Home
Page 1 of 20 USER MANUAL OF ANTI
Contents
1. Super Safe in water solution Page 8 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 3 APPLICATION 3 1 Preparation for AIT 3 1 1 Control of the surface condition of aircraft for presence of SIS Every AIT starts with control of the surface condition of the aircraft All SIS found have to be removed from the surface of the aircraft Depending on the weather conditions on the surface of aircraft different kinds of SIS form on the surface of aircrafts high humidity leads to formation of SIS on the surface of aircrafts directly from air by means of sublimation like frost or ice cap freezing fog drop crystal or of mixed type leads to formation of hoar frost granular or crystal downfall types like snow freezing spit freezing rain form snow or ice scurf and also mix of snow and water mire and snow and ice snow ice gruel Presence of fuel in the wing tanks of the aircraft whose temperature is much less than T aa might lead to formation of local SIS on the surface of the wing in critical zones in form of smooth transparent granular snow cap This type of SIS might appear at T aa up to 15 C and high humidity or rain of spit 3 1 2 Selection of AIF Nizh Yug Air Super Safe concentration and time of protective activity If the planned flight is performed without on ground icing conditions then SIS is removed by
2. Fluids anti icing type I SAE ARP 4737 Aerospace Recommended Practice Practical Recommendations Page 20 of 20
3. USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 8 AIF Nizh Yug Air Super Safe WORKING SAFETY REQUIREMENTS While working with AIF Nizh Yug Air Super Safe and its solutions means and methods of providing working safety must meet the requirements of the System of standardization of worker safety Anti icing fluid belongs to the 4 class of danger in terms of the degree of effect on the human organism according to GOST12 01 007 Hazardous substances Classification and General safety requirements People who involve in treatment of aircrafts with AIF must pass a previous training before they are accepted for the job and periodical medical tests trainings according to TH 2 1 6 1338 03 Maximum Permissible Concentrations MPC of the hazardous substances in atmospheric air While working with AIF one should use individual means of protection from getting AIF on skin eyes breath organs and digestive system in accordance to requirements TOCT 12 4 004 Means of safety of workers general requirements and classifications TOCT 12 4 034 Means of individual safety of breathing organs Classification and Marking TOCT 12 4 103 Special protective clothes Means of individual protection of feet and hands Classification WARNING 1 While working with AIF one should avoid it getting on skin and eyes In such a case
4. 003 26759308 2005 MANUFACTURED BY ARCTON LTD 2 2 APPLICATION FACTORS MAIN OUALITY SPECIFICATIONS Solution Freezing Temperature limit of Water vs AIF temperature T f applicability T at C Deflection factor Ratio C min min KEK 100 00 55 35 1 4125 95 05 48 33 1 4084 90 10 42 31 1 4042 85 15 37 27 1 4001 80 20 32 22 1 3960 75 25 28 18 1 3918 70 30 24 Eb 1 3877 65 35 21 es 1 3836 60 40 18 xk 1 3794 55 45 15 Eg 1 3753 50 50 13 Es 1 3712 45 55 ill Ex 1 3670 40 60 9 a 1 3629 35 3 OS 8 ER 1 3588 30 70 6 an 1 3546 NOTE temperature limit of application T a is stated with consideration of temperature supply and temperature limit At of aerodynamic applicability T aa which is defined in accordance to the tests see table 2 1 i 8 T values of are not shown for solutions with concentration of AIF Nizh Yug Air Super Safe less than 75 by volume since for these kinds of solutions the compliance of its characteristics to the reguirements applied to fluid type I maximum permissible deviation from given values of deflection factor are 0 0020 For practical use of water solutions of AIF in case of deviation of the indicators from the values shown in the table 2 2 use of graphs of dependence of deflection factor is recommended fig 2 1 and graph of freezing temperature fig 2 2 on concentration ratio of AIF in water solution Page 6 of 20 USER MAN
5. basis for use of this AIF solution is documenting of its factors shown in table 2 2 AIF concentration in solution T a Ts In case of non conformity of water quality with requirements of the table 4 1 its use must be approved by the manufacturer of AIF Nizh Yug Air Super Safe WARNING The values of the factor of deflection of the final solution may be different from the values shown in the table In this case concentration of solution and T are defined by graphs fig 2 1 and 2 2 respectively Page 16 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 5 AIF NIZH YUG AIR SUPER SAFE WORKING EQUIPMENT QUALITY CONTROL For supplying reliable anti icing protection on aircrafts an important feature is the quality of work of the fluid system of the used equipment One should rightly select the needed equipment and different components of the fluid system pumps heating systems pipes etc and regularly check the quality of their work In order to avoid changes in physicochemical characteristics of AIF Nizh Yug Air Super Safe and its water solutions heat transformers and heating elements in the heating systems must be used which provide the temperature where needed on the aircraft surface of not more than 90 C It is essential to provide a constant unbreakable circulation of fluid in the system In case if the temperature of the heating
6. corrosive barrels according to GOST 26155 in glass bottles according to TY 6 09 5472 with volume of 20 dm in automobile or railroad steel containers according to GOST 10674 Also shipment of AIF in user s containers is possible if there is an act of cleaning for the container designed in the reguired manner AIF Nizh Yug Air Super Safe is kept in a 100 sealed container with temperature not less than minus 50 C and not more than plus 50 C Access of downfall or of ultraviolet light is not acceptable under any conditions Heated up to 80 C AIF Nizh Yug Air Super Safe and its solutions with water can be kept up to 2 weeks in tightly sealed containers WARNING Overheating of AIF may lead to thermal destruction and worsening of functional gualities of AIF Entering registering and storing guality control during receiving and storing AIF Nizh Yug Air Super Safe in companies is realized in a certified laboratory Certification Centers or in Scientific Centers During the receiving guality control in Civil Aviation companies the products are controlled in following certain areas Deflection factor General appearance Kinematics viscosity Under bad results of guality control and also in case expiry date passes samples of AIF are selected and sent to Scientific Centers on NSRI or to the manufacturer of the fluid for making the expertise research and making decision about future use of AIF Page 18 of 20
7. surface is higher than 90 C a continuous heating circulation of the fluid has to be provided inside the heating system The equipment for AIT must confirm with the requirements of international standard ISO 11077 5 1 Control of accurateness of work of the mixing system If the equipment used for AIT has a system of mixing of AIF with water that in the management of the operator the degree of accurateness of its work should be shown This information is needed for achieving reliable anti icing protection and for checking the quality of work of mixing system The control of work of the mixing system is done in the following manner tanks are filled with sufficient amount of fluid water and AIF Nizh Yug Air Super Safe the mixing system is run and the wanted ratio AIF water is selected remove air locks from the system until AIF solution without air locks appears on the exit of the injector point the flow from injector into container connected with plastic bag of corresponding sizes and quality and fill it with abundant amount of fuel compare the deflection factors of the selected sample and reference sample mixed by hand One should control the accuracy of AIF water ratio in the solution 6 AIRPORT EQUIPMENT REQUIREMENTS FOR AIT Aircraft AIT is done on a specially equipped parking place in accordance with recommendations of the Management of anti icing protection on aircrafts Doc 9640 AN 940 UCAO 2000
8. surface of aircrafts on the first stage of the two stage treatment without account of At These fluids i e concentrated AIF and its water solutions can be both not heated and heated until the temperature of not more than 80 C on the exit of the sprinkler Supply of AIF by the producer is performed in concentrated form AIF solutions are realized differently 1 2 2 Temperature limits of application T a AIF Nizh Yug Air Super Safe and its water solutions with AIF concentration of not less than 75 by volume confirm with the requirements applied for the fluids of type I T a confirms the lowest T a for more than which use of this AIF solution is accepted with consideration of temperature supply of At in accordance to T of AIF or solution and with consideration of temperature limit of aerodynamic applicability T a see table 2 1 Temperature supply At normative difference between the freezing temperature of AIF or its solution and temperature of the atmospheric air for AIF type I At 10 C for type II and IV At 79C therefore T Trt At Taal For concentrated AIF Nizh Yug Air Super Safe T a gt 35 C see table 2 2 For water solution 75 25 by volume T aa 18 C see table 2 2 1 2 3 Temperature limits for using AIF water solutions only for removing SIS without supplying the proposed time of use Tr of the solutions used in heated form for SIS removal on the first stage treatment of aircr
9. the fluid has to be removed using a big amount of water 2 While performing AIT the operator should use respirator and stay on the windy side of the sprinkled AIF 3 While performing AIF on wing of an aircraft the operator should be especially careful in terms of slippery surfaces from AIF Page 19 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I BOM Ee 10 11 12 13 14 15 16 TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD BIBLIOGRAPHY Technical reguirements appointed to AIF approved by MCA 1992 HAN TA 85 Recommendations on Civil Aircraft Building HT PAT 93 Recommendations on use and repair of aviation technology Methodical recommendations for anti icing protection of CA approved by Ministry of Transportation of Russian Federation 23 01 2003 Testing methods for anti icing fluids for effectiveness approved by Russian Ministry of Transportation 14 03 2003 Testing manual for AIF in terms of their evaluation on elements of design of the aircraft approved by Ministry of Transportation of Russian Federation 7 11 2002 Anti icing fluid Nizh Yug Air Super Safe Type I TECHNICAL CONDITIONS Ty 2422 003 26759308 2005 Tests of anti icing fluid AIF Nizh Yug Air Super Safe Type I on evaluation of protection time in climatic room of Certification Center of NSRI Conclusion approved by deputy general director of and director of National Scientific Rese
10. D NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD ABSTRACT Efficient use of AIF is the most important factor of assuring the safety aircraft take off and the regularity of flights in the on ground icing conditions The use of anti icing fluid is aimed at reaching this result for the aircraft surfaces which also complies with the HNN TA 85 and the clean aircraft concept The use of anti icing fluid for anti icing treatment of aircrafts is subject to e Instruction Manual in accordance to HT3PAT 93 e AIF instruction manual e AIT instruction of the company which does the on ground service of the aircraft Efficient use of AIF depends on the human factor Selection of appropriate AIF type and concentration for the needs of each anti icing treatment weather conditions and state of the aircraft surface and quality control of shape of the treated surface depend only on the working staff In accordance to the NSRI and current requirements for Civil Aviation in Russian Federation all the flying and ground staff has to pass the training program Protection of aircraft from on ground icing The personnel that have access to the immediate AIT of the aircraft have to thoroughly know the User manual of this AIF The flying staff also has to have exact knowledge about anti icing procedures performed on aircrafts while they are on the ground as well as the protecting characteristics of AIF which
11. For providing of quality of treatment and possibility of control of the state of the surface of aircraft in dark time of the day the parking places must have good lighting equipment During AIT of aircrafts the safety measures foreseen during the use of hazardous materials of 4 class collection and utilization of used AIF Nizh Yug Air Super Safe based on diethylene glycol no leaks etc have to be guaranteed Page 17 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 7 SUPPLY AND STORAGE AIF Nizh Yug Air Super Safe is supplied by the manufacturing factory with accompanying documents that include document of guality for AIF party from which the shipment is made copy of Sanitary epidemiologic conclusion hygienic certificate copy of Certificate of compliance User s Manual approved by NSRI and AIF manufacturer NOTE 1 In document of guality the physicochemical factors of AIF are shown 2 Information about Certificate of compliance and Sanitary epidemiologic conclusion can be shown in the Document of guality AIF Nizh Yug Air Super Safe is shipped in containers in compliance with requirements TY 2422 003 26759308 2005 in dry steel barrels according to GOST 6247 type I or 2 with volume of 200 or 275 dm according to GOST 13950 type I with volume of 100 or 200 dm according to GOST 17366 with volume of 275 dm in anti
12. OUALITY SPECIFICATIONS AND APPLICATIONS MAIN OUALITY SPECIFICATIONS Appearance Density at 20 C g cm Deflection Factor at 20 C Surface Tension mH m max Flash Point in Open Cup C min PH Factor at 20 C Kinematics Viscosity at 20 C mm sec min Temperature Limits of Aerodynamic Applicability of AIF solution C at AIF concentration 100 0 79 25 NOTE Standard SAE AMS 1424E Homogenous transparent or semi transparent colorless or colored fluid 0 015 from manufacturer 0 015 from manufacturer 5 from manufacturer 100 0 5 from manufacturer 5 from manufacturer Is defined based on the results of the research in acc to SAE AMS 1424E Standard TY 2422 003 26759 308 2005 Homogenous from transparent to yellowish color fluid 1 094 1 102 1 4090 1 4160 40 9 50 5 9 0 35 C 24 C Testing Method Visually GOST 18995 1 ASTM D 891 GOST 18955 2 ASTM D 1747 5 4 of TU 2422 003 26759308 2005 ASTM D 1331 GOST 4333 ASTM D 93 GOST 22567 5 ASTM E 70 GOST 33 ASTM D 445 SAE AMS 1424 amp as 5900 1 Values are complying with the Certificate of Analysis for particular Lot Party 2 Each two years the controlling tests are carried out within the specially certified laboratory of Scientific Center of NSRI Page 5 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422
13. UAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD Deflection Factor 141 138 137 136 1 35 15 20 26 30 36 40 45 50 55 60 65 70 75 80 85 90 95 100 Concentration Ratio of AIF NIZH YUG AIR SUPER SAFE in Water Solution Fig 2 1 Dependence of deflection factor on concentration ratio of AIF Nizh Yug Air Super Safe in water solution Page 7 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 4 cp we eee ge ee pee Jn n en o oj S 6o 0 180 B 70 SA ee r7 n i i w 2 30 40 7 4 7 4 FU r s e Concentration Ratio of AI i i i i EU N F A A bela C HS a HE o Has i i i r a i i i i i Lc Mrs aal ie NN MW Sn nin rn i i i i i i i i i i j BR er ee ee ee ene i i i i i i Fa HF HE RH HY DH EP i i i i i 3 4 roa e MM dU Semin besdeccdes Th i i Er ae ee ee ae aes See See wee Fig 2 2 Dependence of freezing temperature on concentration ratio ee eee eee eee ee eee ee ee a Wenn new Yr UU en NIZH YUG AIR SUPER SAFE in Water Solution bo 2 m nd n fn mm shade deheu hb ee en re gn a ly gyn ges Fm y a Se See eee en ym yu eu yd of AIF Nizh Yug Air
14. USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD VALID UNTIL 01 AUGUST 2008 Page 1 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD Accepted abbreviations ACC Aviation Certification Center AC Aircraft CA Civil Aviation NSRI National Science Research Institute AIF Anti icing fluid AIT Anti icing treatment SIS Snow ice scurf Tr Freezing temperature of AIF and its water solutions Tsa Temperature of atmospheric air Ta Temperature limit of using AIF and its water solutions the lowest T at which this fluid can be used for protection of aircraft from on ground freezing T aal Temperature limit of aerodynamic applicability the lowest T at which this AIF or its water solution will be removed from surface of the aircraft by the coming air before the take off point during the run out CC AviaMF Certification Center of Aviation Motor Fuels IM Information Manual AEA Association of European Airlines AMS Aerospace Material Specification ASTM American Society for Testing and Materials ISO International Standards Organization SAE Society of Automotive Engineers At Temperature supply normative difference between freezing temperature of AIF or its water solution and temperature of air in the environment Page 2 of 20 USER MANUAL OF ANTI ICING FLUI
15. accordance to weather conditions the following methods of anti icing treatment using AIF Nizh Yug Air Super Safe can be recommended 3 2 1 Making the AIT in single stage A The on ground icing conditions have stopped and are not predicted Removing of SIS from surface of the aircraft is done be AIF or its water solution heated to a temperature no more than 809C Concentration of AIF in the solution is defined based on the values of T aa T s and temperature supply At or at T aa lt 18 C by the condition T aa T a table 2 2 B On ground icing conditions exist or are predicted AIF concentration in solution not less than 75 or concentrated AIF are selected in accordance to concrete conditions so that T a T a table 2 2 and that after removal of SIS the remaining fluid on the aircraft surface does not allow formation of new SIS for the time needed table 3 1 WARNING 1 Amount of fluid must be enough for full removal of SIS 2 While removing of SIS the concentration and protective time of AIF reduces 3 AIF concentration in solution is selected higher with cold fuel in the wing fuel tanks and temperature of the wing coating lower than T 4 If the protection time of the available AIF is critical AIT is always done in two stages On the second stage AIF which provides the needed protection time is used 3 2 2 Making AIT in two stages The most trusted method of protection from formation of SIS is AIT in two stages
16. aft can be higher than T aa but not by more than three degrees Celsius T rof the solutions used in heated form for SIS removal on the single stage treatment of aircraft must lower than T aa by 10 degrees by the amount of temperature supply of At Thus AIF solution with volume concentration AIF water 50 50 in heated form can be used at T ss at not lower than 16 C on the first stage of the two stage treatment and not lower than 39C for SIS removal in one stage treatment of aircraft in the absence of on ground icing conditions 1 2 4 Compatibility with other AIF AIF Nizh Yug Air Super Safe and its water solutions for two stage AIT of aircrafts confirm with other AIF types II and IV on the basis of ethylene glycol and propylene glycols Mixing of AIF Nizh Yug Air Super Safe and its water solutions with other AIF is not allowed All the equipment and the fluid system in which the AIF of other made was contained have to be washed 1 2 5 In windy weather applying and spraying of AIF on the surface on aircraft gets harder In case of impossibility of quality application of AIF the treatment is not made 1 2 6 AIF Nizh Yug Air Super Safe keeps its factors and characteristics as long as the requirements rules and regulations stated in the Manual are followed Page 4 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 2 MAIN
17. arch Institute on 10 02 2006 Conclusion on the results of the tests of sample of anti icing fluid Nizh Yug Air Super Safe Type I produced by Arcton Ltd Nijnekamsk for effectiveness and aerodynamic applicability Approved by deputy general director of Scientific Center NSRI of CA on 14 11 2005 Manual for anti icing protection of aircrafts on earth Doc 9640 AN 940 2nd edition 2000 Federal aviation rules Certification reguirements to the organizations of aviation service for air transportation approved by decision No 89 on 18 04 2000 Russian Ministry of Transportation registration of Ministry of Justice of Russia No 2411 5 10 2000 Federal aviation rules Certification reguirements to the organizations of guality control service of aviation fuels oil and special fluids for aircrafts approved by Regulation No 126 of 17 10 2002 Ministry of Transportation of Russian Federation Registration of Ministry of Justice of Russian Federation No 3867 18 10 2002 Conclusion No 133 5 05 on Testing the anti icing fluid Nizh Yug Air Supersafe type I produced by Arcton Ltd Approved by director Certification Center of NSRI Moscow 2005 Decision No 183H 05 from 16 12 2005 of awarding the Certificate of Conformity to the GOSTP to Arcton Ltd for anti icing fluid Nizh Yug Air Super Safe International standards SAE AMS 1424D De icing anti icing Fluid Aircraft SAE type I Society of Automotive Engineers
18. be used hand sprinkler and a container Control of the condition of treated and untreated surfaces of the wing must be done before taking away the aircraft from the park One needs to be sure that there is no ice on both halves of the wing both visually and by feel The fluid layer on the surface of the aircraft must be viscous smooth without blur clots and crystals Page 15 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 4 AIF NIZH YUG AIR SUPER SAFE SOLUTIONS PREPARATION AND QUALITY CONTROL Preparation of AIF Nizh Yug Air Super Safe solutions by the user shall be as follows Used equipment must be washed for avoidance of other additions from getting mixed into AIF Quality of water requirements for mixing with AIF are given in table 4 1 Concentrated fluid is added into water cold or hot or the water cold or hot is added into concentrated fluid Preparation of water solutions is done on standard equipment WATER QUALITY REQUIREMENT FOR AIF NIZH YUG AIR SUPER SAFE SOLUTION MAIN QUALITY SPECIFICATIONS Normative Values Testing Method Appearance Homogenous transparent Visually by looking at sample of colorless fluid without water in cylinder from colorless mechanical additives glass with diameter 20mm in passing light Total hardness mg ekv It max Not more than 7 GOST 4151 pH factor 6 0 9 0 GOST 22567 5 The
19. do it in up and down direction of the surface of aircraft One should avoid the fluid from getting on the transducers of full and static pressure indicators of direction and speed and the corner of attack NOTE At the end of AIT the pilot team is given a special encoded data type of the AIF and concentration time of the beginning of protection process date for example Typel 75 1200 13November2006 Fact of transfer of this data proves that AIT is finished and aircraft is clean Discharge rate of AIF Nizh Yug Air Super Safe and its water solutions for AIT Amount of fluid AIF or its water solutions used during the SIS removing procedure should be enough for total cleaning of the aircraft surface affected by SIS The discharge rate depends on total mass of the SIS on the surface which is frozen to the aircraft on the means used for applying the fluid on the surface on the qualification of the staff performing the AIT WARNING Aircraft surface after AIT must be humid smooth and bright without blur crystals or clots Not abundant amount of fluid leads to decrease in quality of treatment cleaning of surface of aircraft from AIT decrease in time of protective activity Page 11 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 3 2 METHODS OF AIT OF AIRCRAFTS USING AIF Nizh Yug Air Super Safe In
20. ethods and the methods of applying AIF used Page 10 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I 3 1 4 1 3 1 4 2 3 1 4 3 TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD Preparation of aircraft and for AIT has to meet all the reguirements of standard technical documentation PO P3 PJI2 etc for each type of the aircrafts Before the AIT fix the moving surfaces of the aircraft into a position explained by the aircraft designers for this certain type of aircraft Methods and means for AIT must be approved by the pilot team of the aircraft During the preparation for AIT all the doors windows and hatches have to be closed and sealed motor has to be guieted down from motor Manual and the indicators and eguipment covered WARNING During AIT recommendations that are stated in Manual should be followed based on type of the aircraft these are maximum possible temperature and pressure AIF solution on the exit of the sprinkler aircraft configuration direction of the flow of the fluid and other points and restrictions on the design elements of the aircraft One should not point the flow of AIF water or solution on the working mechanisms in order to avoid danger on the paint from fluid If the fluid AIF or solution gets on the electro heating glasses of the pilot cabin it should be carefully removed One should apply the fluid symmetrically on both wings and stabilizers and
21. f downfall include hard snow blizzard snow rain mild freezing rain and hard freezing rain the given values for the protective effect time are recommended at T aa gt 09C EXPLANATIONS In case of hardship in defining the type of the icing conditions and or their intensiveness one should apply the harsher conditions and use concentrated AIF Factors leading to lessening of the protective effect time _ high intensity of the downfall intensive wind airflow from a near passing aircraft presence of fuel in the fuel with temperature lower that atmospheric air WARNING During performing AIT with consideration of the protective effect of the fluid concentrated AIF Nizh Yug Air Super Safe or its water solution with concentration of AIF not less than 75 by volume one should pay attention to that after the AIT of the aircraft surface be covered with a compact film of fluid Possibility of breaks in this film shows that the fluid in these conditions of AIT wind mix of other internal factors does not have protective effect The company and the staff who performs AIT in process of using AIF Nizh Yug Air Super Safe and its water solutions has to gain and publish the experience look 10 part 5 both on finding and estimating the recommended protective effect time and in application to the local airport local weather conditions which actually show the most popular reasons for on ground icing AIT m
22. icing conditions on the top of aircraft a big mass of SIS is collected For removal of SIS frozen to the coating of the aircraft heated fluid AIF of its water solution is recommended for use in the following matter Fluid flow must be directed to one point for thawing out of SIS all the way to the coating The heat on the coating which has very high thermal conduction with transfer to the close areas and connection of SIS with coating will be broken The same procedure should be repeated in various points on the treated surface with removal of the layered SIS by means of flow of the fluid at needed force Removal of local SIS In order to remove ice formed as a result of overcooling of the wing in places where fuel tanks are placed with temperature much lower than T aa critical zones heated AIF is used water solution For application of the fluid portable equipment can be used hand sprinkler and container which confirm with requirements applied to the AIT equipment The equipment used for standard AIT may be used on minimal mode of serving by thin flow Page 14 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 3 3 2 Anti icing protection Protective AIT is done in on ground icing conditions or in case of prediction of those For maximum effect on the protection of aircraft from SIS formation before the protective procedure the surface of the ai
23. ion of solution is temperature supply of 10 C not used selected based on T aand T a Lower considering T a lt 189C Trof AIF water solution can be and in accordance with required than 3 conditioned by Ta gt T a by 3 C higher than T aa protection time WARNING 1 AIT of the first stage is done not later than 3 minutes after ist stage for avoiding the possibility of freezing of the fluid used in the first stage 2 Amount of fluid must be abundant for creation on a homogenous protective layer of AIF on the surface of the aircraft 3 AIF concentration in solution is selected higher while cold fuel is there n the wing fuel tanks and the temperature of the coating is less than T aa Page 13 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 3 3 PROCEDURE OF AIT OF THE AIRCRAFT WITH USE OF AIF Nizh Yug Air Super Safe 3 3 1 Removal of SIS General facts For reaching the maximum effect while removing the SIS from the surface of the aircraft AIF water solution should be used with temperature on the exit of the sprinkler not less than 60 C and not more than 80 C For each type of aircraft temperature and pressure of the fluid on the exit of the sprinkler might be bounded by the aircraft designer look the Manual For minimal loss of heat AIF has to be applied on the aircraft surface from a minimal distance Concentration of the so
24. is used on the aircraft before the take off Use of hazardous and specific substances in the make up of AIF has to be accounted by the user of AIF while providing a work safety of the AIT personnel b ecological safety c technological processes of AIT particularly AIF creates slippery conditions on the surface of aircrafts and airports User manual of anti icing fluid Nizh Yug Air Super Safe Type I TY 2422 003 26759308 2005 manufactured by Arcton Ltd was developed based on typical manual of NSRI User manual of anti icing fluid Page 3 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 1 GENERAL 1 1 AIM 1 1 1 AIF Nizh Yug Air Super Safe Type I is intended for removal of SIS from the surface of the aircrafts and as a short time protection from SIS formation in conditions of on ground icing see table 3 1 It is manufactured in concentrated form with minimum 65 of diethylene glycol and addition of surface active and anti corrosive substances 1 2 Usage conditions 1 2 1 AIF Nizh Yug Air Super Safe can be used in concentrated form in form of water solutions with concentration not less than 75 by volume AIF solutions with concentration of less than 75 by volume by protection time do not fully comply with to the requirements to type 1 fluids however they can be used in order to remove SIS from the
25. lution is selected T a with consideration of At based on the values T a and T for the corresponding solutions see table 2 2 and with consideration of availability of cold fuel in wing fuel tanks T of the solution used in heated form for SIS removal on the 1 stage of double stage AIT might be higher than T aa by no more than 39C value of At is not considered here Removal of frost ice caps hoar frost Little amount of SIS in frost form ice caps and hoar frost not connected to the coating very strongly is removed from the aircraft surface by means of a mouthpiece which allows to get the needed flow of AIF SIS in form of granule frost may reach high masses for their removal recommendations in the Frozen SIS removal part should be used Snow removal Temperature and pressure of the AIF solution is recommended to regulate depending on the amount of structural SIS SIS may be in snow wet snow or snow with water mire form NOTES Before the AIT using AIF Nizh Yug Air Super Safe using of other means of heavy SIS removal look logical mechanical means hot water warm air However in this case all the requirements and restrictions connected to the use should be met WARNING Underneath snow layer there may be a thin layer of ice which must be controlled both before and after the AIT Removal of frozen SIS During a long stay on the ground of the aircraft which is accompanied by positive or negative effect on the on ground
26. rcraft must be fully cleaned from SIS that collected on it before The most effective application of AIF first on the up most areas of the aircraft surface so that when it flows down it will affect the surfaces lying down and AIF continues to work AIT protection is done directly before the start and in maximum short time without loss of the quality of treatment So the surface of aircraft must be covered by a solid homogenous layer of liguid which is needed to be visually controlled in the process of AIT Before the take off the aircraft surface with applied fluid has to stay smooth bright without clots crystals or blurriness AIF or its water solutions have to keep viscosity and drop off the wing of stabilization The shape of the surface of aircraft after AIT must be controlled up until right the take off WARNING Aircraft must be returned back for repeated treatment if on the surface of the aircraft SIS has formed the protective time has run out The repeated AIT in the on ground icing is always double stage Local protection AIT of the critical parts of the wing protection of the wing surface from formation of ice in the fuel tank region In working practice of each company usually the critical zones of the wings of the treated aircrafts are found The fluid is applied on the critical zones of the wing console symmetrically right after the landing of aircraft To apply the protective layer of AIF portable equipment needs to
27. see table 3 2 First stage of AIT removal of SIS may be performed by heated to 80 C AIF Nizh Yug Air Super Safe or its water solutions while their T can be by 39C higher than T aa for SIS removal on the first stage hot air and hot water and might be used as well as mechanical means of cleaning the surface of aircrafts following all the restrictions on their use according to the Manual Second stage of AIT applying protective layer of AIF or its water solution On the second stage pure AIF Nizh Yug Air Super Safe or its water solution with concentration of AIF of not less than 75 by volume selected by the condition T a gt T a from table 2 2 is being applied in such a way that it can totally remove from the aircraft surface the leftovers of the fluid after the 1 stage and create a protective layer of AIF Page 12 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD APPLICATIONS PROPOSALS FOR AIF NIZH YUG AIR SUPER SAFE AND ITS WATER SOLUTIONS ON T ag MAIN OUALITY SPECIFICATIONS Double Stage T aar C Single Stage ATT A SIS Removal B SIS Protection 3 and AIF Nizh Yug Air Super Water of AIF water solution Is done not later than 3 higher Safe or its water solution heated to 80 C If temperature minutes the first stage of AIT heated to 80 C with of wing is less than 3 C water is Concentrat
28. the most optimal method without control of the protection activity time of AIF At temperature values of the surrounding air minus T aa 18 C and less then by condition T a Ta and at T aa 2 18 C then by condition T aa gt T At T 10 C If the planned flight of aircraft is performed in the condition of on ground icing airport service has to approve with the pilot team selection of the AIF concentration concentrated AIF water solution with AIF not less than 75 by volume defined by the weather conditions at each concrete AIT and also by the staff work experience Selection of the AIF Nizh Yug Air Super Safe concentration depends on the following factors weather conditions T aa type of downfall wing speed temperature of the wing surface AIF protection activity time period of time during which the AIF layer applied on the aircraft surface prevents formation of SIS under these weather conditions The time count for protection activity time starts at the moment of contract of AIF with the surface of aircraft during the one stage AIT or from the beginning of AIF contact with surface during two stage AIT The corresponding coded information must be given by the on ground service to the pilot team after the end of AIT Recommendations for the average protective effect time Holdover time AIF Nizh Yug Air Super Safe and its water solutions with AIF ratio not less than 75 by volume depending on the
29. type of downfall and T aa are given in table 3 1 Page 9 of 20 USER MANUAL OF ANTI ICING FLUID NIZH YUG AIR SUPER SAFE TYPE I TY 2422 003 26759308 2005 MANUFACTURED BY ARCTON LTD 3 1 3 AVERAGE PROTECTIVE EFFECT TIME IN MINUTES FOR DIFFERENT WEATHER CONDITIONS MAIN OUALITY SPECIFICATIONS T 9C Higher than 3 from 3 to 6 from 6 to 10 10 and lower NOTE Frost Freezing Snow Freezing small Rain of Other Snow Fog Very Weak Mild Spit freezing cold types of cap weak rain Mg downfall lt fuel freze gt 45 11 17 18 22 11 18 6 11 9 13 2 5 2 5 Le 45 8 13 14 17 8 14 5 8 5 9 2 5 45 6 10 11 13 6 11 4 6 4 7 2 5 No recommendations on holdover time 45 5 9 7 8 4 7 2 4 No data for the intensive frost formation conditions very weak snow visibility not less than 3200 m weak snow visibility not less than 2000 m mild snow visibility about 1000m These values of visibility are for daylight conditions in night time while using the electric light sources the given values have to be increased by 1000 1500 m recommended values of protective effect are true for fluids with temperature not lower than 60 C on the exit of the sprinkler and fluid waste of not less than 1lt for 1m of the AC surface in case of doubt in defining the conditions freezing spit use the data that applies to the mild rain conditions in terms of protective effect time other types o
Download Pdf Manuals