Home
Micron Scorpion Z16040C alarm
Contents
1. Arming the System by Area Enter the quick key command for the selected area Ci 1 area A armed 2 area B armed 3 area C armed 4 area D armed 10 Quick Arming All System Areas Enter the quick key command to arm all disarmed areas Ta 9 arms all disarmed areas Arm or Disarm All Areas or Disarm Selected Areas Partitioned System The Scorpion Z16040C can be partitioned into a maximum of four separate areas These partitions can be managed as independently alarmed areas Enter a valid code to arm all areas disarm all areas or disarm selected areas Cr lt enabled user code gt arms or disarms all areas lt enabled user code gt 1 disarms area A lt enabled user code gt 2 disarms area B lt enabled user code gt 3 disarms area C lt enabled user code gt 4 disarms area D Night Arming Delayed Night arming allows areas such as upstairs bedrooms to remain disarmed while all downstairs zones are armed Enter the night arming code for the selected area as 91 night arms area A 92 night arms area B 93 night arms area C 94 night arms area D When a night arming code is entered the keypad will emit a two beep arming confirmation and display the pre programmed night zones The moon symbol will appear and the padlock and area identifier will flash The system is now undertaking a silent delayed arming routine allowing the user to exit through t
2. Security Products Ltd 30 32 Crummer Road PO Box 78 006 Grey Lynn Auckland New Zealand Phone 64 9 378 6098 Facsimile 64 9 378 6454 Email info micronsecurity com www micronsecurity com
3. these two key commands will activate an audible alarm and if monitored send a signal to your monitoring station to action a response to the call 20 Other Micron Products itewatch Night Arming Station Nitewatch is an essential accessory to all micron alarm installations for perimeter arming and a panic function at the bedside RCM24 Mega Rolling Code Receiver Allows micron alarm controls to be remote armed and disarmed and with remote panic function Also enables garage door lighting or gate control Mini Micro Siren Composite Mini micro s intelligent microprocessor circuitry can be programmed to produce both burglary and fire sounds Sirens are with either a red or blue lens 21 PXI Pet Exclusion Infrared Sensors PXI has intelligent pet exclusion analysis to provide a very cost effective pet sensor that enables animals to be left inside alarmed premises BG2000 Glass Break Sensor This low profile glass break sensor provides a large 2000 square foot coverage and activates an Speech Dialler Micron s speech dialler can be programmed to call telephones mobile phones or pagers with multiple speech messages that advise of alarm conditions Medical Emergency Response ER 1 is a reliable and flexible medical emergency reporting system for up to sixteen users The compact console is easy to operate for the elderly and infirm with universal symbols for each button s functionality EzeKey a
4. zone s will resume chime monitoring and will again sound an alert tone if further activity is detected When turning off the chime function the keypad will emit a two beep tone Add a New User Code co 20 lt master user code gt lt new user code gt New user codes will be automatically written to the next available location Scorpion Z16040C has a maximum of 48 user codes Change an Existing User Code Eo 21 lt master user code gt lt old user code gt lt new user code gt The new user code will automatically overwrite the old one All parameters for the new code will remain the same as the old code Delete a User Code bias 23 lt master user code gt lt user code to delete gt Enter a Temporary User Code i 24 lt master user code gt lt temporary user code gt Temporary user codes allow access to the secured property for one day The code is deleted by the system at midnight the same day Enter a Follow Me Telephone Number call diversion The alarm control may be programmed by the end user to divert an alarm condition call to one or two temporary telephone numbers OF 31 lt master user code gt lt follow me telephone number 1 gt 32 lt master user code gt lt follow me telephone number 2 gt The control is pre programmed to enable communication to a personal telephone or mobile phone and sound a warning that the alarm system has activated siren warble A series of beeps after the si
5. SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller Micron product is manufactured to exacting quality standards We understand the importance of designing products that are reliable and easy to use You can rest secure knowing we have thought of everything to ensure your complete peace of mind Adda New User Coders ia ccd voi EAT goede Wt ea S 15 Arm or Disarm All Areas or Disarm Selected Areas Partitioned System 11 Arming the System Away Mode seeseeeeeeeresesesesesrsrsssssessersrsrssererereseseseses 8 Arming the System to Exclude or bypass a Zone s 10 Arming Your System from a Remote Telephone cece eeeseseseeeeseeeeeeseeeeees 13 Auto Arming with no Activity esei ae i e aia ipe e ais 18 Chance Alarms Clock Time seanina A E a 17 Change an Existing User Code ss iiccseccecssnczsseocscnssespseteccuseoeaysueteetisuuss En ain 15 Delete a User Codes cahenrans ain el E R R R a ea 15 Disarming the Systemerne neeo eee aiaiaaeo ees eeraa 9 Dis rming Under Duress 7314 2 Ae ee e ee elie a E e 9 Disarming Your System from a Remote Telephone ta 113 Enter a Follow Me Telephone Number call diversion cccsceseeeeeeeeeeeeees 16 Enter a Temporary User Code t Ar nenne eiie ea 16 Enter Auto Arming TIM seih eea terane a a a a ai 17 Enter Auto Disarming TiMessessseserciciiis iiini i 17 Initiate a Test Call to a Follow M
6. at the lower right hand side of the LCD CID display This symbol displays the area s that is away armed or night armed In non partitioned systems only Area A is displayed Zone and Graphic LCD keypad Indicators The zone indicator lamps are displayed as numbers 1 through 16 on the top two lines of the LCD keypad The arming zone numbers will be displayed when an away arm or night arm command has been initiated During the exit delay the keypad will also display the padlock symbol flashing in an alternating lock and unlock state and the area identifier box will show the area s that are arming A fast pulse audible tone will be heard In the event of a system alarm the keypad will display the full status of the alarm condition The zone indicators power lead system fault bell and padlock symbols will flash together with the area identifier indicating the area in which the zone s has activated If your system is partitioned into multiple areas then only the user codes assigned to the designated area s are functional for that area s All zones assigned to an area are visually and audibly signalled on the keypad s programmed for that area s The Sixteen Zone LED Keypad The LED keypad gives full visual and audible indication of the status of your alarm The keypad has four area identifiers AC power night arm and 16 zone indicators The green AC symbol is on when mains power is present and flashes when there has been a mains failur
7. back within 60 seconds The alarm will automatically answer on the first ring with a high low tone acknowledgement Now enter the sequence to turn on an output This output could be used to turn on heating or lights for example Ta 5 lt enabled user code gt If the output is already turned on a long beep will be heard Turning Off an Output from a Remote Telephone Dial the alarm s telephone number and wait for two rings hang up the telephone and call back within 60 seconds The alarm will automatically answer on the first ring with a high low tone acknowledgement Now enter the sequence to turn off an output This output could be used to turn off heating or lights for example F 7 lt enabled user code gt If the output is already turned off a long beep will be heard System Chime wa 71 area A chime on or off 72 area B chime on or off 73 area C chime on or off 74 area D chime on or off 14 When the system is disarmed entering one of the 7 commands will turn chime mode on or off When turning chime mode on the keypad will emit a three second series of beeps When one of the pre programmed chime zones is activated such as a door entrance an alert tone will sound at the keypad alerting that someone has entered the chime zone area After the initial chime alert chime mode sleeps and waits for no activity within that zone area If after 30 seconds no further activity has been detected the chime
8. begin arming and the keypad will emit a tone for the programmed exit time At the expiry of the exit time the tone will stop and the system will arm Visual and audible indication of the alarm status will be displayed on the keypad Please refer to the LCD graphic and LED symbol descriptions below When entering the premises the keypad will emit a repeating tone for the programmed entry time alerting you to turn off your alarm system Entering a valid user code will disarm the system and the keypad will emit two short beeps An incorrect user code entry is signalled by one long beep Icon LCD Keypad Symbols The LCD keypad gives full visual and audible indication of the status of your alarm The keypad has five graphic symbols an area identifier and 16 zone indicators Te The power lead symbol is on when mains power is present and flashes together with the system fault symbol when there has been a mains failure A The system fault symbol flashes when there has been a system fault condition or a system two key panic command has been initiated see page 20 for further details The bell symbol flashes when an alarm condition has occurred or a system two key panic has been activated The moon symbol is displayed when the system is night armed The padlock symbol is displayed unlocked when the system is disarmed and locked when the system is away armed or night armed AJB The area identifier symbol is the four segment box
9. e The AC symbol flashes fast when there has been a system fault condition or a system two key panic command has been initiated see page 20 for further details The area identifiers S1 S2 S3 S4 flash when arming an area s and remain steady on when an area has armed The area identifiers S1 S2 S3 S4 flash when an alarm condition has occurred within that area s or a system two key panic has been activated The yellow Nite symbol is on when the system is night armed Zone LED Keypad Indicators The zone indicator lamps are displayed as numbers 1 through 16 on the LED keypad The arming zones will be displayed when an away arm or night arm command has been initiated A fast pulse audible tone will be heard In the event of a system alarm the keypad will display the full status of the alarm condition The zone indicators will flash together with the area identifier indicating the area in which the zone s has activated If your system is partitioned into multiple areas then only the user codes assigned to the designated area s are functional for that area s All zones assigned to an area are visually and audibly signalled on the keypad s programmed for that area s 5 Keypad and Telephone Entry Commands Table Commands notated lt gt indicate a numeric code to be entered on the keypad to execute that function i QuickarmareaA o O 2 QuickarmareaB o O e t 1 lt enabled user code gt Area armed using a touc
10. e Telephone Numbet 0 cccecseseseeseereneees 16 Keypad and Telephone Entry Commands Table eee ecceeseeeeseeeeeereeeeeees 6 Miscellaneous Alarm Recall ececeseesesesseeseseeseeecseesesesscesseesesesseeesseeaeeesaeees 19 Night Arming Delayed escent AM Night Arming Instant icccceissc cscs cecesancetec cavesees rine secsause Aeesbenneat us aE 12 Quick Arming All System Areas meee i Quick Arming the System by Area eeceeeseeseeecseeseeesceesseescsessceesseeseeesaeees 10 Stop Current Communication 2 1 02 dee anita a ah 18 System Chime ense nates vsdibers AA Meas A eee OR 14 Tamper Alarm Recall iriiri niina Seatac eee nets 19 The Icon LED Keypads aescn monn a E T TEREE 3 The Sixteen Zone LED Keypad aeaea aerar oara aa AE RT 5 Turning Off an Output from a Remote Telephone sssessssssssersrssesrsrrrsrsrsrereee 14 Turning On an Output from a Remote Telephone seeeseeeeereresereresesrrrrrsrsree 14 Two Key Panic Fire and Medical Alert Je 20 User Code Commands rarena n asain awe etalas canna 8 Walk Test Modenu di aan sens aaan o stetas debe tabs ca tenes lop EE a EAEE EO AE 20 Zone Alarm History Recall eiia roei resiente heieren 18 Other Micron Products voas 2seseccad iniit eee E E E AA A OOR E ETAR 21 The Icon LCD Keypad The Scorpion Z16040C indicates system status by visual and audible indication via a sixteen zone Icon LCD or LED keypad When a valid user code is entered the alarm will
11. h tone phone For areas A D 3 lt enabled user code gt Area disarmed using a touch tone phone For areas A D 5 lt enabled user code gt Output turned on using a touch tone phone 7 lt enabled user code gt Output turned off using a touch tone phone phone number from a touch tone phone and Arm all areas or arm all areas not already armed ae A E a ee E ee ee ee 6 lt master user code gt lt auto arm time HHMM gt 24 hour format lt master user code gt lt auto disarm time HHMM gt 24 hour format lt master user code gt To abort current communications Ooo Dc ae a ee ee i i Nite arm disarm area A Nite arm disarm area B Nite arm disarm area C Nite arm disarm area D Instant Nite arm area A In Instant mode you can only disarm using a valid user code Instant Nite arm area B In Instant mode you can only disarm using a valid user code Instant Nite arm area C In Instant mode you can only disarm using a valid user code Instant Nite arm area D In Instant mode you can only disarm using a valid user code Two key panic Press both keys simultaneously Fire panic Press both keys simultaneously Medical panic Press both keys simultaneously User Code Commands User codes can be set up to function in a number of different ways Each user code may be assigned with multiple functions Please refer to the table below Discuss with your installer how you would like your user codes to fu
12. he protected night armed areas After the pre programmed delayed exit time has expired the night zone s indicators will turn off and the area identifier will stay on solid Your system is now night armed When entering a night zone protected area the keypad if programmed to do so will emit an audible tone alerting the user to disarm the system with a valid user code If after the pre alert the system has not been disarmed an alarm condition will occur If one or more of the night zone s indicators is flashing during night arming and the keypad is sounding an alert tone the system is indicating that a night zone s is in an unsecured state eg an open door The system should be disarmed using a valid code the problem identified corrected and the system re armed To ensure secure system integrity the alarm system can only be disarmed with a valid user code when night armed Night Arming Instant Enter the night arming code for the selected area a 96 night arms area A 97 night arms area B 98 night arms area C 99 night arms area D Instant night arming is identical to delayed night arming with the exception that there is no silent arming delay and the system will arm instantly When entering the night zone s protected area the system will generate an instant alarm In instant mode you can only disarm the system using a valid user code 12 Arming Your System from a Remote Telephone This function requires that you
13. lse After leaving the protected areas the keypad zone indicators will change back to steady and the audible tone will revert back to a fast pulse After the exit delay time the zone indicators will turn off and the audible exit tone will stop The system is now armed Disarming the System On entering the premises the keypad will generate an audible tone reminding the user to turn off the alarm system Enter a valid two to eight digit user code then Bias lt enabled user code gt Disarming Under Duress Enter a valid two to eight digit user code then press and hold the key until a second beep is heard The alarm system will disarm and send a duress code to the central receiving station if the alarm is monitored GF lt enabled user code gt then hold until a second beep is heard Arming the System to Exclude or bypass a Zone s To exclude or bypass zone s enter the following sequence co 11 lt enabled user code gt then lt zone to bypass gt lt zone to bypass gt To exclude zones 3 and 12 prior to arming enter the following sequence es 11 lt enabled user code gt then lt 3 gt lt 12 gt The keypad will now display only those zones that are arming When next disarming your system the bypassed zones will restore to their normal state Only a valid user code with priority to exclude a zone s assigned to the area with zones to bypass can carry out this function see user code commands page 8 Quick
14. nction 1 Arm system only 2 Master user code 3 Disarm all or disarm by area selection 4 Arm Disarm lock code if armed by this code no other valid code can disarm the system 5 Arm Disarm from a touch tone phone 6 Turns output 4 on off from a touch tone phone 7 Bypass zones Arming the System Away Mode Enter a valid two to eight digit user code Factory default user code is 1 2 3 4 Use your programmed personal user code when carrying out keypad commands throughout this manual If your security system is partitioned with zones assigned to different areas then any keypad commands for that partition can only be entered on the keypad assigned to that partition Please discuss this with your installer during commissioning oF lt enabled user code gt then The keypad zone indicators that are arming will be displayed for the duration of the pre programmed exit delay time and then turn off The padlock will be displayed in the locked position and the audible tone will stop If one or more zone indicators are flashing and the audible tone changes from a fast pulse to a slow pulse the system is indicating that those zones are not secure The system should be disarmed the problem identified and corrected and then the system re armed As the user exits through the protected areas the keypad zone indicators for those areas will change from steady to flashing and the audible keypad tone will change from a fast to a slow pu
15. nd EzeProx Access Control Micron access control keypads are a cost effective stand alone access control system for internal doors With 30 user codes and up to 500 proximity cards and tags EzeAccess keypads can control electronic locks on two doors 22 Kocom Intercom Systems The Kocom range of intercom systems offer audio black and white and colour video as well as hands free options for homes and apartment complexes o tu CCTV Solutions Micron s camera and digital video recorder range offer excellent surveillance options for all home and business applications Telecom Waiver The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with the minimum conditions for connection to its network It indicates no endorsement of the product by Telecom nor does it provide any sort of warranty Above all it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model nor does it imply that any product is compatible with all of Telecom s network services This equipment is set up to carry out test calls at pre determined times Such test calls will interrupt any other calls that may be set up on the line at the same time The timing set for such test calls should be discussed with the installer The timing set for test calls from this equipment may be subject to drift If thi
16. r installer has connected a telephone line to the alarm control Dial the alarm s telephone number and wait for two rings hang up the telephone and call back within 60 seconds The alarm will automatically answer on the first ring with a high low tone acknowledgement Now enter the sequence to arm areas an 1 lt enabled user code gt arms the area s assigned to this code The audible exit pre alert will be heard confirming the system is now arming If the system is already in an armed state a long beep will be heard Only an enabled user code assigned to an area can arm that area An enabled user code assigned to ALL areas will arm all areas with one entry Disarming Your System from a Remote Telephone Dial the alarm s telephone number and wait for two rings hang up the telephone and call back within 60 seconds The alarm will automatically answer on the first ring with a high low tone acknowledgement Now enter the sequence to disarm areas CF 3 lt enabled user code gt disarms the area s assigned to this code A two beep confirmation will be heard confirming the system has now disarmed If the system is already disarmed a long beep will be heard Only an enabled user code assigned to an area can disarm that area An enabled user code assigned to ALL areas will disarm all areas with one entry Turning On an Output from a Remote Telephone Dial the alarm s telephone number and wait for two rings hang up the telephone and call
17. ren warble advises which zone s has activated Terminate the call by pressing the key on a DTMF or mobile phone A hang up tone will be heard If the initial call is not acknowledged by pressing the key the panel will search for a secondary number to call Initiate a Test Call to a Follow Me Telephone Number CT 38 lt master user code gt initiates test call to telephone number 1 39 lt master user code gt initiates test call to telephone number 2 After entering a follow me telephone number call diversion this function sends a confirmation test call hi low tone to the temporary number 16 Change Alarm s Clock Time ps 50 lt master user code gt lt enter current clock time HHMM gt 24 hour format Enter Auto Arming Time If your system is partitioned entering an auto arm time can only be activated by a user code assigned to the partition required to auto arm ae 51 lt master user code gt lt enter auto arming time HHMM gt 24 hour format The alarm control will automatically arm at the pre set arming time and will repeat arming at this time every 24 hours If programmed a 5 minute pre alert will sound prior to auto arming Pressing any key on the keypad assigned to that partition during this time will abort the auto arming time until the following day Enter Auto Disarming Time If your system is partitioned entering an auto disarm time can only be activated by a user code assigned to the partition
18. required to auto disarm Eo 52 lt master user code gt lt enter auto disarming time HHMM gt 24 hour format The alarm control will automatically disarm at the pre set time The auto disarming will repeat at this time every 24 hours 17 Auto Arming with no Activity cor No action required by the user If programmed by your alarm technician the alarm will auto arm at the pre programmed no activity time On detecting no activity the alarm will enter a 5 minute arming pre alert To abort auto arming press any key on the keypad assigned to that partition or activate walk through any of the programmed auto arm zones in that partition The auto arming timer will reset and restart the auto arm time with no activity count down Stop Current Communication Entering the following sequence stops the current alarm control communications in progress CF 59 lt master user code gt stops communications in progress Aborts all active communications in progress and clears all outstanding events in reporting history Zone Alarm History Recall Ta 80 recalls alarm event history Step with the key to view zone alarm history History is displayed by the keypad indicator lamps Pressing the key will step back to view past events The first lamp displayed represents the most recent zone alarm A total of 128 alarm events can be recalled Press any key to leave alarm history recall 18 Tamper Alarm Recall a Step with the key
19. s proves to be inconvenient and your calls are interrupted then the problem of timing should be discussed with the equipment installer The matter should NOT be reported as a fault to Telecom Faults Service IMPORTANT This alarm system must be tested weekly to maintain system integrity GUARANTEE Subject to clause 2 below Micron guarantees this product against defects in materials and workmanship for a period of 24 months from the date of delivery to the purchaser as follows a Micron will repair or replace free of charge any goods or part thereof found to be defective by reason of faulty material or workmanship b The purchaser must give Micron notice of the alleged defect within 14 days of it becoming apparent and must return the defective goods or part thereof to Micron This guarantee does not apply or extend to a Any product altered or repaired by any person other than Micron so as in Micron s sole judgement to adversely affect the product b Damage malfunction or failure arising from accident misuse or misapplication neglect modifications use of unauthorised replacement parts or accessories exceeding the specific ratings improper voltage or connection of any wire to any part of the circuit board other than the terminal block c Any product where the rating label or serial number is removed or altered d Any consequential or indirect loss Designed and manufactured by micron security products Micron
20. to view tamper alarm history History is displayed by the keypad indicator lamps Pressing the key will step back to view past events The first lamp displayed represents the most recent tamper alarm A tamper is a protection device connected in sensors and external sirens Press any key to leave tamper alarm recall 81 recalls tamper alarm event history Miscellaneous Alarm Recall as Miscellaneous alarms are associated with internal alarm conditions such as mains power loss low standby battery 83 recalls miscellaneous alarm conditions etc Refer to miscellaneous alarm reports table below LED MISCELLANEOUS ALARM CONDITIONS Led 1 Panic alarm Led 2 Battery is discharged or faulty Led 3 AC mains power to the alarm has failed Led 4 A dialer communication has failed Led 5 Phone line is faulty or disconnected Led 6 Auxiliary 12V power supply overloaded Led 7 Siren output fault Circuit open or overloaded Led 8 Duress initiated from keypad Walk Test Mode eo 85 sets the alarm into walk test mode In walk test mode you can test each detection device without arming the system When a detector is activated in a protected area the siren will generate a short audible confirmation that the detection device has activated Two Key Panic Fire and Medical Alert Press these two key commands simultaneously to activate the following alerts 4 panic alert 4 6 medical alert 1 3 fire alert Pressing