1. Instant Mode can be activated at any time after the system has been armed The red Armed light will flash rapidly while in the Instant Mode Easy Exit Optional Easy Exit programmed LI YEs L No Your System may have been programmed to allow Easy Exit which allows a user to exit the premises with the system armed By pressing menu followed by 0 the protection is removed from the Exit Entry zone for 3 minutes This will allow for example an early morning commuter to exit the house in the morning without having to disarm and rearm the system waking the family Arming with a System Trouble Present TROUBLE is lit If the GEM P800 has a system trouble present TROUBLE A will be lit and the keypad sounder pulsing If you cannot immediately clear the trouble the system can still be armed Simply press followed by to view the trouble Press to view any other troubles and exit the TROUBLE mode when done Enter your User Code and press to arm the system For more information refer to page 12 Note System troubles should be repaired as soon as possible EMERGENCY CONDITIONS Crt E Fire Emergency Enabled No _ Yes _ L salti x Auxiliary Emergency Enabled NoL_ Yes _ RULES Police Emergency Enabled Yes _ No Ambush Alarm Enabled Yes _ No _ Emergency Buttons 7F 8A 9P j The three sets of emergency buttons if programmed are always active whether the
2. Exit Entry door When the system is subsequently disarmed all bypassed zones will be reset ready to be armed again If it is necessary to bypass any inoperative zone s it is important to have the zone s repaired as soon as possible A bypassed zone does not provide any protection compromising system security ARMING STAY PROTECTING YOURSELF AT HOME Arming in STAY Mode Arm with Interior Zones Bypassed 1 Interior Zones when bypassed allow free movement within the home while the protection of armed perimeter Zones is maintained Before arming your system make sure the green Status light is ON This indicates that all of your protective zones are secure If any zones are open the corresponding zone number will be lit Secure those zones before proceeding 2 Enter your User Code and press StA The green Status light will go out and the red Armed light will light At this point you can stay within the premises or since the Exit Delay is operating you can leave the premises during the Exit Delay time Easy Arm STAY The optional Easy Arm STAY feature allows the system to be armed by simply pressing and holding down Stay for 3 seconds This will allow the easy arming of the system by someone who is not a regular system user Instant Protection After arming STAY above press and hold StA to cancel the Entry delay activating the Instant mode This is typically done in the evening when all family members are home for the night
3. FIRE amp should go out in approximately 30 seconds If it does not go out press again in a few minutes If it still does not go out call for service Abort Delay Ask your installer which of your zones have Abort Delay a delay that enables you to reset the system before it communicates to the central station Your system has a SIA CP 01 required Abort Delay of 30 seconds It may be removed or increased up to 45 seconds at your op tion by consulting with your installer FIRE PROTECTION Preparing a Fire Escape Plan Even with the most advanced fire alarm system adequate protection requires an escape plan To prepare your plan draw floor plans of your building space is provided on the next page Show two exits a front or back door and a window from each room Make sure each window works You may need a special fire escape ladder ifthe window is high up Write down your outside meeting place Would You Like More Safety Information Family Rehearsal Reheatse each olthetollowing activites For more information on home fire detection 1 Everyone in his room with the doors closed burn safety and home fire safety write to 2 One person sounds the alarm i i 3 Each person tests his door National Fire Protection Association 4 Pretend that the door is hot and use the alternate escape exit Public Affairs Dept 05A 5 Everyone meets outdoors at the assigned spot Batterymarch Plaza Quincy MA 02269 Important Read Ca
4. bell or siren to sound for 2 seconds This will also initiate a test of your battery to make sure it is adequately charged The P800 also performs an automatic battery test very 24 hours Access Output If programmed pressing menu followed by C3J will activate the Access Output which may be configured to open a door strike turn on lighting or activate some other special feature your installer has provided Display System Trouble Pressing meny followed by when TROUBLE is lit will cause the system to display any current system troubles Pressing STAY will exit the Display System Trouble Mode Chime Mode On Off Pressing meny followed by C amp J will activate deactivate the door chime Activating this feature will cause any door to beep the keypad sounder when it is opened Program Mode Pressing menu followed by will enable the Program Mode which will allow you to program and erase user codes see Programming user codes page 14 Entry Exit Annunciation Pressing meny followed by LF will deactivate activate the Entry Exit Annunciation depending on its present state By deactivating the sounder on a keypad installed in a bedroom for example you will only turn off that keypad s sounder for Entry Exit Annunciation All other keypads on the system will still sound normally 11 A SYSTEM TROUBLES The GEM P800 is constantly monitoring its own components as well as all critical services such as
5. lights will flash and the keypad will beep 4 times You are now in the User Program mode Zones 1 through 8 will light to indicate any User Codes presently programmed Programming Reprogramming User Codes 1 Press the User number to be programmed For example press to program the User 2 code The keypad will beep 2 times and the corresponding Zone will flash to indicate the user number you are about to program 2 Press in the 4 digits of the new User 2 code the keypad will beep 4 times 3 If there are more user codes to be programmed return to step 1 above otherwise go to Exiting the User Program Mode below Erasing a User Code 1 Press the User number to be erased The keypad will beep 2 times and the corresponding Zone light will flash to indicate the user number you are about to erase 2 Press Awy The zone light will go out to indicate that the user code has been erased 3 If there are more user codes to be erased return to step 1 above otherwise go to Exiting the User Program Mode below Exiting the User Program Mode When you are done programming or erasing User codes press RESET to Exit the User Program Mode 14 GLOSSARY Ambush Code In the event that you are forced by an intruder to disarm your system this special code can be used to disarm the system and simultaneously send a silent alarm to Central Station If your system has the Ambush feature enabled the code assigned as the User 8 code will function as yo
6. to indicate AC Light will light to indicate sounder will beep when system is in a Fire Alarm that the corresponding Zone is open and will that AC Power is present Condition See Silencing a fire Alarm Page 8 flash to indicate a Zone in alarm Press after a valid User Code Trouble Light will light and the Keypad sounder will pulse to indicate that a system trouble is present See System troubles Page 12 Status Light will light when all zones are secure ee and system is ready to be Armed p bypassed Armed Light will light when system is Armed i causes the and will flash when system is in Alarm entered cade or selected l function to be Press veny followed by the corresponding executed Function number to enable special functions and options See Special Functions Page 11 Numerical Emergency Keys Press simultaneously Away Allows To Bypass a zone press and the zone me 1 9 0 to signal an emergency condition arming with sed to gas number to be bypassed and then Arm system re Press C7 for Fire Emergency interior Codes Zone 8AJ _x_ for Auxiliary Emergency or protection on Press RESET to reset Fire Zone clear miss Cerj CJ for Police Emergency Programmable entered codes reset Alarm Memory etc 4 ARMING AWAY SETTING THE ALARM WHEN LEAVING Arming in AWAY Mode 1 Before arming your system make sure the green
7. trouble can be cleared when the service is restored by pressing MENU followed by again to view the trouble and and then pressing STAY to exit Otherwise call installing company for service 1 Beep Telephone Line Cut The telephone line has failed If telephone service has been temporarily interrupted the trouble will clear it is when restored Otherwise call installing company for service 12 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service A SYSTEM TROUBLES Keypad Beeps or Zone light System Trouble Action A Flashes ON Condition Fire Trouble A problem has been detected in the Fire Circuit Call installing company for service 2 Beeps 3 Wireless Receiver A problem has been detected with the wireless receiver Call installing company for Trouble service Wireless Receiver Jam A problem has been detected with a wireless receiver Call installing company for service 3 Beeps 1 8 Wireless Transmitter The battery in a wireless transmitter is low and should be replaced This transmitter is Low Battery on the zone corresponding to the number of the lit zone light The replacement battery for the GEM Trans2 door window transmitter GEM PIR motion detector and GEM GB glass break detector is the Duracell DL123A 3 volt lithium 2 required for the GEM PIR and GEM GB The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with the same t
8. your code press Reset and re enter the code followed by Alarm Indication Silencing an Alarm If the Red Armed light is flashing rapidly an alarm occurred while you were away Proceed with caution For your own protection leave immediately and call authorities from a neighbors phone In the event that the system goes into alarm due to a violated burglary zone the siren and the keypad sounder will activate and the number of the zone in alarm will flash in the display To silence the system enter your User code followed by fi The keypad sounder and siren will silence but the zone in alarm will continue to flash Press Reset to reset this alarm memory Silencing a Fire Alarm In the event that the Fire alarm activates due to a violated smoke or fire detector the bell or siren will sound a distinct pulsating tone FIRE amp onthe keypad will be flashing and the keypad sounder will emit a pulsing tone If a Fire Alarm does occur 1 Ifafire is in progress evacuate the premises immediately Call the Fire Department from an outside phone 2 If there is no evidence of a fire enter your User Code followed by i The bell or siren will silence and FIRE will stop flashing but will still be lit Determine which device went into alarm If you are protected by smoke detectors the light on the active detector will be lit Once it is determined which smoke detector is in alarm press to reset the fire zone 4 Ifthe Fire zone has reset properly
9. AC power and the telephone line to insure that it is always ready to provide the protection for which it was designed When a system trouble does occur it will caution you by lighting the TROUBLE A light and beeping the keypad buzzer If you cannot immediately clear the system trouble the system can still be used Simply press Meny followed by to view the trouble as described below and then arm the system To determine the nature of the trouble press MENU followed by C2 1 count the number of keypad beeps and observe the number of the illuminated zone Refer to the following table to determine the cause of the trouble If there is more than one trouble to view pressing STAY will scroll to the next trouble and then exit the TROUBLE A mode if there are no more troubles to view Keypad Beeps or Zone light System Trouble Action A Flashes ON Condition 1 Beep 1 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for service 1 Beep 2 Low Battery If there has been a recent power failure the battery may be partially depleted and must be recharged by the control panel If the trouble does not go away in 24 hours call installing company for service 1 Beep 3 Communication The system was not able to report to central station If this is due to a temporary Failure interruption in the telephone service the
10. OPERATING GUIDE for your GEM K800 KEYPAD GEMINI COMPUTERIZED SECURITY SYSTEM NAPCO 2003 01285 9 03 INTRODUCTION Congratulations on your purchase of an advanced GEMINI P800 Series Security System Meticulously developed by a leading manufacturer of state of the art security products this system will provide you with unprecedented peace of mind amp incorporates some of the most sophisticated features available today Above all it has been designed an extra step to provide all those operating it with very easy intuitive use Please carefully review the information contained in this manual so that you and all potential users of the system familiarize yourselves with its operation and can therefore take full advantage of GEMINI s many convenient features and amenities Your system consists of a control panel a computer housed within a white metal panel enclosure one or more GEMINI Decorator Keypads for controlling the system and various security detection devices These detection devices are divided among separate areas known as zones set up throughout your premises Each zone number corresponds to a Zone light on your Keypad s display area When a zone s number is ON or lit it indicates that one or more detection device s assigned to that area are active or open For example if Zone 1 is the front door and it is open the 1 on the keypad display will be lit If zone 2 is a motion detector and t
11. Status light is ON This indicates that all of your protective zones are secure If any zones are open the corresponding Zone number will be lit Secure these zones before proceeding If any zones cannot be secured see Bypassing zones below 2 Enter your user code and press Away The green Status light will go out the red Armed light will light e If you make a mistake entering your code press RESET re enter your code and press Away elf FIRE amp is lit the Fire zone has not been properly reset Press RESET enter your user code and press AWAY See Silencing a Fire Alarm page 8 3 Leave the premises through the Exit Entry door If the keypad gives a steady tone you have taken too long Enter your code again to disarm system and begin again at step 1 above Easy Arm AWAY The optional Easy Arm AWAY feature allows the system to be armed by simply pressing and holding down Away for 3 seconds This will allow the easy arming of the system by someone who is not a regular system user Selectively Bypassing Zones If an open zone cannot be immediately fixed it can be left unprotected or bypassed while the rest of the system is Armed To bypass a zone 1 With the panel disarmed press Brass followed by the number of the zone to be bypassed The bypassed zone s number will flash slowly Enter your user code and press Awa The green Status light will go out and the red Armed light will light N 3 Leave the premises through the
12. TEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ADDITIONALLY THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO Any action for breach of warranty including but not limited to any implied warranty of merchantability must be brought within the six months following the end of the warranty period IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT In case of defect contact the security professional who installed and maintains your security system In order to exercise the warranty the product must be returned by the security professional shipping costs prepaid and insured to NAPCO After repair or replacement NAPCO assumes the cost of returning products under warranty NAPCO shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or removed NAPCO will not be responsible for any dismantling reassembly or reinstallation charges This warranty contains the entire warranty It is the sole warranty and any pr
13. Y PROTECTING YOURSELF AT HOME EMERGENCY CONDITIONS TURNING OFF THE ALARM DISARMING WHEN RETURNING For Service Call FIRE PROTECTION FUNCTION MENU Entry Delay SYSTEM TROUBLES PROGRAMMING OPTIONAL Exit Delay GLOSSARY LIMITED WARRANTY Alarm Time out Central Station Phone Number Central Station Account Number Important Test Your System Weekly 3 Central Station Communication Test Panel Disarmed This test should only be performed on weekends or at a time 1 Bell Battery Test Panel Disarmed designated by your alarm company Test your bell or siren by pressing MERU followed by CI 2 Secure all zones to light he Status Light an your keypad This will cause the bell or siren to sound for 2 seconds and also 3 Enter your User Code followed by or to Arm the initiate a test of the battery system 4 Violate your alarm by opening a window door etc 2 Zone Test Panel Disarmed The siren or bell should sound and the system will send the alarm Walk throughout the premises opening each protected door or signals to the Central Station window and activating each motion sensor Check the keypad to 6 Enter your User Code followed by to silence the alarm see that each respective zone number displays in the window Call Central Station to insure that the alarm signals were received properly KEYPAD CONTROLS AND INDICATORS Fire Alarm Light amp will flash and the Keypad Zone Lights 1 through 8 will light
14. ct regardless of the cause of such loss or damage Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages or differentiate in their treatment of limitations of liability for ordinary or gross negligence so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may also have other rights which vary from state to state equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient the receiving antenna relocate the computer with respect to the receiver move the computer away from the receiver plug the computer into a different outlet so that computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4
15. ection with Buyer s order of the goods furnished hereunder NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY Warning Despite frequent testing and due to but not limited to any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all cases provide adequate warning or protection A properly installed and maintained alarm may only reduce risk of burglary robbery fire or otherwise but it is not insurance or a guarantee that these events will not occur CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING Therefore the installer should in turn advise the consumer to take any and all precautions for his or her safety including but not limited to fleeing the premises and calling police or fire department in order to mitigate the possibilities of harm and or damage NAPCO is not an insurer of either the property or safety of the user s family or employees and limits its liability for any loss or damage including incidental or consequential damages to NAPCO s original selling price of the produ
16. here is movement in that area 2 will light Depending upon the actual layout your security professional has chosen to properly protect your premises each zone may function a little differently The zone protecting your front door may be programmed as an Exit Entry zone to allow you time to enter the premises and disarm the system without inadvertently sounding the alarm Alternatively a zone protecting a window could be designated as an instant zone so that if it is entered or opened while the system is on armed there will be an immediate alarm Your easy GEMINI Keypad puts super simple system control at your fingertips Most keypad commands involve entering your four digit User Code This includes Arming or activating and Disarming or deactivating the system Simply put ARMED means the system is ON DISARMED means the system is OFF If the system is OFF and you want to turn it ON just enter your Code To turn the system back OFF enter your code again It s easy just always remember in the event of an alarm entering your User Code will silence all Sirens Your keypad is your command and status center it keeps you informed visibly using its zone and status lights and audibly using its built in keypad sounder For more information please see Keypad Controls and Indicators on page 4 TABLE OF CONTENTS TABLE OF CONTENTS System Information KEYPAD CONTROLS amp INDICATORS ARMING AWAY SETTING THE ALARM WHEN LEAVING ARMING STA
17. ior agreements or representations whether oral or written are either merged herein or are expressly cancelled NAPCO THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this NAPCO Security Systems 333 Bayview Avenue Amityville NY 11701 16 neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise or grow out of Seller s rendering of technical advice or service in conn
18. refully Discuss each of these escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat rushes in Crawl through the smoke holding your breath Close the doors again on leaving to help prevent the fire from spreading Go to your specific outdoor meeting place so you can see that everyone is safe Call the Fire Department from a neighbor s telephone GR FIRE PROTECTION Floorplan Draw a plan of your premises below FUNCTION MENU By pressing venu followed by the the appropriate key do not press simultaneously these special functions and features can be enabled Easy Arm when system is disarmed The Easy Arm feature allows the system to be armed by pressing ven followed by Lo This will allow the easy arming of the system by someone who is not a regular system user Easy Exit when system is armed This function if programmed allows an occupant to leave the premises without disarming the system Pressing veny followed by while the system is armed will start a 3 minute period during which you can leave through the Exit Entry door Bell Battery Test Pressing menu followed by CJ will cause the
19. system is armed or disarmed Discuss these Buttons with your installer The emergency signal will only be activated when the two respective buttons are pressed at the same time Fire Alarm Simultaneously press 7F j to sound a fire alarm and to alert the central station of a fire emergency if so programmed Auxiliary Alarm Simultaneously press 8A J j to alert the central station of an auxiliary emergency if so programmed The nature of this emergency alarm is to be determined by the installer Police Emergency Simultaneously press 9P j j to sound a police emergency alarm and to alert the central station of a Police emergency if so programmed Ambush Alarm In the event that you are forced by an intruder to disarm your system the ambush alarm can be activated Disarming the system with the Ambush Code will cause the system to disarm and simultaneously send a silent ambush alarm signal to Central Station If your system has the Ambush feature enabled the code assigned as the User 8 code will function as your Ambush Code TURNING OFF THE ALARM DISARMING WHEN RETURNING Disarming the System 1 Enter your premises through the Entry Exit door The keypad will sound a steady tone to remind you to disarm the system before your Entry Delay time expires 2 Enter your User Code and press The red Armed light will go out indicating that the system has been disarmed Note If you make a mistake entering
20. t the keypad to alert that Entry delay has started System Trouble A problem has been detected in the system which may prevent it from working properly TROUBLE will be lit to indicate a system trouble User Code A four digit code which is used to arm and disarm the system from the keypad User 1 Code A four digit code which can be used to program re program and erase user codes as well as arm and disarm the system from the keypad Zone An area which is protected by a security device Your front door may be designated as Zone 1 while the living room motion detector may be Zone 2 Refer to the Zone Label on your keypad for the Zone Identification of your system 15 NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS INC NAPCO warrants its products to be free from manufacturing defects in materials and workmanship for thirty six months following the date of manufacture NAPCO will within said period at its option repair or replace any product failing to operate correctly without charge to the original purchaser or user This warranty shall not apply to any equipment or any part thereof which has been repaired by others improperly installed improperly used abused altered damaged subjected to acts of God or on which any serial numbers have been altered defaced or removed Seller will not be responsible for any dismantling or reinstallation charges THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EX
21. ur Ambush Code Arming Turning the system on by entering your user code at the keypad followed by E N N E A Auto Interior Bypass A feature which allows the system to recognize when you have not left the premises and automatically bypass any interior zones deactivating devices such as motion sensors allowing free movement throughout the premises Battery A backup source of power to provide protection for a limited time in the event of a power failure Bypass the manual or automatic removal of one or more protection zones from the system Press Bypass and then the zone number to bypass a zone Central Station Monitors alarm emergency and trouble reports from the alarm system and notifies proper authorities Chime a keypad beep which indicates that a door has been opened while the system is disarmed Easy Exit Allows an occupant to leave the premises without disarming the system Pressing venu and then while the system is armed will permit exit by removing the protection on the Exit Entry door for 3 minutes Exit Entry Delay The amount of time you are allowed to enter and leave the premises when the system is armed Exit Entry Zone A zone which will allow you to enter and leave the premises when the system is armed Instant Protection Arming without Entry Delay while remaining on the premises Press and hold stay while armed Keypad Sounder A local warning device a
22. ype as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire 4 Beeps 1 8 Wireless Transmitter A problem has been detected with a wireless transmitter Call installing company for Supervisory Failure service 5 Beeps 1 4 Wireless Smoke The battery in a wireless smoke detector is low and should be replaced This wireless Detector Low Battery smoke detector should be marked with a number corresponding to the number of the lit zone light The replacement battery is the Duracell MN1604 9 Volt Alkaline 2 required Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire 6 Beeps 1 4 Wireless Smoke A problem has been detected with a wireless smoke detector Call installing company Detector Supervisory for service Failure Zone Trouble Call installing company for service 13 PROGRAMMING OPTIONAL Your Installer has assigned a User 1 Code which can be used to not only Arm and Disarm the system but also to enter the User Program Mode where you can program other user codes The following explains how you will use this code to program or erase additional user codes Entering the User Program Mode With the panel disarmed press Menu followed by and enter the User 1 code folowed by i The Armed Status and
Download Pdf Manuals
Related Search
Related Contents
Linear Motor Specifications and Instruction Manual Faça o do manual Remote Transformation SSD210L Installation Manual [PDF 4.5 MB] DISEÑO DE PROCESADORES DEDICADOS Práctica 2 CIDETEC Samsung P42H Korisničko uputstvo Kodak I1300 User's Manual Product Manual User manual - Russell Hobbs Betriebsanleitung Pega 40 Version 3 Copyright © All rights reserved.