1. gt e e gt PP Ole Oo gt FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help
2. WARNING This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment You are cautioned that changes or modi cations not expressly approved by party responsible for compliance could void your authority to operate the equipment Q Do not use or store the Unit in such places as listed below it may cause electrocution fire or damage to the Unit or to your computer Areas exposed to direct sunlight Areas exposed in water or high pressure water flow Areas exposed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas near fire or exposed to excessive heat Areas exposed to excessive dust and smoke Q Do not put fingers or foreign objects into the sensor jack A Do not drop or expose the Unit to a strong impact It may cause damage A Caut
3. data cannot occur while the battery is removed Cautions for Using in a Low temperature Environment below 20 C When using in an environment below 20 C the battery life will be halved If the battery life has depleted to half or less under normal conditions and then is moved to an environment of 20 C or less the battery warning mark will come on and in about one day s time the battery may lose all power If you use the Unit in a low temperature environment we suggest replacing the battery as early as possible
4. out the following data processing by using the software View and Print View and print graphs and lists of recorded data Save Create and save recorded data files and text files Notes about Communication Devices When using a Data Collector you can download recorded data view the data in graph form and make all necessary recording settings without connecting to a PC When using optical communication with a Communication Port TR 50C please note that some newer functions of the TR 5i Series Data Loggers such as the warning monitoring function cannot be carried out The time necessary to download one Unit of full data varies depending upon the type of device being used A Cautions about the Infrared Communication Sensor This Unit is an infrared equipped device Do not place the Unit in areas exposed to direct sunlight directly below an incandescent lamp or near other infrared devices Placing in such an area may cause infrared communication to not work properly Also Infrared communication may not be carried out properly in a low temperature environment below 20 C Proper communication may not be possible if the infrared port is dirty During the infrared communication do not touch the infrared port or interrupt the communication Z Cautions about Changing the Battery Before replacing a battery please make sure to download any necessary data and proceed with changing the battery Downloading of
5. ENYN Thermo Recorder TR 514 TR 524 Introductory Manual Thank you for purchasing this product Carefully read and fully understand these instructions before using this unit T amp D coRPoRATION Shimadachi 817 1 Matsumoto Nagano 390 0852 Japan Tel 81 263 40 0131 Fax 81 263 40 3152 Homepage http www tandd com E mail support tandd com Copyright T amp D Corporation All rights reserved 2010 09 16504710002 1st Edition This is printed using recycled paper TR 51i Internal Temperature Sensor Type Immersion proof Package Contents Data Logger and Common Accessories for TR 51i and TR 52i TR 52i External Temperature Sensor Type Splash proof Package Contents Data Logger Temperature Sensor TR 5106 and Common Accessories for TR 51i and TR 52i Common Accessories for TR 51i and TR 52i Lithium Battery LS14250 with Tube Strap Introductory Manual including Warranty Appearance Diagram and Part Names Specifications Device Name TR 51i TR 52i Measurement Item Temperature Temperature Number of Channels 1 Ch Internal Sensor Type 1 Ch External Sensor Type Measurement Range 40 to 80 C 60 to 155 C Response Time in 90 still air About 35 minutes Measuring Accuracy Avg 0 5 C Avg 0 3 C 20 to 80 C Avg 0 5 C 40 to 20 C 80 to 110 C Avg 1 0 C 60 to 40 C 110 to 155 C Measurement Display Resolution 0 1 C S
6. clear explanations in this manual T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or for any problem caused by the use of measurement results of our product Please be fully aware of this before using our product This Introductory Manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair carefully Safety Precautions and Instructions The following items should be strictly obeyed for the safe usage of this product and for protecting yourself and other people from bodily harm and or damage to property To ensure the proper use of this product we ask that before using it you carefully read understand and follow the safety rules and precautions as outlined below A DANGER Do not take apart repair or modify the Unit It may result in malfunction or unexpected accidents Do not use any batteries other than those specified in this Introductory Manual Doing so may cause fire or malfunction If water or a foreign object enters into the Unit immediately remove the battery and stop using It may resul
7. detailed information about the operation and functions of the Data Collector TR 57DCi see the TR 57DCi Users Manual Note gt Please note that infrared communication is a function limited to the downloading of recorded data Other functions such as making Unit settings cannot be carried out For downloading one TR 51i 52i Unit at full storage capacity it takes about 60 seconds Recording settings for the Unit can be changed by using the software supplied with the Communication Port or Data Collector The factory default settings are as follows Recording Interval at 10 minutes Recording Start at Immediate Start Recording Mode at Endless Infrared Communication at Forbid Select from 15 choices 1 2 5 10 15 20 and 30 seconds or 1 2 5 10 15 20 30 and 60 minutes Recording starts immediately upon battery installation Programmed Start Recording starts on the set date and time Recording Intervals Recording Start Immediate Start Recording One Time Upon reaching storage capacity of 16 000 Modes readings recording automatically stops Measurements and the word FULL will alternately appear in the LCD Endless Upon reaching the storage capacity of 16 000 readings the oldest data is overwritten and recording continues Infrared Permit Infrared Communication will be possible Communication Forbid Infrared Communication will not be possible Function It is possible to carry
8. e for the battery to be replaced a battery life warning signal will appear Please replace the battery as soon as possible if this mark appears Gea C9 C o SLE LL OL After removing the battery wait for about three seconds until the bAtt mark appears Once this appears please insert the new battery as quickly as possible Qo fier Once If the battery is replaced before the bAtt mark appears the battery life warning signal may remain even after replacing If you change the battery at this point all recorded data will be saved If the battery is further left unchanged the display will automatically shut off If at this time a new battery is placed in the Unit the CHEC mark will appear on the display after which recording will begin again using the previously set recording conditions Note however that all previously recorded data will have been lost Estimating Battery Life The battery life warning signal will appear based upon the calculation of battery use This mark may not appear correctly if the same battery is taken out and put in therefore do not remove the battery until it can be replaced with a new one If infrared communication is set to be permitted battery life will be shortened When communication frequency is 4 times a month Recording Interval 1 second 2 seconds 5 seconds 10 seeonds or longer ere A About About About About Infrared Co
9. elect from 15 choices 1 2 5 10 15 20 and 30 seconds 1 2 5 10 15 20 30 and 60 minutes Storage Capacity Up to 16 000 readings Recording Start Method Immediate Start Programmed Start Recording Modes Endless One Time LCD Displayed Items Recording Intervals Measured Temperature Recording Status Recording Mode Infrared Communication Status Battery Life Warning Unit of Measurement Full Storage Capacity FULL Unconnected Sensor Measurement Range Exceeded Upper Lower Limit Exceeded Communication Interfaces Optical Infrared Communication Infrared Communication IrPHY 1 2 low power Communication Time When downloading a Unit at full storage capacity Optical Communication about 25 seconds TR 50U about 150 seconds other devices Infrared Communication about 55 seconds TR 57DCi Lithium Battery LS14250 Lithium Battery CR2 About 4 years 2 years if it s been selected to Permit infrared communication Waterproof Capacity Immersion proof Splash proof Dimensions H62 X W47 X D19mm excluding protrusions and sensor part Weight About 54g including battery About 55g including battery excluding sensor Power 1 Battery Life 2 40 to 80 C When using Lithium Batteries CR2 sold in stores 20 to 60 C Data Collection Devices Communication Ports TR 50U TR 50C Data Collectors TR 57DCi TR 57U RTR 57U RTR 57C Opera
10. ery LS14250 Notices about this Introductory Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this Introductory Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of the manual without the permission of T amp D Corporation All registered trademarks company names product names and logos mentioned herein or for products being used are the property of T amp D Corporation or of their respective owners TANDD T amp D and the logo of T amp D Corporation are all registered property of T amp D Corporation Specifications design and other contents outlined in the manual are subject to change without notice due to continual improvements Please follow the safety precautions outlined in the manual carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended On screen messages in this manual may vary slightly from the actual messages Please notify the distributor from which you purchased this product or T amp D Corporation of any mistakes errors or un
11. g period If the battery is replaced after the battery power has been lost Warning set limit exceeded Warning LED flashes F fid o c REC Using the Software that comes with the Communication Port or Data Collector you can make settings for the Upper Lower Limits and Judgment Time If a measurement exceeds one of the set limits the warning LED and a message will be displayed Upper Limit Exceeded If a measured temperature exceeds the set upper limit the Logger LED will alternately flash between Hi and the measurement Lower Limit Exceeded If a measured temperature exceeds the set lower limit the Logger LED will alternately flash between Lo and the measurement Starting the Warning Monitoring Function If these settings are made in an environment where one of the limits is being exceeded and recording is started the monitoring function will enter wait mode Once a measurement returns to within the set limits the monitoring function will begin to operate How to Turn Off a Warning Restart recording from the software Use Clear Warning setting from the software only via TR 50U Download the recorded data only when successfully completed Produce a condition so that CHEC is displayed see Check above Measurement Range Exceeded for TR 52i only i cer DF The temperature display blinks when the temperatu
12. ions about the Temperature Sensor When using the included Sensor TR 5106 please take note of the following Do not bend the sensor tip section or expose it to a strong impact This may cause trouble or break the wire If the fluoropolymer coated section of the sensor and or the cable has a defect or tear the waterproof capacity will be lost Inspect it before operation Insert the sensor tip to about 5cm or more to obtain on accurate temperature measurement eo gt e Only use the sensor within the sensor temperature durability range Reading the LCD Basic LCD Display When being used in very hot or cold environments the display may become difficult to read This is not a malfunction ma i iy mL ml anr uny a a wl r _ Recording REC Mark The recording status is shown here ON Recording in progress or Storage Capacity FULL BLINKING Waiting for programmed start Battery Life Warning Signal When it is time for the battery to be replaced this signal will appear Recording Mode gt One Time QD Endless Measurement and Measurements or operational messages are Message Area shown here Infrared Communication The infrared communication status is shown here Ir Mark ON Permitting infrared communication Not ON Forbidding infrared communication Battery Replacement Mark 1 When it is tim
13. mmunication Forbidden 18 months 2 years 3 years 4 years ore a About About About About infrared Communication Fermited 14 months 14 months 19 months 2 years The battery life warning signal may appear sooner than noted above Battery life will be shortened if used under the following conditions downloading data very often setting the recording interval at less than 10 seconds leaving the Unit with the warning LED blinking measuring in an environment below 20 C or leaving the Unit unconnected to the sensor for several months TR 52i Other Messages FULL Storage Capacity FULL pap Len bh MR fi i When Recording Mode has been set to One Time and the Unit reaches its storage capacity of 16 000 readings recording will automatically stop and in the LCD the measurement reading and the word FULL will alternately appear Estimation of time until FULL is displayed Recording Interval 1 second 30 seconds 1 minute 10 minutes 60 minutes Period About 4 About 5 About 11 About111 About 1 year hours days days days and 10 months Check erm paag re erm If this appears all data that was stored in the Unit will have been erased This will be displayed under the following conditions The first time a battery was inserted after purchase If the battery is replaced after having been taken out for a lon
14. n cable Communication Cable 2 Place the Unit face down on the Data Collector or Communication Port making sure that the optical communication areas are aligned properly Sa AA Data Collection Devices Communication Port TR 50U TR 50C Data Collection Devices Data Collector TR 57U TR 57DCi RTR 57U RTR 57C Recording settings for the Unit and the downloading of recorded data from the Unit can now be carried out from your computer Notes about Optical Communication Proper communication may not be possible in the following situations where temperatures are very high or very low in an environment with intense brightness higher than 5 000Ix or when the remaining battery life for the Unit is very low Downloading Recorded Data via Infrared Communication By using a Data Collector TR 57DCi it is possible to download the recorded data from a TR 51i 52i via infrared communication Getting Ready and Downloading Data 1 Using the software T amp D Recorder for Windows which comes with the Data Collector TR 57DCi make necessary settings for infrared communication function and set to Permit For more details see the User s Manual that comes with the software 2 With the Unit and the TR 57DCi face to face and with about 5 to 20 cm of space between them download the recorded data from the TR 51i 52i to the TR 57DCi within 15 degrees from side to side and top to bottom For
15. r in the same manner as when you If dirt or scratches are present on the rubber packing water resistance will be reduced Please remove the dirt or replace the rubber packing if there re any cuts or scratches Be sure to completely close the cover Make sure not to over tighten the screws Notes about Battery Installation After inserting the battery it may occur that nothing appears in the display for about 10 seconds this is not a malfunction If a new battery has been installed and nothing appears in the display please remove and re insert the battery When inserting a battery make sure no water or foreign objects get inside the case Make sure that and are in the correct direction About Lithium Batteries LS14250 and CR2 Operating temperature range will vary depending on the battery If you are using in an environment below 20 C above 60 C or in a situation such as transportation where continued vibration is The lithium battery LS14250 is not sold in stores please purchase the Optional Battery Set TR 11P2 for replacement Please store the LS14250 in a place that is 20 C or less When changing a CR2 battery we strongly suggest changing the rubber packing and the drying agent In this case please purchase the Optional Maintenance Set TR 00P1 Appropriate torque 20N cm 30N cm 2Kgf cm 3Kgf cm likely to occur we suggest the use of the lithium batt
16. re exceeds the measurement range 60 C or below 155 C or above Sensor Unconnected for TR 52i only REC ows C This will be displayed when a sensor has not been connected or the wire has been broken Measurement and recording will continue so battery power will be consumed lf after re connecting the sensor and measurements can still not be displayed it is very possible that the sensor or the Unit are defective or have been damaged Communication with your Computer In order to change settings in the Unit such as recording settings download recorded data from the Unit to your computer or communicate with your computer it is necessary to purchase separately a Communication Port or Data Collector By using the Software T amp D Recorder for Windows supplied with the Communication Port or Data Collector it is possible to carry out communication with a PC For details about how to make recording settings download data and other operations please see the User s Manual that comes with the Communication Port or Data Collector The latest version of T amp D Recorder for Windows can be downloaded free of charge from our Web Site TR 51i and TR 52i can be operated with the Software version 1 80E or later Set up Procedure Recording Settings for the Unit 1 As instructed by the software connect the Communication Port or Data Collector to your computer using the provided communicatio
17. t in malfunction or unexpected accidents Store the Unit and accessories out of the reach of children Touching them may result in unexpected accidents Touching them may result in unexpected accidents If any smoke strange smells or sounds are emitted from the Unit immediately remove the battery and stop using Continued use may cause fire or electrocution Please be careful not to touch the Unit during or after use in overly hot or cold environments it may cause burns or frostbite A CAUTION We are not responsible for any damage malfunction or trouble whether direct or indirect caused by the use of the Unit Please be fully aware of this before using our product This Unit has been designed for private and or industrial use only It is not for use in situations where strict precautions are necessary such as in connection with medical equipment where directly or indirectly Battery life varies depending upon measuring environment frequency of communication Unit settings and battery performance The TR 52i becomes waterproof splash proof only after the temperature sensor has been connected Without the sensor connected neither the sensor jack of the Unit nor the connector part of the temperature sensor is waterproof make sure not to get wet Contact with oil may cause cracks to appear in the casing of the Unit When using the Unit in such an environment protect the Unit by placing it inside a polyethylene bag
18. ting Environment 1 The included Lithium Battery LS14250 is not sold in stores Please purchase the Optional Battery Set TR 11P2 for replacement 2 Battery life varies depending upon measuring environment frequency of communication Unit settings and battery performance Temperature Sensor TR 5106 Sensor Temperature Durability 70 to 180 C Thermal Time Constant In air about 15 sec In water about 2 sec Temperature Sensor TR 5106 Supplied with TR 52i 600 Waterproof ALM Warning LED D Optical Communication Area Infrared Port j Sensor Thermistor Fluoropolymer Coated Electrical Wire Specialized Connector E unit millimeters Make sure that the sensor is completely inserted until you hear a click sound The TR 52i only becomes splash proof when the sensor has been connected Thermo Recorder TR 51i 52i will be referred to as the Unit in this manual Installing the Battery Recording will start after the battery is inserted Screws Insert the attached Battery necessary opened it with tube 1 Remove the screws and open the cover Make sure to use the proper size and type of screwdriver Phillips head 1 screwdriver Do not remove the battery from its tube casing If using a CR2 lithium battery the tube is not Check the rubber packing condition and close the cove