1. Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE PREDATOR DWS POE w DWS BPA T BYPASS PREDATOR WHOLE BUILDING UV WATER DISINFECTOR INSTALLATION GUIDE amp USER S MANUAL Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE Your O SO PURE Disinfection System is actually two systems in one The first stage filter utilizes a revolutionary NEW dual micron Polypropylene spun cotton sediment filter This filter is designed to reduce sand silt and rust while greatly extending the life of the second filter micron carbon block The outer portion of this filter is a 50 micron while the inner rap is rated at 5 microns the second stage filter reduces organics pesticides chlorine chloramines debris and cleanses the water while reducing cysts and protozoa such as cryptosporidium and giardia lamblia organisms With the self cleaning system the water flows through the sumps around the filters and out via the ball valves located at the bottom of the filter sumps The daily flush cycle will automatically wash away sediment and debris which can shorten the life of the filters BEFORE YOU BEGIN The main components to identify include The DWS POE Predator with the following components in its box e Quartz sleeve and UV lamp both shipped in separate labeled cardboard tubes e Installation Kit a plastic bag containing parts amp instructions required for
2. a professional plumber install this system Please READ ALL DIRECTIONS THOROUGHLY AND REVIEW ALL PHOTOS BEFORE INSTALLING This system is designed to filter a large volume of water for approximately one year between filter cartridge changes The DWS POE should be mounted near the entry of the water main inside of the building or near a drain in a NO FREEZE area If mounted outside in an ENCLOSED BOX be sure that the temperature will not reach freezing or below Allow sufficient space below the unit approx 24 so that the filter sumps can be screwed on and off easily It s important to ensure that there is at least 19 of clearance above the UV chamber for annual replacement of the UV bulb MOUNT THE DWS POE First find the mounting template inside of the Install Documentation folder and choose the location for wall mounting the DWS POE unit Mark and drill the three mounting holes NOTE For ease during mounting you can reduce the weight of the system by removing the sumps and filters prior to installing the mounting bracket DO NOT INSTALL QUARTZ SLEEVE UNTIL UNIT HAS BEEN MOUNTED TO WALL Once unit has been mounted reinstall filters and filter sumps onto unit INSTALLING COPPER BYPASS SUBASSEMBLY amp TRANSFORMER BOX if this option was ordered Locate the copper bypass subassembly with solenoid AE the copper attached and the copper cane cane to the POE s Install the copper cane to the POE s OUTPUT i e right T O
3. is possible that the flush times may need to be increased to a maximum of FOUR 4 flushes per day instead of preset three 3 flushes Check the small 50 micron screen filter on the bottom of the first sump if plugged with dirt unscrew the clear lid and clean out the metal screen then check the filter inside the first sump If filters are plugged call to order replacement filters Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE Super Speedfit Fittings Make Secure Connections Simple O S O PU F E In all applications JG Super Speedfit fittings Require NO tools Tubing is simply inserted into The fitting collet to effect a secure connection Whether metal or plastic tubing is used the Integrity of the connection is assured INSTRUCTIONS FOR INSTALLATION OF JOHN GUEST FITTINGS SECURE CONNECTIONS ARE SIMPLE a CUT THE TUBE SQUARE AND PUSH PAST THE O RING TO THE TUBE STOP KERJ LOCKING CLIP Ls nA TUBE IS SECURED IN POSITION PLACED HERE DISCONNECTION IS JUST AS EASY Se LOCKING CLIP PUSH COLLET AGAINST BODY N SEE INSET SLIDE TUBE OUT OF FITTING Pa Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE O SO PURE 1 YEAR LIMITED WARRANTY For the following systems DWS 008 DWS DDI DWS POE DWS SADI DWS HERO O SO PURE warrants this device to be free from defects in workmanship
4. RY WARNING DO NOT DAMAGE BATTERY RISK OF FIRE EXPLOSION OR ELECTRIC SHOCK REPLACE BATTERY WITH O SO PURE SUPPLIED SERVICE PARTS ONLY DISPOSE OF USED BATTERY PROPERLY TIMER TIMER SOLENOID VALVE TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE SOLUTION valve s not operating debris in valve s clean valve s timer LCD screen not lit dead AA battery replace AA battery flashing battery symbol low AA battery replace AA battery Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE amp RE DWS POE TROUBLE SHOOTING INSTRUCTIONS IF THE UV LAMP FAILS TO ILLUMINATE Check to see when the original or replacement lamp was purchased Turn off ALL electrical power to the system by unplugging the power cord Remove the UV control module using a Phillips screwdriver Slide the old lamp out from the TOP and unplug from the UV lamp power cord HOLD THE UV LAMP ONLY BY THE CERAMIC ENDS AND USE THE COTTON GLOVES Carefully discard the old lamp Take the new UV lamp using the cotton gloves and hold on to the ceramic ends plug it into the lamp power cord Slide the new UV lamp into the filter housing and reattach the UV control module Restore the electrical power if the UV lamp fails to illuminate call O SO PURE Check for any possible leaks IF THERE IS A WATER LEAK Shut off the water supply to the unit and unplug the power cord Check the status of the filter sumps inspect both the
5. UTPUThere hand SIDE as shown in photo at right Next install the copper bypass subassembly to the POE s INPUT i e left hand SIDE and to the OUTPUT of the cane as shown in photo below Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE Next locate the 24V Gray Transformer Box and remove the two screws that hold the front cover see images below and at right Unscrew the 3 machine screws on the POE s front bracket and mount the Transformer Box as shown in the image at right Close the front cover and reinstall the two screws that secure it Connect the two leads from the gray cable with red female push on lugs to the two wires with male push on lugs from the black 24VAC solenoid Below is the wiring diagram from the 24V transformer box for remote on off control of the main water shutoff valve Please note that this wiring is to be supplied by the customer on site aa Y ae i poset Gd 00 z SECM ae is The Ultavioh iy 800 676 4 F O SO PUI FILTER 2 20 CARBON FILTE TO ACCESS INSIDE REMOVE THESE SCREWS NOTE THAT THIS WIRING IS TO BE SUPPLIED BY CUSTOMER ON SITE FOR REMOTE ON OFF CONTROL OF THE MAIN WATER INDICATING i SHUTOFF VALVE LAMP MAIN VALVE ON OFF SWITCH POWER CORD TO MAIN WATER SOLENOID VALVE Manual G Should the power ever go out and you wish to stop water flow to Override unit there is a small white manual override switch
6. ace at its election the unit FREE OF CHARGE on receipt of the unit charges pre paid if mailed or shipped with proof of date of purchase satisfactory to O SO PURE at the following address O SO PURE 2323 W Mescal St Suite 204 Phoenix AZ 85029 IMPORTANT It is recommended that you replace all filters once a year and the UV lamp once a year if applicable to insure proper treatment of drinking water O SO PURE will not guarantee a kill rate above 80 without properly maintaining your filters and UV lamp Failure to change UV lamp and filters WILL void the manufacturer warranty or if filters or UV lamps are purchased from another source other than O SO PURE ANY and ALL CLAIMS WILL NOT BE BACKED BY THE MANUFACTURER Should the UV Water System fail due to use of incorrect filtration or UV lamp O SO PURE WILL NOT BE HELD RESPONSIBLE OR HELD LIABLE DATE OF PURCHASE SERIAL NUMBER Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE this page intentionally left blank Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE Certificate of Referral Please let your professional network know how this system assists in your practice Give them a copy of this page and they will receive a 50 rebate on the purchase of an eligible O SO Pure system We ll send you a 25 referral fee when they purchase using this certificate This certificate entitles the holder
7. and material under normal usage and service from date of purchase as follows All components are warranted for a period of 1 year with the following exceptions e Filters UV lamp This Warranty excludes damages that in the opinion of O SO PURE have been caused by improper installation alteration misuse accident or negligence Repairs must be performed by an O SO PURE authorized agent with parts obtained from O SO PURE O SO PURE will not warrant component parts supplied by manufacturers who provide separate warranties for their merchandise However O SO PURE will contact the representative manufacturer on your behalf O SO PURE reserves the right to make revisions to the design or manufacturing of this model without obligation to owners of this product O SO PURE will not be liable to perform its obligations under this Warranty if such obligations result from 1 Improper installation or unauthorized alteration 2 Misuse or negligence 3 Accident or excessive wear 4 Damage or use with any products not intended for its use 5 Exposure to the elements including direct sunlight excessive heat freezing temperatures humidity or rainfall 6 Are the result of but not limited to acts of God labor disputes transportation strikes or any conditions beyond control of O SO PURE lf a defect in material or workmanship is discovered within the warranty period O SO PURE s sole obligation will be to repair or repl
8. cess to UV Lamp Remove UV Control Module from the system s mounting bracket by removing 4 mounting screws 6 Remove UV lamp from system being careful not to break UV lamp or dislodge quartz sleeve Remove UV control module with UV lamp by lifting the control module straight up from mounting bracket The four pin socket is attached to the UV control module by a short cable that allows for correct insertion depth Grasp UV lamp and four pin socket firmly and separate lamp from connector NOTE The inside of the quartz sleeve must be completely dry before installing the replacement UV lamp Hold replacement UV lamp by the ceramic ends only Do not touch the glass Clean glass with isopropyl alcohol if necessary 7 Install the replacement UV lamp by reversing steps 5 and 6 of this procedure Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE INSTRUCTIONS FOR SETTING THE ORBIT TIMER NOTE THE TIME ZONE IS PRE SET TO THE UNIT S DESTINATION BEFORE THE DWS POE UNIT LEAVES THE FACTORY THE THREE DAILY DEFAULT FACTORY PRESET FLUSH TIMES ARE 9 AM 12 PM AND 4PM MONDAY FRIDAY TO SET START TIMERS FOR PROGRAM A Turn rotary dial to A CYCLES START TIMES The curser will blink at start time 1 on the display Press the Plus or Negative key to advance to desired start time Press ENTER cursor advances to Start time 2 f more than one start time is required repeat step B f
9. ck cash gift card Disbursements will be distributed quarterly after receipt of payment from the dealer o Should the purchaser return the water system for a refund O SO Pure reserves the right to deduct the referral fee from future disbursements O Disclaimer O SO Pure reserves the right to modify or discontinue this program upon notification to registered referring parties Such notification will occur via referring party s email address Referring party shall keep O SO Pure informed of registration information changes at support osopure com Be sure to include the unique serial on this page Referring party is responsible for monitoring email address on file including SPAM filter settings
10. e at right Ensure that tubing is cut smoothly amp evenly when done re insert the red clip onto the coupling Each filter sump both filters amp UV is equipped with a shut off valve This valve is provided to allow the filter sumps to be drained of water before removal greatly simplifying the filter replacement and quartz sleeve cleaning procedures See above image at left for the default settings NOTE During normal operation the drain valves on filter sumps 1 and 2 MUST be turned to the ON position to allow for the automatic daily filter flush cycles to occur SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS CLEANING The inside of the DWS POE system and its quartz sleeve should be cleaned each time the filters are changed Clean all parts except the filters and electronic parts with soap and rinse them thoroughly with clean potable water Dry the inside of the quartz sleeve thoroughly before re assembling system NOTE The presence of iron or general poor water quality will require frequent inspection and cleaning O RINGS Lubricate each O ring with a silicone based O ring lubricant to ensure a proper seal FILTER REPLACEMENT Filters will normally last approximately 8 months to a year Filter life will vary depending upon your local water conditions A reduced flow rate or deteriorating water quality indicates that the filters must be changed UV LAMP REPLACEMENT UV lamps MUST be changed every 12 months While UV lamps rarel
11. his reduces Fi ge RIL TR pressure inside the system so that the sumps may pee p i be safely removed 5 Oneata time using the supplied 10 length of 3 8 tubing w male quick disconnect elbow on one end drain water from each sump down the drain 6 Using the spanner or sump wrench remove each sump Remove each filter as its sump is removed and discard the old filters NOTE Use sanitary rubber gloves for this procedure to avoid contaminating the cleaning solution or filters Wear gloves whenever cleaning components or handling new filters 7 Clean quartz sleeve carefully using vinegar to remove hardness Do not use abrasive materials Rinse sleeve thoroughly with clean potable water Replace any sleeve that is damaged or will not come completely clean 8 Remove sump O rings and wash with cleaning solution Rinse them well with clean potable water Inspect O rings for damage i e nicks or scratches Replace damaged O rings 9 Clean sumps and heads inside and outside with washcloth and cleaning solution Do not use abrasive materials CAUTION Use care when cleaning UV head Do not get the UV control module or connectors wet 10 Rinse sumps and heads with clean potable water UV CHAMBER DISINFECTION PROCEDURE CAUTION WEAR SAFETY GLASSES AND SANITARY RUBBER GLOVES WHILE PERFORMING THIS PROCEDURE CAUTION EXCESSIVE CONCENTRATIONS OF BLEACH WILL DAMAGE PLASTIC AND RUBBER COMPONENTS Rinse all parts
12. installation e 2 10 foot lengths of 3 8 blue polypro tubing e Copper Bypass w Solenoid subassembly and 24V Transformer Box only if ordered e Copper Cane for Bypass subassembly Your O SO PURE system requires adequate water pressure The unit is designed to operate within a pressure range of 40 PSI to a maximum of 75 PSI CAUTION If the water pressure exceeds 75PSI then a pressure regulator must be used CAUTION Do not install a pump on outlet side of system as damage to the quartz sleeve may occur If pump is required install it on inlet side of system and verify with the system s pressure gauges that it does not exceed 75PSI Higher pressures may damage equipment CAUTION Prevent the UV water system from extreme heat exposure 125F max CAUTION 0 So Pure recommends that only PLASTIC fittings be used for connecting the plumbing line to the inlet outlet ports of the system Use of any metal male fittings inside of plastic female threaded sump heads voids the warranty CAUTION Do not over tighten fittings connected to inlet outlet ports of DWS POE system CAUTION Do not install clear or translucent tubing on the outlet side of system NOTE O SO PURE highly suggests installing a bypass valve of SOME sort on this unit be it an O SO PURE bypass assembly or a 3 party manufacturer s Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE INSTALLATION PROCEDURES We recommend
13. on the bottom side of the black solenoid valve which will open or close the valve manually see image at right EA roo EN oS ee ON E gt gt iy Ss i aly EATI fen fy MM NORAD t 7 Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE INSTALLING QUARTZ SLEEVE CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear protective gloves provided in the POE Installation Kit when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints on either part may reduce the effectiveness of the light Remove far right hand sump from UV sump head Wearing provided gloves remove quartz sleeve from packing tube The plastic white quartz sleeve adapter should already be attached to the quartz sleeve itself and located on the sleeve approx where it needs to be after sleeve is installed Place a small amount of silicone based O ring lubricant on the outside of the open end of the quartz sleeve that will engage the O ring inside UV sump head To avoid breakage make sure that the quartz sleeve goes in straight by pushing it with a slight twisting motion as you insert it You will feel it engage the O ring inside of the UV sump head when it is all the Way in Once installed reattach the UV sump to the sump head Set the elbow ball valve on bottom of UV sump in OFF position INSTALLING UV LAMP amp UV CONTROL BOX Remove UV control bo
14. or up to 4 start times per day To review start times press NEXT To clear start times press CLEAR To change start times repeat steps A and B TO SET DURATION TIMERS FOR PROGRAM A NOTE STATION 1 Filter Sump 1 STATION 2 Filter Sump 2 Turn rotary dial to A ZONE DURATION The cursor will blink over STATION 1 To select filter flush duration for STATION 1 press Plus or Negative key to advance to desired duration for 1 99 minutes then Press ENTER Repeat Step A for Station 2 To review filter flushing durations press NEXT to clear a flushing duration press CLEAR and to modify a flushing duration repeat Step A TO SET THE DAYS FOR FILTER FLUSHING Turn rotary dial to DAY OF WEEK The cursor blinks over M for MONDAY To activate a day for flushing press ENTER The cursor advances to the next day A flag will appear over the days of the week indicating active flushing days Flushing will NOT occur on days without the flag Repeat steps A and B Any or all days of week may be selected Once filter flushing times have been programmed turn rotary dial to AUTO and programming is now complete ORBIT TIMER MAINTENANCE Battery Replacement The AA size alkaline battery is replaceable if necessary Should the AA batteries go bad slide off the front cover and remove them Then put in the new batteries and slide the front cover back on BATTE
15. rlines ROUTINE MAINTENANCE FILTER REPLACEMENT PROCEDURE 1 Perform CLEANING PROCEDURE steps 1 8 2 Install the filters into the appropriate sump the sediment filter into the far left hand sump and the carbon filter into the center sump CAUTION Be sure sump with metal liner is installed onto UV head 3 Replace each sump as each filter is installed 4 Plug system into electrical outlet Turn on water supply and check for leaks Flush system for several minutes to remove carbon fines UV LAMP REPLACEMENT PROCEDURE 1 Disconnect system from electrical outlet 2 Shut off feed water supply valve and open downstream faucet or hand piece to relieve system pressure CAUTION Do not attempt to remove sumps until water flow stops This reduces pressure inside the System so sumps may be safely removed 3 Remove sump from UV head and set aside CAUTION Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light WARNING DO NOT ATTEMPT TO REMOVE QUARTZ SLEEVE Damage to the system and personal injury may occur if the sleeve is removed incorrectly Contact your dealer or O So Pure if quartz sleeve is broken or needs replacement Part is DWS QSBB 4 Clean quartz sleeve carefully using vinegar to remove hardness Do not use abrasive materials Rinse sleeve thoroughly with clean potable water Replace any sleeve that is damaged or that will not come completely clean 5 Gain ac
16. sump and the sump caps Check to make sure the O rings are placed within the groove of the filter sumps Be sure to lubricate the O ring with silicone grease or with glycerin Check fittings either brass or quick connect and all clamps notice if any are damp Most fittings can be tightened with pliers f the leak is coming from inside the UV sump completely disconnect unit and ship back for repairs DO NOT RETURN THE FILTERS IF THERE IS LOW PRESSURE Check the two 2 pressure gauges located on the top of the metal bracket The first pressure gauge left side facing the system reflects the incoming water pressure If this gauge reads below 25 PSI call your municipal water company regarding extremely low water pressure The DWSPOE requires a minimum of 40 PSI to operate properly Now check the second pressure gauge right side when facing the system if there is a pressure differential of MORE THAN 20 25 PSI either the filters are clogged up or the waterlines are plugged Under normal circumstances and when the filters are fairly new the pressure differential between the two gauges should not exceed approx 4 6 PSI IF THERE IS A MAJOR PRESSURE DIFFERENCE BETWEEN THE 2 GAUGES USE THE FOLLOWING DIRECTIONS Check the installation or replacement dates if dates reflect more than 8 months order new filters Shut off water supply to the unit and unplug the power cord Check the number of flushes to the unit It
17. that contact bleach thoroughly with clean potable water CAUTION Read the WARNINGS on the bleach container before using CAUTION Handle sanitizing solution carefully Avoid contact with unprotected areas 1 Disconnect system from electrical outlet 2 Mix sanitizing solution Mix 1 cup of household bleach and 1 cup of clean potable water in the bucket Mix solution well CAUTION Use care when sanitizing UV head Do not get the UV control module or connectors wet CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch O rings or gaskets Use the spanner or sump wrench for removal only 3 Add sanitizing solution into the system Add 2 cups of sanitizing solution to the sump that contains the UV lamp 4 Slowly open the feed water supply valve Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE 5 Open all downstream faucets or hand pieces Keep all faucets or hand pieces open until a chlorine smell is detected at each one then close that faucet or hand piece NOTE Water lines downstream from UV housing must be disinfected to destroy any bacteria that might remain in the pipes 6 Verify disinfection solution has reached every water outlet downstream of UV system Solution must remain in the system for at least four hours 7 Open outlet valve and let water flow for 5 minutes to flush disinfection solution from wate
18. to a 50 rebate on the purchase of an O SO Pure water system Purchaser Info Referring Party Info Name _ ___ O O Name Practice Name gt o Practice Name E Address O Address City State Zip o oS o City State Zip o Email S Email s Phone Phone S Redemption Instructions amp Restrictions e Purchaser o Fill out the Purchaser information above This also registers you for making future referrals We will contact you for your SSN TIN o Present this certificate to your dealer at time of order Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system e Dealer o Dealer and dealer employees are not eligible for referral fee o When submitting your purchase order to O SO Pure include an image of this certificate clearly showing the purchaser information rebate will be sent by O So Pure directly to the purchaser identified above o Certificate must be accompanied by a purchase order e Referring party o One 1 referral fee will be paid per eligible O SO Pure water system o Referring party must own O SO Pure equipment o To register FAX this sheet with Referring Party Information filled out email address is required for communication O SO Pure will email IRS form W 9 to be completed and submitted 1099 will be issued according to IRS rules in effect o O SO Pure reserves the right to determine form of disbursement e g che
19. x and mounting screws from packaging and set aside Remove UV lamp from packing tube and inspect it for any damage DO NOT INSTALL A DAMAGED UV LAMP NOTE Hold UV lamp by ceramic ends ONLY being sure not to touch the glass Connect UV lamp into four pin socket that is connected to the bottom of the UV control box by a short cable that allows for correct insertion depth Carefully insert the UV control box with UV lamp through the mounting bracket into the quartz sleeve making sure that the cable does not twist or curl Once installed mount the UV control box on top of the mounting bracket using the four screws and one lock washer provided for grounding purposes Plug the UV control box into an electrical outlet only after the rest of system install is complete ATTACHING THE FILTER FLUSH CYCLE DRAIN TUBING If system is mounted inside a building run one length of supplied 3 8 blue tubing from the O SO PURE UV water system to the drain via the universal DLA G drain adapter provided 20 SEDIMENT 20 CARBON UV CHAMBER FIGTER BLOCK FILTER SUMPI 1 sug 2 FILTER FLUSH BOTTOM OF WATER OUT TO DRAIN OR SUMP 2 DRAIN LINE ae ADAPTER Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE Take the red clip off of the John Guest Inline Ball Valve and insert 3 8 tubing located on the lower elbow on the right side of the POE mounting bracket see above imag
20. y burn out they do lose their disinfection power after 9 000 hours or approx 375 days of continuous use Use only O So Pure UV lamps as they are specifically designed for the DWS POE system to deliver high quality drinking water NOTE UV lamp should remain on AT ALL TIMES during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes CLEANING DISINFECTING AND ROUTINE MAINTENANCE PROCEDURE Have all components on hand and ready before beginning procedure A clean work area and equipment are essential to properly clean and or disinfect the system i e clean hands tools work surface and containers EQUIPMENT NEEDED Safety glasses Liquid Dish Soap Plastic Bucket Rubber gloves sanitary Household Bleach Unscented O Ring Lubricant Silicone Based Wash cloth clean and lint free Only 5 Sodium Hypochlorite Installation amp User s Manual for Predator Whole Building UV Water Supply DWS POE CLEANING PROCEDURE 1 Disconnect system from electrical outlet 2 Mixa mild cleaning solution of dish soap and clean potable water in a plastic bucket 3 Close the incoming or feed water supply valve and open a faucet or hand piece downstream to relieve system pressure 4 Close valves at bottom of each sump and disconnect the fittings shown in the image below CAUTION Do not attempt to remove filter housing og MENT Oooh sumps until the water flow stops T

Download Pdf Manuals

image

Related Search

Related Contents

SYSTÈME POUR ORTEIL EN MARTEAU PHALINX®  Whirlpool GR2FHTXVL00 User's Manual  Etiquette - Plant Products  Fiscube Audi Einbau und Bedienungsanleitung  Herunterladen  Toshiba Satellite C855-S5234  Samsung EPEL SBS med Twin Cooling, 495 L Bruksanvisning  BRC FuelMaker  Pioneer PRS-A900 AV receiver  取扱説明書 TO  