Home

ioLogik E2260 Series User`s Manual

image

Contents

1. The left panel is the navigation panel and contains an expandable menu tree for navigating among the various settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the main window For example if you select Basic Settings in the navigation panel the main window will show a page of basic settings that you can configure You must click the Submit button after making configuration changes The Submit button will be located at the bottom of every page that has configurable settings If you navigate to another page without clicking the Submit button your changes will not be retained Submitted changes will not take effect until they are saved and the ioLogik E2260 is restarted You may save and restart the server in one step by clicking the Save Restart button after you submit a change If you need to make several changes before restarting you may save your changes without restarting by selecting Save Restart in the navigation panel If you restart the 10Logik E2260 without saving your configuration the 10Logik E2260 will discard all submitted changes Basic Settings On the Basic Settings page you may set the 1oLogik E2260 s system time or provide the IP address of a time server for time synchronization iS f Basic Settings 0 Overview Time Settings HE Network Settings E A Time zone
2. pl E 000000000000000000000000 44 5 35 1 6 89 Ki Ye 2 Ke Le 1 J 79 1 6 ioLogik E2260 User s Manual Introduction Without LCD Module Unit mm 9 95 24 44 LO O 000000 19 46 51 op S i 9 5 O 121 8 24 VDC power input accept 12 to 48 VDC TBI 2 wire RS 485 interface Ax f Power Ready Serial LEDs FEEL Optional for LOM 2297088 a 280806 tr r N A IM 77 RS 485 baudrate dial HHHH OURO OUP URE ORE AAA AA EEN RJ45 Ethemet i ere PER POHD ar me u MOXA System Bus TO module latch E LO Status LEDs Release button for Removable terminal block for I O point cascaded L O module 3 81 mm max 14 AWG NOTE The reset button restarts the server and resets all settings to factory defaults Use a pointed object such as a straightened paper clip to hold the reset button down for 15 sec The RDY LED will turn red as you are holding the reset button down The factory defaults will be loaded once the RDY LED turns green again You may then release the reset button ioLogik E2260 User s Manual Introduction LED Indicators Ethernet Valid 10 Mbps Ethernet connection Ethernet Valid 100 Mbps Ethernet connection flashing Transmitting or receiving data System pred Paeria on SSS Powers off 2 ped Systemerror S Power is off or there is a power problem flashing Serial port is receiving transmitting data RTD R
3. 24 hour GMT Greenwich Mean Time Dublin Edinburgh Lisbon London v H 1 0 Settings EO Local time 2007 09 29 22 52 26 Modify L Lem System Elapsed Time 1 4 49 1 Change Password Time server Load Factory Default Web console Enable O Disable O Save Restart 4 2 ioLogik E2260 User s Manual Using the Web Console Network Settings General Settings On the General Settings page you may assign a server name and location to assist you in differentiating between different I O servers You may also enable the Host Communication Watchdog and define the timeout value m Overview 3 Basic Settings I O Server Settings 3 Network Settings Server Name E2260_Test2 General Settings Ethernet Configurations Server Location Location2 CO RS 485 Settings DNS Server 1 255 255 255 255 I O Settings DNS Server 2 255 255 255 255 System Management F Enable LCM communication 0 Change Password watchdog Load Factory Default Save Restart When enabled the Host Connection Watchdog activates Safe Status settings for DO channels when the ioLogik E2260 loses its network connection for the specified amount of time By default the Watchdog is disabled You may use ioAdmin to configure each DO channel s Safe Status setting To enable the Watchdog make sure that Enable connection watchdog is checked set the timeout value and restart the server
4. DOOO Mode rtd01 Type rtd08 Type red08 Type rtd08 Value rtd09 Value rtd10 Value rid11 Value DO02 PulseStart md04 Type DO02 Status rtd04 UnitType 3 3 3 DO02 Type_ id04 Valwe DO03 HighWidth td05 Emble DO03 Index rtdOS Index DO03 LowWidth td0S Type 3 3 3 3 3 DO03 Mode mdOS UmifIype o 3 3 DO03 PulseStart mdOS Valwe DO03 Status rtdO6 Imdex AAA DO03 Type rtd06 Type E Factory Default Settings Default IP Address Default Netmask Default Gateway Communication Watchdog RTD Mode Unit DO Mode DO Safe Status Power On Status Low Width for Pulse Hi Width for Pulse Output Pulses Password Module Name Module Location SNMP Community Contact Location Click amp Go The 10Logik E2260 is configured with the following factory defaults 192 168 127 254 255 255 255 0 0 0 0 0 Disable PT 100 Degree C DO Off Off 1 x 5 ms 1 x 5 ms 0 continuous NONE NONE NONE Enable Public NONE NONE NONE F Pinouts and Cable Wiring Ethernet Port Pinouts Serial Port Pinouts E2260 RS 485 Network Adapter Pin Assignment V V FG D D 56 RTD Input Wiring Structure 3 wire RTD ioLogik E2260 User s Manual Pinouts and Cable Wiring 2 wire mozi a a z 2 Zee 221 0 g 7 1 1 1 2 3 7 7 d 4 E 5 2 3 wire Ur MERK ee MK else BAR 0 g 0 1 1 1 2 2 3 7 3 4 4 5 2 7 Digital Output Structure BY Isolated Lo
5. E2260_Test2 Y Time Server Server Location Location2 Y Y System Log Server Address 192 168 127 2 Port 4040 A Refresh 3 13 ioLogik E2260 User s Manual Utilities Network Tab The Network tab is where you configure IP settings Modbus TCP Alive Check Timeout settings DNS settings Serial settings SNMP settings and Web Access settings for the 10Logik E2260 Y 10 Configuration W Server Info E x Server Settings Se Network a Firmware Update L Watchdog Y Click amp Go Logic Message Monitor Number of Modbus TCP connection s 2 IP Settings Serial Settings IP Configuration Static z Unit ID 1 IP Address 192 168 127 210 92 168 127 210 Baud Rate 115200 Data Bits 8 Subnet Mask 255 255 255 0 Stop Bits 1 Parity None Gateway 0 0 0 0 i Timeout ms 2500 Z MAC 00 90 E8 0E E0 15 Modbus TCP Alive Check Timeout SNMP Settings Y Enable Modbus TCP idle connection Y Enable SNMP timeout interval le pubic 000 60 sec Write Community private Y Contact DNS Settings a DNS 1 255 255 255 255 255 255 255 255 ENS 2 Web Access Settings Enable C Refresh IP Settings You can assign a static or dynamic IP address to the ioLogik E2260 as well as the subnet mask and gateway address The Accessible IP screen can be used to control network access to the 1oLogik E2260 and attached sensors The ioLogik will reject all requests that do not originate from sour
6. the action to take place select OR to specify that any one of the conditions may be satisfied for the action to take place Instead of performing an action under specified I O conditions you may wish to set up a heartbeat status message or action that repeats at regular intervals as long as the I O server is operational In this case you can set up a Time Trigger rule as the first IF condition For example you can set a 3600 second interval so that a TCP status message is sent every hour THEN Actions Under the THEN column you may set up to 3 actions that will be performed if the conditions under the IF column are satisfied The 3 actions may be any combination of DO status setting SNMP Trap Active Message by TCP UDP or E mail For SNMP Han Active Message and E mail actions use the following memo icon to additional parameters Logic 0 Configuration Y Enable IF THEN HIV RTD 0 y v0 Deg C HY Do 0 y OFF y er feo sd bue rer bo RS ASS B Sp Deg C N y Check every fo sec 0 level trigger once AND v Active Message E Mail Relation between conditions Equivalent Logic Statement RTD O O Deg C check every 0 sec DO 0 OFF Jf OK X Cancel 5 5 ioLogik E2260 User s Manual Click amp Go Logic Active Message Select Active Message for active I O messaging over TCP or UDP Click the memo icon to configure the message and parameters Note that TCP and UDP cann
7. the display will show the response time lt 1oLogik E2260 gt ping Enter this submenu to display the restart now submenu Enter the restart now submenu to display the restart option Press the center button to modify this option then select enable to save changes and reboot the I O server The disable option has no effect lt s1obogikK E2260 gt save restart WARNING Any configuration changes that are made through the LCM will not take effect until the 10Logik E2260 is restarted A 2 B Modbus TCP Address Mappings Oxxxx Read Write Coils Functions 1 5 15 00001 0x0000 l bit CHO RTD Reset Minimum Value lt R gt Always 0 lt W gt 1 Reset to current value O return illegal data value lt RW gt 0 Disable 1 Enable 00031 0x001E 1 bit CHO DO Status lt RW gt 0 OFF 1 ON ioLogik E2260 User s Manual Modbus TCP Address Mappings 00035 0x0022 1 bit CHO DO Power On Status lt RW gt 0 OFF 1 ON 00036 0x0023 CH1 DO Power On Status 00037 0x0024 CH2 DO Power On Status 0038 0x0025 lbit CH3 DO Power On Status 00039 0x0026 1 bit CHO DO Safe Status lt RW gt 0 OFF 1 ON 0040 0x0027 lbit CH1 DO Safe Status 0041 0x0028 1bit CH2 DO Safe Status 0042 0x0029 lbit CH3 DO Safe Status 00043 0x002A 1 bit CHO DO Pulse Output Status lt RW gt 0 Stop 1 Start 0044 0x002B JIbit CH1 DO Pulse Output Status 0045 0x002C JIbit ICH DO Pulse Output Status 0046 0x002D CH3 DO Pulse Output Status 00047 0x00
8. 120 Configuration r Fi Era EI Server Settings E Network o a Firmware Update Z Watchdog Y Click amp Go Logic Message Monitor 8 g m o Y Toggle HEX Messages may also be entered in HEX by selecting the Send as HEX checkbox When sending a message in HEX each HEX value must be delimited by commas Certain control characters will only appear in the Message Monitor when Toggle HEX is selected as in the following example E Message Content Settings Qu Message Content 01 02 05 31 32 49 50 51 52 GP Y Send as HEX seperated by 33 max chars 200 y 1 0 Configuration W Server Info E Server Settings E Network Message Receiver list global Messaging protocol global 9 EEE 9 EES y Click amp Go Logic Message Monitor 1 Dest IP 1192 168 127 2 c UDP UDP TCP 3 Dest IP 10 0 0 0 4 Dest IP 0 0 0 0 Message Port TCP UDP 5 pest IP 0 0 0 0 9000 Copy B Clear a 6 Dest IP 0 0 0 0 EE EE EE ee En 00 Y 120 Configuration W Server L EF Server Settings E Network Des IP kata a Firmware Update Watchdog Y Click amp Go Logic Message Monitor 8 Dest IP 0 0 0 0 UDP TCP S a o Dest IP 0 0 0 0 EN N 0203313249505152 Dest IP 0 0 0 0 V Toggle HEX 5 6 ioLogik E2260 User s Manual Click amp Go Logic SNMP Trap Select SNMP trap along with a trap number between 1 and 20 You may need to cons
9. Channels gt DO Channels LJ System Management Accessible IP Settings SNMP Agent Network Connection Firmware Update Import System Config VV VV V Y Export System Config LCM Change Password Load Factory Default Save Restart U U U U ioLogik E2260 User s Manual Using the Web Console Introduction to the Web Console The ioLogik E2260 web console is a browser based configuration utility When the ioLogik E2260 is connected to your network you may enter the server s IP address in your web browser to access the web console Note that although most configuration options are available in the web console some settings are only available through ioAdmin Furthermore the web console can be disabled under Web Access Settings in ioAdmin If you are unable to access the web console check the Web Access Settings in ioAdmin Total Solution for Industrial Device Networking SJ Main Menu 2260 HO Overview Basic Settings HC Network Settings 2 1 O Settings Welcome to ioLogik Series Active Ethernet I O Server Main Model Name E2260 95557 Window u Serial Number 10013 san AO System Management Firmware Version v1 0 Buildo7gaaefa E LCM Ethernet IP Address 192 40 227 254 L Ethernet MAC Address f0 90 e8 00 60 07 a Change eo RS 485 Setting 115200 n 8 1 Naviaati 1 Load Factory Default ER avigation BEBEB EB EB EB BE BE BE BE EE EE EE EE ENE EE EE EE BE BE EB EB EB EB EB BB Ee SE SG OO Save Restart Panel
10. Ethernet Configuration On the Ethernet Configuration page you may set up a static or dynamic IP address for the ioLogik E2260 as well as the subnet mask and gateway address mn Ethernet Configurations Basic Settings 2 3 Network Settings D General Settings Ethernet Parameters IP Configuration Static v IP Address 192 168 127 254 3 RS 485 Settings Subnet Mask 255 255 255 0 I O Settings Gateway 0 0 0 0 System Management LCM Change Password Load Factory Default Save Restart ioLogik E2260 User s Manual Using the Web Console RS 485 Settings On the RS 485 Settings page you may view the serial communication parameters but no configuration changes are allowed The baudrate may only be configured by the physical dial on the back of the ioLogik E2260 This is a reserved function RS 485 Settings Og Overview Basic Settings HEY Network Settings OO General Settings Serial Parameters Unit ID 0x01 Baud Rate 115200 OO Ethernet Configurations Data Bits 8 Stop Bits 1 1 0 Settings System Management J LCM Change Password Load Factory Default Save Restart ioLogik E2260 User s Manual Using the Web Console VO Settings RTD Channels On the RTD Channels page you may view the status of channels RTD 00 through RTD 11 which includes both physical and virtual channels i RTD Channel Settings 1 Overview S Basic Settings Channel Sensor Type Range
11. I O servers Click amp Go Moxa developed the Click amp Go Logic control interface for easy configuration and deployment of Active Ethernet I O Click amp Go s intuitive graphical interface lets administrators use simple IF THEN statements as rules to determine how the Active Ethernet I O server responds to different I O conditions For example the Active Ethernet I O server could be programmed so that if the temperature recorded by an attached sensor reaches a certain value an attached switch is turned on and an e mail is sent to an administrator Click amp Go makes it easy to define a set of these rules which will become the basis for your Active Ethernet I O system 1 2 ioLogik E2260 User s Manual Introduction Optional Liquid Crystal Display Module LCM In order to make user easy view the ioLogik E2260 supports an optional hot pluggable Liquid Crystal Display Module LCM for field management and configuration The LCM can display network and I O settings such as temperature value The ioLogik E2260 s IP address and netmask may also be configured using the LCM and one LCM can be used to maintain and configure all 10Logik 2000 devices Product Features e Click amp Go Logic for easy configuration of your Active Ethernet I O system e High speed active I O messaging e 6 input channels for 2 wire or 3 wire resistance temperature devices RTD such as PT100 JPT100 and more with software selectable filtering time e 4 ch
12. Server Setinos LAD Generale een 3 9 MESS E R e ee 3 9 10Admin Administrator FUNCTIONS sss sese 3 10 VO Configuration Tab Administrator iese esse esse ee ee ee 3 10 Server Settings Tab Administrator 3 13 Nero ab EN ES RA a ee 3 14 Firmware Update TB GR Ee Ee ee ee ee EE 3 15 Wal 0002 o O A EE GE 3 16 Chick Go Loric La ee Ge N Ge Ge A M 3 17 Chapter 4 Chapter 5 Appendix A Appendix B Server Context Mei ses ee ee ande dl de 3 18 Using TFTP to Import Export Contursi 3 20 Usine JOE vent 08 os RS aa 3 21 Installine iOB nee Bene 3 21 Basic UAC MOMS eier eine 3 21 CODTI SOUL I Oele 3 22 Checking Connected Devices 3 23 Opa Los Files eeu A A a EE N ee 3 23 Clear n ak he Bor Pe mt 3 23 Using the Web Eonsoleaan anna 4 1 Introduction tothe Web Consoles ED SE EE id 4 2 IS A 4 2 Network Sennas A dosent oun aan E suena ee ee 4 3 General SEINES io O ee 4 3 Ethernet Onis Ural Oi iaa A 3 RS AS oe ok M AE EA ta EE t 4 4 POSO AA AA IE A 5 RED Chacarita Ie De N A 5 BOESEM N N OR OE EN A 6 SV Stemi Mina sere SEER GEES Re EE RS EES ceca Di EG SG EG Ge GE GROETE ie ee Re GOS EG 4 7 Accessible IP Serine RE e alae ash end an esas ene cos een seen ee Ee Ee toes 4 7 SIN EP AG ds A 8 Network e T N sapa a N a a 4 8 Firmware Update to 4 8 Import System CONE Ge Ge GR Ge Ge A 9 EXPO System COMMS ia A 9 BEN osa EE ER OR EA OR LE N A 9 Change Password unseres 4 10 Load Factory Dallas ee sera 4 10 Save Re state ee ad 4 10 CliEk
13. Settings and Safe Status Settings are also available Configuring RTD Input Channels The 10Logik E2260 provides 6 fixed physical RTD input Resistance Temperature Detector channels each supporting up to 18 different types including PT50 PT100 JPT100 and more The RTD channels are numbered from channel 0 to channel 5 Channels 6 through 11 are virtual temperature channels that report running averages or deviations of selected RTD channels E RTD Channel 0 QUE ERT Channel 6 2 Config e Enable RTD Channel Settings Sensor Type Sensor PT100 2 0 00385 Z 200 07 850 0 C Temperature Unit C C A C Virtual Channel Settings al al al el r r Temperature Unit e Que 28 Conta v Enable RTD Channel Settings Sensor Type Temperature Unit Virtual Channel Settings Average Y RTD 00 ATD 03 C Deviation f RTD 02 RTD 05 F Temperature Unit 3 10 ioLogik E2260 Users Manual Utilities The following table is a list of supported sensor types and ranges 50 to 31000 1120 0 00672 Ni120 0 00672 _ 80 to 260 C 112 to 500 F 800 to 2600 The status of attached sensors will be reported by the count value which corresponds to the sensor ranges shown above For example for a 100 mQ resistor a count value of 10 corresponds to a 1 Q reading Moxa can only guarantee accuracy within the ranges shown above Be sure to verify the sensor ty
14. amp GS EOGIG nn 5 1 OV CT VN WV osc E E ER N RE 5 2 TE ee ee ee ee 5 2 Click amp Go LOGIC BASICS anne Ee aina aa A 5 3 KST Wii Rules years 5 3 DE LOSIE Rules ee a Eee 5 4 Summary ol LET HEN Parameter ee 5 4 TEC EG EA ME AE OE aan 5 5 THEN Achons ee ea esse 5 5 Working with Click amp Go Rylesels see ebenen 5 9 IA a a a a a 5 9 Ruleset Management e 5 9 Raal ESSEE TAA POH ES DOLL ne le 5 9 Liquid Crystal Display Module LCM esse ees Re RR RR RE ER RR ERGE ERK RR EE EER A 1 Modbus TCP Address Mappings iese ee EE RR EE EER RE EER RR EE ER RR EE EER Rae ERK Rae EE B 1 Oxxxx Read Write Coils Functions 1 5 151 B 1 3xxxx Read Only REE O iia B 2 4xxxx Read Write Registers Functions 3 6 16 cocccccncccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnos B 3 SXXX Write Registers LUCIO ED een B 6 Appendix C Appendix D Appendix E Appendix F Appendix G Used Network Port Numbetrs enenenenenanananananannananenenenananana na C 2 SNMP MIB Diaria D 1 RFC1213 MIB II Supported SNMP Variables esse sees ee eea D 1 Factory Default Settings nnonnnnennnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnana E 2 Pinouts and Cable Wiring iss De t F 2 EthemetPort re dde F 2 Seal POR P Nous A ee OT EG Me ee F 2 REEDE WEES os Se Ge F 2 SN F 2 ZN ENE EE EE N EE N ER EE F 3 INT ee atv natu AR EE EE OE F 3 8 ui ES LE RE ia F 3 SS HEIA e PEE E P ee eee ee E nen F 3 SUD of la F 4 Te
15. server is to attach the appropriate 10Logik R2000 I O server The two servers can be snapped together using the RS 485 system bus connector as shown in the following figure Digital I O channels can be added using the ioLogik R2110 and analog I O channels can be added using the 1oLogik E2140 For additional details please refer to the ioLogik R2110 or R2140 user s manual 2 See y male TE Te Ee fin e e ea WENNER EIE EE EN bi om in bi mes ie mm m ha min mae vel add a HE ar nbn 59 _ EEEE eee ee ee N 6 EE TEN Le EET EE a a RT m mm m un ales lma ll eom m EE a z E s Software Installation 10Admin is a Windows utility provided for the configuration and management of the ioLogik E2260 and attached I O devices It may be used from anywhere on the network to monitor and configure the 10Logik E2260 You may also configure some of the settings through the web console or optional LCM 1 Installation from CD Insert the Document and Software CD into the host computer In the root directory of the CD locate and run SETUP EXE The installation program will guide you through the installation process and install the 1o Admin utility You can also install the MXIO DLL library or ioEventLog separately 2 Open ioAdmin After installation is finished run ioAdmin from Start gt Program Files gt Moxa gt IO Server gt Utility gt ioAdmin 3 Search the network for the server On the menu bar select System gt Auto S
16. 0 DO62 6 D0 D063 8 D0 SensoF SensoF SensoF SensoF sensor sensor sensor sensor sensor sensor sensor sensor Type 1 PT 188 Enable 1 Type 1 PT 188 Enable 1 Type 14 Resistance Enable 1 Type 1 PT 188 Enable 1 Type 1 PT 188 Enable 1 Type 1 PT 188 Enable 1 Type 26 AUG Enable 1 Formula 6 Type 26 AUG Enable 1 Formula 6 Type 26 AUG Enable 1 Formula 6 Type 28 AUG Enable 1 Formula 6 Type 28 AUG Enable 1 Formula 6 Type 28 AUG Enable 1 Formula 6 DO66_PWN 6 OFF DOG6_SAFE 6 OFF DO61_PWN 6 OFF DO61_SAFE 6 OFF DO62_PWN 6 OFF DO62_SAFE 6 OFF DO63_PWN 6 OFF DO63_SAFE 6 OFF 3 Modbus address table CHANNEL RTD88 RTD61 RTD 62 RTD83 3 3 1 0 TYPE MODBUS REFERENCE MODBUS ADDRESS Dec Hex Input 36661 8x8088 Input 36662 0x0001 Input 36663 8x8882 Input 30004 0x0003 Select Server List File to Import EI Y Select All Select I 0 Server to Import X unSelect All v 2 22260 Test1 E2260 192 168 127 253 v 3 E2260 Test E2210 192 168 127 220 v 4R2110_Test R2110 192 168 127 254 2 X Cancel ioLogik E2260 User s Manual Utilities ioAdmin Main Screen Main Screen Overview This is ioAdmin s main screen The main window defaults to the I O Configuration tab which displays a figure of the 10Logik E2260 and the status of every I O channel below it The other tabs in t
17. 0 0 00618 600t0 2500 i200 0 00618 60 to 250 C 600 to 2500 i120 0 00672 80 to 260 C 800 to 2600 Channels 6 through 11 are virtual channels You can click on a virtual channel to configure whether it will return current averages or deviations for the specified physical channels RTD 00 through RTD 05 DO Channels On the DO Channels page you may configure each DO digital output channel by clicking on the channel DO Channels can operate in DO mode or Pulse Output mode In DO mode output is either on or off In Pulse Output mode a configurable square wave is generated Im DO Channel Settings LJ Overview oS Basic Settings DO Channel Status Low Width High Width Mi Network Settings DO 00 Off E I O Settings DO 01 Off 3 RTD Channels DO 02 Off DO 03 off 3 System Management S LCM 9 Change Password 9 Load Factory Default Save Restart NOTE channel is locked by logic http 192 168 127 254 DO Channel Settings Microso EJ DO Channel 0 Settings Mode DO Status Pulse Low Pulse High Pulse Count Pulse Start 1 Current Setting Pulse Output 214748 214748 214748 O 2 Power On Setting oft y o 4 Safe Status Setting orf v Note Pulse width unit 5ms range 1 65535 Warning Be sure to Save Restart your setting You may use the Power On Setting field to specify the channel s status when the ioLogik E2260
18. 2E 1 bit CHO DO Power On Pulse Output Status lt RW gt 0 Stop 1 Start 00048 0x002F CH1 DO Power On Pulse Output Status 00049 0x0030 CH2 DO Power On Pulse Output Status 00050 0x0031 CH3 DO Power On Pulse Output Status 00051 0x0032 1 bit CHO DO Safe Mode Pulse Output Status lt RW gt 0 Stop 1 Start 00052 0x0033 CH1 DO Safe Mode Pulse Output Status 00053 0x0034 CH2 DO Safe Mode Pulse Output Status 00054 0x0035 CH3 DO Safe Mode Pulse Output Status 3xxxx Read Only Registers Function 4 30001 0x0000 1 word CHO RTD Value lt R gt 0 65535 Unit 0 1 Ohm Celsius Fahrenheit CHI RTD Value Virtual CH6 RTD Value lt R gt 0 65535 Unit 0 1 Celsius Fahrenheit 30013 0x000C 1 word CHO RTD Minimum Value lt R gt 0 65535 Unit 0 1 Ohm Celsius Fahrenheit ioLogik E2260 User s Manual Modbus TCP Address Mappings lt R gt 0 65535 Unit 0 1 Ohm Celsius Fahrenheit 4xxxx Read Write Registers Functions 3 6 16 lt RW gt 0 4294967295 lt RW gt 0 4294967295 lt RW gt 0 4294967295 lt RW gt 0 4294967295 ioLogik E2260 User s Manual Modbus TCP Address Mappings lt RW gt 0 4294967295 lt RW gt 0 4294967295 40025 0x0018 1 word CHO DO Operation Mode lt RW gt 0 DO Mode 1 Pulse Output Mode 40026 0x0019 CH1 DO Operation Mode 40027 0x001A CH2 DO Operation Mode 40028 0x001B l word CH3 DO Operation Mode CHO RTD Engineering Unit 0 Ohm 1 Celsius 2 Fahrenheit CH4 RTD Engineering Unit 0x0021 1 w
19. Ethernet I 0 Server 6RTD 4DO MOD LOC MOD NAME 2 1 0 Configurations RTDGG 6 C Sensor Type 1 PT 166 Enable 1 RTD61 8 C Sensor Type 1 PT 188 Enable 1 RTD82 2 2 Sensor Type 14 Resistance Enable 1 RTDO3 6 C Sensor Type 1 PT 188 Enable 1 RTD64 8 C Sensor Type 1 PT 188 Enable 1 RTDO5 6 C Sensor Type 1 PT 188 Enable 1 RTDG6 6 C Sensor Type 26 AUG Enable 1 Formula 8 RTD87 8 C Sensor Type 26 AUG Enable 1 Formula 6 RTD68 8 C Sensor Type 26 AUG Enable 1 Formula 6 RTDO9 6 C Sensor Type 26 AUG Enable 1 Formula 6 RTD16 6 C Sensor Type 26 AUG Enable 1 Formula 6 RTD11 6 C Sensor Type 26 AUG Enable 1 Formula 8 D083 8 D0 D063 PUN OFF DOG3 SAFE 6 OFF DO66 6 D0 DOGG PWN OFF DO4A SAFE 6 OFF DO81 8 DO DO61_PWN 6 OFF DO61_SAFE 6 OFF D082 8 D0 D062 PWN 8 0ff DOK SAFE 8 0ff 3 Modbus address table CHANNEL 1 0 TYPE HODBUS REFERENCE MODBUS ADDRESS Dec Hex RTD66 Input 36661 9x6666 RTD61 Input 36662 9x6661 RTD 62 Input 36663 8x8882 RTD63 Input 30004 8x8883 Import System Config Select this command to reload a configuration that was exported to a text file You will need to log in as an administrator to use this function You will need to restart the ioLogik server in order for the new configuration to take effect This command may be used to restore a configuration after loa
20. I O Configuration tab Select Wiring Guide in the submenu to open a help file showing the wiring information and electrical characteristics of the ioLogik E2260 E2260 Active Ethernet VO with Ethernet 6 RTD input and 4 Digital output System Overview Ethernet pin assignment 0000900 LB HHH HH HHHH HHHH HHHH EER EER REE RE EE HH H Ve V FG Dr D SG Ethemet RS 485 Communication Settings 115200ps N81 57600bps N81 38400bps N81 19200bps N81 9600bps N81 4800bps N81 2400bps N81 1200bps N81 ioLogik x E2260 Active Ethernet I O RTD 4 Digital ourpar NONANO JBEE0000000000000000000000 Wiring Example RTD Input 1 2 Wire RTD loLogik E2260 User s Manual Utilities Menu Items File system From the File menu you can export the list of I O servers that are currently displayed in the navigation panel You also can import a list of I O servers into ioAdmin MOXA ioAdmin File System Sort Help ES s w Import 1 0 Server List Export 1 0 Server List Exit E2260 lt 192 168 127 253 gt y 1 0 Configuration Ser 9 6 Location an E2260 lt 192 168 127 254 gt mm Sosssossssssssensssssssnssssssuuensssssssnssssssssssssssssssesee Til DIAN 7109 1C0 177 DRA N When importing a server list you will be prompted to select which servers on the list need to be imported Select I 0 Server to Import Select Server List File to Import D Server
21. List sit Y SelectAll 3 unSelect All viil E2260 Test2 E 2260 192 168 127 254 v 2 E2260_Testl E2260 192 168 127 253 v 3 E2260_Test E2210 192 168 127 220 v 4R2110 Test R2110 192 168 127 254 2 X Cancel The file will have a SLT extension and can be opened as a text file The server list will provide the following information for each server 1 Server Name 2 Module Type 3 IP Address 4 Unit ID Several operations are possible from the System menu Auto Scan Active Ethernet I O Server will search for 10Logik servers on the network When connecting for the first time or recovering from a network disconnection you can use this command to find I O servers that are on the network Network Interface allows you to select a network to use if the PC has multiple network adapters installed I O Status Refresh Rate is used to adjust how often the I O server is polled for device status The current rate is displayed on the status bar at the bottom of the window Note that higher sync rates result in higher loads on the network 3 6 ioLogik E2260 Users Manual Utilities Sort Help TCP Socket Timeout Interval allows you to select the preferred timeout value for TCP socket communication COM Port Setting is used to set the parameters for Modbus communciation such as baudrate data bits and timeout interval For most applications this will involve connecting to 10Logik R Series devices Active Me
22. O mode the specification is as follows Type Logic 0 OFF Logic 1 ON In Pulse Output mode the selected digital output channel will generate a square wave as specified in the pulse mode parameters The low and high level widths are entered in multiples of 5 ms with a maximum setting of 4 294 967 295 or 248 days 13 hours 13 minutes and 56 seconds To set the low level width for 500 ms you would enter 100 because 100 x 5 ms 500 ms If the low width value is 500 and the high width value is 500 the pulse output would be a square wave with a 5 second pulse cycle If continuous pulse output is desired enter 0 for the number of pulses otherwise enter the desired number of pulses between 1 and 4 294 967 295 Power On Settings Use this field to set the initial behavior of the DO channel when the ioLogik E2260 is powered on You may configure whether or not the DO is set to OFF or ON at power up For DO channels in Output Pulse mode you may configure whether or not the pulse output commences at power up Safe Status Settings Use this field to specify how the DO channel behaves when the network connection is lost When the network connection is lost for the amount of time specified in the Host Connection Watchdog each output channel will be reset to its Safe Status settings Note that the Host Connection Watchdog is disabled by default If the Host Connection Watchdog is disabled the Safe Status settings will have no effect You
23. Status Value ae RTD 00 PT 100 200 850T Enabled N I O Settings L RTD 01 Disabled RTD 02 Disabled 3 DO Channels RTD 03 Disabled RTD 04 Disabled RTD 05 Disabled Virtual Channel RTD 06 3 Load Factory Default RTD 07 HE System Management A LCM 9 Change Password 3 Save Restart RTD 08 RTD 09 RTD 10 RTD 11 NOTE channel is locked by logic Clear Max amp Min You may click on each channel to enable or disable it or to configure the RTD input mode When a channel has been disabled the sample rate of the remaining channels will be increased automatically St IgA IRR 127 254 TO Channel Setting Y 7http 7192 168 127 254 RTD Channel Setting E ATO Channe pl 0 Settings ETO Channel 6 Settings Enable Range Un Mode Selected Channel init E F E OL ATO 04 E i ATO 02 avd a Cl eT 1 1 Di ato oa P A eto a 1 Di aro 05 Warning Be sure to Save Restart pour setting Subin lana Warning Be sure lo Save Ridan your selling The following table is a list of supported sensor types and ranges 501031000 Res 20 m0 1 to 620 Q 50 to 31000 Res 10 mQ 1 to 310 Q 100 to 31000 4 5 ioLogik E2260 User s Manual Using the Web Console Sensor Type N 60 to 250 C 600 to 2500 N Ni500 0 00618 60 to 250 C 600 to 2500 N11000 0 00618 60 to 180 C 600 to 1800 N i10
24. TD x 6 pins Channel off Digital Output AN ou Do This chapter describes how to install the 1oLogik E2260 The following topics are covered LJ Hardware Installation gt VV Y gt Connecting the Power Grounding the ioLogik E2260 Connecting to the Network Setting the RS 485 Baudrate Adding More I O Channels O Software Installation 2 Initial Setup ioLogik E2260 User s Manual Initial Setup Hardware Installation Connecting the Power Connect the 12 to 48 VDC power line to the ioLogik E2260 s terminal block TB1 If power is properly supplied the Power LED will glow a solid red color until the system is ready ATTENTION Disconnect the power before installing and wiring Disconnect the power cord before installing and or wiring your ioLogik E2260 Do not exceed the maximum current for the wiring Determine the maximum possible current for each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current exceeds the maximum rating the wiring could overheat causing serious damage to your equipment Grounding the ioLogik E2260 There are two grounding points on the ioLogik E2260 the wall mounting point and the DIN rail mounting plate Note that both grounding points are actually connected to the same conducting pathway Connecting to the Network 1 Connect the ioLogik E2260 to the host PC with an Ethernet cable For initial
25. V WV Using TFTP to Import Export Configuration Using ioEventLog ioLogik E2260 Users Manual Utilities Introduction to ioAdmin The 1oLogik I O server may be managed and configured over the Ethernet by ioAdmin a Windows utility provided with your 1oLogik E2260 ioAdmin s graphical user interface gives you easy access to all status information and settings The ioLogik E2260 also supports configuration by web console and by optional LCM but full configuration and management is only available through ioAdmin A new feature in ioAdmin automatically detects IP conflicts between ioLogik E2000 units If 10Admin detects an IP conflict a window will appear that allows you to resolve the IP conflict immediately and restart each unit 10Admin also includes Click amp Go Logic control for the configuration of your Active Ethernet I O system 10Admin consists of following software e ioAdmin with Click amp Go Logic e ioLogik 2000 Wiring Guide e ioLogik 4000 Wiring Guide Features of ioAdmin Remote Management AAR AE Over the Ethernet network ioAdmin Sia E allows users to El E OK ada ia e find and configure multiple 10Logik servers DE HAMA Pr ATA e monitor and configure attached I O vg EE N EN E met m mm TT m L m a devices p s V li a a a iili en a a test I O devices ma u ur y a ur i a at ar Del reset the server ele EE On line Wiring Guide An on line wiring guid
26. annels for 24 VDC output with Pulse Output mode and software selectable pulse width e 10 100 Mbps Ethernet supporting Modbus TCP and up to 10 hosts e Windows utility and quick programming library for VB VC BCB coming soon e Expandable I O through optional RS 485 modules e Supports SCADA software including Wonderware InTouch and GE Intellution 1F1x32 e SNMP for system management and I O status e Remote management over the network including firmware updates e Supports TFTP server to import configuration e Power on and safe status settings for digital output e Optional hot pluggable LCM for status display and configuration Packing List The 1oLogik E2260 is shipped with the following items Standard Accessories e ioLogik E2260 Active Ethernet VO server e Document and Software CD Optional Accessories e LDP1602 10Logik liquid crystal display module LCM NOTE Notify your sales representative if any of the above items are missing or damaged ioLogik E2260 User s Manual Introduction Product Specifications LAN Ethernet Protection Protocols Serial Interface Serial Line Protection 10 100 Mbps RJ45 1 5 KV magnetic isolation Modbus TCP TCP IP UDP DHCP Bootp SNMP MIB for I O and Network HTTP RS 485 2 wire Datat Data GND 15 KV ESD for all signals Serial Communication Parameters Parity Data Bits Stop Bits Flow Control Speed Protocol Built in RTC RTD Input Channels VO Mode I
27. assist you in the management of your devices eee Network Connection Basic Settings 1 Network Settings HC 1 0 Settings 7 3 System Management Total connection s 1 Host Address Connection Type 192 168 127 3 Web HTTP Accessible IP Settings SNMP Agent Firmware Update Import System Config Export System Config E LCM 4 Change Password fa Load Factory Default OD Save Restart Firmware Update On the Firmware Update page you may load new or updated firmware onto the 1oLogik i Firmware Update LJ Overview Basic Settings JO Network Settings A VO Settings 3 System Management Choose a new firmware file path eee Accessible IP Settings Warning 1 The firmware update process may take about few minutes SNMP Agent 2 Attention Once you press the Update button this progress cannot be reversed Network Connection 3 Disconnecting power or network cable would lead to firmware corruption during the time Import System Config m Export System Config LCM Y Change Password 3 Load Factory Default 3 Save Restart 4 8 ioLogik E2260 User s Manual Using the Web Console Import System Config On the Import System Config page you may import a configuration onto the 1oLogik server The configuration file must have been generated by ioAdmin or through the web console This function can be used to duplicate settings between 10Logik servers You w
28. can Active Ethernet I O Server In the dialog window that appears click Start Search to begin searching for the ioLogik E2260 ANOVA Todi 2 Mm F ml Hea WE ELITE S Se laat Module Connection tin De ET Auto Searching for ioLogik 1 0 Server s Ked auto teach bara E Ehana 10 serser P FS RES UU server Tha d 166 cover mrt 5 i Tael onderdeel LA era sess Freed Zeh inr ethernet soin Ep Pete 2 3 ioLogik E2260 User s Manual Initial Setup If ioAdmin is unable to find the ioLogik E2260 there may be a problem with your network settings When multiple ioLogik E2000 units are on the same network remember that each unit has the same default IP address You will need to assign a different IP address to each unit to avoid IP conflicts ioAdmin automatically detects IP conflicts and gives you a chance to modify each unit s IP address in the IP Address columns Click the Set button to reboot the corresponding unit with its new IP address Click the Re Search button to refresh the list of units found by ioAdmin TP A ess Conflic WARNING IP address conflict detected modify them to different address before proceeding 140 Server MAC Address Description E2240 192168127254 Set O0 90 E8 0E E9 F1 Active Ethemet O Server BAI 240 E2210 192 168 127 254 00 90 E8 0E E0 15 Active Ethernet 1 0 Server 12D1 8D0 E2210 192 168 127 254 00 90 E8 DE E0 2C Active E
29. can configure whether or not the DO is set to OFF or ON for Safe Status For DO channels in Output Pulse mode you can configure whether or not the output pulse commences or continues for Safe Status 3 12 ioLogik E2260 User s Manual Utilities Test DO You may test the DO channel by using ioAdmin fF DO Channel 0 Jog Contig Test DO Mode Pulse Output Mode Status DO DO set the DO to ON or OFF DO Pulse activate or stop pulse generation server Settings Tab Administrator You may set up a password server name location date time zone and time server in the Server Settings tab ioAdmin supports long server names and a location description up to 58 chars If you will be using ioEventLog to receive server status reports such as for warm or cold starts indicate the IP address and port number for the PC that will be running ioEventLog in the System Log field The default port number is 4040 For additional information please refer the 1oEventLog section later in this chapter o Configuration Server Info Server Settings LS Network amp Firmware Update L Watchdog Y Click amp Go Logic Message Monitor Password for entry 1 Logout Management Settings Time Settings Change Password 8 char max Local Date 2007 3 2 39 5 28 Reconfirm Password Time 4 E 124 S AE Y Update Time Zone Server Name GMT Greenwich Mean Time Dut y
30. ces listed in the accessible IP list Leave this list blank in order to allow requests from any IP address Modbus TCP Alive Check Timeout The Modbus TCP Alive Check Timeout is designed to avoid TCP connection failure When the host is down the ioLogik E2260 will continue to wait for a response from the host This will cause the TCP port to be indefinitely occupied by the host When the Modbus TCP idle connection timeout interval is enabled the ioLogik E2260 will close the TCP connection automatically if there is no TCP activity for the specified time Please note that Modbus TCP connections will be blocked when setting up Accessible IP DNS Settings Use this field to specify up the IP addresses of up to 2 DNS servers These two DNS servers may be used to automatically find available e mail addresses when using Click amp Go Logic Serial Settings You may view the reserved RS 485 communication parameters here and you may set the timeout value for breaks in RS 485 communication Note that the other serial communication parameters cannot be modified If you wish to adjust the baudrate you will need to use the physical dial on the back panel of the 1oLogik E2260 SNMP Settings The ioLogik E2260 supports SNMP v2 Simple Network Management Protocol to allow monitoring of network and I O devices with SNMP Network Management software It is useful in building automation and telecom applications Use these fields to enable SNMP and set the read and w
31. cy to within 0 1 C while another product may achieve accuracy to within 0 5 C Simple Verification at Your Site Product specifications may be verified by using a qualified RTD sensor The sensor can be placed into 0 C or 100 C water to see if the temperature readings are correct A high precision resistor may also be used for measurement Verification with RTD Sensor When using an RTD sensor measurement errors are introduced through the sensor itself and through the analog to digital signal processing For example suppose that the RTD sensor introduces 0 05 error and the AD conversion introduces 0 1 error For water at a 100 C the measured temperature would fall somewhere within 100 1050 0 1 0 05 or between 98 425 C and 101 575 C The 1050 corresponds to the full range of the PT100 RTD sensor which is 200 C to 850 C Therefore with an RTD sensor that boasts accuracy within 0 05 the measured temperature will be accurate to within 0 15 of FSR Verification with Precision Resistor A resistor with Ohm input could be used for verification Suppose that you use the ioLogik E2260 which is rated at 100 Q 1 and select 1 310 Q mode The measured temperature would fall within 100 100 x 1 310 Q x 0 1 or between 98 69 Q and 101 31 Q The 310 corresponds to the full scale range of 1 310 Q mode
32. ding the factory defaults or to duplicate a configuration to multiple ioLogik servers 3 19 ioLogik E2260 Users Manual Utilities Using TFTP to Import Export Configuration A TFTP Trivial File Transfer Protocol provides basic FTP functionality in a very simple protocol Due to TFTP s simplicity it can be implemented using a very small amount of memory an important consideration when it was first developed The ioLogik E2260 supports the use of TFTP to import or export configuration files The following is an example using Windows TFTP and an 1oLogik E2260 with an IP address of 192 168 127 254 1 Enter TFTP 192 168 127 254 GET 1k2260 txt to get the ioLogik s configuration file 2 Enter TFTP 192 168 127 254 PUT 1k2260 txt to load a configuration file onto the 10Logik You must use 1k2260 txt as the destination filename when copying a configuration file to the 10Logik E2260 Otherwise you will receive an error message as shown below Error on server ocma i srv 58 tcp PCMail Server snmp 31 udp SNMP snmpt rap 52 udp snmp trap SNMP trap print srv 707 HIPX over IP L jghtweight Directory A MCom MCc 443 udp MCo You can use TFTP in a batch file to transfer configuration files for different units For example you might have two configuration files that need to be copied to two different servers 1k2260_1 txt for 192 168 127 253 and 1k2260 2 txt for 192 168 127 254 A batch file could be
33. dmin onto the ioLogik E2260 e Run The Run command starts Active Ethernet I O operation using the ruleset that the 10Logik E2260 booted up with e Stop The Stop command stops Active Ethernet I O operation Ruleset Import Export Although rulesets alone cannot be imported and exported the entire system configuration including the current ruleset may be imported and exported As you make changes to a ruleset you may export the system configuration in order to save that ruleset 5 9 A Liquid Crystal Display Module LCM The 1oLogik E2260 supports an optional detachable Liquid Crystal Display Module LCM for easier field maintenance The LCM is hot pluggable and can be used to configure the network settings or display other settings When plugged in the LCM displays the ioLogik E2260 home page and pressing any button takes you into the settings and configuration LCM Controls The up and down buttons navigate between the current options The right and left buttons enter and exit the submenus The center button is used when modifying settings or restarting the server go to the previous item go to the next item exit the current submenu and return to the previous menu go up one level Right enter the selected submenu go down one level enter exit editing mode An e in the upper right hand corner of the display indicates that the parameter can be modified Press the center button on the LCM to modify that param
34. dule Attached sa I O Settings Firmware Version 1 0 0 0 System Management Firmware Release Date 03 01 2006 Change Password 4 9 ioLogik E2260 User s Manual Using the Web Console Change Password Change Password m Overview 9 Basic Settings H Network Settings a E Old password HI 1 0 Settings Password HEY System Management New password Accessible IP Settings Retype password SNMP Agent 3 Network Connection 9 Firmware Update Import System Config 9 Export System Config 3 Load Factory Default Save Restart When changing the ioLogik E2260 s password settings you will first need to enter the old password Leave this blank if you are setting up password protection for the first time To set up a new password or change the existing password enter your desired password under both New password and Confirm password To remove password protection leave the New password and Confirm password fields blank ATTENTION If you forget the password the ONLY way to configure the ioLogik E2260 is by using the reset button to load the factory defaults Before you set a password for the first time it is a good idea to complete the 1oLogik s configuration and export the configuration to a file The configuration can then be easily loaded imported back into the ioLogik E2260 if it has been reset to factory defaults Load Factory Default This function will reset all of the ioLogik E2260 s s
35. e Windows PC You will need to set up your ioLogik server to send status events to the PC s IP address The following events are monitored e cold start e warm start For each event the following information is provided The log can be sorted by any of these fields e Event type e Event date and time e ioLogik server source name e Source IP e Destination IP e Host date and time e Source model 3 21 ioLogik E2260 User s Manual Utilities System Connection n EE WEA Event type Event Date Time Source Name Source IP Destination IP Host Date Time Source Model ee LE A A AAA AAA AAA A AAA AAA 0 00 02 35 10 16 51 Active Client Connections 1 Configuration In the System menu select Settings to configure ioEventLog Alarm Listen For Pott 4040 Log Director Directory C Program Files dora obrar Ll tility slog Screen Cola Event Type Color Cold Start Mer Warn Start cca lt l Off Line More l On Line McGreen gt The Alarm Listen Port is the TCP port number that will be monitored for status events You can modify this setting as necessary to receive signals through a firewall It will need to match the settings for the ioLogik server that is being monitored The Log Directory is where the log files will be stored The default directory is C Program Files Moxa ioMIrror log A separate log file is created for each day with file names assigned automatically You can als
36. e can be opened from within 1oAdmin for your convenience The easily accessible wiring guide can save administrators much time while planning or troubleshooting Ethernet pin assignment RS 485 Communication 3 2 ioLogik E2260 User s Manual Utilities Configuration File 10Admin allows the entire configuration of the 1oLogik E2260 to be saved as a file The file is viewable as text and can serve three purposes e asa record or backup of configuration e asa template for the configuration of other servers e asaguick reference guide for you to configure Modbus drivers in a SCADA system The file includes the following information 1 file name date and time 2 model information 3 Modbus addresses Server Management List ioAdmin can import and export a list of ioLogik servers that are being managed This file can make it easier to manage all devices on the network and includes the following information 1 Server Name 2 Module Type 3 IP Address 4 Unit ID ioLogik E2266 Network 1 0 Server Configuration Date 2667 16 36 Time 16 33 38 Firmware V1 0 Build67163611 1 Model MOD_TYPE E2266 Active Ethernet I 0 Server 6RTD 4DO MOD LOC MOD NAME 2 1 0 Configurations RTD88 8 C RTD81 8 C RTD82 2 12 RTD83 8 C RTD84 8 C RTD85 8 C RTD86 8 C RTD87 8 C RTD88 8 C RTD89 8 C RTD18 8 C RTD11 8 C DO66 6 D0 D061 8 D
37. eter s settings LCM Options Display Explanation Actions lt ioLogik E2260 gt This is the default home page showing the IP address Press the down button to view the submenus Enter this submenu to display information about the specific server you are viewing serial number SLOLOGIK E2260 gt name server location e2260 f w ver lem f w ver model name ioLogik E2260 User s Manual Liquid Crystal Display Module LCM Display Explanation Actions Enter this submenu to display information and settings for the network e ethernet link MAC address lt ioLogik E2260 gt IP mode network IP address netmask gateway DNS server 1 DNS server 2 Enter this submenu to display information about the ruleset lt ioLogik E2260 gt being used by the active I O system click amp go e name status lt ioLogik E2260 gt Enter this submenu to display the RS 485 cascade port settings serial port Enter this submenu to access I O channel status Here are examples of settings that you might see e RTD 00 XXX C lt ioLogik E2260 gt i o setting Press up or down to navigate through the different I O channels without having to go back to the previous menu lt loLogik E2260 gt Enter this submenu to see ifthe web console is enabled or console disabled Select this option to enter an IP address to ping If you get a timeout error it indicates that the E2260 cannot reach that IP address Otherwise
38. ettings to the factory default values All previous settings including the console password will be lost Save Restart If you change the configuration do not forget to reboot the system 4 10 D Click amp Go Logic Click amp Go Logic was developed by Moxa to provide an easy way to program your ioLogik E2260 for active I O messaging In the chapter we will show you how Click amp Go Logic works and how to use it to develop your active I O messaging program The following topics are covered in this chapter a a a Overview Features Click amp Go Logic Basics gt Working with Rules Defining Logic Rules gt Summary of IF THEN Parameters gt IF Conditions gt THEN Actions Working with Click amp Go Rulesets gt Activating the Ruleset gt Ruleset Management Bar gt Ruleset Import Export ioLogik E2260 User s Manual Click amp Go Logic Overview The ioLogik E2260 s Active Ethernet I O system eliminates the need for host computers to continually poll I O devices for status Instead the server itself 1s able to monitors the status of each I O device and take the appropriate action when the I O status satisfies a user defined condition For example the ioLogik E2260 could be configured to send a TCP UDP message only when a temperature sensor attached to RTD 0 reports a reading of 85 C This structure results in a much improved response time and a much reduced load on the host computer s CPU and on network bandw
39. fo EP Server Settings Message Monitor Channel MON RTD 01 RTD 02 RTD 03 RTD 04 RTD 05 RTD 06 RTD 07 RTD 08 RTD RTD 10 RTD 11 Server Info Tab Server information such as firmware revision is displayed in the Server Info tab y 1 0 Configuration W Server Info E Server Settings Message Monitor Unit ID for MODBUS RTU 34100 Moxa Technologies Inc Vendor Name Product Name EMM EMO Seve A AAA Firmware Version Firmware Release Date Emm ea BEDR S o O Number of TCP connection 0x0100 Ethemet Interface S peed 10 100 MAC Address 34107 00 90 E8 00 60 07 LCM Detection ams vis LCM Firmware Revision Read 34110 Build06030112 03 01 2006 LCM Firmware Release Date E ystem Elapsed Time in sec 44097 192 168 127 254 Read Wtite IP Address 44098 255 255 255 0 Head mie Subnet Mask 44099 0 0 0 0 Read Write Gateway 44100 Read Write Modbus TCP Alive Check Timeout 44101 0003 0040 0004 0028 0009 2007 Read Write 23 E vstem Local Time 44102 Read Write 44104 255 255 255 255 Read Write System Time Zone DNS1 Server Address 44105 255 255 255 255 Read Write Read Write DNS2 Server Address Enable Disable Web Access Read Write 3 8 Timeout for Communication Watchdog ioLogik E2260 Use
40. g 192 168 1 0 and 255 255 255 0 e To allow unrestricted access Deselect the Enable the accessible IP list option Refer to the following table for additional configuration examples Allowed Hosts IP address Netmask Anyhost Disable 192 168 1 120 192 168 1 120 255 255 255 255 192 168 1 1 to 192 168 1 254 192 168 1 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 1 1 to 192 168 1 126 192 168 1 0 255 255 255 128 192 168 1 129 to 192 168 1 254 192 168 1 128 255 255 255 128 4 7 ioLogik E2260 User s Manual Using the Web Console SNMP Agent On the SNMP Agent page you may enable SNMP and set the read and write community strings The 10Logik E2260 supports SNMP v2 Simple Network Management Protocol to allow monitoring of network and I O devices with SNMP Network Management software It is useful in building automation and telecom applications Agen LJ Overview OG Basic Settings H Network Settings VO Settings 3 System Management ur Accessible IP Settings Write Community Name public Contact Configurations SNMP Enable Disable Read Community Name public Network Connection Location Firmware Update Import System Config Export System Config 5 LCM J Change Password Load Factory Default 3 Save Restart Network Connection On the Network Connection page you may view the TCP connections from other hosts This may
41. he main window take you to server and network settings and further functions are available when you log on as an administrator Note that configuration options are not available until you log on as an administrator mA GOA LE E E E E E E 2 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E Tri E ATOR PT100 HIDE m Fro IATOE 02 esistance TOE 03 PT ion TOP 04 Prion E E ATOR 05 Prion ATO 06 TAN ATOR OF AM E ATO OH CAND ATOE 09 LANG R 11 tava E pa 11 JAM E E E na f EE LO eee pase i y Haaie Main window syne rate status Status bar mi iN ud nm ULI 0 0 3 4 bie id BRR EEE TEETE Ed da dk EMM EN e RT MOHN P HE ad Ad 200 050 D 200 0 450 0 10 2100 AM AREA D MAER 0 2001 08501 D eg Deg E Ohm Dag E Dep C Deo E Deu C Beg E Dep C Ben E Dew E Beg E Aidan dd asada TTT Dat 00 bo on Dar mm HU el Par oF Do on may 03 Pp DRI ee 40 4 9 32 EEEE EE Der EE loLogik E2260 User s Manual Utilities Wiring Guide 10Admin provides a wiring guide to the ioLogik E2260 You may access the wiring guide by right clicking the figure of the 10Logik E2260 in the
42. idth Click amp Go Logic was developed to provide an easy and intuitive way to configure when and how I O information is transmitted over the network Using simple If Then statements you set the conditions that need to be satisfied and the resulting actions Up to three conditions and three actions can be combined in any one rule and up to 16 rules can be defined in a ruleset Each SNMP trap or TCP UDP message can be transmitted to up to 10 computers simultaneously Features Click amp Go Logic s key features are as follows e Easy local logic control with intuitive If Then construction e Up to 16 user defined rules e Up to 3 VO based conditions and 3 DO or network actions per rule e Email TCP UDP or SNMP trap for active I O messaging e Customizable message content with dynamic fields for time date IP address and more e Up to 10 simultaneous IP destinations for TCP UDP messaging e Configurable interval for time triggered events 9 2 ioLogik E2260 User s Manual Click amp Go Logic Click amp Go Logic Basics To use Click amp Go Logic open ioAdmin and log on as an administrator on the Server Settings tab Once you are logged on go to the Click amp Go Logic tab It should appear as follows Q 140 Configuration Server Info F Server Settings Sy Network E Firmware Update Y Watchdog Y Click amp Go Logic Message Monitor EET Click amp Go Logic Tab 1 Logic Name In this field you may ass
43. ign a name for the set of rules 2 Rules List In this area each rule s conditions actions and status are displayed 3 Ruleset Management Bar In this area you manage the ruleset Working with Rules Rules are the building blocks of your Active Ethernet I O system With rules you define the exact trigger conditions for transmission of I O information as well as the content and destination of that information DO operation can also be automated based on RTD trigger conditions In the main screen you will see the list of rules in the current ruleset Double click on a rule to open that rule s configuration window or double click on an empty rule to start a new rule 5 3 ioLogik E2260 User s Manual Click amp Go Logic Tie Spim al Help del 4 id E mas 1421641273 miil raal Te D ae gt 10 Configuration W Serve into GP Server Settings Ma Hetero E rege odo Z watchdog kitol Merzoge Monitor vo Logic 0 Configuration RTDI 0 0 Dag Ge cehesk every U apel AX reeg The configuration window is where the rule is defined Basic If Then logic is used to set up temperature event based triggers The Equivalent Logic Statement at the bottom shows a real time text based summary of the rule that you are defining It can be a useful way to make sure that the rule is designed as you intended ATTENTION The unit of measurement is defined on the I O configuration tab When an I O chan
44. il address in the From Address field Under Mail Server Settings you must configure the IP address of the SMTP server with your username and password Since the 10Logik E2260 supports DNS you may enter the domain name of the SMTP server EMail Settings Jo Mail Content Settings Mail Subject This is an example of sending email Mail Content This is an example of sending email 7 Keyword Lookup 36 max chars 200 Mail Address Settings global Name Mail Address amp Available receiverls list Receiverfs list Name e Mail Address Name e Mail Address xl ITS Support moxa com From Address Mail Server Settings global SMTP Server Address IP Login Name Login Password X Cancel 5 8 ioLogik E2260 User s Manual Click amp Go Logic Working with Click amp Go Rulesets Activating the Ruleset A Click amp Go Logic ruleset contains up to 16 rules that act as the brain of your Active Ethernet I O system The Click amp Go Logic tab lists the rules in the current ruleset which work together to determine what I O information is sent who it is sent to how it is sent and under what I O conditions it is sent This simple but powerful tool is significantly more efficient with network and CPU resources than traditional blanket polling methods By default the ioLogik E2260 operates as a passive remote server In order to operate as an Active Ethernet I O server you must defi
45. ill be prompted for the location of the configuration file 1 e 1k2260 txt Import System Configuration File fa Overview Ga Basic Settings Ba Network Settings E I O Settings He System Management am Accessible IP Settings Warning 9 SNMP Agent Choose a system configuration file path 1 The file import process may take around 10 seconds 2 Disconnecting power or network cable would lead to system configuration file corruption during the time Ga Network Connection a Firmware Update Export System Config LCM fa Change Password Ga Load Factory Default Y Save Restart Export System Config On the Export System Config page you may save the ioLogik s configuration into a file for backup or import into another ioLogik server Gao E Export System Settings pr verview Ga Basic Settings Network Settings E 1 0 Settings oe System Management fa Accessible IP Settings 2 SNMP Agent fa Network Connection fa Firmware Update Click ik2260 txt to export amp save system settings fa Import System Config I Change Password 1 Load Factory Default GO Save Restart LCM If you have installed the optional LCM you may view the LCM s status and firmware details on the LCM page Total Solution for Industrial Device Networking E Main Menu E2210 ea Overview E Basic Settings LCM Module Information d LCM Module EE l La sengs LCM Mo
46. in Administrator Functions For full access to all configuration options log in as an administrator in the Server Settings tab This is required whenever you start up ioAdmin or boot up restart the ioLogik E2260 When you install the 10Logik E2260 for the first time the password will be blank and you may simply click Login Additional functions will available after logging in including the following new tabs Be Network Firmware Update s Watchdog Click amp Go Logic When making configuration changes you will need to click Update or Apply to save the changes Some changes will require a restart of the 1oLogik E2260 in order to take effect and you will be given the option to restart the computer if necessary ATTENTION You MUST log in to access any administrator function including Network Communication Watchdog Timer and Firmware Update tabs If you forget the password you may hold down the 10Logik s reset button to clear the password and load factory defaults This will result in the loss of all configuration settings and your Click amp Go Logic ruleset A VO Configuration Tab Administrator When logged on as an administrator you may double click on a channel in the I O Configuration tab to configure that channel s settings A window will open with configuration options for that channel Settings made in this window can be copied to all I O channels using the Apply to all channels option Options for Power On
47. ioLogik E2260 User s Manual First Edition November 2007 www moxa com product ioLogik E2260 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2007 Moxa Technologies Co Ltd All rights reserved Reproduction without permission is prohibited Trademarks Moxa is a registered trademark of the Moxa Group All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This manual might include unintentional technical or typographical errors Changes are made periodically to the information herein to correct such errors and these changes are incorporated into new editions of the manual Chapter 1 Chapte
48. is powered on and the Safe Status Setting field to specify the channel s status if the network is disconnected Note that Safe Status is controlled by the Host Connection Watchdog which is disabled by default If the Host Connection Watchdog is disabled the channels Safe Status settings will have no effect 4 6 ioLogik E2260 User s Manual Using the Web Console System Management Accessible IP Settings On the Accessible IP Settings page you may control network access to the 1oLogik E2260 When the accessible IP list 1s enabled a host s IP address must be listed in order to have access to the 10Logik E2260 Accessible IP Settings 7 Overview Y Basic Settings O Enable the accessible IP list Disable will not allow all IP s connection request Network Settings No Active IP Address Netmask HO VO Settings 1 33 System Management SNMP Agent 9 Network Connection Firmware Update 3 Import System Config 9 Export System Config LCM Change Password Load Factory Default 9 Save Restart KBC ME Ak NE MEME m o You may add a specific address or range of addresses by using a combination of IP address and netmask as follows To allow access to a specific IP address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and netmask use 0 for the last digit e
49. ne a ruleset and then perform the following three steps 1 The ruleset must be downloaded from ioAdmin onto the ioLogik E2260 You may do so by clicking on Download in the Ruleset Management bar 2 After the ruleset has been downloaded the ioLogik E2260 must be restarted You may do this by right clicking on the server name in the navigation panel in ioAdmin and selecting Restart Do not use the reset button as that will load all factory defaults and erase your ruleset from memory 3 After the ioLogik E2260 has restarted the ruleset must be activated for Active Ethernet I O operation First you will need to log in as an administrator again in ioAdmin s Server Setting tab Once you have logged in go to the Click amp Go Logic tab and click Run in the Ruleset Management bar This will activate the ruleset and the 1oLogik E2260 will begin Active Ethernet I O operation When the ruleset has been activated it will remain active even when the 10Logik E2260 is disconnected from the host computer or from the network If the ioLogik E2260 is turned off Active Ethernet I O operation will resume when it is turned back on This allows you to use the 10Logik E2260 for PC independent automation Ruleset Management Bar e Clear The Clear command erases the ruleset in both ioAdmin and in the 1oLogik E2260 e Retrieve The Retrieve command copies the ruleset from the ioLogik E2260 into ioAdmin e Download The Download command copies the ruleset from 1oA
50. nel is being used in a Click amp Go Logic rule the channel s range and units may not be modified Defining Logic Rules Each rule consists of two columns The IF column defines I O conditions and the THEN column defines actions When the ioLogik server detects that the IF conditions have been satisfied the THEN actions will be performed Summary of IF THEN Parameters IF Conditions Max value 4 294 967 295 Time Trigger Max value 4 294 967 295 for Condition 1 only N A time interval 5 4 ioLogik E2260 User s Manual Click amp Go Logic IF Conditions Under the IF column you may set up to 3 IF conditions As soon as the IF conditions are satisfied the THEN actions are performed For example an alarm can be activated when a temperature exceeds a certain level Use the pull downs to specify the conditions and units of measurement e g RTD 0 gt 60 C The available operators are lt gt lt and gt You may want an action to be repeated for as long as the conditions remain satisfied For example instead of simply turning on an alarm you may wish to send an alert message every five minutes for as long as the temperature exceeds a certain level You can set a repeating interval in the Check every ___ sec field The THEN action will be repeated at the specified interval for as long as the set of IF conditions 1s satisfied Under Relation between condition select AND to specify that all conditions must satisfied for
51. not be updated over Ethernet 3 15 ioLogik E2260 Users Manual Utilities Watchdog Tab The Watchdog tab is where you configure the Host Connection Watchdog which is used with the Safe Status settings to define each DO channel s response to a lost network connection When the Host Connection Watchdog is enabled the 10Logik E2260 will respond to network disconnections that exceed the specified amount of time The 1oLogik will respond by resetting DO channels to their Safe Status settings By default the Watchdog is disabled To enable the Watchdog make sure Enable Host Connection Watchdog is checked set the Timeout value then click the Update button Y 1 0 Configuration ul Server Info 5 Server Settings En Network F Firmware Update L Watchdog 8 3 Click amp Go Logic Message Monitor Hast Connection Monitor Enable Host Connection Watchdog m a Timeout value sec Lv mae Ifthe Watchdog s enabled and the network connection has been lost you will need to return to the Watchdog Tab in order to resume normal operation There will be a message saying Host Connection Lost indicating that Safe Status settings have been activated Click Clear Alarm to exit Safe Status and return to normal operation D Configuration ib Server Info 17 Server Settings SL Network AS Firmware Update Watchdog w Click amp Go Logic Message Monitor Host Connection Monitor le Enable Host Connecti
52. nput Impedance Input Connection Resolution Sample Rate Accuracy Zero Drift Span Drift CMR 50 60Hz NMR 50 60Hz Optical Isolation Supported RTD Types None 8 1 None 1200 to 115200 bps Modbus RTU Yes 6 resistance temperature devices PT JPT Ni resistor with burn out detection 5 MQ typical 625 KQ min 2 or 3 wire 16 bits 12 samples sec all channels 0 1 3 uV C typical 25 ppm C 120 dB 100 dB 2 KVrms 3 KVDC Sensor Type Degree Degree Res 100 mQ 1 to 2200 Q 1to 2200 Q Res 50 mQ 1 to 1250 1to 1250 Q Res 20 mQ 1 to 620 Q 1 to 620 2 Res 10 mQ 1 to 310 Q 1 to 310 Q PT50 0 00385 PT100 0 00385 PT200 0 00385 200 to 850 C 328 to 1562 F 200 to 850 C 328 to 1562 F 200 to 850 C 328 to 1562 F PT500 0 00385 200 to 850 C 328 to 1562 F PT1000 0 00385 200 to 350 C 328 to 662 F JPT100 0 003916 200 to 640 C 328 to 1184 F JPT200 0 003916 200 to 640 C 328 to 1184 F JPT500 0 003916 200 to 640 C 328 to 1184 F JPT1000 0 003916 200 to 350 C 328 to 662 F N1100 0 00618 60 to 250 C 76 to 482 F N1200 0 00618 60 to 250 C 76 to 482 F N1500 0 00618 60 to 250 C 76 to 482 F Ni1000 0 00618 60 to 180 C 76 to 356 F Ni120 0 00672 80 to 260 C 112 to 500 F Count 10 to 22000 20 to 25000 50 to 31000 100 to 31000 2000 to 8500 2000 to 8500 2000 to 8500 2000 to 8500 2000 to 3500 2000 to 6400 2000 to 6400 2000 to 6400 2000 t
53. o 3500 600 to 2500 600 to 2500 600 to 2500 600 to 1800 800 to 2600 ioLogik E2260 User s Manual Introduction Virtual RTD Channels Operation Mode Digital Output Channels On state Voltage Output Current Rating Optical Isolation Protection Power Requirements Power Input Power Consumption Field Power Mechanical Specifications Wiring Environmental Operating Temperature Storage Temperature Shock Freefall Vibration MTBF Agency Approvals EMC Safety Warranty Period 6 Average Subtraction 4 sink type 24 VDC nominal 30 VDC max Max 200 mA per channel 2 KVrms 3 KVDC Over temperature shutdown 170 C Over current limit 750 mA channel typical 24 VDC nominal 12 to 48 VDC max 2 16 W 24 VDC typical 3 54 W with LCM max 24 VDC nominal up to 48 VDC VO cable max 14 AWG 10 to 60 C 14 to 140 F 5 to 95 RH 40 to 85 C 4 to 185 F 5 to 95 RH IEC60068 2 27 IEC60068 2 32 IEC60068 2 6 gt 200 000 hrs 25 C FCC Part 15 CISPR EN55022 Class A CE IEC61000 4 2 ESD Level 2 3 CE IEC61000 4 3 RS Level 2 CE IEC61000 4 4 EFT Level 2 CE IEC61000 4 5 Surge Level 3 CE IEC61000 4 6 CS Level 2 CE IEC61000 4 8 PM Level 1 CE IEC61000 4 11 Dip CE EN61000 6 2 CE EN61000 6 4 UL 508 2 years 1 5 Introduction ioLogik E2260 User s Manual Physical Dimensions With LCD Module 45 63 5 95 l Unit mm 000000 9 51
54. o Default la Export System Config j Import System Config Id lt Connect Select this command to have ioAdmin attempt a re connection over the network to the selected 10Logik server Disconnect Select this command to have ioAdmin drop the network connection with the selected ioLogik server Delete VO Server Select this command to have 1o Admin remove the selected server Add Serial VO Server Select this command to manually add a serial I O server by using its Unit ID Restart System Select this command to restart the selected ioLogik server You will need to log in as an administrator to use this function Reset to Default Select this command to reset all settings for the selected ioLogik server including console password and IP address to factory default values You will need to log in as an administrator to use this function Export System Config Select this command to export the configuration of the selected ioLogik server to a text file You will need to log in as an administrator to use this function It is strongly recommended you use this method to back up your configuration after you have finished configuring the ioLogik for your application The following is an example of the exported configuration file 3 18 ioLogik E2260 Users Manual Utilities ioLogik E2266 Network 1 0 Server Configuration Date 2007 10 30 Time 16 33 38 Firmware Ui Build67163611 1 Model MOD TYPE E2268 Active
55. o select the color of each event type in the log 3 22 loLogik E2260 User s Manual Utilities Checking Connected Devices You can see which I O servers are already connected to ioEventLog by selecting Connected Device List from the Connection menu You will be prompted to view which devices are connected amp Connected Device List Coe Refresh Opening Log Files You can view previously saved logs by selecting Open from the Log menu You will be prompted for the data that you wish to view lt Date of Log File E E E Select date of lag file to view Sun Mon Tue Wed Thu Fri 1 oe 2 E 7 TE 7 am 11 13 14 15 16 17 18 0 21 22 3 4d 25 ef 28 29 30 Jl lt 3 Today 5 10 2007 x Cancel The logs for the day that you select will be displayed in the Alarm Log Viewer window Clearing the Log If you wish to clear the log you can select Clear from Log menu This will clear all events for the current day The cleared events will not be saved in that day s logs After the logs are cleared new events will be displayed and recorded as usual 3 23 ioLogik E2260 Users Manual Utilities 3 24 4 Using the Web Console You may use the ioLogik E2260 s built in web console to configure many options The following topics are covered L Introduction to the Web Console LI Basic Settings OU Network Settings gt General Settings gt Ethernet Configuration gt RS 485 Settings LU VO Settings gt RTD
56. on Watchdog Timeout value 5 SEC Host Connection Lost Alarmed y Clear Alarm 3 16 ioLogik E2260 Users Manual Utilities Click amp Go Logic Tab The Click amp Go Logic tab is where Active Ethernet I O operation is configured While traditional Ethernet I O involves an I O server that reacts passively to polling requests from a network host Active Ethernet I O involves an I O server that actively reports I O data under user specified conditions Click amp Go Logic is a powerful and easy to use tool to define the conditions for reporting I O data Please refer to Chapter 5 for more information Y 120 Configuration Fi Server Info EN Server Settings E Network a Firmware Update L Watchdog Y Click amp Go Logic Message Monitor Logic Name 0 H 2 3 H4 5 H6 7 8 de Changes made in the Click amp Go Logic tab are not effective until the 10Logik E2260 is restarted just like changes made in other tabs Note that when an I O channel is used in Click amp Go Logic its range and units become fixed and cannot be modified ioLogik E2260 Users Manual Utilities Server Context Menu The Server context menu is accessed by right clicking on the server model name in the navigation panel E MOXA ioAdmin File System Sort Help a a g Host 169 254 10 109 192 168 GR ioLogik dB 192 168 127 210 E2210 AB 192 168 Disconnect ntr Add Serial 1 0 Server u Restart System Reset t
57. ord Virtual CH6 RTD Engineering Unit 1 Celsius 2 Fahrenheit 0x0024 word 40041 0x0028 1 word CHO RTD Sensor Type O PT50 1 PT100 2 PT200 3 PT500 4 PT1000 5 JPT100 6 JPT200 7 JPT500 8 JPT1000 9 N1100 10 NI200 11 NI500 12 NI1000 13 NI120 14 310 Ohm 15 620 Ohm 16 1250 Ohm 17 2500 Ohm 40042 0x0029 1word CHI RTD Sensor Type B 4 ioLogik E2260 User s Manual Modbus TCP Address Mappings 40047 0x002E 1 word CH6 RTD Sensor Type 20 AVG 21 DIV word 1 word word word word 40053 0x0034 1 word CHO RTD Reset Minimum Value lt R gt Always 0 lt W gt 1 Reset 0 return illegal data value word word word word 1 word word word word word word word 40065 0x0040 1 word CHO RTD Reset Maximum Value lt R gt Always 0 lt W gt 1 Reset O return illegal data value word word word word word word word lt RW gt 0 OFF 1 ON lt RW gt 0 OFF 1 ON B 5 ioLogik E2260 User s Manual Modbus TCP Address Mappings lt RW gt 0 OFF 1 ON CHO DO Pulse Output Status lt RW gt 0 Stop 1 Start CHO DO Power On Pulse Output Status lt RW gt 0 Stop 1 Start 4 0 l 0101 0095 x005E CH2 DO Pulse Output Status 40096 0x005F l word CH3 DO Pulse Output Status 40097 0x0060 1 word CHO DO Safe Pulse Output Status lt RW gt 0 Stop 1 Start 40098 0x0061 CH1 DO Pulse Output Status 40099 0x0062 CH2 DO Pulse Output Status 40100 x0063 J1word CH3 DO Pulse Output Sta
58. ot be used at the same time within a ruleset all rules must use the same protocol After clicking the memo icon you may enter your desired message in the Message Content window Dynamic fields such as time date IP address and I O status may be inserted in your message by clicking on the Keyword Lookup button Up to 10 IP destinations for the message can be specified in the Message Receiver list The default Message Port is 9000 and this can be modified as necessary to work with your firewall By default messages are sent in ASCII although ioAdmin can display the message in HEX in Message Monitor E Message Content Settings Joe Message Content This is ASCII format wheih made at lt TIME gt Dest IP 0 0 0 0 UDP rcp Dest IP 0 0 0 0 i KAKA 5343494920666F726D61742077686369682060616465206174203032343338343132 Dest IP 0 0 0 0 Dest IP 0 0 0 0 BR Cony Copy Keyword Lookup U 41 max chars 200 Y 10 Configuration W Server Info Ey Server Settings Se Network Send as HEX seperated by amp Fimware Update Watchdog Y Click amp GoLogic Message Monitor Message Receiver list global Messaging protocol global UDP TCP oo pa e UDP This is ASCII format whcih made at 02 34 23 2 Dest IP 0 0 0 0 C TCP 3 Dest IP 0 0 0 0 4 Dest IP 0 0 0 0 Message Port TCP UDP Copy i 7 Toggle HEX 5 Dest IP 0 0 0 0 9000 N ee er 6 Dest IP 0 0 0 0 y
59. passive in the sense that I O servers wait passively to be polled by a host computer The response time in this type of setup however tends to be on the order of seconds The passive remote I O structure is simply inadequate for data acquisition and control systems that require a response time on the order of hundredths of seconds Active Ethernet VO Moxa s Active Ethernet I O line was developed specifically to address the limitations of the traditional passive approach Rather than having the host computer poll the I O device server over the network for the status of each I O device the Active Ethernet I O server intelligently sends the host computer status information under user specified conditions This is a report by exception approach which greatly reduces the load on CPU and network resources Network packets are far fewer in number and far smaller in size since I O information is only sent when necessary and only information from the specified I O device is sent Based on field tests of an 10Logik E2000 series server used in an RFID system 50 ms is the typical response time over a 100 Mbps Ethernet network Moxa s active I O messaging system uses TCP or UDP for I O messaging and supports sending messages to up to ten host computers simultaneously In addition to providing intelligent status reporting Active Ethernet I O servers are backwards compatible with all of the functions and capabilities of traditional passive remote
60. pe Accurate readings beyond these ranges cannot be guaranteed Virtual Channels The ioLogik E2260 provides virtual channels so you can easily determine the average or deviation values for any attached temperature sensor A virtual channel can operate in Average Mode or Deviation Mode In Average Mode up to 6 physical channels are selected and the virtual channel reports the average value of the selected channels In Deviation mode two physical channels are selected and the virtual channel reports the difference between the channels When using virtual channels if there are errors on any of the selected physical channels that channel s readings will simply be ignored You can refer to the LED indicators to see if any errors are encountered with any of the physical channels Note that virtual channels only support temperature units and cannot be used with resistance units Any channel that is connected to a resistance sensor will be treated as an error channel ioLogik E2260 Users Manual Utilities Configuring Digital Output Channels The 1oLogik E2260 is equipped with 4 digital output channels that can be set individually to DO or Pulse Output mode DO Channel 0 Qu 2 Config Test 1 Mode Settings Mode ro y Pulse mode ad 2 Power On Settings DO status Pulse mode parameter OFF M je 3 Safe Status Settings DO status Pulse mode parameter OFF M ja Apply to all channels LY In D
61. r 2 Chapter 3 Table of Contents INTOAUCHIO EE ER ER EE 1 1 A EE A ANE E ee Re oe ens E ens eee 1 2 Traditional Remote Unas 1 2 A Re De ek GE oi Go Re oe ee ie ed 1 2 CH KE AE N EE ER EE NE ee 1 2 Optional Liquid Crystal Display Module LCM 1 3 Product E EALES dida 1 3 Packs E E ES GE ae ee Oe ae ee ee ee 1 3 Product specihica on aie ss ee ee ne ee 1 4 Physical Dies on ae ee ee ee ee est 1 6 With CD Modules steile 1 6 Without LED Module suas 1 7 Hardware Reference ee EE EE ir ee le ee 1 7 Piel Gelde od oe gs nom ols oe be ED ah ee aaa oa ER 1 7 LE Ed IE ap O ee een 1 8 TET a SetuP need de n ER NG De Ge EER ED 2 1 Hardware Installation bo ee GR 2 2 COMME CUNO the Powerline 2 2 Grounding tie 10 LOGIE E2200 nennen 2 2 Connecting 10 Me NELWOIK aan Een 2 2 Settino the RS 485 BAUATALS EE nu Eisen 2 2 Addie More VO Chase ee ee ee 2 3 Sottwate Installalon oe ee agas 2 3 A Ee EE Ee N r hk ee ee ita De Pe De a 3 1 Introduction OO UI EE a E O ee GE 3 2 Er ALU SOE L A E case occ e De iii S 3 2 OA dit Mali SEIEEN A ER EG EE EE EG a EE DO EG EE Ge 3 4 Maim Steel OVS VIEW ne rs Ne ee pa i ORR Ne nea ee 3 4 MP eee rer 3 5 INAS UE LOTS ien see ie De een 3 6 O oe EO OT E AE EE 3 6 cA ER a nr ace a RE ela hoe 3 6 SOLD ahaa ee haa a ee aial oh oad al ED ai aata 3 7 212 Ed OK ees EE EE HI ED RE EG EEN 3 7 A ed ER RE es OO N A 3 7 Mi NV AO A e ds 3 8 VO Configuration Tab General ne ee ee 3 8 A T n EEE E E IE aes anno et Ee E GE EE tes 3 8
62. rite community strings Web Access Settings This field enables and disables the 10Logik E2260 s web console The web console allows the configuration of many settings using a web browser that is directed to the server s IP address If the web console is not enabled in this field you will not be able to access the web console ioLogik E2260 Users Manual Utilities Firmware Update Tab The 10Logik E2260 supports remote firmware updates through the Firmware Update tab Enter the path to the firmware file or click on the icon to browse for the file Click Update to update the firmware The wizard will lead you through the process until the server is restarted y 140 Configuration Server Info Server Settings Ski Network 2 Firmware Update Watchdog Y Click amp Go Logic Message Monitor Firmware File Path RER EEE Warning 1 The firmware download may take around 2 minutes 2 Disconnecting power or network cable during the time would lead to firmware corruption Step 2 2 Total progress WARNING Do not interrupt the firmware update process An interruption in the process may result in your device becoming unrecoverable After the firmware is updated the 10oLogik will restart and you will have to log in again to access administrator functions The firmware on any attached I O expansion module such as an ioLogik R2000 server must be updated over the RS 485 bus Firmware on cascaded modules can
63. rminal Block PAASSTOTIMAENMES arena F 4 see ds AE EE OE EE N EE RE EE N G 1 621 Ni ACLU SS ee ee Bere as G 1 Simple Verification af OUP SHE ld ee G 1 Werificationm with RID SAS cool G 1 Verification with Precision Resistor G 1 1 Introduction The 10Logik E2260 is a stand alone Active Ethernet I O server It connects RTD sensors and digital output on off switches for automation applications over Ethernet and IP based networks The following topics are covered in this chapter Q Overview gt Traditional Remote I O gt Active Ethernet I O gt Click amp Go gt Optional Liquid Crystal Display Module LCM Product Features Packing List Product Specifications DDUL Physical Dimensions gt With LCD Module gt Without LCD Module 0 Hardware Reference gt Panel Guide gt LED Indicators ioLogik E2260 User s Manual Introduction Overview TL ne shown with and without optional LCM The 10Logik E2260 is part of the E2000 line of 1oLogik Active Ethernet I O servers which are designed for intelligent pro active status reporting of attached sensors transmitters transducers and valves over a network It includes 2 MB of Flash ROM and 8 MB of SDRAM An optional hot pluggable Liquid Crystal Display Module LCM can be used to view and configure device settings Traditional Remote VO Ethernet remote I O solutions have been on the market for a long time Traditional solutions are
64. rs Manual Utilities server Settings Tab General The Server Settings tab is where you log in as an administrator This is required in order to gain access to the ioLogik E2260 configuration options If no administrator password has been set up simply click Login and leave the Password for entry field blank Please refer to the io Admin Administrator Functions section later on in this chapter for more detail 10 Configuration Server Info 4 Server Settings Message Monitor Password for entry amp Login F Management Settings Time Settings a por ss ie 2 e ds a M Update E2250 Tes2 i SA KATE pa fLocation2 pete Y Update System Log di Message Monitor Tab The Message Monitor tab will display any TCP UDP VO messages received from the 1oLogik E2260 When you install the 1oLogik E2260 for the first time the Click amp Go ruleset will not have been defined yet so no messages will be displayed Please refer to Chapter 5 for information on using Click amp Go Once a ruleset has been ddefined and activated any TCP UDP messages sent from the ioLogik E2260 will be displayed in the Message Monitor tab 1 0 Configuration Server Info Server Settings gt Message Monitor UDP rep EX Copy D Clear FF Toggle HEX Messages can be displayed in ASCII or in HEX To display messages in HEX make sure that Toggle HEX is checked 3 9 ioLogik E2260 Users Manual Utilities ioAdm
65. setup of the 10Logik E2260 it is recommended that the ioLogik E2260 be configured using a direct connection to a host computer rather than remotely over the network 2 Note the ioLogik s default IP settings IP Address 192 168 127 254 255 255 255 0 Configure the host PC s IP address to 192 168 127 xxx xxx from 001 to 253 so the ioLogik will be visible on the network In Windows you will need to do this through the Control Panel 3 UseioAdmin or the web console to detect the ioLogik E2260 Once the ioLogik E2260 has been detected modify the settings as needed for your network environment then restart the ioLogik E2260 For information on ioAdmin please refer to Software Installation later in this chapter setting the RS 485 Baudrate The RS 485 port on the ioLogik E2260 is reserved for connecting to another RS 485 I O server The RS 485 port can run Modbus RTU or I O command sets The baudrate is set by a physical dial on the back of the 1oLogik E2260 The default settings are baudrate 115200 parity check N data bits 8 and stop bit 1 Baudrate for RS 485 Dial setting and corresponding baudrate parameters are N 8 1 0 115200 1 57600 2 38400 3 19200 4 9600 5 4800 6 2400 7 1200 Remember to restart the ioLogik E2260 after making any changes to the RS 485 baudrate ioLogik E2260 User s Manual Initial Setup Adding More VO Channels A cost effective way to add more I O channels to your ioLogik E2000 I O
66. ssage Listen Port specifies the port number to use for Active Ethernet I O messages If your network uses a firewall you can coordinate this setting with your firewall settings to ensure that active messages get through Reset NA4010 Network Adapter IP is used to re assign an IP address to the NA 4010 network adapter for ioLogik 4000 systems MOXA ioAdmin File System Sort Help a g w gt 8 Hu Auto Scan Active Ethernet 1 0 Server i Network Interface I O Status Refresh Rate TCP Socket T meout Interval m COM Port Setting Act ve Message Listen Port Reset NA4010 Network Adapter IP Enable Host Lonne or The Sort menu allows the server list in the navigation panel to be sorted by connection type and location Sort Help Fe a v Sl By 1 0 Server Connection By 1 0 Server Type W By 1 0 Server Location In the Help menu you can view wiring guides and information about ioAdmin Help 52 E Wiring Guide for iologik2000 Wiring Guide for 1oLogik4000 About Quick Links Quick links are provided to search for I O servers on the network and sort the server list ns y AA Search network for I O servers Sort by connection Sort by I O server type E Sort by location 3 7 ioLogik E2260 Users Manual Utilities Main Window VO Configuration Tab General The I O Configuration tab shows the status of every I O channel This is the default tab when you first open ioAdmin 120 Configuration l Server In
67. thernet 170 Server 12D1 8D0 X lanore these devices 4 Monitoring VO status Once the ioLogik E2260 is found by 1oAdmin you may view the status of all I O devices on ioAdmin s main screen MOXA rohdmi ak Fie Gym Sgt Hep rif mr lt Bl Hos 0000 ia vd raad z E 142160137 253 SE w MD Configuration id Serem inta Server Sira gt Message Monds EETL GRASSE GAD AA Ad dd titt AR kk hd dd FERM EE EE WEAR ma hate Moan toLog a ttf E E 1 AI MIERE ETE Ff N EEE Needy z C Tasa Rere H T 000020 Fl 012505 You may now use ioAdmin to set up or configure your ioLogik E2260 3 Utilities This chapter goes over the functions available in ioAdmin the ioLogik E2260 s main configuration and management utility The following topics are covered a a a U D O Introduction to ioAdmin Features of ioAdmin ioAdmin Main Screen gt Main Screen Overview gt Wiring Guide Menu Items gt File gt System gt Sort gt Help gt Quick Links Main Window gt I O Configuration Tab General gt Server Info Tab gt Server Settings Tab General gt Message Monitor Tab ioAdmin Administrator Functions gt I O Configuration Tab Administrator Server Settings Tab Administrator Network Tab Firmware Update Tab Watchdog Tab Click amp Go Logic Tab Server Context Menu VV V
68. tus 4 4 0 _ ee 1 word CHO RTD Enable lt RW gt 0 Disable 1 Enable 5xxxx Write Registers Function 8 Sub function Data Field Request Data Field Response 0x0001 OxFFOO Echo Request Data Reboot 0x0001 OXSSAA Echo Request Data Reset with Factory default C Used Network Port Numbers E2260 Network Port Usage 68 o UDP BOOTPC 68 jub DHCP 69 UDP _ Export Import File 80 TCP WebServer SNMP 9020 Peer to Peer Function D SNMP MIB II RFC1213 MIB II Supported SNMP Variables The following SNMP variables are built into the 10Logik firmware and are compliant with RFC1213 MIB II Interfaces MIB ifAdminStatus ifDescr if utNUcastPkts ifinUcasPkts iflnUnknownProtos ioLogik E2260 User s Manual SNMP Agents with MIB II ipAdEntAddr IpAdEntBeastAddr ipAdEntlfIndex ipAdEntNetMask 3 ipDefault TL ipForwarding ipForwDatagrams ipFragCreates ipFragFails ipFragOKs ipInAddrErrors ipInDelivers ipinDiseards lemplnRedirecis lempOutEmors ooo lemplnSreQuenchs lempOutMsss D 2 ioLogik E2260 User s Manual SNMP Agents with MIB II lepCommRemPort gt hepOumss o H snmpOutBadValues D 3 ioLogik E2260 User s Manual SNMP Agents with MIB II Private MIB File and SNMP Variables Moxa also provides an SNMP to I O MIB file that can help you monitor I O status with SNMP software You can find the MIB file on the Document and Software CD rtd07 Index rtd08 Index
69. ult with your network administrator to determine how trap numbers will be used and defined in your network Click the memo icon to specify up to 10 IP addresses to receive the SNMP trap You can also bind the status of up to three I O channels within each trap THEN 1 le SNMP trap y 2 v Messaging y 3 Ie E mail y E SNMP Trap Settings Quay Binding Variables Bind 120 channel status R Bind1 0 channel status s Bind1 0 channel status Manager List Global Setting Manager IP Manager IP Manager IP Manager IP Manager IP Manager IP Manager IP Manager IP 1 2 El 4 at 6 T 8 9 Manager IP om E Manager IP 5 7 ioLogik E2260 User s Manual Click amp Go Logic E mail Select E mail to send a user defined email to the specified addresses Click the memo icon to enter the desired message and the intended recipients Dynamic fields such as time date IP address and I O status may be inserted in your message by clicking on the Keyword Lookup button To select a recipient you must first add the recipient s e mail address to the Available receivers list You may then use the finger icons to move e mail addresses to and from the Receivers list To edit an e mail address click the memo icon Note that the Available receivers list will already contain a list of names if you provided the DNS server information in the Network Settings tab Enter your own e ma
70. w side Switch mm mm mm mm mmm Ce DO 1 DO GND F 3 loLogik E2260 User s Manual Pinouts and Cable Wiring Output Channel DO PWR is for powering up the field Power LED Terminal Block Pin Assignments TB1 111111111 V V FG D D SG TB2 Power Input RS 485 dit i 02 631 4 5 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 TB2 F 4 G Accuracy Calibration The ioLogik E2260 achieves accuracy in temperature measurements as follows 1 At room temperature 25 3 C accuracy should be within 0 1 FSR The measurement range of a PT 100 sensor is 200 C to 850 C That means that readings are accurate to within 1 05 C If an object s temperature 1s measured at 100 C the actual temperature should be between 98 95 C and 101 05 C A reading of 600 C would include temperatures between 598 95 C and 601 05 C 2 Atan ambient temperature of 10 C or 60 C accuracy should be within 0 3 FSR If an object s temperature is measured at 100 C the actual temperature should be between 96 85 C and 103 15 C A reading of 600 C would include temperatures between 596 85 C and 603 15 C A calibrator such as provided by Yokogawa or Fluke is used for the standard signal source These products allow Moxa to guarantee accurate measurements to within 40 1 of FSR The actual error rates may differ between products For example when measuring a 500 C object one product might achieve accura
71. written as follows tftp 192 168 127 253 put ik2260_1 txt ik2260 txt tftp 192 168 127 254 put ik2260_2 txt ik2260 txt ATTENTION You can also run TFTP client software open the configuration file and enter the remote server s IP Note that both ASCII and Octet mode are supported When the download process is complete the I O server will reboot M WinTFTP Client Pro t x N L Upload Download Abort Settings About Remote server Local file name CMestyk221 DO Hat Sl Timeout E amp Remote file name Port s Yeon Block size 512 bytes Same a local 3 20 ioLogik E2260 Users Manual Utilities Using ioEventLog Installing ioEventLog 10EventLog is a Windows utility provided for the monitoring of the 1oLogik E2260 and attached I O devices It may be used from anywhere on the network to monitor the ioLogik E2260 1 Installation from CD Insert the Document and Software CD into the host computer Run SETUP EXE which is located in the root directory The installation program will guide you through the installation process and install the 10EventLog utility 2 Open ioEventLog After installation is finished run ioEventLog from Start gt Program Files gt Moxa gt IO Server gt Utility gt ioEventLog Basic Functions 10EventLog is installed along with ioAdmin form the Document and Software CD It is designed to help you keep a record of ioLogik status events over the network The log is stored on th

Download Pdf Manuals