1. Code Electric power supply out of the operation range RESET associated symbol Call the Service Centre Function codes Code Frost protection function central heating circuit ON Wait for the completion of the operation Code Frost protection function D H W circuit ON RS version only with connection to a remote storage cylinder Wait for the completion of the operation Code Legionella Prevention Function RS version only with connection to a remote storage cylinder Wait for the completion of the operation Code F33 System purging function ON Wait for the completion of the operation RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 6 USER INSTRUCTIONS 8 Switching OFF the boiler 0 To switch the boiler OFF press INFO button the symbol Q appears on the display The frost protection system the circulating pump inactivity protection and 3 way valve inactivity protection functions remain enabled HS version only with connection to a remote storage cylinder gt If the boiler was previously ON it is switched OFF and the fan overrun and pump overrun functions are enabled N B If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity and gas and draining the heating system Leave the boiler in OFF position leaving the electricity and gas supplies connected and conse
2. Heating technology since 1959 User Manual for model HK 100 Premix condensing system boiler CE 0694 RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 Techn ical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH INDEX 1 General warning page 1 2 Control Panel 2 3 Starting up the boiler 3 4 INFO Menu 5 Boiler functioning modes 4 6 Filling the system 5 T Diagnostics Error and function codes 5 8 Switching OFF the boiler 6 9 Frost Protection f 10 Maintenance f 11 Recycling T USER INSTRUCTIONS BOILER OPERATING INSTRUCTIONS 1 General warning A Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet A The installation first start up regulation and maintenance operations must be carried out exclusively by qualified personnel e g Radiant authorised Service Centres Incorrect installation can cause damage to property and injury to persons or animals for which the manufacturer will not be held responsible During the installation the technician must carry out the following checks m The data on the data plate must correspond to that of the mains supply networks gas electricity water m The boiler must be regulated according to its designed use and performance m The flue gas exhaust and combustion air intake system must be correctly installed and operational m The exhaust gas discharge and ventilation systems must comply with
3. temperature The heating temperature is regulated by using 2 and buttons of Heating temperature setting page 3 fig 1 pos 1 e Pressing button reduces the temperature e Pressing button increases the temperature The range of temperature settings for the central heating runs from a minimum of 30 C to a maximum of 80 C 25 C 45 C for under floor heating systems Regulating the D H W temperature RS version only with connection to a remote storage cylinder The D H W temperature is regulated by using Z and Z buttons symbol side page 2 fig 1 pos 5 e Pressing button reduces the temperature e Pressing button increases the temperature The range of temperature settings for the D H W temperature runs from a minimum of 35 C to a maximum of 60 C RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 4 USER INSTRUCTIONS 6 Filling the system In order to restore the water pressure of the system open the external filling loop valve and check by means of a pressure gauge that the pressure of the system reaches 1 2 1 5 bar On completion close the external filling loop valve After the water pressure is restored a purging cycle of 2 minutes is automatically performed by the boiler The function code F33 will appear on the display The starting of the boiler is enabled only once the purging cycle has been completed T Diagnostics Error
4. the requirements of national and local standards regardless of whether the boiler is installed indoors outdoors or in its own cabinet see section Reference standards User general warnings If there is any doubt as to whether the appliance has been tested by an authorised technician do not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALL Y QUALIFIED PERSONNEL 2 Should any part of the boiler freeze up do not attempt to light it under any circumstances but instead call the Service Centre immediately Theappliance s combustion system must be checked every two years This check includes testing the efficiency of the boiler and must be carried out by authorised personnel possessing the qualifications as required by current law 2 Do not obstruct the ventilation openings in rooms where there are gas burning appliances installed boiler cooker etc 2 Do not allow the appliance to be used by persons including children with reduced physical sensory mental capabilities or with lack of experience and knowledge unless they have been viewed or educated on the use of the appliance by the person responsible for its safety or anyone unfamiliar with its operation The installation operation and maintenance manual forms an integral and essential part of the product and must be kept near the appliance always If you smell gas gt DO NOT ACTIVATE ANY ELECTRIC SWITCHES
5. 9 0721 9079279 e mail info radiant Internet http www radiant it THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS E OEALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER INCLUDING ELECTRONIC MECHANICAL PHOTOCOPIES RECORDINGS OR ANY OTHER MEANS WITHOUT THE COMPANY S PRIOR WRITTEN APPROVAL RADIANT Heating technology since 1959
6. TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM gt CLOSE ALL GAS TAPS AND VALVES CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 1 2 USER INSTRUCTIONS Control panel Control panel Key HEATING TEMPERATURE SETTING BUTTONS INFO BUTTON PRESS ONCE TO DISPLAY TEMPERATURES AND INFO see 2 10 INFO menu display KEEP INFO BUTTON PRESSED FOR 5 SECONDS in OFF MODE TO DISPLAY THE LAST 5 ERRORS MODE SELECTION BUTTON SUMMER ONLY WINTER ONLY SUMMER WINTER OFF RESET BUTTON ERROR RESET FLUE TEST FUNCTION ACTIVATION CHIMNEY SWEEPER KEEP IT PRESSED FOR 7 SECONDS DOMESTIC HOT WATER TEMPERATURE SETTING BUTTONS RS version only with connection to a remote storage cylinder KEEP BUTTONS AND PRESSED FOR 5 SECONDS TO ACTIVATE THE DISPLAY BACKLIT MODE FOR A CONTINUOUS PERIOD OF 10 MINUTES TERMINAL BLOCK FOR EXTERNAL WIRING LCD DISPLAY LCD display icons key 1 2 3 10 11 12 13 14 15 RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 PARAMETER NUMBER INFORMATION PARAMETERS PROGRAMMING MODE ON SOLAR PCB CONNECTION INFORMATION SOLAR PANEL TEMPERATURE DISPLAY d6 SOLAR PUMP ON STORAGE CYLINDER LOW LEVEL TEMPERATURE VISUALI
7. ZATION d7 STORAGE CYLINDER HIGH LEVEL TEMPERATURE VISUALIZATION d8 RS version only with connection to a remote storage cylinder OUTDOOR TEMPERATURE SENSOR CONNECTED OUTDOOR SENSOR TEMPERATURE DISPLAY d2 TEMPERATURE SET POINT PARAMETER VALUE INFORMATION OPEN THERM COMPONENTS COMMUNICATION CONNECTED REMOTE CONTROL ZONE MANAGEMENT CONTROL BOX WATER LOW PRESSURE INFORMATION FLAME PRESENCE ON 3 POWER STEPS D H W MODE ENABLED RS version only with connection to a remote storage cylinder RESETTABLE ERROR DISPLAY OFF MODE NOT RESETTABLE ERROR DISPLAY HEATING MODE ENABLED oB al O Page ar gt M seve rsr S gt A A i 53 230 V 50 Hz L V d 1 23 4 5 6 Fig 1 4 5 6 M 3 8 pB OU o 2 FIF PF e 2 1 7r74 PHB OI JL I 03 10 D seewce x 15 11 ux 13 12 33 gt 33 lt 66 gt 66 lt 100 LJ 96 jp BP Fig 3 USER INSTRUCTIONS 3 Starting up the boiler e Check that the boiler is po
8. and function codes This paragraph contains a list of error Exx and function IFXx codes that the boiler may generate on the display together with the relative indications and the operations that the user can carry out to reset the boiler Error codes Code lonisation malfunction RESET associated symbol Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply Press Reset button on the control panel to reset the error When the error code on the display disappears the boiler will restart automatically A If the problem persists Call the Service Centre Code Safety Thermostat tripped RESET associated symbol Press Reset button on the control panel to reset the error When the error code on the display disappears the boiler will restart automatically A If the problem persists Call the Service Centre Code Thermo fuse 102 C tripped RESET associated symbol Call the Service Centre 1 Code Water Pressure Switch Tripped E low associated symbol Check the water pressure in the central heating circuit The reading on the pressure gauge M see fig 2 located on the lower part of the boiler must not be less than 1 2 bar fthe pressure is less than 1 2 bar top up the system as described in paragraph Filling the system When the error code on the display disappears the boiler will restart automaticall
9. n to SUMMER mode press the MODE SELECTION button wor page 2 fig 1 pos 3 The boiler will only work for the D H W system the heating system is disabled The SUMMER mode setting of the boiler is signalled by the symbol fil lit continuously on the control panel The automatic ignition system will light the burner every time there is a domestic hot water demand In this case the symbol will flash on the control panel WINTER mode To switch boiler operation to WINTER mode press the MODE SELECTION button page 2 fig 1 pos 3 The boiler will only work for the Heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burner every time there is a room heating demand In this case the symbol will flash on the control panel SUMMER WINTER mode RS version only with connection to a remote storage cylinder Qi To switch boiler operation to SUMMER WINTER mode press the MODE SELECTION button non page 2 fig 1 pos 3 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by symbols tl lit continuously on the control panel The automatic ignition system will light the burner every time there is a room heating or domestic hot water demand The functioning is signalled by the symbols flashing continuously on the control panel Regulating the heating
10. quently the frost protection function 9 Frost Protection The boiler is protected from freezing by electronic board settings and special functions that provide the starting of the burner to heat all the interested parts when their temperature drops below the minimum preset values This function is enabled if the boiler is electrically power supplied the gas supply is open the system pressure is that required the boiler is not locked out AN In case of boiler parts locked out because of freezing do not switch the boiler ON and immediately call the Service Centre 10 Maintenance In order to ensure that the boiler operates efficiently and safely it is recommended that the appliance is inspected by a suitably competent technician at least once a year A regular maintenance is always source in management system savings 11 Recycling The appliance packaging is mainly made of recyclable materials The symbol indicates the inability to dispose of The appliance and all its accessories must be this product as domestic waste disposed of appropriately differentiated The correct disposal of this product will help to in compliance with the relevant standards prevent potential negative consequences for the environment and people health RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 T RADIANT BRUCIATORI s p a Via Pantanelli 164 166 61025 Loc Montelabbate PU Tel 39 0721 9079 1 fax 3
11. wer supplied and that the gas feed valve placed at the bottom of the boiler is open mm A e Switch on the boiler by using MODE SELECTION BUTTON and select the functioning mode required 4 INFO Menu display Press the INFO Button to display the boiler data Once pressed the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display Use and buttons of Heating Temperature setting to scroll the list of available data Press the lt V INFO button to exit the display mode The list of available display data is the following Parameter Icon Description S DHW sensor temperature RS version only with connection to a remote storage i cylinder a jfmsmd SSCS as __ Low temperature crout sensor only with Zone PCB GRADO connected Heating return sensor temperature only with PWM conta electronic credar da e d Solar storage cylinder temperature low level only with Solar PCB connected Solar storage cylinder temperature high level only with Solar PCB connected de d E Solar storage cylinder temperature extra only with Solar PCB connected RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 3 USER INSTRUCTIONS 5 Boiler functioning modes SUMMER mode RS version only with connection to a remote storage cylinder To switch boiler operatio
12. y A If the problem persists Call the Service Centre Code Heating Sensor malfunction SERVICE associated symbol Call the Service Centre Code D H W sensor malfunction SERVICE associated symbol RS version only with connection to a remote storage cylinder Call the Service Centre Code Fan malfunction SERVICE associated symbol Call the Service Centre RK 100 RAD ING MAN UT 1311 1 DIGITECH CS MIAH4 5 USER INSTRUCTIONS Code Inadequate circulation SERVICE associated symbol Call the Service Centre Code E21 General malfunction inside the printed circuit board SERVICE associated symbol Switch off the power supply at the main switch and then switch it on again When the error code on the display disappears the boiler will restart automatically A If the problem persists Call the Service Centre Code E22 Parameter programming request SERVICE associated symbol Switch off the power supply at the main switch and then switch it on again When the error code on the display disappears the boiler will restart automatically A If the problem persists Call the Service Centre Code E35 Flame detection malfunction RESET associated symbol Press Reset button Y on the control panel to reset the error When the error code on the display disappears the boiler will restart automatically A If the problem persists Call the Service Centre