Home

Installation Manual PAL Driver2_3_3 for Empower

image

Contents

1. Nt i Rra Ea ee aT ia ay T Chromatographic System GC System Properties General Configuration Access Drag Components to from the System Configuration list to alter its configuration Note that you may open the other systems and move their components also Available Components System Configuration ctePALHE76543 fal A SS0HS3 76554 dl PAL Support coos Heo This feature is not available when the CTC PAL is used in combination with the Agilent 6890 GC or the Agilent 7890 GC with Agilent Instrument Control Software v2 5 and up Instrument Control Software v2 01 is supporting this feature controlled by Empower The reason for this is how the Agilent 6890 and 7890 Is integrated and controlled by Empower 8 2 Cycle Editor not available on an Empower Client Cycles are the base of all methods They contain the individual commands of the CTC PAL The Cycle Editor is located in the Tools menu of the Configuration Manager Cycles can only be edited on the PC that is physically connected to the PAL This is because Empower is unable to store and distribute Cycles 8 3 Editing Methods in Browse Projects Editing methods that were created with earlier versions of the product version 2 3 0 or earlier is not possible in Browse Projects before converting the method to a newer structure PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A S
2. PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual B Table of Content A Printing History 2 B Table of Content 3 1 INTRODUCTION 5 1 1 General 5 1 2 About Screen Shots 5 1 3 Default Behavior 5 2 LICENSING PACKAGING AND DEPLOYMENT 6 3 SUPPORTED CONFIGURATIONS 7 4 SOFTWARE INSTALLATION 8 4 1 System Requirements 8 Hardware and software requirements 8 4 2 Tested Configurations 8 4 3 Installation Instructions 8 Installing the software 8 Uninstalling the software 9 4 4 Trademarks 9 5 EMPOWER CONFIGURATION 10 5 1 Configuration Manager 10 5 2 Empower Nodes 11 5 3 Configuration Manager Dialog for use with serial port 11 5 4 Configuration Manager Dialog for use with TCP IP 13 Obtain TCP IP Settings from the Waters DHCP server 13 Fixed TCP IP Settings 17 5 5 New Chromatographic System 19 Create New System 19 Connect to Existing System 19 Add instruments 20 Access Control 21 Name Selection 22 5 6 Plates 23 Define plate type VT32 23 Define plate type VT98 24 Configure Plates 25 6 FIRST USE 26 6 1 Configure for use with multiple plates 26 7 POINTS YOU NEED TO KNOW 27 7 1 Prerequisite 27 PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 7 2 CTC PAL setup 27 7 3 PAL in combination with Agilent GC s 27 7 4 Examples 28 8 KNOWN LIMITATIONS 30 8 1 Overlapped injecti
3. the following screen will appear Empower Node Dve paul ym1 Properties OF Cancel Help On some systems the OK value will be No at first The reason may be that the instrument is not yet initialized The value should change to Yes by pressing Scan Instruments after a few seconds PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 5 4 Configuration Manager Dialog for use with TCP IP The CTC PAL this applies just for PAL xt firmware 4 1 x and higher with LAN interface can be configured to have fixed TCP IP settings or to obtain them from a DHCP server Waters Empower includes a DHCP server Obtain TCP IP Settings from the Waters DHCP server Select tab Configure DHCP and click button Configure DHCP Empower Node Dve paul ym1 Properties General Instruments Serial Ports Configure DHCP Access The Waters DHCP Server is designed to work automatically without user Intervention Gut in some cazes you Will need to change or specify DHCP settings for the instrument network or third party instruments in your laboratory Click the button below to configure third party Ethernet instruments on this Empower node or to use a different IF address range for your Instrument network Select menu item Server gt Configuration Wizard i Waters DHCP Server Configuration Fie Ena Help Configuration Wizard I
4. A7890 and PAL QuickStart gt View Method gt PAL Q Untitled in Defaults as System Administrator QuickStart View Instrument Method File View Manage Help Run Samples iihi Available Cycles Cycle Arguments GC ri Sample Queue 5 Air Volume ud piaia Pre Clean with Solvent 1 Control Panel ioui v Pre Clean with Solvent 2 i one Pre Clean with Sample r Description Browse Project i Filing Speed l s Filling Strokes Inject to View Data Injection Speed pls Pre Inject Delay ms Post Inject Delay ms Post Clean with Solvent 1 View Method ET Post Clean with Solvent 2 Method Set Instrument mooo g al EA a a Processing Show Me View Acquisition ie se E E i 3 00 4 00 5 00 6 00 7 00 Minutes Meth Set Untitled lInst Meth Untitled PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 8 KNOWN LIMITATIONS 8 1 Overlapped injection As of now time optimization for overlapped injections is limited to two samples This can be achieved by building a method based on the cycle named HS_2 Vial Overlap Sample lists should only contain methods based on overlap cycles The order of instruments within the system configuration should always have the preparing instrument before the analyzing instrument please see example below
5. PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 3 SUPPORTED CONFIGURATIONS The software is designed for use with Empower 3 Build 3471 Feature Release 2 and higher for more details see 4 2 Tested Configurations PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 4 SOFTWARE INSTALLATION 4 1 System Requirements Before you install the CTC PAL Control for Empower note these hardware and software requirements and the information about the PAL environment Hardware and software requirements The following table lists the basic computer requirements necessary for the various Empower 3 nodes For further details please see the Empower 3 Basic Computer and Installation Requirements documentation Parameter Personal Client or Windows Database Citrix Server Workstation LAC E Server XenApp Server 6 0 Memory 2 GB 4GB 2GB minimum Hard Drive 25 20 27 22 Total Free GB minimum Core Duo Core Duo Intel Xeon 2 GHz single minimum E6400 E6400 or dual Operating Windows 7 Windows 7 Windows Server 2008 Windows Server System 64 bit 64 bit R2 Enterprise 64 bit 2008 R2 Professional Professional Enterprise 64 bit or Enterprise or Windows XP 32 bit Professional or Enterprise Oracle Oracle 11g none Oracle 11g R2 64 bit none Oracle 11g Oracle 11g R2 32 bit Oracle 11g R2 32 R2 32 bit R2 32 bit bit Internet
6. 8 0 8 0 8 0 8 0 ___Explorer 4 2 Tested Configurations The CTC PAL Control for Empower has been tested on these configurations Microsoft Windows 7 Professional Service Pack 1 English versions Citrix Server Empower 3 Feature Release 2 FR2 CTC PAL xt standalone firmware 4 3 0 2 5 2 4 3 Installation Instructions In this procedure you will run the self installing executable to unpack and install the CTC PAL Driver for Waters Empower CDS software bundle Installing the software Note e You must have administrative permission in order to install the software on Microsoft Windows 7 e Previous versions e g v2 1 0 must be uninstalled first see Uninstalling the software PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Run Setup exe to start the installer application InstallShield Wizard will be displayed Follow the instructions the installer provides The installer may ask you to reboot your computer Uninstalling the software To uninstall the software e Navigate to the Add Remove Programs tool in the Windows Control Panel e Click CTC PAL Driver for Waters Empower CDS in the list e Click Change Remove 4 4 Trademarks PAL Is a trademark of CTC Analytics AG Microsoft Windows 7 and the Windows logo are trademarks of Microsoft Corporation in the United States or other countries or both Oth
7. CTC PAL Control for Waters Emp3 CDS PDA SYSTEM Installation Manual CTC PAL Control for Waters Empower 3 Software Revision 2 3 3 Installation Manual CTC Analytics AG reserves the right to make improvements and or changes to the product described at any time without notice CTC Analytics AG makes no warranty of any kind with regard to this product including but not limited to implied warranties of merchantability and suitability for a particular purpose In no case shall CTC Analytics AG be liable for any coincidental or consequential damage in connection with or arising from the use of this document 2011 2014 CTC Analytics AG All rights reserved Neither this publication nor any part hereof may be copied photocopied reproduced translated or reduced to electronic medium or machine readable form without the prior written permission of CTC Analytics AG except as allowed under copyright laws CTC Analytics AG acknowledges all trade names and trademarks used as the property of their respective owners PAL is a registered trademark of CTC Analytics AG Switzerland systen A Printing History Edition Date Edition 4 December 2014 Edition3 June 2014 Edition2 June 2014 Edition April 2011 CTC PAL Control for Waters Emp3 CDS Installation Manual Reason for Change Product version 2 3 3 Release Product version 2 3 1 Release Update as to Feature Release 2 improvement concerning client support Empower 3 support
8. MAC Address Configuration Errors PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Select Network Connection the PAL is connected to Select Network Connection IF Address es Local Area Connection 2 192 165 0 1 64 1 1 1 Local 4rea Connection 192 165 1 56 e Click Next 2x and Finish Restart system when asked e Start Empower and open Configuration manager e Turn on the PAL confirm that PAL communication Is set to LAN and DHCP to On this applies just for PAL x firmware 4 1 x and higher for detailed information please see CTC PAL User Manual Edition 4 and higher section 8 2 9 2 Setting up LAN Communication e Open properties of the Empower node e Select tab Configure DHCP and click button Configure DHCP e Connected PAL will appear in DHCP Server Configuration window i Waters DHCP Server Configuration Ba File Server Help IF Address MAC Address Mame 192 168 0 2 O0 70 44 B4 35 5E CBA355E PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Select PAL and click Edit Select ctcPAL in Instrument Type Edit IP Address IF Address MAT Address Instrument Type Serial Number CBASSSE Unique Mame a Click OK Confirm that the Instrument Type Is set to ctcPAL i Waters DHCP Server Configuration Fie Server Help I
9. P Address MAT Address Type Name 192 168 0 2 O0 20 44 B4 35 5E ckcP AL CBA355E Click OK PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual When switching to the Instruments tab the following screen will appear Empower Node Dve paul vm1 Properties General Instruments Serial Forts Configure DHCP Access OK Cancel Help On some systems the OK value will be No at first The reason may be that the instrument is not yet initialized The value should change to Yes by pressing Scan Instruments after a few seconds PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Fixed TCP IP Settings Confirm that PAL communication is set to LAN and DHCP to Off this applies just for PAL xt firmware 4 1 x and higher for detailed information please see CTC PAL User Manual Edition 4 and higher section 8 2 9 2 Setting up LAN Communication Select tab Configure DHCP and click button Configure DHCP Click Add in the DHCP Server Configuration Set IP Address to IP set on the PAL set a fake MAC Address select Instrument Type ctcPAL and set a Unique Name Add IP Address IF Address 192 10d Mac ate aiaia Instrument Type cbcP AL Serial Mumber PHO637R Unigue Mame Click OK PAL Instrument is added in DHCP Se
10. YSTEM Installation Manual This conversion can be achieved by starting Run Samples for the instrument the method was intended for Make sure the Control Panel Status Is green and displays Ready Now open the method save it and close tt When editing a method in Run Samples always make sure It is opened for the correct instrument because the method will only work for this instrument or an Instrument that Is configured identically once it s saved PAL is a registered trademark of CTC Analytics AG Switzerland
11. c Signals are inputs that tell the PAL when to wait or proceed with a sample processing step Output Signals Out Signals are sent from the PAL to external devices In combination with Agilent instruments e g A7890 A6890 A1100 etc the PAL Cycle events require the following setup e Start Sync Signal gt TTL In1 e Injected Out Signal gt SW Outl e Remaining Sync Signals gt Immediate Ignore e Remaining Out Signals gt Off To assign this physical event e g SW Out1 to an existing signal object Injected complete the following menu selections on the PAL e Menu gt Setup gt Objects gt Out Signals gt Injected gt Destination gt SW Outl 7 3 PAL in combination with Agilent GC s Agilent 7890 The Setting Tab for the Injectors has to be set to None see below Otherwise the system would indicate an Agilent autosampler is configured while there is no autosampler present Empower would respond with an Instrument Failure Empower Message Center gt the injector configured in the method is not present A7890 standalone TestME in Defaults as System Administrator QuickStart View Instrument Method Eile view Manage Help Run Samples s m Settings Oven Events Valves Auxiliary Channel 1 Column 1 Front Inlet Sample Queue Control Panel V Column 1 Inlet Front z Outlet None x D Column 2 Inlet N ne Outlet fi G Injector Browse Project E View Data view Meth
12. d up to 30 alphanumeric characters is needed to access the selected chromatographic system across databases Confirm Password Requires re entry of the password to confirm that it was spelled correctly PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Allow Access to Group s Select the user group s that you want to give access to the selected chromatographic system Access privileges of these user groups override access privileges of the selected world user type If you select Owner Group and World groups that were not selected in the Allow Access to Groups list are assigned the World User Type Access Name Selection Use this page to name the new chromatographic system and enter any optional comments New Chromatographic System Wizard Name Selection T 5 Sustem Name gA GC Lab d Acquistion ServerName wimp iY Online System Comment H Back Cancel Help System Name Identifies the chromatographic system in the Empower database and in Configuration Manager Up to 30 alphanumeric characters are allowed for the system name Use a meaningful system name in case other users have access to the system Empower Node Name Name of the Empower Node to which the selected system is connected This field is not editable If all configured system instruments are available not configured in another online system this bring
13. des The name up to 15 alphanumeric characters assigned to a device on a network the first character must be a letter Use a name such as the location of the Network LAC E that identifies the node as a Network LAC E The node name must be the name assigned to the Network LAC E during installation also known as computer name You use the instruments connected to Empower Nodes to create chromatographic systems Managing Empower Nodes involves several tasks for setting up the CTC PAL The menu item File gt New or right click Properties brings you to the configuration Manager Dialog 5 3 Configuration Manager Dialog for use with serial port Confirm that PAL communication is set to SER this applies just for PAL xt firmware 4 1 x and higher for detailed information please see CTC PAL User Manual Edition 4 and higher section 8 1 9 1 Com Port Settings Use this tab to select the serial port the PAL is attached to Empower Node Dve paul ym1 Properties General Instruments Seral Ports Configure DHCF Access BusLAC E Seral Ports o Fort Serial Card Fort 1 None Fort 1 o Fort 2 None Port 2 o pot None Port 3 Port 4 None PC Serial Ports Port 4 Port 4 coh None Fort COM Port 7 COM4 Fort amp Cancel Help PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual When switching to the Instruments tab
14. er company product and service names may be trademarks or service marks of others PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 5 EMPOWER CONFIGURATION This window is part of Empower and is used to access the primary applications in Empower software Applications started from here are assigned to the current user Note Configuring the system requires administrative rights E Empower Pro w a B 2 User System Tomm cosaur feaur mep PP Loeal Run Samples Browse Project Configure System Process Data Review Data Print Data Pressing the Configure System button will pop up the Configuration manager 5 1 Configuration Manager To configure the CTC PAL we have to configure an Empower Node and at least one System S System Administrator Configuration Manager Fie Edit view Records Tools Help Saa l x rM E Fiter By Defaut v _EdtView Update amp Empower Configuration i Erecwer Rode Name Empower Nove Type Owner Empower Node Comments Ma rojet 1 Dve trido vmt Empower System 3 Systems ee A ca Libraries Users User Groups User Types amp Plate Types 75 System Audit Trail Offline System Audit Trail For Help press F1 PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 5 2 Empower No
15. ll vial Plate Rows and Columns Referencing Plate Type Format xv Plate Dimensions mm Height x Y f 10 00 a 6 00 30 00 m Well Dimensions mm x Y Top Left Well Location 2 00 8 00 Diameter Depth Well Size fi 2 00 20 00 Cancel Plate Rows and Columns Referencing r Row and Column Dimensions mm Number Spacing Rows 14 Columns f Row and Column Offsets mm None Row Offset C Odd C Even None Column Offset C Odd C Even PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Plate Rows and Columns Referencing Origin Origin TopLeft Top Right C BottomLeft Bottom Right Scheme Referencing XY Sequential is CI CI fis Sequential Continuous Horizontal First Priority Terminology Plate Tray Well Vial gt Cancel Help Configure Plates Before you select the correct plates in Empower you need to know the names of the trays and their configured tray types in the PAL itself This information can be gathered through the CTC PAL Control panel PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 6 FIRST USE 6 1 Configure for use with multiple plates By default Empower is not configured to work with multiple plate
16. od ET Method Set aga srl 2 ee or is System Idle Instrument Failure 0 20 gt 0 00 7B 0 00 1 00 2 00 3 00 4 00 5 00 6 00 7 00 EE Minutes Meth Set 47890 standalone TestME Inst Meth A7890 standalone TestME PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS Installation Manual systen Agilent 6890 The same applies here the General Tab should have the Front Injector and Back Injector disabled see below Otherwise the system would indicate an Agilent autosampler is configured while there is no autosampler present Empower would respond with an Instrument Failure Empower Message Center gt the injector configured in the method Is not present Q Untitled in Defaults as System Administrator QuickStart View Instrument Method File View Manage Help iid Run Samples Front Detector Channel 1 Back Injector Back Inlet Column 2 Back Detector Channel 2 Sante Queue General Oven Ausiliay Events Valves FrontInjector Frontinlet Column Control Panel Configuration Front Inlet Type s s EPC z Back Inlet Type None Front Detector Type FID x Back Detector Type None gt Browse Project teh View Data r Enable View Method S Method Set Instrument I Front Injector IV Front Inlet M Column 1 Back Injector I Back Inlet T Column 2 Processing IV Front Detector I Back De
17. on 30 8 2 Cycle Editor not available on an Empower Client 30 8 3 Editing Methods in Browse Projects 30 PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 1 INTRODUCTION 1 1 General This document describes the configuration of the CTC PAL in Empower 1 2 About Screen Shots Bitmaps of windows in this document may differ slightly from the software due to bug fixing changes in functionality updated graphical interface etc Where these discrepancies exist the version of the image in the software will take precedence 1 3 Default Behavior This software is an instrument control add on to Empower As such where a software behavior or feature is not described in this document it can be assumed to be similar to the behavior or feature for other third party instrument drivers PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 2 LICENSING PACKAGING AND DEPLOYMENT This instrument control module will be packaged as an instrument control add on The instrument control module will be installed as an addition to the base software and should be installed on the Empower Node and all Empower clients that will use the instrument There s no need to install the module on the Empower database server PAL is a registered trademark of CTC Analytics AG Switzerland CTC
18. raphic system to acquire and process data and to generate reports PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Add instruments Use this page to add instruments to a new chromatographic system New Chromatographic System Wizard System Selection Drag desired instruments from the Available Instruments list to the Hew System Instruments list PF Note ou may open existing Systems and drag instruments to the Slew Spstem Instrumente list Available Instruments Hew System Instruments Unused Components E New System Cancel Help 1 Select an instrument from the Available Instruments list and drag it to the New System Instruments list You can use instruments from the Unused Components and an existing system If the instrument Is not in the Available Instruments list click Cancel and check the properties of the Empower Node 2 Click Next Note You cannot drag the last instrument from an existing system To free up the last instrument on a system delete the system Use this page to control how other users access the new system you are creating You can share the system with other network users and password protect the system Note If you have access to a chromatographic system you do not need to enter the password unless you are crossing databases PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Con
19. rver Configuration i Waters DHCP Server Configuration File Server Help IP Address MAT Address Type Name 192 165 0 100 FF FF FF FF FF FF ctcPAL PHO63 R Click OK When switching to the Instruments tab the following screen will appear PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual Empower Node Dve paul vm1 Properties On some systems the OK value will be No at first The reason may be that the instrument is not yet initialized The value should change to Yes by pressing Scan Instruments after a few seconds PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 5 5 New Chromatographic System New Chromatographic System Wizard Type Entry Choose to define anew chromatographic system orto connect toa system which already exists r System Type C Connect to Existing System Cancel Help Create New System Specifies that you create a new chromatographic system using available instruments connected to an Empower Node The system might not be directly connected to your Empower Personal workstation Connect to Existing System Specifies that the current user can access the selected chromatographic system If the system Is password protected you need the password to access the system Then you can use the chromatog
20. s the new system online Default selected System Comment Displays optional remarks up to 250 characters Comments that describe the chromatographic system its components and Its intended use can help others if they have access to the system PAL is a registered trademark of CTC Analytics AG Switzerland systen 5 6 Plates CTC PAL Control for Waters Emp3 CDS Installation Manual The following sections show the properties of the most commonly used CTC tray types the VT32 and VT98 Defining plate type can be done from the QuickSet QuickStart and Configuration Manager Define plate type VT32 Plate Rows and Columns Referencing Plate Type Name se Format xv Plate Dimensions mi Height m x v f 10 00 21 7 00 30 00 Well Dimensions mm x Te Top Left Well Location 14 0 14 00 Depth Well Size 23 20 00 Row and Column Offsets mm None Row Offset C Odd C Even None Column Offset C Odd CE PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS Installation Manual Plate Rows and Columns Referencing m Origin Origin TopLeft Top Right C Bottom Left Bottom Right Scheme Referencing XY Sequential Horizontal EAB Cin e eae Vertical Pinta Sele oL I Sequential Continuous I Horizontal First Priority gt Terminology Plate Tray We
21. s trays In this the case the system will default to 7ray1 which must be present in the PAL To work with the plates defined in section 5 6 open the Empower QuickStart or QuickSet interface and select the menu item Edit gt Plates The following screen will appear Define Plates For Sample Set Method Seat Plis 1 Uncheck the 2790 Layout checkbox 2 Click on the Plate Type Name of the first row and select a VT32 plate 3 Click on the Plate Layout Position of the first row and enter name of the VT32 tray as configured in the PAL By default Tray1 or Tray2 4 Repeat previous steps for a VT98 tray Define Plates For Sample Set Method gt s Create New Plate Type Clear Plates Plate Sequencing Mode I f Plate Type Name Plate Layout Position Tray2 Tray memene T98 Ae E M E O E P ooo A ooo S Oo o e Caci Hep mee e To select sample locations select a plate click on the vials in the right pane and push the Insert or Append button PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual 7 POINTS YOU NEED TO KNOW 7 1 Prerequisite e Networking cable RJ45 or RS232 cable PC 9pf 9pf delivered with the PAL xt CTC Article no RS9B 3000 e Agilent remote cable for A7890 A6890 A1100 CTC Article no Cbl 7890 7 2 CTC PAL setup Synchronization Signals Syn
22. tector N Channel 1 Show Me View Acquisition 0 40 0 60 Minutes For Help press F1 Meth Set Untitled Inst Meth Untitled 7 4 Examples A7890 and PAL QuickStart gt Run Samples gt Control Panel A7890 and PAL in Defaults as System Administrator QuickStart Run Samples TAR File Edit View Inject Actions Customize Manage Help 5 fea a il oi Run Samples iii Sample Queue Browse Project ey uA i ka A7890 6 Run Only Continue on Fault Apply Table Preferences S ample AF eh Om Control Panel 2 00 3 00 4 00 5 00 Minutes View Data Fr Syringe ul 0 0 Bk Syringe ul Aux 1 ND System Ready V1 ND Y2 ND view Method ET Oven 200 00 C 199 99 Inlet 1 1 00 mlimin 101 02 Method Set Instrument Inlet 1 250 00 C 250 00 Inlet 1 97 00 kPa 97 00 Aux 2 NI Inlet 2 50 00 C 171 57 Inlet 2 1 00 ml min 0 0 0 02 Aux 3 ND Y3 NI Processing Det 1 300 00 C 300 00 Inlet 2 68 95 kPa Det 1 pA V4 ND Det 2 0 0 C 0 0 Aux 1 Therm 0 0 C 0 0 Det 20 V5 NI Det 3 0 0 C 0 0 Aux 2 Therm 0 0 C 0 0 Det 30 6 NI Show Me View Acquisition Status READY Details Traye Trapt Vial 3 Error Connect lt Feini PAL is a registered trademark of CTC Analytics AG Switzerland CTC PAL Control for Waters Emp3 CDS A SYSTEM Installation Manual
23. trol for Waters Emp3 CDS A SYSTEM Installation Manual Access Control New Chromatographic System Wizard Access Control i Share System with Other Network Users Allow Access to Groupls Allowed Access C Owrer Only C Owner and Groups IL Administrators Tia k a a lauests f Owner Group and World Password Protect System Access Share System with Other Network Users Specifies that other network users determined by the access option you select see below can use the system If you select this option consider password protecting the system to limit its use to authorized users Allowed Access Owner Only Specifies that the owner of the chromatographic system and users with Administrator privileges can access the selected chromatographic system Owner and Group s Specifies the owner of the chromatographic system group members as specified in the Allow Access to Groups list and administrators can access the selected system Group access only allows a user to operate a chromatographic system Note To modify a chromatographic system you need access to the chromatographic system and its Empower Node Owner Group and World This field specifies that all users in the database can operate the selected chromatographic system Password Required This field specifies that users enter a password before they can access the selected chromatographic system across databases Password Specifies a passwor