Home
Mistral MAX2 EN user - Ray Service On Site
Contents
1. 8 seconds press the valet switch 5 times default code d After 5 seconds siren will chirp 4 times to confirm that system is disarmed e Turn the ignition OFF installation of car alarm Follow the steps below to change default code a When the system is disarmed turn the ignition ON b Within 8 seconds press the valet switch 9 times c Siren will chirp 4 times d Press valet switch according to your new code 1 9 Each pressing the button is confirmed by LED flash e After 8 seconds siren will chirp several times Number of chirps is corresponding to the number of new code f Turn the ignition OFF Valet mode The only feature operating in valet mode is the keyless entry function Valet mode is useful when leaving your car in service To enter valet mode follow this procedure a When the system is disarmed turn the ignition ON b Within 8 seconds press the valet switch 3 times c Siren will chirp once and the LED will be constantly on d Turn the ignition OFF During the valet mode car is not protected and immobilized by alarm
2. Ai MISTRAL MAX CAR ALARM WITH HOPPING CODE USER MANUAL SYSTEM DESCRIPTION central locking outputs and trunk released output too I DESCRIPTION OF REMOTE CONTROLLER Remote controller function Arm and Lock Il SYSTEM OPERATION INDICATION BY STATUS LED The status LED can indicated following condition of system Quickly flashing f Alarm is triggered Auto rearming countdown Last door arming countdown System disarming Nesvieti ARMING Condition Disarmed a Press the button e b Siren will chirp once optional setting and lights will flash once c Doors will lock immobilization circuit start kill output will activate d LED will flash slowly to confirm the system is armed If any door is open during arming the siren chirps 5 times but the system will be armed anyway Sensor Temporary Bypass The sensors can be bypassed temporarily until the next arming of the system operations are as follows a Press the button A io arm the system b Within 3 sec press button SS The sensors has been bypassed DISARMING The MISTRAL MAX is a car alarm designed for vehicles with 12 V supply voltage and is used to Condition Armed monitor the doors trunk hood ignition switch and security loop In case of their disruption system is reporting alarm by optical and audible siren signalling The system includes shock sensor with adjustable sensitivity that in case of impact of vehicle reacts with alarm Wh
3. ated LED will be flashing quickly for 30 seconds or until opening the door 2 times Siren sounding up to 30 seconds If any of sensors is constantly triggering the alarm can be automatically bypassed after determined number of alarms caused by this sensor This sensor will be inactivated while all other sensors remain active If there will be alarm triggered by any other sensor inactivated sensor will automatically activate again Number of maximum consequent alarms triggered by one sensor is setin option 4 gion SS LED flashes 7 times Additional sensor LED flashes 8 times LED flashes 9 times Bo press the buttons Qo simultaneously for 3 seconds countdown will be cancelled After this arming is possible only manually by pressing the button Ml AUTOMATIC REARMING If within 30 seconds after disarming are not opened any door trunk or ignition switched on systems will automatically arm again This function is optional feature 17 CAR FINDER Can be used to find your car on the parking place PAGER OUTPUT When alarm is triggered pager output is activated at the same time This output can be used for long distance pager GSM pager or any other device Ill SYSTEM INSTALLATION Learning code of transmitter It is possible to program up to 4 transmitters into the system Follow the procedure below to program a new transmitter to the system Please note that during programming mode a
4. code for emergency disarming will reset If you use the remote trunk release and pressing button amp the system monitors the trunk fe cs l ae Default code for emergency disarming is 5 We recommend you to change this code after the or door contact but the countdown shall be interrupted until you open the trunk Activation of the AUX outputs will not reset countdown of arming 2 By pressing the button 2 Loud When system is armed press the button Siren will chirp 5 times and lights will flash 10 times DOOR OPEN WARNING When the ignition is turned ON and the system is disarmed the lights will flash 10 times to alert when door or trunk is opened This function is optional feature 18 2 REMOTE TRUNK RELEASE To activate remote trunk release press the button for 3 seconds The duration of the output trunk a here To exit valet mode repeat the same procedure is optional feature 12 You can choose also whether using of remote trunk release cause disarming the system at the same time or not feature 16 REMOTE AUX1 ACTIVATION 2 To activate additional output AUX1 press the buttons mf ond Ls simultaneously or press the button 2 AUX Duration of AUX1 impulse can be set feature 13 a Press the button uf b Siren will chirp 3 times optional setting and lights will flash 3 times c Doors will unlock and immobilization circuit turns off d When Auto rearming function is activ
5. en car alarm is acti vated the system automatically blocks the starter circuit The car alarm includes two AUX output ALARM If during arming mode is car attacked siren will go off lights will flash and pager output will be activated You can select from 4 different types of siren sound to differentiate your car from the others feature 5 To stop the sound of siren press any button on remote controller The systems will remain armed To disarm system during alarm press the button LED DIODE SIGNALISATION AFTER TRIGGERED ALARM When disarming if siren chirps 5 times first one is longer it means that during your absence alarm has been activated After opening the door LED will inform you by number of flashes reason of alerts see table LED will stop flashing after ignition will be turned ON LED flashes 4 times LED flashes 5 times LED flashes 6 times PANIC This function will activate alarm anytime needed Activation Press the button Deactivation Press any button Note When systems disarmed door is locked and immobilization circuit turned on too LAST DOOR ARMING If ignition is turned OFF and the door is opened and closed system will enter arming mode automati i l i To exit from the emergency mode press any button of transmitter cally after predetermined time feature 7 If during this period door or trunk is opened countdown A D i Changing the
6. ll present remotes will be deleted from memory Follow next procedure a When the system is disarmed turn the ignition ON b Within 8 seconds press the valet switch 5 times c Siren will chirp 2 times you have entered the programming mode d Within 8 seconds press any button on first transmitter e Siren will chirp once lights flash once to confirm that first transmitter has been programmed to the system f The siren will chirp the number equal to number of learned transmitter g After programming of last transmitter Turn OFF the ignition All remote controllers you wish to use must be programmed at the same time If there was no remote programmed old remotes will stay in system memory In case that remote controller is lost and you want to avoid its abusing by someone who will find it erase all programmed remotes from alarm memory To do it follow this procedure a When the system is disarmed turn the ignition ON b Within 8 seconds press the valet switch 5 times c Within 8 seconds turn the ignition OFF d All transmitters will be erased from the memory and system will enter valet mode For programming new transmitter must exit valet mode at first Emergency disarming If the transmitter becomes lost or non functional the system can still be disarmed by following procedure a System is armed or alarm is triggered siren sounds b Enter the car and turn the ignition ON c Within