1. The SF2 supports full duplex and half duplex operation with auto negotiation high speed non blocking store and SF2 Data Sheet 2013 04 19 forward switching Quality of Service QoS support with four traffic classes IEEE 802 1p and three level 802 1x security as well as the logical segmentation of ports 802 1q VLANs The switch is fault tolerant and restores itself on its own If a link is temporarily unavailable frames can be sent via backup redundant links spanning tree protocol link aggregation and no data loss occurs Its built in test mechanisms make the SF2 an even more reliable component in the communication system In addition the switch can act as Power over Ethernet PoE Power Sourcing Equipment PSE supplying other devices on ports 1 and 2 with power The SF2 was specifically designed for rugged mobile communication systems with high demands It is thus for example fully compliant with the EN 50155 railway standard All components inside the cassette are specified for a 40 to 70 C operation temperature 85 C for ten minutes according to EN 50155 Class Tx There are no socketed components hardening the box against shock and vibration Its PCBs are ready for coating and the switch has a guaranteed minimum standard availability of 5 years MeN Page 1 Diagram Front gt connector Power Supply Unit Local Supply Voltage Supervisor PoE Control Port 1 lt P Port 2 Gees d E Configurat
2. and v6 TFTP REC 1350 VLAN port based VLANs GVRP MVRP IEEE 802 1Q Rev D5 0 2005 Power over Ethernet functions on ports 1 and 2 o PSE Power Sourcing Equipment function o Supplies one PD class 0 device or two PD class 2 devices up to 15W total 9 pin D Sub connector at front RS232 V24 BC interface for external dongle Page 3 Technical Data Front I O Electrical Specifications Mechanical Specifications Environmental Specifications MTBF Safety EMC Conformity Software Support SF2 Data Sheet 2013 04 19 Eight Ethernet ports via RJ45 connectors One service interface via 9 pin D Sub plug connector One power input via mixed 7 pin D Sub plug connector Sixteen link and activity Ethernet status LEDs two per channel Four Power over Ethernet status LEDs two each for ports 1 and 2 Status LEDs for power reset and error codes Power supply unit o 14 4 154 VDC wide range according to EN 50155 Isolation according to EN 50155 o Input output 1500 Vrms Input shield 1500 Vrms 7W2 D Sub power connector 1000 Vrms Output shield 1500 Vrms Ground shield 1500 Vrms Service connector 1000 Vrms Power consumption 24 W incl 15 W PoE DD DD 19 rack mount standard Dimensions 3U 18HP 168 mm depth Weight 870 g Temperature range operation o 40 70 C qualified components 85 C for ten minutes according to EN50155 Class Tx Temperature range storage 40 85 C Relative
3. humidity operation max 95 non condensing Relative humidity storage max 95 non condensing Altitude 300 m to 3 000 m Shock according to EN 60068 2 27 Bump according to EN 60068 2 29 Vibration sinusoidal according to EN 60068 2 6 381 460 h 40 C according to IEC TR 62380 RDF 2000 Flammability o PCBs manufactured with a flammability rating of 94V 0 by UL recognized manufacturers EN 55022 radio disturbance EN61000 4 2 ESD Immunity IEC 61000 4 4 burst IEC 61000 4 5 surge Firmware for configuration and management included Page 4 Configuration amp Options Standard Configurations Article No 19SF01 00 19SF02 00 19SF03 00 19SF04 00 Options Ethernet powered version without PSU on request Environmental specifications Connectors RJ45 RJ45 M12 M12 Front Panel Management Power over Ethernet 18 HP Unmanaged Yes PSE on ports 1 and 2 18 HP Managed Yes PSE on ports 1 and 2 22 HP Managed Yes PSE on ports 1 and 2 22 HP Unmanaged Yes PSE on ports 1 and 2 Class 2 Powered Device supplied via Ethernet Port 1 o No internal power supply unit Conformal coating on request Ordering Information Standard SF2 Models Related Hardware Miscellaneous Accessories Software Firmware BIOS 19SFO2 00 05SFO2 00 19SFO1 00 19SF03 00 19SF04 00 05SFO2 00 14ETSW 00 Managed Switch with 8 Fast Ethernet ports on RJ45 PoE PSU 18HP 40 85 C with qualifie
4. SF2 3U 19 Managed 8 Port Industrial Ethernet Switch Managed 8 port rugged Ethernet switch 3U 18 HP 19 rack mountable 8 Fast Ethernet ports on RJ45 connectors Power over Ethernet PSE functionality Configuration via Telnet CLI SNMP ver 3 or external dongle E Service interface via D Sub E LEDs for port PoE and board states E Wide input range PSU 14 4 to 154 V EN 50155 qualified 40 to 70 85 C according to EN 50155 Class Tx with qualified components The SF2 is a stand alone managed industrial Fast Ethernet switch that comes in a compact 3U 18HP 19 cassette It provides eight channels at the front panel accessible through RJ45 connectors It is supplied by its integrated rugged power supply unit PSU with a power connector at the front panel The entire switch consumes less than 7 W and needs no cooling The SF2 is managed by its own PowerPC CPU that integrates the management firmware A service port is accessible at the front panel on a D Sub connector providing an easy way to configure the switch A command line interface is available via the RS232 at the service port and over Ethernet via Telnet or Secure Shell SSH The switch can also be configured via SNMP version 3 Additionally the service connector can be used to attach an external dongle to store or update the switch configuration This makes it easy to exchange the unit for service purposes All of the ports are individually configurable
5. d components 12C dongle for F302 G302 and managed SFxx switches 512Kb D Sub 40 85 C Unmanaged Switch with 8 Fast Ethernet ports on RJ45 PSU 18HP 40 85 C with qualified components Managed Switch with 8 Fast Ethernet ports on M12 PoE PSU 22HP 40 85 C with qualified components conformal coating Unmanaged Switch with 8 Fast Ethernet ports on M12 PSU 22HP 40 85 C with qualified components conformal coating 12C dongle for F302 G302 and managed SFxx switches 512Kb D Sub 40 85 C Ethernet Switch Firmware for managed RSx SFx F302 and G302 models For operating systems not mentioned here contact MEN sales Documentation SF2 Data Sheet 2013 04 19 Compare Chart Industrial Ethernet switches for different platforms Download 20SFO2 00 21ETSW 00 21ETSW 01 21ETSW ER SF2 SF3 User Manual Managed Ethernet Switch Quick Start Guide Managed Ethernet Switch Command Line Interface User Manual Command Reference 14ETSW 00 Managed Ethernet Switch Firmware Errata Page 5 Contact Information Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SAS MEN Micro Inc Neuwieder Stra e 3 7 18 rue Ren Cassin 860 Penllyn Blue Bell Pike 90411 Nuremberg ZA de la Chatelaine Blue Bell PA 19422 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 Phone 33 0 450 955 312 Fax 215 542 9577 Fax 33 0 450 955 211 info men de info men france fr sales me
6. ion z Port 4 Switch Device EEPROM Management Port 5 lt P 10 100Base T CPU Port 7 lt P Port 8 Service PCP DDR2 SDRAM SF2 Data Sheet 2013 04 19 Page 2 Technical Data Key Features Management Firmware System Features Management Firmware Security Features Supported Protocols and Standards Power Over Ethernet Features Service Interface SF2 Data Sheet 2013 04 19 Simple Switch replacement configuration can be done via external dongle without any tools High speed non blocking store and forward switching Eight 10 100Base T ports at front panel Electrical isolation 1500 Vrms Port configuration copper 10 100 Mbit s Auto negotiation Auto MDI MDIX crossover on all ports manual configuration possible Layer2 based Policy Control List 8K MAC address lookup table with automatic learning and aging Up to 4096 VLAN Rapid Spanning Tree Protocol and Multiple Spanning Tree Protocol to ensure loop free topology formation Reducing multicast traffic in the network through multicast snooping IGS IPv4 and MLDS IPv6 Saving and restoring user configurations Software upgrades through TFTP System logs syslog and e mail alerts for critical events Remote monitoring RMON and alarm generation Displaying the running configuration in the form of CLI commands Management interfaces through o CLI RS232 console Telnet SSH o SNMP v3 Switch configuration can be loaded from external dongle User authe
7. nmicro com www men de www men france fr www menmicro com The date of issue stated in this data sheet refers to the Technical Data only Changes in ordering information given herein do not affect the date of issue All brand or product names are trademarks or registered trademarks of their respective holders MEN is not responsible for the results of any actions taken on the basis of information in the publication nor for any error in or omission from the publication MEN expressly disclaims all and any liability and responsibility to any person whether a reader of the publication or not in respect of anything and of the consequences of anything done or omitted to be done by any such person in reliance whether wholly or partially on the whole or any part of the contents of the publication The correct function of MEN products in mission critical and life critical applications is limited to the environmental specification given for each product in the technical user manual The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer Should the customer purchase or use MEN products for any unintended or unauthorized application the customer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmles
8. ntication using IEEE 802 1x Controlling management access through SNMP and CLI only from authorized managers MAC based and IP based access list ACL for traffic filtering Rate limiting and storm control to prevent packet flooding from malicious peers DHCP client server relay IEEE 1394 Ethernet flow control IEEE 802 3x GARP VLAN aware bridging GVRP GMRP support IEEE 802 1D 2004 Hypertext Transport Protocol HTTP Server for Remote Management and Monitoring RFC2626 HTTP Secure HTTPS HTTP based Remote Management over encrypted data channel RFC2818 IGMP snooping IGMP proxy IGMP Querier MLD Discovery RFC 4541 Link aggregation LACP EtherChannel IEEE 802 3ad 2005 Link Layer Discovery Protocol LLDP IEEE 802 1ab 2005 Multiple Spanning Tree MSTP IEEE 802 1s Path MTU Discovery Protocol PMTUD RFC 1984 Priority based switching Quality of Service DiffServ tagged frames Layer2 based 801 1Q VLAN ID packet routing IEEE 802 1p Port based authentication with EAP IEEE 802 1x REV2004 RFC3748 Port based authentication on registered MAC Address Lists Power over Ethernet support IEEE 802 3af IEEE 802 3at Type 1 Rapid Spanning Tree Protocol RSTP IEEE 802 1w Remote Network Monitoring Information Base v1 RFC2819 Secure Shell SSH for Remote Configuration CLI over secure channel Secure Sockets Layer Encrypted Data Exchange RFC5246 SNMP v1 v2c v3 management Syslog RFC 5424 TCP IP v4
9. s against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part In no case is MEN liable for the correct function of the technical installation where MEN products are a part of Copyright 2015 MEN Mikro Elektronik GmbH All rights reserved SF2 Data Sheet 2013 04 19 Page 6

Download Pdf Manuals

image

Related Search

Related Contents

Kensington KeyFolio Exact Plus  www.tescoma.com/video/630876 1 2 3 4 5 6 8 9 10 11 12 7  CommandPoint  Les effets de l`admission en EHPAD sur le mode alimentaire des  NetBurner SB72EX User's Manual  AL20081124  Adaptador Bahía Frontal 3.5in Lector para Tarjetas  Brother MW-140BT Printer User Manual    