones should be as close to parallel as possible to the path of the incoming bullets During your initial setup measure this by placing one edge of a piece of wood with parallel edges against the dowels and sighting along the other edge to the firing line as shown below Adjust the mounting plate as necessary Silver Mountain Targets Owner amp User Manual 12 SILVER MOUNTAIN TARGETS Here is an exampl
2. 24 SILVER MOUNTAIN TARGETS Troubleshooting amp Service Troubleshooting Physical Setup Issues Two T Mark 600X Target Controllers with the same IP address cannot be used on the same range at the same time If one of the dimensions mic_width mm or mic_height mm is wrong shots that land in the centre of the target will generate fairly accurate data but the data from shots that are off centre will be very wrong or will not register at all If the AirTemp reading is not accurate to within 1 C 2 F there will be scaling errors in the calculated shot positions If the dual microphone unit is not pointing directly at the shooter there will be scaling errors in the calculated shot positions as well as errors in the measurement of bullet speeds at the target A twisted target frame is acceptable Provided that it is consistent it can be corrected for in the TargetFrame Setup Geometry and Calibration section using the m4z_cal field A target frame that is at a small constant angle 4 5 to the firing line is acceptable and can be corrected for in the TargetFrame Setup Geometry and Calibration section using the targetface angle mils field If your SMT system is set up on a range with fixed frames and your location experiences a deep freeze during Winter you should recalibrate each target frame every Spring after the thaw see p 19 Silver Mountain Targets Owner amp User Manual 25
3. is touch screen optimized but can also be used with a traditional mouse trackpad setup Connect Display Device 1 Power on your device 2 Verify that you are connected to the SMT WiFi network 3 Open your web browser 4 Type in the IP address 192 168 0 48 the same for all S10 Servers to access SMT this displays your customized splash page gt You may want to bookmark this address for future use At present multiple servers on the same range are not supported by the equipment as shipped Contact your local Silver Mountain Targets dealer to inquire about custom configurations Software Setup On your customized splash page you will see a welcome message the SMT logo a prompt to the range officer to Choose targetfaces and a button labelled ADMIN TOOLS Access the Administration Page 1 Tap or click the ADMIN TOOLS button RANGE OFFICER C 2 Type in the password becareful the same for all S10 Servers 3 Tap or click OK gt This takes you to the ADMIN functions page Silver Mountain Targets Owner amp User Manual 15 SILVER MOUNTAIN TARGETS The first thing you must do on the ADMIN functions page is scroll down to the TargetFrame Setup Geometry and Calibration section and set up a new TargetFrame to correspond with each physical target frame to which you have attached a T Mark 600X Target Controller TargetFrame Setup Geometry and Cal
4. the microphones and the target face changes 1 gt 2 3 From the splash page tap or click the ADMIN TOOLS button This takes you to the ADMIN functions page Scroll down to the TargetFrame Setup Geometry and Calibration section Select the TargetFrame you are going to calibrate by tapping or clicking on the corresponding button directly below the section title Scroll down to the Shot calibration worksheet near the bottom of the page gt Confirm that the Target datalink is showing lt Ready gt Shot calibration worksheet Most recent shot Measured shot position INEW x_cal y_cal gt Y APPLY amp SAVE these new calibration values Fire a shot and confirm that its coordinates have been automatically recorded in the Most recent shot fields Travel down range and inspect the target face to locate your shot measuring and recording its actual x and y position in millimetres Then travel back up range Positive x values indicate right of centre and negative x values left of centre Likewise positive y values indicate above centre and negative y values below centre Type the actual x and y position mm of your shot into the corresponding fields of the Measured shot position section of the worksheet Tap or click the APPLY 8 SAVE these new calibration values button this creates fixed x_cal and y_c
5. web browsers Silver Mountain Targets Owner amp User Manual SILVER MOUNTAIN TARGETS Components T Mark 600X Target Controller 1 Yellow Pelican case with built in Target Controller and rechargeable battery Temperature probe Radio Ethernet cable radio oe es Dual microphone unit with attached cables 6 Single microphone units x3 with attached cables 7 Mounting plates x4 8 Battery charger S10 Server 1 Orange Pelican case with built in Server and rechargeable battery 2 8 GB USB stick the hard drive for the Server 3 Battery charger Note To purchase extra components to have on hand as back ups or to ease transition between target frames contact your local Silver Mountain Targets dealer Silver Mountain Targets Owner amp User Manual 5 SILVER MOUNTAIN TARGETS Installation Setup amp Calibration Targetface Installation Before heading to the range it is a good idea to boot up your S10 Server to make sure the Targetfaces that you want have been installed Your S10 Server ships programmed to your specifications If you find that you need further Targetfaces proceed as follows Get the Targetfaces that you need 1 Ask your Silver Mountain Targets dealer for a Targetface Definition File 2 Receive the file on a USB stick or over the internet 3 Save the file on a computer with wireless capability such as a laptop Install the Targetfaces on your S10 Se
6. Owner amp User Manual 26 SILVER MOUNTAIN TARGETS Usage and Maintenence Issues A delayed shot report usually indicates intermittent loss of connection either between the Target Controller and the Server or as is more likely between the Server and your device o Ifa Target Viewer device loses WiFi contact with the Server the message lt Ready gt is replaced with FAIL server connection down When WiFi contact is re established the page should return to a Ready state if not refresh the browser page on your device o Connection problems between the Server and your device are often fixed through a minor elevation or reorientation of your device FAIL server connection down 6 2952 2952 1695 1733 1861 5 5 1 2 2 El CLEAR o An optional Signal Repeater can be used to extend the Wifi coverage area near the Server if required Please contact your local Silver Mountain Targets dealer for more information e In the case of a temporary loss of connection between the Target Controller and the Server any shots fired while the connection is down will be picked up once the connection is re established e When charging the T Mark 600X or S10 Server batteries if the charger light doesn t turn red when you plug it in there is likely a malfunctioning fuse in your unit You can easily buy replacement fuses at any electronics shop Silver Mountain Targ
7. SIE UAL WENES Silver Mountain Targets Owner amp User Manual SILVER MOUNTAIN TARGETS Contents SMT System Overview FOW It WOKS AN A a 3 What It 1Sand What TE IS Notarias A AA A A tn 3 Technical Specificati nS ss rsseinn eicere roninai eaaa ian iat aiaa EEE inae 4 Components T Mark 600X Target Controller ii 5 S10 SENE A A O amaa da aa Eaa Taa Eain 5 Installation Setup amp Calibration Targettace Installation coin ar a 6 Mounting Plate Instala te cs ce ree ec ecco es eee ese a mee ce 7 T Mark 600X Target Controller Setup can cai 9 E taveceascauncte nadavaicovaniea vaded sdaludbeSuesunedlsn davanes Seaton usadin ladaudvauh deeitel diseusdusddavadabvieas Sineqens 9 Temperature Probe cccccccceeccceaeeeeeeeeeeeeeeceaaeeeeeeeeeeeeeeeaaaeaaceeeseeeeeeesaaaaaeeeeseeeeeessaaaaeneeeeseeees 10 A NN 10 O 11 S10 Snell Bis E a E S 14 A 14 ES E E gesuutsbede ed cindeiysaSeneatdaadce anaehaes vanuassedagvaneverals iniciada 14 BE 8 Fe Y DOVICES ae ee a E ee ere 15 SoftWare SetU ni A A AA AAA 15 ANGST o A PP A 19 Operation ela 281 Ta O A O Eo 21 A A eer ner eee ene ee re 21 End of AY orne a eae acer rea ces ee ce Saeco E T T E 22 AN nn en 24 Troubleshooting amp Service Troublesha citadino 25 A ohana opereec antennae e e 29 Contact International Dealer aia 30 Silver Mountain Targets Owner amp User Manual 2 SILVER MOUNTAIN TARGETS SMT System Overview How It Works The Silver Mountain T
8. SILVER MOUNTAIN TARGETS Server Issues e Ifthe S10 Server USB memory stick fails the Server will not boot On your device you will be able to connect to WiFi SilverMountainTargets but you will not be able to load the splash page If you experience an actual Server crash please contact your local Silver Mountain Targets dealer for servicing Administration Page Issues e Refreshing the ADMIN functions page makes the first top left TargetFrame in the TargetFrame Setup Geometry and Calibration section active for modification regardless of which TargetFrame was active prior to refreshing Inthe TargetFrame Setup Geometry and Calibration section when you create a new TargetFrame and tap or click the SAVE this TargetFrame data button you are automatically returned to the create new target screen and not your newly created TargetFrame e When setting up multiple TargetFrames use the locn_x mm field in each target s TargetFrame Setup Geometry and Calibration section to define the physical location of the targets on the range relative to each other T1 0 T2 3000 T3 6000 This determines the order in which the live feed miniature Target Viewers appear at the bottom of the splash page o Note that the Target Viewer icons at the top of the splash page are listed alphabetically and not necessarily in accordance with the physical locations of the targets Silver Mountain Targets
9. al values which are added to all future shots on this TargetFrame Silver Mountain Targets Owner amp User Manual 19 SILVER MOUNTAIN TARGETS 9 Determine the accuracy of the AirTemp e reading displayed below the worksheet mic_width mm For errors greater than 1 C 2 F adjust the elirono_spacing mnm temp_cal C field T xea 1 Increase temp_cal if AirTemp is too na low sensor geometry STD locn_x mm 2 Tap or click the SAVE this el ED TargetFrame data button J 10 Optional Repeat from step 5 to confirm that the calibration was succesful Silver Mountain Targets Owner amp User Manual 20 SILVER MOUNTAIN TARGETS Operation Range Officer The typical daily routine for the Range Officer in charge of a range with an installed and calibrated SMT system involves the following Start of Day 1 Set up the T Mark 600X Target Controller s a Place Target Controller at Target Base p 9 b Turn Power On p 9 c Deploy Temperature Probe p 10 d Connect and Mount Radio p 10 11 e Mount and Connect Microphones p 11 12 2 Set up the S10 Server a Place Server at Firing Line p 14 b Turn Power On p 14 c Connect Display Device p 15 3 Set up the Software a Access the Administration Page p 15 b Activate the required Targetface s for the TargetFrame s to be used p 18 gt On the splash page you
10. argets e target system uses microphones to triangulate the position of shots on the target face The microphones are adjusted to pick up only the shockwaves generated by supersonic bullets The computer in the Target Controller detects the shockwave at each of the four corner mounted microphones as well as separate velocity and temperature readings The Target Controller sends this information via radio to the computer in the Server at the firing line which in turn calculates shot positions and broadcasts this over WiFi viewable by anyone in the area with a WiFi browser device What It Is and What It Is Not The SMT system is an open sensor target system It is self powered lightweight and affordable no wear items The system is portable enough that it can easily be carried by one person The limitations of open sensor systems are that only supersonic bullets can be detected and that measurement accuracy is affected by air motion The SMT system is not a chamber target system Chamber systems have microphones enclosed in a protected air space which measure impact noise Chamber targets are more expensive incur regular maintenance costs and require several people to set up System Open SMT Chamber eight target 10 kg 50 kg Cost target 3 500 10 000 Maintenance Wear items No Yes Easily portable Yes No Bullet speed Supersonic only All Accuracy Very high Near perfect Silver Mountain Targ
11. e for a shooter using a range with an installed and calibrated SMT system involves the following 1 Receive your assigned TargetFrame name and physical shooting position from the Range Officer 2 Access the SMT System a Connect Display Device p 15 b Access the Target Viewer for your assigned TargetFrame i Tap or click the TargetFrame icon that has your assigned TargetFrame name written across its top 3 Use the Target Viewer as follows e Zoom In Tap or click anywhere within the large target viewing grid e Zoom Out Tap or click either the one step or the full Zoom out button e A list of shots fired beginning with the most recently taken shot is shown gt Newly fired shots are displayed extra large for 10 seconds e To clear the display of shots tap or click CLEAR e To retrieve previous shots tap or click the previous shot button located beneath the CLEAR button T1 s DCRA TR 300m TT o DCRA TR 300m DCRA TR 300m DCRA TR 300m UNZOOM OTHER TARGETS e Zoom In Other Targets Tap or click on any of the small target viewing grids e Zoom Out Other Targets Tap or click the UNZOOM OTHER TARGETS button 4 Shoot and record your shots as you usually would but with the benefit of immediate accurate feedback on your shooting Silver Mountain Targets Owner amp User Manual
12. e of the T Mark 600X Target Controller and all of its components correctly set up Silver Mountain Targets Owner amp User Manual 13 SILVER MOUNTAIN TARGETS S10 Server Setup Location The Server stays at the firing line within 50m of all shooters and in direct line of sight with the radio s at the target line It can serve up to 10 separate Target Controllers Place Server at Firing Line 1 Place the orange box at the target line behind beside or between the shooters It must have a direct line of sight with the radio of each target it is serving gt Leave the lid of the box wide open on hot days to ensure adequate air circulation On wet days the lid may be left mostly or fully closed gt The Server must be within 50 meters of all shooters using its targets to ensure that they can connect via WiFi Power As with the Target Controller the power can be turned on at the beginning of the day and left on until the end of the day Turn Power On 1 Press the button marked Power on the S10 faceplate revealing the red power on indicator marking gt There is a 75 second boot up time after which WiFi becomes available gt The Server should not be turned off without first performing a soft shutdown from your display device see p 22 Silver Mountain Targets Owner 8 User Manual 14 SILVER MOUNTAIN TARGETS Display Devices The operation for most display devices is similar The SMT software
13. ets Owner amp User Manual SILVER MOUNTAIN TARGETS Technical Specifications T Mark 600X Target Controller S10 Server Dimensions 47x35 7x17 6cm 18 5 x14 06 x6 93 41 6x22 1x33 4cm 16 4 x8 71 x13 15 Weight 9 5kg 21 Ibs 8 5kg 19 Ibs Temperature Range 10 C to 45 C 10 F to 115 F operation 20 C to 60 C 0 F to 140 F storage Case Pelican 1500 yellow Pelican 1430 orange Power 12V7Ah sealed lead acid rechargeable battery 12V12Ah sealed lead acid rechargeable battery Power Consumption 350ma 12V 600ma 12V Run Time At least 10 hours Battery Charger Included universal 100 250V input Fuses 3 Amp 6 3mmx32mm 0 25 x1 25 Connectivity External 2 4 GHz WiFi radio Internally mounted 2 4 GHz WiFi radio with directional antenna Range 1 000m 1 000m targets 50m WLAN Cable CAT5 ethernet cable 15 N A 5 polyurethane encapsulated Microphones weatherproof N A Mounting Plates 4 acrylic keyed magnetic N A Cables 5 coaxial RG 174 50 Ohm N A 14 lower 3 20 upper 2 Computer Hardware Microprocessor 12 VDC 1 GB RAM dual core ARM processor Software Browser based open source Compatibility device Most WiFi capable portable Works well with Firefox Safari and Chrome Internet Explorer and most BlackBerry devices are not currently supported devices with
14. ets Owner amp User Manual 27 SILVER MOUNTAIN TARGETS Replacing the T Mark 600X and S10 Server Batteries Both batteries are sealed lead acid rechargeable batteries They are designed to have a lifetime of 150 charge discharge cycles You will need to replace them every 3 years or as required The T Mark 600X battery specifications are as follows o Panasonic PS1270 or equivalent 12V7AH 8AH and 9AH batteries will also work o 5 95 x 2 56 x 3 71 151mm x 65mm x 94mm o Terminal Type F1 or F2 Adapter taped to the underside of Battery cover To change the T Mark 600X battery 1 Unscrew the lid to the battery compartment 2 Pull the terminals off 3 Take out the old battery may have to turn unit upside down 4 Replace the battery terminals and battery compartment lid The S10 Server battery specifications are as follows o Panasonic PS12120 or equivalent 12V12AH o 5 95 x 3 86 x 3 71 151mm x 98mm x 94mm o Terminal Type F2 To change the S10 Server battery 1 Take the orange box apart a Unscrew b c Remove the battery cage Pull the terminals off Take out the old battery a hb Y N Replace the battery and cage put the orange box back together Silver Mountain Targets Owner amp User Manual 28 SILVER MOUNTAIN TARGETS Service If factory support or software updates are required you will need to do the following e Through your local Silver Moun
15. getface definition files 5 Tap or click the SAVE this TargetFrame data button An icon for each Targetface that you selected will appear below the Targetface Activation sub heading in the RANGE OFFICER CONTROL section at the top of the screen Silver Mountain Targets Owner amp User Manual 17 SILVER MOUNTAIN TARGETS Activate the Targetface 1 Scroll up to the RANGE OFFICER CONTROL section ADMIN functions return to splashpa RANGE OFFICER CONTROL Match Relay Mode reeform Mode Targetface Activation 2 Tap or click the Freeform Mode button This button should be green 3 Tap or click the Targetface icon that corresponds with the target face that is currently attached to your target frame The Targetface button that you select becomes green 4 Tap or click the return to splashpage button at the top of the screen gt This takes you back to your customized splash page below the SMT logo you should now see an icon with the name of your newly created TargetFrame at the top gt A TargetFrame will not show up on the splashpage until one of its Targetfaces is activated DCRA TR 300m EN TANI LS a Silver Mountain Targets Owner amp User Manual 18 SILVER MOUNTAIN TARGETS Target Calibration You should only need to perform a target calibration the first time you install the system and whenever the mounting arrangement between
16. ibration TP addr 192 168 0 XXX i mic_height mm targerface angle mils y_cal mm fallback temperature C m4z_cal mm Jocn_y mm ENABLED DISABLED W SAVE this TargetFrame data DEL this TargetFrame data Targetfaces available on this TargetFrame Set up a New TargetFrame 1 Tap or click the New button 2 Enter the parameters of your target frame in each field as follows o TargetFrame name Your choice o IP addr 192 168 0 XXX replace XXX with the two or three digit number on your T Mark 600X battery cover o mic_width mm Centre to centre distance between left and right mics o mic_height mm Centre to centre distance between top and bottom mics Best measured at the edges as per the Mounting Plate Installation section on p 7 If measuring in inches multiply by 25 4 to get a millimetre reading gt The remaining fields should be left at their default values at this time o chrono_spacing Distance between mics 1 and 3 should be set to 200mm o targetface angle mils Usually 0 can be changed to correct for side angle tilt o x_cal mm Default is O calculated through the Shot calibration worksheet o y_cal mm Same as x_cal Shot calibration worksheet covered on p 19 Silver Mountain Targets Owner amp User Manual 16 SILVER MOUNTAIN TARGETS o temp_cal C Default is O used to calibra
17. rmly to the corners of the frame using 2 4 screws per plate Do not over tighten The plates are colour coded and numbered to correspond with the microphones and connections on the T Mark 600X They should be fastened as follows o Red 2 Top left o Green 4 Top right o Blue 5 Bottom right o Black 1 3 Bottom left The thicker black mounting plate holds the heavier dual microphone unit which must directly face the shooters on the firing line Note You must install the mounting plates at 90 angles and parallel to each other They do not need to make a square but they must make a rectangle with a maximum 2cm error at each corner Note The black mounting plate must be mounted exactly perpendicular to the bullet path regardless of the overall orientation of the frame see p 12 for detailed instructions Note You will need to know the distances between microphones when entering this target frame into the system Measure and record the distances between the bottom edges of one set of the top and bottom mounting plates and the left edges of one set of the left and right mounting plates Silver Mountain Targets Owner amp User Manual SILVER MOUNTAIN TARGETS Here are some good examples of different installations Silver Mountain Targets Owner amp User Manual 8 SILVER MOUNTAIN TARGETS T Mark 600X Target Controller Setup Location The Target Controller and all of its components sta
18. rver Connect Radio 1 Plug the loose end of the ethernet cable into the receptacle marked Radio PoE on the T Mark 600X faceplate gt There are status lights on the back of the radio o PWR Comes on when power is applied o LAN Indicates a working Target Controller o Signal Strength Meter Indicates the strength of the connection to the Server Provided the Server is within range and powered on you should expect the red orange and at least one green light to come on 25 seconds after the radio has power Silver Mountain Targets Owner amp User Manual 10 SILVER MOUNTAIN TARGETS Mount Radio 1 2 Detach the hook velcro strip from the loop velcro strip stuck to the back of the radio Peel the adhesive backing off the hook velcro strip and stick it to the target frame in such a way that the radio when mounted will have a direct line of sight to the S10 Server at the firing line The radio should be placed either above or below the waterline to avoid being struck by bullets blown sideways by a wind change Mount the radio on the target frame using the velcro strips As long as it is pointed up range and has a direct line of sight with the S10 Server you should expect to see good signal strength Microphones Mounting and connecting the microphones is made simple by the in place colour coding custom keying and numbering systems Mount and Connect Microphones 1
19. rver 1 Turn on your S10 Server see p 14 2 Connect your computer to the SMT WiFi network see p 15 3 Log into the Administration Page see p 15 and scroll down to Upload targetfaces field of the SPECIAL shutdown etc section SPECIAL shutdown etc 4 Tap or click the Choose File button and use the browse function to locate ad the Targetface Definition File on your SERVER saf shotslog computer shutdown csv 5 Tap or click Submit gt This will generate either a list of Targetfaces uploaded or an error Upload targetfaces message Choose File tgtdefs DCRA txt FO ae a a ee Re ee ee ee ee ee aD 6 Tap or click the back button on your browser to return to the ADMIN Su bm it functions page a B x b a a a 4 7 Shut down your S10 Server see p 22 Note Targetface Definition Files are written in JavaScript Advanced users may feel comfortable modifying and customizing their own files Silver Mountain Targets Owner 8 User Manual 6 SILVER MOUNTAIN TARGETS Mounting Plate Installation The SMT system can be used with both conventional manually operated targets and fixed installation target frames The microphones and radio are attached to the target frame using acrylic mounting plates and velcro Install Mounting Plates 1 Remove the protective paper covering from the mounting plates 2 Fasten the mounting plates fi
20. should see an icon for the TargetFrame s you just enabled each with the name of the activated Targetface at its bottom 4 Assign shooters to the correct TargetFrames and start shooting Silver Mountain Targets Owner amp User Manual 21 SILVER MOUNTAIN TARGETS End of Day 5 era o S10 Server at the end of the SPECIAL shutdown etc a Access the ADMIN functions page ae potion DEBUG and scroll down to the SPECIAL shutdown sv shutdown etc section b Tap or click the SERVER safe o gacs shutdown button c After 30 seconds physically turn off the Server by pressing the Power button on the S10 faceplate hiding the red power on indicator marking 6 Take down and stow the SMT system equipment repeating for each T_Mark 600X a Turn off the Target Controller by pressing the Power button on the T Mark 600X faceplate hiding the red power on indicator marking and disconnect all cables b Remove each microphone and neatly wind each cable around its respective microphone If you do not do this the equipment may not fit the storage compartment c Remove the radio and neatly wind the ethernet cable gt This is a good time to inspect for nicked crushed or otherwise damaged cables and equipment Should you require any replacement parts be sure to contact your local Silver Mountain Targets dealer d Carefully place all components in the Target Controller s
21. tain Targets dealer arrange a time and place to collaborate with Silver Mountain Targets support team At the appointed time 1 Have your S10 Server booted up and running 2 Connect a cable from the ethernet port on your S10 Server to the LAN port on a router that is connected to the internet a wired internet connection gt When you plug the cable into the LAN port the corresponding port activity light should light up if not use a new cable or a different port or both 3 Follow the directions of the Silver Mountain Targets support team Silver Mountain Targets Owner amp User Manual 29 SILVER MOUNTAIN TARGETS Contact International Dealers Australia Aubrey Sonnenberg electronictargets biz gmail com Silver Mountain Targets Australia Sydney NSW electronictargets biz Canada Daniel Chisholm daniel chisholmn gmail com Silver Mountain Targets Canada Ltd NB Canada silvermountaintargets com Europe Peter Hahn peter silver mountain targets com Silver Mountain Targets Europe CAW Westphal Group Germany silver mountain targets com New Zealand John Hastie j hastie xtra co nz Silver Mountain Targets Australasia Limited United States Wayne Forshee rightsightguy gmail com Stallings Machine Ltd Georgia USA stallingsmachine com Silver Mountain Targets Owner amp User Manual 30
22. te temperature probe o fallback temperature C Enter a seasonally appropriate temperature will be used if the probe is missing or failed o sensor geometry STD Set to STD for conventional mic geometry rectangular o m4z_cal Usually 0 can be changed to correct for a twisted frame o locn_x mm Physical location on the range usually 3000mm between targets T1 0 T2 3000 T3 6000 See p 26 o locn_y mm Not currently active can be used to indicate vertical target position o targetframe enabled Tap or click the ENABLED button 3 Scroll down to the Targetfaces available on this TargetFrame section locn_x mm betframe enabled EN D j DISABLED Y SAVE this TargetFrame data DEL this TargetFrame data Targetfaces available on this TargetFrame L300y DCRA TR 500m DCRA TR 500y DCRA TR 600m DCRA TR 600y DCRA TR 700m DCRA TR 800m DCRA TR 900m 18 WSAVE this TargetFrame data Shot calibration worksheet 4 Tap or click on any target faces that you think you might use with this target frame certainly remembering to include the target face currently attached to your target frame gt This can be performed again as necessary should you miss a target face that you might want want to use in the future gt Targetfaces come pre loaded on a customer by customer basis Contact your local Silver Mountain Targets dealer for additional Tar
23. torage compartment e Ensure that the temperature probe is swung aa AN M back inside the case so that it doesn t get crushed when you close the lid a T Mark 600X a ll Ge po A om ee lt n Eo Radio Ls Silver Mountain Targets Owner amp User Manual 22 SILVER MOUNTAIN TARGETS 7 Clean dry and recharge each T Mark 600X and the S10 Server a Once home from the range remove any debris and set the equipment to dry b Plug the AC ends of the charger cables into AC sockets c Plug the DC ends of the charger cables into the receptacles marked Charger on the T Mark 600X and S10 Server faceplates The chargers are interchangeable gt The charger light turns green when plugged into the socket and then red when plugged into the unit indicating that the unit is charging gt The charger light will turn green again when charging is complete gt The T Mark 600X requires 1 hour of charging for every 2 hours of operation The S 10 Server requires 2 hours of charging for every 3 hours of operation Note The intended way to use the SMT system includes daily setup and takedown It is assumed that you start each day with clean dry fully charged equipment Note When storing the SMT system for the winter the batteries should be fully charged The entire system should be stored above freezing Silver Mountain Targets Owner amp User Manual 23 z Ee WENES Shooter The typical daily routin
24. y at the target line with the yellow box safely hidden the microphones connected to the mounting plates and the radio in direct line of sight with the S10 Server Place Target Controller 1 Place the yellow box where it cannot be hit by a stray bullet Turn Power On 1 Press the button marked Power on the T Mark 600X faceplate revealing the red power on indicator marking gt The battery will last for at least 10 hours before it needs recharging The power can be turned on at the beginning of the day and left on until the end of the day Silver Mountain Targets Owner amp User Manual 9 SILVER MOUNTAIN TARGETS Temperature Probe The temperature probe must stick out of the yellow box in contact with the open air but not in direct sunlight Deploy Temperature Probe 1 Ensure that the temperature probe is plugged into the receptacle marked Temp on the T Mark 600X faceplate 2 Thread the red probe tip through the hole at the edge of the case 3 Orient the case and lid such that the red tip will be in shade throughout the entire shooting day Note To achieve the most accurate shot measurements the temperature reading must be within 1 C 2 F of the actual air temperature The probe must be out of the sun and properly calibrated see p 20 Radio The radio is connected to the Target Controller via ethernet cable and then mounted on the target frame with velcro in line of sight to the S10 Se
Download Pdf Manuals
Related Search
Related Contents
TRANSVIDEO II MODE D`EMPLOI 取扱説明書 - 日立工機 FT FLEUR DE COTON.ai User manual PSI 8000 DT series Orion 9533 Telescope User Manual 5) 土壌消毒機 - 日本農業機械化協会 HUMA-36 - Parlement du Canada KAEBK06TCHAA USER MANUAL Gebrauchsanweisung DE Operating instructions EN Mode d Scarica la pubblicazione (pdf - 5,7 mb) Copyright © All rights reserved.