AC-825IP Hardware Installation and User Guide

image

Contents

1. 23 Figure 15 Normally Closed Supervised Input Double Resistor 24 Figure 16 Connecting Multiple Access Control Panels AC 825IP to the Ax Trax SODVOel crus totos aS detto cubus AT in utes baute cutus tat 33 AC 825IP Hardware Installation and User Guide List of Tables ey ey eee ee List of Tables Table 1 Possible Hardware SettindS ccccccccccccessseceecesseeeeeeeesseeeeeeeeaaeeeees 29 AC 825IP Hardware Installation and User Guide V Notice and Disclaimer Notice and Disclaimer This manual s sole purpose is to assist installers and or users in the safe and efficient installation and usage of the system and or product and or software described herein BEFORE ATTEMPTING TO INSTALL AND OR USE THE SYSTEM THE INSTALLER AND THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES The system must not be used for purposes other than those for which it was designed The use of the software associated with the system and or product if applicable is subject to the terms of the license provided as part of the purchase documents ROSSLARE ENTERPRISES LIMITED and or its related companies and or subsidiaries hereafter Rosslare exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document This manual describes the maximum configuration of the system with t
2. 22 AC 825IP Hardware Installation and User Guide Input and Output Connections SECURITY PRODUCTS Figure 13 Normally Open Supervised Input Double Resistor 2 2K 8 2K Normally Open Switch IN 4 1 5 Normally Closed Supervised Single EOL Resistor Input Connection Connect a 2 2K resistor in series to the input switch contacts A Normally Closed Supervised Input has 3 states Switch Closed Normal State Loop resistance 2 2K Switch Open Abnormal State Loop resistance Infinite open circuit Short circuit across input terminals Trouble State Loop resistance O short circuit Figure 14 Normally Closed Supervised Input Single Resistor 2 2K Normally Closed Switch 4 1 6 Normally Closed Supervised Double EOL Resistor Input Connection Connect a 2 2K resistor in series to the input switch contacts Connect an 8 2K resistor parallel to the input switch contacts A Normally Closed Supervised Input has 3 states Switch Closed Normal State Loop resistance 2 2K Switch Open Abnormal State Loop resistance 10 4K Open circuit infinite loop resistance or short circuit O resistance across input terminals Trouble State AC 825IP Hardware Installation and User Guide 23 Input and Output Connections Figure 15 Normally Closed Supervised Input Double Resistor 2 2K IN Normally Closed Switch 4 2 Inputs Description 4 2 1 Request to Exit Button REX Inp
3. COMMUNICATIONS oou irai ix iu aii a o di a RC 33 TCP IP Network Connection eessssssssssenenenennnns 33 Limited Warranty ioo iiein ecco secus un oes iE cRE SEP REr A iiesas 35 AC 825IP Hardware Installation and User Guide List of Figures Figure 1 List of Figures Sample AC 8251P CONTIQUIATION cece cece cece cee eeneecceeeeeeeeaneeeeeeeeeeas 12 Figure 2 Input Wiring Supervised Inputs cc ceccccceseeeececeeeeeeeeeeesaeeeeeees 13 Figure 3 Door LOCK Falled GlOSQr s uisi sesh saldlabiediceel accylneutetcalavladneneeets 14 Figure 4 Door Lock Failed Open 0 cccccceccccceeeecccceeseeeeeeeeeseeeeeeeesaeeeenes 15 Figure 5 AC 825 IP in the ME 1525 EncloSure ccccccccceecccceeseeeeeeeesaeeeeees 16 Figure 6 AC 825IP Wiring COMMUNICATIONS ceeccceseceecee ee eeeeeaeeeeeeeeeeenans 17 Figure 7 Reader Wiring Wiegand ssssessem 18 Figure 8 Reader Wiring OSDP ssssssssssssseenenes 18 Figure 9 Slot for Expansion Board Attachment 19 Figure 10 Normally Open Input Connection seeesssseeee 21 Figure 11 Normally Closed Input Connection ssseseeeeene 22 Figure 12 Normally Open Supervised Input Single Resistor 22 Figure 13 Normally Open Supervised Input Double Resistor 23 Figure 14 Normally Closed Supervised Input Single Resistor
4. Each AC 825IP access control unit ACU supports up to six doors In Out each with 2 inputs and 1 output and includes four additional auxiliary inputs and two auxiliary outputs The number of supported doors inputs and outputs can be increased by using the onboard 10 pin expansion slot to connect any of the following expansion boards R 805 16 outputs 805 16 inputs D 805 4 door expansion P 805 16 inputs and 8 outputs Driven by Rosslare s powerful flexible and easy to use AxTraxNG software the system provides an ideal modular and expandable solution for commercial and institutional needs It provides seamless integration with Rosslare s range of RFID proximity PIN Proximity amp PIN smart card and biometric readers with Rosslare s selection of RFID credentials The AC 825 IP is ready for installation with a mountable and lockable metal enclosure ME 1525 integrated with a switch power management board charger sounder and control panel Using an onboard Ethernet TCP IP multiple local or remote site door subnetworks can connect to the AxTraxNG Client Server PC software running on Microsoft Windows 7 8 operating systems The AC 825IP platform consists of the following components A AC 825IP networked access controller ME 1525 metal enclosure with a detachable illumination bar Up to 4 A power management board VAC VDC power switch Terminal block removal tool 4x 2 2K and 4 x 8 2
5. 2 Reader 4 IN OUT Door 3 Reader 5 OSDP IN OUT Door 3 Reader 6 OSDP IN OUT Door 4 Reader 1D IN OUT Door 4 Reader 2D IN OUT Door 1 Reader 1 IN OUT Door 2 Reader 2 IN OUT Door 3 Reader 3 IN OUT Door 4 Reader 4 IN OUT Door 5 Reader 5 OSDP IN OUT Door 6 Reader 6 OSDP IN OUT Door 7 Reader 1D IN OUT Door 8 Reader 2D IN OUT Door 9 Reader 3D IN OUT Door 10 Reader 4D IN OUT Use the AxTraxNG software to set the readers for IN or OUT use and to set the data transmission format for each reader The reader s tamper output connects to the access control panel s Reader Tamper input If the reader is interfered with an alarm can be generated The controller activates the LED control for the time the door is open 28 AC 825IP Hardware Installation and User Guide AC 825IP Hardware Settin gs SECURITY PRODUCTS 5 AC 825IP Hardware Settings Access control panels configured as either single reader door or double reader door controllers have two readers IN or OUT Expansion boards attached to the expansion slot of the panel must be contigured the same as the panel single or double door Expansion boards connected via RS 485 standard can be configured independently of the panel When configuring two readers per door the two readers connected to a door must be using the same format OSDP or Wiegand Table 1 Possible Hardware Settings Connectors Description S
6. Door 8 OUT 8 Door 8 OUT 2D Door 9 OUT 3D Door 10 OUT 4D The output can sink current from any power management board see Section 3 3 26 AC 825IP Hardware Installation and User Guide Input and Output Connections Se ee ore e For UL installations the installer must configure the system as fail safe to comply with NFPA National Fire Protection Association regulations 4 4 Card Readers and Keypads Each access control panel can be connected to a maximum of 6 readers or 10 readers when using D 805 A keypad is required for any reader mode that requires PIN code entries such as Card or PIN PIN Only or Card and PIN Secured mode When connecting a reader the following should be defined Scenario Two Readers per Door One Readers per Door Setting Door 1 Reader 1 IN OUT Door 1 Reader 2 IN OUT Door 2 Reader 3 IN OUT Door 2 Reader 4 IN OUT Door 3 Reader 5 OSDP IN OUT Door 3 Reader 6 OSDP IN OUT Door 1 Reader 1 IN OUT Door 2 Reader 2 IN OUT Door 3 Reader 3 IN OUT Door 4 Reader 4 IN OUT Door 5 Reader 5 OSDP IN OUT Door 6 Reader 6 OSDP IN OUT AC 825IP Hardware Installation and User Guide 2 Input and Output Connections When using the D 805 the following should be defined Scenario Two readers per door One readers per door Setting Door 1 Reader 1 IN OUT Door 1 Reader 2 IN OUT Door 2 Reader 3 IN OUT Door
7. short circuit Figure 10 Normally Open Input Connection IN Normally Open Switch 4 1 2 Normally Closed Input Connection A Normally Closed Input has two states Switch Closed Normal State Loop resistance O short circuit Switch Open Abnormal State Loop resistance Infinite open circuit AC 825IP Hardware Installation and User Guide 21 Input and Output Connections Figure 11 Normally Closed Input Connection Normally Closed Switch 4 1 3 Normally Open Supervised Single EOL Resistor Input Connection Connect an 8 2K resistor in parallel to the input switch contacts A Normally Open Supervised Input has 3 states Switch Open Normal State Loop resistance 8 2K Switch Closed Abnormal State Loop resistance O short circuit Open circuit across input terminals Trouble State Loop resistance Infinite open circuit Figure 12 Normally Open Supervised Input Single Resistor 8 2K Normally Open Switch 4 1 4 Normally Open Supervised Double EOL Resistor Input Connection Connect a 2 2K resistor in series to the input switch contacts Connect an 8 2K resistor parallel to the input switch contacts A Normally Open Supervised Input has 3 states Switch Open Normal State Loop resistance 10 4K Switch Closed Abnormal State Loop resistance 2 2K Open circuit infinite loop resistance or short circuit O resistance across input terminals Trouble State
8. AC 825IP Networked Controller Hardware Installation and User Guide ee as 4 raam co sunt aat AC POWER 30S SL N R SECURITY PRODUC IS Copyright 2014 by Rosslare All rights reserved This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and or its related companies and or subsidiaries hereafter ROSSLARE Only ROSSLARE and its customers have the right to use the information No part of this manual may be re produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of ROSSLARE ROSSLARE owns patents and patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give that party or any third party any license to these patents trademarks copyrights or other intellectual property rights except as expressly provided in any written agreement of ROSSLARE ROSSLARE reserves the right to revise and change this document at any time without being obliged to announce such revisions or changes b
9. F Range Operating Humidity O to 85 non condensing 10 AC 825IP Hardware Installation and User Guide Technical Specifications Specification AC 825IP R 805 MECHANICAL SPECIFICATIONS Enclosure Dimensions H x Miao Sie a Salen S 805 D 38305 P 805 W x D 345 x 400 x 10 mm 13 6 x 15 7 x 0 4 in Enclosure Weight 5 kg 11 0 Ib PCBA Dimensions H x W 224 x 164 mm 8 8 x 6 46 in PCBA Weight 400 g 14 1 oz AC 825IP Hardware Installation and User Guide 4 6 kg 10 1 Ib 175 x 85 mm 6 9 x 3 3 in 150 g 5 3 oz AC 825IP Panel Setup 3 AC 825IP Panel Setup Each AC 825IP panel controls 6 or 10 doors with the D 805 3 or 5 doors in double reader per door mode The panels connect together in a network and are controlled by a central server computer running the AxTraxNG software System Figure 1 shows an example setup for a network of AC 825IP access control panels Figure 1 Sample AC 825IP Configuration REX TCP IP m Reader or Keypad fl VAS SIE Paes 12 AC 825IP Hardware Installation and User Guide AC 825IP Panel Setup Sse Wns melee The highlited area indicates the use of OSDP readers and their I O connectivity Note Bushings are needed for any conductors leaving the enclosure through the provided openings 3 1 Input Wiring Supervised Inputs When wiring the AC 825IP for supervised inputs resistors should be placed on the input switch and not
10. Guide 15 AC 825IP Panel Setup 3 4 Power Management Figure 5 illustrates the AC 825IP ACU within the ME 1525 enclosure It is recommended to add a 12 VDC lead acid backup battery in case the power management board fails If the main input is 12 VDC wire it to the power management board which has a load rating of up to 4 A for lock connectivity If 4 A is not sufficient an external power supply should be added according to the electrical requirements For more information refer to Section 4 3 Figure 5 AC 825IP in the ME 1525 Enclosure AC 825IP VAC alin ae 1 4 mm Dual 12 VDC power to locks VAC INPUT POWER VDC OUTPUT POWER POWER MANAGEMENT AC POWER DC POWER 16 AC 825IP Hardware Installation and User Guide AC 825IP Panel Setup SECURITY PRODUCTS 3 5 AC 825IP Wiring Ports Figure 6 presents a detailed view of the access control panel with all it wiring communications Figure 6 AC 825IP Wiring Communications _ _ M M Q TCP IP pm Mn Door 1 oo ilO HLA Door Monitor NC 2 0 m p O S _4 slo a c Rifo i MM E O ma ao 2 7 se Eo v O dio R S D P 805 EXPANSION BOARD um 36 8 se o k a L io m REIO L B lo mi o er 70 E 3 ee O a hilo L B lo M RSDP OSDP Bus a ool espog vod lbo
11. K resistors for the supervised inputs AC 825IP Hardware Installation and User Guide 7 Introduction 1 1 Features The AC 825IP is a powerful and adaptable access control solution with a range of powerful features A Controls 6 doors 4 readers are connected via Wiegand format and 2 are connected via Open Supervised Device Protocol OSDP Controls an additional 4 doors connected via Wiegand when an D 805 is mounted optional A Four IN OUT readers with tamper switch and LED control 12supervised inputs 28 when the S 805 or the P 805 expansions are installed 6 Form C relay outputs rated 5 A 16 when R 805 is installed A Onboard TCP IP communication incorporated bi directional push communication with AxTraxNG server for enhanced data transmission speed and reliability Uses an AES 128 bit encryption between the AC 825IP panel and the AxTraxNG server Supports up to 60 000 users A Supports up to 500 000 history log entries FIFO per ACU Built in sounder for chime bell and siren signals Remote firmware upgrades Removable terminal blocks A real time clock keeps time for up to 2 weeks without power and is backed up by a battery 1 2 AxTraxNG The AxTraxNG software is custom designed to set up manage and supervise all aspects of an access controller s network It offers the following capabilities 1 2 1 Client Server Structure AxTraxNG operates through a dedicated AxTraxNG server c
12. as well as any OSDP readers that may be connected serially to the AC 825IP via RS 485 interface AC 825IP Hardware Installation and User Guide 9 Technical Specifications 2 Technical Specifications Specification AC 825IP R 805 S 805 D 805 P 805 ELECTRICAL SPECIFICATIONS Enclosure ME 1525 ME 1505 Enclosure SMPS Input 90 to 265 VAC 50 60 Hz switch mode power management board Output 12 VDC 4A PCBA Input Power 12 VDC 2 A regulated power management board Battery Charger 12 V sealed lead acid SLA up to 7 Ah OPERATIONAL SPECIFICATIONS Relays 5 A Form C 6 16 N A 4 8 Supervised Inputs 12 N A 16 8 16 Readers Wiegand Format 4 N A N A 4 N A Readers OSDP Format 2 N A N A N A N A Expansion Port 1 N A Connectivity TCP IP OSDP OSDP G Bus OPERATIONAL SPECIFICATIONS AC 825IP only Capacity Up to 60 000 users History Event Log Size Up to 500 000 entries Time Zones and Groups 256 multi segment time zones 64 holidays each holiday can be multiple days Practically unlimited amount of access groups Special Features with Interlock first person delay auto relock scheduled AxTraxNG outputs operation 4 programmable site codes extended unlocked time fully interconnectedness car parking management antipassback per reader between readers Security Modes Normal and Secure ENVIRONMENTAL SPECIFICATIONS Operating Temperature 5D C 10 50 C 23 F to 122 P Range Storage Temperature 25 C to 50 C 13 F to 122
13. der2D Reader3D Reader4D Setup Sate ee ere e Door2 OUT IN Door3 IN OUT Door3 OUT IN Door4 OUT IN Door5 OUT IN Door5 OUT IN OUT 1 O O OOO c ciceielic S455 F lo ui a lw J NNN NNN M MM MR MM NN NN NN NN NN NO ON ONO Door4 IN OUT Door1 IN OUT Door2 OUT IN Door3 IN OUT Door4 OUT IN Door5 IN OUT Door6 OUT IN Door7 IN OUT Doors OUT IN Door9 OUT IN Door10 OUT IN 31 AC 825IP Hardware Settings 5 1 DIP Switch Configuration Currently not used 5 2 Setting AC 825IP Panel Type in AxTraxNG The AC 825IP panel type is defined using AxTraxNG There are two panel types a panel with one reader per each door or a panel with two readers per each door Please refer to the AxtraxNG manual for further details 32 AC 825IP Hardware Installation and User Guide Communications SER eo gm 6 Communications Communication lines are used to upload and download intormation between the AC 825IP panel and the AxTraxNG server using an IP Network 6 1 TCP IP Network Connection The computer running the AxTraxNG server can communicate with the access control panels via an IP network The connection settings are controlled within the AxTraxNG Client software AC 825IP panels connect to the IP network using an onboard network module 6 1 1 LAN and WAN Requirements The devices can be connected to an IP network using any valid network address The following schematic ill
14. eforehand or after the fact Table of Contents 1 1 1 L Do 3 1 3 2 3 3 3 4 3 5 3 6 3 7 4 1 4 2 4 3 4 4 5 1 Du 6 6 1 A Table of Contents miBi inm PRERJES DERE QU CU Os odas ada sad vxax vaa Ead a OVER AK a Ead daa wa ird d dw Ew VM R Uu a MR 7 zs 8 Vp om T T 8 Compatible Red els scs oesedetieont i aem patrius u parv I as mapMe bias an ipd n ra vota 9 Technical Specifications 10 AC 825IP Panel Setup 12 Input Wiring Supervised Inputs ssssessssse 13 Output Wiring RH 14 Open Supervised Device Protocol ccccccccceecccceeeeeeeeeeeeseeeeeeeeaaneees 15 Power Management c 16 POZO WENN POLIS cuit aei icem cnsdak aig dee reai eaei S e 17 Readers and Cable Length seiesudiresurauii ed aut etu dur Fa iade petu El ed dud Edu decies 18 Ep ancon BO IO NET ETT TOT TD 19 Input and Output Connections 21 hot YDE Hn 21 Mpu Descrip iO eeen e aor 24 ROT 26 Card Readers and Keypads cccccccccccccccessesceceeeseeeeceeeesseeeeeesaaeeeees 27 AC 825IP Hardware Settings 29 DIP Switch Configuration castes iret ga Vaart adde rnit p 32 Setting AC 825IP Panel Type in AxTraxNG sssse 32
15. etup Two Readers per Door Outputs Door 1 Lock output OUT 1 Door 2 Lock output OUT 3 Door 3 Lock output OUT 5 General purpose output OUT 2 General purpose output OUT 4 General purpose output OUT6 Inputs Door 1 Request to Exit IN 1A Door monitor input IN 1B Door2 Request to Exit IN 3A Door monitor input IN 3B Door3 Request to Exit IN5A Door monitor input IN5B Readers Reader1 Door1 Door Entry or Exit Reader2 Door1 Door Exit or Entry Reader3 Door2 Door Entry or Exit Reader4 Door2 Door Exit or Entry Reader5 OSDP Door3 Door Exit or Entry Reader6 OSDP Door3 Door Exit or Entry One Reader per Door Outputs Door1 Lock output OUT 1 Door2 Lock output OUT 2 Door3 Lock output OUT 3 Door4 Lock output OUT 4 Door5 Lock output OUT 5 AC 825IP Hardware Installation and User Guide 29 AC 825IP Hardware Settings Connectors Description Inputs Readers Two Readers per Door with 8 Readers D 805 Outputs Inputs Readers 30 Door6 Lock output Door1 Request to Exit Door monitor input Door2 Request to Exit Door monitor input Door3 Request to Exit Door monitor input Door4 Request to Exit Door monitor input Door5 Request to Exit Door monitor input Door6 Request to Exit Door monitor input Reader1 Reader2 Reader3 Reader4 Reader5 Reader6 Door1 Lock output Door2 Lock output Door3 Lock output Door4 Lock output Door4 Lock output Door1 Request to Exit Door1 moni
16. for various functions This function is only available with the S 805 expansion The following should be defined Scenario Two Readers per Door One Reader per Door Setting IN 2A IN 2B IN 4A IN 4B IN 6A IN 6B no general purpose inputs available General purpose inputs are suitable for most uses For example they might be used to detect tampering to activate alarm sensors or to monitor a power management board failure General purpose inputs functions when using S 805 or D 805 Unit S 805 P 805 D 805 Expansions IN1S to IN16S INTP to IN16P IN2C IN2D IN4C IN4D AC 825IP Hardware Installation and User Guide 25 Input and Output Connections 4 3 Outputs Rosslare Security recommends the use of suppression diodes for all outputs that activate an inductive load 4 3 1 Door Lock There are two types of door locking devices Fail open fail secure Fail close fail safe The following should be defined Scenario Setting Two readers per door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 5 One reader per door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 3 Door 4 OUT 4 Door 5 OUT 4 Door 6 OUT 6 Door outputs when using D 805 Scenario Setting Two Readers per Door Door 1 OUT 1 Door 2 OUT 3 Door 3 OUT 5 Door 4 OUT 1D Door 5 OUT 3D One Reader per Door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 3 Door 4 OUT 4 Door 5 OUT 5 Door 6 OUT 6 Door 7 OUT 71D
17. he maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent non compliance damage or injury The text images and graphics contained in the manual are for the purpose of illustration and reference only n no event shall manufacturer be liable for any special direct indirect incidental consequential exemplary or punitive damages including without limitation any and all damages from business interruption loss of profits or revenue cost of capital or loss of use of any property or capital or injury A All graphics in this manual are for reference only some deviation between the image s and the actual product may occur A All wiring diagrams are intended for reference only the photograph or graphic of the PCB s are intended for clearer illustration and understanding of the product and may differ from the actual PCB s 6 AC 825IP Hardware Installation and User Guide I n t rod u cti O n Sse ES ERCSIEJUI E ES 1 Introduction The AC 825IP is an advanced networked access controller and is the backbone of a medium scale to high scale security system that can handle up to 60 000 users and 500 000 events
18. l Setup There are four types of expansion boards as follows 20 R 805 The R 805 is an optional expansion board that adds 16 outputs to the access control panel S 805 The S 805 is an optional expansion board that adds 16 supervised inputs to the access control panel D 805 The D 805 is an optional door expansion board that adds 4 reader inputs 4 outputs Form C 5 A and 8 supervised inputs to the access control panel P 805 The P 805 is an optional expansion board that adds 16 supervised inputs and 8 outputs to the access control panel AC 825IP Hardware Installation and User Guide Input and Output Connections SECURITY PRODUCTS 4 Input and Output Connections This chapter describes the AC 825IP access control panel s input and output connections 4 1 Input Types There are four input types Normally Closed N C Normally Open N O Single EOL resistor A Double EOL resistor Supervised inputs have three states Normal A Abnormal Trouble The Trouble state is caused by either tampering with the input circuit or by a faulty hardware installation Once an input is configured as a supervised input add a resistor of 2 2K 8 2K or both on the input circuit See the following diagrams 4 1 1 Normally Open Input Connection A Normally Open Input has 2 states Switch Open Normal State Loop resistance Infinite open circuit Switch Closed Abnormal State Loop resistance O
19. omputer which communicates with the access control panels and their expansions to serve an unlimited number of network clients The server also runs the system s SQL database which contains settings and definitions for access control across the entire facility System users can define new users and credentials and control access permissions The system includes tools for database backup input and export of previous configurations and automatic backup on a periodic basis AxTraxNG supports all panel types and offers scalability and flexibility in addition to a range of advanced control features 8 AC 825IP Hardware Installation and User Guide I n t rod u cti O n Sel ns PREDRUETS 1 2 2 Configurable Links The system s configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm based on a selected input This allows easy integration with other access systems such as intruder alarms CCTV systems and License Plate Recognition LPR AxTraxNG can also define a selected set of operations which are defined in contigurable links when a panel registers a specified user or a group of users This can be useful for example in access control systems The system can assign users with counters allowing a limited number of entries to each panel 1 3 Compatible Readers The AC 825IP ACU provides support for most of the Wiegand formats such as 26 bit 30 bit 32 bit 35 bit and 36 bit
20. on the terminal block Figure 2 presents a view of the inputs and their connection options Figure 2 Input Wiring Supervised Inputs Readers Inputs amp Outputs o Request to Exit e induj Door Monitor Switch t Indu OSDP Readers Black Auxiliary Auxiliary Input 5A Input 6A AC 825IP Hardware Installation and User Guide 13 AC 825IP Panel Setup For more details on reader connectivity refer to Figure 7 and Figure 9 in Section 3 5 3 2 Output Wiring Figure 3 and Figure 4 illustrate wiring for two main types of 12 VDC electrical release mechanisms Other electrical devices can be switched using the voltage free relay contacts Figure 3 Door Lock Failed Close gt COM out1 AEL E VDC OUTPUT POWER POWER MANAGEMENT FTN N u T AV aim ne DC POWER I on 14 AC 825IP Hardware Installation and User Guide AC 825IP Panel Setup SECURITY PRODUCTS Figure 4 Door Lock Failed Open p COM out1 1 4 AC 825IP Dual 12 VDC power to locks VDC OUTPUT POWER POWER MANAGEMENT CIN i uw T VAS aim Anca DC POWER T si 3 3 Open Supervised Device Protocol OSDP allows connecting control panels with various peripheral devices card readers control panels and other security management systems while unlocking the potential of the onboard computing resources within the system Each panel can connect to up to 2 readers via OSDP AC 825IP Hardware Installation and User
21. ooo0oo0 pod 8 9 GBuws e cw e x ar to R S D P 805 Power IN Aux 1 Aux 2 12 VDC p The USB G Bus ports and DIP switches are currently not functional gt Note AC 825IP Hardware Installation and User Guide 17 AC 825IP Panel Setup 3 6 Readers and Cable Length Readers are supplied with cables having a limited length The color of the cable cover represents the cable s functionality according to the Wiegand and OSDP standards Figure 7 and Figure 8 Figure 7 Reader Wiring Wiegand Jopeay If you wish to extend the cable distance make sure you use the correct cable according to the cable color Some readers are not supplied with a cable Please refer to the reader s manual for connecting it to the relevant reader port Note Refer to the reader specifications for the maximum cable length typically 150 m with an 18 AWG cable 18 AC 825IP Hardware Installation and User Guide AC 825IP Panel Setup SECURITY PRODUCTS 3 7 Expansion Boards The AC 825IP control panel provides a slot for expansion boards Figure 9 Figure 9 Slot for Expansion Board Attachment E 6000 Hoppe 4 e a e a e e e e x a e e A i m o x e a e Mal e e e 60005090 0069 000 v A J Pub Q AC 825IP Hardware Installation and User Guide 19 AC 825IP Pane
22. resecurity com Fax 852 2795 1508 support apac rosslaresecurity com China Rosslare Electronics Shenzhen Ltd United States and Canada Shenzhen China Rosslare Security Products Inc Tel 86 755 8610 6842 Southlake TX USA Fax 86 755 8610 6101 Toll Free 1 866 632 1101 support cn rosslaresecurity com Local 1 817 305 0006 India Fax 1 817 305 0069 Rosslare Electronics India Pvt Ltd Tel Fax 91 20 40147830 Europe Mobile 91 9975768824 Rosslare Israel Ltd sales in rosslaresecurity com Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com support na rosslaresecurity com ROSSLN SECURITY PRODUCTS www rosslaresecurity com 0706 0960579 00 TUVRheinland gee TA CERT Queer i50 1 wtu V o SA s S e ENISO13485 Ro H 5 E T VAheinisna E z gt COMPLIANT Props ou
23. tor input Door2 Request to Exit Door2 monitor input Door3 Request to Exit Door3 monitor input Door4 Request to Exit Door4 monitor input Door5 Request to Exit Door5 monitor input Reader1 Reader2 Reader3 Setup OUT 6 IN 1A IN 1B IN 2A IN 2B IN 3A IN 3B IN 4A IN 4B IN 5A IN 5B IN 6A IN 6B Door1 IN OUT Door2 IN OUT Door3 IN OUT Door4 IN OUT Door5 IN OUT Door6 IN OUT OUT 1 OUT 3 OUT 5 OUT 1D OUT 3D IN 1A IN 1B IN 3A IN 3B IN 5A IN 5B IN 1C IN 1D IN1C IN1D Door1 IN OUT Door1 OUT IN Door2 IN OUT NNN NNN M MR Om iON OO AC 825IP Hardware Installation and User Guide AC 825IP Hardware Settings Connectors Description One Reader per Door with 8 Readers D 805 Outputs Inputs Readers AC 825IP Hardware Installation and User Guide Reader4 Reader5 OSDP Reader6 OSDP Reader1D Reader2D Reader3D Reader4D Door1 Lock output Door2 Lock output Door3 Lock output Door4 Lock output Door5 Lock output Door6 Lock output Door7 Lock output Door8 Lock output Door9 Lock output Door10 Lock output Door1 Request to Exit Door2 Request to Exit Door3 Request to Exit Door4 Request to Exit Door5 Request to Exit Door6 Request to Exit Door7 Request to Exit Door8 Request to Exit Door9 Request to Exit Door10 Request to Exit Reader1 Reader2 Reader3 Reader4 Reader5 OSDP Reader6 OSDP Reader1D Rea
24. ustrates the connection of a single AC 825IP to a computer via a LAN network The maximum distance from the Ethernet port of the panel to the LAN connection is 328 ft 99 97 m When the IP connection is implemented over a WAN it is then possible to communicate with the panel via the Internet with an AxTraxNG client allowing multiple access controllers worldwide to be reached Figure 16 Connecting Multiple Access Control Panels AC 825IP to the AxTraxNG Server BAx lt TRAx lt NG Access THE SUTUNE TCP IP TCP IP VAS all aes E E il AC 825IP Hardware Installation and User Guide 33 Communications Before connecting a panel by an IP connection for the first time the AxTraxNG software must configure the device Settings are then stored in the device see the Ax7raxNG Software Manual for further details 34 AC 825IP Hardware Installation and User Guide Limited Warranty SECURITY PRODUCTS A Limited Warranty The full ROSSLARE Limited Warranty Statement Is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them AC 825IP Hardware Installation and User Guide 35 OF Asia Pacific Middle East Latin America Africa Rosslare Latin America Rosslare Enterprises Ltd Buenos Aires Argentina Kowloon Bay Hong Kong Tel 54 11 4001 3104 Tel 852 2795 5630 support la rossla
25. ut Use the REX Input to open a door directly Typically the REX input is connected to a Normally Open push button that is located inside the premises The push button is generally located in an easy to access position and opens a door without reading any credential Scenario Setting Two Readers per Door Door 1 IN 1A Door 2 IN 3A One Reader per Door Door 1 IN 1A Door 2 IN 2A Door 3 IN 3A Door 4 IN 4A Door 5 IN 5A Door 6 IN 6A REX Inputs functions when using D 805 Scenario Setting Two Readers per Door Door 4 IN1C Door 5 IN3C One Reader per Door Door 7 IN1C Door 8 IN2C Door 9 IN3C Door 10 INAC 4 2 2 Door Monitor Input The Door Monitor Input typically connects to a Normally Closed door sensing micro switch for door status monitoring Using Door Monitor enables many advanced options such as door forced alarm door held open warnings interlocking doors and more Scenario Setting Two Readers per Door Door 1 IN 1B Door 2 IN 3B Door 3 IN 5B 24 AC 825IP Hardware Installation and User Guide Input and Output Connections One Reader per Door Two Readers per Door Door 4 INTD One Reader per Door 4 2 3 General Purpose Inputs Door 1 IN 1B Door 2 IN 2B Door 3 IN 3B Door 4 IN 4B Door 5 IN 5B Door 6 IN 6B Door 5 IN3D Door 7 IN1D Door 8 IN2D Door 9 IN3D Door 10 IN4D ae Si EGET ES These are free inputs that can be used