Home

808nm Diode Laser

image

Contents

1. Handle Piece Model HP Wavelengh 808nm 940 Max Energy Fluence 120 150J Sapphire Window Dimension 16x10mm Typical Fluence 50ms 10Hz 60J cm2 Typical Fluence 50ms 15Hz 90J cm2 Peltier TEC Operation 7 5V 15A Min Flow Rate Requirement 3 0L min Ill POWER SUPPLY CONTROL SOFTWARE AND FULL SYSTEM oo NDL also provides electronic products for the laser stacks and handle piece including power supply laser diode driver MCU based control board LCD and software for OEM ODM clients Laser Diode Driver 1 Provide constant current control for laser pulses with excellent pulse shape 2 Designed with analog modulation and external control interface 3 High efficiency without extra cooling 4 MCU Control Board 1 2 Control peltier cooler to reach 5 C 5 C for Skin Cooling Designed with laser diode protection circuits for safe operation Control laser diode driver pump fans and all the other parts of the system 2 Communication with LCD screen LCD amp Software 1 Provide simple amp easy user control interface with touch screen Basic Notice 1 These products are designed for OEM manufacturers or distributors for easy system integration 2 Most of these spare parts are 3C qualified 12 Treatment Notice 1 The treatment of the hair removal needs experienced professionals Do not use it if you have no experience for such kind of laser device 2 Operators and patients m
2. Warning Injury may occur when the following instructions are not followed Always keep the hand piece in contact with the skin when the beam iS on Do not beam direct on to unshielded eyes Do not use the unit to eyes or eyelids The unit is not to be used by children or persons with reduced physical sensory or mental capabilities or lack of en and knowlege unless they have been given instruction Restriction Refrain from administering if the person or the Area to be treated is affected by one of the following conditions E Y D A person whose activity was outdoors under strong sunlight or who has received tanning treatment within the last 4 weeks A person whose skin color is black or dark brown should use lower energy and parameters P N O NG Pregnant women or the Do not use to this area during the breast feeding period Skin area with tattoos S Skin affected by diabetes or other skin diseases Laser type Laser wavelength Power Density Spot size Pulse width Energy Frequency Cooling Temperature of probe Working environment Environment temperature Relative humidity Atmospheric pressure Working Voltage Transportation and store Environment temperature Relative humidity Atmospheric pressure Size N Weight Voltage Packing _Features Diode laser 808 nm 1500W 10 4 inch color touch LCD screen 10 12 mm 10 1 400 ms adjustable 1 120 J
3. 4 The Treatment head can t light on a The head is broken b The controller is broken c The Power line is broken Solution Contact us directly 5 No Flashing a Do not contro well of the switch on the treatment head b Make the wrong operation c The controller is broken d The power line is broken e Need to change a new treatment head Solution Contact us directly 15
4. check if your wall plug and VAC voltage is in good conditions Or contact us for solutions Laser Diode Temperature Laser diode temperature is too high sore NA system Electrical Schema V2 1 Date 2012 05 01 L WN WAC Input 220 110 LCD EHH Air Switch Handle Piece Pe e e e e U u ia MeanvVell I o NES 50 12 l Laser CO L 1 System Control l Diode _ amp la C Relays Control Signal l l TEC Meanwell BE ae SE 600 12 SS Laser Diode EW MeanvVell F Pedal Switch NES 150 7 5 EJ eae Flow Sensor Protection 150 1 I H Fanse HHH Pump External Protections Fan Sr ea l Malfunction and solutions 1 No power supply a Check up whether there is power sup b Check up whether the power line is connected well c Check up the fuse which could be pulled out at the bottom of hole for power plug d Check up if you open the key switch and emergency switch Solution a connect well the power line b change the fuse c open the key switch and release the emergency switch button 2 Non Refrigeration after opening the machine a cooling electric source is broken b Semiconductor is broken c there s air in the treatment head non well water circulation Solution Contact us directly 3 Treatment Head leakage a the srews of the head loose b the water pipe inner of the head has dropped down c lamp or crystal of the head is broken Solution Contact us directly
5. 808nm Diode Laser USER MANUAL Please read this manual carefully before operating this machine Keep it for future reference iN Danger The following instructions contain important safety information which may lead to death or critical injury if not followed Daring Injury may occur when the following instructions are not followed 9 nectriction Refrain from administering if the person or the ea to be treated is affected by one of the following condition Danger The following instructions contain important safety information which may lead to death or critical injury if not followed dh Be sure to keep the metal pins of the power plug free from dust or moisture When cleaning use a cloth cleaner Using multiple products on a single outlet is not recommended aS ne Keep the unit and the power plug away from heaters or stoves Do not pull the power plug by force or with wet hands Neither bending the power cord nor placing heavy objects on the power plug is recommended The unit is not designed for cleaning with water Always clean with a dry cloth cleaner before storing the unit Do not operate the product in elevated or wet places Ensure that the unit is turned off when connecting or disconnecting the power plug Do not leave the unit connected to the power when not in use over a long period of time Disconnect from the power supply when cleaning the unit
6. ODE CHIPS AND LASER STACKS ll HAIR REMOVAL HANDLE PIECE ASSEMBLY 10 lll LASER DIODE CHIPS AND LASER STACKS FOR HAIR REMOVAL Based on MICRO CHANNEL COOLER package NDL provides high power laser diode bars arrays and stacks from 780nm 808nm 915nm 940nm 980nm up to 1060nm This infrared wavelength is proved to be the best wavelength for hair removal treatments especially for 808nm 810nm Most of the hair removal systems are now choosing laser powers from 200W up to 1000W or more such as 240W for Aroma 600W for Alma Laser Soprano 1600W 2900W for Lumenis LightSheer and etc 1 Typical Laser Diode Bar Parameters omaron we o o Slow Axis Divergence FWHM Operating Current Laser Bar Typer 60W BAR 80W BARe Operating Voltage Pn ra Pthvesholscunent av e e aa we Power Conversion Efficiency Operating Temperature 2 Typical laser diode stacks for hair removal fee ess a cosas stad wa Danza wat Stack Type 3x60W STACK 6x60W STACK 10X60W STACK 12x60W STACK Optical Power 180W 360W 600W 720W Operation Voltage lt 6V lt 12V lt 20V lt 24V Notice 1 This product is for professional equipment manufacturers only The client must have long experience on laser diodes operation maintenance cooling packaging protection and etc 11 ll HAIR REMOVAL HANDLE PIECE ASSEMBLY Standard Handle Piece Model
7. The laser output power should be calibrated each year Normal Laser Power Meter Calibration should be used and personnel should have appropriate qualifications 8 4 Fuse Replacement Cut off the power unplug the power cord before proceeding with the replacement fuse Replacement screw with a screwdriver under the fuse to install seat remove the waste fuse install a new fuse fuse installed to install and tighten the seat and pay attention to the appropriate fuse size should be consistent with the nameplate DIODE LASER HAIR REMOVAL BEST OEM SOLUTIONS WE KNOW LASER DIODES BETTER 1 Weare professional laser diode manufacturer with 5 years experience 2 Wework on high power laser diode chips and laser diode stacks only 3 We have more experience on micro channel laser stacks maintenance WE DELIVER QUALIFIED TECHNICAL PARAMETERS 1 We deliver full pulse energy as requested even up gt 150J cm2 is possible 2 We always focus on the improvement for skin cooling Now we can reach 5 C 5 C for skin cooling 3 We never stop the technical improvements on diode chips structure designs electronics and software WE PROVIDE OEM amp ODM SOLUTIONS FROM LASER DIODES TO FULL SYSTEM 1 We provide laser sources from laser diode chips laser stacks to handle piece 2 We provide electronic parts from laser diode drivers control board to LCD software 3 We provide standard OEM systems and also custom products I LASER DI
8. cm adjustable 0 5 10Hz Water air Semiconductor 2 3C 5 40 C lt 80 860hpa 1060hpa 220V 10 50HZ 20 60 C lt 100 500hpa 1060hpa 59 64 113 cm 62kg 220V 110V 15A 50Hz 60Hz Aluminum alloy case 3 The only system to provide permanent hair reduction using state of the art high power diode technology 4 Adopts 808nm Golden Standard wavelength which is particularly absorption by the pigmentation in hair follicles without injury to surrounding tissue thus remove the hair permanently 5 Perfect combination of long pulse duration and sapphire contact cooling promise more power given onto the skin to remove hairs of all skin types without injury of epidermis 6 Well worked contact cooling system provide comfortable safe and efficient treatment procedure 7 High power system removes hair of any colors and on anywhere 8 20X12mm _ is the maximum size for effective usage of the diode laser thus the given energy could be effectively worked on the treatment and let the patient enjoy the hair removal procedure just like shaver moves on body 9 The pure imported Diode Laser Palladium Bar promises to output big power and Stability of the whole machine 10 Rapid non invasive treatment that is and entails virtually no patient downtime 11 Except the cooling in the handle we also add special cooler in the water case in the machine and this water case was wrapped with cotton of constant temperature thus this mac
9. ctions for the operation of the machine and handle piece and notice that following situations can not be warranted 1 Operation the system without water 2 Power up the system without connecting the handle piece 3 Regular drops of the handle piece 4 Wrong input VAC 5 Other manual operating mistakes Status Error 01 12 This means the system protections take action You need to check if anything goes wrong with the system or environment The error code is as follows fot NA ere NA Room Temperature Low The room temperature is lt 5 C This may cause icing Error 05 Water Temperature High Water temperature gt 35 C Please check if the room temperature is gt 28 C The room must be with air conditioner Or it may cause cooling problem for the laser If this ERROR happens you need to move it to a room 13 lt 28 C Re start the machine and press ready and do not shoot the laser The system fan and pump will work for 10 minutes to cool down the water After the water is cooled down the ERROR should disappear Water Level Alarm The water tank is not fully filled PCB Temperature High PCB is too high Error 08 Flow Rate Protection The water flow for the handle piece is not enough Check if you bend the tube too much or the water connection of the handle piece is not well done Or there is not enough water in the water tank Error 10 Over Current Protection Over current protection for the laser diode Please
10. hine could permit long time working Application Range For fast safe painless and permanent hair removal on all 6 skin types including dark skin Suitable for any unwanted hairs on areas like face arms armpits chest back bikini legs upnair Amoi E 1 nn Bikini hair n A p v gt gt Arm hai I Bachhar A e Leg hair 3 Fill cooling water A Inject water Twist open the water inlet and air outlet nut water goes through the funnel from the water inlet hole to join until the overflow by water overfull Tighten the two nuts B Off watering used in exceptional circumstances Draining the water outlet and air outlet nut the water will flow from the drainage port And then wait for the water shorting the two holes of the nut tightening Check input Voltage Before connectiong to the power please check whether the input voltage of machine accord to power supply voltage see nameplate unanimously to avoid unnecessary risk Connect power supply cord The corresponding one end of the power cord into the machine power outlet plug the other end of network power supply output Note Net power supply must have a good grounding is recommended grounding of medical grade Connecting foot switch The power cord of the foot switch connect to the corresponding socket when the hear the pop and click sound that indicated that they had a normal connection Sa
11. lon Diode Laser Hair Removal System System Initializing DIODE MEDIC FREQUENCY Jicm2 STATUS Setting 4 cO 307 aoe 000 009 gt Attentions 7 1 Direct laser irradiation at any time does not allow people s eyes or the health of the skin 7 2 In order to prevent the human eye or skin subject to laser radiation do not allow laser to smooth the surface so as to avoid the formation of reflection or diffuse reflection of laser such as stainless steel surface mirror and so on 7 3 Equipment associated components with 75 alcohol cleaned and disinfected you must complete evaporation of alcohol etc only after the use of laser in order to avoid fire or explosion Using this instrument we must avoid the use of flammable anesthetics or oxidizing gases such as nitrous oxide N2O and oxygen 7 4 Segment position in order to prevent contamination of the focusing lens but also to ensure a clean surgical environment the proposed smoking device used in an operation Segment and focusing lens cleaner at least once every 3 months 7 5 During operation within 35m range area look directly at laser will damage the eyes Equipment operator must be at work wearing protective glasses 7 6 There will be high pressure inside of equipment Non professional staff is strictly prohibited to open instrument chasis so as to avoid an electric shock 7 7 Once the machines emit abnormal smell or produce an abnormal sound should i
12. mmediately cut off the power unplug the power cord to inspect before troubleshooting before the ban electricity Laser tube is made from glass be careful operation to avoid damage 7 8 The temperature range under normal operation 5 C 30 C humidity 10 80 7 9 To prevent the laser tube wall above water to ice Frost Crack empty the water of tank before removing equipment 7 10 Equipment parts and components on the end of life do not arbitrarily discard please follow the relevant laws and regulations to local environmental protection departments for processing 7 11 Equipment when not in use to pull out the key to lock switch and the key kept by specialized personnel 7 12 The operating room should be equipped with dust or smoke device to prevent dust pollution emissions from biological tissue 8 Maitenance The instrument s power supply and laser tube will produce high voltage Please maintenance the instrument by professionals in order to avoid an electric shock 8 1 Lens Cleaning After six months for machine output energy will be slightly lower this may be due to Segment focusing lens has been pollution With wet cotton balls graze several lenses be care to avoid lens damage 8 2 Machine chassis cleaning lf there is dust inside the chassis can be used wet cotton cloth dipped into the detergent or toothpaste to clean Fabric should not be too wet to prevent equipment short circuit 8 3 Power calibration
13. ust wear laser goggles to protect eyes from any laser damage threat 3 Please notice that this is a high power laser device and if the patients feel very painful please Stop the laser and check if there is anything happens to the patients skin Adjust it as a proper power that the patients can stand to do the treatment 4 Skin color is very important For white to light color you can adjust the laser power up to 80 100 for a higher performance and the Fuence can be adjusted to 40 90J cm2 For light color to light brown you need a lower laser power 30 60 for example with a longer pulse width to protect any skin burning Also you need to extend the treatment time for the dark skin to inject enough energy to the skin and follicles 5 The skin must be shaved before treatment 6 The handle piece is better to be operated at SCANNING mode It is faster for treatment 7 Skin contact gel is no necessary for treatment It won t make the treatment better or improve the skin feeling 8 You need to wait for several minutes before the cooling tip becomes cold 9 Keep contact between the cooling tip and skin And you can also use the edge of the Aluminum head of the handle piece to cool down the skin during treatment 10 Never shot the laser pulses to eyes or watch the laser directly 11 Please refer to the experience data of Color II Skin hair removal which we provide along with this manual Warranty Notice Please take necessary prote

Download Pdf Manuals

image

Related Search