Home

KDS EZFlow 2010/2011 Micro Infusion Pump User`s Manual

image

Contents

1. 50 60 100 Type BF Continuous Drip Proof IPX1 20 30 ml 50 60 ml 100 ml 0 1 ml hr 300 ml hr in 0 1 ml hr increments 2 5 41 F 104 F 5 40 C 80 10 60 Hz 25VA 12VDC 5 220VAC 10 50 Hz 25VA or 12VDC 5 Approx 13 X 5 5 X 3 5 335 X 142 X 120 mm 5 5 pounds 2 5 kg Flow Rate ml hr 0 1 150 0 1 300 0 1 300 This Micro Infusion Syringe Pump uses a precision motor for injections desired fluids Other features include SelfTest Self Diagnoses when the pump is turned on the first time Audible and Visual Alarms of Near Empty Complete Occlusion and Low Batt Wide range of compatible syringe 20 ml 30 ml 50 ml 60 ml 100 ml e Wide flow rate range 0 1 ml hr 300 ml hr in O 1ml hr increments Waterproof ergonomic touch control panel KDS EZFlow 2010 2011 Keypad Function CONTROL PANEL 18 m 3 5 79 qu 13 15 17 2 4 6 8 10 12 14 16 1 Syringe size indicator 11 COMPLETE alarm indicator 2 ACPOWER indicator 12 RAPID PURGE 3 BATTERY POWER indicator 13 OCCLUSION alarm indicator 4 INCREASE rate 14 RUN 5 Numeric Display 15 LOW BATTERY alarm indicator 6 DECREASE rate 16 STOP 7 FLOW rate 17 MUTE 8 Delivered volume 18 ON OFF switch 9 NEAR EMPTY indicator 19 Syringe plunger head 10 CHECK 20 Syringe securing bar KDS EZFlow 2010 2011 Keypad Fu KEYPAD DESC AUDIBLE AND NEAR EMPTY CO
2. ON THE BOTTOM OF THE PUMP EVERY TIME YOU USE NEW DIFFERENT SIZE BRAND SYRINGE Dose Calibration switch is located on the bottom of the pump This switch can be used to offset variances between syringes from different manufacturers as follows User must do the accuracy test for OTHER brand size syringe before use to ensure the accuracy Parts and Accessories Order Model Product 78 0550 EZFlow 2010 EZFlow Micro Infusion Pump 110 VAC 78 1550 EZFlow 2011 EZFlow Micro Infusion Pump 220 VAC 78 0551 IV Pole Mount 78 0593 12 VDC Power Plug Adapter KDS EZFlow 2010 2011 Limited Warranty KD Scientific Inc warrants to the first consumer purchaser for a period of one year from the date of purchase that this unit when shipped in its original container will be free from defective workmanship and materials and agree that it will at its option either repair or replace the defective unit This warranty does not extend to misuse neglect or abuse normal wear and tear accident modification or unauthorised repair KD Scientific will not be liable or in any way responsible for any incidental or consequential economic or property damage Some States do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you There are no implied warranties of merchantability or fitness for a particular use or of any other nature Some states do not allow this limitation on implied warranty
3. MPLETE OCCLUSION LOW BATT nction Continued RIPTION INCREASE rate Increases flow rate Press Hold to change the rate faster DECREASE rate Decreases flow rate Press Hold to change the rate faster CHECK VOLUME Press and hold RUN mode to display the volume delivered Release to display the preset flow rate PURGE Only functions in STOP mode Press to run the pump at high speed expelling air out of the syringe or to purge the syringe Rapid purging rate varies according to syringe size Syringe size ml 20 50 60 100 Max flow rate ml hr 150 300 300 RUN Press RUN button to start infusion the LED indicator lights flash STOP Press to stop pump MUTE Press to silence the alarm buzzer while NEAR EMPTY COMPLETION or OCCLUSION alarm is sounded Audible and visual alarms VISUAL ALARMS NEAR EMPTY When there is approximately 5 ml of medication left an audible and visual alarm is activated Press the MUTE button to silence the alarm buzzer COMPLETE When infusion is complete the operation stops and audible and visual alarms are activated Press MUTE button to silence the alarm buzzer OCCLUSION Whilst occlusion occurs operation stops Press MUTE button to silence the alram buzzer Infusion only continues after the alarm condition is cleared LOW BATT Audible and visual alarms are activated if the battery runs low on charge To clear the larm plug the power lead into and appropriat
4. e AC wall outlet the pump will continue to operate while recharging the battery BATTERY POWER indicator light orange is on to indicate that builtin bettery power is in use AC POWER indicator light green is to indicate the pump is connected to main AC power and is charging battery KDS EZFlow 2010 2011 Operation Instructions 1 CHECK THE DOSE CALIBRATION SWITCH LOCATED ON THE BOTTOM OF THE PUMP EACH TIME YOU USE NEW DIFFERENT SIZE BRAND SYRINGE Dose Calibration switch is located on the bottom of the pump This switch can be used to offset variances between syringes from different manufacturers as follows bp Wes 2075 STD IMPORTANT ONLY ONE SWITCH CAN SET IN THE UP POSITION IF TWO OR MORE SWITCHES ARE SET IN THE UP POSITION THE PUMP WILL REVERT BACK TO THE STD SETTING 2 3 4 5 6 7 8 Pump can be used either on any horizontal surface or on the IV pole with pole clamp Plug power cord into a wall outlet or use the DC 12V builtin battery power If using battery power charge battery at least 10 hours before use A fully charged battery can continuously support running up to 4 hours at a flow rate of 50 ml hr Turn the power switch on ON OFF switch is located at the right side of the pump When initialized the pump will go through a Self Diagnostic program After the pump passes the Self Diagnostic tests 0 1 will appear on the disp
5. e connecting the syringe user must prime the syringe and extension tube to prevent infusing air 5 To clean the pump use a damp not wet cloth or sponge Do not immerse pump or power cable into water or other cleaning solution 6 Only use the 3 Pin AC main power cord included with this pump Use of any other cord presents a hazard of shock or death to subject The AC mains outlet must be properly grounded to prevent shock hazard Main outlet and ground should be tested on a regular basis to ensure safety Operate away from strong magnetic fields 7 This pump will go through a self diagnostic program when the power switch is turned on Normally a 0 1 is shown in the display This indicates the pump is operating properly If an ERR is shown in the display reboot the pump If the error condition still exists do not continue operation and contact manufacturer for technical service immediately CAUTION Protective Ground Refer to Manual Terminal KDS EZFlow 2010 2011 Specifications Protection against electric shock Mode of operation Degree of protection against ingress of fluids Acceptable syringe sizes Flow rate ranges Infusion accuracy Check Operating temperature Relative Humidity Power requirements 110V version Power requirements 220V version Dimensions Weight Battery operation at a flow rate of 50 ml hr assuming fully charged battery 4 hours SYRINGE FLOW RATES Syringe Size ml 20 30
6. kAScientific KDS EZFlow 2010 2011 Micro Infusion Pump User s Manual hr 7 MA fh x Q Er D Co Publication 5616 003 REV A KDS EZFlow 2010 2011 Contents General Information General Safety Summary Specifications Keypad Function Control Panel Keypad Description seen treten nnne Audible and Visual Alarms Operation Instructions Complete Package Contents Storage Parts and Accessories Limited Warranty KDS EZFlow 2010 2011 General Information This Micro Infusion Syringe Pump is a conventional device for research and development labs and universities This Micro Infusion Syringe Pump offers a reliable alternative for fluid control especially suitable for longterm micro fluid and precise injections CAUTION Important User should read this entire manual before operating this micro infusion syringe pump Keep this manual for future reference General Safety Summary WARNINGS 1 Do not use a pump syringe or accessories that show any sign of damage 2 Check the dose calibration switch located on the bottom of the pump every time use a new different size brand syringe User must calibrate the pump before use to insure the accuracy of infusion 3 Only authorized service personnel should repair this pump Manufacturer assumes no responsibility for incidents that occur if the pump is not repaired according to manufacturer authorized procedures A Befor
7. lay If ERR shows on the display the pump did not pass the power on test and should not be used until the malfunction is corrected Press Number Set Key up amp down arrows to set desired flow rate Load syringe with desired fluid Lift up the Syringe Securing Bar and rotate right 90 Place the syringe into the bed Be sure to insert the nozzle into the syringe slot Then press the release button on the plunger driver block and slide the driver block into position so that the end of the syringe plunger can be placed into the slot in the driver block Make sure the syringe plunger is properly seated in the plunger driver block Turn the Syringe Securing Bar to the left 90 degrees to secure the syringe barrel Make sure the syringe barrel is secure Press and hold the PURGE button to purge air from the syringe and associated tubing Press RUN to start infusion To reset the total volume delivered power off the pump and restart KDS EZFlow 2010 2011 Complete Package Contents 110 VAC or 220 KDS EZFlow 2010 Power cord mains one piece Storage This product should be stored in an environment with ambient temperature range of 14 F 131 F 10 C 55 C relative humidity below 93 and air pressure 500hpa 1060hpa Do not store close to corrosive vapor and or harmful materials Wess Terme 50780 20 STD STD IMPORTANT CALIBRATE FOR DIFFERENT SYRINGE CHECK THE DOSE CALIBRATION SWITCH LOCATED
8. so the above limitation may not apply to you If a defect arises within the warranty period contact KD Scientific Inc see address below The customer is responsible for shipping charges and must first obtain a Return Material Authorization number RMA before the unit will be accepted If a replacement unit is issued it is covered only for the remainder of the original warranty period dating from the purchase of the original device This warranty gives you specific legal rights You may also have other rights which vary from state to state KD Scientific Inc 84 October Hill Road Holliston MA 01746 Phone 508 429 6809 Fax 508 893 0160 E mail info kdscientific com Web www kdscientific com kd Scientific Copyright 2009 by KD Scientific Inc All rights reserved Printed in USA 8