1. PLASMATRONICS SPSD ENET BROWSER BASED INTERFACE USER GUIDE Introduction Connection Web Pages Network configuration default Network configuration management Activity Light Board Jumpers Figures SPANAMR YEN 1 Introduction The SPSD ENET is a factory fitted option for the Plasmatronics SPS solar charge controller The SPSD ENET option provides e standard Ethernet connection e web based configuration using any standard web browser 2 Connection Use a standard Ethernet cable to connect the SPS solar charge controller to your network To open the SPS solar charge controller web page go to http SPSD ENET or http 192 168 1 100 or use the name or URL provided by your network administrator If you cannot connect to the SPS solar charge controller web page contact your network administrator or follow the instructions given below to configure your computer and network ENET_User_Guide v2 1 Page 1 of 6 PLASMATRONICS SPSD ENET 3 Web pages The SPS solar charge controller has four web pages Status default figure 1 Settings figure 2 History figure 3 Network figure 4 To navigate between web pages click on the Status Settings History Network links on each page or use the page name with the web address http SPSD ENET status The web pages are displayed English or in the language of your web browser if the SPSD ENET board supports that language To force the pages to display in English use the al
2. PSD ENET option supports NetBios Name Server requests If the network is configured for ENET_User_Guide v2 1 Page 2 of 6 PLASMATRONICS SPSD ENET NBNS requests the SPS solar charge controller will reply to web requests to the configured Hostname This is the common configuration for PCs and internal networks If your Network or PC has NetBios turned off you can contact the SPS solar charge controller by using its IP address You can also assign a different host name to the IP address of the SPS solar charge controller by using a DNS server or by making an entry in the Hosts file on your PC The default IP address used by the SPS solar charge controller is not visible on the internet It is not a routable IP address In general SPS solar charge controllers should not be directly connected to the internet You should use a direct connection or a private network or a virtual private network to monitor and configure your SPS solar charge controller 4 Network configuration management You must login to change values on the Network page You will be presented with a Login dialog when you try to change values on the Settings or Network pages Values on the network pages will change when you push the Send button If you change the IP Address this will immediately disconnect you from the ENET board You can reconnect using the new IP address After values have been sent to the Enet board previous values may be restored by power cycling the Enet bo
3. ard or by using the Factory Reset jumper or by pushing the Reload Default or BOOT buttons Press the Save button after the Send button to permanently set the new values After the new values have been Saved power cycling or the Reload and BOOT buttons restore the Saved values Factory Reset jumper and the Default button restore the factory default values If you use the Site Name the NetBios name to connect to the Enet board the Site Name with its Ethernet address will be cached on your PC for some time If you change the Site Name you can use the new name immediately but the old name will also point to the same IP Address If you plan to change the Site Name and the IP Address change the Site Name and the IP Address at the same time then press Send so that the new Site Name points to the new IP Address immediately Re connect using the new Site Name then press Save you will need to login again to make the new values the saved values IP address Net Mask and Gateway values must be entered as dotted decimal values Changed password must be entered twice If the password change is accepted you will be presented with a login dialog when you press the Save button 6 Activity Light Normal configuration is Activity and Connection Status If the Connection Status is Off the Activity light goes to a slow blink If the Reset jumper is connected the Activity light is On 7 Board Jumpers Jumper A is the unlock jumper Remov
4. e Jumper A to lock the network settings SPS controller settings or both The lock options may be set on the network page while the unlock jumper is connected Status of Jumper A may be seen on the Network page Jumper B is the Factory Reset jumper While Jumper B is in place an ENET board Factory Reset occurs once per second There is no effect on SPS controller settings Hold the Reset jumper until the Activity light comes on up to 1 second may be required Status may be seen on the Network page ENET User Guide v2 1 Page 3 of 6 PLASMATRONICS SPSD ENET 8 Figures 1 Status SPSD Solar Controller 7 Status Settings History Network Battery Voltage 28 0 V Controller Type Negative Ground 24V 150 2994 Charge Current 6444 Load Current 31 64 Day Charge Ah 216 Ah Day Load Ah 58 Ah Regulator State 0 Day Maximum V Bosy Day Minimum V 44v Load disconnect Normal Low battery alarm Normal High battery alarm Normal Logie fail Ace 0000000000000 Load fail Norma Solar bank switch fail Normal Generator control Normal Alarm Inputs BEBE tour Stas 1111111 2 Settings SPSD Solar Controller sare Status Settings History Network Boost Maximum Voltage V 23 0 Boost Taper Voltage V 28 0 Number of Banks Used ja Float Maximum Voltage V 28 0 Float Minimium Voltage V ero Boost Cut in Voltage V
5. o48 Absolute Maximum Voltage V 50 4 Temperature Compensation mV cell State Change Delay minutes Display Contrast fo fio Display Temperature Setting Deg C fo fea ea Load Disconnect Voltage V 22 4 Load Reconnect Voltage V 25 6 Delay Before Disconnect seconds eno Low Battery Alarm V 23 0 Send ENET User Guide v2 1 Page 4 of 6 PLASMATRONICS SPSD ENET 3 History M SPSD Solar Controller Status Settings History Network Day Charge Ah Load Ah Minimum V Maximum V 1 180 72 23 2 29 6 2 72 90 234 288 3 70 87 230 28 6 4 306 93 248 30 6 5 296 67 244 302 6 276 85 238 30 6 T 220 69 240 30 0 8 80 55 260 280 9 90 50 260 280 10 276 40 258 30 2 11 210 57 25 0 30 8 12 306 70 248 30 6 13 266 128 250 294 14 256 79 244 30 6 15 220 77 244 30 0 16 266 68 240 30 0 17 180 72 238 29 6 18 110 92 23 4 288 19 130 97 248 288 20 190 115 244 296 21 296 67 244 30 2 22 180 85 238 30 6 23 50 49 260 280 24 80 30 260 280 25 90 20 260 280 26 276 40 258 30 2 27 210 37 250 30 8 28 306 100 248 30 6 29 296 67 244 30 2 30 276 79 244 30 6 31 220 69 240 30 0 32 266 68 240 30 0 Last Reset 923564 ENET User Guide v2 1 Page 5 of 6 PLASMATRONICS SPSD ENET 4 Network SPSD Solar Charge Controller Network Configuration Windows Internet Explorer N 6 e le http 192 168 1 100 network v lix sos lel Fie Edit View Google Gr Favorites To
6. ols Help Go O w d spsp Solar Charge Controller Network AutoFill ai Send tov Q Settings m B dmh i Page I Tools d SPSD Solar Controller Status Settings History Network IP addr 192 168 1 100 NetMask 2552552550 Gateway 192 168 1 1 MAC 00 60 35 09 B4 4E DHCP client enabled v Site Name SPSD ENET User Name SPSD Passwort Version Dec 08 2008 16 27 19 Password Jumper A Closed Jumper B Open Open A i Locks Network Closed B Factory Reset http 192 168 1 100 network L internet amp 1005 1 54 PM Solar Charge C ENET User Guide v2 1 Page 6 of 6
7. ternate page names en Status en Settings en History The first value displayed on the Status Settings and History web pages will be a cached value The page will automatically refresh with a current value after a few seconds The web pages then go to a slow refresh cycle Press refresh on your web browser to force a faster update The SPS solar charge controller user guide contains more information on SPS status and settings values The default username to change SPS settings is SPSD The default Password is ENET Both words must be uppercase The user name and password may be changed on the network page see below 4 Network configuration default The SPS solar charge controller with SPSD ENET option has a standard 10 0Mbps Ethernet connection Use a cross over cable to connect directly to a PC or a standard cable to connect to a hub or switch Use a 10 0 Mbps switch or hub if available Do not use a 100 0Mbps or 1Gbps switch or hub unless it is auto sensing Configure network cards to 10 0Mbps for direct connection using a cross over cable The SPSD ENET option has default values IP address 192 168 1 100 netmask 255 255 255 0 NetBios Name SPSD ENET user name SPSD password ENET On a network without DHCP the default values will be used If there is a DHCP server the DHCP server will provide the IP address and may provide the following DHCP options 1 Subnet Mask 255 255 255 0 12 Hostname SPSD ENET The S