1. status press monitor and VDP will displays video from door station Under monitoring interface you may switch to next video from door station since the device support 8 ch videos at the same time with 1 large window and 7 small windows You may turn it off by pressing monitor button again and VDP will return to standby interface 2 2 5 5 Call Record Function Under video bidirectional talk status click call record you will see missed calls received calls and dialed calls which include information of caller and time You may go to different pages of records You also may call save delete or delete all callers 2 2 6 6 Contacts Under video bidirectional talk status click call resident you may enter contacts by clicking contacts icon on the right of call box The interface includes information of saved VDP info which allows direct operation to call add edit delete and delete all You may add by clicking blank or add button to add resident info You may edit resident info by selecting saved info and click edit button 2 3 Alarm Furction This product can be connected to up to 8 channels alarm with 1st channel as SOS button 2nd channel as gas alarm 3rd channel as smoke alarm while the remaining5 channels can be flexibly set Under sub menu there is information of protection zone status alarm records and modesetup 2 3 1 Protection Zone Status Function This device mainly displays information of
2. protection zone type current status and delay time for the 8 protection zones Users may enter setup interface of protection zone by clicking setup button password required and can set contents such as protection zone type NO NC alarm type enter delay exit delay For 1st to 3rd channels therein users can only set NO NC type for the remaining 5 channels users can set all while protection zone types consist of IR gas smoke SOS door sensor theft alarm tripwire Enter and exit time can be set to Os 10s 30s 60s 90s and 120s Delay is available only with delay alarm setup Users can make bypass and delete each protection zone or make the selected protection zone invalid once or for longer period 2 3 2 Alarm Recording Function Alarm recording mainly records information of the time alarm happens protection zone NO alarm processed or not The alarm info will be updated to management platform synchronously When alarm happens in any protection zone there will be a 15s beep locally with alarm interface pops up 2 3 3 Mode Setup Alarm of this product consists of away mode in mode sleep mode and user mode You may set each mode to on off separately for each protection zone Default setup are as follows Away mode 1 8 channels all on In mode 1 3 channels on others off Sleep mode 1 5 channels on others off User mode all off 2 4 Info Search Furction After VDP receives messages announcement sent from platf
3. PM IP 701TMD PM IP 702TMD 2 wire indoor monitors User manual eeeeeeseeeee eeeeeeseseoe seeeeeeseeoe seeeeeeeseos seeeeeseeeoece seeeeeeessee eeeeeesessee eeeeeeseeeos seeeeeeeseoe eeeeeeeseeee eeeeeeeseece eeeeeeeseoee Figure 1 6 The buttons are illustrated in Figure 1 6 Their descriptions are shown in Chart 1 1 Basic Furction Introduction 1 SOS Emergent calling management center Press the button during standby to enter arm disarm interface 2 1 Main Menu Arm This product main menu consists of four menus as video bidirectional talk alarm info search system setup in main menu upper left corner is network connection main door station connection DND setup and other status info Monitor Monitor door station video middle portion is current time month day week and time lower right corner Press this button during incoming call calling and is arm disarm button which allows selection between arm and disarm monitoring you can unlock corresponding door station Press the button when being called you can answer Call call press the button during acall you can hang it up Unlock 2 2 Video Bidirectional Talk Furction Chart 1 1 2 2 1 Bidirectional Talk Function with Management Center Under all interfaces press SOS button or call management center icon VDP will switch to calling management center status and a message will say You are calling management cente
4. call monitor unlock a apes touch screen technology E aa Alarm u Alarm Input Support8channelsalarminput lt lt Network ED Ethernet 10M 100Mbps self fit EA ia Never rone Specifications Power DC 10 15V or AV direct feed Power Standby lt 1 5W Working lt 7W Consumption 10 C 460 C Figure 4 1 10 90 RH 261mm 92mm 25mm_ L W H Working Environment Dimensions Weight 1 Try to avoid exposing VDP to bad environment such as condensation high temperature greasy dirt dust corrosion direct sunlight and etc 2 If there is abnormality after you plug in you should unplug it immediately and unplug the device from power supply You may plug in thedevice to Name Description power supply after troubleshoot Alarm Interface 8 ch alarm please see tag for details 3 Device installation and test must be done by professional staff If there is any malfunction or failure please do not try to dismount or fix it by yourself Communication May directly connect to network cable or via and please contact after sales department for assistance Port corridor exchanger Please refer to Figure 5 1 as guide a Only models with earphone have this interface Chart 4 1 Device Installation Guide Junction Eob inthe V Wall VDP Holder Suggested Height Figure 5 1
5. orm light turns on Under info search click announcement you may view announcements ranked by title and time If you select one announcement and click search you may view details of the selected announcement 2 5 Sy em Setup Furction System setup function includes user setup project setup and product introduction gy 2 0 1 1 User Setup User setup includes password setup display setup bidirectional talk setup DND setup restore default settings a touch screen sound button plus touch screen clean button setup 1 Password setup includes passwords for user arm disarm with default 123456 and anti attack password with default 654321 2 Display setup includes brightness 1 9 screensaver waiting time from 30s to 1800s with every 30s as an interval 3 Ring setup ring selection for incoming call pcm format alarm ring selection pcmformat volume 0 10 4 Bidirectional talk setup Door station ring duration 15s 30s 45s 60s 90s 120s adjustable VDP ring duration 15s 30s 45s 60s 90s 120s adjustable Door station call duration 15s 30s 45s 60s 90s 120s adjustable VDP call duration 5 min 10 min 15 min 30 min 45 min 60 min adjustable Monitoring duration 15s 30s 60s 90s 120s 180s 300s adjustable 5 DND setup select from 0 hour OH 1 hour 1H 2 hours 2H 4 hours 4H 8 hours 8H and 24 hours 24H to block out local ring 6 Restore default settings restore all user
6. r with corresponding beep When call is answered bidirectional talk begins You may end call by pressing SOS button again and VDP will return to standby interface When management center calls VDP VDP will ring You may press call button or answer icon to answer call You may end call by pressing call button again and VDP will return to standby interface 2 2 2 Video Bidirectional Talk with Door Station When door station calls VDP VDP will ring and display video from door station You may press call button or answer icon to answer call and achieve bidirectional talk with the door station While VDP is displaying video from door station you may end call and video by pressing call button or end icon and VDP will return to standby interface 2 2 3 Bidirectional Talk with VDP Click to enter video bidirectional talk gt call resident input the resident s room number i e Room 101 Unit 1 Building 1 and input 1 1 101 For VDP in current unit only room NO is required click call icon handset icon The device will be in status of calling corresponding VDP and the page displays You are calling XX X XXXX with beeps When the residents answer bidirectiona talk is enabled You may end call and video by pressing call button or end icon VDP will return to standby interface 2 2 4 4 Monitoring Function Under standby interface press monitor button or under video bidirectional talk
7. settings to default 7 Touch screen sound button may select to have sound or not when you touch screen 8 Touch screen clean button after you turn on this option the screen will be off in 45s which allow you to clean it up with a piece of dry cloth 45s later the screen will resume to normal status You may exit anytime during the 45s by pressing unlock button 2 0 2 2 Project Setup This setup includes device info network terminal restore default settings 1 Device info includes room number IP address subnet mask default gateway MAC address and version info 2 Network terminal includes door station name device type door station ID manufacture use only door station IP address network port number working status You may edit each item by clicking it a numeric keyboard pops up After you complete setup click the OK button on numeric keyboard 3 Restore default settings restore all project settings to default 2 5 3 Product Introduction This section mainly introduces product function and problems may encounter during usage 2 6 Unlock Furction Under incoming call from door station call with door station and VDP monitoring door station press unlock button to remotely unlock door 2 7 Arm Disarm Furction Under arm disarm status click arm button at the lower right corner of main menu and then select 1 from the 4 modes available away in sleep and user mode The password box pops up and you need to inpu
8. t password for arming System will enter arming status after delay ends If you select instant arming system will enter arming right after sound stops Under arm status click disarm button at the lower right corner of main menu and password box pops up You need to input password for disarming If you input correct password the system will disarm if you input incorrect password you will see a message saying incorrect password please try again 2 8 Screen Calibration Furction This product screen was calibrated before shipped out If you cannot activate icons on screen when you touch it please press unlockt arm and the product will enter screen calibration interface Following the cursor click on the 5 cursors in sequence to complete screen calibration Once you have done system will say screen calibration succeeds gy TT Technical Specifications Device Interface Instruction Technical specifications are as follows please see Chart 3 1 The device interface is shown as follows please see Figure 4 1 System Main Processor Built in microcontroller Operating System Built in LINUX system Video Video Compression H 264 Standard Video Resolution 800x480 Audio Input All direction microphone Output Embedded loudspeaker P Bidirectional Talk Support bidirectional talk Display 1 Screen Dimension 7 inch TFT full real color N Operating Mode Mechanical button SOS arm