1. 22 4 2 1 RS 422 Interface Connection Ne 22 4 2 2 RS 485 Interface Connection a eem eee 22 4 3 WIZ108SR Interface Board Schematic 23 5 coe s e ive des Ce E E eI E ek e e rise e 24 WIZ108SR User Manual WiZnet Co Ltd WiZnet Figures FIGURE 1 WIZ108SR INTERFACE csceccssesesscscsesscscscesccccscsecccseesescecsessesecsessececsessesecsessesessessecessesaecessesaecesseees 5 FIGURE 2 WIZ108SR CONNECTOR PIN ASSIGNMENT eene nennen nennen nennen nennen tenens 6 FIGURE 3 WIZ108SR CONFIGURATION TOOL NETWORK CONFIGURATION PAGE 7 FIGURE 4 SEARCHING WITH UDP BROADCAST METHOD 8 FIGURE 5 SEARCHING WITH TCP UNICAST METHOD eren 8 FIGURE 6 SIMPLE PING TEST PRO6RAM UI ener nennen tentent 9 FIGURE 7 WIZ108SR CONFIGURATION TOOL SERIAL CONFIGURATION PAGE 12 FIGURE 8 WIZ108SR CONFIGURATION TOOL OPTION CONFIGURATION 14 FIGURE 9 FILE OPEN DIALOG BOX FOR FIRMWARE UPLOADING I n 16 FIGURE 10 FIRMWARE UPLOADED SUCCESSFULLY es 17 FIGURE 11 SERIAL COMMAND FORMAT u tee teo cte dere 18 FIGURE 12 SERIAL COMMAND EXECUTING EXAMPLE sccccscsccscscssssesescecsecseseesesesesecsesessesesesecsessseaesececseseeaees 20 FIGURE 13 WIZ108SR DIMENSIONS UNIT MM 4 21 FIGURE 1
2. RI Reconnection interval client mode WIZ108SR User Manual WiZnet Co Ltd 18 Wiznet 0 65535ms LI 192 168 11 2 Local IP address SM 255 255 255 0 Subnet mask GW 192 168 11 1 Gateway DS 192 168 11 5 DNS server IP LP Local port number RP Remote host port number RH Remote host IP name BR 300 0 600 1 Baud rate refer to index DB 7 0 8 1 9 2 Data bit PR NONE 0 ODD 1 EVEN 2 parity SB 1 0 Stop bit FL NONE 0 XONXOFF 1 CTSRTS 2 Flow IT 0 65535 Inactivity timer 0 65535ms PT 0 65535 Serial data packing interval 0 65535 5 PS Packing size 0 255 PD Packing indicator 0 255 TE Enable 1 Disable 0 Software trigger enable flag SS software trigger fixed 3 bytes NP Connection password Max 8 bytes SP Search password 8 bytes Enable 1 Disable 0 Show serial input echo or not WIZ108SR is not supported this CMD LG Debug log message ER Error message SV Save setting message RT Reboot the device UN 0 00 0 0 UART counter EX m Exit from command mode Factory Reset Table 4 Serial command list WIZ108SR User Manual WZnet Co Ltd 19 WiZnet 3 3 Serial Command Executing Example Figure 12 shows an example with several commands executed At first
3. 01 02 03 L1192 168 11 2 L1192 168 11 20 LGSEG STARTED 4 AZ 0 01 18 ANSIW 115200 8 N 1 Figure 12 Serial command executing example WIZ108SR User Manual Co Ltd 20 WiZnet 4 Hardware Specification 4 1 WIZ108SR Dimension YSU Vis M N A 30 00 B 3 50 C 11 50 11 50 E 3 50 F 3 00 G 3 50 38 00 I 3 50 J 48 00 K 2 54 2 73 M 8 65 N 2 54 Figure 13 WIZ108SR Dimensions unit mm WIZ108SR User Manual Co Ltd Wiznet 4 2 WIZ108SR Signal Connection Method 4 2 1 RS 422 Interface Connection WIZ108SR Pin Header Signal RS 422 Device Figure 14 RS 422 Interface Connection Method 4 2 2 RS 485 Interface Connection WIZ108SR Pin Header Signal 485 RXD 485 RXD TXD TRXD P TRXD N RS 485 Device Figure 15 RS 485 Interface Connection Method WIZ108SR User Manual Co Ltd 22 Wiznet 4 3 WIZ108SR Interface Board Schematic 815 i i Figure 16 WIZ108SR Interface Board Schematic WIZ108SR User Manual Co Ltd 23 VIZnet 5 Warranty WIZnet Co Ltd offers the following limited warranties applicable only to the original purchaser This offer is non transferable WIZnet warrants our products and its parts against defects in materials and workmanship under normal use for period of standard ONE 1 YEAR for the WIZ108SR board and labor warranty afte
4. 3 Serial Configuration 3 1 Serial Command Format If WIZ108SR is in serial configuration mode users can use the following predefined commands to configure WIZ108SR via serial interface The format of serial command is shown in Figure 11 Each command starts with a command name 2 characters and ends with WrWn If the data field is null it means to read the value of the command on the contrary it means to write the value of the command Figure 11 Serial command format 3 2 Serial Command List The commands are listed in the following Table 4 Command Data Memo MC 00 08 DC 14 00 00 MAC address read only VR 1 0 Firmware version read only MN WIZ107SR or WIZ108SR Model name read only ST Opened 0 Connected 1 Upgrading 2 Device status read only IM STATIC 0 DHCP 1 PPPOE 2 Obtain IP method OP CLIENT 0 SERVER 1 MIXED 2 UDP 3 Operation mode DD ENABLE 1 DISABLE 0 DDNS enable disable flag CP ENABLE 1 DISABLE 0 Connection password enable disable flag PO RAW 0 TELNET 1 Data transmission protocol only raw data transmission is supported for current version DG ENABLE 1 DISABLE 0 Debug message output flag KA ENABLE 1 DISABLE 0 Keep alive flag KI Tx KeepAlive interval 0 65535ms KE KeepAliv nable interval 0 65535ms
5. If debug mode is on debug message can cause abnormal operation of the serial device Therefore just use this mode only for debug mode 2 COM port Setting The parameters of COM port of WIZ108SR are listed well in this page Users can set the COM port of WIZ108SR by selecting the value of each parameter in the drop down list By clicking the Setting button changed value can be applied 3 Serial data packing condition settings You can designate how the serial data can be packed to send to the Ethernet In default mode WIZ108SR checks the serial buffer and sends any received data to Ethernet without any standard Therefore the data can be regarded as error data due to WIZ108SR User Manual Co Ltd 12 WiZnet inconsistent data length In order to solve this problem the data from serial can be packed according to the specified condition before sending to Ethernet The condition is as below Time If there is not any new data during designated time all data in the serial buffer is converted to Ethernet packet If new data is received the time is re calculated and the received data is saved in the serial buffer Time condition can be utilized when the serial data size is variable and has no ending character but needs to be delivered in frame unit If the value is 0 option is not used Size When data is collected as much as the defined size in the serial buffer it is transmitted to Ethernet If the val
6. the UDP mode is selected the data from serial interface can be defined where to delivery via the Sever IP Address and Port and the WIZ108SR can also be defined where to receive Ethernet data from via the Remote Peer IP Address definition If the data destination and source are the same the two IP address will also be the same Please note the destination and source are using the same port 12 DDNS Setting DDNS function is not supported at current version WIZ108SR User Manual WZnet Co Ltd 11 WizZnet 2 1 2 Serial Configuration 2 WIZ107SR 108SR Configuration Tool Ver1 0 0 0 gt RQ Setting ovens au Reset Qu o E 4 Serialto Ethernet Network Serial 2 Options a 00 08 DC 01 02 03 Model WIZ108SR M Enable debug message output UART 1 2 COM port settings Firmware Version 1 0 Status OPEN Debug message Enabled Data 8 Baud Rate R 115200 Parity P NONE Stop Bit S 1 Flow Control F 3 Serial data packing condition settings Timer 0 0 65535ms 2 0 0 255 Bytes Character C 00 Hexacode Only 4 Serial command mode switch code Enable Trigger Code Hexacode Only Find 1 devices 00 08 DC 01 02 03 Figure 7 WIZ108SR Configuration Tool Serial Configuration Page 1 Enable debug message output If this mode is checked you can monitor the status of module and socket message like listen OK connect fail etc through serial terminal
7. 4 RS 422 INTERFACE CONNECTION METHOD U U nenne nnne nets 22 FIGURE 15 RS 485 INTERFACE CONNECTION METHOD nnne nete trennen 22 FIGURE 16 WIZ108SR INTERFACE BOARD SCHEMATIC U U U U U enne 23 WIZ108SR User Manual WiZnet Co Ltd WiZnet Tables TABLE 1 PRODUCT CONTENTS TABLE 2 WIZ108SR MODULE SPECIFICATION TABLE PIN HEADER CONNECTOR PIN ASSIGNMENT DESCRIPTION eese enne nennen 6 TABLE 4 SERIAL COMMAND LIST WIZ108SR User Manual WiZnet Co Ltd WIZnet 1 Introduction WIZ108SR 15 gateway module between RS 422 485 device and Ethernet It can transmit RS 422 485 data to Ethernet and vice versa With WIZ108SR you can connect your RS 422 485 device with Ethernet via WIZ108SR provides interface quite easier and shorten your development period to obtain more gains We also provide full functional configuration tools for WIZ108SR You can set WIZ108SR upon your needs by using serial configuration command when WIZ108SR is in serial configuration mode or using provided configuration tool via Ethernet to make WIZ108SR embedded in your products well 1 1 Key Features m Compact Sized RS422 485 to Ethernet Quick and Simple Internet Connection to Serial Devices m Supporting Firmware Customization according to Customer s Requirement W Guarantee Stable and Reliable Data Communication by using W7100 One chip sol
8. CP PPPoE Subnet mask 255 255 255 0 Gateway 192 168 11 1 DNS server 0 0 0 0 PPPoE ID PPPoE password Show chars 1 1 Select operation mode for the device client server TCP mixed UDP Remote IP host name 12 DDNS settings Enable Hostname MidnightCow DDNS Port number DDNS ID DDNS password Find 1 devices 00 08 DC 01 02 03 Figure 3 WIZ108SR Configuration Tool Network Configuration Page 1 Search The Search function is used to search all devices existing in the same LAN or one specified one device in WAN By using UDP broadcast as shown in Figure 4 all connected devices in the same subnet will be found If the TCP unicast method is checked the specified IP address must be given as shown in Figure 5 The founded device will be listed in the Serial to Ethernet tree with its MAC address Please note the identification code must be input if the device has been configured with one identification code WIZ108SR User Manual Co Ltd 7 WizZnet Input device search identification code Input code Remember me Delete Show character Search method UDP broadcast unicast Broadcast will find the all devices with the same identification code in the same subnet Search Q Close Figure 4 Searching with UDP broadcast method Input device search identification code Input code Remember me Delete Show character Search meth
9. Model name Firmware version Etc 10 Network Setting Method Select IP setting mode you can select one of Static DHCP PPPoE mode is not supported at current version Using the follow IP Address Static This is option for setting WIZ108SR module s IP with static IP address Firstly select MAC address which you wanted to set as static IP in the board list Then Device Subnet Gateway box will be enabled Input Static IP address and click setting button Then set the IP address as you want DHCP Set this option to use DHCP mode Firstly check DHCP and click Setting button If IP address is successfully acquired from DHCP server the MAC address will be WIZ108SR User Manual Co Ltd 9 WiZnet displayed on the configuration window It takes some time to acquire IP address from DHCP server When a module on the board list is selected IP address Subnet mask and Gateway are displayed If module could not acquire network information from DHCP server IP address Gateway Address and Subnet mask will be initialized to 0 0 0 0 11 Network Operation Mode Client server mixed This is to select the communication method based on TCP TCP is the protocol to establish the connection before data communication but UDP just processes the data communication without connection establishment The Network mode of WIZ108SR can be divided into TCP Server TCP Client and Mixed mode according to the connection establishing
10. WIZ108SR should be set into serial configuration mode both hardware trigger and software trigger can be used For hardware trigger the trigger should be turned on and reset the WIZ108SR and the software trigger code should be sent to change WIZ108SR into serial configuration mode Please note the EC command is not supported for WIZ108SR so echo back is not displayed In this example we using software trigger to set WIZ108SR into serial configuration mode And then the user inputs command MC with Enter key pressed to read the MAC address of the WIZ108SR You can find that the WIZ108SR responses with MC00 08 DC 01 02 03 In the same way we can read the IP address of WIZ108SR This example also shows how to modify the parameters of WIZ108SR After reading IP address the user inputs LI192 168 11 20 with Enter key pressed in hyper terminal You can find that the IP address is set to 192 168 11 20 after LI command executed correctly Please note the SV command must be executed if you want to save your new parameters And the EX command is used to leave the serial configuration mode Please note that the data connection will be closed firmly once the WIZ108SR goes into serial configuration mode test ol lid ELLII amp LGWIZ108SR VERT 0 STARTED LGHWSW LGMAC 00 08 DC 01 02 03 LGGW 192 168 11 1 LGSN 255 255 255 0 LGIP 192 168 11 2 LGSEGCP TCP STARTED LGSEGCP UDP STARTED MC00 08 DC
11. WiIZnet WIZ108SR User Manual Version 1 0 WiZnet 2010 WIZnet Co Ltd All Rights Reserved For more information visit our website at http www wiznet co kr WIZ108SR User Manual WIZnet Co Ltd WiZnet Document Revision History Date Revision Changes 2010 04 23 V1 0 Official Release WIZ108SR User Manual WiZnet Co Ltd WIZnet WIZnet s Online Technical Support If you have something to ask about WIZnet products write down your question on Q amp A Board in WIZnet website www wiznet co kr WIZnet will give an answer as soon as possible Wiznet PRODUCTS TECHNOLOGY lt website TECHNICAL Q amp A Renewal Open with LIBRARY 3 2 2 0 concepts ENGLISH CHINESE APANESE KOREAN Onine Mall DISTRIBUTOR ut Easy to check new or amended info thru What s updated board Support RSS in each board Enhance Search function Open Blog amp Community menu Build Technical forum well as Q amp A Easy to find local distributors WIZnet own innovation spirit visualized Chinese version Grand Open Japanese version Coming Soon BLOG ABOUT US CLOSE NEW PRODUCT ment AW Compliant uctic W5300 W 20 CIRCUITCELLAR New Product N COMPANY OVERVIEW DISTRIBUTOR Conner W5100 enter WiZnet 3rd Party e market place WiZnet e sale International Winners Sep 9 11 2008 Sales Materi
12. als www WIZwiki net www ewiznet com TTIGN CONTEST WL Mau Taiwan Booth 2106 25 WiZwiki tistory com COPYRIGHT NOTICE Copyright 2010 WIZnet Ltd All Rights Reserved Technical Support support Qwiznet co kr Sales amp Distribution sales Qwiznet co kr For more information visit our website at http www wiznet co kr WIZ108SR User Manual WiZnet Co Ltd WiZnet Table of Contents 1 o LE Coro Teo o EU 1 1 1 Lu cSp 1 12 Product Contents WIZ108SR EVB 2 1 3 Product Specification reete 4 1 3 1 WIZ108SR Module Specification 2 4 1 3 2 WIZ108SR Module Interface 5 1 3 3 Pin Header Connector Pin Assignment RN 6 2 Getting Started Lm 7 2 1 Contigurati n TOOL 7 2 1 1 Network Configuration 7 2 1 2 Serial Configuration ie ted ett aei baee a eee va dd 12 2 1 3 Option Configuratio 14 2 2 a 16 3 Serial Configuration 18 3 1 Serial Command Format erhebt ev ge eee tenet 18 3 2 Serial Command ibi reete been e RR vt veu r Veg ee dp Eve doe 18 3 3 Serial Command Executing EXample pp 20 4 Hardware Specification 21 4 1 WIZ108SR DIMENSION tii E 21 4 2 WIZ108SR Signal Connection
13. efinition of the connector are introduced in Figure 2 and the specification of each pin is described in Table 3 1 VCC 2 VCC 3 485 RXD 4 nRESET D 5 485 RXD 6 nFAC RST 7 TXD 8 HW_TRIG E 9 TXD 10 485 SEL HEADER 6x2 2 54mm pitch 11 GND 12 GND Figure 2 WIZ108SR Connector Pin Assignment Pin Number Signal Description 1 VCC System Power input 3 3V 2 VCC System Power input 3 3V 485 RXD RS 485 TRXD RS 422 RXD 4 nRESET System Reset signal input Active Low 485 RS 485 TRXD RS 422 RXD 6 nFAC RST Factory Reset signal input Active Low 7 TXD RS 422 TXD 8 HW TRIG Hardware Trigger signal input Low CMD mode 9 TXD RS 422 TXD 3 485 SEL RS 422 485 Select Pulled Low RS 422 Floating RS 485 11 GND System Ground 12 GND System Ground Table 3 Pin Header Connector PIN Assignment Description WIZ108SR User Manual WZnet Co Ltd 6 WizZnet 2 Getting Started 2 1 Configuration Tool 2 1 1 Network Configuration gt WIZ107SR 108SR Configuration Tool Yer1 0 0 0 3 5 6 8 see setna Grad mm QU aa 4 Serialto Ethernet Network Serial Options 4 00 08 0 01 02 03 i i Model Name WIZ108SR UART 1 Firmware Version 1 0 Device IP address 192168 11 2 15000 Status OPEN Debug message Enabled 10 Device network settings Using the follow IP Address DH
14. luded in W7100 Auto negotiation Full duplex and Half duplex Auto MDI MDIX Serial RS 422 RS 485 MCU Architecture Included in W7100 Fully software compatible with industrial standard 8051 Internal 2KBytes Boot ROM Internal 64KBytes embedded program FLASH memory Internal 256Bytes embedded data FLASH memory Internal 64KBytes embedded SRAM Internal 32KBytes memory for TCP IP data communication Interface Included RS 422 485 Transceiver Signals RS 422 TXD TXD RXD RXD RS 485 TRXD TRXD Serial Parameters RS 422 RS 485 Interface select RS 485 Direction control Speed Up to 230Kbps Dimensions 48mm x 30mm x 18mm Include connector size Connector type 2 54mm Pitch Pin header 12Pin 2 6 Input voltage Power consumption Temperature DC 3 3V Under 250mA 0 70 C Operation 40 C 85 C Storage Humidity 10 9096 Table 2 WIZ108SR Module Specification WIZ108SR User Manual WZnet Co Ltd WIZnet 1 3 2 WIZ108SR Module Interface g Ethernet Port 295 RJ 45 Connector W7100 RS 422 485 amp 3 Power Indicator LED Control Signals RS 422 485 Transceiver Figure 1 WIZ108SR Interface WIZ108SR User Manual Co Ltd 5 Wiznet 1 3 3 Pin Header Connector Pin Assignment WIZ108SR provides an external connector to connect it with your application board The pin assignment and d
15. method At the TCP server mode WIZ108SR operates as server on the process of connection and waits for the connection trial from the client WIZ108SR operates as client at the TCP Client mode on the process of connection and tries to connect to the server s and Port Mixed modes supports both of Server and Client The communication process of each mode is as below lt TCP server mode Communication gt At the TCP Server mode WIZ108SR waits for the connection requests TCP Server mode can be useful when the monitoring center tries to connect to the device where WIZ108SR is installed in order to check the status or provide the commands In normal time WIZ108SR is on the waiting status and if there is any connection request SYN from the monitoring center the connection is established ESTABLISH and data communication is processed Data Transaction Finally connection is closed FIN In order to operate this mode Local IP Subnet Gateway Address and Local Port Number should be configured first The Data transmission proceeds as follows 1 The host connects to the WIZ108SR which is configured as TCP Server mode 2 As the connection is established data can be transmitted in both directions from the host to the WIZ108SR and from the WIZ108SR to the host lt TCP client mode Communication gt If WIZ108SR is set as TCP Client it tries to establish connection to the server To operate this mode Local IP Subnet Gatewa
16. nter into waiting status 2 Search identification code For the security issues WIZ108SR can have its own password for searching The password is stored in the EEPROM of WIZ108SR and it can be modified via this configuration tool The password can be any alphabet or number Its length can be variable and its maximum length is 8 bytes The password is case sensitive 3 Connection password This function is available only when WIZ108SR works in server mode If this function is enabled the remote client should send the password to WIZ108SR before data transmission Please note the password is case sensitive 4 Network protocol settings There are two kinds of data transmission protocol one is raw data transmission and the other is using Telnet RFC2217 But in current version only the raw data transmission is supported If the Keep alive function is enabled WIZ108SR will send keep alive packet in every user set minutes if no reply received after the user set period WIZ108SR User Manual Co Ltd 15 Wiznet 2 2 Firmware Upload 1 Run the Configuration Tool program and click Search button and input search password in the password popup dialog if you set the search password 2 If the module is properly connected to the network then MAC address will be displayed on the Serial to Ethernet search result area 3 Select a MAC address shown in search result and click Upload button Before
17. od O UDP broadcast 9 TCP unicast Host name IP 192168 11 2 Qs Figure 5 Searching with TCP unicast method 2 Setting This function is to complete the configuration change If you select the MAC Address from the Serial to Ethernet tree the default configuration value of the module will be displayed Change the configuration and click Setting button to complete the configuration The module will re initialize with the changed configuration Changed value is saved in the EEPROM of the module Thus the value is not removed even though power is disconnected 3 Upload Firmware will be uploaded through network WIZ108SR User Manual Co Ltd WiZnet 4 Reset Reset and restart the selected module if you select the MAC Address from the tree and click Reset button 5 Factory All value is initialized to Factory default value if you select the MAC Address from the tree and click Factory button 6 Ping Popup the Simple Ping application program you can test the ping operation Trying to ping 192 168 11 2 Ping Reply 16 msec Ping Remote host name IP address 192 168 11 2 Figure 6 Simple Ping Test Program 7 Firewall Popup the Windows Firewall setup program 8 Exit Close the configuration Tool Program 9 Search window If you click Search button all the MAC address same subnet will be displayed this area You can see the basic information such as
18. r the date of original retail purchase During this period WIZnet will repair or replace a defective products or part free of charge Warranty Conditions 1 The warranty applies only to products distributed by WlZnet or our official distributors The warranty applies only to defects in material or workmanship as mentioned above in 6 Warranty The warranty applies only to defects which occur during normal use and does not extend to damage to products or parts which results from alternation repair modification faulty installation or service by anyone other than someone authorized by WIZnet Inc damage to products or parts caused by accident abuse or misuse poor maintenance mishandling misapplication or used in violation of instructions furnished by us damage occurring in shipment or any damage caused by an act of God such as lightening or line surge Procedure for Obtaining Warranty Service 1 3 Contact an authorized distributors or dealer of WIZnet Inc for obtaining an RMA Return Merchandise Authorization request form within the applicable warranty period Send the products to the distributors or dealers together with the completed RMA request form All products returned for warranty must be carefully repackaged in the original packing materials Any service issue please contact to sales wiznet co kr WIZ108SR User Manual Co Ltd 24
19. twork protocol settings Use row data transmission algorithm Use Telnet RFC2217 Send Keep alive every sec ifno reply every sec Find 1 devices 00 08 DC 01 02 03 Figure 8 WIZ108SR Configuration Tool Option Configuration Page 1 Timer interval Inactivity Timer The connection holding period when no data transmission Reconnection Interval The connection retry interval client mode only After the connection is established if there is not data transmission within the time defined in Inactivity time the connection is closed automatically The default value is 0 If 0 is set this function is not activated In this default setting the connection is maintained even though there is no data transmission In order to close the connection the Close command should be given This function can be used for more than two or more systems to connect to a WIZ108SR module If one system holds the connection to the WIZ108SR other systems cannot connect to the module If there is no data transmission during the time defined in Inactivity time the connection will be closed for other system to be connected WIZ108SR User Manual Co Ltd 14 WiZnet Inactivity Time also can be useful for the case when the server system is unexpectedly shut down In this status if there is not any data communication during the time defined in the Inactivity time WIZ108SR will close the connection and e
20. ue is 0 option is not used Character The data is collected in the serial buffer until specified character is received and transmitted to Ethernet The character can be specified in Hex formation The value is 0 this option is not used One of three conditions is satisfied the data is transmitted to the Ethernet Ex Delimiter Size 10 Char 0x0D Serial data 0123456789abc Ethernet data 0123456789 i abc data remains in the serial buffer of module 4 Serial command mode switch code This function is for module configuration not through network with Configuration tool but through serial communication At the default status the serial command mode is disabled When you want to set via serial communication check enable WIZ108SR User Manual WZnet Co Ltd 13 WizZnet 2 1 3 Option Configuration 4 WIZ107SR 108SR Configuration Tool Ver1 0 0 0 gt RQ Setting Q ovens au Reset Qu Pina Ge Serialto Ethernet 0 Network Serial Options 4 00 08 DC 01 02 03 E 5 Model Name WIZ1085R 1 Timer interval UART 1 Inactivity Timer 0 0 65535 Seconds Firmware Version 1 0 Status OPEN Debug message Enabled Reconnection interval The connection holding period when no data transmission The connection retry interval Client mode only 2 Search identification code Code Max 8 bytes L Show Chars 3 Connection password TCP server mode only Ll Enable Password Show Chars Ne
21. uploading through Ethernet you should set the network information of WIZ108SR first by Configuration Tool program 4 When the window as shown below Figure is displayed select file for upload and click Open button not upload any other files except for WIZ108SR application firmware file XKD OD Firmware APPO100 bin WIZ108SR 0100 bin 3 WIZ1085R 0100 BP WIZ1085R FW VI D zip APPO100 bin All files Figure 9 File open dialog box for Firmware uploading WIZ108SR User Manual WZnet Co Ltd 16 Wiznet 5 When the firmware is uploaded successfully the following message box will be shown w WIZ107SR 108SR Configuration Tool Yer1 0 0 0 sean gt Setting ones x Reset Qus Gen Que Q 4 Serialto Ethernet Network Serial o Options a 00 08 DC 01 02 03 Model Name WIZ1085R UART 1 Firmware Version 1 0 Device IP address 192158112 Status OPEN E Debug message Enabled Device network settings Using the follow IP Address DHCP Subnet mask 255 255 255 0 Gateway 192 168 11 1 O Show chars e device server mixed UDP Remote IP host name DDNS settings Enable Hostname MidnightCow DDNS Port number 3030 DDNS ID DDNS password Find 1 devices 000000000000000000000 c0 08 DC 01 02 03 Figure 10 Firmware uploaded successfully WIZ108SR User Manual WZnet Co Ltd 17 Wiznet
22. ution W Provide User Friendly Configuration Tool Program m Support User Password for Security Support Serial Command for Serial configuration m 10 100 Mbps Ethernet amp Max 230Kbp Serial Interface Support IP Configuration Static DHCP m Support DNS B Compact design 48mm X 30mm X 18mm LxWxH B RoHS Compliant WIZ108SR User Manual WZnet Co Ltd 1 Wiznet 1 2 Product Contents WIZ108SR EVB model WIZ108SR WIZ108SR Interface Board 12pin Cable Connect WIZ108SR with Interface Board LAN Cable WIZ108SR User Manual Co Ltd WiZnet Data CD Manual H W amp S W materials inside Table 1 Product Contents Tf there is any missing item contact to the shop where you purchased WIZ108SR User Manual Co Ltd 3 Wiznet 1 3 Product Specification 1 3 1 WIZ108SR Module Specification WIZ108SR feathers our fast hardwired TCP IP stack and most of TCP IP protocols such as TCP UDP IP ARP ICMP IGMP and Ethernet MAC are all supported 10Mbps and 100Mbps Ethernet are all supported and one standard Ethernet Jack is mounted in WIZ108SR One serial port is provided in WIZ108SR via 12 pin connector which feathers standard RS 422 485 specification WIZ108SR can be powered by a DC 3 3V power supply with at least 250mA current supply The detailed specifications are listed in Table 2 TCP IP W7100 PHY Inc
23. y Address Server IP and Server port WIZ108SR User Manual Co Ltd 10 WiZnet number should be set If server IP had domain name use DNS function In TCP Client mode WIZ108SR can actively establish a TCP connection to a host computer when power is supplied The Data transmission proceeds as follows 1 As power is supplied WIZ108SR board operating as TCP client mode actively establishes a connection to the server 2 If the connection is complete data can be transmitted in both directions from the host to the WIZ108SR and from WIZ108SR to the host lt Mixed mode Communication gt In this mode WIZ108SR normally operates as TCP Server and waits for the connection request from the peer However if WIZ108SR receives data from the serial device before connection is established it changes to the client mode and sends the data to the server IP Therefore at the mixed mode the server mode is operated prior to the client mode As like TCP Server mode the Mixed mode is useful for the case that the monitoring center tries to connect to the serial device in which WIZ108SR is used to check device status In addition to this if any emergency occurs in the serial device the module will change to Client mode to establish the connection to the server and deliver the emergency status of the device lt Use UDP mode gt UDP is not connection oriented protocol But the communication port should also be defined well If

Download Pdf Manuals

image

Related Search

Related Contents

Denon AVR-886 Stereo Receiver User Manual  Samsung SP-P410M Käyttöopas  日本翻訳ジャーナル 翻 訳 の 未 来 を 考 え る    GRANPOWER5000 モデル 280 取扱説明書の追記と修正  Yamaha PortaSound PSS-12 Owner's Manual  Philips SPC2050NC Pro for laptops Webcam  EN Operating Instructions  Folding Fitness Trampoline User`s Manual  kf 937 ud kf 937 ud kf 937 ud kf 933 – kf 933 u  