GL1000/1100 Software User`s Manual
Contents
1. tween zor Convert then Save Save Si File Path Convert Data Format GAL All Data Between Fath O Cursors Ey Works YGL OO0APS ample EnglishiHDls Eng WDataiDetautt ghd Spot Samples 43 13 FTP Function When the GL1000 1100 and the PC are connected to a LAN TCP IP connection the FTP File Transfer Protocol function can be used to facilitate the sending of data files GL1000 1100 PC Setting Procedure Connect the GL1000 1100 and the PC to a LAN please see Chapter 4 Connecting to a PC Personal Computer for details Make the network settings for the PC IP address 192 168 1 1 Subnet mask 255 255 255 0 Default gateway Setting not required From your PC s Taskbar select Start Control Panel Network Connections Local Area Connection Next right click on Properties select Internet Protocol TCP IP and then click Properties to open the window shown below Set the IP address to 192 168 1 1 and the Subnet mask to 255 255 255 0 Click the OK button and close all the screens Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 1 Subnet mask 256 255 255 O
2. Click this button to delete the comment selected from the comment input field 29 11 Settings Screens This chapter describes the screens used to perform settings related to data capture 11 1 AMP settings This screen is used to make the analog input and logic input settings i TH HEEEEEEE I SR Threshold ea Lt av v masy i Value No Nane Desorption SS Settings tabs These tabs are used to change the setting screen settings capture and trigger functions M a i display information and so forth The amp types that are mounted in the device are displayed here Use these buttons to select the input type for each channel Please see the User s Manual for your device for information concerning the input specifications for each amp Use these buttons to select the input range for each channel Please see the User s Manual for your device for information concerning the range specifications for each amp Use these buttons to select the filter for each channel Please see the User s Manual for your device for information concerning the filter specifications for each amp The selected unit is displayed here Use these buttons to set the upper limit and lower limit values for the waveforms displayed in the waveform graph 30 No Nawe Desorption S 15 Threshold value Specify the threshold value for the logic signals here TTL 1 4 V When a logic signal of approximately 1
3. Default gateway Obtain ONS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server Make the network settings for the GL1000 1100 please see Chapter 5 Setting the IP Address or USB ID for details IP address 192 168 1 2 Subnet mask 255 255 255 0 8023 44 Open Internet Explorer enter ftp 192 168 1 2 in the URL box the 192 168 1 2 part is the IP address that was used in the GL1000 1100 network settings above and then press the ENTER key A screen similar to the one shown below will be displayed Fy ftp f192 168 1 2 Microsoft Internet Explorer File Edit View Favorites Tools Help Back j a Search Wey Folders Address Feo ff192 168 1 2 Data can be copied in the same way as for normal files When an Internet Explorer FTP connection is used login is automatically performed using an anonymous account and the files become read only files The following operations cannot be performed for read only files Upload file Delete file folder Create file folder Change file name folder name To enable data to be written to the GL1000 1100 the login account name must be changed Please use the following table as a guide The following procedure is used to change the Internet Explorer login account Go to the File menu and select Login As to open the Login As dia
4. ED Es 67 wae Size bytes 5144 Day Updated 2006 06 23 Time Updated 11 30 z Register as frequently used folder 10 5 Superimpose Link The Superimpose Link screen is displayed when the Superimpose Link button described in Section 10 5 is clicked The Superimpose function displays multiple data files superimposed on one waveform and is therefore ideal for comparing the amount of change The Link function enables several data files to be linked together and displayed as one file Note Only files that were captured using the same sampling interval can be linked File Hame Bias st Tne 20060626 132700 0DT AEG 1 To delaia multiple flee press ihe SHIFT or CTRL key There are files that cannot be linked About Sues Anke files Description 1 File List The files selected for the superimposing or linking operations are displayed here in a list format The path for the data capture file that is being replayed The time at which data capture was started The data capture time Sampling Interval The sampling interval Click this button to open a screen for adding a file Click this button to delete the selected file from the list Click this button to display the superimposed files 5 Link Click this button to display the linked files 6 Normal Click this button to display the original file in its normal status 7 Cancel Click this button to close the screen without performi
5. Select the device driver you want to install for this hardware window click Have Disk In the Locate File window browse the CD ROM select USB DRIVER gt GTCUSBR INF and click Open Return to the Select the device driver window and click Next Installing the driver Windows XP starts installing the driver Depending on the OS setting The software you are installing has not passed Windows Logo Testing to verify its compatibility with Windows XP message may appear Simply click Continue Anyway Completing the installation The Completing the Hardware Update Wizard window appears Click Finish to exit the wizard Windows 2000 Driver software is to be installed for the first time Installing the USB Driver 1 Starting the wizard Connect the USB cable to the PC and the GL1000 1100 The Found New Hardware wizard appears In the Found New Hardware Wizard window select Search for a suitable driver for my device Recommended under What do you want the wizard to do and click Next In the Locate Driver File window select CD ROM drive under Optional search locations and click Next Browse the CD ROM select USB DRIVER gt GTCUSBR INF and click OK The wizard found a driver message appears Click Next Completing installation The Completing Found New Hardware Wizard window appears
6. Ks Chose No Name Desorption adjustment adjustment Enter the rated output and calibration values here enabled for the DCB amp values only Click to perform setting of the specified rated output and calibration values enabled for the DCB amp only Auto balance Click to perform auto balance enabled for the DCB amp only 32 11 2 Data Capture Trigger Settings Settings such as the Sampling Interval Device Capture Settings and PC Capture Settings are made at this screen SSE es p p amefnginterval tmsoc wf 2 mdsyonour4ann 000sec evice Capture o ok wf 2 Number of channels SCH ute ma 0 mmr tothe Same Block 7 PC File PC File Settings About Compressed Data OSday OShour 27min 57 660sec 10 Trigger Settings 13 niee 9 on we 4 Device Use this button to select the sampling interval for capturing data to the Sampling Interval device Device Capture Select the capture destination for the device Device Memory Data is captured to the device s internal memory Data stored to the device memory is deleted when the power to the device is turned off Be sure to save the data to a disk or other memory device before turning the power off Data is captured to the hard disk or to a PCMCIA card 3 Block Size When the device capture destination is Device Memory use this button to select the block size icase note that if the peer size is changed
7. Loading the data between Click this icon to load and replay data from the device the cursors that corresponds to the section of data between the cursors in the currently open compressed data file Loading all the data Click this icon to load and replay data from the device Be that corresponds to the currently open compressed data file 21 Nae o Icon Description Cursors A B Click this icon to display the cursors within the waveform Max Min Click this icon to display the maximum and minimum values for each channel Comment input Click this icon to enable a comment to be input at the Cursor A position within the waveform Up to 20 characters can be input for the comment Search Click this icon to search for the desired level values and the maximum minimum values Display the CursorA B i n Click this icon to enable selection of the level A B level displayed in the digital area See A Cursor A level value B Cursor B level value AB The difference between the levels for Cursor A and B Manual trigger Click this icon to generate a trigger when Manual Trigger has been specified Memory status E Click this icon to browse the memory s data capture status Waveform operation icons Enlarging the Click the corresponding icon to enlarge or reduce the Waveform Reducing the waveform display in the X axis direction Waveform Enlarging the Click the corresponding icon to enlarge or reduce the Level Reducing the Level wavef
8. Next Installing the driver Windows XP starts installing the driver Depending on the OS settings the following error message may be displayed The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows XP Click the Continue button to proceed with the installation Completing installation The Completing the Found New Hardware Wizard window appears Click Finish to exit the wizard Windows XP Driver software is already installed Updating the USB driver 1 10 N Opening Device Manager Select Control Panel gt System gt Hardware tab or right click My Computer select Properties gt Hardware tab gt System Properties window and then click the Device Manager button In the Device Manager window open USB Universal Serial Bus Controller Confirm that Graphtec DM GL WR Series USB Driver is shown Right click it and select Properties Updating the driver Select the Driver tab and click Update Driver Starting the update wizard The Hardware Update Wizard appears Select Install from a list or specific location Advanced under What do you want the wizard to do and click Next In the Please choose your search and installation options window select Don t search will choose the driver to install and click Next In the
9. Pe lI lol ele niniGiGgiGginigqengoeo Fes bee ber ee fes iro r I I Ie Is JLo Far C36 98 100 10r 102 1081018 fs fs Fra ve v6 107 fe fs20 sn Jfs2 fs Js Jas Co ae ah Co Ses Hoa e m i Blais l lanl ao lf ar u 0 w I vais co R O s ilo l siio lis oli n lol aya is iia 12 ho ho Co 34 11 2 2 PC Capture Destination Settings The screen that is normally used to open Windows is used to make the settings for the PC save destination Look in Data O e e am Memory My Recent Documents File name My Network Files of type Custom Pattern GMD x fi Select Cur Dir 35 11 2 3 Internal Trigger Settings No Name Desorption S Level AND The trigger is activated when all of the target channels satisfy the trigger condition After all of the target channels have reached a level that does not satisfy the trigger condition the trigger is activated when any one of the target channels satisfies the trigger condition Edge AND After all of the target channels have reached a level that does not satisfy the trigger condition the trigger is activated when all of the target channels satisfy the trigger condition Trigger Counter This parameter can be used when the combination setting is Level OR or AND Count The trigger is activated when
10. Settings Change Settings CP IP Settings IP Address 1924 1684 14 ed Subnet Mask 2554 2554 2554 HO Port Number 8023 Enter select Exec register When using the PC The Configuration Tools utility is used when the PC is used to make the settings The Configuration Tools utility is provided together with the software that comes with the GL1000 1100 Please see Chapter 6 Installing the Software for the software installation procedure Before installing the software make sure that the USB driver has been installed according to the procedures given in Chapter 3 Installing the USB Driver Connect the GL1000 1100 to the PC using a USB cable Select Start HARD DISK LOGGER Software GLCOBFIG P GL1000 1100 Configuration Tools File Help Current Settings New Settings LAN IP Address 0 0 0 0 Apply Sub Net Mask 0 0 0 0 Port Number 0 o Apply 0 7 Apply MAC Address 00 00 00 00 00 00 USB Apply Device ID 0 Firmware Version Main 0 00 Printer 0 00 Read USB settings Click the Read button in the USB section to display the current device ID To set a new device ID enter the new device ID in the input box and then click Apply Turn off the power supply to the GL1000 1100 and then turn it on again to apply your setting TCP IP settings Click the Read button in the LAN section to display the current settings Enter the new values for each
11. below the specified trigger level 6 OK Click this button to enable your settings and close the screen Click this button to cancel your settings and close the screen 11 2 4 Trigger Level Settings The trigger level conditions for analog channels are specified at this screen Upper 50 0 1 100 0 50 0 0 0 50 0 100 0 Description Numerical input Enter the numerical values for the upper and lower limits and the range ry T a Click this button to apply your Level settings Click this button to cancel the Level settings and close the screen Cursor specification Use the cursors to specify the range 37 11 3 Other Settings This screen is used to make various other settings Graph Display E Other Foo Temp Compensation Save the settings to the devine T 00 03 76 01 01 115 copyright 22008 Graphtec Corp Al righs reserved a rr Room Temp This parameter is used when thermocouples are used to perform Compensation temperature measurement After you have selected your setting turn off the power to the device and then turn it on again Always select On for this setting Save the settings to the Use this button to specify whether or not to save the software settings to the device device If Off has been selected the device returns to the setup status it was in prior to the software being connected when it is restarted Return to Factory Click this button to return the sett
12. between cursors and FFT between cursors ona large easy to read screen 5 me Stet Time a pture Time Sampling Interval 2006 07 07 9 01 58 0 00 18 850 000 000 1ms Print Screen Save Screen Connect F5 Replay PC data Save Screen Print Screen 100 Devicel cH z Start Time Capture Time ae IES ctw Paused pira Start F7 Stop F8 ER Nels EET window 84844 le Hanning Y Real time Display Compre sed Data Display fal S 7 Capture Time Sampling Interval O07 9 01 58 0 00 18 850 000 000 1ms Print Screen Save Screen o Range X Axis Y Axis p on cH1 x CH2 xi l un ony CHI vi CH3 v 3 a alll con ow on wf alll con ow con wf Range Position 0 4000 X Axis CHIC 0 0013 Y Axis CH20V 0 0025 Drawing method Average wi esi Pe eae Easy operation The large size icons are easy to understand and waveform operations are simple even for first time users 0000 p 1 1 Li 1 0 5000 0 4000 0 2000 0 0000 0 2000 0 4000 0 5000 CHICV Changing the time axis enlarging or reducing the span and changing the waveform position are all functions that are easy to perform q Drawing method Average vi 0 5 10 15 20 25 30 35 40 oo 55 eae peal gal z oe a e min Max Min display The maximum and minimum values of the captured data can be checked at any time by simply clicking on t
13. condition is satisfied button is clicked button to make the Level condition setting 12 Pre trigger Use this button to capture data prior to the trigger being activated If the capture destination is Device Memory Specify the percentage of the data to be captured prior to the trigger being activated with respect to the capacity of one memory block If the capture destination is Disk Select whether or not to include data prior to the trigger being activated 13 Trigger Stop Condition This parameter specifies the trigger condition for stopping data capture condition is satisfied button is clicked Data capture stops when data capture has been performed for the specified length of time button to make the Level condition setting 3 Pe Capture Time When Time has been selected for the trigger stop condition use this button to specify the capture time Repeat Capture Use this button to specify repeat capture when the memory becomes full or when a stop trigger has been activated When the data capture destination is Device Memory Data capture is performed repeatedly when the memory becomes full or when a stop trigger has been activated When the data capture destination is Disk Data capture is performed repeatedly when a stop trigger has been activated 11 2 1 Device Memory Settings The device memory settings are made at this screen Please see the User s Manual for your device for details Co inning
14. connection uses the following items Use the following IP address IP address 192 168 1 1 Subnet mask 255 256 255 Install Uninstall Description Use the following DNS server addresses Allows your computer to access resources on a Microsoft Preferred DNS server aa eee network Alemate DHS server C Show icon in notification area when connected Cancel 14 6 Installing the Application Software This chapter describes how to install the application software 1 2 3 4 Insert the User s Guide CD ROM provided into the PC s CD ROM drive Click the Taskbar s Start button and then click the Run icon to open the Run window Enter the CD ROM drive name and English HARD DISK LOGGER Software Setup exe as the name of the file you wish to open If the disk is in drive D for example enter D English HARD DISK LOGGER Software Setup exe in the box and then click OK to launch the installer Follow the instructions on the screen to continue with the installation Note Be sure to observe the following points when connecting the GL1000 1100 to a PC Do not connect any devices apart from a mouse or a keyboard to any of the other USB terminals on your PC Set the PC s power saving functions to Off Set the Screen Saver to Off Set the anti virus software auto update and scan scheduler fu
15. of the setting items and then click Apply Turn off the power supply to the GL1000 1100 and then turn it on again to apply your settings 13 Examples of TCP IP settings When a single GL1000 1100 unit is connected to one PC Use the following settings as a reference when the GL1000 1100 is not connected to an intra company LAN A cross over cable is used to connect the GL1000 1100 to the PC PC IP address 192 168 1 1 GL1000 1100 IP address 192 168 1 2 IP address for the second and 192 168 1 3 subsequent GL1000 1100 models the last digit 3 is incremented by one to 4 5 6 and so on inthis case the Subnet mask setting is always 255 255 255 0 inthis case the Port no setting is always 8023 PC IP address setting Windows XP Start menu Control Panel Network Connections Local Area Connection Properties Select Internet Protocol TCP IP Properties insert check in the Use next IP address checkbox make the IP address and Subnet mask settings OK Local Area Connection Properties JG Internet Protocol TCP IP Properties g z pe General Authentication Advanced General Connect using You can get IP settings assigned automatically if your network supports this capability Otherwise d to ask twork administrator f E9 3Com 3C918 Integrated Fast Ethemet Controller 3C9058 P E E EONS O Obtain an IP address automatically This
16. the GL1000 1100 to the PC using the USB cable and then turn the power on Install the USB driver The installation procedure depends on the type of operating system and whether or not you are installing the driver for the first time Windows XP Driver software is to be installed for the first time Driver software is already installed Windows 2000 Driver software is to be installed for the first time Driver software is already installed Windows XP Driver software is to be installed for the first time Installing the USB driver 1 2 Detecting the hardware Connect the USB cable to the PC and GL1000 1100 The Found New Hardware message appears Starting the wizard In the Found New Hardware Wizard window select Install from a list or specific location Advanced under What do you want the wizard to do and click Next In the Please choose your search and installation options window select Don t search will choose the driver to install and click Next In the Select the device driver you want to install for this hardware window click Have Disk In the Install from Disk window browse the CD ROM under Copy manufacturer s files from select USB DRIVER gt GTCUSBR INF and click OK In the Select the device driver window Graphtec DM GL WR Series USB Driver appears in the Model box Select it and click
17. to a PC Personal Computer The GL1000 1100 is connected to the PC via a USB cable or TCP IP connection Notes To use a USB cable a USB driver must be installed in the PC Please see Section 3 Installing the USB Driver for the installation procedure LAWN cables are available as straight and cross types Use the correct cable to suit the network configuration When using the TCP IP connection do not connect the USB cable to the GL1000 1100 Connection types Connection using a network cable Connecting the GL1000 1100 directly to the PC PC 6GL1000 1100 Network cable cross PC Network cable HUB Network cable straight straight GL1000 1100 GL1000 1100 10 Connection using a USB cable Connecting the GL1000 1100 directly to the PC GL1000 1100 USB cable A B type USB cable USB HUB USB cable A B type A B type GL1000 1100 6L1000 1100 11 5 Setting the IP Address or USB ID These settings are performed to connect the GL1000 1100 to the PC The setting method varies according to whether the device monitor option or the PC is used to make the settings Please select the method that suits your usage environment When using the monitor USB settings Click the SYSTEM key twice to display the Options screen If the Device ID parameter needs to be changed specify the new ID Turn off the power supply to the GL1000
18. 0060622 175907 GDT Size byes 739534 Day Lintaled 2006 06 22 Tame Updated 71 26 18 Time Updated 17 5614 20060622 175743 GDT Size bytes 192001972 Day Updated 200606022 Tame Updated 17 57 58 Device Use this button to select the master device when multiple devices are linked together Moveup Click this button to move up to the next level Order Use this button to change thefileorder OSS Device Memory When replaying data that has been saved to the device click this button to Frequently used Folder select the device s internal memory When replaying data that been saved to the PC this button can be used for registering a frequently used folder File List The replay files are displayed in a list format Select File Click this button to select a file to replay 10 Cancel Click this button to close the screen without replaying any data 24 Review PC Screen Drive File Location E iM E My Works GL1000 4PS iSample Data Register as frequently used folder Double click to move 2006 06 26 Size bytes 2 Day Updated 2006 06 26 Time Updated 13 37 l 2006 06 23 Size bytes 6 Day Updated 2006 06 23 Time Updated 14 01 Memory Size bytes 0 Day Updated 2006 06 23 Time Updated 13 59 HDD_Data gbd Size bytes 1091212 Day Updated 2006 06 23 Time Updated 11 51 Memory_Data gbd Size bytes 53120 Day Updated 2006 06 23 Time Updated 11 50
19. 1100 and then turn it on again to apply your settings Option Settings Option Settings Screen Saver Help View Background Color Power On Start Date Time Systemi 2 4 Window Help Sets the option functions Default Disable 2006 07 07 14 15 09 New Line Code Device ID TCP IP Settings IP Address Subnet Mask Port Number TCP IP settings CR LF Change Settings 192 168 0 1 299 200 239 0 8023 Cursor Help Press the SYSTEM key twice to display the Options screen Make any changes required to the TCP IP Settings section and then press the ENTER key Enter the IP address Subnet mask and Port no and then press the EXECUTE key Turn off the power supply to the GL1000 1100 and then turn it on again to apply your settings Option Settings Option Settings Screen Saver Help View Background Color Power On Start Date Time Systemi 2 4 Window Help Sets the option functions Default Disable 2006 07 07 14 15 09 New Line Code Device ID TCP IP Settings IP Address Subnet Mask Port Number Cursor Help CR LF 0 Change Settings 192 168 0 1 29 PAD heap 8023 Option Settings Systemi 2 4 Window Help Sets the TCP IP conditions Option Settings Screen Saver Help View Background Color Default Power On Start Disable Date Time 2006 07 07 14 15 09 Cursor Help New Line Code CR LF Device ID 0 TCP IP
20. 32 11 2 Data Capture Trigger SettingS pp 33 11 2 1 Device Memory SettingS 4 34 11 2 2 PC Capture Destination SettingS 4 35 11 2 3 Internal Trigger Settings pp 36 11 2 4 Trigger Level Settings pp 37 Wi Other SEUINGS s2ccsecccuevaicessuncededastaonantsabieatnentedenesoscaeeneacsnsonce 38 12 Operating Procedure Example pp 39 12 1 System Configuration 7 39 W222 Connecouao dccatrecseeceesccseyantieanenegaqussiestestertetecesanepnaetesiecenqscaes 39 12 3 AMD SOWING S ctsccccecocnsscaccecastoarhenssacaenearede ehatencsaarensetsecesaeds 40 12 4 Data Capture Trigger Settings 4 40 12 5 Staring Data Capture cscccrveveccextecececuvicessessqesdeereesseiwiacaweceserme 41 12 6 Stopping Data Capture 4 42 12 7 Replaying Data Between the Cursors pp 42 12 8 Replaying the Device Data pp 43 EU 44 14 USB Drive MOdG ysrrsctorns am ecseranaeenainaedneeteaeneeesetsiememedtisemeecioasienaneneeeyeseimeuennaetreces 46 1 Main Features Real time waveform display Compressed data is continually being sent to the PC personal computer even while data is being captured to the GL1000 1100 at a high speed sampling rate Data waveforms can therefore be checked at any time Moreover since raw data has been captured to the GL1000 1100 the compressed data can be used to select only those sections of raw data that are actually required Raw data file Memory A variety of display formats Data can be displayed in a variety of formats Y T Digital XY
21. 4 V or higher is input the level goes High input the level goes High input the level goes High Click this button to apply your settings and close the screen Cancel Click this button to close the screen without applying your settings Apply Click this button to apply the settings made 11 1 1 Span Settings Upper 05000 fY 11000 0 5000 0 0000 0 5000 1 3000 Lover a 0 sc00 Jv No Name Description Input the upper and lower limit numerical values here The upper and lower limits can be set by specifying the cursor range Click this button to apply your span settings l 11 1 2 Scaling Settings Device Scaling Upper Upper Unit g 1ooo jv 1 00 v 100 0 50 0 00 0 50 1 00 Description Input of measured Input the upper and lower limits for the measured values here values Input of scaling unit Input the upper and lower limits for the scaling values here Click this button to enable your scaling settings and close the screen Click this button to disable your scaling settings and close the screen 11 1 3 Other Settings This screen is used to perform zero adjustment and to make calibration settings for the DCB amp Zero Adiust Avaliable for the Y M and F amps only Zero Voltage 0 0000 Callbration Aveadable for the OCB amp only 3 Rated Output t 0 000 ine Calibration alue F 0 000 nE Auto Balance Adjust
22. Click Finish to exit the wizard Windows 2000 Driver software is already installed Updating the USB driver 1 O N Opening Device Manager Select Control Panel gt System gt Hardware tab or right click My Computer select Properties gt Hardware tab gt System Properties window then click the Device Manager button In the Device Manager window open USB Universal Serial Bus Controller Confirm that Graphtec DM GL WR Series USB Driver is shown Right click it and select Properties Updating the driver Select the Driver tab and click Update Driver Starting the update wizard Upgrade Device Driver Wizard appears Click Next In the Install Hardware Device Drivers window select Display a list of the known drivers for this device so that can choose a specific driver under What do you want the wizard to do and click Next In the Select a Device Driver window click Have Disk In the Locate File window browse the CD ROM select USB DRIVER gt GTCUSBR INF and click OK Return to the Select a Device Driver window and click Next In the Start Device Driver Installation window click Next Completing installation The Completing the Upgrade Device Driver Wizard window appears Click Finish to exit the wizard 4 Connecting
23. GL1000 1100 HARD DISK LOGGER Software ___USER S MANUAL MANUAL NO APS GL1000 UM 151 Oo o a GRAPHTEC 1 Main Features wcccarcctevesscuecasdsuensctegearesentaintesdatedestenesteresententetenes 3 2 System Requirements 1 5 3 Installing the USB Driver 9 6 4 Connecting to a PC Personal Computer pp 10 5 Setting the IP Address or USB ID 4 12 6 Installing the Application Software pp 15 7 Launching the Software 4 16 SONA FION ororena ceneeentateenqeeseenteseuanesteence cess estou ar anebactest 17 9 PC Goneclonm SCUINGS ccccceccsccdsccsdcswnc dnote yc daseesmentncsenadestenesewnseuine 18 10 DISD SChOCCNS siccinceu cescenecsceneseserences A E ENES 20 10 1 Real time Display pp 20 10 2 Descriptions of the ICONS pp 21 10 3 Replay SCree n 2 2 ccc cccccc cece TERE RESER EESE ET EEE ENE VE 23 10 4 Open Captured Data Screen 4 24 10 5 Superimpose Link 4 25 10 6 FFT between Cursors pp 26 10 7 XY between Cursors pp 27 10 8 Convert then Save 4 28 1029 Maxy Min DISDlay scccocercsnotesreteskenteteasesenseacssenersdtesvertensescceetas 28 TU EN 29 11 Settings scCreenms ssaxncecorscaesdentansarceuesdersendenactetaeszecuepacedesueneetes tes 30 WS AMP SENOS oeron E E A 30 Listed Dall QeUINGS serere EE eE seanaaeseeacsenmenseeseeaess 31 T1 1 2 Scaling SCUINGS lt cccerienartenscetsctesiovecsucnalies ceiceestactedenoreneess 32 M1133 Other SEUINGS orice secendetsnrwssmecceesecseesseauvandasmecaecmteneoteesee tes
24. USB gaga Independent connection method With the independent connection method the optional B 515 device linking cable is not used A different group is specified for each device in the software to enable multiple devices to be controlled independently of each other Accordingly this connection method is suitable for when the control of several devices by one PC is required About the Connection Procedure _ the Connection Procedure _topre S See oe als connec Device Name USB ID Group Host Device 0 1 Master Device Name USB ID Group Host Device2 1 2 slave 4 Create 19 10 Display Screens This chapter describes the various screens used in this software 10 1 Real time Display vicel o Qi Paused E jip Stop F8 Oir osy 05000 Samping interval Fie Nene MEM 1 Tmsas Number 1 Level Unit i 40 0021 0 0017 0 0016 0 0019 16 124 mE 3 869 TE 0 0004 0 0002 _ Sec wi 10sec a EES E Ea No Name pesopion Connect F5 Click this button to open the Connect screen 2 Replay PC Data Click this button to replay GBD data that was captured to the PC personal computer Click this button to save the waveform display screen as a bitmap file Print Screen Click this button to print out a copy of the screen Printing is performed at the printer that has been se
25. Use the USB cable to connect the GL1000 1100 to the PC 3 Turn on the power supply to the GL1000 1100 while holding down the START STOP key 4 The USB Drive Mode screen will be displayed The illustration will differ according to the installed drive s When a PCMCIA drive is installed When both the HDD and PCMCIA When an HDD drive is installed drives are installed USB Drive Mode USB Drive Mode USB Drive Mode 5 If both the HDD and PCMCIA drives are installed use the and gt keys to select one and then press the ENTER key If only one of the drives is installed no key operations are required The GL1000 1100 will automatically switch to USB drive mode 6 When the GL1000 1100 has switched to USB drive mode a removable disk icon is displayed in your PC s My Computer window The USB drive can now be used in the same way as a normal drive 2006 06 19 2006 06 22 2006 07 07 a D N 009 BMP MES po Atal BMP 2006 06 20 2006 06 23 an BMP z p Nz Devices with Removable Storage Removable Disk H cag File Edit View Favorites Tools Help ae Q Back S P Search Folders X i Removable Disk Hi Address H v EJ co c 2006 06 14 J 2006 06 15 2006 06 16 2006 06 21 2006 06 26 ree apn U U Se SE 7 To exit USB drive mode turn off the power to the GL1000 1100 46 GRAPHTEC e The specifications etc in this manual are subject
26. and digital values can be viewed This file extension denotes binary data that has been captured to the device s hard disk 9 PC Connection Settings To connect only one device The GL1000 1100 is connected to a PC via a TCP IP connection or USB cable to enable communication between the devices 1 Click the Connect F5 button on the main menu to display the Connect screen 2 Click row 1 to reverse the display color to blue and then click the Edit Add button US B About the Connection Procedure Click to reverse the color to blue or Click the Edit Add button D 3 Enter the name of the connected device and the transmission conditions the conditions that were specified at the device and then click the OK button If a device name is not entered it will automatically be assigned the name Me Device1 l m Enter the device name gt Device Mame Device Set the IP address TCP IP connection only gt IP Address 192 168 1 00 Set the Port number TCP IP connection only gt Porto 8023 Set the USB ID USB connection only gt p g o Set the measurement group only when multiple gt Group Croup z mes om x cmoa 4 Click the Connect button to make all the connections for transmission 5 Click Close ESC to close the Connect screen If a connection error occurs please see Chapte
27. any captured data will be lost empr rr Block Number Capture method Select the data capture method block After data has been captured to the specified block it is sequentially then captured to the next block block then captured to the next empty block Disk capture CH When the device capture destination is Disk use this button to specify the number of data capture channels If the device is an 8 channel model this setting is always 8CH If the device is a 16 channel model either 8CH or 16CH can be selected If 8 CH is selected the maximum sampling speed can be specified in a range up to 1 us If 16CH is selected for the number of data capture channels the maximum sampling speed becomes 2us File Type Select the method for appending the file name A folder with the date as the file name is created in the specified folder and then a file with the date and time as the file name is created within the new folder The file name can be freely specified by the user 33 HEN Save Path Device File Settings Select the save destination at the device for the captured data here PC File Settings Select the save destination at the PC for the captured data here PC Use this button to select the sampling interval for capturing data to the PC Sampling Interval 10 Trigger Start Condition This parameter specifies the trigger condition for starting data capture Off No condition is required for the start of data capture
28. arious functions are assigned to each of the menu setting items to provide ease of use Since data is captured to the device at high speeds the data that is transferred to the computer in real time is compressed data GMD Raw data is also captured to the device at the same time After data capture has been completed the cursors can be used to select a section of the compressed data and specify receipt of the data in the range between the cursors as raw data eeClick to close the windows This parameter is used to specify the sampling interval for the data that is captured to the computer The file extension is GMD Be sure to specify a slow sampling interval A fast sampling interval may cause breaks in the displayed waveforms or data loss due to the inability to keep up with the data transfer speed Range 1V Range Trigger Level 1 0V 100 y 50 0 0 0 5 J 50 1 0 100 geeClick to close the windows 2 System Requirements Make sure that the PC on which you plan to install the software meets the following requirements Pentium 4 1 7 GHz or higher Notes Even when using a PC that meets the system requirements measurement data may not be captured correctly depending on the PC status e g running other applications or insufficient memory capacity in the storage media used Exit all other applications before capturing data to the internal hard disk Th
29. e parameter Select Off for the Filter parameter Select Off for the Input parameter for CH 2 12 4 Data Capture Trigger Settings Click the Data Capture Trigger Settings tab to open the Data Capture Trigger Settings screen Select the sampling interval for the device Select 1 ms for the sampling interval Select the device capture destination Select Disk for the device capture destination If Disk has been selected data can be captured either to the internal hard disk or to a PCMCIA card Select the device file save destination Select Auto for File Type If Auto is selected a folder with the date as the file name is created in the specified folder and then a file with the date and time as the file name is created within the new folder Select the PC sampling interval While raw data is being captured to the GL1000 it is also sent to the PC in real time and saved as compressed data Here please select the sampling rate for the compressed data Main Window Graph Display Sampling Interval Device Capture Device File Settings PC File Settings Data Capture Settings About Compressed Data ee ee _ _ OSday OShour 23min 10 31 sec 40 Select the PC file save destination Select Auto for File Type IfAuto is selected a folder with the date as the flle name is created in the specified folder and then a file with the date and time as the file name i
30. e sampling interval 2 Print Screen Click this button to print out a copy of the screen Printing is performed at the printer that has been selected as the default printer If you change the printer relaunch the software Click this button to save the displayed screen as a bitmap file Click this button to close the screen Off On Click these buttons to specify each XY display as On or Off Use this button to select the channel for the X axis Use this button to select the channels for the Y axis Cursor information The range and level information for the channels selected using the Range buttons is displayed here Display Cursor Click this button to move the cursor to the center of the graph 5 CH Settings XY settings can be made for up to a maximum of four channels Range These buttons specify display of the scale values for the channels selected for the X and Y axes 21 10 8 Convert then Save This function can be used to convert the data being replayed to a different format such as CSV All of the data or just the data between the cursors can be specified File Path Convert Data Q All Data a Between ips z eee _ E My Works iGL10004PS Gample 4 EnglishiHDLS_Eno Data Defaul ghd E Description Save format Use this button to select the data save format r _ Dedicated binary data that can be replayed by using this software Text data that can be displayed in a Microsoft Excel file Please note t
31. hat the maximum number of data points that can be replayed in Excel is 64000 Data to be converted Use this button to select the range of data for conversion Path Use this button to specify the data capture destination and file name Path 4 Spot samples Use this button to select the interval for performing spot sampling when the data is saved Example If 10 has been selected 1 point out of 10 is sampled the other 9 points are disregarded Click this button to perform the Convert then Save operation 6 Click this button to close the screen 10 9 Max Min Display This function is used to display the maximum and minimum values for each of the channels between the cursors during a data capture or data replay operation Moreover the results can be saved in the CSV file format Note The average and P P values are not displayed during a data capture operation CH Min Min Time Max Max Time Average P P aay E 28 10 10 Comment Input Use this function to input a comment above the waveform of the desired channel during a data capture operation o7 CHIC EA 2 1 s Delete Input Over Cursor A Use this button to select the channel for comment input Input the comment s in this field Up to 20 comments can be input The location of comments that have already been input can be selected with the pull down arrow and moved Click this button to enter the comment It will be input at the Cursor A position
32. his icon CH Min Min Time Max Max Time Average P P CH1 1 0 4988 06 07 07 09 01 59 0 5012 06 07 07 09 02 00 0 0683 1 0000 CH2 0 4998 06 07 07 09 01 59 9 5009 06 07 07 09 02 00 0 0689 1 0007 CH3 0 0056 06 07 07 09 01 59 9 9024 06 07 07 09 01 59 0 0002 0 0080 0 0062 06 07 07 09 01 59 9 9024 06 07 07 09 01 59 0 0004 0 0087 16 238 06 07 07 09 02 01 16 047 06 07 07 09 02 00 16 131 0 191 3 887 06 07 07 09 02 01 3 855 06 07 07 09 02 01 3 871 0 032 0 0002 06 07 07 09 01 59 49 9014 06 07 07 09 02 00 0 0006 0 0016 0 0007 06 07 07 09 02 00 9 90009 06 07 07 09 01 59 0 0001 0 0016 Printing function Screen save function The displayed waveform screen can be printed out on a printer and a copy of the screen saved as a bitmap file Note To use the printing function the device must be connected to a printer puesii RRE 100m4 paa E Ee rom 0 2 in aan Prt iB cy20060602 131152 GDT CHAA r DER o0 05 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Sec E CH PA A Litt a Eam A VIbEOIEI DMPA 0 00 02 200 000 000 DVB 0 00 03 200 000 000 4 B 0 00 01 000 000 000 Help function Help buttons that provide simple descriptions of the v
33. ick on the icons to perform the various waveform operations Drawing method With real time and compressed data displays the data sent from the device to the PC is compressed into the maximum and minimum values Use this button to change the drawing method Average values The averages of the maximum and minimum values are displayed Max values The maximum values are displayed Mean values The minimum values are displayed Interpolation A line connecting the maximum and minimum values is displayed Max values Interpolation Mean values Average values During a compressed data review operation the data may not be displayed if the PC s sampling cycle is shorter than the device s capture time In such cases use the Review Device function to check the data When the software status is Free Running status measurement stopped the device is operating in RECORDER mode and data capture is not performed 10 2 Descriptions of the Icons This software uses icons as visual representations of the file and waveform operations to make these operations easier to understand There are two main icon groups File operations functions and Waveform operations File operation function icons Name Icon Description Review device Click this icon to replay data has been saved to the device s internal memory or hard disk Opening a compressed file Click this icon to open a compressed file GMD file that has been saved to the PC
34. ings to the default values ac a 4 Software Version Version The software version is The software version is displayed here SY here Ee Device Information Information relating to the connected device is displayed here 6 Websiteaccess Click this button to access the Graphtec web site 38 12 Operating Procedure Example 12 1 System Configuration GL1000 PC with recommended 7 D USB e 12 2 Connection Connect the GL1000 to a PC Use the USB cable to connect the GL1000 to a PC and then install the USB driver please see Chapter 3 Installing the USB Driver V amp Set the USB ID Follow the instructions given in Chapter 5 Setting the IP Address or USB ID to set the USB ID The default value is 0 and this setting can be used as is Launch the software Follow the instructions give in Chapter 7 Launching the Software to launch the software application About the Connection Procedure EAIA da Delete Make the connection settings Follow the instructions given in Chapter 9 PC Connection Settings to make the connection settings and then click the Connect button 39 12 3 AMP Settings Open the Settings Screen Click the Capture Settings button on the main screen Open the AMP Settings tab Input Range Filter settings Make the following settings for CH 1 Select DC for the Input parameter Select 1V for the Rang
35. is button to save the displayed screen as a BMP file 7 Print Screen Click this button to print out a copy of the screen pv pms Printing is performed at the printer that has been selected as the default printer If you change the printer relaunch the software 8 Close Click this button to close the data replay screen O o Displayed Information The replay file information is displayed here Capture Time The data capture time Sampling Interval The sampling interval displayed here blue area is the area that is currently being displayed 23 12 Compressed Data Use this tab to perform spot sampling of the displayed data Display selection tab The percentage value indicates the percentage of the data displayed within the graph area with respect to data on which spot sampling has not been performed 50 Indicates that half of the actual data is displayed The value is automatically linked to the enlargement reduction ratio of the X axis 10 4 Open Captured Data Screen This screen is used to select the captured data Device File Location 1 ie onee E Device Memory 20060622 212727 6DT Sire bytes 1247392 Dey Upialed 2000622 Tine Updated 21 34 26 Ss 20060622 212638 GDT Size bytes 6144 Day Lintaled 2006 06 22 20060622 212613 GDT Size bytes Gidd Day Updated 2006062 20060622 211818 6DT Sire bytes 6144 Day Lindalied 20060622 2
36. is software cannot be used to control the 100 mm printer B 502 that is available separately as an option 3 Installing the USB Driver This chapter describes how to install the USB driver If you are already using a DM Series device If you selected a driver that has already been used for a DM Series device please reinstall the driver according the procedure given in the relevant subsection Driver software is already installed Checking the version of your USB driver This section describes how to view the version of the USB driver if it is already installed 1 Opening Device Manager Select Control Panel gt System gt Hardware tab or right click My Computer select Properties gt Hardware tab gt System Properties window and then click the Device Manager button 2 Inthe Device Manager window open USB Universal Serial Bus Controller Confirm that Graphtec DM GL WR Series USB Driver is shown Right click it and select Properties 3 Updating the driver Select the Driver tab and click the Driver Details button 4 Select GTCUSBR SYS to view the version of the driver file Installing the USB Driver This section describes how to install the USB driver 1 2 3 Insert the User s Guide CD ROM provided as a standard accessory into the PC s CD ROM drive Connecting the GL1000 1100 to the PC Connect
37. lected as the default printer If you change the printer relaunch the software Click this button to exit the application Device selection tab Use this tab to change the device used as the control device when multiple devices have been connected Simplified message The operating status is displayed here 1 measurement stopped status Data captured has ended Click the Stop button Compressed data Captured compressed data is replayed display Capture Settings Click this button to open the data capture settings screen to make settings Screen selection tab This tab is used to switch between the real time and compressed data displays 10 Start F7 Click this button to start data capture F8 4 5 0 11 aa Stop Click this button to stop data capture 20 SS SSS Capture Information Information is displayed here during a data capture operation Start Time Data capture start time data capture CA has been specified Capture Interval Interval The The sampling interval CSY interval Capture File Name The data capture destination file name Digital The digital values for each channel are displayed in this area Clicking the cursor on any of the CH numbers enables that channel to become the active channel The active channel is displayed in green and can be used to perform the waveform operations mentioned in item 15 below 14 Waveform sd The waveforms are displayed in this area Waveform Op Cl
38. log box ftp 192 168 1 2 Log On As X File Edit view Favorites x Login As ie To log on to this FTP server type a user name and password B New FTP server 192 168 1 2 User name gl1000 ve 168 1 2 I Password j After you log on you can add this server to your Favorites and return to it easily A FTP does not encrypt or encode passwords or data before sending them to the 1 server To protect the security of your passwords and data use Web Folders WebDAV instead Work Offline Learn more about using Web Folders Close i C Log on anonymously C Save password Enter the account name in the User Name box Leave the Password box blank Finally click the Login button 45 14 USB Drive Mode When the GL1000 1000 and the PC are connected via a USB cable the USB drive mode function enables the built in hard disk or PCMCIA drive to be recognized as an external drive by your PC and files to be transferred and copied This function can only be used when the optional TFT LCD monitor B 501 has been installed in the GL1000 1100 This function can only be used when the device is equipped with an HDD provided as standard with the GL1000 1100 or when a PCMCIA drive is installed Procedure First of all install the USB Driver please see Chapter 3 Installing the USB Driver for details 1 Turn on the power supply to the PC 2
39. n FFT or XY format Convert then Save The last step is to save the raw data that was sent from the GL1000 to the PC Click the Convert then Save button The data can be saved in either the GBD or the CSV file format GBD is a dedicated binary file format whereas CSV is a text file that can be opened in a Microsoft Excel or similar file Here we will simply click the OK button A file with the name Default gbd will then be created in the folder in which the software was installed This completes our description of the operating procedure As we have shown the GL1000 can be used after making only a few settings J FFT between XY between Open File Superimpose ink cursors cursors Convert then save Save Screen Print Screen i Capture File Name cz006 07 0720060707 1 40854 GDT Start Time 2006 07 07 14 08 55 Capture Time 0 00 07 908 000 000 Sampling Interval 1msec e Active CH CH1 CH Anno _ Level Cur A Unit Tet 0 0814 GPa sls ee Se Ee Ee Se L ee LS Le 480 490 5 00 5 10 520 530 540 550 560 570 5 80 5 90 6 00 610 620 630 640 650 660 670 6 80 Sec Cursor Time 485 0 55 6 0 65 7 0 75 8 0 85 3 0 95 100 105 110 115 120 12 7 ec ao S a E 0 00 02 504 000 000 Cursor B 0 00 07 504 000 000 Sootla T AB 0 00 05 1000 000 000 000
40. nctions to Off Also set the Windows auto update and scheduler functions to Off 15 7 Launching the Software Click the Taskbar s Start button gt Programs gt HARD DISK LOGGER Software gt HARD DISK LOGGER Software to launch the application software Once the program has started up the Connect screen is automatically displayed Points to note when launching the software ifthe GL1000 1100 models fitted with the optional TFT LCD monitor is in FFT mode press the MODE key to switch the device to RECORDER mode If the GL1000 1100 models fitted with the optional TFT LCD monitor is in REPLAY mode press the SHIFT and EXIT keys simultaneously to switch the device to RECORDER mode About the Connection Procedure 16 8 Data Flow The data flow between the GL1000 1100 and the PC is as shown below Since data is sampled by the GL1000 1100 at a high speed compressed data is sent from the device to the PC for display in real time Accordingly the data stored in the PC GMD files during a data capture operation is compressed data to be used for reference When data is being displayed during a Review Device operation sections of the compressed data data between the cursors and all the data obtained from the GL1000 1100 s hard disk or device memory become raw data This data can be converted to enable it to be saved to the PC Memory Compressed data file Raw data file Descripti
41. ng any operations 25 10 6 FFT between Cursors The data replay screen can be used to display the data between the A and B cursors in FFT format Start Time Capture Time 2008 O07 8 01 58 0 00 18 850 000 000 HE a rr a Displayed information The information for the file that is being displayed in FFT format is displayed here Start Time The time at which data capture was started Capture Time The data capture time Sampling Interval The sampling interval Print Screen Click this button to print out a copy of the screen open Printing is performed at the printer that has been selected as the default printer If you uke ule printer relaunch the SUIS 5 Save Screen ___ Ciok this button fo save ihe displayed screen as a bitmap Me _ Te Click ue button to close the screen aC o Use this button to select the FFT window function 7 Id OS Click this button to specify On for dB 26 10 7 XY between Cursors The data replay screen can be used to display the data between the A and B cursors in XY format starn Time Caples Time samping interval 20060707 amp 01 58 000 19 650 000 000 ims 00000 0 2000 04000 0 5000 CHI 0 5000 04000 0 2000 No Nane Desorption S 1 Displayed information The information for the file that is being displayed in XY format is displayed here Start Time The time at which data capture was started Capture Time The data capture time Sampling Interval Th
42. ons of the various operations and file types File type Capturing data Loading the data between the cursors from the compressed data Loading all the data from the compressed data Review Device data Compressed data GMD data Device memory data HDD data GDT PCMCIA card data GBD Device memory data HDD data GDT PCMCIA card data GBD Raw data GBD data Descriptions of the file extensions This file extension denotes files to which compressed data that has been sent from the device to the PC has been captured Since it is not raw data use it for reference only Compressed data is sent from the device to the PC and the software is used for waveform display Free Running Compressed data is captured to the PC With the cursor positions in the compressed data used as the reference points raw data is obtained from the device The Convert then Save operation is used to save the data to a file in the PC All the raw data corresponding to the compressed data is obtained from the device The Convert then Save operation is used to save the data to a file in the PC The desired section of raw data is obtained from the device The Convert then Save operation is used to save the data to a file in the PC This file extension denotes binary data files that were created by using the Convert then Save operation after a Review Device operation Data saved to these files can be reviewed on the PC and waveforms
43. orm displayed for the active channel in the Axis Y axis direction Moving the Position Click the corresponding icon to move the waveform Up Moving the Position displayed for the active channel up or down Down Waveform Display On Off Click this icon to switch between Waveform Display On and Waveform Display Off for the active channel Scale Settings Click this icon to enable changes to be made to the number of Y axis ranges and to set the number of display divisions Click this icon to display plot marks for the sampled points on the waveform Fixing the Cursors Click this icon to fix the positions of Cursors A and B with respect to the movement of the scroll bar 22 10 3 Replay Screen This screen is used to replay data that has been captured to the PC and to replay data that has been captured to the device Cuma File Meme C 2006 0 ETO TUTOR BE GOT Seite AIST onis ee Unibicninn SEA Imse 4 O 0011 0 0024 0 0024 16 126 3 303 0 0010 0 0006 oO 02 04 O8 G2 10 12 14 16 18 20 22 24 4 aes i T es eet Ce CAR OE BRROE UES DEES T Ee ae LFN A Otol ob 16 2b 30 ab b0 60 70 0 p0 100 110 120 130 MO 180 160 170 16039 52000 00 y i a 4 No Name escription OOOO Open File Click this button to open the file that you wish to replay from multiple files format format perform spot sampling of the data 6 SaveScreen Click th
44. r 4 TCP IP us Connecting to a PC Personal Computer or Chapter 5 Setting the IP Address or USB ID and check your settings Create Click the Connect button to start the connection procedure 3 Click the Close ESC button to close the Connect screen 18 To connect multiple devices There are two methods of connecting multiple devices Linked connection and Independent connection Linked connection method Linked connection is a function that enables multiple devices that are linked together using the optional device linking cables B 515 to be controlled as a single device by the software by specifying the same group number for all the devices This connection method is suitable for when multiple channels are required Note The linked connection function is not available for the GL1100 model The device with a device linking cable inserted into its OUT connector only becomes the MASTER device and is the device used as the control device A device with a device linking cable inserted into its IN connector becomes a SLAVE device and obeys the MASTER device Specify the same group number for multiple devices that are linked together this way About the Connection Procedure the Connection Procedure Tcp P P IP ql connect Device Name USB ID Group Host Device 0 1 Master a connect Device Name USB ID Group Host Device2 1 1 Master 4 Create LANor
45. raph Divisions 7 Plot hy orke YLI O0074PS Data Start Time 2006 07 07 13 49 01 Active CH l CHI Dra PLIST JST ACT Si Tas ag PSL seSL Deh Fe Jos at ait Dat et Joe GL IRR ist Test Tie Vist Jee SSS EN E at AE J ELIT Tost Te fies Jel ae MEI Nes fic Mek Jit Tet Jo oe a EL Te UL 1 1 0 5 10 25 35 ecw E Vy 2 lal E 1 2 B 4 wing method Seren sans 41 12 6 Stopping Data Capture Stop data capture Click the Stop button to stop data capture Display compressed data When data capture has stopped the compressed data that was captured to the PC can be replayed In the same way as during a data capture operation waveform operations can be performed and the A and B cursors used to view the numerical data values 12 7 Replaying Data between the Cursors The raw data corresponding to the data between the cursors that was selected using the compressed data captured to the PC can be sent to the PC from the GL1000 Cursor positions Use the A and B cursors to select the range for which you wish to obtain the raw data Load data between the cursors Click the Load data between the cursors button to load the raw data that has been saved to the GL1000 Start Time start F 7 2006 07 07 1408 54 DARS Settings J eee Ne i Zw ig pred 4 Lee File Name C 2006 07 07 20060707 140854 GDT Real time Display Compres
46. s created within the new folder The folder in which the software was installed becomes the default save destination and so we will use this folder Complete the setting procedure Click the OK button to apply all the settings that you made and close the Settings Screen 12 5 Starting Data Capture Start Data Capture Click the Start button to start data capture Check that data is being captured Data is being captured if Recording is flashing in blue on the status display The other statuses that are displayed are Armed when the GL1000 is awaiting a trigger Finished when the data capture operation has been completed and Paused when the GL1000 is in the stopped status Waveform operations The waveform for each channel can be adjusted for easier viewing during a data capture operation Select the active channel in the digital display area Only one channel can be selected as the active channel As there is only one channel in this case CH1 becomes the active channel To change the active channel to a different channel click on the desired channel number The CH row that is displayed in green is the active channel The following operations can be performed for the active channel s waveform 1 Changing the X axis display width 2 Changing the X axis scale display method 3 Enlarging Reducing the Y axis 4 Changing the Y axis position 5 Waveform Display On Off 6 Waveform G
47. sed Data Display ea Compressed File Name Ey 2006 07 07_14 08 54 GMD 0 5000 0 4500 0 4000 0 3500 0 3000 0 2500 0 2000 0 1500 0 1000 0 0500 0 0000 3 00500 T 0 1000 0 1500 0 2000 0 2500 0 3000 0 3500 0 4000 0 4500 0 5000 A Drawing method l Average Y ka ea A A Ea ganooooooonooooooonooooooonooooooonooooooonoooooooanooooooonooooooonnl 8 0 10 0 12 0 14 0 16 0 18 0 20 0 22 0 24 4 kej e a eal _ Active CH CH Anno Level Cur A Unit al ma 0 4052 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 00 10 20 30 40 50 60 70 80 930 100 11 0 120 130 140 150 16 0 170 180 19 0 200 Cursor Time Sec 0 00 00 000 000 000 Cursor B 0 00 00 000 000 000 spottLo wl as aT Ar 100 0 000 000 000 Se E My 2006 07 07_14 08 54 GMD Pe S Cursors A Cursors B 1 1 1 1 1 1 1 1 90 100 11 0 120 130 140 150 160 1 Sec to bea hel Settings l ILC alay Compressed Data Display 42 Compressed Esty 2001 12 8 Replaying the Device Data The raw data for the range specified by the cursors is displayed In the same way as during a compressed data replay operation waveform operations can be performed and the A and B cursors used to view the numerical data values Files can also be superimposed or linked and the data between the cursors can be displayed in a
48. the number of generated triggers reaches the specified number of counts Filter The trigger is activated when a signal that satisfies the 1 Combination Use this button to select the trigger combination for each channel Level OR The trigger is activated when one of the target channels satisfies the trigger condition 2 condition that it must exceed the time calculated by multiplying the Sampling Interval Time by the Number of Counts is input 36 No Nanme Desorption S 3 Analog Settings This parameter is used to set the trigger condition Function No target channel has been specified Hi The trigger is activated when the input signal rises to or exceeds the specified trigger level Lo The trigger is activated when the input signal falls to or falls below the specified trigger level The lower limit and upper limit levels for each channel are set for each channel The trigger is activated when the input signal is inside or goes inside both the specified lower limit and upper limit levels WinOut The lower limit and upper limit levels for each channel are set for each channel The trigger is activated when the input signal is outside or goes outside both the specified lower limit and upper limit levels Setting Use these buttons to specify the level 9 Logic settings This parameter specifies the logic trigger setting X Trigger detection is not performed exceeds the specified trigger level falls
49. to change without notice GL1000 1100 User s Manual APS GL1000 UM 151 June 30 2006 1st edition 01 GRAPHTEC CORPORATION 4T