1. ENGLISH 7 1 ELECTRONIC KEY IT 400 K only The IT 400 K may be armed and disarmed through the Control panel electronic key situated on the front panel or with a remote DAY and electronic key optional The control panel is supplied with 2 electronic keys already coded Control panel The control panel can self learn and memorize up to 8 armed Night different codes Available upon request there are also receptacles for electronic key series Magic and Living On the receptacle there are 3 LEDs that signal control panel full armed On mode partially armed Night mode and DAY mode see figure on the right W LED Control panel armed ON Red Has the same functions as LED ON on the panel When the electronic key is inserted the LED emits the following signal 1 Lit during exit time after exit time has expired flashes until panel is disarmed Receptacle on front panel Remote receptacle Electronic ke W LED Control panel armed Night mode Red Has the same functions as LED NIGHT on the panel When the electronic key is inserted the LED emits the following signal 1 The LED will flash at the end of the exit time until panel is disarmed W LED DAY mode and Alarm Memory Green 1 When control panel is in DAY mode the LED flashes 2 This LED will light during the exit time if one of the 7 zones is triggered 3 After an alarm trigger this LED will light and remain lit until the control pa
2. L7 L8 are Fire panic and anti sabotage W All 7 zones Terminals 18 to 23 and 25 to 29 can be programmed through the dip switch as normally closed NC or balanced with end of line resistance 4 7 K ohm W The first 2 burglary zones L1 gt L2 Terminals 18 19 20 may be programmed either as delayed or immediate while L3 gt L4 Terminals 21 22 23 are only immediate The remaining 3 zones anti sabotage fire and hold up Terminals 23 24 25 26 27 28 29 are always active If the control panel is programmed using end of line resistors you Neem Must place a resistor of 4 7 K ohm in series with the sensors installed If the value of this resistor is changed for example short circuit the panel will trigger an alarm Wii lloly BE For the alarm to be triggered the line must remain open for more then 0 3 seconds 6 1 BALANCE RESISTOR CONNECTION Note the location of 4K7 end of line resistor see the figure on the right Control Panel Sensor Alarm output zone NC Balanced line 7 0 KEY The IT 400 IT 400 K may be armed and disarmed through the key situated on the front panel or with a code made of up to 6 digits IT 400 D only Remote arming is possible through remote electronic key optional available only for IT 400K that incorporates on board the electronic key interface or you may use any form of NC key switch with IT 400 and IT400 D IT 400 series instruction manual Page 9
3. tampering of the sensors installed insertion of false electronic key and low battery condition will trigger the internal and external siren volt free alarm relay Terminals 9 10 11 and 12 13 14 15 16 17 The opening or unbalancing of one of the zones L1 L4 causes Flashing on the panel of the LED corresponding to the zone triggered until the control panel is re armed Lighting of the DAY LED on the panel and electronic key receptacle until the control panel is re armed Activation of the indoor and outdoor siren alarm relays Terminals 9 to 17 for the time programmed If when the control panel is armed there is an open or unbalanced zone LN or low battery the control panel will arm anyway but if the cause persists at the end of the exit time the control panel will go into alarm Page 16 IT 400 series instruction manual ENGLISH 16 0 DISARMING DAY mode To disarm the panel gt gt 2 1 2 3 4 5 IT 400 Rotate the key in DAY position IT 400 K Insert the key into the key holder for less than 5 sec IT 400 D Digit the access code on a keypad and press The panel will disarm The LED ON or NIGHT will go off If while armed an alarm has been triggered when the control panel is disarmed the LED of the triggered zone will flash until the control panel is again armed This indicates Alarm memory To cancel the alarm memory in IT 400 D IT 400
4. NIGHT will flash to indicate maintenance mode 4 Remove bridge J8 5 IT 400K only Insert the Master key and wait until the LEDs ON DAY and NIGHT fast flash twice to indicate that the master key has been memorized If this does not happens repeat points 4 and 5 6 Insert bridge J8 7 Exitfrom maintenance by putting to OFF dip 1 of dip switch A 8 Close the cover After following the above procedure all of the electronic key codes memorised in the IT 400K will be cancelled and the access code programmed by the user in the IT 400 D will return to the pre programmed factory code of 123456 and the control panel will auto matically set to DAY status Page 18 IT 400 series instruction manual ENGLISH 18 0 TECHNICAL CHARACTERISTICS Power 230 Vac 50 60 Hz Current drain in stand by 65 mA Current drain in alarm 270 mA max Line sensitivity 300 milliseconds Alarm time 60 120 180 seconds or infinite programmable Entry time 15 30 or 60 seconds programmable Exit time 30 or 60 seconds programmable Relay contacts panic alarm 1 A max Relay contacts fire alarm 8 A max Relay contacts indoor siren 8 A max Relay contacts outdoor siren 8 A max SMD technology Rechargeable battery housing 12 V 7 A h max ABS container 12 V 17 A h max metallic container Dimensions 275x220x80 mm ABS container 310x315x80 mm metallic container Weight 1 5 Kg ABS container 4 9 Kg metallic contain
5. triggered until the control panel is re armed Lighting of the DAY LED on the panel and electronic key receptacle until the control panel is re armed Activation of the indoor and outdoor siren alarm relays Terminals 9 to 17 for the time programmed If when the control panel is armed there is an open or unbalanced line NULO or low battery the control panel will arm anyway but if the cause persists at the end of the exit time the control panel will go into alarm IT 400 series instruction manual Page 15 ENGLISH 15 0 PARTIAL ARMING NIGHT mode All the zones are active except those by passed see paragraph 13 0 a gt 2 gt 1 2 Procedure IT 400 Rotate the key to NIGHT position IT 400 K Insert the key into the key holder for more than 5 sec IT 400 D Digit the access code on a keypad and press During the exit time the following will take place The NIGHT LED on the panel and electronic key receptacle will light f however there are zones open or unbalanced the LED of the triggered zone on the panel and the DAY LED on the panel and electronic key receptacle will light At the end of the exit time The NIGHT LED on the panel and electronic key receptacle will flash The Alarm memory LED on the electronic key receptacle will go off The control panel is now armed in NIGHT mode Violation or unbalancing of the 24 hour fire and panic zones
6. 132 pesec2esessr Jpsescoeseo2esso2ess DDA B Remote Key Impulse LI i 1 ri rl F INWIN LU Y W W W UU Bus R8485 fj eme ey ON OBE L1 L2 L3L4 L5l6 L718 A L g g 1 L Normally closed lines GND 12 Vdc auxiliary output NOCNC NCNOC NOCNC NC NA C NO C NC NC X Outdoor siren relay Fire alarm relay n L Volt free relay contacts Panic alarm relay i Fire alarm ling 7 Panic alarm line Indoor siren relay Relay with selectable operation 8 24 hours antitamper line 1 2 Auxiliary output 12 Vdc Imax 1 A LS This output is always active with control panel armed or disarmed 345 Normally opened N O Common C Normally closed N C Volt free relay contact for fire gas alarm Imax 8 Amp This relay is activated for the programmed time when the zone L6 is triggered 678 Normally closed N C Normally opened N O Common C Volt free panic alarm relay Imax 1 A This relay activates for 10 sec At the opening of line L7 panic audible non audible 9 1011 Volt free change over relay alarm output for internal siren Imax 8 A Normally opened N O Common C Normally closed N C This relay is activated if burglary sabotage or audible panic alarms are triggered 12 13 14 Volt free change over relay alarm output for external siren Imax 8 A Normally closed N C Normally opened N O Common C This relay is activated if b
7. 4 hours antitamper line 30 31 32 RS 485 BUS serial interface for connecting expansions and programming peripherals 33 34 Normally closed Remote key input for total arming IT 400 D 35 36 37 Not present on IT 400D IT 400 K only 33 Negative 34 Remote electronic key input see page 10 35 Output for remote LED that indicates control panel armed day position This is located on the remote electronic key base see page 10 36 Output for remote LED that indicates alarm memory This is located on the remote electronic key base see page 10 37 Output for remote LED that indicates control panel armed for night functions This is located on the remote electronic key base see page 10 38 Negative output for telephone dialler that signals burglary and tamper Imax 100 mA This output remains active for one second 39 Negative output for Unit ON signalling Imax 100 mA This output remains active during the ON status 40 42 Power input for control panel 19 Vac 41 NOT USED Page 20 IT 400 series instruction manual PROTECTING PEOR TRE i SYSTEMS Sut Via del Melograno N 13 00040 Ariccia Roma Italy Tel 39 06 97249118 Fax 39 06 45557618 Tre i Systems e mail m tomasinoQ treisystems com Website www treisystems com Tre i Systems is not responsible for inappropriate use of it s products For any problems refer to the nearest authorized agent or directly to Tre i Systems
8. 5 15 0 Partial arming NIGHT mode 16 16 0 Disarming DAY mode 17 17 0 Low battery alert 18 18 0 Reset to factory code 18 19 0 Technical characteristicS s0cvrrrrcriricerirrir sereni ce ierivi ivi riviioricineo 19 20 0 Connected Version IT 400 D K vsrssrrrrrirricrirrini screen ana an nana anui 20 Page 1 ENGLISH Congratulations for buying the IT 400 a user friendly hardwire control panel Every unit is assembled using the latest microprocessor technology followed by robotic assembly methods and computerized test resulting in an apparatus secure and reliable 1 0 DESCRIPTION The IT 400 is an elaborate hardwire control panel with 4 3 zones divided as follows The first 4 burglary zones are programmable and may be configured as Day Night normally closed N C or balanced Each of these zones has automatic by pass feature which goes into effect after 4 alarm cycles In addition Zone 1 and Zone 2 can be configured as delayed or immediate The remaining 3 zones fire panic and sabotage are not programmable and always active The control panels of the IT 400 series may be armed by means of a mechanical key IT 400 an electronic key IT 400 K or keypad IT 400 D Remote arming key is optional The creation of a group of zones that function in Day or Night permits you to rapidly arm the control panel without modifying the way the pa
9. D on the panel The LED remain active until the next arming of the panel to indicate Alarm memory Opening of Li gt L4 when functioning in N C or the violation of the zones both not excluded will cause The lighting of the LED on the panel corresponding to the triggered zone only for the time that the zone remains open or unbalanced IT 400 series instruction manual Page 17 ENGLISH 17 0 LOW BATTERY ALERT Incase of mains failure the power is supplied by the battery When the battery voltage goes below 10 5 V the control panel will signal the event with the lighting of the LOW BATTERY LED on the panel The LED will remain active until the control panel is re armed to signal Low battery memory e lf LOW BATTERY alert continues check if the mains is present green POWER LED lit check the mains fuse and if the battery charger is functioning correctly 13 8 Vdc on cables of battery If all functions correctly then the battery must be replaced 18 0 RESET TO FACTORY CODE IT 400 K IT 400 D This is an emergency procedure to be used for example in the case that the owner has lost all the electronic keys IT 400 K or forgot the access code IT 400 D 1 Open the cover of the control panel and disconnect all power both 230 Vac and 12 V battery supply Note This will provoke a TAMPER ALARM 2 Putto ON dip 1 of dip switch A 3 Re connect the power to the control panel The LEDs ON and
10. IT 400 400K 400D 7 hardwired zones control panels IT 400 D 3t x User manual TRE i SYSTEMS S r l Via del Melograno N 13 00040 Ariccia Roma Italy Tel 39 06 97249118 Fax 39 06 45557618 Tre i Systems PR OTECTING peor e mail m tomasino treisystems com Website www treisystems com I T 40 O series 7 zone hardwire control panels 5 models I T 400 I T 400 K I T 400 D Summary Page 1 0 Description n iii iii ici 2 ZO Installation eI CDED I 3 3 0 Terminal block connections eere eee esie es in esie naar aaa n naa n aiam ananas annua na 4 4 0 Mains power connection DR 4 1 Mains power fuse change iii 7 4 2 E A ea th ae UR I ORO arn 7 5 0 Front panel De 6 0 Zone d scription sarssvssssssisscsenssedconsscsseceessesssatsossesssscssssstssszcostssssaestssssseatscssesstecsss 9 6 1 Balance resistor connection iii 9 10 gt O E Em 9 7 1 Electronic key 10 7 2 Remote receptacle installation 10 7 3 Electronic key sabotage 2 10 8 0 Mechanical switch lock key 9 0 Maintenance mode 10 0 Programming 12 11 0 User code esesees 13 12 0 Self learning of the electronic key rrrrcrricriieriririieiinririierini nie 13 13 0 BY DASSING zones 14 14 0 Total arming ON mode 1
11. K press any key on the keypad or change the status of the control panel by first arming and then disarming the control panel To cancel the alarm memory in IT 400 it is sufficient to change the status of the control panel by rotating the key before in ON position and then in DAY position The unbalancing of the 24 hour zone Terminals 28 and 29 the sabotage of zones L1 gt L4 and the inserting of false electronic keys will cause Slow flashing of 24 H LED on the panel The LEDs will remain active until the next arming of the panel to indicate Alarm memory The activation of the indoor and outdoor siren alarm relays Terminals 9 to 17 for the time that has been programmed The unbalancing of the fire zone Terminals 25 and 26 causes Slow flashing of the FIRE LED on the panel The LEDs remain active until the next arming of the panel to indicate Alarm memory The activation of the fire alarm relay Terminals 3 4 and 5 for 30 seconds The unbalancing of the panic zone Terminals 27 and 28 causes Slow flashing of the PANIC LED on the panel The LEDs remain active until the next arming of the panel to indicate Alarm memory The activation of the panic alarm relay Terminals 5 6 and 7 for 10 seconds The activation of the indoor and outdoor siren alarm relays Terminals 9 to 17 for the time they have been programmed Low battery level load under 10 5 V causes Slow flashing of the LOW B LE
12. ce time 15 sec ON OFF Entrance time 30 sec ON ON Entrance time 60 sec Entrance time Zone 2 OFF OFF Immediate OFF ON Entrance time 15 sec ON OFF Entrance time 30 sec ON ON Entrance time 60 sec Automatic zone exclusion after 4 alarm cycles OFF NO ON YES Silent or audible panic OFF silent ON audible DIP SWITCH B OPTIONS ON Firerelay follows the timing of the indoor siren OFF Fire relay blocks only when the control panel is disarmed DAY ON External siren has only one alarm cycle OFF External siren completes all alarm cycles Indoor siren alarm time OFF OFF Persistent sound OFF ON Alarm time 1 min ON OFF Alarm time 2 min ON ON Alarm time 3 min External siren alarm time never more than that programmed on the indoor siren OFF OFF Persistent sound OFF ON Alarm time 1 min ON OFF Alarm time 2 min ON ON Alarm time 3 min Programming of lines L1 L2 L3 L4 burglary and L6 L7 L8 fire hold up and tamper OFF OFF All lines disabled OFF ON Lines normally closed NC ON OFF Balanced lines end of line resistor 4K7 Ohm necessary ON ON NOT USE At the end of programming close the cover of the control panel making sure that dip 1 of dip switch A is in OFF position normal function and that the tamper button is closed Page 12 IT 400 series instruction manual ENGLISH 11 0 USER CODE IT 400 D only The control panel is supplied with factor
13. central assistance centre Tre i Systems reserves the right to modify the product without warning Made in Italy
14. ed triggering this line will cause e Flashing of the FIRE LED on the front panel until the control panel is re armed to signal Alarm memory Activation for the pre programmed time of the fire relay output Terminals 3 4 5 27 28 L7 Hold up alarm trigger input With control panel armed or disarmed triggering this line will cause Flashing of the PANIC LED on the front panel until the control panel is re armed to signal Alarm memory f you have programmed a silent hold up alarm after this alarm has been triggered only the panic relay will activate Terminals 6 7 8 for 10 seconds f you have chosen to program the hold up alarm with an audible alarm signal triggering this alarm output will activate the hold up alarm relay terminals 6 7 amp 8 for 10 seconds and also the internal and external sirens relays Terminals 9 through 17 for the programmed alarm time 28 29 L8 24hour anti tamper trigger input With control panel armed or disarmed triggering this line will cause Flashing of the 24 H LED on the front panel until the control panel is re armed to signal Alarm memory Activation of the internal and external sirens relays Terminals 9 through 17 for the programmed alarm time IT 400 series instruction manual Page 5 ENGLISH 30 31 32 33 34 35 36 37 38 39 40 41 43 42 FUSES FI 1A F2 1A F3 1A F3 1A Page 6 RS 485 BUS serial interface for connecting expansions and programmin
15. er gt Do not litter Separate and discard the packaging ma terials in the containers depending on the rules in force at the place of residence FA X Do not litter Turn the device and the batteries over to a designated disposal at the end of lifetime Latest revision 05 20 2011 IT 400 series instruction manual Page 19 ENGLISH ON oe Fm pom p 42 19 Vac ore tmu E mu A TES ao 12345678 J8 12345678 F121A F2 1A F3 1A F4 1A Q 40 e 19 Vac Y PC board Auxiliary Battery polarity Short circuit Q 39 e Unit ON Dip switch A Dip switch B protection Outputs inversion transformer D 38 e Negative impulse 37 D Normally operation a l Volt vee relay contada Electronic remote ke z tem green TSI y T versi n O 34 A O 34 Remote key Reset factory condition E 12 Vdc to Terminal 14 33 H 32 NO i IT 400 400D version i Negative s sae ver ienene enza 1234567891011 em 2223242526272829 303132 9 ESQODSESSSOC ESOODESHODSSOOHDSSY HOT Vi 1 1 1 1 DI IQM LU A UU SU EU doh m Li L2 L3l4 L516 L718 LI 1 t Normally closed lines Es GND NOCNC NCNOC NOCNC NCNO C NO C NC NC T Outdoor siren relay 12 Vdc auxiliary output Fire alarm relay L RX f Voltiresireldy contacts AS ART L8 Bre dim ine Indoor siren relay Relay with selectable operation i L7 Panic alarm line L8 2
16. g peripherals The Buzzer must be connected from 12 Vcc and buzz terminal Normally closed Remote key input for total arming used on IT 400 amp IT 400D only Not used on IT 400 Negative output for telephone dialler that signals burglary and tamper Imax 100 mA This output remains active for one second Negative output for Unit ON signalling Imax 100 mA This output remains active while the panel is armed Power input for control panel 19 Vac NOT USED Rapid fuse to protect the internal power supply Rapid fuse to protect the auxiliary 12 Vdc outputs Terminals 1 and 2 Rapid fuse to protect inversion of polarity of the battery Delay action fuse to protect short circuit of the transformer IT 400 series instruction manual ENGLISH 4 0 MAINS POWER CONNECTION Before making this connection be sure that cable being use is volt free and insert the bare wire on the cable used completely into the terminal block as seen on the right Presence of main power is indicated on the front panel when the green POWER LED lights up 4 1 MAINS POWER FUSE CHANGE L One of the two phases of the mains power is protected by a delay action fuse T800 mA The fuse is incorporated in the terminal block seen on the right hand side In case of fuse burn out it can be easily changed by pulling upward the fuse holder as shown on the right Change the fuse and plug it back in with downward pressure Ground connect
17. ion 4 2 GROUND CONNECTION It is important to have a good ground connection to avoid electrical disturbances to the control panel Therefore the terminal indicated as ground see on the right must be connected to a good ground connection ATTENTION Electrical building installation must be equipped with a bipolar automatic switch In case of ordinary maintenance disconnect the unit from the mains IT 400 series instruction manual Page 7 ENGLISH 5 0 FRONT PANEL L1 TO L4 ZONE LEDS Control panel disarmed DAY 1 Lit indicates line open or un balanced 2 Flashing indicates alarm memory 3 Off signals line closed normal status Control panel armed ON and NIGHT 1 Off signals line closed normal status 2 Lighting during the exit time signals line in alarm 3 Flashing after the exit time signals alarm memory ON LED on the panel and remote electronic key 1 Lights up during the exit time then flashes until panel is disarmed AS LED With control panel disarmed or armed Day ON Night 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory DAY LED on the panel and remote electronic key 1 Flashes during the Day status 2 Lighting during the exit time signals line open or un balanced 3 Lighting during the ON and NIGHT status signals alarm memory PANIC LED With contro
18. ize a configuration At the end of configuration switch the control panel to the DAY mode for memorization IT 400 IT 400 K Turn the key of the control panel to the DAY position IT 400 D Digit to bring the control panel to DAY mode Page 14 IT 400 series instruction manual ENGLISH 14 0 TOTAL ARMING ON mode W Procedure gt T 400 Rotate the key in ON position IT 400 K Insert the key into the key receptacle for less than 5 sec IT 400 D Digit the access code after which press key W During the exit time the following will take place The ON LED on the panel and electronic key receptacle will light f however there are zones open or unbalanced the LED of the triggered zone on the panel and the DAY LED on the panel and electronic key receptacle will light W Atthe end of the exit time The ON LED on the panel and electronic key receptacle will flash The Alarm memory LED on the electronic key receptacle will go off The panel is now totally armed ON mode 1 Violation or unbalancing of the 24 hour fire and panic zones tampering of the sensors installed insertion of false electronic key and low battery condition will trigger the internal and external siren volt free alarm relay Terminals 9 10 11 and 12 13 14 15 16 17 2 The opening or unbalancing of one of the zones L1 L4 causes A Flashing on the panel of the LED corresponding to the zone
19. l panel disarmed or armed Day ON Night 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory Night LED on the panel and remote electronic key 1 Lights up during the exit time then flashes until panel is disarmed FIRE LED With control panel disarmed or armed Day ON Night 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory 1 Are used to associate zones to Night status and to digit access code IT 400D only POWER LED Always lit signals 230 Vac present LOW BATTERY LED Control panel disarmed or armed Day ON Night 1 Off indicates battery charged normal status 2 Litindicates low battery ARMING DISARMING KEY 1 Model IT 400 Mechanical key switch for arming and disarming The control panel may be armed also with remote optional NC mechanical key 2 Model IT 400 K Electronic key for arming and disar ming the control panel is supplied with the unit Remote electronic key is optional 1 Model IT 400 D Digital keypad for arming and disar ming The control panel may be armed also with remote optional NC mechanical key Page 8 IT 400 series instruction manual ENGLISH 6 0 ZONE DESCRIPTION The series IT 400 control panels It 400 IT 400 K IT 400 D have 7 zones in total of which L1 gt L4 are burglary alarm zones and L6
20. mote switch lock the con trol panel will not respond anymore to the remote switch lock 9 0 MAINTENANCE MODE With the control panel in this mode it is possible to 1 2 3 Open the control panel without triggering an alarm Re set to factory codes IT 400 K and IT 400 D only Enter into the programming mode To enter into Maintenance With cover open Set switch 1 of dip switch A to ON for programming The LED ON and NIGHT will flash to indicate maintenance mode With cover closed panel already installed Set the panel in ON mode with the master key in IT 400 K and during the exit time open the cover and set switch 1 of dip switch A to ON for programming The LED ON and NIGHT will flash to indicate maintenance mode To exit Maintenance mode Finished the maintenance operations set switch 1 of dip switch A to OFF and during the exit time close the cover and set the panel in DAY mode NOTE If at the end of the exit time the panel key is still in ON mode it will automatically arm IT 400 series instruction manual Page 11 ENGLISH 10 0 PROGRAMMING With the control panel in maintenance mode it is possible to program it using dip switches A and B as listed below DIP SWITCH A OPTIONS 1 2 3 4 7 8 ON Sets control panel in maintenance mode OFF Sets normal functioning ON Exit time 60 sec OFF Exit time 30 sec Entrance time Zone 1 OFF OFF Immediate OFF ON Entran
21. nel has been programmed For IT 400 K only unauthorized attempts to arm the control panel will activate the anti sabotage zone which will block the use of the electronic key and at the same time trigger the alarm The extreme flexibility of the different programming methods allows the end user to personalize the installation based on his needs Other Characteristics Day Night arming Programmable relay alarm outputs Separate relay alarm outputs for internal sirens Remote indication for unit ON Low battery indication Output for siren with or without battery back up Relay output for panic an fire Page 2 IT 400 series instruction manual ENGLISH 2 0 INSTALLATION For an easy and correct installation follow the steps listed below PON o00229 Remove the ABS control panel cover 230 Vac Fix the base of the panel to the wall aL Connect all the sensors and sirens to the control panel Connect the mains 230 Vac power source to the 3 terminals indicated on the right Be sure to connect a good ground source D S to the centre terminal ped Be careful that the cable being connected is without tension o O gt MI An o Program the unit using dip switch A and B see page 32 e Connect the battery using the red and black terminal which indicate the polarity Red for positive and black for negative you will see the test LED flashing This indicates that the control panel is in Maintenance mode Re position and fix the con
22. nel is disarmed and re armed This is indication of alarm memory 7 2 REMOTE RECEPTACLE INSTALLATION Terminal block S5 std e panel DOVED To allow arming of the control panel from more then one remote position it is necessary to wire up to terminals 33 34 35 36 and 37 of the IT 400 K to the terminals on the back side of the receptacle as shown in the figure on the right 7 3 ELECTRONIC KEY SABOTAGE IT 400 K only The control panel is protected against attempts to insert a false electronic key f a person inserts a wrong key 10 times the internal siren relay Terminals 9 10 11 and external siren relay Terminals 12 13 14 15 16 17 will be triggered for the alarm time programmed Page 10 IT 400 series instruction manual ENGLISH 6 0 MECHANICAL SWITCH LOCK KEY remote The IT 400 and IT 400 D may be remote armed disarmed by means of a switch lock connected to terminals 33 and 34 Using a remote switch lock only total arming disarming is possible ON position and Day position Night arming is not possible If the control panel has been armed with a remote mechanical switch lock Terminals 33 and 34 open it is possible for the control panel to be disarmed by means of the front panel key or numeric code for IT 400 D or the remote switch lock If the control panel has been armed with the front panel key or by numeric code IT 400 D and you attempt to change the status with the re
23. trol panel cover Connect the mains power input wire to a 230 Vac source It is suggested that this power Source be obtained between the AC power meter and the main circuit breaker After this is done the green LED POWER will light up Be sure that the 24 hour anti sabotage line is closed red LED 24 H OFF Set the panel in DAY mode The control panel will go into disarmed status IT 400 Rotate the key in DAY position IT 400 K Automatically goes to DAY status IT 400 D Automatically goes to DAY status NOTE When the panel has no mains and no battery voltage connected and you power it the IT 400 will go to the status of the panel KEY switch IT 400K and IT 400D will automatically go to DAY status IT 400 series instruction manual Page 3 ENGLISH 3 0 TERMINAL BLOCK CONNECTIONS ON oe o 43 e 19 Vac ore co I nuum Reza 12345678 J8 12345678 Fi 1A F2 1A F3 1A F4 1A 9 4 19 Vac y PC board Auxiliary Aids polarity Short circuit GJ 40 e Unit ON Dip switch A Dip switch B protection Outputs inversion transformer 139 e Negative impulse D 38 e D Q 37 C Normally operation L Volt free relay contacts Q 36 B TS1 Buzz Q 35 9 A Reset factory condition El a 12 Vdc to Terminal 14 L O AT 3 Q Negative 12345678 91011 1213141516 17 18 1920 21 2223242526272829 303
24. urglary sabotage or audible panic alarms are triggered Bridging the connector TS1 as shown above the common of the relay Terminal 14 is connected to 12 Vdc 15 16 17 Volt free change over relay alarm output for external siren Imax 8 A Normally opened N O Common C Normally closed N C This relay is activated if burglary sabotage or audible panic alarms are triggered Page 4 IT 400 series instruction manual ENGLISH 18 19 L1 Programmable Normally Closed N C immediate or delayed line di With the control panel armed triggering this line will cause Flashing of the corresponding LED on the front panel until the control panel is re armed to signal Alarm memory Lighting of the DAY LED on the front panel and on receptacle of electronic key until the control panel is re armed to signal Alarm memory Activation of the internal siren Terminals 9 10 11 and external siren Terminals 12 to 17 alarm relays for the pre programmed time With the control panel disarmed triggering this line will cause Lighting of the corresponding LED on the front panel for the time that the line is in alarm What has been written above for L1 is valid for all 4 burglary alarm zones with the only difference that L1 and L2 can be either programmed as delayed and immediate while lines L3 and L4 are only immediate 24 Notused 25 26 L6 Fire or gas alarm trigger inputs With control panel armed or disarm
25. y programmed code of 123456 This code can be modified using the following procedure With the control panel in DAY mode digit it existing code new code This code may be made up from a minimum of 1 and a maximum of 6 digits from numbers between 0 and 9 f you forget the user code it is possible to Reset to factory code see paragraph 18 0 12 0 SELF LEARNING OF ELECTRONIC KEY IT 400 K only The control panel can learn up to 9 different electronic key codes Receptacle on front panel maintenance mode and program other keys in the memory If the Master key is lost the reset to factory defaults procedure must be done see paragraph 18 0 Procedure for self learning code 1 Insert the Master key for less than 5 seconds and during the exit time open the front cover and set switch 1 of dip switch A in ON position The LEDs ON and NIGHT will flash to indicate maintenance mode 2 Open the jumper J8 The LED ON DAY and NIGHT will light to indicate self learning of codes Insert a key in the front panel receptacle and wait for two fast flash of the LEDs ON DAY and NIGHT This confirms that the key code has been read Insert jumper J8 to confirm the memorization of the key Repeat the above procedure for all the keys to be memorized It is possible to memorize up to 9 keys including the Master key NOTE If you try to memorize a previously memori
26. zed key the panel will not use a new location of memory only the flashing of LED ON DAY and NIGHT will happen If all the 9 memory locations have been occupied the panel will not accept new keys In this case the master key as explained in paragraph 18 0 and all the available keys must be re programmed as described above IT 400 series instruction manual Page 13 ENGLISH 13 0 BY PASSING ZONES It is possible to partially arm the system NIGHT mode by by passing some of the zones NOTE The control panel is supplied with all the zones active E visualization of the configuration memorized IT 400 IT 400K Turn the key of the control panel to the NIGHT position EA and during the exit time press any one of the buttons GA A B C or D relative to the zones IT 400 D Bring the control panel to the NIGHT mode by digiting the access code followed by and during the exit time press ff The control panel will visualize the present state of the zones programmed for Night arming gt Ifthe LED related to the zone is lit the zone is active in NIGHT mode gt Ifthe LED related to the zone is OFF the zone is by passed in NIGHT mode HM To modify the configuration memorized To modify the memorized configuration press buttons A B C or D related A to the zones The LED will change status from lit to off or viceversa A M To memor