1. keys to view the options for fluid type Use the appropriate function key to respond Note Depending on the fluid type choice the Transport may ask you for additional information Use the gt keys to view all the options and press the appropriate function key to respond 8 Use the appropriate function key to enable or disable the Reynolds Correction Factor If you enabled the Reynolds Correction Factor use the numeric keys to enter the Kinematic Viscosity and press ENT If not skip to Step 9 December 2003 A Clamp On Transducers cont 9 Use the numeric keys to enter a value for the calibration factor and press ENT Set this factor to 1 0 if the Reynolds Correction is enabled 10 Use the lt gt keys to view the options for the number of traverses Use the appropriate function key to respond 11 The next prompt displays the suggested spacing of the transducers calculated from the entered information Use the Liquid Transducer Installation Guide 916 055 as a guide to installing the transducers on the pipe with the spacing dimension S given here 12 Press ENT to return to the Program Menu You have completed entering data in the Pipe Menu Refer to Saving Site Data on page 12 December 2003 B Wetted Transducers 1 Use the numeric keys to enter the outside diameter or circumference of your pipe Use the appropriate function key to select the desired units and press ENT
2. GE Panametrics Transport Quick Start Measurement Guide December 2003 Process Control Instruments Transport Quick Start Measurement Guide User s Guide 916 022B1 GE Panametrics December 2003 Warranty Each instrument manufactured by GE Panametrics is warranted to be free from defects in material and workmanship Liability under this warranty is limited to restoring the instrument to normal operation or replacing the instrument at the sole discretion of GE Panametrics Fuses and batteries are specifically excluded from any liability This warranty is effective from the date of delivery to the original purchaser If GE Panametrics determines that the equipment was defective the warranty period is one year from delivery for electronic or mechanical failures one year from delivery for sensor shelf life If GE Panametrics determines that the equipment was damaged by misuse improper installation the use of unauthorized replacement parts or operating conditions outside the guidelines specified by GE Panametrics the repairs are not covered under this warranty The warranties set forth herein are exclusive and are in lieu of all other warranties whether statutory express or implied including warranties or merchantability and fitness for a particular purpose and warranties arising from course of dealing or usage or trade lii December 2003 Return Policy If a GE Panametrics instrument malfuncti
3. mail pci panametrics co jp Korea Kwanghee Bldg 201 644 2 Ilwon dong Kangnam Ku Seoul 135 945 Korea Telephone 82 2 445 9512 Fax 82 2 445 9540 E mail jkpark panaeng co kr Spain Diamante 42 28224 Pozuelo de Alarcon Madrid Spain Telephone 34 91 351 82 60 Fax 34 91 351 13 70 E mail info panametrics infonegocio com Sweden Box 160 S147 23 Tumba Sweden Telephone 46 0 8 530 685 00 Fax 46 0 8 530 357 57 E mail pana panametrics se Taiwan 7th FI 52 Sec 3 Nan Kang Road Taipei Taiwan ROC Telephone 02 2788 3656 Fax 02 2782 7369 E mail rogerlin lumax com tw United Kingdom Unit 2 Villiers Court 40 Upper Mulgrave Road Cheam Surrey SM2 7AJ England Telephone 020 8643 5150 Fax 020 8643 4225 E mail uksales panametrics ie USA GE Panametrics 221 Crescent Street Suite 1 Waltham MA 02453 3497 Telephone 781 899 2719 Toll free 800 833 9438 Fax 781 894 8582 E Mail panametrics 9 ps ge com Web www gepower com panametrics Ireland GE Panametrics Shannon Industrial Estate Shannon County Clare Ireland Telephone 353 61 470200 Fax 353 61 471359 E Mail info panametrics ie
4. respond Note Depending on the pipe material choice the Transport may ask you additional questions Use the 5 keys to view all the choices and press the appropriate function key to respond 3 Use the numeric keys to enter the outside diameter or circumference of your pipe Use the appropriate function key to select the units and press ENT If you do not know the outside diameter refer to Sound Speeds and Pipe Size Data 914 004 or use the On Line Help function refer to the User s Manual December 2003 A Clamp On Transducers cont 4 Use the numeric keys to enter the pipe wall thickness If you do not know the wall thickness refer to Sound Speeds and Pipe Size Data or use the On Line Help function refer to the User s Manual 5 Use the appropriate function key to select whether the pipe has a lining If YES proceed to Step a If NO skip to Step 6 a Use the lt keys to view the options for pipe lining material Use the appropriate function key to respond Note f you choose OTHER the Transport then asks you to enter the lining sound speed also refer to Sound Speeds and Pipe Size Data b Use the numeric keys to enter the pipe lining thickness and press ENT 6 Tracking windows are used to detect the receive signal when you are unsure of the fluid soundspeed Press F1 if you do not want a tracking window or F2 if you want to enable the windows 7 Use the
5. 2 Use the numeric keys to enter the pipe wall thickness and press ENT 3 Enter the path length distance between the two transducers described in Appendix B Use the appropriate function key to select the desired units and then use the numeric keys to enter the distance Press ENT 4 Enter the axial dimension refer to Appendix B in the User s Manual Use the appropriate function key to select the desired units and then use the numeric keys to enter a value Press ENT 5 Tracking windows are used to detect the receive signal when you are unsure of the fluid soundspeed Press F1 if you do not want a tracking window or e F2 if you want to enable the windows 6 Use the function keys to choose the fluid type Use the keys to view all the options Note Depending on the fluid type selection the Transport M may ask you for additional information before proceeding to the next prompt 7 Use the appropriate function key to enable or disable the Reynolds Correction Factor 8 If you enabled the Reynolds Correction Factor use the numeric keys to enter the Kinematic Viscosity Press ENT If not skip to Step 9 9 Use the numeric keys to enter the calibration factor Set this factor to 1 0 if the Reynolds Correction is enabled Press ENT Press EXIT to return to the measurement mode You have completed entering data in the Pipe Menu Proceed to Saving Site Data below 10 December 2003 Sav
6. ETRICS INTERNATIONAL OFFICES USA GE Panametrics 221 Crescent St Suite 1 Waltham MA 02453 3497 USA Telephone 781 899 2719 Toll Free 800 833 9438 Fax 781 894 8582 E mail panametrics ps ge com Web www gepower com panametrics ISO 9001 Certified Ireland GE Panametrics Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 61 470200 Fax 353 61 471359 E mail info panametrics ie ISO 9002 Certified July 2003 Australia P O Box 234 Gymea N S W 2227 Australia Telephone 61 02 9525 4055 Fax 61 02 9526 2776 E mail panametrics panametrics com au Austria Waldgasse 39 A 1100 Wien Austria Telephone 43 1 602 25 34 Fax 43 1 602 25 34 11 E mail panametrics netway at Benelux Postbus 111 3870 CC Hoevelaken The Netherlands Telephone 31 0 33 253 64 44 Fax 31 0 33 253 72 69 E mail info panametrics nl 11 Rue du Renard 92253 La Garenne Colombes Cedex France Telephone 33 0 1 47 82 42 81 Fax 33 0 1 47 86 74 90 E mail panametrics panametrics fr Germany Mess und Pruftechnik Robert Bosch StraBe 20a 65719 Hofheim Germany Telephone 49 6122 8090 Fax 49 6122 8147 E mail panametrics Q t online de Italy Via Feltre 19 A 20132 Milano Italy Telephone 02 2642131 Fax 02 26414454 E mail info panametrics it Japan 2F Sumitomo Bldg 5 41 10 Koishikawa Bunkyo Ku Tokyo 112 0002 Japan Telephone 81 03 5802 8701 Fax 81 03 5802 8706 E
7. eters eee eee ee eee 7 Saving Site Data sie ee ee Eee a 11 Displaying Measurements 0 000000 ee eee 12 Transport Quick Start Measurement Guide v December 2003 Introduction This user s guide provides directions for making basic flow measurements It is designed solely to get you up and running as quickly as possible It does not provide a detailed description of the procedures but simply the steps needed to make flow measurements The TransPort December 2003 Keypad Description Since you need to use the keypad in the procedures that follow you should familiarize yourself with the keys and their functions The TransPort keypad has 30 keys each of which has a second function The functions of the keys are as follows see Figure 1 4 feature keys enable you to select the special functions or parameters that appear at the bottom of the screen 12 numeric keys including and enable you to enter numeric data e 4arrow keys enable you to move or scroll the cursor when displaying or entering data 6task keys which perform specific tasks for flowmeter operation Each task key is described in its corresponding section in the User s Manual ENT enters selected values into the TransPort memory EXIT enables you to exit menus or menu options at any time ON turns the power on Shift key the red key enables you to use the second functions of each key which are descr
8. ibed below Each of these keys has a second shift function printed in red above the key For example OFF is the shifted function of the ON key Most of the second functions are letters however there are two keys which have special second functions SHIFT ENT enters the on line help function which is described in the following section SHIFT DISP acts as a space key when you enter descriptions for sites or logs December 2003 Keypad Description cont To execute a shift function press SHIFT followed by the desired key An S appears in the upper right corner of the screen to show that the shift key is activated When you press the shift key twice it locks and an 3L appears The arrow keys also have a third function they enable you to adjust the screen contrast and the beeper volume as described in the User s Manual SITEO VELOCITY Ft s 12 43 E0 NO ERRORS VEL VOLUM TO DI En 4 O O rr 7 x O o s a Dla r gt 9 y E m 2 lt FLOWMETER Figure 1 Transport Keypad December 2003 Powering On and Off To operate the TransPort the power cord must be plugged in to line voltage or the battery must be fully charged as described in Chapter 2 of the User s Manual Initial Setup Use the ON key in the upper right hand corne
9. ing Site Data Now that you have entered all the necessary data the Transport will give you the opportunity to save it using the following steps 1 To enter the Save menu use the lt gt keys to scroll until SAVE appears on the screen and press F1 2 Use the alphanumeric keys to enter a name 5 character max for the site 3 Press ENT You have completed programming the Transport for quick flow measurement Press EXIT and the Transport begins displaying measurements You may program as many sites as you wish using the same steps however it is a good idea to read Chapter 3 Programming Site Data in the User s Manual for more details December 2003 Displaying Measurements Once the Transport is programmed you can display the following measurements on the screen Velocity e Volumetric Forward Totals Reverse Totals If you are measuring energy you may also display Power Forward Energy Reverse Energy Each of the above measurements is assigned a function key Use the gt keys to view all the options To display the desired measurement simply press the corresponding function key The measurement automatically appears on the screen in the units selected previously while in PROGram Refer to Chapter 4 Displaying Data in the User s Manual for more information on displaying measurements MAIN OFFICES GE Panametrics WORLDWIDE OFFICES GE PANAM
10. of supply where the liquid enters 11 Press the F1 function key to accept the current date or F2 to edit the date If you choose to edit the date the Transport requests the year the month and then the day 12 Use the same procedure as described in step 11 to enter the time You have completed programming the system parameters Press EXIT to return to measurement mode Then proceed to the following section December 2003 Pipe Parameters This section describes how to enter pipe parameters for all standard transducer types If you are using a special transducer refer to Appendix A in your User s Manual Use the following steps to enter the pipe parameters 1 Press F3 to enter the Pipe Program menu 2 Enter the transducer number that is engraved on the transducer 3 Press ENT The following series of prompts depends on the type of transducer you are using clamp on see below or wetted see page 10 Refer to the appropriate section that follows to enter the pipe parameters Clamp On Transducers 1 If you are using medium to high temperature clamp ons the Transport asks you to select whether the input is active or fixed Press F1 for an active input or F2 for a fixed input If you have a fixed input enter the approximate wedge temperature using the numeric keys and press ENT 2 Enter the pipe material by using the keys to view all the options Use the appropriate function key to
11. ons within the warranty period the following procedure must be completed 1 Notify GE Panametrics giving full details of the problem and provide the model number and serial number of the instrument If the nature of the problem indicates the need for factory service GE Panametrics will issue a RETURN AUTHORIZATION NUMBER RAN and shipping instructions for the return of the instrument to a service center will be provided 2 If GE Panametrics instructs you to send your instrument to a service center it must be shipped prepaid to the authorized repair station indicated in the shipping instructions 3 Upon receipt GE Panametrics will evaluate the instrument to determine the cause of the malfunction Then one of the following courses of action will then be taken Ifthe damage is covered under the terms of the warranty the instrument will be repaired at no cost to the owner and returned f GE Panametrics determines that the damage is not covered under the terms of the warranty or if the warranty has expired an estimate for the cost of the repairs at standard rates will be provided Upon receipt of the owner s approval to proceed the instrument will be repaired and returned iv December 2003 Table of Contents Introduct Ons s odas ate NO NE e Ned ae 1 Keypad Description 2 Powering On and Off 4 Programming System and Pipe Parameters 5 System Parameters eee eee eee eee 5 Pipe Param
12. r to turn the unit on Immediately upon power up the TransPort M displays the GE Panametrics logo and the software version The meter will then perform the following self checks and display their conditions EPROM checksum RAM test NOVRAM test Backup battery test Time and date test If the meter fails any of these tests contact GE Panametrics IMPORTANT 7f the meter fails the backup battery test send the unit to the factory for a battery replacement Keep the NiCad batteries charged until you are ready to ship the unit back to the factory Before shipping print out all the log and site data After the meter conducts all the self checks the screen then appears similar to the one shown in Figure 2 below To turn the Transport off press SHIFT the red key and ON PROGRAM VELOCITY 12 50 E1 Low Signal Figure 2 Screen After Pressing ON December 2003 Programming System and Pipe Parameters For the TransPort to begin taking measurements you must enter the system and pipe parameters Once these parameters are entered you may save them and edit them at a later time PROGRAM PROGRAM Pipe parameters Raia KAWI BA NE Figure 3 Screen After Pressing the PROG Key System Parameters Use the following steps to enter the system parameters 1 Enter site data by pressing the PROG key on the keypad The screen should appear similar to that in Figure 3 above 2 Press the F2 ke
13. y to enter the System Program menu 3 Use the appropriate function key to select the energy option Note f you respond yes the Transport requires that you either have two temperature transducers connected to the analog input or that you enter two fixed temperatures see page 3 28 in your user s manual 4 Use the keypad and the shift function to enter an alphanumeric message then press ENT for the site description 5 Choose the system unit Use the proper function key December 2003 Programming System and Pipe Parameters cont 6 The next prompt Stopwatch Totalizer enables you to either totalize all liquid flow continuously or to manually start and stop totalizing liquid flow Press F1 to select automatic totalizing or F2 to select manual control 7 Use the proper function key to choose the volumetric units Use the keys to view all the available options 8 Use the proper function key to choose the totalizer units Use the gt keys to view all the available options 9 If you are measuring energy the Transport prompts you to select the following a Use the proper function key to choose the units for power b Use the proper function key to choose the units for total energy c Use the proper function key to select whether your system is for heating or cooling 10 Press F1 to measure flow at the point of return where the liquid exits or F2 to measure flow at the point

Download Pdf Manuals

image

Related Search

Related Contents

  9.2 WEB-BASED INQUIRY - PPS - University of California, Santa Cruz  GE GSD6900 User's Manual  Bedienungsanleitung Mode d'emploi Istruzioni per l'uso Instruction  60cm Geschirrspüler GSP 14056 V 60cm Geschirrspüler GSP 14056 V  64 I/P and Encoders (Config Manual - Ver 4.0.0)  411572 Storage Cabinet  SDI6350P15 - Oil India Limited  Manual  Cliccate qui per un nuovo  