Home

CONNECTOR CONVERSION BOX GT16H-CNB

image

Contents

1. communication connector RS 232 D Sub 9 pin male Connects to the external connection device via a GOT1000 series cable External connection RS 422 485 connector and RS 232 connector cannot device be used at the same time communication connector RS 422 485 D Sub 9 pin female External connection device communication connector Ethernet RJ 45 module jack Connects the external connection device via Ethernet with using a LAN cable 13 Rotary switch U Sets the ID number of GT16 CNB 42S Sets one ID number with using both rotary switches 14 Rotary switch L U and L Enables the recognition function of ID number ON Valid OFF Invalid When connecting the external connection device with using 10 and 11 set OFF invalid 16 Hole for the flange Used for fixing the flange when using the connector installation conversion adapter ID number valid 15 invalid selection switch 4 Installation The Connector Conversion Box can be installed on the panel face directly or on the DIN rail 4 1 Mounting on the panel face When setting the connector for Handy GOT connection and the power supply switch on the panel surface 1 Direct mounting on the panel face Drill a mounting slot of the following size on the panel face 77 0 5 3 04 40 02 Drill 4 6540 5 0 2 40 02 e a N _ oO D amp Z to 2 o O 2 T z g Lo oe co pe
2. CAUTION e Use the Connector Conversion Box within the generic environment specifications described in this manual If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur WIRING PRECAUTIONS WARNING e Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the Connector Conversion Box power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the Connector Conversion Box power supply section after confirming the rated voltage and terminal arrangement of the GOT Not doing so can cause a fire or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS CAUTION e Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS N WARNING e Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device
3. changing the word device current value changing the settings or current values of the timer or counter and changing the buffer memory current value read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS Z WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault e When unplugging the cable
4. connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION e The Connector Conversion Box is a precision instrument During transportation avoid impacts larger than those specified in this manual Failure to do so may cause failures in the unit After transportation verify the operations of the unit Certification of UL cUL standards UL cUL Standards are recognized in use by the following combination e GT1665HS VTBD Hardware version F or later e GT16H CNB 42S e External cable GT16H C30 42P GT16H C60 42P GT16H C100 42P General notes on power supply This equipment must be supplied by a UL Listed or Recognized 24 V dc rated power supply and UL Listed or Recognized fuse rated not higher than 4A or a UL Listed Class 2 power supply Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial appli
5. fix it with four M4 screws prepared by user In the Connector Conversion Box thread of M4 6mm 0 23 in depth is cut in each mounting hole Prepare four M4 mounting screws separately while considering the thickness of the panel face Tightening torque 0 69 to 0 88 Nem Make sure that interfering objects are not located within 65mm 2 56 from the rear face so that the connector of a PLC cable is not hindered To wire the terminal block keep a space of 25mm 0 98 or more on both sides of the Connector Conversion Box i 25 0 99 DPPPPPPPPE G000000000 25 0 99 Unit mm inch 4 2 Mounting on the panel face When installing the Connector Conversion Box on the panel surface 1 Mounting on the panel face Install the Connector Conversion Box on the panel face mounting surface Drill screw holes on the panel face as follows Tighten the mounting screw with the specified torque Tightening screws too much may cause damage Tightening torque 0 69 to 0 88 Nem M4 screw and nut x 4 sets f prepared by user 4 4 5 0 18 Unit mm inch 4 3 Installed on the DIN rail Install the Connector Conversion Box on the DIN rail DIN rail depth with using its DIN rail hook more than 10mm 0 4 inch Applicable DIN rail DIN46277 width 35mm 1 37 The clearance between screws for install the DIN rail should be 150mm 5
6. 9 or less 1 Pull out the hook for 2 Adapt the upper side of 3 Lock the hook for DIN rail the DIN rail installation slot to the DIN rail DIN rail while forcing the product on the DIN rail When installing the DIN rail please fix the cables Otherwise the hook for DIN rail and other parts may be damaged by the cable load This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured un
7. C When including the consumption current of Handy GOT Connector Conversion Box only 2 2W 90mA 24V When excluding the consumption current of Handy GOT Inrush current 25A or less at max load 2ms Permissible instantaneous power failure time Within 5ms Applicable GOTs Abbreviations Model name GT16 Handy GOT GT1655HS VTBD Specifications GOT 1000 Internal Relay Contact Specifications Item Contact rating 10mA 24VDC Each contact coordinates the operation switch status of Pressed close Not pressed open resistance load only When the external cable is not connected contacts are always open regardless of the switch status Operation switch SW1 to SW6 Each contact coordinates the emergency stop switch status of Pushed open Return close When the external cable is not connected contacts are always open regardless of the emergency stop switch status Causing a short circuit of the ESOB terminal which is close to the ESLA terminal by a short pin prepared by user enables to set each contact in the close status Emergency stop W 24VDC even if the external connection cable is not connected gt GT16 Handy GOT User s Manual switch ee When using the short circuited ESOB terminal which is close to the ESDA terminal ES1A to ES3A e Contacts are normally operated in the close status When pushing the emergency stop switch the contacts become open e In the following situations contacts are closed regardless of the stat
8. Connector Conversion Box is a precision instrument During transportation avoid impacts larger than those specified in this manual Failure to do so may cause failures in the unit After transportation verify the operations of the unit Certification of UL cUL standards UL cUL Standards are recognized in use by the following combination e GT1665HS VTBD Hardware version F or later e GT16H CNB 42S e External cable GT16H C30 42P GT16H C60 42P GT16H C100 42P General notes on power supply This equipment must be supplied by a UL Listed or Recognized 24 V dc rated power supply and UL Listed or Recognized fuse rated not higher than 4A or a UL Listed Class 2 power supply Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial applications e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical const
9. JY997D40401E MITSUBISHI ELECTRIC JAPANESE ENGLISH CONNECTOR CONVERSION BOX GT16H CNB 42S User s Manual GRAPHIC OPERATION TERMINAL Manual Number JY997D40401E This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration Ethernet is a registered trademark of Xerox Corporation in the United States MODBUS is a trademark of Schneider Electric SA The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2010 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as and A CAUTION s Indicates that incorrect handling may cause hazardou N WARNING conditions
10. Panel cut area 4 R3 max Panel opening Unit mm inch 61 1 0 2 41 0 04 0 Panel opening 3 Mounting on the panel face 2 Installation of the packing Install the accessory packing to the packing attachment chase of the Connector Conversion Box Be sure to install the packing Elevation view Packing attachment chase Fit the Connector Conversion Box from the back side of the panel face and fix it with four M4 screws prepared by user In the Connector Conversion Box thread of M4 6mm 0 23 in depth is cut in each mounting hole Prepare four M4 mounting screws separately while considering the thickness of the panel face Tightening torque 0 69 to 0 88 Nem Make sure that interfering objects are not located within 65mm 2 56 from the rear face so that the connector of a PLC cable is not hindered To wire the terminal block keep a space of 25mm 0 98 or more on both sides of the Connector Conversion Box 25 0 99 2000000000 808880089 Sree i 25 0 99 Unit mm inch 4 2 Mounting on the panel face When installing the Connector Conversion Box on the panel surface 1 Mounting on the panel face Install the Connector Conversion Box on the panel face mounting surface Drill screw holes on the panel face as follows Tighten the mounting screw with the specified torque Tightening screws too much may cause damage Tightening torque 0 69 to 0 88 Ne
11. TP e PLC manufactured by other company microcomputer temperature controller inverter servo amplifier CNC MODBUS R RTU or MODBUS R TCP connection Produce the cable RS 232 cable RS 422 485 cable for connecting the GOT to a controller with reference to the following manual GOT1000 Series Connection Manual for GT Works3 and a controller used 3 General notes on Power supply The Connector Conversion Box requires an additional ferrite filter to be attached to the 24V DC power supply cables The filter should be attached in a similar manner as shown in the figure opposite i e the power cables are wrapped around the filter However as with all EMC situations the more correctly applied precautions the better the systems Electro magnetic Compatibility The ferrite recommended is a TDK ZCAT3035 1330 or similar The ferrite should be placed as near to the 24V DC terminals of the Connector Conversion Box as possible which should be within 75mm of the GOT terminal Up to 75mm 2 95inch Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Contents Manual Number Model Code GT16 Handy GOT User s Describes the Handy GOT hardware Manual name Manual relevant content such as part names JY997D41201 Hardware Utility external dimensions mounting power JY997D41202 Connection supply wiring specif
12. actured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
13. als introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as and A CAUTION s Indicates that incorrect handling may cause hazardou N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS WARNING e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction e f a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction e Do not use the GOT
14. as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction e Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out the POWER LED flickers green orange and the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The POWER LED flickers green orange and the monitor screen appears blank DESIGN PRECAUTIONS CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING PRECAUTIONS WARNING e Make sure to turn off the Connector Conversion Box s power before attaching or detaching it to from the GOT Failure to do so may cause unit failure or malfunctions MOUNTING PRECAUTIONS
15. black corrosive gas flammable gas or Operating excessive amount of electroconductive dust particles and must be no atmosphere direct sunlight Same as for saving Power Supply Specifications Item Input power supply voltage Power consumption Connector Conversion Box only Inrush current Permissible instantaneous power failure time Applicable GOTs Abbreviations GOT 1000 Internal Relay Contact Specifications Item Contact rating 10mA 24VDC resistance load only Operation switch SW1 to SW6 Emergency sto iea Bak y stop resistance load 0 3A 24VDC ES1A to ES3A induction load 1A 24VDC Grip switch resistance load DSW1 DSW2 0 3A 24VDC induction load Keylock switch 1A 24VDC 2 position switch resistance load KSWC KSW1 0 3A 24VDC KSW2 induction load Within 5ms Specifications 24VDC 10 15 13 7W or less 570mMA 24VDC When including the consumption current of Handy GOT 2 2W 90mA 24V When excluding the consumption current of Handy GOT 25A or less at max load 2ms Model name GT16 Handy GOT GT1655HS VTBD Specifications Each contact coordinates the operation switch status of Pressed close Not pressed open When the external cable is not connected contacts are always open regardless of the switch status Each contact coordinates the emergency stop switch status of Pushed open Return close When the external cable is not connected contacts are always open regardless
16. by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the Connector Conversion Box power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the Connector Conversion Box power supply section after confirming the rated voltage and terminal arrangement of the GOT Not doing so can cause a fire or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS CAUTION e Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS NWARNING e Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter and changing the buffer memory current value read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform signifi
17. cant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS Z WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault e When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION e The
18. cations e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark Compliance with all relevant aspects of the ev standard Radiated Emissions EN61131 2 2007 Programmable controllers Equipment requirement and tests EMS Compliance with all relevant aspects of the standard ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site Notes for compliance to EMC regulation 1 General notes on the control panel Make sure to combine the GT16 Handy GOT with the Connector Conversion Box to comply with the EMC directive The Connector Conversion Box is an open type device device installed to another device and must be installed in a conductive control panel 2 General notes on the use of communication cables e External cable GT16H C30 42P GT16H C60 42P GT16H C100 42P e Direct connection cable User Made Cables Th
19. der strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JY997D40401E MITSUBISHI ELECTRIC JAPANESE ENGLISH CONNECTOR CONVERSION BOX GT16H CNB 42S User s Manual Manual Number JY997D40401E GRAPHIC OPERATION TERMINAL GOTicoo This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration Ethernet is a registered trademark of Xerox Corporation in the United States MODBUS is a trademark of Schneider Electric SA The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2010 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manu
20. described below e Terminal block cover opened 110 4 34 e External cable connected 56 2 21 55 2 17 T 126 4 97 Lesernes 65 2 56 6 7 about 130 5 12 Space required for connecting the cable Unit mm inch Weight about 0 5kg Specifications Connector for Handy 1 GOT 42 pin female Supplies the power to the Handy GOT 2 Power switch When this switch is set to ON the power is supplied Turn off the power when attaching or detaching the Handy GOT 3 POWER LED Lit in green Power is correctly supplied Not lit Power is not supplied 4 Hole for the panel Used when mounting the panel For M4 screw depth installation 6mm 5 Packing otaciment Used when mounting the panel chase 6 Hook for DIN rail Used for fixing the Connector Conversion Box when mounting DIN rail 35mm Connects a Handy GOT through an external connection cable No Specifications 7 Hole for the Screw Used for fixing on the board etc For M4 screw installation Connects the GT16H CNB 42S the 24VDC power supply of Handy GOT and the emergency stop switch ES 1 to 3 with M3 terminal screw and the cover Terminal block 1 Connects the operation switch of the Handy GOT SW1 to 6 the grip switch DSW 1 2 and the keylock switch KSW 1 2 with M3 terminal and the cover Terminal block 2 External connection device
21. e cable need to be independently tested by the user to GT01 C30R4 8P demonstrate EMC compatibility when they are used with GT11H C30R2 6P the GOT the PLC of MELSEC Q series MELSEC L series MELSEC QnA MELSEC A series and MELSEC FX series Existing Cables e Ethernet connection cable Shielded twisted pair cable STP e PLC manufactured by other company microcomputer temperature controller inverter servo amplifier CNC MODBUS R RTU or MODBUS R TCP connection Produce the cable RS 232 cable RS 422 485 cable for connecting the GOT to a controller with reference to the following manual GOT1000 Series Connection Manual for GT Works3 and a controller used 3 General notes on Power supply The Connector Conversion Box requires an additional ferrite filter to be attached to the 24V DC power supply cables The filter should be attached in a similar manner as shown in the figure opposite i e the power cables are wrapped around the filter However as with all EMC situations the more correctly applied precautions the better the systems Electro magnetic Compatibility The ferrite recommended is a TDK ZCAT3035 1330 or similar The ferrite should be placed as near to the 24V DC terminals of the Connector Conversion Box as possible which should be within 75mm of the GOT terminal Up to 75mm 2 95inch Associated Manuals The following manuals are relevant to this product When these loose manuals are requir
22. ed please consult with our local distributor Contents Manual Number Model Code Manual name GT16 Handy GOT User s Describes the Handy GOT hardware Manual relevant content such as part names JY997D41201 Hardware Utility external dimensions mounting power JY997D41202 Connection supply wiring specifications and 09R821 1 2 2 2 introduction to option devices sold separately For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Bundled item Quantity GT16H CNB 42S Connector conversion box 1 Packing for panel installation 1 Flange for GT10 9PT5S 1 Screws for flange installation M3x8 2 CONNECTOR CONVERSION BOX GT16H CNB 42S User s Manual This manual 1 Features The Connector Conversion Box relays the GOT s external 42 pin connector to the power supply switch and the PLC s connector and terminal block while enabling users to operate the Handy GOT outside the enclosure Handy GOT Control panel or T operation panel GT16H CNB 42S Connector Conversion Box External cable GT16H c OO 42P Option 2 Specifications General Specifications Other specifications are the same as the GT16 Handy GOT main unit Item Specifications Operating ambient 0 to 55 C temperature Storage ambient 20 to 70 C temperature Half Sweep T e When resistance DIN rail each in X Y 9 to 150Hz 4 9m s2 a directions f Must be free of lamp
23. for the panel Used when mounting the panel For M4 screw depth installation emma 16 Hole for the flange Used for fixing the flange when using the connector installation i conversion adapter 5 Packing attachment Used when mounting the panel chase 6 Hook for DIN rail Used for fixing the Connector Conversion Box when mounting DIN rail 35mm Connects a Handy GOT through an external connection cable Sets the ID number of GT16 CNB 42S Sets one ID number with using both rotary switches U and L 4 Installation The Connector Conversion Box can be installed on the panel face directly or on the DIN rail 4 1 Mounting on the panel face When setting the connector for Handy GOT connection and the power supply switch on the panel surface 1 Direct mounting on the panel face Drill a mounting slot of the following size on the panel face 7740 5 3 04 40 02 Drill 4 6540 5 0 2 0 02 g I x N A oO I D amp iH T o Q 2 a cy T el a Lo I 1 Go Panel cut area 4 R3 max Panel opening Unit mm inch 61 1 0 2 41 0 04 0 Panel opening 3 Mounting on the panel face 2 Installation of the packing Install the accessory packing to the packing attachment chase of the Connector Conversion Box Be sure to install the packing Elevation view Packing attachment chase Fit the Connector Conversion Box from the back side of the panel face and
24. ications and 09R821 1 2 2 2 introduction to option devices sold separately For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Bundled item Quantity GT16H CNB 42S Connector conversion box 1 Packing for panel installation 1 Flange for GT10 9PT5S 1 Screws for flange installation M3x8 2 CONNECTOR CONVERSION BOX GT16H CNB 42S User s Manual This manual 1 Features The Connector Conversion Box relays the GOT s external 42 pin connector to the power supply switch and the PLC s connector and terminal block while enabling users to operate the Handy GOT outside the enclosure Handy GOT Ea Control panel or operation panel GT16H CNB 42S Connector Conversion Box External cable GT16H CLILILI 42P Option 2 Specifications General Specifications Other specifications are the same as the GT16 Handy GOT main unit Item Specifications Operating ambient 0 to 55 C temperature Storage ambient 20 to 70 C temperature Half Sweep T e When resistance DIN rail eachinX Y 9 to 150Hz 4 9m s2 anda directions 3 Must be free of lamp black corrosive gas flammable gas or Operating excessive amount of electroconductive dust particles and must be no atmosphere direct sunlight Same as for saving Power Supply Specifications Item Specifications Input power supply voltage 24VDC 10 15 Power consumption 13 7W or less 570mA 24VD
25. m M4 screw and nut x 4 sets t prepared by user 4 64 5 0 18 S Unit mm inch 4 3 Installed on the DIN rail Install the Connector Conversion Box on the DIN rail j DIN rail depth with using its DIN rail hook more than 10mm 0 4 inch Applicable DIN rail DIN46277 width 35mm 1 37 The clearance between screws for install the DIN rail should be 150mm 5 9 or less 1 Pull out the hook for DIN rail 2 Adapt the upper side of 3 Lock the hook for DIN rail the DIN rail installation slot to the DIN rail while forcing the product on the DIN rail When installing the DIN rail please fix the cables Otherwise the hook for DIN rail and other parts may be damaged by the cable load This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manuf
26. of the emergency stop switch status Causing a short circuit of the ESOB terminal which is close to the ESLA terminal by a short pin prepared by user enables to set each contact in the close status even if the external connection cable is not connected GT16 Handy GOT User s Manual When using the short circuited ESOB terminal which is close to the ESLA terminal e Contacts are normally operated in the close status When pushing the emergency stop switch the contacts become open e In the following situations contacts are closed regardless of the status of the emergency stop switch and the external cable When GT16H CNB 42S is turned OFF When GT16H CNB 42S is not supplied with the power supply DC24V Each contact coordinates the grip switch status of Pressed close Not pressed open When the external cable is not connected contacts are always open regardless of the grip switch status Each contact coordinates the position of the keylock switch e When the key is on the left KSW1 and KSWC are short circuited e When the key is on the right KSW2 and KSWC are short circuited When the external cable is not connected contacts are always open regardless of the keylock switch The system may not match the safety standards Before using the system please check the safety standards which are required 3 Part Names and External Dimensions The name and the external dimensions of each part of the Connector Conversion Box are
27. resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS WARNING e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction e f a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction e Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction e Incorrect operation of the
28. ruction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark Compliance with all relevant aspects of the ev standard Radiated Emissions EN61131 2 2007 Programmable controllers Equipment requirement and tests EMS Compliance with all relevant aspects of the standard ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site Notes for compliance to EMC regulation 1 General notes on the control panel Make sure to combine the GT16 Handy GOT with the Connector Conversion Box to comply with the EMC directive The Connector Conversion Box is an open type device device installed to another device and must be installed in a conductive control panel 2 General notes on the use of communication cables e External cable GT16H C30 42P GT16H C60 42P GT16H C100 42P e Direct connection cable User Made Cables The cable need to be independently tested by the user to GT01 C30R4 8P demonstrate EMC compatibility when they are used with GT11H C30R2 6P the GOT the PLC of MELSEC Q series MELSEC LL series MELSEC QnA MELSEC A series and MELSEC FX series Existing Cables e Ethernet connection cable Shielded twisted pair cable S
29. touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out the POWER LED flickers green orange and the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The POWER LED flickers green orange and the monitor screen appears blank DESIGN PRECAUTIONS CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING PRECAUTIONS WARNING e Make sure to turn off the Connector Conversion Box s power before attaching or detaching it to from the GOT Failure to do so may cause unit failure or malfunctions MOUNTING PRECAUTIONS CAUTION e Use the Connector Conversion Box within the generic environment specifications described in this manual If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur WIRING PRECAUTIONS WARNING e Be sure to shut off all phases of the external power supply used
30. us of the emergency stop switch and the external cable When GT16H CNB 42S is turned OFF When GT16H CNB 42S is not supplied with the power supply DC24V induction load 1A 24VDC Grip switch resistance load Each contact coordinates the grip switch status of Pressed close Not pressed open DSW1 DSW2 0 3A 24VDC When the external cable is not connected contacts are always open regardless of the grip switch status induction load Each contact coordinates the position of the keylock switch e When the key is on the left KSW1 and KSWC are short circuited e When the key is on the right KSW2 and KSWC are short circuited When the external cable is not connected contacts are always open regardless of the keylock switch Keylock switch 1A 24VDC 2 position switch resistance load KSWC KSW1 0 3A 24VDC KSW2 induction load 1 The system may not match the safety standards Before using the system please check the safety standards which are required 3 Part Names and External Dimensions No Specifications The name and the external dimensions of each part of the Connector Conversion Box are described below 7 Pole tor the S Go iced for fixing on the board etc For M4 screw i installation External cable Terminal block connected cover opened 56 2 21 55 2 17 110 4 34 Connects the GT16H CNB 42S the 24VDC power supply of Handy GOT and the emergency stop switch ES 1 to 3 with M3 terminal scre
31. w and the cover 8 Terminal block 1 Connects the operation switch of the Handy GOT SW1 to 6 the grip switch DSW 1 2 and the keylock switch KSW 1 2 with M3 terminal and the cover Terminal block 2 126 4 97 External connection MA i O04 9008 device Ae communication 5 2 56 i connector RS 232 9 D Sub 9 pin male Connects to the external connection device via a GOT1000 series cable External connection RS 422 485 connector and RS 232 connector cannot device be used at the same time communication connector RS 422 485 D Sub 9 pin female about 130 5 12 Space required for connecting the cable Unit mm inch Weight about 0 5kg Specifications External connection device i Connects the external connection device via Ethernet communication with using a LAN cable Connector for Handy 1 ie aa connector Ethernet emale RJ 45 module jack Supplies the power to the Handy GOT When this switch is set to ON the power is supplied 1S Roly switchi U 2 Power switch i Turn off the power when attaching or detaching the 14 Rotary switch L Handy GOT ID number valid Enables the recognition function of ID number 3 POWER LED i a Pana is correctly supplied Not lit aa eon ON Valid OFF Invalid Sere Or SURMISE When connecting the external connection device with using 10 and 11 set OFF invalid switch 4 Hole