EG600330 User Manual

image

Contents

1. Rotor Angle Rotor Tube Bank Rotor Rotating Speed mei 6500rpm Scope 1605 g 0 2ml Centrifugal 1936 g 0 5ml g g 2260 g Force 2230 g 1 5ml 2267 g 2ml Rotating wine Anticlockwise Direction p 4X8X0 2 ml PCR 8 tube bank Max Capacity 8X2 ml 1 5 ml or 16X0 2 ml single centrifugal tube Adapter 0 5 ml 0 2 ml Accelerating 3S Time Decelerating lt 28 Time Drive Mode DC24V direct drive with low noise attributable to rolling and Motor bearing Conversion from AC110 250V 50 60HZ to DV24V 48W Power Adapter with overload protection Voltage and Current Output DC24V2A from Power Adapter Voltage and Current Input to Power AC110 250V 50 60HZ Adapter Size 150WX160DX132Hmm Weight 1120g including free load angle rotor Compliance with the Standard Safety IEC61010 2 020 III Standard Configuration of the Machine 3 1 a One main machine of mini centrifuge see the figure below b One round rotor 8X2 1 5 ml see the figure below c One 4X0 2 ml rectangle rotor for PCR 8 tube bank see the figure below d One DC24V power adapter see the figure below e Eight 0 5 ml adapters and eight 0 2 ml adapters see the figure below f One copy of Instructions IV Instructions 4 1 Replacement or Installation of Rotor 4 1 1 When the machine is delivered from factory its seizing shaft sleeve and angle rotor are firmly
2. extragene web com Web Site www extragene web com 21
3. 4 2 The key on the seat may be pressed if the requirement of centrifugation is met then the lid will be automatically opened and immediately the speed of the rotor will decrease until zero 4 4 3 It is unnecessary to turn off power switch if another centrifugation is required 4 4 4 Plug of power adapter should be pulled out when all centrifugation work is completed V Special Attention Microtubes Rotor place the eight four or two microtube samples into the rotor symmetrically correct tube placement Tube strips Rotor place all two lines tubes into the rotor correct tube placement 11 GENERAL PRECAUTIONS the followings are general warnings and cautions concerning about the use of the centrifuge Observe these precautions strictly Warning Infectious Sample Aerosols This centrifuge is not equipped with a back up isolation system to contain aerosols in the event a tube leaks or breaks during a run If you suspect that exposure to aerosols from samples your handling could cause permanent or fetal illness do not put them in this centrifuge Warning NEVER centrifuge explosive or flammable substances Explosive or flammable items that ignite during a run will cause the centrifuge to explode This centrifuge does not provide adequart protection from explosions or fires originating in the chamber Do not overfill tubes Sample more than 70 percent full may leak during run This will expo
4. Instructions for EG 600330 Mini Centrifuge ExtraGene Inc Dear customers Thank you for selection of EG 600330 Mini Centrifuge You are kindly requested to carefully read the instructions before use Please install use and maintain the unit correctly according to the methods specified herein to ensure that the unit effects the best performance in a safe and comfortable manner Contents I Overview sooo0000000000000000000000000000000000000 L II Specifications of the Products o0000000000000000000000000 2 III Standard Configuration of the Machine o000000000000000 O IV Instructions 0000000000000000000000000000000000000009 V Special Attention scoooo0o0o000000000000000000000000000 11 VI Routine maintenance oo00000000000000000000000000000 25 I Overview 1 1 Name of the Product EG Mini Centrifuge 1 2 Model of the Product EG 600330 1 3 Features of the Product a Small and exquisite body one key operation b Convenient and quick installation and replacement of rotor without need of using tool c Rotor will immediately stop if lid is opened during operation d Desktop power adapter is applicable to 110 250V AC power supply e Elaborate product with low noise and long service time 1 4 Main Applications a Applicable to fast micro centrifugation and micro filtration b Applicable to the centrifugation for PCR tube bank c Especially suitable for use as a personal centrifuge II Specifications of the Product
5. fixed on the shaft of drive motor 4 1 2 If it is necessary to dismantle an installed rotor operators should hold the outside edge of rotor by hands and push and press the protruding clamp towards its center with two thumbs and slightly lift the rotor upwards 4 1 3 To reinstall rotor align the oval hole of rotor with the clamp press down the rotor and push the clamp hole blue towards the center with thumb and index finger of one hand meanwhile hold both ends of the rotor and press it down with the other hand The clamp is reset when a sound is heard See the figure below Bi 7 Angle Rotor 4 2 Power On 4 2 1 Connect the adapter supplied together with the unit with power source AC110 250V Connect the output end DC24V of the adapter with the power socket on the back of this machine 4 2 2 Press the ship formed power switch on the back of this machine towards OFF side with DC24V power source unconnected temporarily and then get ready for centrifugation 4 3 Preparation for Centrifugation 4 3 1 Open the transparent lid and properly add load in a balanced manner 4 3 2 Press the power switch on the back of this machine towards ON side and connect with DC24V working power supply The rotor will not run as long as the lid is opened 4 4 Centrifugation Running 4 4 1 After the lid is closed the rotor will automatically start running and increasing to the rated speed and then it will run stably 4
6. r than those specified by the manufacturer Substituted accessories or parts that do not meet the manufacturer s performance specifications may cause serious damage to the centrifuge or injure someone Do not unplug the centrifuge with pulling the power cord Stress to the cord may cause a loose connection in the plug and result in fire VI Routine maintenance Warning Never attempt to clean the centrifuge while it is plugged in or when the power is on If the device or accessories are contaminated by a pathogenic toxic or radioactive substance etc it is the user s responsibility to carry out appropriate decontamination while referring to the WHO Laboratory Biosafety Manual 2nd revised edition etc When cleaning and decontamination paying another mentioned more than this chapter are required contact our company to check whether they are likely to damage the device or not If you are planning to return the device or accessories to Our company or require repair you must contact our company before sending these items to us In some cases a certificate of implementation of cleaning and decontamination may be required before the items shipped to us Check and clean your centrifuge at regular intervals or immediately after spills occur to prevent premature wear and safety hazards 20 ExtraGene Inc Address 1424Yukon St Davis California 95616 TEL 530 753 2363 FAX 530 792 8352 E mail service
7. se to you and the centrifuge to sample aerosols that may make you ill or damage the centrifuge Use caps for tubes Tubes without caps will cause the sample leaking during the run This will expose to you and the centrifuge to 14 sample aerosols that may make you ill or may damage the centrifuge Warning Do not touch the power switch with wet hands You may sustain a serious or deadly electrical shock Do not use damaged or deformed rotors Rotors with compromised structures are subject to sudden and severe imbalances that will damage the centrifuge and may injure someone _ Be sure to balance the load properly Unbalance loads will significantly reduce the life of the motor and centrifuge In severe cases Unbalances may damage the centrifuge and injure the operator Do not open the lid until rotor stop completely Injury may occur from moving parts Do not replace the fuse other those specified by 16 the manufacturer That will damage the centrifuge and may injure someone Warning Do not touch the power plug with wet hands You may sustain a serious or deadly electrical shock Do not modify the centrifuge Modification to the centrifuge may cause a serious malfunction damage the centrifuge or cause injury to someone Unplug the power cord while not using Stress to the cord may cause a loose connection in the plug and result in a fire Do not use accessories of parts othe