1.      li    3 risers  included       measurements  they should choose a site where  the stream is not split by rocks  partially submerged obstructions  or sand bars   The impeller of the flow rate sensor should always be pointing into the flow when  measurements are being made  Students need to stand on the shore when taking  measurements close to the shore  or stand as far downstream as possible from the  sensor when placing the sensor in deeper water    Because stream flow is easily affected by weather conditions  it is important that  good notes concerning date  time  and weather be taken whenever flow  measurements are made        Warranty   Vernier warrants this product to be free from defects in materials and workmanship  for a period of five years from the date of shipment to the customer  This warranty  does not cover damage to the product caused by abuse or improper use        Measure  Analyze  Learn   Vernier Software  amp  Technology  13979 S W  Millikan Way e Beaverton  OR 97005 2886  Toll Free  888  837 6437 e  503  277 2299 e FAX  503  277 2440  info vernier com e www vernier com    Rev  6 5 2012   Logger Pro  Logger Lite  Vernier LabQuest 2  Vernier LabQuest  Vernier LabQuest Mini  Vernier LabPro  Go  Link   Vernier EasyLink and other marks shown are our trademarks or registered trademarks in the United States    TI Nspire  CBL 2  TI GRAPH LINK  and TI Connect are trademarks of Texas Instruments    All other marks not owned by us that appear herein are the prope
2.    Lab Cradle  EasyLink  or CBL 2     the data collection software identifies the sensor  and uses pre defined parameters to configure an experiment appropriate to the  recognized sensor        How the Flow Rate Sensor Works    The Vernier Flow Rate Sensor measures the velocity of flowing water  When placed  in a stream  as shown here  water flows against the blades of the impeller  causing it  to turn  The faster the water flows  the faster the impeller turns  A bar magnet  rotating with the impeller triggers a reed switch with each half rotation  The switch  sends a pulse to the signal conditioning box  where the pulses are converted into a  voltage that is proportional to flow rate  Flow rate can be measured in m s or ft s         reed switch        bar magnet    impeller    Front Back    Calibration Information   We feel that you should not have to perform a new calibration when using the Flow  Rate Sensor in the classroom  We have set the sensor to match our stored calibration  before shipping it  You can simply use the appropriate calibration file that is stored  in your data collection program     Uses of the Flow Rate Sensor    Calculating Discharge  To determine the amount of water flowing in a stream  you need to measure the rate  at which the water flows and the area the water occupies at a specific point in the  stream  The discharge  or stream flow  is the flow rate multiplied by the area of  water    Flow Rate x Area of Cross Section   Discharge or Stream Flow  
3.  chances of dropping the equipment into the water and  damaging it    4  Always follow safety precautions when entering the stream  If the water is too  deep or swift  select another site  Never venture out into the stream alone without  another person available to assist you in case of emergency     Testing Procedure    Measuring a Stream Cross Section   1  Using the measuring tape  determine the width of the stream cross section in  meters and record the measurement on a data sheet  Divide the cross section into  six equally spaced sections                       1 2 3 4 5 6 7  l l l l l l l       t    t  l l l l l  Initial   Final    distance   0 distance   Stream width  Initial Final  depth  0 depth   0                2  Using the meter stick  measure the depth of the stream in  meters at each of the equally spaced points along the cross  section  Record the depth and the distance out from one  shore edge  in meters  on a data sheet  Always measure  from the same shore  Be sure to include both the initial  distance and depth and the final distance and depth           distance out             Measuring Flow Velocity  3  Connect the Flow Rate Sensor to the interface and start the data collection  program   4  Collect stream flow data   a  Use the Stream Flow experiment file in Logger Pro or set up the program for  single point data collection   b  Submerge the impeller of the Flow Rate Sensor to about  40  of the depth measured at each section  If the l  section is shallow e
4.  deep or swift  Water with a flow velocity of 0 5 m s or greater  is considered to be swift  Water with a depth greater than the top of your knee  should be considered deep    Never work alone around a stream  Students should always work with others in  groups of 2 3  Do not allow students to wander away from their group  It is  important to know where student groups are at all times  Students should not  change locations without notifying their instructor first       Before using a particular site  it is best to survey the area for unseen dangers     such as unstable banks  dangerous obstacles in the stream  or fallen trees  Avoid  these possible dangers    Always be careful when crossing a stream  If it looks dangerous  select another  spot in the stream to cross       Students should wear warm  waterproof clothes when working in a stream  If    possible  they should bring spare items such as dry socks that can be worn after  working in the water  Prolonged exposure to cold waters can result in  hypothermia  which can be a life threatening condition     Additional Tips    l       When students are selecting sites to take flow    The plastic risers that come with the Flow Rate  Sensor can be very helpful in keeping the sensor at  the same orientation while taking measurements   When using the risers  simply place the bottom of  the sensor rod against the stream bottom  If you are  unsure which riser to use  start with the medium  riser first and gauge the depth from there   
5. Detailed instructions on collecting flow rate data and calculating discharge can be  found in the next section of this booklet        Sediment Transport    The amount of sediment and  maximum particle size that can be    W       transported by moving water is z   related to the flow velocity  SE as n   Therefore  flow velocity data a   obtained using the Flow Rate Sensor 0 01   can be used to determine what size   particles will stay in motion at a ii  ry me ee am ce  particular flow velocity  This chart  Clay Silt Aard     Bodas    derived from accumulated observed  data  shows that for a given flow  velocity there is a range of behavioral possibilities for sediment particles lying on the  bed  or entrained within the flow  of a stream  At a measured flow velocity of 1 m s   silt and sand  though not compacted clay  will be eroded from the stream bed and  transported downstream  At the same velocity  all sediment particles between 10 mm  and 100 mm that were already in motion will continue in motion  Particles greater  than 100 mm will be deposited  A Flow Rate Sensor can be a valuable observational  tool when used in sediment transportation studies        Describing Flows    Using the Flow Rate Sensor  it is  possible to map flow characteristics of  a stream by taking measurements at  different spots and depths  To  understand the flow characteristics  within streams of moving water  it 1s  helpful to construct Stream Lines and  Vector Lines  The illustration shown  here sh
6. Flow Rate Sensor   Order Code FLO BTA     The Flow Rate Sensor measures the velocity of  water in a river  stream  or canal  It can be used to  study the discharge  flow patterns  and sediment  transport of a stream or river     Inventory of Items Included with the  Flow Rate Sensor    Check to be sure that each of these items is  included in your Flow Rate Sensor package     e Flow Rate Sensor  impeller rod with 5 meter  cable     e Three riser rods  short  medium  and long        Collecting Data with the Flow Rate Sensor  This sensor can be used with the following interfaces to collect data     e Vernier LabQuest   2 or original LabQuest as a standalone device or with a  computer    e Vernier LabQuest   Mini with a computer   e Vernier LabPro   with a computer or TI graphing calculator  e Vernier Go     Link   e Vernier EasyLink     e Vernier SensorDAQ    e CBL 2      e TI Nspire    Lab Cradle    Here is the general procedure to follow when using the Flow Rate Sensor     Connect the Flow Rate Sensor to the interface       Start the data collection software          The software will identify the Flow Rate Sensor and load a default data collection  setup  You are now ready to collect data        Data Collection Software  This sensor can be used with an interface and the following data collection software     e Logger Pro 3 This computer program is used with LabQuest 2  LabQuest   LabQuest Mini  LabPro  or Go  Link     e Logger Pro 2 This computer program is used with ULI or 
7. Serial Box Interface     e Logger Lite This computer program is used with LabQuest 2  LabQuest   LabQuest Mini  LabPro  or Go  Link        If you are using Logger Pro 2 with either a ULI or SBI  the sensor will not auto ID   Open an experiment file for the Flow Rate Sensor in the Probes  amp  Sensors folder     e LabQuest App This program is used when LabQuest 2 or LabQuest is used as a  standalone device    e EasyData App This calculator application for the TI 83 Plus and TI 84 Plus can  be used with CBL 2     LabPro  and Vernier EasyLink  We recommend version  2 0 or newer  which can be downloaded from the Vernier web site   www vernier com easy easydata html  and then transferred to the calculator  See  the Vernier web site  www vernier com calc software index html for more  information on the App and Program Transfer Guidebook    e DataMate program Use DataMate with LabPro or CBL 2    and TI 73  TI 83   TI 84  TI 86  TI 89  and Voyage 200 calculators  See the LabPro and CBL 2     Guidebooks for instructions on transferring DataMate to the calculator    e DataQuest    Software for TI Nspire    This calculator application for the  TI Nspire can be used with the EasyLink or TI Nspire Lab Cradle    e LabVIEW National Instruments LabVIEW    software is a graphical  programming language sold by National Instruments  It is used with SensorDAQ  and can be used with a number of other Vernier interfaces  See  www vernier com labview for more information     NOTE  Vernier products a
8. nough  use the plastic risers that are  included with the flow rate sensor to support the sensor  on the stream bed  The risers make it easier to keep the  impeller of the sensor in the same spot and oriented in  the same direction                       c  Point the impeller of the sensor upstream  as shown  below  and directly into the flow  Select START or  to begin sampling  Hold the sensor in place for  10 seconds while data are being collected  Once data  collection is finished  the flow rate will be displayed     Record the reading on the Data  amp  Calculations sheet   Repeat for each of the remaining sections           Calculating Stream Flow   5  Create a graph of stream depth vs  distance from the shore    6  Integrate the data  The integral value will give you the cross sectional area of the  stream     Determining Discharge   7  Calculate the average velocity for each site    8  To calculate the discharge or stream flow  multiply the average stream velocity  by the cross sectional area  Repeat for Site 2  To convert from m  s to cubic feet  per second  multiply by 35 315     Detailed instructions for data collection with computers  LabQuest  TI graphing  calculators  and Palm Powered handhelds may be found in our Water Quality with  Vernier lab book  The Stream Flow test is test number 16 in this book     Additional Information for Instructors  Safety Tips    l     Follow safety guidelines when students are working in or near water  Avoid sites  where the water is
9. ows how Stream Lines depict  possible paths of a single fluid  particle        Vector Lines represent both the flow rate  and direction  The longer and broader the  line  the greater the flow velocity  Vector  Lines convey useful information about the  stream flow characteristics     Shean Flow  Sample Activity     Site Selection   1  Select two sites within a 50 m stretch of the stream  that are as far apart as possible and are  representative of the stream as a whole  Avoid sites  with bends or breaks in the stream caused by rocks or  sandbars  Try to choose a site where some flow can  be observed  One site can have a swift flow similar to  that found in a riffle  The second site can have a  moderate or slow flow like that found after a pool  It  is not necessary for both sites to be the same    2  At each site  you are going to take a cross section of  the stream and measure its width and depth  Try to  select a cross section that is shallow enough to  measure depth with a meter stick and easy to cross   To measure stream flow using the Flow Rate Sensor   avoid sites where the stream depth 1s less than 10 cm    3  The Flow Rate Sensor is equipped with a 5 m cable   This enables you to take measurements up to 4 m  away from the shore without carrying the interface  out into the stream    If the stream 1s wider than 4 m  monitor the stream flow out from one shore line   then have the person holding the interface switch to the other side of the stream   This should reduce the
10. re designed for educational use  Our products are not  designed nor recommended for any industrial  medical  or commercial process such    as life support  patient diagnosis  control of a manufacturing process  or industrial  testing of any kind        Storage and Maintenance of the Flow Rate Sensor   When you have finished using the Flow Rate Sensor  simply rinse it with clean water  and dry it using a paper towel or cloth  The probe can then be folded up and stored   To prolong the life of your Flow Rate Sensor  we recommend that the moving parts  of the impeller rod be lubricated with WD 40    or a similar lubricant  after every   few field uses    When using the impeller rod  avoid hitting the impeller blade on rocks and other hard  surfaces  If the impeller blade is bent  it will decrease the accuracy of the sensor     Specifications  Range  0 to 4 0 m s  0 to 13 ft s   13 bit resolution  SensorDAQ   0 0006 m s  12 bit resolution  LabPro  LabQuest 2    LabQuest  LabQuest Mini     Go Link  and TI Nspire    Lab eee  Cradle    10 bit resolution  CBL 2      0 005 m s  Accuracy   1  of full scale reading    Response time     Temperature range  can be placed in    Stored Calibration Values    slope   intercept     98  of full scale reading in 5 seconds   100  of full scale in 15 seconds     0 to 70  C    1 m s V  0 m s    This sensor is equipped with circuitry that supports auto ID  When used with  LabQuest 2  LabQuest  LabQuest Mini  LabPro  Go  Link  SensorDAQ  TI Nspire    