1. 2 2 2 8 J e 5 Z2 n OO 8a 1 7 Aux suppl S a Sjj pply Aa 5 ok Ne Control Power 6 oO 6 ola 44 to 277 VAC IDC gt 2 E S2 a YE LOAD lA RS 485 SG Communication PM1200 Connection representation only Other types of connection are possible Refer to the PM1000 series Quick Start Guide for details L1 LINE PT if VAC LL 2481 V VER 03 04 00 80 to 480 Vac LL Ook O M S gt 50mA to 6A S N COYYWWDXXXX Control Power a t Aux supply 44 to 277 VAC DC a I Option List RS 485 THD DM IE 44 to 277 Vaclde Spay Ww ep D oo on l Communication PM1200 Connection representation only Other types of connection are possible Refer to the PM1000 series Quick Start Guide for details Schneider Electric USA Inc 295 Tech Park LaVergne TN 37086 Tel 866 466 7627 Toll Free www PowerLogic com Doc 3000HO1005 Schneider Electric PowerLogic Square D and Modbus are trademarks or registered trademarks of Schneider Electric and or its affiliates in the United States and or other countries Other marks used herein may be the property of their respective owners SS This document has been printed on recycled paper March 2010 2010 Schneider Electric All rights reserved
2. 62053 23 Class 2 1 0 of reading Additional error of 0 05 of full scale for meter input current below 100 mA Data update rate Input voltage Inputs characteristics Measured voltage Permissible overload Burden 1 sec V1 V2 V3 Vn 80 480 V AC L L without PTs Up to 999 kV with external PTs 1 10 Un 480 V L L 0 2 VA per phase max Impedance Frequency range VLL 4 Mohms VLN 2 Mohms 45 65 Hz 1A 99 0kA Input current CT ratings Primary characteristics Secondary Measurement range Permissible overload 1A 5A 50 mA 6 A 5 mA is the starting 10 A continuous Burden Impedance Power supply AC 0 2 VA per phase max lt 0 1 ohm 44 277 V AC at 50 Hz 60 Hz DC Ride through time Burden Mechanical characteristics Weight 44 277VDC 100 ms at 50V 3 VA max 18 oz shipping 1 oz unpacked IP degree of protection Front IP 51 Back IP 40 Dimensions Environmental conditions Operating temperature Bezel 96 x 96 mm Depth 80 mm behind bezel Panel cutout 92 x 92 mm 14 F to 140 F Storage temperature 13 F to 158 F Humidity rating 5 to 95 RH non condensing Altitude 6500 ft Measurement CAT III Pollution degree 2 Protection class 2 Electromagnetic compatibility Electrostatic discharge IEC 61000 4 2 Immunity to electromagnetic RF fields IEC 61000 4 3 Immunity to electrical fast transients IEC 61000 4 4 Immunity to surge waves IEC 61000 4 5
3. Conducted disturbance immunity IEC 61000 4 6 Damped oscillatory waves immunity Impulse voltage withstand Conducted and radiated emissions Safety and standards Safety construction CE certification IEC 61010 IEC 61000 4 12 6kV for 1 2 50 uS per IEC 60060 1 CISPR11 Class A Self extinguishable VO plastic UL 508 Yes Complies with Regulation EC n 1907 2006 of Dec 18 2006 named REACH related to the Registration Evaluation Authorization and restrictions applicable to Chemical substances Communication RS 485 port Display characteristics Integrated LED display 2 terminals only Baud rate up to 19 200 bps Protocols Modbus RTU View 3 parameters together on 3 line 4 digit per line display Auto scaling capability for Kilo Mega and Giga values User selectable default display page Password protection for setup parameters Analog load bar Color coded analog indicator provides an option to select the full scale of the load bar based on the sanctioned power limit PM1000 series and DM6000 series Functions and characteristics cont Use on LV and HV systems e Current and voltage accuracy 1 0 Power accuracy Energy accuracy 1 0 Number of samples per cycle 20 at 50 Hz 20 at 50 Hz Current Per phase amp Neutral Voltage Average Phase to Neutral amp Phase to Phase Frequency Active apparent power Total amp per phase Power factor Average amp per phase e Unbalance C
4. PowerLogic PM1000 series power meter and DM6000 series digital panel meter Technical data sheet Schneider ma l i rA PowerLog priyo Schnpider PM1000 series power meter Functions and characteristics The PowerLogic PM1000 series power meters are easy to use cost effective meters that offer the basic measurement capabilities required to monitor an electrical installation Characterized by their rugged construction compact size and low installation costs these state of the art multi function meters are ideal for control panels motor control centers and genset panels Applications Power monitoring operations Load studies and circuit optimization Equipment monitoring Meter s outputs can be used by control devices Preventative maintenance PowerLogic PM1000 power meter front display above and rear below Main characteristics Accurate metering The meter conforms to accuracy class 1 0 as per IEC 62052 11 and IEC 62053 21 Easy to read display The bright alohanumeric 15mm high LED display provides three lines for measurement values with four digits per line The display auto scales for Kilo Mega and Giga values Auto scrolling mode allows for easy reading i a Lf an GLT E iE M a Sea Analog load bar The color coded analog load bar indicates the percentage of load through 12 LED segments AEE a etd e i PI e i a en Turbo Key access to inform
5. ation The Turbo Key button lets you access the most commonly viewed parameters or enter setup mode with a single push of the button Quick and easy installation Setup is done through the front panel keys Quick entry to setup during power up by TURBO key Direct connection for metering voltage inputs up to 480 Vac L L Color keyed terminal board labeling The color keyed label on the terminal board helps ensure accurate wiring Secure settings Safeguard access to setup parameters with unique password protection A keypad lock lets you display a user selected page by default Part number PM1200 power meter with basic readings energy and demand parameters and summary screens with an RS485 communication port METSEPM1200 DM6000 series digital panel meter Functions and characteristics The PowerLogic DM6000 series digital panel meters offer the basic measurement capabilities required to monitor an electrical installation Characterized by their rugged construction compact size and low installation costs these state of the art meters are ideal for control panels motor control centers and genset panels i Applications schneider a e m Power monitoring operations E d m Equipment monitoring m Preventive maintenance Prga pike DM6000 series digital panel meter front display R above and rear below Main characteristics Easy to read display The bright alohanumeric 15mm high LED display provides three lines fo
6. r measurement values with four digits per line This display auto scales for Kilo Mega and Giga values Auto scrolling mode allows for easy reading Analog load bar The color coded analog load bar indicates the percentage of load through 12 LED segments Pit Ee i 7 Turbo Key access to information The Turbo Key gives access to the most commonly viewed parameters or enter setup mode with a single push of the button Quick and easy installation Setup is done through the front panel keys Quick entry to setup during power up by TURBO key Direct connection for metering voltage inputs up to 480 Vac L L Color keyed terminal board labeling The color keyed label on the terminal board helps ensure accurate wiring Secure settings Safeguard access to setup parameters with unique password protection A keypad lock lets you display a user selected page by default Part number DM6200 digital meter with basic readings plus an R8485 communication port METSEDM6200 PM1000 series and DM6000 series Functions and characteristics cont Electrical characteristics Type of measurement Measurement Current and voltage PM1200 DM6200 True RMS up to the 15th harmonic 20 samples per cycle at 50 Hz 1 0 of reading accuracy Power Active 1 0 of reading 2 0 ofreading 1 0 of reading 0 1 of reading 1 0 of reading IEC 62053 21 Class 1 Apparent Frequency Power factor Energy Active Reactive IEC
7. urrent voltage Phase angle Between V amp l Pht Ph2 Ph3 e RPM For generator only soeed calculated on generator voltage output and number of machine poles Active reactive apparent energy Current Present amp max Active apparent power Present amp max Active apparent power settable by user Client can select one parameter only A KW or KVA Total harmonic distortion Current voltage per phase Run hours Operating time for load in hours ON hours Operating time for meter in hours e INTR Number of interruptions LED display RS 485 port Modbus protocol 9 mm additional space on both sides of the meter Le inside the panel ann PowerLogic PM1000 series power meter dimensions and DM6000 series digital panel meter dimensions PM1000 series and DM6000 series Installation and connections ata 5026 Use J a t a PT if AC LL gt 481 V a T VER 03 04 00 80 to 480 Vac LL T w N 2 3 lt Q QOQ S2 B 53 z o Z 9 gjet 5 Ss g a Aux supply G2 E Ra Control Power S 5 2 J 44 to 277 VAC DC an YE RS 485 a Communication PM1200 Connection reoresentation only Other types of connection are possible Refer to the PM1000 series Quick Start Guide for details PM1000 series and DM6000 series Installation and connections cont LINE ia Ae S2 m gt S F O O 3 lt Ww E if QO