1. ezm SURGE PROTECTION 8 5 15R OUTPUT RECEPTICLES CIRCUIT BREAKER 70 1500 2000 REAR VIEW Installation amp Initial Startup Note Before installation inspect the unit and packaging to make sure that nothing inside has been damaged Placement amp Storage Install the UPS in a protected area that is free of excessive dust and has adequate air flow Place the UPS away from other units at least 7 8 in 20 cm to avoid interference DO NOT operate the UPS where the temperature and humidity is outside the specified limits See Specifications for details Xtreme Power Conversion XPC Corporation 6 S70 SERIES USERS MANUAL V2 Connect UPS to Utility and Charging Before the initial use of the UPS plug the UPS input cord into a wall outlet and turn the UPS on by depressing the Power switch on the front of the UPS For best results the batteries in the UPS should be charged for at least 6 hours before use The UPS charges its battery while it is connected to AC utility power and powered on Connecting the Loads Plug the loads to be supported by the UPS into the output receptacles on the rear of the UPS Simply turn the power switch on the UPS on and the devices connected to the UPS will be protected by the UPS unit CAUTION NEVER connect a laser printer or scanner to the UPS This may cause damage to the unit Connect Modem Phone for Surge Protection S70 1000 1500 2000 model
2. 500 ft 3500 m above sea level AC Mode Battery Mode Load Level Battery Level Input Voltage Output Voltage Overload Fault Low Battery Xtreme Power Conversion XPC Corporation 12 S70 SERIES USERS MANUAL V2 Obtaining Service If the UPS requires Service 1 Use the TROUBLESHOOTING section in this manual to eliminate obvious causes 2 Verify there are no circuit breakers tripped 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call Xtreme Power Conversion Corp Technical Support at 800 582 4524 Technical support inquiries can also be made at support xpcc com Please have the following information available BEFORE calling the Technical Support Department a Your name and address b The serial number of the unit c Where and when the unit was purchased d All of the model information about your UPS e Any information on the failure including LED s that may or may not be illuminated f A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the or
3. XPC reserves the right to require you to transfer title and deliver the Connected Equipment to XPC if it chooses to reimburse you for the fair market value of the Connected Equipment XPCs maximum liability shall be reduced to reflect all such other payments or sources of recovery whether applied for or not 4 If XPC issues payment to you to have the Connected Equipment repaired the repair must be performed at a service center that is authorized by the manufacturer of the Connected Equipment XPC reserves the right to contact the authorized service center directly to discuss repair costs and damage to the Connected Equipment to determine if it was caused by a Power Disturbance and the right to request that the service center forward the Connected Equipment or components of the Connected Equipment to XPC for inspection 5 Unless modified in writing signed by an officer of XPC and you the terms of this policy are the complete and exclusive agreement between the parties superseding all prior agreements oral or written and all other communications between the parties relating to the subject matter of this agreement No employee of XPC or any other party is authorized to make any representations beyond those made in this agreement concerning the Load Protection Policy XPC Corporation 230 Yuma Street Denver Colorado 80223 1 800 582 4524 Xtreme Power Conversion XPC Corporation 17 S70 SERIES USERS MANUAL V2 For more information about X
4. is directly connected to the product Only those devices registered in that manner will be covered Xtreme Power Conversion XPC Corporation 15 S70 SERIES USERS MANUAL V2 2 All Connected Equipment must be UL or CSA approved 3 The Product must be plugged into a properly wired and grounded outlet Use of input surge devices extension cords adapters ground wires or electrical connections not manufactured by XPC voids the XPC Load Protection Policy No other surge protection device may be connected to the output sockets of the Product The installation must comply with all applicable electrical and safety codes set forth pursuant to the NEC 4 The Product must have undeniable physical evidence of a Power Disturbance that directly and proximately caused the damage 5 The Connected Equipment must have been damaged by a Power Disturbance on a properly installed grounded and National Electric Code NEC code compliant 120 208 240 volt AC power line in the United States or Canada by a Power Disturbance on standard telephone land line or PBX telephone equipment line that is properly installed and connected to an RJ11 port on the Product or by a Power Disturbance on a standard Local Area Network connection that is properly installed and connected to an RJ45 port on the Product and d is directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturbance pass
5. the load from the output of the UPS Charge the UPS at least 8 hours Replace the battery with the same type of battery Reconnect the input power cord properly Xtreme Power Conversion XPC Corporation 10 S70 SERIES USERS MANUAL V2 Specifications 70 500 S70 700 70 1000 S70 1500 S70 2000 120VAC 81 145 500VA 700VA 1000VA 1440VA 2000VA 300W 420W 600W 900W 1200W 60 Hz auto sensing 120VAC 108 132 Simulated sine wave OUTPUT 60 1 Hz 2 6ms Typical Sealed Maintenance free lead acid 1 12V 1 12V 2 12V 2 12V BATTERY i 7AH 9AH 7AH 9AH 4 6 hours to 90 capacity USB Black Plastic Included in ViewPower CD USB cable Manual box 3 9 x 11 3 x 5 6 in gt 7 au 5 7 x 15 6 x 8 1 in 100 x 287 x 142 446 x 350 x 160 149 x 397 x 205 mm mm mm ae 5 5 x 13 1 x87 in X s x 10 0 9 1 x 19 3x 11 3 in 140 x 332 220 roo x442 x 254 230 x 490 x 287 mm mm mm 9 5 Ibs 10 8lbs 17 6 Ibs 24 5 lbs 25 4 Ibs 4 3 kg 4 9 kg 8 0 kg 11 1 kg 11 5 kg PHYSICAL ippi 10 1 Ibs 11 5 Ibs 19 4 Ibs 27 1 Ibs 28 0 Ibs i 4 6 kg 5 2 kg 88kg 12 3 kg 12 7 kg i 5 15P 5 20P 4 5 15R 6 5 15R 8 5 15R Xtreme Power Conversion XPC Corporation 11 S70 SERIES USERS MANUAL V2 paw Model S70 500 S70 700 70 1000 S70 1500 S70 2000 Operating 32 104 F 0 40 C Temperature 0 90 ENVIRONMENT Audible lt 40dB Altitude 11
6. ACT F GMG Power Conversion UNINTERRUPTIBLE POWER SUPPLY UPS S70 Line Interactive Low Voltage Tower Models USER amp INSTALLATION MANUAL www xpcc com 2012 Xtreme Power Conversion Corporation All rights reserved S70 SERIES USERS MANUAL V2 Package Contents You should be receiving the following items inside the package e UPS Unit e User Manual e Local Monitoring Software CD e USB cable Product Introduction Thank you for selecting this uninterruptible power supply UPS It provides you with protection for connected equipment Please read this manual before installing the S70 Series UPS models S70 500 S70 700 S70 1000 S70 1500 and S70 2000 as it provides important information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Product Overview Many different kinds of sensitive electrical equipment can be protected by an Uninterruptible Power Supply UPS including computers workstations process control systems telecommunications systems sales terminals ot
7. NCERNING THE WARRANTY FOR YOUR XPC PRODUCT THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY Definitions 1 Product means an XPC Standard EPC 120 208 or 240 Volt power protection device that is used in the United States and Canada This policy does not include custom manufactured products 2 Power Disturbance means an AC power line transient telephone line local Area Network or CATV transients if applicable spike or surge 3 Fair Market Value of damaged Connected Equipment as determined by XPC shall be the lower of a the average price the same or similar items are being sold for on eBay b the price list of Orion Blue Book or if such price list is no longer published a published or announced price list reasonably selected by XPC c the lowest price the same or similar items can be purchased for in the United States or d the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or from other sources or persons for the damaged Connected Equipment 4 Initial Purchaser Purchaser or You means the person or entity that originally purchased the Product from an authorized reseller or distributor of XPC Products The Initial Purchaser of this Product is protected for the term of the XPC Limited Warranty against certain losses caused by a Power Dis
8. d e When AC input varies outside the acceptable specification the AVR switches taps on the transformer to better regulate the output e If AC input power fails the inverter turns on an supplies power from the batteries to the load Xtreme Power Conversion XPC Corporation 3 S70 SERIES USERS MANUAL V2 e When AC input power returns the UPS automatically begins supplying the load with power through the AVR circuit e The charger circuit provides recharge for the batteries fj N f A LCD PANEL ON OFF POWER SWITCH S70 SERIES FRONT VIEW AC Mode Indicator Input Voltage gg dx 88a Output Voltage OUTPUT INPUT LAC MODE Battery Level Indicator 4 B B ER Q 1 e Load Level Indicator di flashing indicates flashing indicates low battery level overload condition S70 LCD FRONT PANEL Xtreme Power Conversion XPC Corporation S70 SERIES USERS MANUAL V2 m USB il B COMMUNICATIONS 5 15P INPUT eu i 7 n PORT POWER CORD Nr H 5 4 5 15R OUTPUT RECEPTICLES S70 500 700 REAR VIEW USB COMMUNICATIONS PORT 5 15P INPUT POWER CORD RJ 11 45 SURGE CIRCUIT BREAKER PROTECTION 6 5 15R OUTPUT RECEPTICLES 70 1000 REAR VIEW Xtreme Power Conversion XPC Corporation 5 S70 SERIES USERS MANUAL V2 TT TF ims al USB 5 15P or 5 20P a T COMMUNICATIONS INPUT POWER e Rez PORT CORD RJ 11 45
9. ed through the Product and i exhausts the protection capacity of the Product or ii damages the Product 6 The Load Protection Policy does not apply if the Product has been operated in a failure mode or not in compliance with XPC operating instructions in the Product user s manual or if the Connected Equipment has not been operated in compliance with the instructions and manuals of its manufacturer vendor 7 This policy is null and void if XPC determines in its sole discretion that the Product has been tampered with or altered in any way What is Not Covered Under the Load Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for damage due to telephone line Local Area Network or CATV transients which is covered only if the Product offers such protection 3 DAMAGE CAUSED BY FAILURE TO PROVIDE A SUITABLE INSTALLATION ENVIRONMENT FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO LACK OF A PROPER SAFETY GROUND 4 Damage caused by the use of the Product for purposes other than those for which it was designed 5 Damage caused by accidents or natural disasters including but not limited to fire flood and wind 6 Damage caused by abuse misuse alteration modification or negligence 7 Any labor costs or travel room and board expenses associated with the repair and or restoration o
10. f lost or damaged hardware software or data EXCEPT AS EXPRESSLY PROVIDED IN THIS POLICY XPC SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR MULTIPLE DAMAGES ARISING OUT OF THE USE OF THE PRODUCT OR DAMAGE TO THE CONNECTED EQUIPMENT REGARDLESS OF THE LEGAL THEORY ON WHICH SUCH CLAIM IS BASED EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF SAVINGS OR REVENUE LOSS OF USE OF THE PRODUCT OR THE CONNECTED EQUIPMENT OR ANY ASSOCIATED EQUIPMENT LOSS OF SOFTWARE COST OF CAPITAL COST OF ANY SUBSTITUTE EQUIPMENT FACILITIES OR SERVICES DOWNTIME Xtreme Power Conversion XPC Corporation 16 S70 SERIES USERS MANUAL V2 THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY Submitting a Load Protection Policy Claim 1 Any claim under the Load Protection Policy must be made within 10 days of the date of alleged damage to the Connected Equipment 2 Call the XPC technical support department at 1 800 582 4524 and obtain a Load Protection Policy Returned Material Authorization RMA number Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Purchaser and the name of the power utility supplier for the location of the Connected Equipment XPC will forward to you a Load Protection Policy claims form which m
11. he costs of shipping the defective product to XPC Corporation XPC Corporation will pay for ground shipment of the repaired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the customer has requested and received a Return Material Authorization RMA number DOA equipment is defined as equipment that does not properly function according to user documentation when initially received and connected in conjunction with proper procedures as shown in the user documentation or via support provided by XPC Corporation personnel or authorized agents This warranty shall be void if a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or applicati
12. her critical instrumentation etc The purpose of the UPS is to protect these Xtreme Power Conversion XPC Corporation 2 S70 SERIES USERS MANUAL V2 systems from poor quality utility power complete loss of power or other associated problems Electrical interference exists in many forms causing problems in AC power from lightning power company accidents and radio transmission motors air conditioners and vending machines Protection of sensitive electrical equipment is vital to protect against power outages low or high voltage conditions slow voltage fluctuations frequency variations differential and common mode noise transients etc To prevent power line problems from reaching critical systems causing damage to software hardware and equipment malfunctions the UPS maintains constant voltage isolating critical load output and cleaning the utility AC power Line Interactive Technology A line interactive technology UPS provides basic power protection and Automatic Voltage Regulation AVR to the load when AC input power is available When AC input power is unavailable the line interactive UPS will switch to batteries to supply the load with power In the event that the power failure lasts longer than the UPS backup time the UPS will shut down avoiding battery damage When the input AC voltage returns the UPS will automatically return online to recharge the batteries e ACinput flows into and through the AVR to the loa
13. iginal packaging is no longer available as the Technical Support Technician about obtaining a replacement set of packaging material It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material 2 Include a letter with your name address daytime phone number RMA number a copy of your original sales receipt and a brief description of the problem 3 Mark the RMA number on the outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes 4 Return the UPS by insured prepaid carrier to the address provided by the Technician 5 Refer to the Warranty statements in this manual for additional details on what is covered Xtreme Power Conversion XPC Corporation 13 S70 SERIES USERS MANUAL V2 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY Xtreme Power Conversion XPC Corporation warrants Xtreme Power Conversion equipment when properly applied and operated within specified conditions against faulty materials or workmanship excluding batteries for a period of three years for S70 Series products from the date of purchase XPC Corporation warrants internal batteries for a period of three years from the date of purchase For equipment sites within the United States and Canada this warranty covers repair or replacement at the sole discretion of XPC Corporation The customer is responsible for t
14. isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching WARNING Unit intended for installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of electric shock disconnect the UPS from the main supply before installing a computer interface signal cable Reconnect the power cord only after signaling interconnections have been made Xtreme Power Conversion XPC Corporation 8 S70 SERIES USERS MANUAL V2 Servicing of batteries should be performed or supervised by personnel with knowledge of batteries and the required precautions Keep unauthorized personnel away from batteries The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and follow up maintenance of the UPS and batteries 1 A CAUTION The unit has a dangerous amount of voltage If the UPS indicator is on the unit s outlets may have a dangerous amount of
15. on of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances but it is used at the recipient s sole risk EXCEPT AS STATED ABOVE XPC Corporation DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS STATED ABOVE IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT including but not limited to any costs lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes or claims by third parties Purchaser s sole and exclusive remedy for breach of any warranty expressed or implied concerning Xtreme Power Conversion equipment and the only obligation of XPC Corporation under this warranty shall be the repair or replacement of defective equipment components or parts or at XPC Corporations sole discretion refund of the purchase price or substitution of an equivalent replacement product Xtreme Power Conversion XPC Corporation 14 S70 SERIES USERS MANUAL V2 XTREME POWER CONVERSION LOAD PROTECTION POLICY For Standard EPC 120 208 and 240 Volt Products used in the United States and Canada THIS POLICY IS NOT A WARRANTY REFER TO THE XPC CORPORATION INC LIMITED WARRANTY FOR INFORMATION CO
16. s only Connect a single modem phone line into surge protected IN outlet on the back of the UPS unit Connect from OUT outlet to the computer with phone line cable Connect Communication Cable To allow for unattended UPS shutdown start up and status monitoring connect one end of the communication cable to the USB port and the other end to a USB port of a PC With the monitoring software installed you will be able to schedule UPS shutdown start up and to monitor the UPS status through the PC Turn UPS ON OFF To turn the UPS unit on press the Power switch on the front of Xtreme Power Conversion XPC Corporation 7 S70 SERIES USERS MANUAL V2 the UPS To turn the UPS unit off press the Power switch on the front of the unit again Cold Start Function When the UPS is off and there is not input utility power available it is still possible to cold start the UPS unit to power loads Follow the instructions for Turning UPS ON and be aware that you will see and hear the ON BATTERY ALARM IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS CAUTION UPS having Internal Batteries Risk of electrical shock Hazardous live parts inside this unit are energized from the battery supply even when the input AC power is disconnected CAUTION No User serviceable Parts Risk of electrical shock do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Non
17. treme Power Conversion Corporation products services or UPS Selector sizing please visit www xpcc com Xtreme Power Conversion XPC Corporation 18
18. turbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provided below This policy applies only to the original purchaser of the Product If the Product is transferred or sold to another person or entity this policy is void Load Protection Policy Dollar and Period Limits For purchasers that meet the qualifications and conditions set forth in this policy XPC will provide reimbursement cost of repair or fair market value as determined by XPC during the period limits and up to the dollar limits stated as follows Period of Coverage Term of XPC Limited Warrant Term of XPC Limited Warranty Term of XPC Limited Warranty This Load Protection Policy is not deemed first dollar coverage XPC s obligation is reduced by any amounts that the Initial Purchaser is entitled to recover from other sources regarding the Connected Equipment including but not limited to insurance other warranty extended warranty or legal liability regardless of whether or not the Initial Purchaser makes a claim for recovery Eligibility for coverage under the Load Protection Policy 1 The Product must be registered on the XPC website www xtremepowerconversion com within 10 days of purchase All required information must be provided and Purchaser should retain a copy for Purchaser s records When registering on the website Purchaser must list all connected equipment that
19. ust be completed and filed with XPC within 30 days a Mark the Load Protection Policy RMA number on the Product you are returning b Pack the Product in its original packaging or similar packing materials if the original packaging has been discarded Enclose the completed Load Protection Policy claim form and a copy of your original sales receipt for the Product in the box c Mark the RMA number clearly on the outside of the box d Ship the Product one way shipping charges paid by you to XPC Corporation 230 Yuma Street Denver Colorado 80439 Attn LPP RMA 3 XPC will evaluate the Product to determine its level of functionality and will examine the Product for evidence of damage from a Power Disturbance a If XPCs evaluation provides no evidence of damage from a Power Disturbance XPC will send to the Purchaser i a report summarizing the tests performed and ii a rejection of claim notice b If the Product shows evidence of damage from a Power Disturbance XPC will request that all Connected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to you for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above
20. voltage even when not plugged into the wall outlet because the battery may continue to supply power Care should be taken to undertake installation indoors free from electrically conductive particles which are under temperature and humidity control in order to reduce the risk of electric shock It is best to disconnect the device using the power supply cord Ensure that the equipment is placed in a position near the outlet where easily accessible All servicing on this equipment must be carried out by qualified service personnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected Xtreme Power Conversion XPC Corporation 9 S70 SERIES USERS MANUAL V2 Troubleshooting Charge the UPS at least 6 Low battery Ee ane No words display on front panel The UPS is not turned on Alarm continuously sounds when the AC input is normal The UPS is overloaded The UPS is overloaded When power fails backup time is shorter than expected Battery defect possibly due to high environmental temperature or improper operation of the battery Utility power is available but the UPS is in battery mode Power cord is loose Battery voltage is too low Replace the battery with Battery fault the same type of battery Press the Power Switch on the front of the UPS Remove some of the load from the output of the UPS Remove some of