Micro automation platform
Contents
1. The topology of the AS i bus is unrestricted a lly marti lies IE Line Q o Tree Ring 43610 EN FM 2 Schneider Electric Micro automation platform AS i bus AS i is a master slave bus the slaves are managed by a single master The master interrogates each slave on the bus in succession and waits for a reply The maximum time for the interrogation cycle is 5 ms for 31 discrete slaves Dialogue is always initiated by the master The AS i master on a Premium PLC can be a module from 1 to 8 modules or a gateway on the Fipio fieldbus from 1 to 16 gateways On the Micro PLC the number of modules is limited to 1 ii el Q Each PLC with an AS i module enables user transparent Each gateway converts the AS i bus into a Fipio bus communication device address on a higher level Please refer to our specialist catalogue AS i accepts up to 31 slaves each with 4 input bits and 4 output bits for cyclical exchange of data with the master and 4 parameter setting bits for extended functions configuration diagnostics etc Each slave has its own address and a profile definition of the exchange of variables The communicating sensors or actuators incorporating a specific AS i component are connected directly to the AS i bus using passive splitter blocks or T connectors Conventional discrete sensors or actuators are connected to the bus using active splitte
2. 43312 EN FM 8 Micro automation platform Ethernet network and TCP IP Modem serial link Graphic object editor function available on the TSX ETZ 510 module The graphic object editor function enables you to create graphic designs including animated graphic objects linked to PLC variables These customized designs can be used in user Web pages created with FactoryCast software These designs are created using simple cut paste operations and the objects are set according to the needs of the user color PLC variables label Once the designs have been created they can be saved in a transparent way in the Ethernet TSX ETZ 510 module Display of predefined Web pages available on the TSX ETZ 510 module The TSX ETZ 510 module also has an 8 M bytes 1 Flash EPROM type memory which is accessible as a hard disk and permits the reception hosting of Web pages defined by the user These Web pages can be created using any standard tool that lets you create and edit in HTML format Eight pages can be enhanced by inserting animated graphic objects provided by the graphic object editor Once created these Web pages allow you to m Display all PLC variables in real time m Insert hyperlinks to external servers documentation suppliers This function is particularly useful for creating graphics and images intended for m Display monitoring diagnostics m Development of real time production reports
3. Resistance to LF interference Type of power supply Primary Voltage Nominal Limit including ripple Frequency Nominal limit Current Nominal input Inrush 2 Micro breaks Accepted duration Secondary Power Total useful typical Output currents 5 V output 24 V output sensors Protection integrated on the outputs against Overloads Short circuits Isolation Dielectric resistance Primary secondary Functions references pages 43050 6 and 43050 7 Schneider Electric Output 24 VR for relay outputs 0 60 5 55 conforming to IEC 61131 2 0 70 with TSX FAN ventilation modules 25 70 conforming to IEC 61131 2 10 95 without condensation 5 95 conforming to IEC 61131 2 without condensation 0 2000 Conforming to IEC 68 2 6 Fc test Conforming to IEC 68 2 27 Ea test Conforming to IEC 1000 4 2 level 3 1 Conforming to IEC 1000 4 3 level 3 7 Conforming to IEC 1000 4 4 level 3 7 Conforming to IEC 1000 4 5 Conforming to IEC 1000 4 12 Conforming to IEC 61131 2 power supply power supply 100 240 2 V 90 264 19 2 30V possible up to 34 V for 1 hr per 24 hrs 50 60 47 68 lt 0 7 100 V lt 0 3 240 V 2 EA E 16 lt 1 2 period repetition gt 1 s lt 10 ms repetition gt 1 s 24 32 peak 18 peak 2 2 8 3 2 peak 3 2 peak 8 0 4 0
4. 43560 EN FM 3 Micro automation platform Bus and network modules Ethernet TCP IP or RS 232 Modbus Plus Modem PPP 10 100baseT RJ45 Modbus Plus standard CSMA CD Rotating token 10 100 Mbps 1 Mbps Double twisted shielded pair Twisted pair Fiber optic 64 32 per segment over 64 segments 100 m max between hub 450 m per segment and terminal device 1800 m with 3 r peaters maximum 1 maximum TCP IP ou PPP Modbus message handling Messagerie Uni TE or service Modbus Write read variables Server service Global database BOOTP DHCP SNMP Agent service Communication tranparency on Ethernet or Modem link Integrated Web server with or without Web user page 8 Mb TSX 37 10 21 22 PLC bases TSX 37 21 22 PLC bases Independent module Type III PCMCIA card 43312 11 43599 3 0464Q EN FM 2 Fipway Fipio Agent Fip standard Bus managed by bus arbitrator 1 Mbps Twisted pair Fiber optic 32 per segments over 64 over 128 segments segments 1000 m per From1000 to electrical 15 000 segment depending 500 m max onthe m dium use 1 maximum Uni TE Application to application COM shared Periodic table data Telegram exchange Transparent exchange of remote I O 43593 3 Schneider Electric Multicomponent industrial buses Character mode Uni Telway Modbus RS 485 non isolated RS 485 isolated via TSX P ACC 01 compulsory for Modbu
5. Once installed the SMC converter is activated from PL7 File Convert command Translated program modules are converted into an importable source format in a new PL7 application or in the current application A consistency check is performed with the current application configuration It is also possible to modify the destination application while the converter is being used suc Conver tisseur SMC APPLI_LO Configur stUtilis s 10240 mots configur s SMC 23 de 109 1022 PL 23 de 109 4 15000 PL Junior lt Sans nom gt Fichier Edition Services E sala aleje Configuration tsx 5710 v1 5 2 PL7 source files LD file SCY file SMC applications Timer s rie 7 Bit tape 1 USYS local MOF Reference page 43103 3 431 03 EN FM 2 Schneider Electric Functions Micro automation platform reference PL7 SMC application converter software Database conversion The converter is extremely easy to use All or part of the symbolised database can be retrieved lts reassignment services operate on individual data or blocks of data addresses I O reassignment des Edition Services wue Outils AP Debug Options Fen tre a al o el The converter in particular enables discrete I O variables aiia from an SMC PLC to be directly reassigned by module to Micro Premium PLC modules It is also possible to merge objects f
6. One high density 15 way SUB D connector per channel for connecting Counter sensors or incremental encoder Encoder power supply Encoder power supply feedback for checking that this is correctly supplied poo N 20 way HE 10 connector for connecting the following to each channel Auxiliary inputs preselection counter enable and read Power supplies for auxiliary inputs sensors and incremental encoder s o O 3 Locking system for fixing the module in its slot Schneider Electric Applications N m m Counter E E E Mi _ ES sensor O O OOO ry 0D Operating direction Counter Preset Time N Output sensor 0D Operating direction Tunnel total Max Min Alarm Time 4 Edge m p detection sensor Pc Pulse counter Pc resence of item L max L min A _ Item outside range Time Speed sensor Pc S max S min Alarm Time Specifications References page 43054 4 page 43054 5 Schneider Electric Micro automation platform Integrated counter channels and counter modules Example of upcounting or downcounting This example shows the grouping of objects supplied by a conveyor belt for packaging This simple counting application uses a sensor proximity sensor photoelectric sensor linked to a preset counter When the preset value is reached the packaging command is activated and the control system initiates
7. 24 V 0 5 A Inputs 24 V Connection via 20 way HE 10 connector 8 12 or 16 channels with or without LED with common or 2 terminals per channel Inputs 16 channels 5 V TTL 24 V 48 48 V 115 V or 230 V 2 terminal per channel Outputs 8 or 16 chan with 1 N O 1 or C O or solid state relays 5 48 V 24 v 24 240V 1 or 2 terminals per channel Sensor voltage monitoring Type 2 Positive 2 wire 2 wire 3 wire PNP Preactuator voltage monitoring Configurable fallback of outputs Yes Protected Positive TSX DSZ 04122 TSX DSZ 08T2 TSX DSZ 08T2K TSX DEZ 12D2K 8 1 0 Inputs 24 V Outputs 24 V 0 5 A Yes see page 15000 2 Yes see page 15020 2 Sensor voltage monitoring MA Positive 2 wire 3 wire PNP Preactuator voltage monitoring Configurable falloack of outputs Yes Protected Positive TSX DMZ 16DTK 43051 9 Schneider Electric CINCCANMIQ UC 0467Q EN FM 3 Connection principles TA padan lt A Ud ZTA ay la oe y an JITIIA TIRO 74 WE 3 Specifications pages 43051 5 to 43051 8 43051 EN FM 2 References pages 43051 9 and 43051 10 Micro automation platform Discrete I O modules The screw connection terminal blocks are fitted with a removable cover ensuring m The screws are held in place m Personnel safety Each terminal on
8. Each section 1 has a name a comment and is programmed in one of the four languages available in PL7 A section programmed in Grafcet language can contain a main chart 2 and macro steps 3 Version gt V4 0 of PL7 allows comments to be added to each macro step To protect intellectual property or avoid any unwarranted modification each section can be write protected or read write protected Management of access rights Use of the various PL7 software functions can be limited and controlled by managing the access rights There are 5 user profiles differentiated by passwords which characterize the functions available to users on the programming terminal The profiles range from read only access to an application lowest profile to full programming profile with the most rights 43100 EN FM 3 Installation continuea P PRO APP5725F Configuration wer Edition ices Vue Outils AP Debug Options Fen tre 2 RANONW amy Anar na vao D300 anan no anano Mmno Configuration TSX CTY 4A RACK O POSITION 5 Capture sur Capt 5 Front montant Capt f Characteristics pages 43100 13 to 43100 15 43100 EN FM 4 References page 43100 17 Micro Automation Platform PL7 Micro Junior Pro programming software Hardware configuration The configuration editor intuitively and graphically enables the declaration and configuration of the various components of the Micro Premium PLC appl
9. Presentation description selection Micro Automation Platform TSX 37 21 22 PLCs Modular TSX 37 21 22 PLCs differ in their supply voltage and or the possibility of fast counting and analogue functions integrated on the base Each PLC comprises a 3 slot rack which integrates a power supply 24 V or ny 100 240 V a processor including a 20 Kword RAM memory program data and constants 1 Flash EPROM backup memory 2 slots for a PCMCIA card 1 communication card and 1 memory extension card of 64 Kwords maximum and a real time clock A TSX RKZ 02 mini extension rack enables the number of slots to be increased by 2 4 positions Each available slot can accept m 1 standard format discrete I O module m 2 half format discrete I O safety analog I O or counter modules Also TSX 37 21 22 PLCs can connect to the Ethernet network TCP IP or to a Modem via the TSX ETZ 410 510 external stand alone module 9 3 4 52 1 TSX 37 21 22 PLCs and the TSX RKZ 02 mini extension rack comprise 3 slot base rack positions 1 to 6 Slot reserved for a standard format module Centralized display block Terminal port TER Uni Telway or Modbus Master Slave protocol Man machine interface port labeled AUX Slot for a memory extension card Cover for accessing the power supply terminals Slot for a communication module On TSX 37 22 connectors for integrated analogue and counter functions 10 Mini extension rack with 2 available slo
10. Stop Bit fi gt Max time between 2 frames s P Max connection time s po Hayes ATEF ATS0 2 Rack Viewer function Micro PLC diagnostics The predefined Rack Viewer function display of PLC rack is used to diagnose the Micro PLC connected to the network via the Ethernet module This is a predefined secure function accessed using a password which allows real time display from a standard browser ce a u A m The status of the LEDs on the front panel of the PLC me Ethernet Statistics R f rence pr sente TSXAEZ 802 Type de produit In rack F ee NE TAE m The version type of the PLC cto nn sen m The hardware configuration of the PLC with the status of the system words and bits m The detailed diagnostics of each I O module or application share this configuration me Ethernet Statistics Unitelway Statistics Rack Viewer Data Editor Graphic Editor FDR Statistics FactoryCast Schneider Automation Inc 2000 2001 e Ei manine Communication diagnostics function Operational Statistics Receive Interrupts 16955827 Transmitintemupts 1405628 Functioning Errors Transmit TimeoutErrors E CollisionEnors m The Ethernet network statistics Missed PacketEmors 0 MemoryEnors m The Uni Telway bus statistics Restart po m The RS 232 Modem serial link diagnostics Receive Statistics Framing Errors fo ye rflow Errors CRC Er
11. l YolW ae o and 2 IRead read input setpoints event management Monit TSX DSZ E gt discrete gt Ouiputo encoder line break 1 output Output 1 module 1 With TSX CTZ 1A 2A 2AA counter module IA IB IZ IPres lEna Read CO per chan 0 OA BD chan 11 2 CCO Se chan 12 PA e a 2 per chan KE 163 Physical input available 1 Input IB can be defined by software configuration in input IPres 2 Software input possible Counting functions are configured and installed using PL7 Micro or PL7 Junior software see page 43100 9 TSX CTZ 1A TSX CTZ2A TSXCTZ2AA TSX 37 22 TSX DEZ DMZ FS E 16 E NO i 24V 100 120 V 40 40 500 10 0 02 100 with 24 V sensors with mechanical output limit switches etc Taking account of an input and positioning of a discrete module output 1 5 2 aking account of an event triggered input and positioning of a discrete module output 4 A IA be oon See page 43311 2 AJA lt 3 lt lt 3 lt lt Counter inputs Integrated channels Auxiliary inputs TSX CTZ 1A 2A 2AA MN TSX CTZ ee Integrated chan 24 24 24 10 19 30 19 30 3 19 30 gt 11 gt 37 U 2 4 V 4 gt 2 5 lt 5 lt 1 U 12V lt 2 U 5V lt 065 lt 2 x2z______ lt 1 4 Positive 1 4 2 4 5 Resistive Currentsink Currentsink Resistive Type Typei Type2 2 wire B wire
12. 1 Cannot be used with Nano extensions Length 200 m References page 43056 3 43056 EN FM 2 Schneider Electric Description Micro automation platform selection TSX STZ extension module for Nano PLCs reference The front panel of the TSX STZ 10 I O extension module for Nano PLCs comprises 1 Locking system for fixing the module in its slot 2 Three indicator lamps to display module operating status RUN correct operation of module ERR error in module 1 COM display of link traffic 3 Opening for cable routing 3 d Location position 4 of Micro PLC base Type ower Supply Upe of aseme input ape of discrete output 1 analogue channel References modules as extension 100 240 V 24V 24 V i 15V Negative Positive 24 V Input Output TSX 07 30 1028 10 discrete I O bases 6 inputs 4 outputs 1 E e 07301008 es ay 16 discrete I O bases O O ee ie TSX 07 31 1628 9 inputs 7 outputs IO II E OI TSX 07 31 1648 1 IE C E S TSX 07 31 1622 IS 24 discrete I O bases IS O ee 14 inputs 10 outputs Po re 1 IO O _ TSX 07 31 2422 IS Extensions 9 inputs IO O CO TSX 07 EX 1628 7 outputs 2 a IA gt TSXO7 EX 1612 Extensions 14 inputs IO E CO TSX 07 EX 2428 eo TSX07 EX 244 2 TSX AMIN 4000 TSX AMN 4001 Function performed 10
13. 100 240 V a processor including a 14 Kword RAM memory program data and constants a Flash EPROM backup memory a real time clock a discrete I O module 28 or 64 I O and an available slot A TSX RKZ 02 mini extension rack enables the number of slots to be increased by 2 4 positions Each available slot can accept m 1 standard format discrete I O module of any type m 2 half format discrete I O safety analog I O or counter modules Also TSX 37 10 PLCs can connect to the Ethernet network TCP IP or to a Modem via the TSX ETZ 410 510 external stand alone module TSX 37 10 base PLC selection TSX 37 10 PLCs and the TSX RKZ 02 mini extension rack comprise 2 slot base rack Centralized display block Terminal port TER Uni Telway or Modbus Master Slave protocol Cover for accessing the power supply terminals 28 or 64 discrete I O module placed in the first slot positions 1 and 2 Cover for accessing optional battery Mini extension rack with 2 available slots positions 5 to 8 LED showing presence of 24 V Power supply terminals protected by removable cover to connect an auxiliary 24 V power supply if PLCs are supplied with 100 240 V 10 Earth terminal 11 Connectors to the base PLC 12 Reset button OO JO OLA ON Power supply I O module integrated in 1st slot Connection Reference Connector Term bik 24 V 110 120 V Soli
14. 3 0 615 ABS 7SA2 ABS 75C2e ABE 7P16T230 3 0 655 ABE 7ACC20 Spring ABE 7P16T230E 3 0 655 Yes Volt free Screw ABE 7P16T214 0 675 i No Common Screw ABE 7P16T212 0 615 on both poles 4 ABE 7P16T2ee Yes Common Screw ABE 7P16T215 0 670 on both poles 4 8 12 ABR 7533 No No Volt free Screw ABE 7P08T330 0 450 ABS 75A30 ABS 75C300 ABE 7ACC21 Spring ABE 7P08T330E 0 450 16 12 ABR 7533 No No Volt free Screw ABE 7P16T330 0 900 ABS 75A30 ABS 75C300 ABE 7ACC21 Spring ABE 7P16T330E 0 900 Common Screw ABE 7P16T332 0 900 on both A poles 5 ABR 7533 No Yes Volt free Screw ABE 7P16T334 0 900 ABS 7SA3M ABS 7SC3E ABE 7ACC21 Yes Yes Common Screw ABE 7P16T318 1 000 on both poles 5 Spring ABE 7P16T318E 1 000 1 Not equipped with relays 2 2 connection methods are available enabling inputs and outputs to be connected to the same sub base at the same time 3 With relay ABR 7S21 for sub base ABE 7P16T210 with relay ABR 7S23 for sub base ABE 7P16T2300 4 Per group of 8 channels 5 Per group of 4 channels Presentation compatibility Dimensions schemes page 14029 2 page 14040 3 14025 EN fm 6 Schneider Electric 816475 816476 816474 References SEMENS GERMANY V23092 A1024 A302 2V Eras ABS 7SC1B ABR 7S2e ABR 7S3e Presentation compatibility Connection interfaces Telefast 2 pre wired system Plug in relays Relay Func Input circuit Output circuit Unit Weight width tions Current Nom
15. Debug MAST Bkpt Actif Pas 4 pas en cours EOE XI Animation of program elements Parts of the program are animated directly when the Micro Premium PLC is in RUN rung Structured Text statement or sequence of instructions in Instruction List language by activating the PL7 animation function Animation is used to display the status of program variables whatever the language used The animation can be frozen Several windows can be displayed and animated simultaneously Animation tables Tables containing the application variables to be monitored or modified can be created by entering them or automatically initialized from the selected program part Variables can then be modified forced to 0 or to 1 for bit objects These tables can be stored in the application and therefore retrieved at a later date Debugging the DFBs m Animation table all public parameters and variables are displayed and animated in real time It is possible to modify and force the desired objects m As for the rest of the program it is possible to use the following functions breakpoint step by step and program diagnostics Grafcet debugging In online mode the browser gives a hierarchical view of the chart with CHART module and macro step nesting Animation is characterized by the presence or absence of indicator colors The Grafcet debug bar m Displays the state of the chart m Modifies the state of the chart m Gives information on the state of the master t
16. RemplirRemplissage TOP W E files PL7 source LD file LIT file GR7 file scCY file Oe o Characteristics References pages 43100 13 to 43100 15 page 43100 17 43100 EN FM 12 Micro Automation Platform PL7 Micro Junior Pro programming software Variable cross references For every variable this function can be used to NW Search for program modules where this variable is used m Obtain the list of statements rungs or expressions m Display and check activation conditions A log is used to keep track of this navigation Options relating to the variable can be associated with the search extract bit table object function block elements network object etc This function can be initialized from the program or runtime screens Application converters PL7 Micro Junior Pro software includes application converters which make it possible to reuse in full or in part applications already written in m PL7 2 applications for TSX 17 TSX 27 or TSX 47 10 20 25 PLCs m PL7 3 7 applications for TSX PMX 47 TSX PMX 107 PLCs m ORPHEE 7 applications for April Series 1000 PLCs PL Junior lt Sans nom gt ES gt MES Application AP Debug Options Fen tre 2 Nouveau als Ouvrir Fermer Applications Enregistrer Ctrl S Enregistrer sous PL7 2 P L7 3 Importer une application Exporter une application Remplacer Convertir A
17. Weight 0 405 0 720 1 210 0 090 0 170 0 250 0 085 0 150 0 280 0 410 0 670 Weight kg 0 350 Weight 0 055 0 115 Schneider Electric Micro automation platform Discrete I O modules Connections TSX DEZ 12D2 Negative logic TSX DEZ 12D2 Positive logic TSX DEZ 12D2K Inputs Sink fotdtetatetefe Oe o o o o o eoo Sensors Inputs an gt Y N 1 Sink eel le ls al e oe ooo 0 O O o o o 8 o o Sensors Inputs Sensors 224 V Ala bel fe e ej is la le ll El z 24 V TSX DSZ 32R5 TSX DSZ 32T2 TSX DEZ 32D2 D 2 O 2 6 2 91 9 O 9 9 2 8 9 0 9 3 D O OOO OOOO OP Pele Pleleleje 3 G Slow a as 0 L S iile bel N e E e Eel A e N e E e Eel 3355 w O To Sle fit fist el piel el IS E le e fm 112 119 4 gt Ak oy Er NG Siecle an Oloj 5 SO gt Preactuators Inputs Aaa N el E E E e is ist kel bel e S ej S st el el e S e e N e EH E e loeloe ololoelelojoe HEHHEHEHHHEAEHHEHAHEA 1 Sensors Ave FU1 1 pages 43051 9 and 43051 10 References pages 43051 5 to 43051 8 Specifications 43051 EN FM 11 Oo E O LLI _ o oO Cc lt O ep TSX DSZ 08T2 Micro automation platform Discrete l O modules TSX DSZ 08T2K Conne
18. a IP 20 cable for connection of TBX dust ae and damp proof module 24 V supply TSX FP ACC 3 Dust and damp proof Trunk cable tap link TSX FP ACC 4 0 660 bus cable connector Fipio bus connection cables 2 Description Use Length Reference Weight From To kg Cables for TSX FPP 10 TSX FP ACC 4 1m TSX FP CG 010 0 210 PCMCIA card card cable connector IARR AGR miniature 9 way SUB D connector connector F EPE i 3m TSX FP CG 030 0410 1 The TSX FPP 10 card is only supported by Micro TSX 37 21 22 Premium processors Product supplied with bilingual Quick Reference Guide English and French 2 For other Fipio bus accessories and connection cables see pages 43597 6 and 43597 7 TSX FP CG 010 030 43593 EN FM 3 Schneider Electric Presentation Characteristics page 43590 3 43590 EN FM 2 Micro automation platform Fipio and Fipway on fibre optic cables When a high level of withstand to electromagnetic interference is required two solutions are available for using fibre optic cables on Fipio bus and Fipway network m Using TSX FP ACC 8M fibre optic electrical repeaters m Using OZD FIP G3 fibre optic transceivers Depending on requirements it is preferable to use m The OZD FIP G3 fibre optic transceiver if all devices on the network must be protected from electromagnetic interference 1 fibre optic transceiver for 16 stations maximum m The TSX FP ACC 8 repeater fibre optic link on one sid
19. decimal or binary code e DT i object list editor used to display or modify a list of 16 variables store and retrieve an object list 63 lists maximum This function requires a PCMCIA card e Frc editor to find forced bits is used to find and display forced bits in the PLC e FTX terminal editor is used to show the terminal versio select the language English French German Italian Spanish adjust a beep sound and lighting e Adr connection editor used to access PLCs connected to the UNI TELWAY bus master or slave e Trf transfer editor requiring a PCMCIA RAM memory card Used for transfers from PLCs to the PCMCIA card and vice versa a program and one or more MWi data files up to 10 data files via the FTX 117 terminal Schneider Electric Functions continuea Micro automation platform references FTX 117 Adjust terminal dimensions Objects which can be accessed by the terminal Language element Type Symbol Action 1 Inputs Input bit lx i R W F Input word single double IWi IDi 2 R W Outputs Output bit QXx i R W F Output word single double QWi QDi 2 R W Internal variables Internal bit Mi R W F 3 system bit word single double Si SWi SDi R W 4 Internal word single double floating point MWi MDi 2 MFi 2 R W Constant word single double floating point KWi KDi 2 KFi 2 R Network common word NW i k 2 R W Grafcet objects Step state Xi R W
20. e a 5 9 OMC A Client PLC can access other devices on the architecture via its application program lt can read write objects on another PLC or numerical controller select programs on a numerical controller etc Uni TE requests are transmitted using Communication function library for Micro Premium PLCs m TXT text function blocks or OFB function blocks for TSX PMX model 40 and TSX 17 20 PLCs The Uni TE request is transmitted atthe end of the master task and the response is received by the Client PLC at the start of the master task The Uni TE utility is particularly suitable for supervision diagnostic and control functions Uni TE service Ethernet TCP IP Ethway 7 Fipway Fipio Uni Telway Request size 256 bytes or 1 Kb 128 bytes 128 bytes 240 octets 2 Note The Uni TE service can be used between stations connected on different Ethernet TCP IP Fipway Fipio or Uni Telway segments of the same multi network architecture please consult our specialist catalogue no 42614 The programming terminals or TC2000 industrial PCs are Uni TE clients A terminal connected to any network station or connected directly to the Fipway Ethernet TCP IP network can communicate with any other station on the network all the exchanges are transparent to the user as though the terminal were physically connected to the PLC with which it establishes communication Terminal transparency can be used between sta
21. etc m Simple processes such as metal smelting furnaces ceramic kilns small refrigeration units etc m Servo controls or mechanical controls where the sampling period is crucial such as torque control speed control etc The variety of analogue input ranges 10 V 4 20 mA Pt 100 thermocouple etc and counter input ranges incremental encoder pulse generator etc enables them to interface directly with most industrial sensors which take measurements during processes The control executed by the process control functions can interface directly with analogue or discrete outputs as required Control loops are created in a simple and user friendly manner using 3 functions contained in PL7 Micro Junior Pro software m The PID function m The PWM function m The SERVO function Controller Presentation functions Inputs 4 20 mA CD Measurement Thermocouple Setpoint Probe Specfications page 43531 3 43531 EN F M 2 The PID function sets a PID serial parallel algorithm and works out the control signal on the basis of m A measurement sampled by an input module m The setpoint value fixed either by the operator or by the program m The values of the various controller parameters KP Tl TD sampling period etc The analogue control signal from the controller can be processed m Either directly by a Micro or Premium PLC analogue output module connected to the actuator m Or via the P
22. 1 k instructions 100 Boolean 65 Boolean and 35 numerical PLC types Memory capacity PCMCIA card Data MWi Constants KWi File storage Program Ladder LD 100 Boolean 65 Boolean and 35 numerical 100 Boolean 65 Boolean and 35 numerical List IL Structured 100 Boolean Text ST 65 Boolean and 35 numerical System overhead Functions references pages 43050 6 and 43050 7 pages 43050 13 and 43050 EN FM 12 Pemo 2 3 4 3 ES E 2 3 4 3 1 RS 485 channel Uni Telway 1 RS 485 channel Uni Telway master slave Modbus master slave Modbus slave or master slave or character mode character mode 7 gt 11 11 14 20 32 64 128 file storage 64 k k rar A 16 where 1 has priority 0 13 0 19 with PCMCIA card 4 50 0 17 0 25 with PCMCIA card gt jo mo O O 00 NO 00 oO Ol 3 71 3 76 with PCMCIA card TSX 37 21 22 TSX 37 10 2 Kwords 64 Kwords 1S 128 3 128 0 NMIN CAOS E 184 I i 4 8 4 N 2E oN AN gt z O D INES A a 4 28 4 amp 8 8 3 28 1 O gil S O O 21 Es 23 9 Nm ae ES ae eee al D P QR Jao T N 0O wo o Jo V X N al na N 7 Hage 1 1st value for connection via terminal block 2nd value via HE 10 type connector 2 Maximum numb
23. 10 Mains supply frequenc Hz 47 63 47 63 360 440 Nominal input current A E 8 A El Maxi inrush current 2 at240V__ A_ 30 HB 75 Maximum It value 2 at 240 V A S 8 5 Power factor 10 6 Efficiency at full load gt 80 Useful power 3 WwW 24 2 0 53 6 ___ 10 240 Nominal output current at60 C A Output voltage 0 to 60 C PAE Protection against short circuits wW Fallback to O and automatic reseton Current limit automatic resetting disappearance of fault Protection against overvoltages Peak limiting U gt 32 Prim second dielectric withstand O 3500 V rms 50 60 Hz 1 min user safety SELV conforming to EN 60950 and 50 60 Hz 1 min IEC 1131 2 Electromagnetic interference Class A in accordance with EN 55022 and conforming to FCC 15 A Degree of protection IP 205 IP 205 terminal block IP 215 Cooling _ By natural convection Parallel connection No Yes with power optimization 2 maximum Series connection No SOL Yess 2 maximum 1 Nominal voltage for a repetition period of 1 Hz 2 25 on initial power up These values must be taken into account when starting in order to size the protective devices 3 For an ambient temperature of 60 C Useful power given in for a fan cooled enclosure or a temperature range of 0 to 40 References Dimensions page 43560 3 page 43560 3 43560 EN FM 2 E Modicon Schneider Electric i E VA PE References Micro automation platform dimensions Process power supply units and m
24. 20 250 V UL 0 5 A 10 ABE 7FU050 0 010 1A 10 ABE 7FU100 0 010 2A 10 ABE 7FU200 0 010 4A 10 ABE 7FU400 0 010 6 3 A 10 ABE 7FU630 0 010 Description For Colour Distance between Reference Weight common cable ends kg cm Flexible Coil White 12 ABF C08R12W 0 020 commoning 2 ABF C08R02W 0 010 links N Red 12 ABF C08R12R 0 020 Modularity 2 ABF C08R02R 0 010 8x1mm2 Blue 12 ABF C08R12B 0 020 2 ABF C08R02B 0 010 My Telemecanique Schneider Electric Dimensions Common side view 1 Additional shunt terminal block ABE 7BV20 ABE 7ACC02 splitter sub base Micro automation platform Telefast 2 pre wired system ABE 7H P R S sub bases i 20000006 99999999 0000000000000000000A a ABE 7ACC80 enclosure feedthrough 20 References pages 14025 2 to 14025 5 Schneider Electric and 14040 2 ABE 7 HO8R1e H08R21 H08S111 H12R10 H12R2e H12R50 H16043 H16R10 H16R20 H16R3e H16R50 P16F310 P16T300 P16T2ee R08S111 R08S210 R08S2B0 R16S11le R16S21e R16T2ee R16T300 S08S2B1 S16E200 S16S1B2 S16S2B0 CPA01 CPA02 CPA03 CPA11 CPA12 CPA21 CPA31 ABE 7ACC10 11 redundant I O sub base 57 ABE 7ACC84 cable gland block 50 59 00000000 00000000 100000000 00000000 00000000 170 0000000 Oo d e 58 67 58 67 58 67 58 67 58 67 58 67 58 67 74 83 74 83 64 73 58 67 58 67 58 67 58 67 6
25. 200 m Analog digital conversion 11 bits sign of output values 43053 EN FM 3 Functions continuea Length 200m 43053 EN FM 4 Nano analog extension 31 10 Nano analog extension 31 10 Nano analog extension 31 10 Nano analog extension 31 10 Micro Automation Platform Integrated analog channels and analog I O modules TSX AMZ 600 provides 6 common point channels high level multirange voltage 0 10 V 10 V current 0 20 mA 4 20 mA of which m 4 input channels m 2 output channels The 4 input channels guarantee the following functions m Scanning of input channels used by solid state multiplexing normal or fast and acquisition of values m Analog digital conversion 11 bits sign or 12 bits of input signals The processing performed by the PLC processor in addition to the above functions is m Monitoring of input overshoots m Filtering measurements m Converting input measurements to user format for display in directly readable units The 2 output channels guarantee the following functions m The acceptance of digital values corresponding to analog values obtained as output These values are calculated by the PLC task to which the channels are assigned MAST or FAST m Processing dialog faults with the PLC and setting the outputs to fallback state value O or maintained m Selection of the range for each output voltage or current module TSX ASZ 200 m Analog digital
26. 4 Schneider Electric 43307 EN FM 5 Presentation Micro automation platform TSX STZ extension module for Nano PLCs The TSX STZ 10 I O extension module is used to connect up to 4 Nano devices which may be PLC bases analogue I O extensions or a discrete I O extension These remotely installed Nano bases or extensions 200 metres maximum from the Micro PLC can be used as m 1 O Of the Micro PLC In this case the number of I O managed by the Micro PLC can be increased by 96 discrete I O or 12 analogue I O m Local slave PLCs 7 with data exchanges from application to application between Micro and each Nano base the maximum number of Nano bases is limited to 3 In this application an FTX 117 terminal or PL7 07 software is required for software installation on Nano slave PLCs It is possible to combine both types of configuration on one link The TSX STZ 10 half format module is inserted in position 4 which means that its use excludes integration of the TSX SAZ 10 AS i bus master module Remote discrete I O configuration Remote discrete or analogue I O configuration enables L m a reduction in wiring costs in installations spread over a wide area Micro oso m the I O status display to be positioned close to the operative part m the application to be developed as required by adding l O blocks It is not necessary to configure or program the Nano bases Analogue Nano extension 3 inputs To simplify use of t
27. 6 peak lt lt 0 n n lt lt 0 NJN 2500 50 60 Hz No isolation O V internal connected to the PLC ground 1 Minimum level in the test conditions defined by the standards 2 Values to be taken into account when starting up several devices at the same time or when sizing protection devices V rms pages 43050 13 and 43050 14 page 43050 15 43050 EN FM 11 Characteristics continued Dran spharantarii r I UU YT Chal al cter Is Type of PLC Micro Automation Platform TSX 37 05 08 10 21 22 PLCs TSX 37 05 TSX 37 08 TSX 37 10 TSX 37 21 TSX 37 22 Functions I O Max no without remote 60 92 1 120 184 1 124 184 1 160 248 1 Max no Nano remote I O A 200 264 1 236 328 1 Max no remote VO on AS i bus O 340 404 1 376 468 1 Max no of modules 28 32 2 3 4 5 channels Max no of 64 channel modules 3 Analog Max no of modules 2 max 16 I or 8 O 4 max 32 or 16 O AAA No of integrated channels Counting positionin 2 g Max no of modules No of integrated channels No of channels on discrete inputs Max no of modules Communication Integrated channels terminal port No of PCMCIA card Real time clock Memory Internal RAM which can be backed up PCMCIA memory card Max memory size Application structure Master task Fast task Event processing Execution time standard instructions Boolean instruction numerical instruction Execution time for
28. 600 s SEPETTE as per group of 4 output channels ABE 7R16M111 2 input common terminals 10 ABR 7S21 1 N O Volt free ABE 7R16T210 0 735 Common ABE 7R16T212 0 730 on both poles 5 ABR 7S23 1 C O Contact common 5 ABE 7R16T231 0 730 Volt free ABE 7R16T230 0 775 12 ABR 7S33 1 C O Volt free ABE 7R16T330 1 300 Common ABE 7R16T332 1 200 on both poles 6 ABR 7537 2 C O Volt free ABE 7R16T370 1 300 1 Not equipped with relays 2 Sub bases may be equipped with electromechanical relays please consult your Regional Sales Office 3 Both technologies electromechanical and solid state may be combined on the same sub base 4 2 connection methods are available enabling inputs and outputs to be connected to the same sub base at the same me 5 6 Per group of 8 channels Per group of 4 channels ti Presentation compatibility _ Dimensions schemes page 14029 2 page 14040 3 Schneider Electric 14025 EN fm 5 References Connection interfaces Telefast 2 pre wired system Plug in relay sub bases No of Relay For Isolator Fuse Polarity Type Reference Weight chan width relay per per distribution of nels type channel channel application connection mm kg 16 5 ABR 7511 No No Contact common ABE 7P16T111 0 550 ABS 75C1B per group of 4 channels Contact common ABE 7P16M111 2 0 550 per group of 4 output channels and 2 common input terminals 10 ABR 752e No No Volt free Screw ABE 7P16T210
29. Ethernet TCP IP or Fipway network can communicate in read write mode with a Modbus Plus station the Premium PLC therefore acts as a gateway 4 A Premium or Micro client connected to the Modbus Plus network can access a remote station via the Modbus Plus Modbus gateway References page 43599 5 W Modicon Schneider Electric BEE T Leanna aml anna Description Micro automation platform characteristics Modbus Plus network Premium Micro PLCs are connected to the Modbus Plus network using a TSX MBP 100 type III PCMCIA card This card is installed in the slot reserved for processors or coprocessors 1 A host slot on processors or coprocessors 2 A protective cover with fixing screw access to miniature 20 way connector 3 A removable cover 4 Two indicator lamps O ERR card or link fault o COM activity on the line Connectors to be ordered separately TSX MBP CE 0ee tap off cables Structure Type Industrial bus Physical interface RS 485 Method of access Token bus Transmission Mode Synchronous HDLC Data rate 1 Mbps Medium Twisted pair fibre optic Configuration Number of devices 64 maximum on 1800 m twisted pair 32 per segment Number of addresses 64 devices maximum per segment Length of bus 450 m maximum per segment 1800 m maximum with 3 repeaters Number of segments Cascaded 5 maximum using Modbus Plus BP85 bridges Services Global database 4096 byte common database cyclical exchan
30. I O Specifications modules S pec ifications of I O modules Type of input modules TSX AEZ 801 TSX AEZ 802 TSX AEZ 414 Number of channels 8 8 4 Input ranges E azo ma Thermocouples temperature probes high 0 10 V 4 20 mA level see range below Analogidigital conversion bits Meson 12 Acquisition period Normal cycle ms BR 520 Fast cycle ms 4xNo ofchannelsused Measurement filtering Digital of the first order with modifiable filtering coefficient Hardware filtering 1st order Cutoff freg 33Hz 0 Cut off freq 169 Hz thermocouples 1 Maximum error at 25 C see below 0 60 C see below Maximum temperature drift 10 C 0 08 voltage 0 1 current Input independence 250 MQ 10 MQ Isolation Betw chann and bus V rms 1000 500 Betw chann and V rms 1000 500 earth Betw channels Maximum excess voltage on inputs Consumption Common point 30 V differential inputs s0 p3 30 See page 43311 2 Input ranges for TSX AEZ 414 Voltage current 10V 0 10 V 0 5 V 1 5 V 0 20 mA 4 20 mA Maximum error at 25 C FS 0 03 0 03 0 04 0 06 0 18 0 22 0 60 C FS 0 30 0 33 0 40 0 47 0 59 Temperature probe Pt 1000 Ni 1000 at 25 C 0 60 C Maximum error 0 7 7 9104xM 2 10 2 1 7 37 5 104 x M 2 0 7 Thermocouple Maximum error 3 at25 C Ext c 0 60 C Ext c Type of output modules Number of channels Output ranges Digital analog conversion Response time Maximum re
31. Mbps 1 10baseT port with RJ45 shielded connector 1 100baseTX port with RJ45 shielded connectors 1 10baseFL port with BFOC connector 1 100baseFX port with SC connectors Twisted pair cables or fibre optic cable 1 x 5 way lt 18 32 safety low voltage 9 6 57 6 safety low voltage Power supply 80 typical 160 typical 100 max 190 max Twisted pair 100 max Fibre optic 62 5 125 um 3100 max 11 with fibre optic cable 50 125 um 14 with fibre optic cable 62 5 125 um Power supply data exchange collision and line status via communication port Sy Ey References page 48190 7 Schneider Electric 48190 EN FM 5 Characteristics continued Types of bridge Network interconnection Operating voltage Ethernet ports Mounting Dimensions L x H x D Types of cable Type Length Preformed connectors Approvals and conformity Types of cable Type Length Preformed connectors Susceptibility to radiation References page 48190 7 481 90 EN FM 6 Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface 174 CEV 200 30 174 CEV 300 10 Modbus Plus Ethernet Modbus Ethernet Nominal 12 24 Limit 9 30 1 RJ45 port for 10baseT cable y 110 120 automatic detection 1 Ethernet 10baseT RJ45 type 10base2 BNC type 10base5 AUI type 1 Modbus Plus double single pair cable Vertical panel or horizontal plane On DIN ra
32. Micro PLC 100 240 V 24 V Power supply integrated on Premium PLC 100 240 V 24 V Via centralised display unit on Micro PLC or on TSX SAY 100 module and the diagnostics function of PL7 Micro PL7 Junior and PL7 Pro software 1 Defined as the time between the appearance of an input its processing by the PLC processor and the activation of an output on the same slave device 43613 EN FM 3 Description dimensions Micro automation platform AS i bus power supply module and unit The TSX SUP A02 power supply module and the TSX SUP A05 power supply unit integrate the special filters necessary for the AS i bus power supply These elements provide polarisation of the AS i bus and power the associated sensors within the limits of available power These supplies conform to PLC standards IEC 1131 1 and IEC 1131 2 in terms of radiation filtering and interference withstand The TSX SUP AO05 unit also has a 24 V output used to supply other elements which may or may not be connected to the AS i bus PLCs sensors actuators etc TSX SUP A02 power supply module It comprises 1 An AS i indicator lamp green indicating that the 30 V supply is present on the AS i bus 2 Two screw terminals AS i and AS i to connect the AS i bus and one terminal to connect the shielding when using a shielded bus cable 3 Three screw terminals for connection to the network 4 A primary voltage selector 110 120 V and
33. PLC object lists e Up down load programs and PLC data one program and up to 10 data files per protected RAM memory PCMCIA card The PLC provides the power supply to the FTX 117 Adjust terminal TSX 0720 10 RUN ERR 1 0 APP Execf Mod0 OK Example of TSX editor IWO 0 IWO 1 IW1 O IW1 1 Example of DAT editor Transfer list Format Card ADJ max 62 Example of DT i editor Q0 01F End of list Example of Frc editor References Dimensions page 43580 3 page 43580 3 The front panel of the FTX 117 Adjust terminal comprises 1 A connector for connecting a T FIX CB1 020 cable to the PLC 2 A back lit screen with 4 lines of 16 alphanumeric characters 3 A keypad with 35 keys 4 A slot for the type 1 PCMCIA memory card 5 Magnets on the rear of the terminal which are used to keep it in a vertical position on a metal support 6 Acarrying strap All functions can be easily accessed at any moment using 7 editors with the following menus e TSX has menus for displaying the type of PLC modifying displaying the PLC operating mode RUN STOP ERR naming the application and the presence of forced bits module diagnostics setting the internal clock of the PLC e DAT data editor used to access all variables in real time display modify or force valid variables access to the modification and display of Grafcet steps convert word objects into Hexadecimal ASCII
34. Premium MIA A __ I gt D P TSX 17 20 iji il Lin E ab ii E Bi ill i For characteristics Fipway network wiring system and connection accessories see pages 43597 2 to 43597 5 The operating principle of a Fipway network gives ensured constant network cycle times whatever the traffic and number of stations 2 to 64 This enables the Fipway network to be updated addition or removal of stations without changing the performance Maximum transmission time e Telegram TLG priority application messages are transmitted in less than 10 ms one telegram per station e Common words COM the database of common words is updated every 40 ms Shared Table the exchange table is updated every 40 ms e Uni TE message handling system Uni TE or standard application to application messages are normally transmitted in less than 80 ms 40 ms for stations with addresses below 32 Where there is a large amount of traffic some messages can wait for several cycles before being transmitted The network characteristics enable a maximum of 210 messages of 128 bytes per second to be transmitted The performance can be improved by inhibiting the Telegram service in the network Device 1 Cin Fipway network ma Device 2 CT2 CT2 With such network characteristics the response time at application level depends almost exclusively on the pr
35. Premium PLC platforms shared with that of TSX 17 or TSX PMX model 40 PLCs conforms to the OSI model Telegram 7 Application Common words shared table Uni TE Application to application communication Modbus 7 Uni TE 6 Presentation 5 Session 4 Transport TCP 2 Link Uni Telway WorldFip ISO 8802 3 ISO 8802 3 Ethernet Ethernet 1 Physical RS 485 WorldFip ISO 8802 3 ISO 8802 3 19 2 K bits s 1 M bits s 10 M bits s 10 100 M bits s Uni Telway Fipio Fipway Ethway Ethernet TCP Physical layer Ensures the physical transmission of data signals between 2 systems via a medium m Uni Telway is an isolated bus conforming to the RS 485 standard with a standard data rate of 19 2 K bps m Fipway conforms to the WorldFip standard and is a 1 M M bps baseband bus m Fipio conforms to the WorldFip standard and is a 1 M bps baseband bus m Ethernet TCP IP and Ethway not available on Micro conforms to standard 8802 3 and is a 10 100 M bps baseband bus Data link layer Ensures organized data transfer between two adjacent systems with error detection and correction m Uni Telway a fixed master manages access to the multidrop bus m Fipway conforms to the WorldFip standard with access via bus arbitrator m Fipio conforms to the WorldFip standard with access via bus arbitrator m Ethernet TCP IP and Ethway not available on Micro conform with CSMA CD bus Carrier Sense Multiple Access with Detection Collision ISO 8802 2 8802 3 standards AS roces for
36. RS 485 TSX PCX TSX SCY 21601 0 360 Uni Telway integrated 2 wire Premium Character mode channel ch 0 1 type III PCMCIA card slot channel 1 Modbus Jbus RS 232 D 9 signals TSX SCP 111 0 105 Uni Telway 0 3 19 2 Kbps Character mode RS 485 RS 422 compatible TSX SCP 114 0 105 1 2 19 2 Kbps 20 mA CL TSX SCP 112 0 105 1 2 19 2 Kbps Includes all the X Way drivers 1 CD ROM TSX CD DRV 12M Uni Telway Fipway Fipio Ethway for Windows 3 1 95 98 NT 2000 XIP ISAway for DOS and Windows 3 1 95 98 NT 2000 Uni Telway for TSX SCP 114 card in Windows 95 98 NT 2000 Weight kg Isolation of Uni Telway signals TSXP ACC 01 0 690 for bus length gt 10 m end of line adaptation bus cable tap links Tap link and extension of bus cable TSX SCA 50 0 520 end of line adaptation 2 channel tap link 15 way female SUB D connector TSX SCA 62 0 570 and extension of bus cable address coding and end of line adaptation Connection of an RS 232 C device TSX SCA 72 0 520 using Uni Telway protocol adaptation and isolation of signals end of line adaptation no address coding Please consult our specialist ctalogue Uni Telway bus 1 Product supplied with bilingual Quick Reference Guide English and French 2 With Micro PLC Schneider Electric References Micro automation platform Uni Telway bus Description Use Length Reference Weight From A kg Double Uni Telway bus 100 m TSX CSA 100 5 680
37. TMP DBGEF MAINO101 C 23 PL Fonctions en biblioth que Micro automation platform SDKC software Debugging the functions The function created must be generated under the debug format to be tested Once it has been inserted in an application and loaded to a PLC the execution of a function can be checked using numerous debug tools A specific function debug menu in C language accesses the following services m Breakpoint insertion m Step by step execution m Display of code with breakpoints shown m Display of data manipulations Functions library enhancement After developing generating then debugging the function the last step consists of generating a function family installation disk This enables the function library on the user s programming terminal to be enhanced Managing the versions allows the level of any functions installed on a station to be known at any time These functions can be used in all PL7 languages PL7 SDKC procedure creation software Description Function PL7 SDKC Procedure written in C software language with access extension to floating point functions Debug in PLC This software extension enables standard functions offered by PL7 Micro PL7 Junior and PL7 Pro version V4 TLX CD PL7 e P40M software to be extended It comprises e A set of 3 1 2 disks A bilingual user manual English and French This software is supplied with
38. TSX PLP 101 0 320 RAM type PCMCIA memory TSX BAT M01 0 010 card Cover for TSX 37 05 08 10 21 22 Sold in TSX RKA 01 0 150 empty slot 3 PLCs individual batches of 10 Gripper Memory extension cards TSX P CAP 0 030 PCMCIA type 1 1 Card previously loaded to enable the Micro application program to be updated without needing a programming terminal the program must be entirely contained in the internal RAM 2 One fan module for a TSX 37 05 08 10 2 1 22 configuration two fan modules for a TSX 37 10 21 22 configuration with mini rack TSX RKZ 02 Required for an ambient temperature between 60 and 70 3 Cover to be mounted in positions which do not hold a module to obtain IP 20 level of protection characteristics Dimensions mounting pages 43050 11 and 43050 12 page 43050 15 Schneider Electric Dimensions Micro Automation Platform mounting TSX 37 05 08 10 21 22 PLCs Side view Front view Mounting Bl 151 A E EZ A AS 5 0 140 5 9 erir 311 4 24 24 _Y 10831 c sees 132 5 2 l gt 152 3 a b Cc G TSX 37 05 028DR1 170 3 TSX 37 05 028DR1 159 2 TSX 37 08 056DR1 227 9 19 TSX 37 08 056DR1 198 9 TSX 37 10 028 128 164e01 170 3 282 7 TSX 37 10 028 128 164e01 159 2 TSX 37 21 22 e01 227 9 341 4 19 TSX 37 21 22 e01 198 9 1 Empty PLC 2 With screw terminal
39. Telefast 2 pre wired system ABE 7CPA 01 CPA11 43054 5 43054 2 Schneider Electric Positionning module for SSI absolute encoder 1 channel 200 kHz or 1 MHz Channel 0 5 V or 10 30 V SSI serial absolute encoder 8 to 25 bits or 5 10 30 V parallel output absolute encoder 8 to 24 bits with Telefast 2base ABE 7CPA11 2 x 24 V input capture In modulo mode 8 to 25 bits 0 a 33 554 431 points Read of bit number of absolute encoder frame Modulo and offset functions Inputs 2 capture inputs Comparison to the position value 4 thressholds causing activation of priority event triggered task Capture 2 capture registers on rising or failling edge of the physiqual inputs Via 9 way SUB D connectos for absolute encodeur Via 15 way SUB D 15 for capture et power supply encodeur 43313 5 04630 EN FM 3 Presentation description Counter channels on Discrete input module Integrated TSX CTZ modules Max no of channels Modicon TSX Micro Specifications References page 43054 4 page 43054 5 43054 EN FM 2 Micro automation platform Integrated counter channels and counter modules Counter functions are required for counting items or events grouping objects controlling input and output flow measuring the length or position of elements and measuring speed frequency or duration Micro PLCs provide 3 ways in which these functions of downcounting upcounting
40. The internal RAM memory can thus be reloaded with the contents of this Backup memory card This Backup function is not available if the application runs on a PCMCIA RAM or Flash EPROM memory card references Dimensions mounting pages 43050 13 and 43050 14 15 page 430 43050 EN FM 9 Centralized display Micro Automation Platform description TSX 37 05 08 10 21 22 PLCs Micro PLCs are equipped with a display block which groups together centrally all the data required for the control diagnostics and maintenance of the PLC and all its modules as well as simple man machine interface functions The centralized display provides m Display of the local or remote I O channel states I O of Nano PLCs m Display of devices on the AS i bus and AS i bus diagnostics see page 42718 2 m Display of diagnostics of faulty channels or modules m Display of internal data O bits O bit strings O word strings O program variables active steps application information etc m 4 digit multiple digital display Description The centralized display block comprises 1 Three blocks of 32 LEDs representing the slots in which the modules are installed 2 pl K ES oe P 3 in the base rack or mini extension rack 64 16 64 16 64 16 8 12 2 An information line consisting of LEDs which show the display operating modes 9 13 10 14 1115 3 A command push button which provides access to the various display operating is modes 1 2 6 10 14 4 A 4 Five L
41. Timers TMi 0 lt i lt 254 10 ms to 9999 ms mM 32 255 Up Down counters Ci 0 lt i lt 254 0 to 9999 word m 64 255 Timers PL7 2 Ti 0 lt i lt 254 m 8 255 Monostables MNi 0 lt i lt 254 16 steps m 4 255 LIFO or FIFO 16 bit registers Ri 0 lt i lt 254 m 8 255 Cyclic programmers DRi 0 lt i lt 254 16 steps The total number of timers TMi and Ti is limited to 64 255 Instructions on word and double word tables m Assignment in table E Arithmetic x REM E Arithmetic AND OR XOR NOT E Summons of the elements of a table SUM Comparison of 2 tables EQUAL EQUAL ARR E Search 2 FIND _EQW FIND_GTW FIND _LTW E MAX_ARW MIN ARW E Circular shift 2 3 ROL_ARW ROR_ARW E Tri 2 3 SQRT_ARW m No of occurrences of a value 2 3 OCCUR_ARW E Calculation of the length of the table 2 3 LENGTH_ARW Instructions on floating point words E Comparison gt lt lt gt lt gt E Arithmetic SQRT m Absolute value whole floating point ABS TRUNC m 16 bit integer conversion lt gt Floating INT_TO_REAL REAL_TO_INT E 32 bit integers conversion lt gt Floating DINT_TO_REAL REAL_TO _DINT m Floating lt gt ASCII conversion REAL _TO_STRING E STRING_TO_REAL m Conversion degree lt gt radian DEG_TO_RAD RAD_TO DEG E Rounding of a floating value in ASCII format ROUND E Assignment initialization of flo
42. a new packaging cycle Examples of up down counting In this example objects are upcounted or downcounted in a tunnel The system checks that a critical threshold is not crossed in order to detect any malfunction in the tunnel This up down counting application uses two sensors proximity sensors or photoelectric sensors linked to a threshold up down counter Each input sensor pulse increments the counter each output sensor pulse decrements it Crossing the authorised maximum threshold sets off an alarm In this example the length of objects travelling on a conveyor belt is measured in order to sort them This up down counting application follows this sequence a sensor detects the presence of the object on the conveyor belt While the object is on the belt the pulses from the generator linked to the forward movement of the conveyor belt are counted The number of pulses represents an image of the length of the object This measurement can then be compared to various minimum and maximum thresholds Example of up down counting with processing In this example the correct operation of a pump is checked by taking account of its rotation speed This speed should lie between a low threshold pump fault and a high threshold pump cut out The speed of the pump is measured by taking account of the pulses supplied by an incremental encoder or proximity sensor during a unit of time time base worked out by the TSX 37 22 PLC system The
43. a screw terminal block can accept bare wires or wires fitted with cable ends with closed or open tags The capacity of each terminal is m Minimum O 1 wire 0 28 mm2 AWG 23 without cable end m Maximum o 2 wires 1 mm2 AWG 17 with cable end or O 1 wire 1 5 mm2 AWG 15 without cable end or O 1 open or closed tag for wires of 1 mm2 AWG 17 Prewired cable with 20 flying leads gauge 22 0 324 mm2 Used for the simple and direct wire to wire connection of the I O of modules with connectors 1 to the sensors preactuators or terminals The prewired cable 3 comprises At one end a moulded HE 10 type connector 2 with 20 x 0 34 mm2 cross section wires in a sheath At the other end 4 flying leads differentiated by colour coding conforming to DIN 47100 TSX CDP 301 length 3 metres TSX CDP 501 length 5 metres TSX CDP 1001 length 10 metres Sheathed rolled ribbon cable gauge 28 0 08 mm2 Used to connect the I O of modules with HE 10 type connectors 1 to Telefast 2 connection and adaption rapid wiring interfaces 2 The cable 3 comprises 2 HE 10 type connectors 4 and a sheathed rolled ribbon cable with 0 08 mm2 cross section wires Bearing in mind the small cross section of the wire this method of connection is only recommended for low current I O 100 mA maximum per input or per output TSX CDP 102 length 1 metre TSX CDP 202 length 2 metres TSX CDP 302 length 3 metres Connection cable gauge 22 0 324 m
44. automation platform Master modules for AS i bus Diagnostics performed using the centralised display unit on the Micro PLC or using the centralised display unit on the TSX SAY 100 module of the Premium PLC can be completed using an FT2100 terminal or PC compatible with PL7 Micro Junior Pro software The terminal connected to the Micro Premium PLC is used for operational diagnostics of the TSX SAZ 10 and TSX SAY 100 master modules the AS i bus and the slave devices on the AS i bus Diagnostics is performed using a single screen divided into four sections providing information on Operational status of the TSX SAZ 10 or TSX SAY 100 module RUN ERR I O status Status of the AS i channel connected to the module Faulty slave Data relating to any selected slave profile parameters forcing etc AON In the event of an AS i module or channel fault a second screen can be accessed which clearly shows the type of fault which may be at internal or external level TSX SAZ 10 TSX SAY 100 AS i no 12001 NF C 63 850 AS i no 18801 NF C 63 850 M2 Operation 0 60 C Storage 25 70 C IP 20 Conforming to IEC 68 2 6 Fc tests Conforming to IEC 68 2 27 EA tests 31 AS i slaves 124 inputs and 124 outputs Depending on the PLC master task execution time 30 ms 60 ms 30 ms 10 ms 10 ms 60 ms By terminal block inside module polarity By 3 way SUB D connector locating device Power supply integrated on
45. block 3 With HE 10 type or SUB D connectors 4 Fixing holes for M4 screws Mounting for TSX FAN eeP modules mE ql 92 A Y A lt q Y Installation regulations 100 o LO 1 a u 100 3 m a SS Rall REE 3 2 2 2 LO 1 gt 50 mm 2 Switch gear or enclosure 3 Cable ducting or wiring cli Description Functions characteristics references pages 43050 2 and 43050 5 pages 43050 6 and 43050 7 pages 43050 11 and 43050 12 pages 43050 13 and 43050 14 Schneider Electric E Modicon Te eee A 43050 EN FM 15 Micro automation platform Discrete I O modules 32 inputs 32 outputs 32 outputs Inputs 24 V Outputs 24 V solid state 0 5 A Outputs relay 2A Ith Connection via screw terminal block supplied with the module Sensor voltage monitoring Type 2 Positive 2 wire 2 wire 3 wire PNP Preactuator voltage monitoring Configurable fallback of outputs Configurable fallback of outputs Yes Protected Non protected Positive 43051 9 0466Q EN FM 2 Schneider Electric 16 inputs 12 outputs Inputs 100 120 V Inputs 24 V Relay outputs 3 A Ith Relay outputs 3 A Ith Sensor voltage monitoring Sensor voltage monitoring Inputs 24 V Outputs 24 V 0 5 A Sensor voltage monitoring 32 inputs 32 outputs Inputs 24 V Inputs 24 V Outputs 24 V 0 1 A Outputs 24 V 0 5 A Co
46. close to the machine In addition to the standard Fipio services see pages 43301 3 to 43301 5 Micro TSX 37 21 22 and Premium PLCs allow exchanges of input and output variables with the bus manager PLC These exchanges are performed cyclically automatically and without the involvement of the application program at the same rate as the task for which the agent PLC has been configured For characteristics Fipio bus wiring system and connection accessories see pages 43597 2 to 43597 7 The application services supported by Micro TSX 37 21 22 and Premium Agent function PLCs are m Uni TE service X Way industrial message handling service suitable for operator dialogue diagnostics and control functions requests of up to 128 bytes m Application to application communication service which consists of the transmission of tables between 2 devices controlled by their respective application programs messages of up to 128 bytes m New periodic data exchange service for exchanging a 64 word table between the bus manager PLC and the Premium Agent PLC TSX 57252 RACK O POSITION 0 Each Micro Premium PLC Fipio Agent uses 64 MW consecutive internal words to Configuration y exchange periodic data The first 32 words are reserved for sending data to the a manager and the remaining 32 are reserved for receiving data from the manager ae PL7 Micro Junior Pro application specific screens allow the configuration of the Fipio SE C
47. comment of up to 222 characters A rung consists of 7 lines on Micro and 16 lines on Premium with 11 columns allowing a maximum of 10 contacts and one coil per line Program editor Ladder language The Ladder language editor offers several tools for constructing rungs in a user friendly way m A palette of graphic elements for direct access to the various graphic symbols of the language via the mouse or the keyboard contacts Boolean logic coils operation blocks predefined function blocks etc i Desk Ce ic eed a m A rung can be drawn without having to fill in each element m The language objects can be entered and displayed in either symbol or address format m The symbol and address of each object can be displayed simultaneously m A rung is constructed simply by selecting the symbol from the graphic palette and placing it in the correct position in the grid on screen m An automatic link line function optimizes the number of user actions The Ladder language editor is used to call up immediately the functions which assist data entry m Access to function libraries m Access to the variables editor m Cut copy paste Structured Text language is a sophisticated algorithmic type language which is particularly suitable for programming complex arithmetic functions table operations message handling etc Program structure section SR or event triggered task Structured Text language enables direct transcription o
48. current value obtained is compared to the two predefined thresholds in order to detect any anomaly 43054 EN FM 3 Specifications Micro automation platform Integrated counter channels and counter modules Physical inputs TSX DSZ discrete module Integrated counting TSX CTZ modules mua tr mam A ee Y EE ne Elec rical specifications www y m JALIN Type of counter module channel Number of channels Frequency on counter inputs Frequency limitation Event processing response time Processing response time in master task scan time 5 ms Sensor power supply Voltage monitoring Current Consumption Input Specifications 2 Type of counter module channel Nominal Voltage values Current Limit Voltage values Atstate 1 Voltage Current Atstate O Voltage Current Logic Input for nominal U impedance forU 2 4V RS 422 compatibilit Response time immunity when mechanical contacts used Type of input IEC 1131 conformit Proximity sensor compatibilit Connections pages 43054 6 and 43054 7 43054 EN FM 4 Functional flowchart of a counter channel Configuration l and adjustment Configuration IA IB and IZ KW MW parameters incremental encoder input Adjustment detector inputs parameters _ _ downcounting function Q LQW with Ba o IPres preset or reset input compare measurement Ena counting enable input
49. ensure high levels of resilience With their open ended redundant functions from a single ring structure to a double ring structure it is easy to create a fault tolerant Ethernet network which meets the specific demands of your industrial environment Characteristics pages 48190 3 to 48190 6 E Modicon Schneider Electric BE To Lanna aml anna Characteristics Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface Mechanical characteristics Models Operating temperature Relative humidity Dimensions L x H x D Degree of protection Approvals and conformity Electrical characteristics Models Types Interfaces Medium Connectors Operating voltage Redundancy Consumption at 24 V Line length Number of TF hubs in cascade in a ring Alarm relay Indicator lights References page 48190 7 Schneider Electric 499 NEH 004 10 499 NEH 041 00 499 NOH 005 10 C 0 to 60 10 90 without condensation 40 x 125 x 80 80 x 140 x 80 IP 30 UL CE CUL 1950 FCC part B CSA 22 2 142 CSA 22 2 213M class 1 Div 2 certification pending 499 NEH 004 10 499 NEH 041 00 499 NOH 005 10 Ethernet 10 Mbps Ethernet 100 Mbps Ethernet 10 Mbps 4 10baseT ports with RJ45 shielded connectors 4 100baseTX ports with RJ45 shielded connectors 3 10basel ports with RJ45 shielded connectors 2 10baseFL ports with BFOC connectors Twisted pair cables Twisted p
50. m Maintenance assistance m User guides FactoryCast configuration tool for the integrated WEB server only available on the TSX ETZ 510 module The FactoryCast software version gt 2 2 1 Supplied on the CD Rom with the TSX ETZ 510 module allows you to configure and administer the Web server embedded in the module It is common to the Micro Premium and Quantum automation platforms and is Windows 95 98 NT compatible It provides the following functions m Access security m Definition of the User names and associated passwords to access the Web pages m Definition of the access to the variables authorized in modification m Access to the PL7 application and to the Micro PLC data m Save restore a complete Web site m Transfer of Web pages created in local mode by the user on a PC compatible workstation to the TSX ETZ 510 module and vice versa 1 Memory that is insensitive to power outages and to PLC resets Schneider Electric Description Micro Ethernet Schneider Electric Micro automation platform Ethernet network and TCP IP Modem serial link The Ethernet TSX ETZ 410 510 modules are autonomous and thus do nat fit into a Micro PLC rack but fix onto a DIN profile or on AM1 PA perforated mounting plate The front of the TSX ETZ 410 510 modules are arranged as follows 1 Three display LEDs indicating the module status RUN ERR RX TX 2 Ascreened on label indic
51. network to dynamically obtain its configuration 2 Simple Network Management Protocol Network management protocol which is used to monitor a remote network by requesting the status of the stations and modifying their configuration performing security checks and observing various information linked to data transmission It can also be used to manage remote data bases and software 43312 EN FM 5 Functions continued Micro automation platform Ethernet network and TCP IP Modem serial link The Ethernet ETZ 410 510 modules for the Micro PLC accept the scanned l O service which is performed by the Premium or Quantum modules using the l O Scanning service TSX ETY 410e 510e 140 NOE 771 e0 Flow chart MW word table Premium Momentum ATV 58 i por LE i BoNo Th y O O Premium all Magelis iio oo This service is used to manage the exchange of remote inputs outputs on the Ethernet network after a simple configuration and without the need for specific programming Inputs outputs are scanned transparently with the assistance of read write requests according to the Modbus protocol on the TCP IP profile This principle of scanning via a standard protocol is used to communicate with any device supporting a Modbus server on TCP IP or with a built in Modbus Uni TE converter on TCP IP The Ethernet TSX ETZ 410 510 modules
52. or up down counting can be performed On the inputs of the discrete I O module located in the first slot of Micro PLCs or m Using the counter channels 11 and 12 integrated in TSX 37 22 PLCs or m With TSX CTZ counter modules installed in the available slots on Micro PLC bases Maximum number of counter channels permitted TSX 37 05 08 10 TSX 37 21 TSX 37 22 Counting 500 Hz on the inputs of discrete modules The first 4 inputs of the TSX DEZ DMZ eeee 28 32 or 64 discrete I O module located in slot no 1 enable two counter channels to be used 1 20 way HE 10 connector or screw terminal block depending on the model for connecting O Counter sensors or 24 V incremental encoder for channel 0 O Counter sensors for channel 1 O 24 V encoder power supply Counter channels 10 kHz integrated in TSX 37 22 PLCs TSX 37 22 PLC bases have an integral counter interface 2 channels which can be accessed via 1 Two 15 way SUB D connectors for connecting O Counter sensors or incremental encoder for channel 11 O Counter sensors for channel 12 O Auxiliary preselection input O Power supplies for auxiliary inputs sensors and incremental encoder The second connector can take the Telefast 2 ABE 7CPA01 wiring system to facilitate installation TSX CTZ 1A 2A 40 kHz and TSX CTZ 2AA 500 kHz counter modules The TSX CTZ1A 1 channel and TSX CTZ 2A 2AA 2 channels half format counter modules have on their front panel
53. outputs 2 Analogue extensions 3 inputs 1 output 3 1 Maximum 4 bases with remote discrete I O configuration maximum 3 bases with slave PLC configuration 2 Maximum 1 discrete extension 3 Maximum 3 analogue extensions I O extension module for Nano PLCs The TSX STZ 10 half format module can be inserted in position 4 which means that its use excludes integration of the TSX SAZ 10 AS i bus module Description Use Format Connection Reference Weight 1 kg Remote TSX 37 10 Half Via terminal TSXSTZ10 8 0 180 discrete TSX 37 21 22 block integrated I O extension PLCs in module module TSX STZ 10 1 Multilingual quick reference guide included as standard English French German Italian and Spanish Presentation page 43056 2 Schneider Electric 43056 EN FM 3 Micro automation platform AS i bus AS i is a bus for sensors and actuators Actuator Sensor interface lt is a deterministic bus with very short response times AS i is an open industrial standard supported by the AS i association This association includes European leaders in the sensor actuator PLC and connector technology markets AS i thus has the advantage of not being a proprietary network figuration AS interface DelxeL cso12R581 E Adressago HAMACA Configu HEJxvast02 P HP ZB2 BZ520 Wiring data is transmitted via a standard cable comprising a pair of non twisted non shielded wires with a cross section of 1
54. paste etc are available to the user Instruction List language is a language representing in the form of text the equivalent of a Ladder diagram It is used for writing Boolean equations and making use of the functions available in the language Program structure section SR or event triggered tasks A program in Instruction List language comprises a sequence of instructions from the following different families m Bit instructions for example read input n 3 LD I1 3 m Instructions on function blocks for example start timer n 0 IN TMO m Numerical instructions on single double and floating point integers for example perform an addition MW10 MW50 100 m Instructions on word tables character strings for example perform an assignment MW10 10 KW50 10 m Program instructions for example call subroutine n 10 SR10 Each instruction is composed of an instruction code and a bit or word type operand Program editor Instruction List language As in Ladder language instructions are organized into sequences of instructions equivalent to a rung Each sequence of instructions can be identified by a label Li with i being from 0 to 999 and accompanied by a comment of 222 characters maximum Each sequence of instructions is composed of one or more test instructions The result of these instructions is applied to one or more action instructions Objects can be entered and displayed in either symbol or addres
55. repli Iv Adressage Automatique Maintien lO Repli 40 m Configuration esclave 2 Macias Param tres 0 ds 2 3 43613 EN FM 2 Micro automation platform Master modules for AS i bus The AS i bus is configured using PL7 Micro Junior Pro software The utilities available are based on the principle of simplicity m Management of profile tables parameters and data by the master this management is transparent to the user m Topological I O addressing each AS i slave declared on the bus is assigned a topological address on the bus by the user This is transparent to the user m Each sensor actuator on the AS i bus is treated as an in rack I O by the Micro Premium PLC AS i bus configuration All devices on the AS i bus are configured implicitly using the following sequence of screens Declaration of the AS i bus master module m The TSX SAZ 10 module is always inserted and declared in position no 4 on TSX 37 10 or TSX 37 21 22 PLCs m The TSX SAY 100 module is inserted into any position on TSX P57 T PCX 57 PLCs except the position reserved for processors and power supply Configuration of the AS i slave devices Using the configuration screen it is possible to configure all the slave devices 1 to 31 ie all 248 I O Configuration for each device consists of defining according to case m Groupe Schneider AS i devices The user sel
56. terminal with a modem which supports a standard browser for the serial link O all Uni TE Modbus TCP IP devices ATV 58 drive Magelis terminals etc m The SNMP V1 network agent function All Ethernet modules integrate the MIB II standard Management Information Base RFC 1213 and the Ethernet Transparent Factory private MIB These are compatible with the main network administration software available on the market Schneider Electric 43312 EN FM 3 Functions Ethernet Ethernet link Micro automation platform network and TCP IP Modem serial link PC Internet browser LI Quantum h Y Modem link A Device T XBT F Magelis 1 2 3 4 5 and 6 See functions on page 43312 5 a Premium Ethernet TSX ETY 410e 510e module b Micro Ethernet TSX ETZ 410 510 module c Quantum Ethernet 140 NOE 711 e0 module 43312 EN FM 4 Schneider Electric Functions continued Schneider Electric Micro automation platform Ethernet network and TCP IP Modem serial link Services linked to Ethernet applications The TSX ETZ 410 510 modules integrate the services linked to the Ethernet applications 1 Integrated Web server services O IP configuration for the TSX ETZ 410 510 via standard browser on the Ethernet network or locally o Access security o PLC diagnostics system Function Ra
57. the TSX FPP 20 integrated link or via the TSX FPP 20 for FT 2100 PCMCIA PCMCIA card TSX FPM 100 module of TSX PMX card model 40 PLCs TSX FPC 10M for PC compatible Connection via the TSX FPG 10 ISA bus module of TSX 17 20 micro PLCs they access all devices in the X Way architecture The various X Way drivers are available on CD ROM TLX CD DRV M Description Number per Use Composition Reference Weight Premium 1 kg PLC Fipway card 1 with 57 10 Type III slot on 1 type III TSX FPP 20 0 110 1 with 57 20 Micro Premium PCMCIA 3 with 57 30 processor card 4 with 57 40 TPCX 57 10 30 TSX FPP 20 coprocessor TSX SCY 21601 module Communication See page For Premium PLC TSX SCY 21601 0 360 module 43592 3 1 isolated 2 wire RS 485 integrated channel Half duplex 1 slot for type Ill PCMCIA card Set of X Way Incluces all X Way drivers 1 CD ROM TLX CD DRV M z drivers Uni Telway Fipway Fipio Ethway under for Windows 3 1 95 98 NT 2000 TSX SCY 21601 PC compatible XIP ISAway under DOS and Windows 3 1 95 98 NT 2000 Uni Telway for TSX SCP 114 card JP under Windows 95 98 NT 2000 4 Terminal port under OS 2 Connection cables and accessories 2 Description Use Lengh Reference Weight From To kg Cables for TSX FPP 20 TSX FP ACC 4 1m TSX FP CG 010 0 210 PCMCIA card T junction 9 way miniature SUB D connector 3m TSX FP CG 030 0 410 TSX FP CG 010 030 connector roduct supplied with bilingual Quick Refer
58. the contacts in the input circuit are read by the PLC The Suitable for use with existing wiring with one contact on the safety consistency test carried out by the PLC program on the input contacts module and one contact for diagnostics this wiring enables global enables it to signal and locate precisely the faulty contact s reading of the state of contacts S4 to S7 and individual reading of When using less than 4 dual contacts the input terminals not in use must be contacts SO to S3 linked For example if contacts SO and S4 are not in use a bridge is required The consistency test carried out by the PLC program on the inputs between terminals 14 and 12 and terminals 13 and 15 enables it to signal any inconsistency with partial location of the fault Wiring diagram with single contacts Connecting TSX DPZ 10D2A modules in series 10006009 K3 _ k4 _ N Not all faults are detected A short circuit on a pushbutton or limit switch is The connection of safety relay outputs in series enables diagnostics for up not detected to 32 single or dual contact pushbuttons or limit switches The number of When using less than 4 single contacts the input terminals not in use must modules connected in series is limited by the number of slots available on be linked the Micro PLC For example if contact S5 is not in use a bridge is required between terminals 10 and 12 Specifications References page 43307 4 page 43307
59. thermocouples with cold junction compensation 16 channels 2or4 25 way SUB D Premium TSX PAY2e2 I O Safety module BG 12 Emergency stops 0 5 A 50 way SUB D 0113Q EN fm 7 References ABE 7H20Eeee 816462 816463 ABE 7H16CM21 Presentation compatibility page 14029 2 pag 14025 EN fm 2 Connection interfaces Telefast 2 pre wired system Passive connection sub bases Low cost sub bases Function No No of terminals For PLCs Length Type Reference Weight of per on of PLC of chan chan row connection connection nels nel number cable m kg Input 16 1 2 Modicon TSX 1 Screw ABE 7H20E100 0 330 or Micro Premium Output 2 Screw ABE 7H20E200 0 410 3 Screw ABE 7H20E300 0 480 Siemens S7 1 5 Screw ABE 7H32E150 0 360 3 Screw ABE 7H32E300 0 460 Miniature sub bases Function No No ofterminals LED Polarity Type Reference Weight of per on per distribution of chan chan row chan connection nels nel number nel kg Input 16 1 1 No No Screw ABE 7H16C10 0 160 or Output Yes No Screw ABE 7H16C11 0 160 2 2 Yes Oor24V Screw ABE 7H16C21 0 205 3 3 Yes O and 24 V Screw ABE 7H16C31 0 260 Input 16 1 1 Yes No Screw ABE 7H16CM11 0 160 and Output 1 2 2 Yes Oor24V Screw ABE 7H16CM21 0 200 1 81 8 Q these products have 2 commons connections which enable inputs and outputs to be connected to the same sub base at the same time Dimensions schemes age 14040 3 WW Telemecanique Schneider E
60. to value 0 Upcounting 2 thresholds and 1setpoint Up down counting 2 thresholds Events associated with each counter channel causing activation of the priority event triggered task Via screw terminals Supplied with module Via 15 way SUB D connectors Via 20 way HE 10 type connectors Via Telefast 2 pre wired system ABE 7CPA01 43050 8 1 Max 6 channels with TSX 37 05 08 10 8 channels with TSX 37 21 and 9 channels with TSX 37 22 see page Schneider Electric 0463Q EN FM 2 Counter modules for incremental encoder ask with cycle time 5 ms 1 channel 2 independent channel 40 kHz 40 kHz 500 kHz Per channel 5 24 V inputs for 1 Totem p le or RS 422 incremental encoder or for 24 V proximity sensors and mechanical contacts 3 x 24 V inputs enable preset and capture 1 24 V output line incremental encoder supply check In modulo mode 25 bits 0 to 33 554 431 points Inputs Counter enable counter preset capture current value and 2 setpoints Counter outputs to be applied to discrete output modules Downcounting 1 predefined SET RESET output Upcounting 2 SET RESET outputs 1 predefined and 1 adjustable Up downcounting 2 adjustable SET RESET outputs crossing a threshold crossing a setpoint present done enable done capture done Via 15 way SUB D connectors for incremental encoder inputs Via 20 way HE 10 connector for auxiliary and power supply inputs Via
61. 0 10 10mV 0 15 30 pA 0 15 20 uA 28 0 60 C 0 46 46 mV 0 46 46 mV 0 40 80 pA 0 40 80 uA 5 6 Temperature drift 10 C 0 068 0 054 0 8 Input impedance 2 2 MO 250 Q 54kQ 499 kQ Isolation Betw chann and bus 1000 None Betw chann and V rms 1000 None 0 V w r t earth earth Betw channels as Common point Common point Maximum excess voltage on inputs 430 15 15 Consumption mA See page 43311 2 output specifications m dule and integrated chann Integrated in Type of output modules TSX AMZ 600 TSX 37 22 Number of channels 2 1 Analog digital conversion SSS ee 11 from 0 to 8 20 mA Response time Hs 400 50 Maximum resolution 6 mV 3800 pts 6 mV 1900 pts 12 uA 1500 pts 40 mV Output load Maximum error at 25 C 0 5 50 mV 0 57 114 pA 1 5 at 60 C 0 58 58 mV 0 83 166 A 3 short circuit Maximum voltage without damage 30 7 5 Short circuit on OVoron5V Maximum temperature drift 0 107 05 Isolation Betw chann and bus 1000 None Betw chann and Vrms 1000 None 0 V w r t earth earth pet channel Common pat See page 4331 1 2 Consumption ma O Output current Maximum error a25 C MY at 60 m wo Maximum temperature drift ARO TO Type of protection Permanent short circuit 1 With the TSX ACZ 03 adjustment adaptor module For specifications of 8 24 V discrete inputs see page 4305077 2 Output for a maximum of 4 adjustment potentiometers internal or external 43053 EN
62. 031 0 140 cables module female SUB D via terminal port mini DIN 9 pin connector connector add TER eee TSX SCA 50 Uni Telway bus link 10m 4 5 TSX CX 100 connection box via terminal port D Blreremecanique gt Terminal port Uni Telway TSX ETZ 410 510 Uni Telway bus 1m TER port TSX P ACC 01 0 690 TSX P ACC 01 TER connection derivation bus module or Micro isolation signals for link cable box PLC buses gt 10m in length mini DIN end of line adaptation connector add bus cable derivation TER z o Passive derivation Uni Telway TSX ETZ 410 510 Derivation and TSX SCA 50 0 520 box derivation bus module prolonging of bus a mini DIN cable end of line DA 8 connector add adaptation TSX SCA 50 TER 1 Requires a TSX 37 10 20 21 PLC with a version gt 2 0 operating system supplied with a TSX ETZ CDN 003 link cable 0 35 m in length These modules should be supplied with 24 V see supply process page 43560 2 2 Supplied with CD Rom including the FactoryCast V2 2 1 software the Ethernet Transparent Factory Part A the user manual for the Ethernet TSX ETZ 410 510 modules 3 Add the letter U to the end of the reference for CSA 22 1 NFPA 70 and UL approved cables flame retardant 4 Free wire on the side of the TSX SCA 50 connection box 5 If the 0 35 m of TSX ETZ CDN 003 cable supplied with the TSX ETZ 410 510 modules is not suitable it is possible to use the TSX CX 100 cable 10 m in leng
63. 1 11 13 13 15 Functional diagram Emergency stop 1st contact S4 S5 S6 S7 2nd contact S0 S1 S2 S3 k oO Enable button S8 External start conditions ESC K4 safety output 1 2 K3 safety output 1 3 Power supply fuse F1 Output protection fuse F2 1 Emergency stop or limit switch activated 3 Error on contact S0 S3 2 Emergency stop reset or limit switch closed Specifications References Connections page 43307 4 page 43307 4 page 43307 5 Schneider Electric DCZ 43307 EN FM 3 Specifications Micro automation platform references TSX DPZ safety module Standards Whole machine cee eee EN 60204 1 or IEC 204 1 EN 292 machines Emergency stop device____________ EN418 Product E ae a EN 954 1 category 3 pr EN 954 2 EN 1088 parts of control systems or IEC 61508 SIL 2 PLC Specific requirements CS IEC 1131 2 or EN 61131 2 CSA 22 2 UL 508 aan Certifications BG INERIS INRS UL CSA 24 NTE E Maximum consumption MA lt 200 Protection via external F1 fuse Conforming to IEC 947 5 1 1 gl Consumption on internal 5 V mA lt 20 Power supply Isolation Nominal voltage Modularity Logic Inrush current Isolation between input and earth Power Modularity Limit operating voltage Max thermal current Ith Minimum current a c load d c load Response time Type of contacts External output protection via F2 fuse Isolati
64. 1 2 Signal Signal common Signal Signal Common configurable configurable 24V or 0 V 24V or 0 V 20 way HE 10 connector No No Screw Screw or spring Low cost version Miniature sub Compact size Type 2 input 1 Isolator fitted with cable bases 14025 2 14025 3 1 For Micro and Prenium PLCs 0113Q EN fm 2 Schneider Electric 817432 Discrete input and output 24V 24V 0 5 A 16 Signal 2 common connections between the inputs and the outputs 20 way HE 10 connector No Screw Miniature sub base 0 5 A Signal common 2 common connections between the inputs and the outputs Synergy with Tego Power and Micro PLC 14025 2 Schneider Electric Telemecanique 817433 J a au j ri mip i dl ike ma a a ene eS eee E FETS Removable electromechanical or solid state No Yes 24V solid state 5 24V 230 V electromechanical 5 A E M 2 A solid state 5 A th 16 8 passive inputs 8 relay outputs 1 Contact 1 N O and common 4 output channels 2 input connection points Miniature sub base Volt free or common per 4 channels Synergy with Tego Power and Micro PLC 14025 6 14025 5 0113Q EN fm 3 A D gt eee gt md gt A gt a gt a gt 0113Q EN fm 4 Connection interfaces Telefast 2 pre wired system Discrete input and output sub bases AS Electromechanical fixed Yes 2
65. 2 Step activity time Xi T 2 Indirect access Function blocks Timer monostable register TMi z Mi z Ri z R pon counter drum controller Ci Z Y DRI Z W oe on ll Description Use Description Reference Weight kg Portable mini Adjustment of Nano Micro LCD screen 4 lines of 16 T FTX 117 ADJ 02 0 380 terminal Premium PLCs characters 35 key dust 5 and damp proof keypad T FTX 117 ADJ 02 Power supply via PLC erminal port Protected RAM Back up lists of 32 K words T FTX RSM 3216 0 060 memory PLC objects 28 K useful words type 1 PCMCIA cards 128 K words T FTX RSM 12816 0 060 123 K useful words Battery For RAM type PCMCIA TSX BAT M01 0 010 memory card T FTX 117 ADJ 02 T FTX RSM e016 E 30 1 R read W write F force 2 On Micro Premium only 3 No forcing on Nano 4 Only certain system bits and words can be written 5 Includes the cable for connecting to Nano Micro Premium PLCs T FTX CB1 020 2 m long and multilingual installation guide Presentation page 43580 2 Schneider Electric py Modicon 43580 EN FM 3 Micro automation platform Power consumption of Micro PLC modules The power supplies incorporated into Micro PLC bases have sufficient nominal power to enable them to activate 60 of discrete inputs and or outputs simultaneously at state 1 At peak power these power supplies can activate 100 of discrete inputs and or outputs simultaneously at s
66. 2 wire 3 wire 2 wire S wire 0 45 kHz for an incremental encoder with phase shifted signals For characteristics of TSX DEZ DMZ eeee discrete input modules see page 43051 4 Up to 34 V for 1 hr in 24 hours For TSX CTZ 2AA module gt 6 8 mA U 3 V For TSX CTZ 2AA module gt 0 350 ky U 3V For TSX CTZ 2AA module lt 25 us state 0 to 1 lt 50 us state 1 to 0 A Ns A A A 1 2 3 4 5 6 Schneider Electric References Micro automation platform Integrated counter channels and counter modules Counter modules Type of input Counter frequency No of Reference Weight chan 1 kg 2 3 wire proximity sensors 40 kHz 1 TSX CTZ 1A 0 200 PNP NPN 24 V Incremental encoders 2 TSX CTZ 2A 0 210 25 V RS 422 10 30 V Totem Pole 500 kHz 2 TSX CTZ 2AA 0 220 TSX CTZ 1A TSX CTZ 2A 2AA Connection accessories Description For connection of Type of connectors Reference Weight connection to kg SUB D TSX CTZeA module High density TSX CAP H15 0 050 connectors counter sensors or encoder 15 way SUB D sold in lots of 2 TSX 37 22 15 way SUB D TSX CAP S15 0 050 integrated counter Telefast 2 Counter sensors and TSX CTZ A 2AA module ABE 7CPA01 0 300 ABE 7CPA01 connection 24 V power supply TSX 37 22 int counter sub bases Auxiliary inputs 20 way HE 10 ABE 7H08R10 0 190 24 V power supply and TSX CTZ 1A module 5 V 10 30 V encoder power supply 20 way HE 10 ABE 7H16R20 0 300 TSX CTZ
67. 21 22 PLCs These RS 485 type non isolated links use Uni Telway Master slave Modbus slave or character string Also TSX 37 10 21 22 PLCs integrate Modbus Master protocol 7 m PCMCIA format communication card for TSX 37 21 22 PLCS They have a dedicated slot for the PCMCIA format communication card Full duplex asynchronous serial link FIPIO Uni Telway or Modbus Jbus Modbus Plus and Fipway network m Ethernet TCP IP 10 100 MHz external modules The module connects to the terminal port of TSX 37 10 21 22 PLCs and has Uni TE and Modbus messaging It allows connection to an external modem using PPP protocol For further details see pages 43609 2 to 43599 5 Fan modules TSX FAN eeP fan modules installed above Micro PLCs ensure a forced air convection which creates a uniform ambient temperature within the enclosure and eliminates any hot spots which might exist Fan modules are required when the ambient temperature is between 60 C and 70 C Forced ventilation is used to eliminate hot spots 2 Three types of fan module are available 24 V 110 V and 220 V One fan module is required for a TSX 37 05 08 10 21 22 configuration two fan modules are required for a TSX 37 10 21 22 configuration with the TSX RKZ 02 mini rack 1 The TSX CTZ 1B module or the Modbus slave protocol require a Micro PLC with a 2 5 0 operating system installed with 2 4 2 PL7 Micro Junior Pro version software 2 For an ambient temperature of betw
68. 2A 2AA module Connection 5 V RS 422 encoder TSX CTZ eA 2AA module TSX TAP S15 05 0 260 interfaces for incremental encoder 10 30 V TSX CTZ eA 2AA module TSX TAP S15 24 0 260 Totem Pole encoder Connection cables Description From To Length Reference Weight kg Cable Integrated counter ABE 7CPA01 0 5 m TSX CCP S15 050 0 110 cross section 15 way SUB D sub base TSX TAP S15 ee 0 205 mm connector 15 way SUB D 1m TSX CCP S15 100 0 160 connector 2 5 m TSX CCP S15 0 300 TSX CTZ eA module ABE 7CPAO1or 2 5m TSX CCP H15 0 300 counter sensors TSX TAP S15 ee or encoder sub base 15 way high density 15 way SUB D connector SUB D connector Pre formed Auxiliary inputs 24 V Free end with 3m TSX CDP 301 0 400 cables with 20 power supply and labelled wires flying leads 5 V 10 30 V 5m TSX CDP 501 0 660 500 mA max encoder power supply moulded 20 way 10m TSX CDP 1001 1 210 HE 10 connector Pre formed Auxiliary inputs 24 V ABE 7H08R10 16R20 1m TSX CDP 102 0 090 TSX CCP S15 TSX CDP 001 connection power supply and Telefast 2 sub base cables 5 V 10 30 V 20 way HE 10 2m TSX CDP 202 0 170 100 mA max encoder power supply connector 20 way HE 10 3m TSX CDP 302 0 250 connector Connection Auxiliary inputs 24 V ABE 7H08R10 16R20 0 5 m TSX CDP 053 0 085 cables power supply and Telefast 2 sub base 500 mA max 5 V 10 30 V 20 way HE 10 1m TSX CDP 103 0 150 encoder power supply connector moulded 20 way 2m TSX CDP 20
69. 3 0 280 HE 10 connector 3m TSX CDP 303 0 410 5m TSX CDP503 0 670 y J 1 Product supplied with bilingual installation guide English and French TSX CDP 602 TSX CDP 603 Specifications Connections page 43054 4 pages 43054 6 and 43054 7 Schneider Electric DEZE 43054 EN FM 5 43054 EN FM 6 Connections Micro automation platform Integrated counter channels and counter modules Connection to integrated counter channels Connection examples for counter and auxiliary inputs Encoder 240 L 10 30 V power supply 250 l EA j 5V Sere 24 V input 220 Pp power supply oy B 0V 270 a ofa 3 TSX 37 22 23 Preset IPres11 l 20 Channel 11 E O BBB Sue ABE 7CPA01 160 Preset IPres12 140 lA A Channel 12 IA 24V 40 Counter GND sensor E ANDA DEN 2 124 V imputa food Jone supply 24V d 0V 270 Telefast 2 230 IPres11 Preset E 20 sO i IZ 16 IZ 24V 14 Z 1 Encoder 2 wire 2 TSX TAP S15 05 24 connector oa TSX TAP 15 05 TSX TAP S15 24 IB 109 1 IB 7 NC 1 NC 7 NC IB 24V 80 B Grane 2 Sup Ret 8 B 5V 2 NC 8 IB 24V 3 IZ 5V 9 NC 3 IZ 24V 9 NC 4 Z 10V OV 4 NC 10 OV lA 19 5 IA 5V 11 NC 5 lA 24V 11 NC lA 24V 40 A 6 IA 12 5V 6 NC 12 10 30 V 3 Cable with connectors TSX CCP S15 GND 4 4 TSX CAP S15 connector aa Connection to TSX DEZ DMZ discrete inp
70. 4 73 74 83 58 67 58 67 58 67 58 67 58 67 58 67 58 67 58 67 58 67 Q gt o y BS 9_ Y NJ Telemecanique J 14040 EN fm 3 Compatibility Type Micro platform Tego Dial Tego Power Premium platform Tego Dial Tego Power Quantum platform Tego Dial Tego Power Automation platforms Modularity of connection to the PLC 8 inputs 8 outputs 16 inputs 16 outputs 16 inputs 8 inputs 8 outputs 16 inputs 16 outputs 16 inputs 16 outputs 16 inputs 16 inputs 16 outputs 32 inputs 32 outputs 32 inputs 32 inputs 32 outputs Micro automation platform Tego Dial Tego Power installation system Tego Power components Compatible I O Tego Dialbase modules 81 8 O Tego Dialbase 161 Communication module or control splitter box with 8 1 8 O APE 1B24M APE 1B24E APP 1CH APP 2R4H1 H3 TSX DMZ 16DTK 1 TSX DMZ 64DTK TSX DMZ 64DTK 28DTK TSX DMZ 16DTK TSX DMZ 64DTK TSX DEY 16FK 32D2K 64D2K TSX DSY 32T2K 64T2K TSX DEY 16FK 32D2K 64D2K TSX DEY 32D2K 64D2K 16FK TSX DSY 32T2K 64T2K 140 DDI 353 00 10 140 DDI 853 00 140 DDO 353 00 10 140 DDI 353 00 10 140 DDI 853 00 140 DDI 353 00 10 140 DDI 853 00 140 DDO 353 00 10 1 For the connection of a second Dialbase APE 1B24M use 2 x TSX DP ee3 connecting cables 43320 FR fm 2 NJ Telemecanique Schneider Electric Connecting components Control splitt
71. 4 V OSO nv 230 V 2 A th 00 NO 1 N O contact and common Volt free 3 A th 1 N O contact 20 way HE 10 connector Yes Screw or spring Miniature sub base Bistable relay 14025 4 Yes Volt free 5 V 150 V 230 V 5 A th 1 N O contact and common Yes or common per 8 channels MW Telemecanique Electromechanical or solid state Yes No 24 V solid state 5 V 24V 230 V E M 2 A solid state 6 A electromechanical 16 1 N O contact No Screw Miniature sub bases Common per 4 channels 14025 5 14025 6 No 5 Va 150 V nv 230 V Depends on relay mounted 0 5to 10 A 8or 16 2to3 Signal Polarities No Screw or spring Isolator and fuse Schneider Electric Electromechanical removable Yes SOV TOO Vv 230 V 5A th 1 C O contact or 1 N O contact and common No Screw 8 A th 2to6 1 C O contact or 2 C O contacts and common Volt free or common per 8 channels 14025 5 4 channels Schneider Electric Solid state fixed Yes 2AN from 0 5 to 2 A Signal and 0 V Yes Screw or spring Fault signal 14025 4 125 mA No Isolator and fuse indicator 14025 3 817439 Discrete input A T bi ej afe i e s El ae LL a s E Jl o pm m _ PeeePe eRe ERERHE EERE ue TETTE 0 5 A 125 mA 3 2 Signal Signal can be 24Vand0V _ isolated Pr
72. 43100 2 to 43100 1 7 1 VO TSX AMZ 600 analog modules require a Micro PLC with a 25 0 operating system installed with 2 4 2 PL7 Micro Junior Pro version software references Dimensions mounting pages 43050 13 and 43050 14 page 43050 15 W Modicon Schneider Electric E AI Functions continuea q Vf HE Ct OK TSX 37 08 21 22 TSX 37 21 22 TSX RKZ 02 CDescription characteristics pages 43050 2 to 43050 5 pages 43050 11 and 43050 12 Schneider Electric Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Counting positioning Counter modules Micro PLCs offer several ways of counting m Using 500 Hz discrete inputs 2 up down counter channels with upcounting downcounting or up down counting functions with or without detection of direction of operation m 10 kHz counter channels integrated into TSX 37 22 PLC bases 2 10 kHZ fast counter channels with 1 channel having down counting functions as above m Counting positioning TSX CTZ modules eA from 40 500 kHz or TSX CTZ 2B from 200 kHz 1 MHz 7 These half format modules are inserted in the available slots in the base rack For further details see pages 43054 2 and 43054 7 43050 2 to 43050 5 Communication Micro PLCs offer several possibilities m Integrated communication which offers cost effective dialogue functions via the terminal port for TSX 37 05 08 10 PLCs or via the terminal and man machine interface ports for TSX 37
73. 5 to 2 5 mm This cable provides a power supply to the sensors and actuators It is installed directly onto the machine without the need for any special components splitter terminal blocks etc All topologies are possible The maximum length of the segment without repeaters is 100 m with repeaters it is 200m Physical installation as the medium cable is standard it can be installed in all industrial applications Dust and damp proofing and a locating device are added when a special AS i cable is used Hardware installation software tools integrated into PL7 products allow a choice of bus components to be made and to set the parameters for these components within the control system configuration This is transparent to the user Maintenance all services available on the interface and the programming of In rack I O can be found in PL7 tools with diagnostic screens channel topology syntax associated mnemonics forcing of variables debug zone etc Impact on the machine lowers cost and volume of wiring reduces size of floor standing enclosures eliminates control wiring ducts increases and simplifies the capacity for developing and adapting the machine Greater availability and adaptability of subassemblies HEJXUJK103534AS HE XxZ SDA22D32 HE xZ SDA40D2 PHEJABE 8544SBB0__ HE LFIKO9BWRQOCA WMEJXS1 M30AS101
74. 5m 170 MCI 020 10 cables tee 170 XTS 020 00 1m 170 MCI 020 36 170 XTS 020 00 3m 170 MCI 021 20 10m 170 MCI 020 80 TSX MBP 100 Drop cable 10 0 2m TSX MBP CE 002 PCMCIA card with male 9 way miniature SUB D connector connector Local site tap 8 3m TSX MBP CE 030 0 340 990 NAD 230 00 10 6m TSX MBP CE 060 0 530 Communication Junction box 9 2 4m 990 NAD 211 10 0 530 TSX MBP CE 030 060 module for 990 NAD 230 00 10 Momentum 6m 990 NAD 211 30 0 530 I O sub bases 1 Product supplied with bilingual Quick Reference Guide English and French 2 For other Modbus Plus network connecting cables and accessories please consult your Regional Sales Office Characteristics Connections page 43599 3 page 43599 4 Schneider Electric 43599 EN FM 5 Presentation Micro automation platform application services Fipio bus Agent function software setup April 5000 IL ia Series 7 Premi Fipio bus Intelligent l XAL control sensors B station As i bus Micro TSX 37 21 22 or Premium PLCs fitted with a TSX FPP 10 PCMCIA card on their integrated communication channel are agents on the Fipio bus The bus manager is a TSX P 57 153 253 353 453 T PCX 57 203 353 TSX Series 7 model 40 or April 5000 PLC The Fipio bus enables l O to be remotely located close to the devices to be controlled Momentum Altivar etc The Agent function enables offline processing by locating a Micro PLC
75. 60 for 60 I O loading or at 30 for 100 I O loading 2 For 0 1 x 106 operations 3 For 0 15 x 106 operations 4 For 0 2 x 106 operations 5 For 0 25 x 106 operations 6 For 0 3 x 106 operations 7 For 0 5 x 106 operations 8 For 0 7 x 106 operations 9 For 0 8 x 106 operations 10 For 1 x 106 operations 11 For 1 2 x 106 operations 12 For 1 5 x 106 operations 13 For 2 x 106 operations 14 For 3 x 106 operations 15 For 5 x 106 operations 16 For 10 x 106 operations Connections pages 43051 11 to 43051 13 Schneider Electric References Micro automation platform Discrete I O modules Nature of Input voltage Modularity no Format Connection Reference Weigh current of channels kg 24 V 12 Half Via HE 10 type TSX DEZ 12D2K 0 160 i positive log connector 1 i IEC type 2 32 Stand Via screw terminal TSX DEZ 32D2 0 290 block supplied TSX DEZ 12D2 24 V 12 Half Via screw terminal TSX DEZ 12D2 0 230 positive log block supplied IEC type 1 or negative log 100 120 V 8 Half Via screw terminal TSX DEZ 08A4 0 230 IEC type 2 block supplied ad 200 240 V 8 Half Via screw terminal TSX DEZ 08A5 0 230 Nature of Output voltage Modularity no Format Connection Reference Weight current of channels kg 24 V 0 5 A 8 Half Via HE 10 type TSX DSZ 08T2K 0 180 solid state protected connector 1 protected Via screw terminal TSX DSZ 08T2 0 240 block supplied 32 Sta
76. C M void far pascal MAX _TABW adrTABLE TAB adrSCAL MAX PL SDK_END_FUNCTION_NAME adrTABLE far pwTable short far pcPhyTable short Resultat TABLE short TailleTab LASSEO1 H gt AINO101 H gt amp TAB pointeur s TIDEMAX_ARW pointeul in Micro automation platform SDKC software C language function development software also called SDKC is a PL7 Micro PL7 Junior and PL7 Pro software option lt enables new functions to be developed internal code written in C language and extends and completes the standard set of functions offered by PL7 software SDKC software also integrates a creation and management service for families of functions so they can be integrated in the PL7 library Finally it can be used to generate the function which ensures the protection of PL7 applications by reading a signature in the PCMCIA card inserted in the PLC C language development software is a genuine tool for managing the entire function which has been created m A user friendly creation interface integrated in PL7 with automatic file organisation m Powerful debug and test tools m Management of compatibility and software version for the functions created m Generation of disks for the subsequent installation of functions on other development stations Management of function families The software enables different function families to be defined These functions also known as EF are classed according to fa
77. E6 7 LIBELLE7 8 LIBELLES 9 LIBELLE9 LOOP SELECT PID loop selection screen PID loop control screen The CCX 17 operator panel can manage up to 9 PID controllers Installation of the man machine interface function is simple and is performed as follows m The PID MMI function is activated on each scan of the Micro or Premium PLC unconditional call up UP ane m A single call up of the PID_ MMI function manages all the PID loops in the Micro qe E COT or Premium PLC application TS s PV_DEV DN OUT_MAX OUT_MIN PID loop adjustment screen PID function Universal serial parallel structure Limited by the number of analogue modules and by the memory data capacit Adjustable from 10 ms to 5 min 20 s Smooth changeover manual automatic Direct measurement in 0 10 000 format Continuous output in 0 10 000 format Adjustable from 100 100 Integral action Time adjustable from 0 2000 s Integral saturation Pure integration operation Time adjustable from 0 1000 s on measurement or deviation No man machine Internal RAM Cartridge Internal RAM Cartridge interface 1 08 JO EE E E 1 2 Process control functions with pulsed outputs PWM function Pulse width modulation Adjustable from 0 327 67 s Execution time ms 06 05 SOS SERVO function Position control of bidirectional motorised actuator With position feedback with discrete servo control with adjustable hysteresis With
78. EDs O RUN PLC run stop o TER traffic on the terminal port O I O I O fault o ERR processor or application fault O BAT battery fault or no battery Functions characteristics references Dimensions mounting pages 43050 6 and 43050 7 pages 43050 11 and 43050 12 pages 43050 13 and 43050 14 page 43050 15 43050 EN FM 10 W Modicon Schneider Electric A AAA ETE Characteristics Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Micro PLCs have been developed to conform to the national and international standards concerning electronic devices for industrial control systems m Specific requirements for programmable controllers functional characteristics resistance robustness safety etc IEC 61131 2 CSA 22 2 UL 508 m Merchant navy requirements from the main European bodies BV DNV GL GOST LR RINA RRS m European directives low voltage electromagnetic compatibility C marking m Electrical qualities and self extinguishing capacity of insulating materials UL 746C UL 94 etc See page 43311 3 Temperature Operation Storage Relative humidity Operation Storage Altitude Mechanical withstand Resistant to vibrations Resistant to shocks Resistant to electrostatic discharge Withstand to electrostatic discharge Resistance to HF interference Resistant to electromagnetic fields Resistant to rapid transient bursts Resistant to shock waves Resistant to damped oscillatory waves
79. FM 6 Schneider Electric Micro Automation Platform Integrated analog channels and analog I O modules References Type Number of Range of Resolution Reference Weight of input channels of input signal 1 kg High level 8 10 V 0 10 V 11 bits TSX AEZ 801 0 200 analog with signal common point 0 20 mA 4 20 mA 12 bits TSX AEZ 802 0 200 Isolated high 4 10 V 0 10 V 16 bits TSX ASZ 414 0 210 TSX AEZ 802 level analog 0 5 V 1 5 V 0 20 mA thermocouples 4 20 mA B E J K L N R S T U temperature Pt 100 Ni 1000 2 or 4 wire probes Type Number of Range of Resolution Reference Weight of outputs channels outputs signals 1 kg Analog with 4 10 V 0 10 V 11 bits TSX ASZ 401 0 200 common point signal TSX ASZ 401 2 10 V 11 bits TSX ASZ 200 0 200 0 20 mA 4 20 mA signal or 12 bits TSX ASZ 200 AMZ 600 TT Z TSX CCP S15 TSX BLZ H01 Schneider Electric Type Type of input of outputs 4 high level 2 high level analogs analogs with common point with common point Range of Resolution I O 10 V 0 10 V 11 bits 0 20 mA signal 4 20 mA or 12 bits Reference 1 TSX AMZ 600 Weight 0 240 Description Use Adaptation Analog I O channels module integrated in TSX 37 22 direct connection SUB D type TSX 37 22 integrated connectors analog and counter I O lots of 2 channels Telefast 2 Integrated analog I O connection base channels TSX 37 22 Description For co
80. Isolation Betw channels and ground Betw channels and int log Module type Number of inputs Connection Nominal input values Voltage Current Sensor supply ripple included Input limit values At state 1 Voltage Current At state 0 Voltage Current Input impedance at state 1 Configurable response time State 0 to 1 State 1 to 0 IEC 1131 2 conformity Proximity sensor compatibility 2 3 wire Isolation resistance Type of input Consumption Dissipated power Isolation Betw channels and ground Betw channels and int loa References pages 43051 9 and 43051 10 Schneider Electric Micro automation platform Discrete I O modules Specifications of 24 V input modules 1 TSX DEZ 12D2 TSX DMZ 28DR TSX DEZ 12D2K TSX DEZ 32D2 TSX DMZ 16DTK 12 16 12 32 Screw terminal block HE 10 connector screw terminal block 24 pos HE 10 connector enclosed terminal block 24 neg log 24 positive logic EA CA A 19 30 possible up to 34 V limited to 1 hour per 24 hours 0 1 7 0 AE Yes type 1 Yes type 2 Yes type 1 Q A3 lt 3 I lt lt lt gt 10 at 500 See page 43311 2 TSX DEZ 12D2 2 7 TSX DEZ 12D2K 2 7 TSX DMZ 28DR 4 5 TSX DEZ 32D2 6 1500 50 60 Hz for 1 min OM nm Resistive 9 lt rms lt rms 1500 50 60 Hz for 1 min TSX DMZ 28DTK DMZ 28DT 2 gt gt O N o oo 2 TSX DMZ 64DTK HE 10 connect
81. KS lt 4 Response time State 0 to 1 50 Hz 11 18 60 Hz ms 9 16 State 1to0 50 Hz ms 11 24 60 Hz ms 10 22 IEC 1131 2 conformity IS Yes type 2 Yes type 1 Yes type 2 Proximity sensor compatibility Yes 2 wire Isolation resistance gt 10 at 500 V Type of input IS Capacitive Consumption See page 43311 2 Isolation Betw channels and V rms 2000 50 60 Hz for 1 min ground Betw channels and int V rms 2000 50 60 Hz for 1 min log 1 Characteristics at 60 for 60 I O loading or at 30 for 100 I O loading References Connections pages 43051 9 and 43051 10 pages 43051 11 to 43051 13 43051 EN FM 6 mM Modicon__ Schneider Electric Specifications continued Micro automation platform Discrete I O modules Specifications of solid state output modules 1 Module type TSX DSZ 08T2K TSX DMZ TSX DSZ 08T2 TSX DMZ 28DT TSX DSZ 32T2 28DTK Nominal Voltage 24 24 output Current 0 5 values Tungsten filament lamp 10 Limit Voltage 19 30 possible up to 34 V limited to 1 hour per 24 hours output Current values for U 30 or 34 V 0 625 Logic Positive current source Leakage current at state 0 Residual voltage lt 0 5 lt 2 for accidental disconnection of the 0 V module lt 0 3 for 0 5 A Min load impedance 48 Response From state 1 lt 0 5 time 2 From state 0 lt 0 5 Switching frequency on inductive lt 0 6 LI4 load Built in Against overvoltages By Zener diode protection Agains
82. Micro automation platform TSX 37 05 08 10 21 22 PLCs 2 1 equipped with discrete 3 2 equipped with discrete 2 1 equipped with discrete I O module I O module a O O F 2 92 120 60 88 124 Emergency stop and limit switch monitoring 96 remote I O 4 Nano PLCs or Input 24 V input 115 V 8 12 or 16 channels with or without DEL with common or 2 terminals per channel 8 ou 16 channels 5 V TTL 24 V 48 V a 115 ou 230 V 2 terminals per channel 2 half format modules 8 inputs 12 bits 10 V 0 10 V 8 inputs 12 bits 0 20 mA 4 20 mA 4 differential inputs multirange 16 bits high level thermocouples temperature probes 4 output 11 bits sign 10 V 2 outputs 11 bits sign 10 V 0 20 mA 4 20 mA 4 inputs 2 outputs 12 bits 10 V 0 10 V 0 20 mA 4 20 mA 3 Nano analogue extensions Control loops 3 integrated functions PID PWM pulse width modulation et SERVO discrete valve 2 x 500 Hz channels using discrete inputs 2 half format modules 1 or 2 x 40 kHz channels 2 x 500 kHz channels for incremental encoders Totem p le or RS 422 1 channel 1 MHz for SSI absolute encoder 1 x RS 485 terminal port Uni Telway master slave Modbus 1 x RS 485 terminal port slave or character string protocol Modbus master slave or Ethernet TCP IP external module Single task cyclic or periodic multi task cyclic or periodic master task fast task Event triggered 1 to 8
83. OPC Server e An OPC Server software receiving requests from an OPC Client and retransmitting them to the PLCs e Low level drivers for communication with Modicon Telemecanique PLCs e An OPC Client allowing to check the communication between the different elements connected e A simulator allowing to debug Client applications and this without automate connected e The electronic setup documentation OFS software can be integrated in control system architectures such as the one shown below Ethernet TCP IP 7 OFS Server station A Database 5 symbols scy 4 file prj 7 x i l i 6 O gt l 3 i Premium Modbus Plus 3 Quantum Fipway 3 Momentum Micro 1 PC running OFS software including the OPC Server 2 PC running the Client application which accesses the PLC data via OFS 3 Communication networks linking the PC which supports OFS software with the PLCs 4 OPC communication protocol 5 Modbus on TCP IP communication protocol 6 Uni TE on TCP IP communication protocol Depending on the type of use the Client application and OFS software can be located on the same PC or on 2 different PCs and 2 linked by a TCP IP Ethernet network 7 PL7 software generates PLC variable symbol export files These export files symbols scy should be integrated in the OPC Server Concept variables can be accessed directly in the project file prj of
84. R1 _ 1 10baseT port RJ45 type Integrated Web server Reference Weight Diagnostic Webuser page kg yes TSX ETZ 410 0 280 yes 8 Mb TSX ETZ 510 0 280 yes z 171 CCC 980 e0 0 042 yes z 171 CCC 960 e0 0 042 170 ENT 110 00 0 070 TSX ETY 110 0 370 yes 1 4 Mb TSX ETY 110 WS 0 370 yes TSX ETY 410 0 340 yes 8 Mb TSX ETY 410 0 340 140 NOE 771 00 0 345 es 8 Mb 140 NOE 771 10 0 345 1 Add the letter U to the end of the reference for CSA 22 1 NFPA 70 and UL approved cables flame retardant 2 For example a TSX Series 7 PLC equipped with a TSX ETH 107 Ethernet module 48190 EN FM 7 Presentation performance References page 43592 3 43592 EN FM 2 Premium automation platform Fipway network The Fipway network is an open local area network for communication between the various Micro Premium and TSX Series 7 PLCs using the X Way services Communication conforms to the FIP standard with access via a bus arbitrator Micro TSX 37 21 22 and Premium PLCs can be connected to a Fipway network using a Fipway PCMCIA card which is inserted in each processor or into the TSX SCY 21601 Premium communication module Supported X Way services see pages 43301 3 to 43301 5 are e Uni TE services e Distributed database COM or Shared Table e Telegram service only available when the PCMCIA card is inserted in the processor e Application to application communication Ethernet TCP IP ol el el el e o ff
85. RS 485 terminal port RS 232 D RS 422 compatible loop 3 integrated port Size 4096 characters max Data 7 or 8 bits Stop bit 1 or 2 bits Parity bit Stop on silence Reception echo Repeatistchar echo ee Auto LF AA Back space Even odd or none Beep Flow byXon Xoff mgmt RTS CTS dela Stop on reception End of message PSR management DCD carrier Parameters which can be accessed in configuration mode 1 For characteristics of the communication module integrated channel see page 43591 2 2 With the TSX P57 3e3 453 processor data rate up to 115 Kbps during program uploading 3 Point to point or multidrop link Schneider Electric References Micro automation platform Asynchronous serial links Asynchronous serial link elements character mode Description Protocol Physical layer PLC Reference Weight 1 kg Integrated link Character mode RS 485 Micro See page 43050 13 on processor Uni Telway non isolated Modbus RTU TSX PCX Please consult our specialist catalogue Premium Communication Character mode 1 isolated TSX PCX TSX SCY 21601 0 360 module Uni Telway RS 485 Premium Modbus integrated chan TSX SCY 21601 channel 0 1 type Ill PCMCIA card slot channel 1 Type Ill PCMCIA Character mode RS 232 D 9 signals TSX SCP 111 0 105 cards for Uni Telway 0 3 19 2 Kbps TSX 37 21 22 Modbus PLC TSX PCX RS 485 RS 422 TSX SCP 114 0 105 Premium processor compatib
86. SX P57 1p3M 8056 on TSX P57 2p3M T PCX 57 203M 16248 on TSX P57 3p3M 453M and TPCX 57 353M Si 128 bit system Xi Grafcet step bits 96 on Micro TSX 37 10 128 on Micro TSX 37 21 22 1024 3 on Premium XMij 64 macro step bits on Premium PLC 1 j function block bits 1 XKk bits extracted from internal words systems constants from l O common networks Indexed objects E i MW j bits inputs outputs and internal E Mpi mW j internal words single double length and floating E Kpi mWj constant words single and double length and floating point E MWi MW j table of internal words Trigonometric instructions E angle expressed in radian SIN COS TAN E arc ASIN ACOS ATAN Character string instructions E Assignment of a character string m Comparison gt lt lt gt lt gt E Conversion ASCII lt gt 16 bits integer STRING_TO_INT INT_TO_STRING m ASCII conversion lt gt 32 bit integer STRING_TO_ DINT DINT_TO_STRING m Delete insert replace extract search for a sub string DELETE INSERT REPLACE MID FIND E Concatenisation comparison of 2 strings CONCAT EQUAL_STR E Character extraction LEFT RIGHT E Length of character string LEN Instructions on program E Call return of subroutines SRi RETURN E Jump to a label JUMP E Halt program execution HALT m Masking unmasking of events MASKEVT UNMASKEVT Word objects E MWi MDi MFi
87. T 2100 FTX 517 terminal or PC compatible 1 Limited to 128 bytes with Micro Premium PLC programming port For other limitations please consult our specialist catalogue References pages 43594 6 and 43594 7 43594 FR_EN FM 2 Schneider Electric Characteristics continuea Micro automation platform Uni Telway bus Performances o The Uni Telway bus cycle time depends on ms m The number of devices polled datalink addresses m The data rate 400 m The turnaround time of each device 4 m The number length and type of messages 300 5 BCT Bus Cycle Time is the interval between two polls to the same device 1 9 6 Kbps 200 2 19 2 Kbps 100 The above curve gives the Uni Telway cycle time as a function of the number of slaves operating at 9 6 Kbps or 19 2 Kbps with a typical turnaround time of 5 ms per device excluding messages 1 4 8 12 16 20 24 27 The following table shows the time to be added in ms to obtain the true BCT value as a function of the traffic N Number of usable characters Time ms Exchanges 9 6 Kbps 19 2 Kbps Master to slave 244 1 2N 1 17 0 6N 1 Slave to Master 19 1 2N 7 12 0 6 N 1 Slave to slave 44 2 3N 1 29 1 15N 1 1 N Number of usable characters corresponding to the messages to be exchanged In a distributed control system architecture the application to application response time depends not only on the communication system but also on m The pro
88. Terminal port TER Uni Telway Master Slave or Modbus slave protocol A Cover for accessing the power supply terminals al Two discrete modules with 16 inputs and 12 outputs placed in the first and second slot positions 1 to 4 o Cover for accessing optional battery N Available slot 00 Reset button Selection of modules to be inserted in addition to the 16 input 12 output module present at rack no 1 Type of module to be inserted Discrete Inputs Outputs Preventa safety module Analog I O Counter positioning channels Functions pages 43050 6 and 43050 7 Schneider Electric 8 inputs 12 inputs 32 inputs 4 outputs 8 outputs 32 outputs 16 inputs outputs 28 inputs outputs 64 inputs outputs 4 or 8 inputs 2 or 4 outputs 4 inputs and 2 outputs 1 incremental code channel 2 incremental code channels 1 absolute encoder channel characteristics pages 43050 11 and 43050 12 Connection Connector Format Standard Half Max number of modules N Term blk Insertion possible references Dimensions mounting pages 43050 13 and 43050 14 15 page 430 43050 EN FM 3 Presentation description selection Micro Automation Platform TSX 37 10 PLCs Compact and modular TSX 37 10 PLCs differ in their supply voltage and the type of discrete I O module fitted in the first slot Each TSX 37 10 configuration comprises a rack which integrates a power supply 24 Vor
89. WM or SERVO adaptations depending on the type of actuator for discrete control The PWM function provides the required adaptation to control a pulse width modulation actuator via a discrete output The SERVO function provides the required adaptation to control a motorised actuator with UP DOWN control provided by a discrete output It has a position feedback input to execute servo control These two functions are installed in cascade on the PID controller function Schneider Electric Functions Micro automation platform specifications Process control of semi continuous processes The CCX 17 industrial operator panel displays and controls all the PID controller parameters which can be modified without having to program the Micro or Premium PLC application program The PID_ MMI man machine interface function included in the PL7 Junior software provides an application program on the CCX 17 industrial operator panel for controlling and adjusting PID loops It enables the CCX 17 operator panel to manage m Selection of a PID loop m Display and control of that PID loop m Adjustment of the PID loop parameters This man machine interface function is easily installed for any man machine interface application on the CCX 17 operator panel The three preconfigured screens enable the required operations to be performed on any PID controller LIBELLE2 MOD 1 LIBELLE1 2 LIBELLE2 3 LIBELLE3 4 LIBELLE4 5 LIBELLES 6 LIBELL
90. X T PCX 57 20 30 coprocessor Description Connection Ref Reference Weight no 1 kg Communication module for Modbus Plus network 2 170 PNT 110 20 0 110 O ARR AA Momentum I O base units on Momentum l O 1O TOA A base units or ee _ Connection accessories 2 aia ANGE mem Description Use Ref Reference Weight Peet mam CE no kg Modbus Plus IP 20 tap for tap link 5 990 NAD 230 00 0 230 IA daa local site connection tee taps IP 65 tap for tap link 6 990 NAD 230 10 0 650 connection tee supports 1 RJ 45 connector on front panel IP 20 tee with 2 RJ 45 connectors 7 170 XTS 020 00 0 260 for Modbus Plus cable and 1 9 way SUB D connector for tap link devices Line 2 impedance adaptors for local site 11 AS MBKT 185 terminators tap IP 20 990 NAD 230 00 sold in lots of 2 2 impedance adaptors for local site 11 990 NAD 230 11 tap IP 65 990 NAD 230 10 2 impedance adaptors for tee 12 170 XTS 021 00 IP 20 170 XTS 020 00 Fixing kit for For fixing on DIN rail for 990 NAD 230 12 IP 65 local tap 990 NAD 230 10 site tap Wiring For fitting trunk cables and 043 509 383 tool drop cables in local site tap Connecting cables 2 Description Use Ref Length Reference Weight From To kg Modbus Plus Local site tap Local site tap 3 30m 490 NAA 271 01 trunk 990 NAD 230 00 10 150m 490 NAA 271 02 cables 300m 490 NAA 271 03 450m 490 NAA 27104 L 1500m 490 NAA 271 06 PE Drop IP 20 IP 20 tee 4 0 2
91. X AEZ 801 1 2 o Jpop so TSX AEZ802 1 2 po Jeo TSX AEZ 414 1 2 a ps Js TSX ASZ 401 1 2 a po jo TSX ASZ 200 1 2 A ja piso Counting TSX CTZ 1A 1 2 E o ioo ee TSX CTZ 2A 1 2 Ee ce ee TSXCTZ2AA 1 2 ra ly rr gt t lp Communication TSX STZ 10 1 2 o Piso S TSX SAZ 10 3 1 2 pro TSX MDM10___ A 195 po TSX SCP 111 is TSX SCP 112 EA f A TSX SCP 114___ A pio f TSX FPP 10 pesao pp TSX FPP 20 P30 TSX MBP 100__ a 220 TSXPACCO1_ A diso Terminals FTX ADJ 11702 _ po IE XBT H811050__ AAA Consumption by voltage Total current mA C C C lt lt lt power supplies Nominal current 2800 400 Peak current 3200 power supplies Nominal current Peak current 3200 1 The first value corresponds to the module consumption with 60 of inputs and or outputs at state 1 simultaneously The second value is for 100 of inputs and or outputs at state 1 2 24 V sensor voltage provided by the 100 240 V power supply on basic configurations is limited to supplying approx 100 inputs In excess of this use a process power supply see page 43560 3 3 Consumption on 30 V of the power supply for the AS i bus 50 mA typical 100 mA max 43311 EN FM 2 Schneider Electric
92. a Microsoft Visual C software package registration card Target PLC extension Reference Weight kg PL7 Micro Junior Pro Micro Premium TLX L SDKC PL7 40M 0 930 Schneider Electric Presentation Micro automation platform functions OFS data Server software OFS software OPC Factory Server uses the OPC OLE for Process Control standard which allows data processing applications known as Clients supervisors databases spreadsheets to access data internal variables in Schneider Electric PLCs Nano Micro Premium Momentum Quantum TSX Serie 7 April OFS software is a multi PLC data Server which enables several communication protocols to be used by supplying Client application programs with a set of services for accessing the control system variables This software is aimed at two types of user in particular e End users who wish to develop applications on a PC which will need to access PLC data In this context it is possible for example to create Client applications supervisory control screens Excel tables etc with access to a number of PLCs connected to the PC supporting these applications e Suppliers of control system or industrial data processing products supervision man machine interfaces etc wishing to develop within their standard products their OPC Client application which will be able to access data stored in PLCs via the OPC Server The OFS offer comprises e A tool for configuring the
93. air cables or redundant fibre optic ring 1 x 5 way V 18 32 safety low voltage 9 6 57 6 safety low voltage 18 32 safety low voltage Power supply Power supply and fibre optic ring 80 typical 200 typical 160 typical 130 max 270 max 350 max 100 max with twisted pairs Fibre optic 3100 max max 10 000 Twisted pairs 100 max max 330 Power supply fault Ethernet network fault or communication port fault volt free contact 1 A max at 24 V Power supply data exchange collision and line status via communication port A 48190 EN FM 3 Characteristics continued Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface Mechanical characteristics Models Operating temperature Relative humidity Dimensions L x H x D Degree of protection Approvals and conformity Electrical characteristics Models Types Interfaces Medium Connectors Operating voltage Redundancy Consumption at 24 V Line length Number of TF switches in cascade in a ring Alarm relay Indicator lights References page 48190 7 48190 EN FM 4 499 NES 071 00 499 NOS 071 00 O 0 to 50 10 90 without condensation 105 x 130 x 105 IP 20 UL CE CUL 1950 FCC part B CSA 22 2 142 CSA 22 2 213M class 1 Div 2 certification pending 499 NES 071 00 499 NOS 071 00 Ethernet 10 Mbps and Ethernet 100 Mbps 5 10baseT 100baseTX ports with shielded RJ45 connect
94. ale 25 way male Uni Telway 1m Included with TSX P ACC 01 Uni Telway 2m T FTX CB 1020 5m T FTX CB 1050 Character mode 3m T SX PCD 1030 1 4 15 way male SUB D connector 5 8 way female mini DIN connector 6 9 way female SUB D connector Schneider Electric 0 100 0 190 0 170 References continuea Micro automation platform Connecting cables for PCMCIA cards and TER AUX ports Micro Premium Device to be Physical Protocol Length Reference Weight PLCs connected link kg TER AUX DTE terminal RS 232 Uni Telway 2 5m TSX PCU 1031 0 140 ports Slave PC minimum 1 2 continued DTE terminal RS 232 Character mode 3m TSX PCX 1030 0 170 printer Uni Telway 3 Slave PC without RTS 2 DCE terminal RS 232 Character mode 3m TSX PCX 1130 0 140 Modem M SI Uni Telway 4 USA Europe 3 HN eem FT 2100 RS 485 Uni Telway 2 5 m TSX PCU 1031 0 170 terminal minimum 2 CCX 17 RS 485 Uni Telway 2 5 m XBT Z968 0 180 panel oooo gt A XBT terminal 4 083588880 l TSX SCY 21601 TSX SCA 50 RS 485 Uni Telway 3m TSX SCY CU 6030 0 180 communication T junction box 2 wire module isolated integrated 5 port Modbus Jbus 3m TSX SCY CM 6030 0 180 y 3 a sovervmiteeson AA S TSX SCA 62 RS 485 Uni Telway 3m TSX SCY CU 6530 0 200 2 channel 2 wire subscriber isolated socket 6 RS 485 RS 485 Character mode 3m TSX SCY CM 6030 0 180 terminal 2 wire isolated End of connecting cable fitted w
95. all application transfer and modification services in online mode The memory is backed up by a removable battery integrated in the memory card m Flash EPROM type memory card Used when the debugging of the application program is complete this card enables one global transfer only of the application and avoids the problems of backup via battery A third type of card can also be used to store files Battery backed RAM type memory card or battery backed RAM and Flash EPROM Used particularly in association with the Modem link these are used to extend the processor s internal memory and also to store recipe or log files for later consultation via a telephone link The RAM memory is backed up by a removable battery integrated in the memory card Another type of PCMCIA memory card is available m Backup type memory card for TSX 37 21 22 PLCs Previously loaded with the application program this card is used to reload the application program into the internal RAM memory and the internal Flash EPROM memory of the processor without requiring the use of a programming terminal Program loader The TSX PGR LDR module is designed to simplify duplicating or updating applications on Nano and Micro PLCs without the need for a programming terminal An application 15 K words maximum in internal RAM can be transferred from a PLC in the TSX PGR LDR module and saved within it then transferred from the TSX PGR LDR module in a PLC The front panel of
96. alues Voltage Current Limit values Voltage At status 1 Voltage Current At status O Voltage Current Input impedance Acceptance time O to 1 status 1 to 0 status Input type IEC 1131 conformity Detector compatibility Micro automation platform TSX CTZ 1B absolute encoder positioning module TSX CTZ 1B 4 V 5 10 30 8 to 25 bits 200 000 150 max encoder module 10 max encoder module 24 N Oo PO ES 19 30 wave included up to 34 for 1 hour in 24 gt 11 gt 3 U 11 V lt 5 a5 oO lt 50 lt 50 0 Resistive Type 1 sensor 2 wire 3 wire 24 V with the following specifications WN waste voltage at status 1 lt 7 V NM switched current lt 2 5 mA E residual current gt 1 5 mA 1 Using an absolute encoder with parallel outputs requires the Telefast 2 ABE 7CPA 11 adaptation base This base is used to multiplex up to 4 absolute encoders Module type Read frequency Comparative function Capture measure function Modulo function Offset function Checks Description References page 43313 2 page 43313 4 Schneider Electric This multiplexing is controlled by the Micro PLC discrete outputs TSX CTZ 1B Depending on mode mM 200 kHz in slow mode m 1 MHz in fast mode 4 thresholds each linked to 1 maskable EVti event activation upon event tasks and to 1 position bit in relation to the upper lower threshold 2 capture inputs and 2 capture registe
97. ask Debugging the application specific functions The debug screens for the application specific functions are accessed from the I O configuration screen by clicking on the position in which the module has been defined when the terminal is in online mode These screens are used for m Displaying and modifying the state of the I O m Forcing the I O m Displaying and modifying the current values Diagnostics The debug screens provide access to the general module or channel diagnostics These screens identify Internal module faults External faults generated by the application e g range overrun for an analog module With version 2 V4 0 of PL7 the Premium platform system diagnostics are extended It is possible to monitor system bits and words as well as to display associated time stamped messages automatically without the need for additional programming This monitoring applies to the system elements processor memory tasks etc in rack I O and remote I O on the Fipio bus 43100 EN FM 11 Functions continued rL PRO APP5725F R f rences crois es LH Eichier Edition Services Yue Outils AP Debug Options Fen tre 2 la x IV Bits Estraits Y Objets d une voie IV Objets d un SFB DFB I Tableaus Y Objets R seau J Instance d un DFB Rep re M11 Symbole Trig_prod_c Objets r f renc s U R R E MAST Macro0 PAGEO X03P1 W MAST RemplirRemplissage TOP R MAST
98. ating words E Find maximum minimum value in floating tables MAX_ARR MIN ARR Time management instructions E Read timer update RRTC WRTC SCHEDULE m Read time and date of stop PTC m Read current day DAY_OF_WEEK E Addition removal of a period of time at a date time of the day ADD_DT SUB_D ADD_TOD m Difference between 2 dates with without time between 2 times DELTA_DT DELTA_D DELTA_TOD E Conversion of a time period TRANS_TIME E Difference between a time period date with character string TIME_TO_STRING DATE_TO_STRING TOD_TO_STRING DT_TO_STRING Logical instructions on words and double words E Assignment in word indexed word bits string m Logics AND OR XOR NOT E Circular shift to the left and the right SHL SHR ROL ROR Arithmetic instructions on words and double words E Arithmetics REM SQRT ABS E Comparison gt lt lt gt lt gt M Increase decrease INC DEC m Extraction of weak words strong words LW HW E Concatenation of 2 words CONCATW Instructions on bit tables m Assignment between tables lt gt tables word lt gt tables double word lt gt table E Logic operations AND_ARX OR_ARX XOR_ARX NOT_ARX COPY_BIT E Bits copy table lt gt word table BIT_W W_BIT E Copy of bits table lt gt double words table BIT_D D BIT E Calculation of the length of the bits table LENGTH_ARX Character string
99. ating the module s MAC address default address set in the factory 3 Amini DIN connector for terminal port TER address 4 An RJ 45 connector for Uni Telway auxiliary port RS 485 serial link RS 485 address 5 An RJ 45 normalized connector for connecting to the Ethernet network 10 100baseT address A 9 pin male SUB D connector for RS 232 serial link Modem A screw terminal block for connecting to the external power supply 24 V A support plate enabling it to be fixed to the module COON O The TSX ETZ 410 510 modules support two kinds of exclusive TCP IP connections m By Ethernet network via 10 100basel RJ 45 interface see page 48190 7 for accessories and connection cables m By Modem via RS 232 serial link see page 43606 2 for accessories and connection cables The TSX ETZ 410 510 modules are connected to the Micro PLCs 7 TSX 37 10 21 22 via m The terminal port TER or the auxiliary port AUX m The PCMCIA RS 485 TSX SCP 114 serial link Flow chart The wiring chart opposite corresponds to one of the methods of connection The TSX ETZ 410 510 module is attached to the Micro PLC via its terminal port TER or AUX 1 TSX PCU 1031 Uni Telway connection cable between a compatible PC and the TER port of the TSX ETZ 410 510 module 2 TSX ETZ CDN 003 connection cable 0 35 m cable supplied with the TSX ETZ 410 510 module between the module rep RS 485 and the TER AUX port of the Micro PLC The TSX CX 100 cab
100. ation communication service is particularly suitable for m Sending alarm messages from a PLC to a supervision station m Exchanging data tables between two PLCs controlled by the application programs of the transmission and destination device m Sending broadcast messages to all stations and devices Service Ethernet TCP IP Ethway 7 Fipway Fipio Uni Telway Size of application 256 bytes 256 bytes 128 bytes 128 bytes 240 bytes 2 application messages Note The application to application messaging service can be used between stations connected on different Ethway Ethernet TCP IP Fipway Fipio or Uni Telway networks on the same multi network architecture Schneider Electric The telegram service available with Fipway is a special case of application to application messages It enables short messages to be transmitted and received on a priority basis The maximum size of messages transmitted via telegram is 16 characters A telegram from a Micro Premium PLC is transmitted immediately by the SEND_TLG transmission function without waiting for the end of the scan A telegram is received by Micro Premium PLCs using the RECEIVE_TLG reception function in m The event triggered task processed as soon as the message is received in the network cara m The fast task or master task when scanning the RECEIVE_TLG function A PLC can only process one telegram at a time The telegram service is suitable for short and priority messages S
101. ation converter software The application converter software for SMC PLCs is a PL7 Junior and PL7 Pro software option It enables parts of or in certain cases the entire existing SMC PLC application to be reused with Micro Premium PLCs The converter generates instructions in PL7 language which are functionally identical to the original instructions If the application has been archived using VPSOFT programming software version 3 02 minimum for SMC PLCs it is possible to translate the program and comments and retrieve the entire database variable symbols and comments If this is not the case the program only can still be converted once it has been transferred with VPSOFT software Program conversion is possible for SMC 200 500 SMC 23 35 and SMC 50 600 PLC applications The SMC converter provides the following functions e Selection of the application in the directory where SMC applications are stored e Selection of the program to be converted sequences to be converted e Code and data analysis associations are suggested for SMC variables with PL7 correspondence bits words double words or reals e Code and variable conversion in order to generate a PL7 equivalent e Report which shows the user the conversion success rate associations and causes of non conversion when applicable e Target configuration for displaying or entering a configuration required for arranging variables in PL7 It is possible to convert only the SMC database
102. ay block 3 State of the 4 device inputs 4 State of the 4 device outputs 1 When the TSX SAZ 10 module is in position 4 the upper position 3 can only receive a TSX AeZ eeee analogue or TSX CTZ eee counter half format module Schneider Electric References Micro automation platform connections TSX SAZ master module for AS i bus AS i bus module Description Protocol Number of I O Reference Weight kg AS i bus AS i 31 devices thus TSX SAZ 10 0 180 master module 248 I O maximum for TSX 37 10 21 22 PLCs Connection accessories Description Connection to cable Type and number of Reference Weight connectable cables kg Connection Via vampire clip 2 ribbon cables XZ SDE1113 0 070 TSX SAZ 10 modules for AS i bus yellow for ribbon cable 2 ribbon cables XZ SDE1133 0 070 1 for AS i bus yellow 1 for separate supply black Cover for XZ SDP 0 030 connection module Description Supply Length Reference Weight kg Ribbon cables For AS i bus 20m XZ CB10201 1 400 for AS i bus yellow 50 m XZ CB10501 3 500 XZ SDP 100 m XZ CB11001 7 000 Other AS i accessories Please consult our specialist catalogue Yellow cable TEST veto or black cable 1 AS i cable locking collar 2 AS i bus cable ribbon with locating device or round brown blue Schneider Electric 42718 EN FM 3 Software setup Param tres g n rauz sur d f aut Mode de
103. ble service Ethernet TCP IP Ethway Fipway Fipio Uni Telway COM es 1 es Shared table yes 3 These services are mutually exclusive and are recommended for the periodic broadcasting of status variables without loading the application program For transmission of events application to application communication with confirmation is more suitable Note The COM service or Shared Table service remains local to a Fipway network Each network has its own distributed database The Shared Table service is only available on Micro and Premium PLCs 1 This service is not available on the Micro and TSX 17 20 2 O or 4 common words for TSX model 40 stations with address 0 to 31 or for TSX 17 20 stations with address 0 to 15 3 This service is not available on the Micro and TSX 17 20 43300 EN FM 4 W Modicon Schneider Electric E VA PE Application service Micro Automation Platform continued X WAY communication This consists of sending word tables between 2 devices using the user application program For the following types of PLC m Micro Premium transmission and or reception is via the DATA_EXCH text type data exchange function m TSX 17 and TSX PMX model 40 transmission and or reception is via a TXT text block or an OFB Uni TE function block T f FME El Premium Word table EXCH DATA gt EXCH_DATA Exchange of data tables MW Lane The application to applic
104. card RS 232 422 485 or current loop serial link with Fipway Modbus Plus network Fipio bus Agent function or Modem PPP RS 232 serial link Event triggered 1 to 16 events with 2 priority levels memory 20 Kword internal protected RAM memory Extension via PCMCIA card up 64 Kwords 128 Kwords file storage sensor power supply or 24 V depending of model 16 or 32 inputs 24 V depending on model 12 or 32 outputs 24 V depending on model Via HE 10 connector Schneider Electric 04600 EN FM 3 Presentation Micro Automation Platform description TSX 37 05 PLCs selection The TSX 37 05 PLC comprises a rack which integrates 100 240 V power supply a processor including a 11 Kword memory program data and constants 1 Flash EPROM backup memory a TSX DMZ 28DR discrete I O module 16 inputs and 12 relay outputs and an available slot The available slot can accept m 1 standard format discrete I O module of any type m 2 half format discrete I O safety analog I O or counter modules The TSX 37 05 PLC comprises ok 2 slot rack N Centralized display block 9 Terminal port TER Uni Telway Master Slave or Modbus slave protocol D Cover for accessing the power supply terminals al Discrete module with 16 inputs and 12 outputs placed in the first slot positions 1 and 2 O Cover for accessing optional battery Available slot gt 00 O al N 00 Reset but
105. cations The drivers for connection to X Way and Modbus networks TSX DRV 12M The setup documentation on CD Rom Supplied on CD Rom this software operates autonomously on a PC Nevertheless export files for variables generated by PL7 or ProWORX development software need to be present The direct link with Concept applications requires Concept software version 2 1 to be installed on the same station OFS software for PC compatibles minimum configuration Pentium 266 MHz processor 64 Mb of RAM memory is compatible with Windows 95 with Service Pack 1 and DCOM Windows 98 Windows NT 4 0 with Service Pack 5 or Windows 2000 operating systems Description Function Reference Weight KG OFS data Enables the development of Client applications TLX CD eOFS 25M 7 0 160 Server accessing PLC data Micro Premium Momentum QA software Quantum TSX Serie 7 April via the OFS Server update Server software User s manual Setting multilingual manual FR EN and DE for OFS data TLX DM OFS 25M Server software paper format 1 To order a site licence for 1 station replace e by none character licence 10 stations 10 licence 20 stations 20 licence 200 stations UN 43105 EN fm 3 Presentation Micro automation platform description functions FTX 117 Adjust terminal The FTX 117 Adjust pocket terminal is used for adjusting Nano Micro Premium PLCs It is used to e Read modify and force valid parameters e Save and retrieve
106. cessing equipment Bull DPX2 100 computers under SPIX ES Digital PDP11 computers under RSX Micro VAX under VMS Hewlett Packard HP9000 computer running under HP UX References pages 43594 6 and 43594 7 Schneider Electric Connections TSX 17 20 ia 5 2 Device tt 10 3 Bl Je 083828880 A CCX 17 IA 8 ii mM bale E OF E i Premium 4 TSX OSY 21601 Micro automation platform Uni Telway bus Adaptor E lis A Far IS rl ies mm A L La E TSX SCP 114 PCMCIA card jot H i TSX PMX model 40 6 TSX CSA ess bus cable double shielded twisted pair The shielding must be TSX SCA 50 passive T junction box matches the impedance when it is TSX SCA 62 passive 2 channel Uni Telway subscriber socket is used for coding the address of two connected devices and matching the impedance when TSX SCA 60 passive terminal block used for intermediate devices which have the appropriate connections ATV 45 Masap drives It is used for coding passive terminal block used for end devices which have the appropriate connections ATV 45 Masap drives It is used for coding the address TSX LES 64 74 cable connectors for extensions to the Uni Telway bus used to connect PLC processors which have an integral Uni Telway port as standard model 40 PLCs They are used for coding the address of the connec
107. cessing times of the message source and destination devices ot on y m The degree of asynchronism between the bus and processor cycle times Uni Telway bus Bor Device 2 Ce CT2 Device 1 CTA CT1 This response time must be evaluated by the designer of each application according to the devices which are connected Y The processing time of a device may vary from one to two cycle times depending on the degrees of asynchronism BCT Uni Telway bus cycle time CT1 Device 1 bus cycle time CT2 Device 2 bus cycle time Characteristics References page 43594 2 pages 43594 6 and 43594 7 Schneider Electric DEZE 43594 FR_EN FM 3 Connectable devices Micro automation platform Uni Telway bus Micro Premium PLCs Micro Premium PLCs provide various ways of connecting to the Uni Telway bus 1 Via the integrated port on the processor or coprocessor The AUX 1 port 8 way mini DIN has one non isolated RS 485 serial link channel maximum distance 10 m 2 Via the integrated port on the TSX SCY 21601 module This module has one isolated RS 485 serial link channel Half duplex multiprotocol including Uni Telway 3 Via multiprotocol PCMCIA card A slot on the processor of TSX 37 21 22 Premium PLCs or on the coprocessor and on the TSX SCY 21601 module accepts the following multiprotocol cards m TSX SCP 114 PCMCIA card Isolated RS 485 RS 422 link This type of card corresponds to the Uni Telway stan
108. ching inputs these are inputs l1 0 to l1 3 The principle is that on a pulse which is shorter than the PLC scan the pulse is stored and processed on the next PLC scan The pulse is taken into account when the input changes state rising and or falling edge depending on the selected configuration Inputs which can be configured as event triggered inputs these are inputs l1 0 to l1 3 On command events the application program is diverted directly to the event processing associated with the input causing the event The event is taken into account when the input changes state rising and or falling edge depending on the selected configuration Inputs which can be configured as up down counter inputs these are inputs l1 0 to l1 3 Depending on the software configuration these inputs enable the creation of up to 2 up down counter channels each of which can execute one of the following functions independently upcounting function downcounting function up down counting with or without direction discrimination RUN STOP command input I1 8 can be set to control the RUN STOP command on the PLC This is taken into account on a rising edge ASTOP command via an input has priority over the RUN command via the terminal or network Program and data backup input input l1 9 can be set to back up the application program in the Flash EPROM memory in the internal RAM and the first 1000 words MWi maximum on a rising edge Alarm output
109. ckViewer o Communication diagnostics function o Access function to the PLC data and variables Data Editor o Download of Uni TE PL7 applications O Graphic object editor only on TSX ETZ 510 O display of predefined Web pages o User Web pages only on TSX ETZ 510 2 Scanned inputs outputs service performed from the Premium or Quantum PLC I O Scanning function 3 Uni TE messaging in TCP IP in Client Server mode o Remote terminal Terminal transparence see page 43300 3 4 Un TE messaging in TCP IP in Client Server mode o Conversion of Modbus requests to Uni TE requests going to the Micro PLC and vice versa for the reply 5 TCP IP messaging gateway to Uni TE 6 API calling called only for Modem link Standard Ethernet services for TSX ETZ 410 510 The TSX ETZ 410 510 modules conform to the following standard protocols m BOOTP attribution of IP address via a server also for addressing by default or from a PC equipped with a standard browser m DHCP 1 automatic reconfiguration by replacing a faulty module FDR function m SNMP 2 network management protocol The TSX ETZ 410 510 modules integrate the standard MIB II and the private Ethernet Transparent factory MIB 1 Only for Ethernet link Bootstrap Protocol protocol for starting up terminals or stations without a disk via centralized management of network parameters Dynamic Host Configuration Protocol protocol which allows a station connected to a
110. conversion 11 bits sign of output values TSX 37 22 PLCs integrate as standard a high level analogue interface with 8 input channels 0 10 V and one 0 10 V output channel This interface enables the PLC to meet the requirements of applications which require analog processing but where the performance criteria and characteristics of an analog input module cannot be justified The various functions of integrated analog channels are as follows m Scanning of input channels by solid state multiplexing normal or fast and acquisition of values m Analog digital conversion 8 bits and filtering of input measurements m Updating the digital output value by the processor m Analog digital conversion of the output value m Processing dialog faults with the PLC and in particular setting the output to fallback state m Supplying a reference voltage for potentiometers either external or included in the TSX ACZ 03 adjustment adaptor module It is possible to link the TSX STZ 10 I O extension module installed in position 4 of the base to up to 3 high level Nano analog I O modules 3 input channels 1 output channel per module For further details see pages 40055 2 et 40055 3 and pages 43056 2 and 43056 3 1 Requires a PLC with a version 2 5 0 operating system Installation of the TSX AMZ 600 involves version 2 4 2 PL7 Micro Junior Pro software Schneider Electric Micro Automation Platform Integrated analog channels and analog
111. crew ABE 7R08S111 0 244 per group of 4 channels spring ABE 7R08S111E 0 244 Bistable 2 Volt free Screw ABE 7R08S216 0 250 Spring ABE 7R08S216E 0 250 10 1 N O 5 Volt free Screw ABE 7R08S210 0 352 Spring ABE 7R08S210E 0 352 16 5 1 N O 2 Contact common Screw ABE 7R16S11 0 352 per group of 8 channels Spring ABE 7R16S111E 0 352 10 1 N O 5 Volt free Screw ABE 7R16S210 0 547 Spring ABE 7R16S210E 0 547 Common per Screw ABE 7R16S212 0 547 group of 8 chan Spring ABE 7R16S212E 0 547 on both poles 1 A fault on a sub base output Qn will set PLC output Qn to safety mode which will be detected by the PLC 2 Can only be used with modules with protected outputs Dimensions schemes page 14029 2 page 14040 3 1 4025 EN fm 4 MY Telemecanique Schneider Electric 816469 816471 References Connection interfaces Telefast 2 pre wired system Plug in relay sub bases No of Term For Isolation Input Type Reference Weight chan inals relay PLC connection of nels channel type application connection kg 16 2 ABS 7E Yes Volt free Screw ABE 7P16F310 0 850 ABR 7 2 ABE 7R16T210 Spring ABE 7P16F310E 0 850 Polarity distribution Screw ABE 7P16F312 0 850 No of Relay Type No and Polarity Reference Weight chan width of type of distribution nels mm relay contacts application kg Y 16 5 ABR 7S11 1N O Contact common ABE 7R16T111 0 600 a J per group of 4 channels JHB Contact common ABE 7R16M111 4 0
112. ctions continued TSX DEZ 08A4 08A5 pum O LLI _ o ab Cc lt O ep xe q9 0 2 O c 2 O 3 Y uN E O 5 gt E ay 2 H A H A ea o 2 Bik a 8 a ep s EIA H eA eA e A A O 5 a P DT c O 5D n n_ x2 Oo o o o O OOOO eloo eooo oo 5 Es a roA RAES 2S ACRORGRORGRORGRON lalo ele Lolo SEE Sos a2 o 235 Bala So 3 5 27 its gt 0 d a 221 xx aS gt gt gt losz xa 2 cate stja ia le ats See no g Te ONA Al e A ia L TIo 2S H F H Hl A ale E a ONO NONE E O E ROE ee RC iso solo la oo g elele late lolol ele ele le koe oee O O O e O74 Z N O 3 E i aia ajala a 3 O 3 x 5 OO CIA sl 8 o D 49 2 A 2 E F H o O ap lt r g 99 D Y LO 8 amp Sex L 2 BO 2 S TE 2 al Ale All ea E 5 e J3 S B a a E z o ole C C y O E Lalas NES 2 gt 18 LO 00 gt Y A 0 2 D 7 SA N O OR gt i T p rap 2 S A E E 5 ES E gt g PESO ES moe D LU U 10 a I 5 He Ds As 49 wz Connections continued TSX DSZ 04T22 Preactuators TSX DMZ 28AR Sensors N e o o la S anh e o lt ojojojojlojeleleololoclololololololol o I l lololojojlelo l jlelolojololo X 19 240 V 24 V Preactuators Specifications pages 43051 5 to 43051 8 Schneider Electric M
113. d state Relay 24 V 24 V 16 2 TSX 37 10 128DT1 16 2 TSX 37 10 128DTK1 6 E p TSX 37 10 128DR1 32 gp TSX 37 10 164DTK1 lt TTO 240V E gt gt R rra TSX 3710 025AR1 16 2 TSX 37 10 028DR1 Selection of modules to be inserted 3 slots available that is a maximum of 6 positions Type of module to be inserted Maximum number of modules 7 Format Connection 1 2 4 6 Stand Half Connect Term bik Discrete Inputs Outputs 8 inputs 12 inputs 32 inputs QA II TONI outputs fd 8 outputs 32 outputs 2 IS ID 16 inputs outputs L l 28 inputs outputs 2 MON o 64 inputs outputs OS Preventa safety module C ey MAIS AS i bus or I O extension 3 NN poo Analog VO Tor 8 inputs Po foo po 2 or 4 outputs O po Counter positioning 1 or 2 incremental encoder 1 absolute encoder channel POINTS SEE SERENA Communication Functions pages 43050 6 and 43050 7 43050 EN FM 4 Ethernet TCP IP or external Modem characteristics pages 43050 11 and 43050 12 External module Possible selection or insertion 1 With TSX RKZ 02 mini extension rack 2 This includes a standard format module to be inserted in the 1st slot of the PLC 3 The remote discrete I O extension modules and AS i bus modules are installed in position 4 which means that their use is mutually exclusive references pages 43050 13 and 43050 14 Dimensions mounting page 43050 15 Schneider Electric
114. dard m TSX SCP 111 PCMCIA card o Non isolated RS 232 D link This type of card can be used for direct point to point links or via Modem m TSX SCP 112 PCMCIA card 20 mA current loop link This type of card is used for a multidrop link 2 to 16 devices and requires a 24 V external power supply 1 TER port for TSX 37 05 08 10 PLC Other devices please consult our specialist catalogue TSX model 40 PLCs Nano PLCs TSX 17 20 micro PLCs PC compatible terminals Other connectable devices Characteristics page 43594 2 43594 FR_EN FM 4 Connection via processor Connection via the Connection via the Connection via the Uni Telway integrated port terminal port TSX SCG 1161 module terminal integrated ports or via TSX SCM 2106 of TSX 17 20 micro PLCs These give access to all communication module fitted with the devices in the X Way TSX P17 20 FC2 FD2 PL7 2 architecture micro software cartridge X Way drivers see page 43594 6 Designation Device references See page or catalogue Operator panel CCX 17 20 CCX 17 30 Page 43583 6 MMI terminals XBT H P E HM PM XBT F FC T XBT F Page 0372Q 2 Identification system XGS C5 Specialist catalogue Variable speed drives ATV 16 ATV 66 ATV 58 for asynchronous motors Specialist catalogue RTV 74 RTV 84 for d c motors Specialist catalogue MASAP servodrive MSP 62 Specialist catalogue Industrial terminals FT 2100 terminal Page 43586 4 Data pro
115. dicate blown fuse Presentation compatibility _ Dimensions schemes page 14029 2 page 14040 3 Schneider Electric 14025 EN fm 3 References 816467 A 3 OOOU0 SOQUGNE HONE ABE 7S16E2ee 816468 ABE 7R08S216 Presentation compatibility eS a ES E A TA Connection interfaces Telefast 2 pre wired system Connection sub bases with soldered relays and plug in terminal blocks Number No of Isolation Voltage Type Reference Weight of terminals PLC application of channels per channel V connection kg 16 2 Yes 24 Screw ABE 7S16E2B1 0 370 Spring ABE 7516E2B1E 0 370 48 Screw ABE 7S16E2E1 0 370 Spring ABE 7S16E2E1E 0 370 48 Screw ABE 7S16E2E0 0 386 Spring ABE 7S16E2E0E 0 386 110 Screw ABE 7S16E2F0 0397 Spring ABE 7S16E2F0E 0 397 230 Screw ABE 7S16E2M0 0 407 Sprin ABE 7S16E2M0E 0 407 No of Isolation Output Output Fault Type Reference Weight channels PLC voltage current detection of application V A signal 1 connection kg 8 No 24 0 5 Yes 2 Screw ABE 75S0882B0 0 252 Spring ABE 7S08S2B0E 0 252 2 Yes 2 Screw ABE 75S0882B1 0 448 Spring ABE 750852B1E 0 448 16 No 24 0 5 Yes 2 Screw ABE 751682B0 0 405 Spring ABE 7S16S52B0E 0 405 No Screw ABE 791681B2_ 0 400 Sprin ABE 7S16S1B2E 0 400 No of Relay No of Output Polarity Type Reference Weight channels width contacts current distribution of mm A application connection kg 8 5 1 N O 2 Contact common S
116. display panel power supply failure and full diagnostics of the safety system Electronic data acquisition units for full diagnostics of the safety system reading the state of the 8 pushbutton or limit switch inputs reading the enable input and the feedback loop reading the control signal of the 2 safety outputs monitoring the external power supply for the module O 0000BBBnwm0o This electronic data acquisition is designed so that the first failure will not adversely affect the safety function If the safety system uses more sensors it is possible to daisy chain several TSX DPZ 10D2A modules Schematic diagram To ensure correct operation of the safety function whatever the first failure the following must be used m At the inputs emergency stop pushbuttons or safety limit switches with dual contacts m At the outputs if relaying is required use relays with guided contacts m Module power supply use an F1 protection fuse see characteristics on page43307 4 TSX DPZ 10D2A KW XY XX siloj ayy gt S 4 0 Ne KeK y g y eee a 3 oun K x8 E t E o Bus Ba Ix 3 E co da Ix 2 O A n En K2 Ki 6 7 Control of the safety system 1 2 and 1 3 Safety outputs volt free 4 5 Feedback loop and run enable ESC additional enable conditions 14 15 Monitoring of module 24 V external power supply 14 12 12 10 10 8 8 6 8 read channels for the emergency stop pushbutton or limit switch contacts 7 9 9 1
117. dule supports the AS i M2 profile interrogates the device connected on the AS i bus in turn and stores the data state of sensors actuators operational status of devices in the PLC memory Communication management on the AS i bus is completely transparent with regard to the PLC application program An AS i power supply must be used for powering the various components on the AS i bus Ideally this PSU should be situated nearest to the stations with the largest current demands For further details please consult our specialist catalogue The TSX SAZ 10 AS i bus master is a half format module designed to slot into the basic configurations of TSX 37 10 21 22 Micro PLCs in position 4 one TSX SAZ 10 module per configuration 1 The front panel comprises 1 An opening with locating device for routing AS i bus ribbon or round cable to be connected to a terminal block inside the module 2 Four indicator lamps RUN the module is active ERR module fault or bus connection fault COM AS i bus communication is active AS i bus configuration error 3 A pushbutton to transfer the AS i bus display to the PLC front panel The Micro PLC centralised display block enables the display of the status of all the I O channels and the diagnostics for devices on the AS i bus present missing faulty not conforming to the configuration 1 Device number 2 Control pushbutton for accessing the various operating modes of the displ
118. e electrical on the other where an installation zone without devices is subject to high levels of interference or to extend the network for example between 2 buildings See pages 43597 4 to 43597 7 m The OZD FIG G3 fibre optic transceiver to guarantee availability of the installation by using the redundant ring type topology Operation remains normal even in the event of disconnection at a point on the fibre optic medium Wiring system TSX S rie 7 References page 43590 3 CCX 17 Fibre optique Third party Momentum Premium TSX FP FT 2100 TSX FPP 1 OZD FIF G3 Hirschmann fibre optic transceiver 2 TSX FP CAe00 shielded twisted pair trunk cable 150 Q diameter 8 mm for standard environment and inside buildings 3 TSX FP CG 0e0 tap off connecting cable for TSX FPP 10 20 PCMCIA module card for Micro Premium PLCs FT 2100 terminal and PC compatible 4 TSX FP ACC 3 4 T junction box It also has two 9 way female SUB D connectors for connecting any device which connects to the bus by a PCMCIA card 5 TSX FP ACC 12 9 way female SUB D connector for Fipway Fipio connection TSX FP ACC 2 for TSX 17 20 for example daisy chaining or tap link connection 6 TSX FP ACC 7 line terminator to be placed at each segment end TSX LES 65 terminal block for TSX Series 7 PLC which performs the address cod
119. e cut label ABE 7LOGF25 0 200 sheets 160 labels Description No of Characteristics Order in Unit Weight channels multiples of reference kg Kit for fixing on solid plate 10 ABE 7ACC01 0 008 Splitter sub base 16 as 2 x 8 channels ABE 7ACC02 0 075 Redundant output sub base 16 as 2 x 16 channels ABE 7ACC10 0 075 Redundant input sub base 16 as 2 x 16 channels 1 ABE 7ACC11 0 075 Removable continuity 10 mm wide 4 ABE 7ACC20 0 007 blocks 12 mm wide 4 ABE 7ACC21 0 010 Locating device for removable terminal block 100 ABE 7ACC30 0 100 Enclosure feedthrough 32 40 way 1 ABE 7ACC80 0 300 with industrial connector Plug in 40 way 32 For mounting on 1 ABE 7ACC81 0 370 male connector ABE 7ACC80 Enclosure feedthrough 16 19 way 1 ABE 7ACC82 0 150 with CNOMO M23 connector 1 x 20 way HE 10 8 and 12 19 way 1 ABE 7ACC83 0 150 connector PLC end Impedance adaptor Used with ABE 7ACC82 1 ABE 7ACC85 0 012 for Type 2 compatibility and ABE 7ACC83 IP 65 cable gland For 3 cables 1 ABE 7ACC84 0 300 Additional snap on 8 10 screw terminals 5 ABE 7BV10 0 030 terminal blocks A shunted terminals 10 spring terminals 5 ABE 7BV10E 0 030 16 20 screw terminals 5 ABE 7BV20 0 060 20 spring terminals 5 ABE 7BV20E 0 060 I O simulator 16 Display forcing 1 ABE 7TES160 0 350 sub base inhibition continuity Adhesive label holder For 6 characters 50 AR1 SB3 0 001 Fast blow fuses 0 125 A 10 ABE 7FU012 0 010 5 x
120. e probe or high level voltage and current ranges via external resistors supplied with the module see page 43053 5 for the various ranges The functions of the TSX AEZ 414 analogue input module are as follows m Selection of the input range of each channel m Scanning of input channels by multiplexing and acquisition of values m Analog digital conversion 16 bits of input signals m Monitoring of input value overshoots and sensor connections m Automatic linearization for Pt 100 and Ni 1000 temperature probes m Automatic linearization and internal or external cold junction compensation for thermocouple ranges m Converting input measurements to user format for display in directly readable units physical units or user range m Detection of sensor connection faults for thermocouple ranges The TSX ASZ 401 module provides 4 common point analog outputs 10 V or 0 10 V The TSX ASZ 200 module offers a choice between 10 V 0 20 mA and 4 20 mA ranges for both the common point outputs The various functions of the TSX ASZ 401 200 analog output modules are as follows m The acceptance of digital values corresponding to analog values obtained as output These values are calculated by the PLC task to which the channels are assigned MAST or FAST m Processing dialog faults with the PLC and setting the outputs to fallback state value O or maintained m Selection of the range for each output voltage or current module TSX ASZ
121. eb server launched See page 43312 6 1 The Modbus application service is outside X Way communication 2 The shared table service is only available on the Fipway network The COM distributed database service and the Shared Table service are mutually exclusive 43300 EN FM 2 E Modicon Schneider Electric E VA PE Application services Micro Automation Platform X WAY communication The Uni TE protocol is the industrial message handling system supported by the X Way communication architecture lt operates on the question answer or request confirmation principle A device which supports the Uni TE protocol can be a m Client this device initiates communication It asks a question reads transmits data writes or transmits an order Run Stop etc m Server this device executes the service requested by the client and sends a confirmation after execution The services provided depend on the type of device PLC numerical controller programming terminal supervision station etc Depending on its function each device can be Client and or Server Transparency terminal mn mu oO oO ma oO oO Q oO oO ie B i gt a O s iiini A Client device can access the system functions of a PLC Server even if there is no application program to read write language objects bits words etc upload download programs stop or start etc IT i i i
122. eceive the maximum of m TSX 37 05 10 2 TSX CTZ 1B modules in slots 3 and 4 m TSX 37 08 2 TSX CTZ 1B modules in slots 5 and 6 m TSX 37 21 22 4 TSX CTZ 1B modules in slots 3 4 5 and 6 and this within the limit of the number of channels generated by the Micro PLC see page 43054 2 The front panel of the TSX CTZ 1B half size positioning module 1 channel includes 1 A 9 pin SUB D connector for connecting the SSI absolute encoder 2 A high density 15 pin SUB D connector for connecting O 2 position value capture sensors O absolute encoder supply 3 A latch system for fixing the module in the slot Operation Functional synoptic of the positioning channel Configuration adjustment parameters Comparer 0 Comparer 1 Absolute lt 2 encoder input Comparer 2 Comparer 3 Modulo Capture qa Capture input 0 qm Capture input 1 Implementation of the TSX CTZ 1B requires the use of version gt 4 2 of the PL7 Micro Junior Pro software The Micro PLC receiving the module should be equipped with the operating system version gt 5 0 Specifications References Connections page 43313 3 page 43313 4 43313 5 Sealer 141 Le 10 LS Schneider Electric Specifications Module type Channel number Positioning input Voltage SSI absolute encoder Number of bits Frequenc Distance Parallel output encoder 7 Number of bits Number of inputs Nominal v
123. ects the AS i device reference from the various product families This selection determines the AS i profile and the parameters associated with the device m Third party AS i device The user can use PL7 Micro Junior software to manage a customised list of sensors actuators of different brands This list specifying the AS i profile and parameters is compiled to meet the needs of the user The configuration screen is also used to m Associate a symbol with each AS i input or output up to 32 characters m Define the fallback position of the actuators for all devices set to state O or maintained should the Micro Premium PLC stop Programming After configuration the I O connected on the AS i bus are processed by the application program in the same way as a PLC in rack I O using either the address eg M4 0116 2 input 2 of slave 16 of the AS i bus or the associated symbol eg Start_conveyor Schneider Electric Diagnostics specifications D fauts externes Un quipement en erreur D fauts internes Type of module Product certifications AS i profile Ambient air temperature Degree of protection Vibration resistance Shock resistance Number of connectable slaves Number of I O Transfer times 1 Execution time Average transfer time Maximum transfer time Bus connection Module power supply Display Diagnostics Schneider Electric Autres d fauts Erreur dans la configuration Micro
124. een 25 and 60 the use of fan modules increases the MBTF references Dimensions mounting pages 43050 13 and 43050 14 page 430 5 AS 43050 EN FM 7 RC Memory structure Functions pages 43050 6 and 43050 7 43050 EN FM 8 characteristics pages 43050 11 and 43050 12 Micro Automation Platform TSX 37 05 08 10 21 22 PLCs The memory structure of Micro PLCs consists of two distinct zones m An internal RAM memory designed to receive the application data program and constants of o 11 Kwords for TSX 37 05 08 PLCs o 14 Kwords for the TSX 37 10 PLC o 20 Kwords for TSX 37 21 22 PLCs m A Flash EPROM memory of o 12 Kwords for TSX 37 05 08 PLCs o 16 Kwords for TSX 37 10 21 22 PLCs designed to back up the application program 11 or 14 Kwords maximum and to back up 1024 MW internal words in the event of a battery failure or no battery For TSX 37 21 22 PLCs the internal RAM memory can be extended via a 32 Kword or 64 Kword PCMCIA memory card either RAM or Flash EPROM The same memory card incorporates the possibility of containing 128 K words designed to back up recipe or log files PCMCIA memory extension cards for TSX 37 21 22 PLCs These cards can be used to extend the PLC internal memory for storing the application program and constants Two types of memory card are available Battery backed RAM type memory card Used in particular during application program creation and debugging this card enables
125. eferences once one or more variables have been selected on the screen Version V4 0 of PL7 also enables character string type objects to be displayed Synoptics can be displayed on the full screen for ease of viewing Schneider Electric Functions continuea LD MAST MAIN OPERATE INC Data_12 Initialisation Table 10 L20 Trig_tempo Status_cyele Synehro_1 Cycle Raz Trig_sect_remp Trig_sect_vidan Forcer 0 Forcer 1 F Geforcer Affichage pL pee E Gest_prod_silo_a Gest_prod_silo_a Gest_prod_silo_a Gest_prod_silo_a Gest_prod_silo_a Gest_prod_silo_a F4 FS Etat graphe Actions graphe Pr positionnement Raz a Presel Count Done 1 Wal cou 1600000007 O 0000 wise EE a Fonction Compteur E Compteur 0 Le Comptage 3 Characteristics pages 43100 13 to 43100 15 Schneider Electric References page 43100 17 IM 240000 0000 0000 0000 00 IN IM OUT PUBLIC Micro Automation Platform PL7 Micro Junior Pro programming software Debugging tools PL7 Micro Junior Pro software offers a complete set of tools for debugging applications A tool palette provides direct access to the main functions m Setting stop points m Step by step program execution m Independent execution of the master MAST fast FAST and event triggered EVTi tasks
126. eider Electric 43596 EN FM 3 References 43606 EN FM 2 Micro automation platform Connecting cables for PCMCIA cards and TER AUX ports Micro Premium Device tobe Physical PLCs connected link TSX SCP 111 DTE terminal RS 232 D PCMCIA card 2 Protocol Length Reference Character mode 3m TSX SCP CD 1030 10m TSX SCP CD 1100 Weight 0 190 0 620 0 190 0 160 0 160 0 160 0 160 0 160 DCE terminal RS 232D Character mode 3m TSX SCP CC 1030 Modem etc 2 Uni Telway HN TSX SCP 114 TSXSCA50 RS 485 Character mode 3m TSX SCP CU 4030 PCMCIA card T junction box 2 wire Uni Telway 3 isolated J RS 422 485 Character mode 3m TSX SCP CM 4030 2 wire Modbus TSX SCA 62 RS 485 Uni Telway 3m TSX SCP CU 4530 2 channel 2 wire subscriber isolated socket 4 DTE terminal RS 422 485 Modbus 3m TSX SCP CX 4030 3 4 wire TSX SCP 112 Active or 20 mA Character mode 3m TSX SCP CX 2030 PCMCIA card passive current Uni Telway 1 terminal 3 loop Modbus TER AUX TSX P ACC 01 RS 485 ports 5 junction box TSXPACC RS 485 01 junction box for FTX 117 End of connecting cable fitted with 1 25 way male miniature connector 2 25 way male SUB D connector 3 Flying leads 1 Point to point supplied with 2 SUB D adapters TSX CTC 07 9 way male 25 way female and TSX CTC 08 9 way m
127. ence Guide English and French 2 For other Fipway network accessories and connection cables see pages 43597 6 and 43597 7 Schneider Electric py Modicon 7 43592 EN FM 3 Presentation Characteristics page 43599 3 43599 EN FM 2 Premium l let lle N te Connections page 43599 4 Ethernet TCP IP or Fipway Micro automation platform Modbus Plus network The Modbus Plus network is a high performance industrial local network which can respond to Client Server type extended architectures combining a high data rate 1 Mbps simple and economical transmission support and several message handling services 2 j Ie LJ Modbus Plus bridge ES Modbus HH Modbus device The main data exchange functions between all devices connected to the network are m The message exchange function according to the Modbus protocol m The global database function Shared Table service periodic controlled by the application a station with the token can send 32 words to a maximum of 63 other stations connected on the network 1 The Premium or Micro client communicates with the Quantum server on the Modbus Plus network 2 The Quantum client communicates with the Premium server on the Modbus Plus network via MSTR function blocks 3 A Premium or Micro client connected to the
128. er box 16 1 8 O Splitter box Splitter box Telefast connecting cables 161 160 16to2x8 to 2 x 8 1 8 O APP 2RH2 H4 APE 1R1628 ABE 7ACC02 TSX CDP ee3 ABF M32Hee0 2 81 8 O remain available To connect a second APP 1CH module or APP 2eee 8 E 8 S control splitter box use a additional TSX CDP est cable 3 8 O remain available on ABE 7ACCO2 To connect them a second AAP 2eee 16 1 8 O control splitter box use a additional TSX CDP ee3 cable Schneider Electric 43320 FR fm 3 Presentation Micro automation platform Use of Preventa safety modules Production workshops and technical building installations are subject to increasing requirements in terms of machine safety Y ZN N yb O Y S SS A good machine is a safe machine combining m Safety of personnel machine is not dangerous m Availability of the production tool machine operational at any time m Safety is achieved by m Simultaneously optimising safety and availability m Using basic principles redundancy self monitoring etc m Considering reliability failure determining the behavior of the machine in a specified position positive safety features m Ease of maintenance The machinery directive A machine manufacturer is required to conform to the machinery directive The machinery directive 89 392 EEC 91 36 EEC 93 44 EEC and 93 68 EEC is designed to ensure the free circulation of machinery and safety components in European Unio
129. er of counting positioning channels see page 43054 2 3 TSX CTZ ee counting positioning modules only in the Micro base 4 Default size can be extended but will have an adverse effect on the size of the application program Dimensions mounting 43050 14 page 43050 15 Schneider Electric References pP TSX 37 05 10 e28001 F F N gt Be A TSX 37 08 056 DR1 ye ke UD po A E YE TSX 37 22 e01 TSX RKZ 02 Description pages 43050 2 and 43050 5 Schneider Electric Functions pages 43050 6 and 43050 7 Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Power supply Integrated memories Integrated memory Reference Mass Discrete I O modules RAM Flash Type Connection 1 EPROM kg N 11 12 1 modules Via screw TSX 37 05 028DR1 2 370 100 240 V Kwords Kwords with 16 I terminal block data 24 supplied memory V 12 O relay 2 modules Via screw TSX 37 08 056DR1 2 720 with terminal block 161 24 V supplied 12 O relay Power supply Integrated memories Integrated memory Reference Discrete I O modules RAM Flash Type Connection 7 kg EPROM 24 V 14 15 16 I 24V Via screw TSX 3710 128DT1 1 870 Kwords Kwords 12 Solid state terminalblock data O05A supplied memory 161 24 V Via screw TSX 3710 128DR1 1 900 12 Orelay terminal block supplied 161 24V ViaHE 10 TSX 3710 128DTK1 1 740 12 Solid state type O05A connector 321 24V ViaHE10 TSX 3710 164DTK1 1 820 32 S
130. er tasks and they are therefore suitable for processing operations requiring very short response times to the occurrence of an event They can be programmed in Ladder Structured Text or Instruction List language Number of EVTi control events m Micro PLCs 8 events with TSX 37 10 and 16 events with TSX 37 21 22 m Premium PLCs 32 events with TSX 57 10 and 64 events with TSX 57 20 30 40 and PCX 57 20 30 Micro TSX 37 21 22 and Premium PLCs have 2 priority levels EVTO event has priority over other EVTi events Characteristics References pages 43100 13 to 43100 15 page 43100 17 43100 EN FM 6 Schneider Electric Ladder language structured text language OPERATE es KA ed T Ea as Jed ord EA ST MAST SR9 Test Pr selection Effectu gt INIT D IF 12 0 1 THEN ELSE QW2 0 X1 FALSE END_IF L130 Test CAPTURE Voie 0 gt INIT D IF 12 0 2 THEN 042 0 X2 TRUE Z M6 FALSE ELSE QW2 0 X2 FALSE F END_I L140 Test CAPTURE Effectu e Voie 1 gt INIT Donn es CAPTURE IF I2 1 2 THEN 7 042 1 X2 TRUE Schneider Electric Micro Automation Platform PL7 Micro Junior Pro programming software Program structure section SR or event triggered task Programs written in Ladder language consist of a series of rungs which are executed sequentially by the PLC Each rung may be m Identified by a label m Completed by a
131. erminal 3 TER available for programming and adjustment terminal Schneider Electric E Modicon 0464Q EN FM 3 Communication architecture Level 3 Level 2 Level 1 43609 EN fm 2 Micro automation platform Ethernet Ethernet TCP IP Uni TE Modbus Micro Sih 5 TSX ETZ Q ii E ol lire lare e TSX ETZ Modbus bus Magelis Monitor Pro Ethernet TCP IP Uni TE Modbus Premium AS i bus XAL control station Intelligent sensors Schneider Electric Digital HP PC compatible Ethernet TCP IP Modbus Quantum Web server Quantum Premium Web server Ethernet Magelis TXBT F I O Scanning ATV 58 a Premium Premium Premium Sensors Quantum Motor starter XAL control Intelligent XBL keypad station sensors Thin Client compatible PC PC having only Windows and an Internet browser see page 43601 6 Motor starter Schneider Electric AAC 43609 EN fm 3 Way ano the OS Mode Micro Automation Platform X WAY communication The International Standard Organization ISO has created a reference model for communication structures divided into seven essential functions Entitled OSI Open Systems Intercommunication it enables open systems to be connected together thus ensuring that products will operate together The communication architecture of Micro
132. ervice Ethernet TCP IP Ethway 7 Fipway Fipio Uni Telway Telegram 16 bytes 3 Note The telegram service remains local to a network lt can be inhibited 1 Ethway is not available on Micro PLC 2 Size limited to 128 bytes on Micro Premium PLC terminal port TSX PMX model 40 PLCs and to 32 bytes on TSX 17 20 and TSX 47 20 25 3 Telegram service not available on the Micro and TSX 17 20 W Modicon 43300 EN FM 5 E TIA y Presentation N N ly 43312 EN FM 2 Micro automation platform Ethernet network and TCP IP Modem serial link Micro platforms connect to the Ethernet TCP IP network via 2 external and autonomous TSX ETZ 410 510 modules These modules are also used to link to an external modem Ethernet TCP IP TSX ETZ 410 module The TSX ETZ 410 module includes m A Modbus Uni TE TCP IP communication profile on Ethernet 10 100 Mbits s or TCP IP via RS232 serial link connected to an external 56K bits s modem m The integrated Web server function The integrated Web server provides access to o the module configuration o the PLC diagnostics system function Rack Viewer O the communication diagnostics function O the access function to the PLC data and variables Data Editor O and accepts the scanned input output function the TSX ETZ 410 can be scanned by a device which supports the exchange of I O Scanning input outputs Ethernet TCP IP TSX ETZ 510 module The Ethernet TSX ETZ 510
133. events 11 Kword internal protected RAM memory 14 Kword internal protected RAM y 100 240 V integrated 24 V sensor power supply y 100 240 V integrated 24V 16 inputs 24 V 2 x 16 inputs 24 V 16 inputs 115 V or 12 relay ouputs 12 relay ouputs 24 V depend on model 12 relay ouputs 24 V depending on model Via screw terminal block 43050 13 0460Q EN FM 2 Schneider Electric For control systems which require a signifiant For control systems which require low cost amount of processing program and data and or analogue l O and fast counting functions communication I O module 3 non equipped with discrete I O module 2 184 248 160 248 I O on AS i bus total with in rack discrete I O input 24 V relay outputs Integrated seconds minutes hour day month year 8 inputs 8 bits 0 10 V 0 20 mA 4 20 mA 1 ouput 8 bits 0 10 V 4 half format modules each providing 3 inputs and 1 ouput inputs 12 bits 0 10 V 10 V 0 20 mA 4 20 mA output 11 bits 0 10 V 10 V 0 20 mA 4 20 mA control with MMI on CCX 17 operator panel control and adjustment of 9 loops maximum 2 x 500 Hz channels using discrete inputs and 2 integrated 10 kHz channels 4 half format modules Uni Telway master slave 1 fixed station auxiliary port and 1 terminal port RS 485 protocole Uni Telway master slave Modbus character string protocol master slave or character string protocol 1 PCMCIA
134. f a flowchart analysis and is organized into statements Each statement consists of a label 1000 labels max comments 256 characters max and instructions There are four methods for controlling statements m Conditional action IF m Conditional iterative action WHILE action repeated while a condition is true m Conditional iterative action REPEAT action repeated until a condition is true m Repetitive action FOR action repeated a certain number of times Program editor Structured Text language The editor enables statements to be entered one after another The editor provides help with entering m Modifications insertion etc m Cut copy paste Objects can be entered and displayed in either symbol or address format Different colors are used for the objects language key words and program comments to make it easier to read 43100 EN FM 7 Grafcet language Instruction List language EA GRAFCET MAST Chart 4 m lalala Al Sis le el sl PL Junior T57_AD2 L MWLO 2MY10 1 validation Vidange LS 412 12 ST 201 7 marche Avant Moteur L2 ID 12 15 AND 2M132 ST 201 19 LD M140 MW11 MW114 1 LD M12 Characteristics References pages 43100 13 to 43100 15 page 43100 17 43100 EN FM 8 Micro Automation Platform PL7 Micro Junior Pro programming software Grafcet language is used to describe
135. fferent possibilities for extending the I O m Either with the TSX STZ 10 remote discrete I O extension module The discrete I O of 4 Nano PLCs can be used at a distance of up to 200m one of which can be a Nano extension PLC These Nano PLCs can be used as remote discrete I O or local slave PLCs For further details see pages 40056 2 40056 3 m The AS i sensor actuator bus Micro PLCs are connected to the AS i bus via an AS i master module In this case the PLC becomes the master station on the bus and manages a maximum of 248 I O over a distance of up to 100 m 200 m with a repeater For further details see pages 43610 2 to 43613 3 Analogue I O and process control Micro PLCs offer several ways of performing analogue processing m For data input or commands which do not need a high resolution level using I O integrated in TSX 37 22 PLCs m For precise measurement and commands using TSX AEZ ASZ AMZ eee half format analogue I O modules m To locate analog I O remotely via the TSX STZ 10 rackmaster module with TSX 37 10 21 22 PLCs The latter enables the use of three TSX AMN 400e analog extensions each equipped with 3 analogue inputs and one analog output For further details see pages 40055 2 and 40055 3 43053 2 to 43053 7 Micro PLCs have as standard process control functions which can be accessed by the user via the PL7 Micro PL7 Junior or PL7 Pro programming software For further details see pages 43531 2 and 43531 3
136. ge of 32 broadcast words Peer to peer Read write services amount of requests 100 registers per transaction dialogue Peer Cop Cyclical exchange service on Premium only 500 words per station broadcast or point to point Connections References page 43599 4 page 43599 5 43599 EN FM 3 Schneider Electric Connections Characteristics References page 43599 3 page 43599 5 43599 EN FM 4 Micro automation platform Modbus Plus network TSX MBP 100 Modbus Plus PCMCIA card for type III processor slot on Micro or Premium platforms 170 PNT 110 20 communication module for Momentum I O base unit 490 NAA 271 Oe trunk cable shielded twisted pair with shielding drain flying leads In lengths of 30 150 300 450 or 1500 m 170 MCI 020 021 ee drop cable equipped at each end with an RJ 45 connector interface baseT In lengths of 0 25 0 75 3 or 10 m 990 NAD 230 00 IP 20 local site tap provides a tap link from the trunk cable for connecting 1 device connection of conductors requires wiring tool 043 509 383 990 NAD 230 10 IP 65 zamac local site tap provides a tap link from the trunk cable for connecting 1 device screw terminal connection lt also has an RJ 45 connector for connecting a programming and maintenance terminal 170 XTS 020 00 IP 20 tee provides a tap link from the Modbus Plus cable cable with connectors at each end of an RJ 45 connector It has a 9 way SUB D con
137. graphical site team only Device gt with 8 user stations for a geographical site only Client server network architecture server device Use of the PL7 Pro Reference Weight kg TLX CD PL7P P 42M TLX CD PL7P P 42M z TLX OT PL7P P42M TLX OS PL7P P42M TLX S PL7P P42M package Pro Servi 1 via client network stations and using the access 1 station update 3 station update TLX RCD PL7P P 42M TLX RCD3 PL7P P 42M Software updates for previous version of PL7 Pro Software upgrade Micro Premium PCX Premium TLX UCD PL7P P 42M Micro Premium 1 station upgrade packages from previous PCX Premium 3 station upgrade TLX UCD3 PL7P P 42M version of PL7 Junior Separated elements Description Description Reference Weight in kg X Way drivers package CD Rom including the X Way drivers package in Windows TSX DRV 12M for compatible PC Uni Telway Fipway Fipio Ethway XIP ISAway in DOS and Windows Uni Telway for TSX SCP 114 card Terminal port in OS 2 PL7 setup manuals Hard copy including PL7 reference manuals functions TLX DOC PL7 42F 3 410 package communication converters and diagnostics in English 1 Software package including an annual software subscription current year after return of the registration certificate Characteristics References pages 43100 13 to 43100 15 page 43100 17 Schneider Electric 43100 EN FM 17 Presentation Micro automation platform setup PL7 SMC applic
138. have an integrated Web server On a Micro PLC level the functions of the Web server allow o configuration O diagnostics o access to variables O graphic editing o display of predefined Web pages and O use of a Web page configuration tool This server is a PLC real time data server All Micro PLC CPU data which support one of these modules are presented in the form of standard HTML web pages and can also be accessed by all standard browsers capable of embedded Java or by FactoryCast software supplied on CD ROM with each Ethernet module All functions from the Web server do not require any configuration or programming either on the level of the Premium PLC or on the level of the compatible PC which supports the Internet browser Furthermore this module can be used in an existing configuration without any modification to the current program 43312 EN FM 6 Schneider Electric Functions continued Micro automation platform Ethernet network and TCP IP Modem serial link e Ps ETS Configuration function O A N O a e rE The configuration function for the module is a predefined function It allows ee Elle ales m Altering the user name and password for access to the secure page O E Configuration of the TCP IP parameters ATA m Configuration of the Uni Telway parameters m Automatic re configuration m Configuration of the SNMP parameters m The module reset Baud Rate 57400 y Parity None 7
139. he application program at the start of the scan for reading and at the end of the scan for writing The user program consists simply of assigning or reading these common words NW As the COM service has a field of dedicated and preconfigured words there is absolutely no risk of conflict of data between or within PLCs This service exchanges a table of internal words MW divided into as many zones as there are Micro Premium PLCs which comprise the Fipway network The exchange principle is based on the broadcasting by each PLC of a word memory zone broadcast zone to other PLCs on the network Each network station is allocated an exchange table comprising MW internal words The maximum characteristics of the exchange table are 128 MW internal words for 32 PLCs sharing the Shared Table service on the network Broadcast zone assigned to each PLC variable from 1 to 32 MW internal words the size of the broadcast zone assigned to PLC n should be the same length in all the PLCs on the network sharing this service Fipway Ethway EU He qe Om Mil Om ail CC a Shared Table MW maximum 128 words The exchange table in each PLC is updated automatically and independently of the program scan cycle The user program consists of simply assigning or reading words MW in the broadcast zone The user must take care when configuring and assigning broadcast zones not to create memory conflicts between or within PLCs Availa
140. hese architectures the Nano I O are considered by the PL7 1 output Micro Junior Pro programming software to be objects integrated in the Micro PLC Nano base 24 I O Configuration One to four Nano PLC bases with 10 16 or 24 I O i e a maximum of 96 discrete I O Length 200 m Analogue Nano extension 3 inputs 1 output Local slave PLC configuration Apart from the advantages already mentioned this type of configuration enables each sub assembly or process block to be handled independently and only the data necessary for the synchronization and control of sub assemblies to be handled at the highest level This structure also ensures better availability in the event of sub assembly failure or repair This configuration enables application data to be exchanged between a Micro PLC and up to three Nano PLCs This data set at two read words and two write words per Nano is Micro master exchanged transparently with the Micro master Slave Nano PLCs are programmed and set up in PL7 language using an FTX 117 dedicated terminal or PL7 07 software E N lt D Nano base Nano base Nano base slave slave slave Mixed configuration J Analogue Nano extension 3 inputs 1 output It is possible to combine both types of configuration on one link in which case the maximum number of Nano PLCs is limited to 4 master Nano base Nano base
141. his case certain PL7 program functions can be executed following commands sent by an OLE client application This instance of the program then no longer reacts to commands from the operator keyboard Server mode can be launched in offline mode COM if both programs are on the same machine or in remote mode DCOM if the programs are installed on different machines The commands available are as follows m Manage an execution context open close an application modification of the address and driver of the connected PLC PLC status m Control the PLC connection disconnection send a RUN STOP INIT command program uploading downloading m Read data application or symbol export only in source format read symbol comment associated with an address read application identity Schneider Electric Installation continuea 4 PL7 Junior SECHAGE Fichier Edition Services Yue Application AP Debug Option ajja el ojal Sale ssl Eli een Configuration 1 E Configuration mat rielle Configuration logicielle i o Configuration des objets Grafcet en Programme i a g T che Mast i EY Sections i E 3 cycle_normal Qee E chan E inf A Post DOS so pod ha E Sri i im faq Ev nements Sz il 03 Types DFB i ee E53 Essai tS Variables ZH Objets m moire Z5 Objets syst me KK Constantes i Objets grafcet fa FB pr d finis o E9 ENS i DEE Instances DFB Y Tables d animat
142. hneider Electric ECZ 43051 EN FM 9 References continued ABE 7TES160 TSX BLZ L01 Specifications pages 43051 5 to 43051 8 43051 EN FM 10 Description 20 wire pre formed cable 500 mA max Connecting cables 100 mA max Connecting cables 500 mA max Description Telefast 2 Micro automation platform Discrete l O modules Constitution Use 1 HE 10 type connector moulded 1 end free with wires identified 2 HE 10 type connectors for Telefast 2 system 2 HE 10 type connectors moulded for Telefast 2 Tego Dial Tego Power systems 16 channel simulator sub base for discrete inputs outputs Description Screw terminal blocks supplied with I O modules with screw terminal block connection Connections pages 43051 11 to 43051 13 Cross section Length 0 324 mm2 3m 10m 0 08 mm2 1m am 0 324 mm2 0 5m 2m 5m Use Has 2 HE 10 type connectors which enable it to be inserted between the PLC I O module and the ABE 7H P R S Telefast 2 I O sub base Used for display forcing inhibition or continuity of discrete I O Use For half format modules For standard format modules Reference TSX CDP 301 TSX CDP 501 TSX CDP 1001 TSX CDP 102 TSX CDP 202 TSX CDP 302 TSX CDP 053 TSX CDP 103 TSX CDP 203 TSX CDP 303 TSX CDP 503 Reference ABE 7TES160 Reference TSX BLZ H01 TSX BLZ L01
143. ication m Processor coprocessor m Tasks m Application specific I O modules m Memory By clicking on an unconfigured position the display of a dialog box shows the available I O modules classed according to family Once the various modules are positioned selecting them accesses parameter entry for each module Software configuration The configuration editor can also be used to set the software parameters of the application choice of the number of constants number of internal words and the number of each type of function block The configuration editor provides access to parameter entry for the function blocks The copy paste function for these parameters is available from version gt V4 0 of the PL7 software onwards Configuration of Grafcet objects When programming in Grafcet language the configuration editor can define Grafcet objects steps macro steps etc and execution parameters number of steps and active transitions A number of tools are provided as standard for setting up the various applications discrete I O analog I O counting motion control 7 man machine interface MMI communication weighing 7 Warm Standby redundancy 2 The parameter screens for the application specific functions are accessed from the I O configuration screen by clicking on the position in which the module has been defined The screens enable the main operating characteristics of the chosen application to be defi
144. icro automation platform Discrete I O modules TSX DSZ 08R5 Outputs Preactuators Ao PE Aa Pale ME MAP PE ME 1 ME o PA al nv 19 240 V 24 V TSX DMZ 64DTK Sensors Inputs al Outputs SoS e oom 6 0 B 19 3 20 4 Boe E Rare Soo 27 oo 24 8 12 T a ae E T 28 12 OOO ie i a o MN 31 15 r a 24V 19 Channels B1 BO O NANA 16 0 o BO ig 00 y L 3 nn p iO 2 5 10 gt TH 26 nn p 1j z7 99 54 8 nn p ra 25 9 a Ne 26 10 al 27 M7 wt 28 12 ed ye ee r Outputs a os f 1 o ee Preactuators Outputs References pages 43051 9 and 43051 10 E Modicon Preactuators Input 1y power supply Output 24 V power supply TSX DMZ 16DTK Sensors Inputs Sensors Outputs 1 10 A fast blow fuse 2 Fast blow fuses rated according to the load 3 0 5 A fast blow fuse 4 6 3 A fast blow fuse 5 2 A fast blow fuse 20 wire preformed cable TSX DEZ DSZ DMZ eeeeK Correspondence between HE 10 connector pin and colour of wire 1 white 11 grey pink 2 brown 12 red blue 3 green 13 white green 4 yellow 14 brown green 5 grey 15 white yellow 6 pink 16 yellow brown 7 blue 17 white grey 8 red 18 grey brown 9 black 19 white pink 10 purple 20 pink brown 43051 EN FM 13 Connection interfaces Telefast 2 pre wired system Discrete input and or output sub bases ee gt eee gt 1 to3
145. ies are multiplied by three All documentation reference software setup manuals reference TLX DOC PL7 42F should be ordered separately 1 Minimum configuration Pentium 133 MHz processor 48 Mb of RAM memory with Windows 95 98 or 64 Mb with Windows NT 50 Mb available on hard disk 25 Mb for software and 25 Mb for temporary directories CD ROM drive for installation of the PL7 program VGA screen or above 2 Typical recommended configuration Pentium processor 266 MHz 128 Mb of RAM memory CD ROM drive for installation of the PL7 program VGA screen or above Characteristics References pages 43100 13 to 43100 15 page 43100 17 43100 EN FM 16 Schneider Electric References continuea Micro Automation Platform PL7 Micro Junior Pro programming software PL7 Micro software packages PL7 Micro enables programming in Instruction List Ladder Structured text and Grafcet language It can also be used to set up application specific functions and undertake maintenance and diagnostics of the developed applications lt includes the PL7 2 application converter Description PL7 Micro software packages Software updates for previous version of PL7 Micro For PLC Micro Micro Type 1 station device 3 station device 1 station update 3 station update PL7 Junior development software packages Reference Weight kg TLX CD PL7M P 42M TLX CD PL7M P 42M TLX RCD PL7M P 42M TLX RCD3 PL7M P 42M PL7 Ju
146. il 122 x 229 x 248 35 x 95 x 60 499 NTW 000 ee 499 NTC 000 ee Shielded twisted pair cables Crossed shielded twisted pair cables 2 5 12 40 or 80 5 15 40 or 80 Type RJ45 at each end UL CSA 22 1 and NFPA 70 approval indicated by the letter U at the end of the reference for example 490 NTW 000 40U Category 5 of the ElA TIA 568 international wiring standard class D of IEC 11801 EN50173 Fireproof LSZH product flame retarded according to NFC32 070 1 C2 and IEC 322 1 A 490 NOC 000 05 490 NOT 000 05 490 NOR 000 05 ES Standard glass fibre optic 5 NN MT RJ SC duplex MT RJ ST MT RJ MT RJ No radiation along the cable length Schneider Electric References 2 F F 13 499 NEH 004 10 499 NOH 005 10 1 t la 499 NEH 041 00 a 4 LES 499 NES 071 00 US e 174 CEV 300 10 Characteristics pages 48190 3 to 48190 6 Schneider Electric Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface Description Type of Ethernet network TF hubs 10 Mbps 100 Mbps TF switches 10 100 Mbps TF transceivers 10 Mbps 100 Mbps Description Type of interconnection Modbus Plus Ethernet Modbus single double pair Modbus Ethernet TF bridges Preformed at each end Description Shielded twisted RJ45 type connector pair cables Crossed shielded RJ45 connector twisted pair cables Fibre optic cables MT RJ SC du
147. in a simple and graphic manner the sequential part of control systems It corresponds to the SFC sequential function chart language described in standard IEC 1131 3 Structure of the section in the master task Grafcet SFC language is only used in one section of the master task This is structured in three processing operations see page 43100 6 Programs written in Grafcet SFC language consist of m Macro steps 7 which are the only representation of a set of steps and a transition m Steps with which the actions to be executed are associated m Transitions with which the conditions are associated transition conditions m Directed links connecting the steps and transitions See characteristics page 43100 13 The actions continual pulsed on activation or deactivation and transition conditions can be programmed in the desired language Ladder Structured Text or Instruction List Program editor Grafcet SFC language The editor offers 8 pages each consisting of 11 columns and 14 lines giving 154 cells per page A palette of graphic objects is used for direct access to each graphic symbol macro steps steps transitions sequence selection simultaneous activation deactivation and connectors Programming of the transition conditions and actions is performed simply by clicking on the required chart element On a Grafcet page comments of up to 64 characters can be entered in any cell Functions which assist entry cut copy
148. inal Current 1 Nominal reference voltage voltage mm V A V kg 5 Output 24 2 24 ABS 7SC1B 0 010 10 Output 24 0 5 5 48 ABS 7SC2E 0 016 y 24 240 ABS 7SA2M 0 016 12 Input ae 5 TTL 24 ABS 7EC3AL 0 014 24 Type2 24 ABS 7EC3B2 0 014 48 Type2 24 ABS 7EC3E2 0 014 ay 50 Hz 48 24 ABS 7EA3E5 0 014 ay 60 Hz 110 130 24 ABS 7EA3F5 0 014 230 240 24 ABS 7EA3M5 0 014 Output 24 2 24 ABS 7SC3BA 0 016 Self protected 1 5 5 48 ABS 7SC3E 0 016 1 5 ny 24 240 ABS 7SA3M 0 016 Relay Control Output No of Order in Unit Weight width voltage current 1 contacts multiples of reference mm V A Ith kg 5 24 5 1 N O 4 ABR 7S11 0 005 10 24 5 1 N O 4 ABR 7S21 0 008 1 C O 4 ABR 7S23 0 008 12 24 10 1 C O 4 ABR 7S33 0 017 8 2 C O 4 ABR 7S37 0 017 48 8 1 C O 4 ABR 7S33E 0 017 Description Reference Weight GD Extractor for 5 mm miniature relays ABE 7ACC12 0 010 1 See characterics table for specifications of relays in the sub bases Dimensions schemes page 14029 2 page 14040 3 Schneider Electric WW Telemecanique 14025 E N References ABF C08Reee Dimensions page 14040 3 14040 EN fm 2 Micro automation platform Telefast 2 pre wired system Accessories for connection sub bases Description Operating system Reference Weight k Software for Under Windows ABE 7LOGV10 0 350 client label marking version 3 1 or 95 Pack of 25 pr
149. ing Schneider Electric Presentation continued characteristics references Performance Type of bus network Structure Type Topology 1 Access method Transmission Mode Data rate Medium 2 7 Inter repeater distance No of connection points 1 No of devices Configuration No of segments 1 Length 7 Tap links 7 Services Micro automation platform Fipio and Fipway on fibre optic cables Fipio bus operating mode and performance on fibre optics After configuration in Fipio mode the processor scans the various application devices according to the software configuration m Image variables of the input values and of the output command values of a configured device are scanned as quickly as possible on the bus whilst respecting the relationship existing between periods of different tasks which use these devices m Appearance or disappearance of a configured device is detected on the bus within a maximum time of 200 ms m Exchanges occur at the rate defined by the programmer from 10 to 20 Uni TE messages per second The network cycle time is double that of the electrical bus when OZD FIP G3 transceivers are used Fipway bus operating mode and performance on fibre optics The operating principle is identical to that on an electrical network in that the number of stations is limited to 32 and the transmission time is as follows m For the Common words and Shared Table services updating of the ent
150. instructions E Delete insert replace character extraction DELETE INSERT REPLACE MID LEFT m Comparison find length EQUAL_STR FIND LEN Binary conversion instructions m BCD 16 bits lt gt 16 bit integers BCD_TO_INT INT_TO_ BCD m BCD 32 bits lt gt 16 bit integers DBCD_TO_INT INT_TO_DBCD E BCD 32 bits lt gt 32 bit integers DBCD_TO_DINT DINT_TO_DBCD E Gray gt 16 bit integer GRAY_TO_INT 1 1st value for the Micro PLC 2nd value for the Premium PLC 2 Operation on double word replace W with D 3 Operation on floating tables replace W with R Schneider Electric Characteristics continuea References page 43100 17 Schneider Electric Micro Automation Platform PL7 Micro Junior Pro programming software Functions and instructions continued Logarithmic and exponential instructions m Base 10 natural logarithms LOG LN m Exponential nature real by integer EXP EXPT ORPHEE instructions 7 E Shift left on word or double word with retrieval of shifted bits WSHL_RBIT DSHL_RBIT E Shift right on word or double word with filling with Os and retrieval of shifted bits WSHRZ_C DSHRZ_C E Shift right on word or double word with signal extension and retrieval of shifted bits WSHR_RBIT DSHR_RBIT m Up Down counting with overrun signal SCOUNT Addressable objects 2 Bit objects l Qx i I O module inputs outputs Mi internal bits 256 on Micro TSX 37 3692 on T
151. ion t Dossier de Page de garde a Informations g n rales Y Ecran d exploitation 7 Pr t LOCAL 3 Havigateur Application Al x fa da DJS Eg Vue Structurelle E E MACHINE_DOSAGE Ej nnan Sequentielle 1 Es Proc d Post sess of Remplir Remplissage e E T che Fast EX Informations utilisateur Maintenance E Options Utilisateur s Dupin Ajouter Dutoit D Supprimer Exporter Importer iste des privil ges de Operate Privil ges ep privil ge autori Cr er une nouvelle application Duvrir une application existante Enregistrer une application Importer une application D marrer arr ter et initialiser automate Characteristics References pages 43100 13 to 43100 15 page 43100 17 Schneider Electric Micro Automation Platform PL7 Micro Junior Pro programming software Application browser conventional view Access to all programming and debug tools is gained via the application browser This gives a global view of the program and enables all the application components to be accessed quickly via shortcut menus 1 2 Configuration editor Program editor DFB user function blocks editor Variables editor Animation tables editor Documentation editor Runtime screens editor Concept of sections and Grafcet enhancement In order to make programs more comprehensible the FAST and MAST tasks are split into sections
152. ion Platform Integrated analog channels and analog I O modules Analog I O modules do not require an external power supply energy is provided via the Micro PLC power supply For maximum reliability these modules do not contain any electromechanical components there are no multiplexing relays no configuration switches and no adjustment potentiometers These modules only contain solid state components and are configured using PL7 Micro or PL7 Junior or PL7 Pro software These modules TSX AEZ 801 and TSX AEZ 802 are analog input modules with 8 high level multirange voltage or current channels For each input they offer a choice between 10 V or 0 10 V TSX AEZ 801 and 0 20 mA or 4 20 mA TSX AEZ 802 ranges according to the selection made in the configuration The various functions of the TSX AEZ 801 802 analog input modules are as follows m Scanning of input channels used by solid state multiplexing normal or fast and acquisition of values m Analog digital conversion 11 bits sign or 12 bits of input signals The processing performed by the PLC processor in addition to these functions m Monitoring of input overshoots m Filtering measurements m Converting input measurements to user format for display in directly readable units The TSX AEZ 414 module is an analog input module with 4 different channels Depending on the selection made in configuration and for each channel it provides the thermocouple temperatur
153. ion conversion requirements using PL7 Junior and PL7 Pro setup software lt comprises e Aset of 3 1 2 disks e A multilingual user manual English French and Spanish Application converter software for SMC PLCs Description Function Target PLC Reference Weight extension kg PL7 SMC Facilitates conversion of PL7 Junior Pro TLX LC SMC PL7 40M 0 560 application SMC 200 500 and Micro Premium converter SMC 25 35 50 600 software applications to PL7 applications Converts sequential information into Ladder language and data 43103 EN FM 3 Schneider Electric Presentation setup A Class01 BG PL7 SDKC 3 0 Famille ouverte Outils Famille Nom Outils Etat Non g n r e Date de sauvegarde 21 01 1998 10 57 Date de g n ration Code fi FRDES Code E Taille de la pile en octets 64 Taille de l EF g n r en octets 286 Version 225 Code 271 F Indice compatibilit Info textuelles fi Version 3 25 Type Automate Cible Version gt 3 0 avec coprocesseur math matique Commentaire o OUBLE ff PL7 SDKC 1 5 Famille ouverte Programme Famille Edition Services Aide References page 43101 3 43101 EN FM 2 do not modify the generated function prototype The main EF Function must be the first in this finclude lt Cstsyst h gt finclude lt Foteyst h gt include lt C ASAWTEMPSSDECS C include lt C ASAWTEMPSSDK
154. ire database is carried out every 40 ms maximum m For Uni TE message handling the network characteristics enable transmission of 230 messages maximum of 128 bytes per second ree TC Open industrial support conforming to Fip standard In redundant ring or in a line with simple redundant link Producer consumer principle Management by a fixed arbitrator Multimode 860 nanometres 1 Mbps Fibre optic 50 125 17 dBm or 62 5 125 15 dBm 2500 m for 50 125 and 2800 m for 62 5 125 Producer consumer principle Management by an automatically elected arbitrator 20 fibre optic transceivers OZD FIP G3 type maximum 2 Fipio devices can be connected to the same fibre 16 stations can be connected to the same fibre optic optic transceiver transceiver but the maximum number of stations is 32 The loop or fibre optic line is similar to a non cascadable segment Maximum circumference of the ring or length of the line 20 km From OZD FIP G3 fibre optic transceiver the maximum length of the electrical tap link is 100 m Same as page 43597 2 apart from the Telegram service which is not available with OZD FIP G3 fibre optic transceiver 1 Characteristics specific to use of fibre optics 2 Devices connected on electrical tap links are compatible with the WorldFip physical layer TSX FPP 20 10 Schneider Electric Description No of trans Connectable devices Reference Weight ceivers per Fipio bus Fipway bus or network ne
155. ith 1 8 way female mini DIN connector 4 25 way male SUB D connector 2 9 way female SUB D connector 5 Flying leads 3 9 way male SUB D connector 5 15 way male SUB D connector 1 Point to point supplied with 1 SUB D adapter TSX CTC 07 9 way male 25 way female 2 TSX PCU 1031 cable to be used with terminal equipped with PL7 V 4 0 software reference TLX eee PL7 e P 40M For PL7 V lt 4 0 software use TSX PCU 1030 cable 3 Point to point supplied with 2 SUB D adapters TSX CTC 07 9 way male 25 way female and TSX CTC 08 9 way male 25 way male 4 Point to point supplied with 1 SUB D adapter TSX CTC 09 9 way female 25 way male Schneider Electric AAA 43606 EN FM 3 Micro automation platform Programming software Micro Micro Premium Yes Yes Yes Yes Yesi Yes Yes with macro steps for Premium Yes Yes Use for Premium Creation use for Premium No No Yes Premium No No Yes Premium No No Yes Premium Creation use Development debugging of applications with A broswer accessing all the application components Dedicated editors Two types of application structure single task or multitask Master and fast tasks divided into sections Possibility of selecting the desired language in each section Debugging simplified by automatic creation of animation tables For Premium m Use of Grafcet macro steps m Application split into function modules m Use of function blocks DFBs reusable in any application in
156. ium Micro ATE Mth Gl Ei li BE i UL Elis Etre References page 43100 17 Characteristics pages 43100 13 to 43100 15 43100 EN FM 2 Micro Automation Platform PL7 Micro Junior Pro programming software PL7 Micro Junior Pro software is designed for Windows 95 Windows 98 Windows NT 4 0 and Windows 2000 Professional operating systems and therefore benefits from all the features associated with these operating systems User friendly software More user friendly and productive due to m Shortcut menus on the right mouse button for quick access to the services available for the object selected m Contextual help direct access to the help facility corresponding to the selected object m Tool tips explanatory messages appear when skimming over the toolbar buttons Furthermore some important functions make the software easier and safer to use Multi instance The multi instance function enables several applications to be worked on simultaneously This function enables m Several different applications present on the PC to be opened in offline mode in order to check or copy data m Debugging of two or more applications on two PLCs present on the same network in on line mode This is particularly useful when debugging inter PLC communication functions Application server PL7 Pro software can be launched in OLE Automation server mode from a third party client application In t
157. ject m General information pages m A footer The documentation editor automatically generates m The contents m The application documentation file hardware and software configuration program with its comments including those relating to the macro steps and subroutines m The list of variables sorted by address or symbol m The cross references sorted by address or symbol Runtime screens The runtime screen tool is integrated in PL7 Pro software creation and use of screens It is intended in particular for debugging when starting up installations and for diagnostics on faults or malfunctions It comprises data explanatory texts dynamic values synoptics etc and enables a simple and fast action modification and dynamic monitoring of PLC variables The editor enables the design of these screens using the following tools m Screen creation of runtime screens they can be classed according to family m Message creation of messages used m Objects creation of a graphic objects library When the station is connected to the PLC the user can display screens dynamically depending on the state of the process Screen sequencing is possible depending on the attributed priority via either the keyboard or PLC request In online mode runtime screens enable direct access to the PL7 program from synoptics by simply clicking on the selected object It is also possible to activate the animation table functions or cross r
158. l Backup changeover time 1 to 2 s Warm Standby 43566 6 Development of a multi PLC data server Nano Micro Premium Quantum Momentum TSX Series 7 April Development of a multi PLC data server accessible by Client applications m Access to server in local or remote mode m Access to varaibles in the form of symbols in one or more PLCs m Management of Uni TE and Modbus protocols m Programming in Visual Basic or C m Simulates access to variables for debugging OFS 43105 3 0454Q EN FM 3 Installation Y PL Junior lt Sans nom gt Fichier Edition Services Vue Applicaton AP Debug alemaal gt o 1 amp s SelB sil ES LD MAST section_LD D placer Supprimer Initialiser une table d aramation R f rences crois es Y Le saviez vous Faltes apparaitre des info bulles en survolant les boutons de la barre d omatils oj Vue Outie AP Debug Options Fen te 2 IDEDFS lol cle gt Sale z SIMD 41 bon services Yue Oi AP Debug Options Fentie 2 ml ojal alale a elm sE a PC terminal Dis_desh Booy ii Ce T il He Micro at E PC terminal Server PC terminal Client Applications Client Automation Automation Fipway Prem
159. l Station w 0 Digital Indicator Push Button 00 Message Display Rotary Selector Display Link 0 10 12 37 AM Trend Recorder 4 r 10 16 14 AM Horizontal Slider Diagnostic proctde Microsalt Internet Explorer He Edi Yim 3o Zwee E EJ 2 a 3 Ff 3 A Sbp Ne tesh l me Teach avoiks listo Chemes Fulscres in oe Acdcos 2 hllp fesIpOC TErch hw E ceau iagnzsl him Doce 3h ond inliacet Pane zz FactoryCast Configurator untitled File Transfer Server Language Help Symbols Direct Addresses Write Enabled Write Enabled Symbol Address Data Type M Evt_4 M4 BOOL van M Evt_3 M3 BOOL Evan M Evt_2 196M2 BOOL Evan M Evt_1 196M1 BOOL Evan M Comp_vid_a_reconf_in_progr 96MWYW201 0 X15 BOOL CRec M Cpt vid_b_command_in_progr MW200 0X1_ BOOL CEch M Trig_prod_b 12 BOOL Trig Transfer Web Files 195 6 140 163 i Refresh f Find Rename pelete Make Directory Local System Remote Site l wwwroot y a Name Size L I ftpc properties 9 25 01 5 30PM 153 CA egi bin a 2 WebUtility bat 11 2 00 1 11 PM 113 LJ classes E WebUtilityDebug bat 1 30 01 2 27 PM 112 CA conf 8 wuc ico 9 4198 7 39 AM 766 C limages secure Jj unsecure E Bande gif 23 509 E Ifcast swf 3 756 E hibanner gif 28 580 E index htm 1 940 y
160. le or TSX SCY 21601 1 2 19 2 Kops module 20 mA CL TSX SCP 112 0 105 1 2 19 2 Kops _ Asynchronous serial link connection accessories Description Use Reference Weight E a r kg 1 Terminal port Isolation of RS 485 signals end of line TSX P ACC 01 0 690 connection box adaptation roa ARE supplied with cable for connection to PLC length 1 m Connecting cables for asynchronous serial links Description Use Length Reference Weight From To kg Cables for TSX SCP 114 RS 485 RS 422 3m TSX SCP CX 4030 0 160 isolated RS 485 card device 2 connection Integrated RS 485 RS 422 3m TSX SCY CU 6030 0 180 channel device 3 channel 0 via TSX SCA 50 module box TSX SCY 21601 Cable for Micro Premium RS 232 D port 3m TSX PCD 1030 0 170 non isolated port TER or AUX of a terminal RS 485 connection or TSX PACCO1 device DTE box 3 Cables for TSX SCP 111 card Communication 3m TSX SCP CC 1030 0 190 RS 232 D device connection Modem converter etc DCE 3 Point to point 3m TSX SCP CD 1030 0 190 terminal device DTE 3 10m TSX SCP CD 1100 0 620 Cable for TSX SCP 112 Current loop 3m TSX SCP CX 2030 0 160 20 mA CL card device connection 2 Other Please consult our specialist catalogue connecting cables 1 Product supplied with a bilingual Quick Reference Guide English and French 2 End of cable fitted with flying leads 3 End of cable fitted with a 25 way male SUB D connector Characteristics page 43596 2 Schn
161. le Modem serial link 7 Application Uni TE Modbus Uni TE Modbus 6 Presentation 5 Session Transport TCP TCP 4 2 Ethernet Il or LLC IEEE 802 2 Link MAC IEEE 802 3 PPP 1 Physical CSMA CD IEEE 802 3 RS 232 point to point Today the distributed automation applications can use a unique communication network which meet the needs of real time workshop performance as well as the open access requirements for the monitoring commanding software based upon products using standard communication protocols or applications using Internet technology Ethernet and the point to point protocol PPP via serial link respond to different requirements in terms of data rate capacity for open access on TCP IP and flexibility in terms of topology Ethernet communication affects essentially the following applications m Co ordination between programmable PLCs m Local or centralized supervision Communication with production information management Communication with remote inputs outputs The various services offered are as follows m The TCP IP protocol standard permits communication with o the Quantum platforms in the Modbus messaging with the 140 NOE 771 e0 module o the M1E CPUs associated with the Momentum inputs outputs I O base in Modbus messaging O the Premium platforms with TSX ETY 110 module outside of Ethway profile or TSX ETY 410e 510e module O aPC terminal which supports a standard browser for the Ethernet network o aPC
162. le authorizes a connection with longer lengths up to 10 m 3 490 NTW 000e8 shielded twisted pair cable connection right of the module rep 10 100Base T to Ethernet via hub see page 48190 7 Length from 2 80 m 4 RS 232 cable between the SUB D 9 connector contacts of the module rep RS 232 and the Modem al Connection for external power supply 24 V see power supply process page 43560 3 43312 EN FM 9 43312 EN FM 10 E Modicon Specifications Micro automation platform Ethernet network and TCP IP Modem serial link Type of link Ethernet Serial link by Modem Structure Nature Local industrial heterogeneous network which Telephone line 1 conforms to the IEEE 802 3 standard Topology a Star shaped or tree structure network Physical interface SSSR Ln Transmission Mode Manchester type baseband Half or full duplex Binary data rate a 10 100 M bits s with automatic recognition RS 232 link to 56 K bits s max Medium 10baseT double shielded twisted pair of type Shielded RS 232 cable crossover DTE DTE STP impedance 100 2 15Q 100baseT Ethernet cable category 5 conforms to standard EIA TIA 568A Configuration Number of stations Point to point connection via normalized RJ 2 point to point link 45 connector enabling a star shaped network to be formed the stations are linked to hubs or switches 64 stations max per network Length NA 100 m max between terminal device and hubs Services and functio
163. lectric 816464 816465 816466 References Connection interfaces Telefast 2 pre wired system Passive connection sub bases Function No No ofterminalsLED Polarity Isolator lI Type of Reference Weight of per on per distribution Fuse F connection chan chan row chan per nels nel number nel channel kg Adnan Input 8 141 1 No No a Screw_ ABE 7H08R10_ 0 187 ABE 7H16R50 or Output Yes No Screw ABE 7H08R11 0 187 2 2 Yes Oor24V Screw ABE 7H08R21 0 218 l Screw ABE 7H08S21 0 245 12 1 1 No No Screw ABE 7H12R10 0 274 Yes No Screw ABE 7H12R11 0 274 2 No No Screw ABE 7H12R50 0 196 2 2 No Oor24V Screw ABE 7H12R20 0 300 Yes Oor24V Screw ABE 7H12R21 0 300 Screw ABE 7H12S21 0 375 16 1 1 No No Screw ABE 7H16R10 0 274 Yes No Screw ABE 7H16R11 0 274 Spring ABE 7H16R11E 0 274 ABE 7H16R31 _ 2 No No Screw ABE 7H16R50 0 196 Spring ABE 7H16R50E 0 196 2 2 No Oor24V Screw ABE 7H16R20 0 300 Yes Oor24V Screw ABE 7H16R21 0 300 Spring ABE 7H16R21E 0 300 Screw ABE 7H16S21 0 375 Spring ABE 7H16S21E 0 375 3 3 No O and 24 V Screw ABE 7H16R30 0 346 Yes Oand 24 V Screw ABE 7H16R31 0 346 Type2 16 2 2 Yes Oand24V Screw ABE 7H16R23 0 320 x o AAA input 1 j DS gt NE Input 16 2 1 Yes 24V I F 2 Screw ABE 7H16S43 0 640 t Output 16 2 1 Yes OV F 2 Screw ABE 7H16F43 0 640 ABE 7H16043 1 For Modicon TSX Micro Premium and Numerical Controller NUM 1020 1060 2 With LED to in
164. llowing standard network management tools to monitor and diagnose the network and thus are a key architectural component for real time and deterministic network communication e Transparent Factory Transceivers provide connections to fiber optic networks in order to secure transmissions in areas of high electromagnetic interference The use of multiple transceivers enables long distances between islands e Transparent Factory Bridges enable Modbus to Ethernet and Modbus Plus to Ethernet communications with multiple ports allowing flexibility among network components e Transparent Factory Cables connect each device such as PLC l O PC etc to the attached hub switch transceiver patch panel or to cascade hubs and switches TF cables are available in fiber optic and twisted pair options with a wide variety of connectors and cable lengths 200 Mbps full duplex redundant fibre optic ring Switch Switch Transceiver A iis T 2 THe a nom HIE I i 5 Optical fibre I th Transceiver Quantum Premium El Fibre optic loop Hub Hub Quantum Magelis Altivar Momentum I O All the TF components of the Ethernet wiring system are designed to operate in severe environments TF switches and TF hubs include mechanisms designed to
165. m2 Used to connect the I O of modules with HE 10 type connectors 1 to Telefast 2 connection and adaption rapid wiring interfaces 2 The cable 5 comprises 2 moulded HE 10 type connectors 6 and a cable suitable for carrying higher currents 500 mA maximum TSX CDP 053 length 0 5 metres TSX CDP 103 length 1 metre TSX CDP 203 length 2 metres TSX CDP 303 length 3 metres TSX CDP 503 length 5 metres Connections pages 43051 11 to 43051 13 Schneider Electric Connection principles Micro automation platform continued Discrete I O modules description Connection to Tego Dial and Tego Power systems The TSX DMZ 16 DTK 1 module is specially designed 1 for association with Tego Dial and Tego Power 2 systems Connection is achieved by simply connecting cable TSX CDP ee3 2 to the APE 1B24M Dialbase sub base 3 installed on the Dialpack console 4 which is fitted with a mounting plate 5 for MMI components Discrete I O modules connected via screw terminal block Half format or standard format I O modules with connection via screw terminal block 2 comprise 3 1 A rigid metal casing 4 2 A locking mechanism for fixing the module in its slot This can only be accessed when the terminal block is removed Haltiormav r standard format i o moduls 3 A removable screw terminal block for connection to sensors and preactuators 4 A cover for the terminal block screws which also serves as a label holder Discrete I O mod
166. mary nominal voltage Primary voltage range Mains frequency limit Maximum time of immunity from micro power cuts Secondary nominal voltages Voltage limits Output current Secondary useful power TSX SUP A05 output currents 7 Current in A at 24 V l l l l T 1 qT T 0 1 2 3 4 5 Current in A at 30 V AS i rms insulation between primary and secondary V rms 3500 Withstand to electrical fields V m 10 Safety extra low voltage SELV a Yes Emission withstand class yy FCC class A Conformity to PLC IEC 1131 1 IEC 1131 2 standards Vibrations IEC 68 2 6 Fc 2 gn marine standard IEC 68 2 6 Fc 1 gn marine standard IEC 945 IEC 945 Shocks A IEC 68 2 27 15 gn 11 ms Temperatures Operation 10 60 Storage 25 70 1 The TSX SUP A05 power supply unit is a power supply with constant maximum output Power not consumed on one output is available to another output Output current must correspond to the graph shown above Description Current at secondary Reference Weight voltages 2 30 V 24V Ld AS i bus kg 3 100 120Vand 24A 7 TSX SUP A02 1 050 i 200 240 V y 50 60 Hz module TSX SUP A02 100 120Vand 5A 1 7A 1 TSX SUP A05 2 250 200 240 V 50 60 Hz unit 1 Power supply unit with constant maximum output see graph above TSX SUP A05 Dimensions page 43612 2 Schneider Electric 43612 EN FM 3 Presentation description Micro Automation Platform Integra
167. mily allowing the user to create a sequential library of functions written in C language These functions which will eventually form a part of the PL7 library can be m Used in all languages m Displayed by the PL7 library tool m Classed according to family function The user has the following data at his disposal m Date of creation and generation of the function m The version number of the function family Editing functions The various SDKC software editor tabs enable the user to create the function by m Declaring the interface name type and comment for each input output or I O parameter m Writing the source code file in C language m Declaring the constants as separate files A function written in C language can access numerous internal PLC services such as real time clock PLC variables system words mathematical functions In particular it is possible to carry out numerical processing in floating point format if the target PLC allows Schneider Electric Setup continuea reference HE PL7 Junior MAX_TABW Fichier Application AP Debug Options Fen tre 2 Registres Variables locales Mixer C Asm Go F5 Step Into Fe Step Over F10 Step Out Shift F Step to Cursor F Points d arr t Ctrl B Mise au point EF Mise au point sur l EF MAX_TABW Famille 8762 Programme Classe 1 Num ro 1 Nombre de points d arret pos s 1 Automate en RUN Aret sur le point d arret C ASAWTEMP
168. n Two handed control module Safety module integrated in PLC For further details on components for safety applications please consult our specialist catalogue Schneider Electric Presentation continuea Micro automation platform Use of Preventa safety modules The control signal from the protection device emergency stop pushbutton illustrated to the left acts directly on the power contactor of the machine In this type of scheme the risks of simple faults are m emergency stop button being shorted m KM1 contactor sticking When the operator presses an emergency stop button the instruction is not processed and another sequence can begin following the emergency stop despite the presence of the fault In the case of failure the safety function 1 is compromised Therefore a reliable intermediate relay system must be used 1 A safety function is a function whose non execution or untimely execution results in the immediate placement of the equipment into a non hazardous position Feedback loop 4 Q KM6 KM5 ANA KM5 Emergency qm J Run stop Preventa safety module Redundancy KM6 KM5 and KM6 contactors with mechanically linked contacts Independent safety circuits Preventa safety modules provide a reliable interposing relay function by eliminating the risks of m A control circuit fault inputs m A power circuit fault outputs m A fault on an internal safety module c
169. n countries and to improve the level of safety for personnel Harmonised European standards establish technical specifications which comply with the minimum safety requirements defined in the corresponding directive Manufacturers must produce machinery which conforms to safety requirements The work equipment directive The user is required to ensure that his range of machines conforms to the use of work equipment by workers at work directive Directive 89 655 EEC lays down the minimum objectives for protection in the working environment and in particular concerns the use of products The directive specifies the general framework of preventative measures which should be taken in the workplace All dangerous areas must be identified and have restricted access controlled in a secure manner ie any breakdown or careless operation must leave the automated system in a safe position It should be noted that the use of safety products does not necessarily mean that the machine conforms to the machinery directive It is the operation wiring compatibility and scheme used which make the entire machine safe It is more important to think in terms of safety solutions rather than safety products Groupe Schneider specialists in safety has a range of several thousand products all concerned directly or indirectly with safety Some of these products are exclusively designed for safety all Mushroom head E Preventa safety emergency stop butto
170. n the internal RAM memory and the PCMCIA memory card if the TSX 37 21 22 PLC has a memory card m The application data zone which is always is the internal RAM memory m The application program zone in the internal RAM memory or on the PCMCIA memory card m The constants zone in the internal RAM memory or on the PCMCIA memory card m The Flash EPROM zone for the application program backup the constants and 1 K internal words m The file storage zone in the PCMCIA memory card If the content of the RAM memory is lost battery fault or no battery then the content of the Flash EPROM memory program constants and 1 K internal words is automatically transferred to the internal RAM memory The backup copy of the application in the Flash EPROM memory requires that the PLC does not have a PCMCIA memory extension card and that the size of the program and the constants does not exceed 16 Kwords Two types of application memory organization are possible for Micro PLCs depending on whether the PLC is equipped with a memory extension in the form of a PCMCIA card Application in the internal RAM The application is loaded entirely in the battery backed internal RAM of the processor with a capacity of m 11 Kwords for TSX 37 05 08 shared for example as 2 Kwords of application data and 7 Kwords of the program and its constants m 14 Kwords for TSX 37 10 shared for example as 500 words of application data and 13 5 Kwords of the program and its con
171. nd Via screw terminal TSX DSZ 32T2 0 420 block supplied 24 V 2 A 4 Half Via screw terminal TSX DSZ 04T22 0 310 TSX DMZ 16DTK protected block supplied m AO 24 V 8 Half Via screw terminal TSX DSZ 08R5 0 260 relay not or block supplied protected 24 240 V 32 Stand Via screw terminal TSX DSZ 32R5 0 580 block supplied Number of I O No type of No type of Format Connection Reference Weight inputs outputs kg 16 8 24V 8 solid state Half Via HE 10 type TSX DMZ 16DTK 0 160 2 positive log 24 V 0 5 A connector 1 and IEC type 1 protected encl terminal block 28 16 24 V 12 solid state Stand Via HE 10 type TSX DMZ 28DTK 0 330 positive log 24 V 0 5 A connector 1 IEC type 1 protected Via screw terminal TSX DMZ 28DT 0 465 block supplied 16 24 V 12 relay Stand Via screw terminal TSX DMZ 28DR 0 500 positive log 50 VA block supplied IEC type 1 not protected or negative log 16 12 relay Stand Via screw terminal TSX DMZ 28AR 0 500 y 100 120 V 50 VA block supplied IEC type 2 not protected 64 32 24 V 32 solid state Stand Via HE 10 type TSX DMZ 64DTK 0 410 positive log 24 V 0 1 A connector 1 IEC type 1 rotected 1 Module supplied with HE 10 type connector cover 2 Module compatible with Tego industrial control installation system please consult your Regional Sales Office TSX DMZ 64DTK Specifications Connections pages 43051 5 to 43051 8 pages 43051 11 to 43051 13 Sc
172. nductive overvoltages in ne Against inductive overvoltages in Consumption Dissipated power per module Isolation Betw outputs and Test ground voltage Betw outputs and internal log Insulation resistance References pages 43051 9 and 43051 10 43051 EN FM 8 Micro automation platform Discrete I O modules tputs connection via screw terminal block 1 TSX DSZ 08R5 TSX DMZ 28DR TSX DMZ 28AR TSKXDSZ32R5 8 12 12 32 19 264 10 34 Normally open 3 5 A max per common of each group of channels 2 7 A max per common of each group of 16 channels A a ll ae da aka 200 240 200 240 gt al Oo Ble N BO NaN an A 24 7 10 9 10 11 50 3 50 5 110 10 220 2 24 24 1 x 106 operations 12 0 6 x 106 operations 40 0 3 x 106 operations 24 0 3 x 106 operations 48 0 15 x 106 operations 24 10 2 x 106 operations 6 0 12 x 106 operations 24 1 x 106 operations 12 0 06 x 106 operations 24 0 3 x 106 operations lt 10 lt 10 None obligatory mounting of a fast blow fuse per channel or group of channels None obligatory parallel mounting of an RC circuit or an MOV ZNO peak limiter appropriate to the voltage None obligatory mounting of a flywheel diode on the terminals of each preactuator See page 43311 2 1 5 4 5 5 6 3 5 rms 2000 50 60 Hz for 1 min rms 2000 50 60 Hz for 1 min O gt 10 at 500 V 1 Characteristics at
173. nector for connecting the device TSX MBP CE 030 060 drop cable for Modbus Plus PCMCIA card equipped on the PCMCIA side with a 20 way miniature connector and with flying leads on the 990 NAD 230 00 010 local site tap side In lengths of 3 or 6 m 990 NAD 211 10 30 drop cable equipped on the device side with a 9 way SUB D connector and with flying leads on the 990 NAD 230 00 010 local site tap side In lengths of 2 4 or 6 m 10TSX MBP CE 002 drop cable for Modbus Plus PCMCIA card equipped on the PCMCIA side with a 20 way miniature connector and on the network side with a 9 way SUB D connector Can be used as an extension for cable 990 NAD 211 10 30 In lengths of 0 2 m 11 AS MBKT 185 set of 2 line terminators impedance adaptor for IP 20 local site tap 990 NAD 230 00 to be placed at each end of the segment 990 NAD 230 11 set of 2 line terminators impedance adaptor for IP 65 local site tap 990 NAD 230 10 to be placed at each end of the segment 12170 XTS 021 00 set of 2 line terminators impedance adaptor for tee 170 XTS 020 00 to be placed at each end of the segment Schneider Electric References Micro automation platform Modbus Plus network Description Number per Use Ref Compo Reference Weight PLC no sition 1 kg Modbus Plus 1 with Micro Type III slot on 1 1 type III TSX MBP 100 0 110 PCMCIA card TSX37 21 22 TSX 37 21 22 PLC PCMCIA 1 with TSX 57 10 20 30 40 card Premium processor TSX PC
174. ned for example m Filter values for discrete I O m Voltage or current range for analog I O m Threshold values for counting m Path of axes for position control m Calibration change during weighing m Transmission speed for communication 1 PL7 Junior Pro function available on a Premium platform 2 PL7 Junior Pro function available on a Premium platform based on a TSX P57 353 453 processor Schneider Electric Software structure Micro Automation Platform PL7 Micro Junior Pro programming software PL7 Micro Junior Pro software offers two types of structure m Single task this is the simplified structure offered by default where a single master task consisting of a main program comprising several sections and subroutines is executed m Multitask this structure which is better suited to high performance real time applications consists of a master task a fast task and event triggered tasks which have the highest priority Master and fast tasks are divided into sections Structured and modular programming Mast Fast PL7 program tasks comprise several parts called sections and subroutines Alarm_Sas LD Each section can be programmed in the appropriate language for the processing to be carried out Furnace_1 Grafcet Such division into sections enables a structured program to be created and program modules can easily be generated or added Subroutines can be called from any section of the task to which they belo
175. nform to the Micro PLC requirements see page 43050 11 which meet the following standards ISO IEC 8802 3 ANSI IEEE Std 802 3 4th edition 1993 07 08 conforming to the FCC B rule for radiated emissions 50082 1 1 Transmission via Modem can also be by radio or satellite 2 Requires a standard browser on the PC i e Internet Explorer version 4 Netscape version 4 05 or other which is capable of executing Java code 3 Services available on the TSX ETY 510 module Schneider Electric References Micro automation platform dimensions Ethernet network and TCP IP Modem serial link Designation Data rate and communication profile Integrated Web Server References Weight Diagnostics Web user pages kg y Ethernet modules Ethernet 10 100 M bits s or yes TSX ETZ 410 0 280 for Micro Modem 56 K bits s aae RUA availahla TOY ET 8 Mb lable TSX ETZ 510 Fel TSX 37 10 21 22 Uni TE on TCP IP or Modbus a call pec a PLC on TCP IP e 1 2 a E Connection cables and accessories E Designation From To Use Length References Weight 3 kg gt Ethernet twisted TSX ETZ 410 510 Ethernet Hub Link to Ethernet 2m 490 NTW 000 02 i c shielded cables module RJ 45 connector network 5m 490 NTW 000 05 F Y Y O a y E 3 RJ 45 connector See page 48190 7 12 m 490 NTW 000 12 Y j add ETH A A A A A 40m 490 NTW 000 40 PA E E 80 m 490 NTW 000 80 7 RS 485 Uni Telway TSX ETZ 410 510 Compatible PC Uni Telway bus link 2 5m TSX PCU 1
176. ng or from other subroutines in the same task Cleaning ST There are two types of cyclic execution m Normal cyclic execution This is the default option m Periodic execution This type of execution as well as the period are selected by the user during configuration Normal execution cyclic At the end of each scan the PLC system launches the execution of a new scan The execution time of each scan is monitored by a software watchdog whose value is defined by the user Internal processing Input acquisition l RUN l Ez Program processing Update of outputs 0 In the event of overrun a fault occurs causing m The scan to stop immediately STOP m A display on the front panel of the PLC m The alarm relay of the main rack power supply to be set to 0 Periodic execution aunc of the period A new scan is executed at the end of each period The execution time of the scan must IL be less than the time of the period defined 1 to 255 ms In the event of overrun E the latter is stored in a system bit S19 which can be set to O by the user by program or by the terminal E i A software watchdog which can be configured by the user monitors the scan time RON In the event of overrun an execution fault is signaled see normal execution Update of outputs 0 E Internal processing End of period Characteristics References pages 43100 13 to 43100 15
177. nguage etc One section is dedicated to Grafcet language when chosen 3 processing operations are proposed E Preliminary processing PRE is programmed in Ladder Structured Text or Instruction List language and processes initializations on power return operating mode modifications input logic E Sequential processing CHART includes the graphic transcription and management of Grafcet charts It provides access to processing of the actions and transition conditions E Post processing POST This is programmed in Ladder Structured Text or Instruction List language and is used to process all the instructions from the 2 preceding processing operations and the indirect safety functions specific to the outputs Fast task This task which is higher priority than the master task is periodic in order to leave time for execution of the lower priority task Processing operations in this task must be as short as possible so as not to adversely affect the master task It is useful when fast periodic changes in discrete inputs need to be monitored Each section of this task can be programmed in Ladder Structured Text or Instruction List language Event triggered tasks Unlike the tasks described above these tasks are not linked to a period Their execution is triggered by an event occurring in an application specific module eg overrun of a counter threshold change in state of a discrete input These tasks have higher priority than all oth
178. nior software enables programming in Instruction List Ladder Structured Text and Grafcet language It can also be used to set up application specific functions and undertake maintenance and diagnostics of the developed applications It includes the PL7 2 PL7 3 and ORPHEE application converters Description PL7 junior software packages Software updates for previous version of PL7 Junior Software upgrade For PLCs Micro Premium PCX Premium Micro Premium PCX Premium Micro Premium packages from previous PCX Premium version of PL7 Micro Type 1 station device 3 station device 1 station update 3 station update 1 station upgrade 3 station upgrade PL7 Pro development software packages Reference Weight kg TLX CD PL7J P 42M TLX CD3 PL7J P 42M TLX RCD PL7J P 42M TLX RCD3 PL7J P 42M TLX UCD PL7J P 42M TLX UCD3 PL7J P 42M Functions on PL7 Pro software are identical to those on PL7 Junior software It also offers the user the possibility of creating his own function blocks DFBs and graphic runtime screens Description PL7 Pro software packages PL7software package Pro OpenTeam 1 PL7software package Pro OpenSite 1 PL7 software For PLCs Micro Premium PCX Premium Micro Premium PCX Premium Micro Premium PCX Premium Micro Premium PCX Premium Type 1 station device 3 station device Device with between 3 and 8 user stations for a geo
179. nnection From Cable Integrated analog I O section 15 pin SUB D type 0 205 mm connector Functions performed Adjustment of constants using 4 integrated potentiometers Adaptation to 0 20 mA current 4 20 mA adaptation to 8 discrete 24 V channels 15 pin SUB D type connector Connection via screw terminal block with integrated channels Length to m Base 0 5 ABE 7CPA01 15 pin 4 SUB D type connector 25 Reference 1 TSX ACZ 03 TSX CAP S15 ABE 7CPA01 Reference 1 TSX CCP 15 050 TSX CCP S15 100 TSX CCP 15 Weight 0 075 0 050 Description Functions performed Connection terminal block TSX AeZ Batch of 4 resistors module supplied with module TSX AEZ 414 Connection to terminal screw block supplied with module Reference 1 TSX BLZ H01 Adaptation for 250 Q 0 1 current range for TSX AEZ 414 TSX AAK2 1 Product supplied with TSX BLZ H01 screw connection terminal block and bilingual installation guide English and French 43053 EN FM 7 Micro automation platform Process control of semi continuous processes Micro and Premium PLCs have as standard process control functions which can be accessed by the user via the PL7 Micro PL7 Junior or PL7 Pro programming software These functions are particularly suitable for m Sequential processes requiring auxiliary process control functions such as wrapping machines surface treatment machines presses
180. nnection via 20 way HE 10 connector 8 12 or 16 channels with or without LED with common or terminals per channel Inputs 16 channels 5 V TTL 24 V 48 V 48 V 115 V or 230 V 2 terminals per channel Outputs 8 or 16 chann with 1 N O 1 or 2 C O or solid state relays 5 48V 24 V 24 240 V 1 or 2 terminals per channel Yes see page 15000 2 Yes see page 15020 2 Type 1 Type 2 Type 1 Positive Negative Positive 2 wire 2 wire n 2 wire 2 wire 3 wire PNP NPN 3 wire PNP Configurable falloack of outputs Preactuator voltage monitoring Configurable fallback of outputs Yes Non protected Protected TSX DMZ 28DR TSX DMZ 28AR 43051 9 Schneider Electric Positive TSX DMZ 28DT TSX DMZ 28DTK TSX DMZ 64DTK 0466Q EN FM 3 Micro automation platform Discrete I O modules 12 inputs 8 inputs 8 outputs Inputs 24 V Inputs 100 120 V Inputs y 200 240 V Outputs relay 3 A th Connection via screw terminal block supplied with the module Sensor voltage Sensor voltage Sensor voltage monitoring monitoring monitoring Type 1 Type 2 Type 1 Positive negative 2 wire 2 wire n 2 wire 2 wire 3 wire PNP NPN Configurable fallback of outputs Non protected 43051 9 0467Q EN FM 2 Schneider Electric 4 outputs 8 outputs 12 inputs Outputs 24 V 2 A Ouputs
181. ns supported by the module Shared services Different shared services scanned inputs outputs service performed from the Premium Quantum PLC with the I O Scanning function inter PLC communication in Uni TE or Modbus TCP IP download of Uni TE PL7 applications diagnostics module remote terminal Terminal transparence see page 43300 3 adjustment debugging and modifications to the program in Uni TE client server mode 32 simultaneous connections 128 byte client server requests Synchronous mode 1Kbyte client server requests asynchronous mode In Modbus client server mode 32 simultaneous connections 128 byte synchronous requests TCP IP services Different Integrated Web server services maximum simultaneous connection of 8 standard browsers IP configuration for TSX ETZ 410 510 module via standard browser PLC diagnostics system function RackViewer communication diagnostics function access function to the PLC data and variables Data Editor graphic objects editor 3 Web pages defined by the user 8 Mb available 3 Integrated Web server function 2 Electrical specifications Supply voltage Nominal 24 Limits 19 2 30 Wave rate 5 max Accepted micro cuts Permitted overvoltage 34 max for 1 hour in 24 100 50 200 Power consumption Nominal Limits Power dissipation 2 4 4 max without consumption on terminal port Environment Conforming to standards The TSX ETZ 410 510 modules co
182. o 200 240 V TSX SUP A05 power supply unit It comprises An ON indicator lamp orange mains supply present An AS i indicator lamp green 30 V supply present on the AS i bus A 24 V indicator lamp green 24 V supply present for the auxiliary power supply Two screw terminals AS i and AS i for connection to the AS i bus and one terminal to connect the shielding when using a shielded bus cable Four screw terminals for the 24 V output Three screw terminals for connection to the network Two terminals to select the primary voltage N 110 120 V and 200 240 V OND N OO These two power supplies conform to the fixing dimensions of Micro PLCs TSX SUP A02 SUP A05 and Premium PLCs TSX SUP A05 which enables them to be mounted independently on rails next to Micro Premium PLCs or in the case of the TSX SUP A02 module power supply in a TSX RKY ee rack of the Premium PLC TSX SUP A02 Power supply module TSX SUP A05 Power supply unit Mounting bracket provided l O Y RIA CoE Specifications References page 43612 3 page 43612 3 43612 EN FM 2 Schneider Electric Specifications Micro automation platform references AS i bus power supply module and unit Type of power supply module SII IS A i 2 4 at 60 C 2 8 A peak See output currents graph at 60 C 72 at 60 C See output currents graph at 60 C Pri
183. o format m Conversion ensures that instructions which are translated are functionally identical to the original program E A translation report gives a summary O result of the conversion with the cause of non translation where possible O correspondence of variables in PL7 with original variables Functions PL7 2 and PL7 3 converters Series 1000 converter Program and data From any TSX Series 7 PLC From any ORPHEE program conversion program Conversion of Partial or total objects All types of data Constants for PL7 2 and PL7 3 only Retrieval of symbols and comments Address reassignment service I O addressing Reassignment of each channel individually or for each module possibility of having several modules on the same slot for different modularity Conversion of Partial or total Partial or total program Source modules exported from Cyclical and background PL7 2 or PL7 3 combinational logic Ladder or Structured Text MAIN Cyclical and background PRE POST SRi combination logic Grafcet CHART XMi Task event and diagnostic Retrieval of all comments Processing associated with Grafcet steps Retrieval of all comments 1 Function requiring PL7 Junior Pro software Schneider Electric Characteristics Micro Automation Platform PL7 Micro Junior Pro programming software Ladder language Rung E 16 lines of 10 contacts with 1 output per line on Premium PLC E 7 lines of 10 contacts with 1 outpu
184. ocessing capacity of the devices which are connected For example the remote loading of a 50 K word program CT1 CT1 takes less than two minutes on a network with normal load nal CT1 Cycle time of device 1 NCT Cycle time of Fipway network CT2 Cycle time of device 2 The response time must be evaluated by the designer of each application in relation to the devices connected The processing time of a device can vary from one to two cycle times as a function of asynchronous operation Schneider Electric Connectable devices Premium automation platform references Fipway network Micro Premium PLCs Micro Premium PLCs have a slot on the processor for a type lll PCMCIA communication card This can be fitted with the TSX FPP 20 fipway network connection card which is also inserted into the TSX SCY 21601 communication module slot The TSX FPP 20 card comprises 1 Protective cover 2 Removable cover with fixing screws for access to the 20 way miniature connector 3 Two indicator lamps ERR lamp card fault link fault COM lamp data transmission or reception Connector to be ordered separately 4 TSX FP CG 010 030 1 or 3 m cable for connection to the TSX FP ACC 3 ACC 4 T junction box on 9 way SUB D connector FT2100 PC compatibles Magelis dialogue terminals 999908 dodod al D l O X O il oO xl o a oO D oO D D Oo Connection via Fipio Fipway Equipped with Connection via
185. odules mounting Description Output Rating Parallel Reference Weight Voltage A connection kg V Unit 100 240 V 24 1 No TBX SUP 10 0 290 50 60 Hz and 125 V Module 100 240 V 24 1 1 Yes TSX SUP 1011 0 720 50 60 400 Hz SELV 1 2 and 125 V Modules y 100 120 V 24 2 2 Yes TSX SUP 1021 1 090 and 200 240 V SELV 1 2 50 60 400 Hz 5 Yes TSX SUP 1051 1 120 1 2 Unit 100 120 V 24 10 Yes TSX SUP 1101 2 100 and 200 240 V SELV 1 50 60 400 Hz TSX SUP 1101 1 Product supplied as standard with a bilingual quick reference guide English and French 2 Mounted in TSX RKY 6 8 12 6E 8E 12E racks any slot except the slot for TSX PSYee0M power supply modules on AM1 DE200 DP200 rails or on AM1 PA mounting plate TBX SUP 10 power supply unit Power supply modules TSX SUP 1011 TSX SUP 1021 1051 Mounting support supplied Mounted on AM1 DE200 or AM1 DP200 rail 16 or on AM1 PA mounting plate O O LO LO A LO O LO vo A TSX SUP 1101 power supply unit 1 Distance between centres 1 139 7 mm with AM1 DP200 rail mounted on AM1 PA mounting plate compatible with Micro PLC 2 Mounted on AM1 PA mounting plate AF1 EA6 m mn e O H L TE A AAOS a a ig A 22 iN MiS a a El i o E F AS WY WE m C o Ed E o 8 5 8 Characteristics page 43560 2 Schneider Electric
186. of the application A DFB derived function block is set up in three phases m Design of the DFB which has a name parameters I O variables and code in Structured Text or ladder language m Creation of a DFB instance in the variables editor or when calling the function in the program editor m Using this instance in the program in the same way as a standard function block Variables editor The variables editor is used to m Symbolize the various application objects bits words function blocks I O etc m Define the parameters of the predefined function blocks timers counters registers etc m Enter the values of the constants and select the display base decimal binary hexadecimal floating point message m DFB user function block parameters Each symbol 32 characters max accented characters are permitted can be accompanied by a comment 508 characters max Editing services are available in the editor m Find replace an object in a part of the program or in a set of function modules PL7 Pro m Find a character string in a list of symbols or comments Version 2 V4 0 of PL7 offers enhanced functions due to m Copy paste function for one or more symbol s and comments m Display in plain language of the overlap of different types of variable on a single memory address for example single and double format internal words MWO0 MDO m Highlighting of objects used by the application program m File import e
187. ole BO JK Elchier Edition Services Yue Outils AP Debug Options Fen tre 2 2 OUTI jon f pait dor anl 69 ces aE 11 Tendances 12m Ej 10 Tendances 6 mr Ej 4 Manip_fav_onoll DUCLES 8 Controle BOUCLE 5 OUCLE 6 O Lonkrore D Controle B Controle BOUCLE 4 Controle BOUCLE 3 Controle BOUCLE2 Controle BOUCLE1 Controle defaut Evolution valeurs SOcoccDa g Bi 9 7 6 5 3 1 2 Dyobaticn de signal RpA SP Bvobstion de speed_lkn_ out Byvobaion de li mesure avat rache cares PV y TeeullO wens IPLI 2 _ ____ Q_Q_ T senil 1 w210 C Samne T senil 2 mw12 VO mniso0 Ysw 1 muB02 Y sen 2 20 __ T al Tenio E py Unit Pv Ed bc26 y 251 LOCAL U 2438YS Solvant 56 LITRES 171 LITRES References page 43100 17 Characteristics pages 43100 13 to 43100 15 43100 EN FM 10 Micro Automation Platform PL7 Micro Junior Pro programming software Documentation editor The documentation editor is built around the Documentation Browser which displays the contents of the documentation file in a tree structure It can be used to print all or part of the application documentation file on any graphic printer which can be accessed in Windows and uses True Type technology in A4 or US letter print formats The documentation editor is used to define m A title page including the name of the designer and pro
188. olid state type A ae O0 1A connector N 14 15 161 115 V Via screw TSX 3710 028AR1 1 910 100 240 V Kwords Kwords 12 O relay _ terminalblock data Supplied memory 161 24 V Via screw TSX 37 10 028DR1 1 910 12 O relay terminal block supplied Supply Integrated memories Integrated functions Reference Mass RAM Flash EPROM kg 24 V 20 5 Kwords TSX 3721 101 1 720 Kwords data memory 8 analog inputs 0 10V TSX 3722 101 1 750 1 analog output 0 10 V 1 Up down counter 10 kHz 1 counter 10 kHz N 20 15 Kwords TSX 37 21 001 1 720 100 240 V Kwords data memory 8 analog inputs 0 10V TSX 3722 101 1 750 1 analog output 0 10 V 1 Up down counter 10 kHz 1 counter 10 kHz Reference maximum kg Use Number Capacity 2 slots possibility PLCs 1 mini rack per PLC FSX RKZ 02 of 4 positions TSX 37 10 21 22 S 0 See page 43901 2 roduct supplied with multilingual installation guide English French German Italian an Spanish characteristics Dimensions mounting Micro base and module installation manual pages 43050 11 and 43050 12 page 43050 15 43050 EN FM 13 References continued TSX MRP eeeP TSX FAN esp TSX PRG LDR Description Functions pages 43050 2 and 43050 5 pages 43050 6 and 43050 7 or ae 43050 EN FM 14 Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Extension for application memory Description Use Memory size Reference Mass Application File
189. omponent The safety function remains operative whenever any one of these faults occur For the use of mechanically linked contacts CA2 DN22 DN31 LC1 D09 D18 D25 LP1 D09 D18 D25 with contacts which can be used in the feedback loop please consult your Regional Sales Office Schneider Electric 43308 EN FM 3 Presentation description Simplification using the safety module integrated in the PLC Specifications page 43307 4 43307 EN FM 2 References page 43307 4 Micro automation platform TSX DPZ safety module The TSX DPZ 10D2A emergency stop monitoring module integrated into the Micro PLC combines m The ease of use of Preventa safety modules m PLC diagnostics performance It also maintains all the advantages of a standard PLC extended choice of I O ease of installation flexibility of hardware and software developments etc The TSX DPZ 10D2A emergency stop monitoring module combines a Preventa XPS hard wired safety relay and a discrete acquisition function in a half slot for full diagnostics of input contacts and the state of safety circuit outputs The TSX DPZ 10D2A safety module is used to interrupt one or more emergency or safety stop control circuits in complete safety in accordance with EN 60204 1 The proven safety of hard wired technology and the capacity of the Micro PLC make module TSX DPZ 10D2A the optimum solution for making machines mo
190. on a PLC base output Q2 0 can after configuration be assigned to the ALARM function When setting the PLC to RUN and if no blocking fault is detected the alarm output changes to state 1 It can be used in safety circuits external to the PLC for example to control the output preactuators power supply or the TSX Micro PLC power supply Type of input 24 V 24V 24V N 100 120 200 240 V V Type 1 Type 2 Negative Type 2 Type 1 Positive Positive logic logic logic Type of proximity sensor All 3 wire prox sensors PNP type All 3 wire prox sensors NPN type 2 wire proximity sensor Telemecanique or other brand having the following characteristics residual voltage closed lt 7 V minimum switching capacity lt 2 5 mA residual current open lt 1 5 mA 2 wire proximity sensor ay 2 wire proximity sensor i G a O 1 Compatible 1 In the nominal voltage range 220 240 V Connections pages 43051 11 to 43051 13 Schneider Electric Specifications Module type Number of inputs Connection Nominal input values Voltage current Sensor supply ripple included Input limit values At state 1 Voltage Current At state O Voltage Current Input impedance at state 1 Configurable response time State 0 to 1 State 1 to 0 IEC 1131 2 conformity Proximity sensor compatibility 2 3 wire Isolation resistance Type of input Consumption Dissipated power
191. on between output and earth Temperature Degree of protection Connecting cable c s a TSX DPZ 10D2A Connections page 43307 5 43307 EN FM 4 KN overvoltage category Ill degree of pollution 2 Emergency stop or limit switch discrete ie 8 inputs Feedback loop discrete input MA E SS Vrms 1500 50 60 Hz for 1 min Dissipated in the module WwW lt 45 2 volt free outputs a c 19 264 P A 2 mA 10 Inductive 48 220 AC 15 dut 30 60 140 165 Inductive 24 L R 100 ms ims lt 100 E AN go id flashed Conforming to IEC 947 5 1 ae 4 gl Insulation voltage 300 conforming to DIN VDE 0110 part 2 MS Test voltage Vrms 2000 50 60 Hz for 1 min Without cable end 1 x 0 8 minimum With cable end pe 2x 1 maximum Inputs Number Voltage Safety outputs Connection format Reference Weight 1 kg 4 emergency 24V 2N O Via screw terminal TSX DPZ 10D2A 0 280 stops or limit volt free block supplied switches 1 25 A Ithe Half format dual or 1 Product supplied with a multilingual installation guide in English French and German Schneider Electric Connections Micro automation platform TSX DPZ safety module Category 3 wiring diagrams redundant inputs and outputs recommended applications Connection of 4 sensors with dual contacts Connection of 4 sensors with dual contacts for existing installations The states of all
192. or SUB D connector 35 9 30 possible up to 34 V limited to 1 hour per 24 hours HE 10 connector screw term block 24 positive logic O 7 gt 11 wA A v pe ente ol joa 8 D O oO NIA O Na D IA A 101 1 1 5 fixed 2 0 3 fixed gl 3 s type 1 D lt OM n gt AS isi lt 3 lt i i O N al 10 al 500 D lt V esistive Current sink Resistive ep ee page 43311 2 lh lt rms 1500 50 60 Hz for 1 min Vrms 1500 50 60 Hz for 1 min 1 Characteristics at 60 C for 60 I O loading or at 30 C for 100 I O loading 2 Adaptation and analogue adjustment module enables the transformation of 8 integral analogue inputs for TSX 37 22 bases into 8 discrete inputs see page 43053 2 Connections pages 43051 11 to 43051 13 43051 EN FM 5 Specifications continuea Micro automation platform Discrete I O modules Module type TSX DEZ 08A4 TSX DEZ 08A5 TSX DMZ 28AR O A Screw terminal block Screw terminal block Screw terminal block Number of inputs Connection Nominal input values Voltage Current TIA 10 MH 60Hz mA 13 1 Freguenc Hz 47 63 47 63 47 63 Sensor suppl 85 132 170 264 85 132 Input limit values At state 1 Voltage V gt 74 gt 120 gt 74 Current mA 26 for U 74 V gt 6 for U 164 V gt 6 for U 74 V At state 0 Voltage lt 20 Curent MA lt 4 is a
193. order to improve application legibility and development m Cr ation of runtime screens synoptics text values which are displayed depending on the state ofthe process in order to simplify operation and control of an installation m Diagnostic viewer PL7 Micro PL7 Junior PL7 Pro 43100 17 Schneider Electric 0454Q EN FM 2 Application conversion Development of functionsin C language Comparison of PL7 Premium Availability of Premium applications Conversion of SMC PLC applications for Micro Premium PLC applivations m Selection of sequences to translate into Ladder language m Conversion of symbol database m Reassignment of I O m Conversion report PL7 Junior Pro software required PL7 SMC 43107 3 Schneider Electric Enhances the library of PL7 functions by developing functions in C language m Creation of functions families m Development of functions in C langage m Debugging of functions step by step breakpoints etc m Generation of disks forr installation on over PL7 stations m Use of new functions in applications PL7 SDKC 43103 3 Premium Automatic comparison of 2 Premium applications with identification of all the differences PL7 Pro software required PL7 DIF 43107 3 applications Continuity of operation in a Premium PLC redundant architecture automate Premium Possible to have shared I O on a Fipio bus or redundant I O Typical Norma
194. ors RJ45 connectors 2 100baseTX ports with RJ45 connectors 2 100baseFX ports with SC connectors Twisted pair cables Twisted pair cables or redundant fibre optic ring 1 x 5 way 5 10baseT 100baseTX ports with shielded V 18 32 safety low voltage Power supply Ring structure and or twisted pair Switching time lt 0 3 s Redundancy manager 800 max 100 max with twisted pairs Fibre optic 3100 max Twisted pairs 100 max 50 max 4 max at 10 Mbps 50 max at 100 Mbps Power supply fault Ethernet networt fault or communication port fault volt free contact 1 A max atu 24 V Power supply data exchange collision and line status via communication port Schneider Electric Characteristics continuea Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface Mechanical characteristics Models Operating temperature Relative humidity Dimensions Lx H x D Degree of protection Approvals and conformity Electrical characteristics Models Types Interfaces Medium Connectors Operating voltage Redundancy Consumption at 24 V Line length Max link attenuation Indicator lights 499 NTR 000 10 499 NTR 001 00 C 0 to 60 10 90 without condensation 40 x 140 x 80 IP 30 UL CE CUL 1950 FCC part B CSA 22 2 142 CSA 22 2 213M class 1 Div 2 certification pending 499 NTR 000 10 499 NTR 001 00 Ethernet 10 Mbps Ethernet 100
195. otected common No Screw 3 wire proximity Isolator and sensor fuse indicator Telemecanique Solid state fixed Solid state removable Yes No From 24 V From 5 V TTL to 230 V to 230 V 12 mA Signal Signal and common Yes No Screw or spring 14025 4 14025 5 0113Q EN fm 5 Connection interfaces Telefast 2 pre wired system Analogue sub bases Micro Premium Standard Counter inputs and Counter inputs Analogue inputs Analogue outputs analogue I O Axis control Current Current Position control Voltage Voltage Pt 100 Passive connection point to point with shield continuity 1 counter channel or 8 analogue inputs 2 analogue 8 channels 4 channels outputs 24V 24V 2 2or4 2or4 i gt 15 way SUB D 9 way SUB D 25 way SUB D caret D gt N 3 Screw Screw a gt 14026 2 0113Q EN fm 6 Schneider Electric 817435 817434 al En Analogue inputs Current Voltage Pt 100 Distribution of sensor power supplies per limiter 25 mA 8 channels 25 way SUB D Schneider Electric Premium TSX AEY810 Isolated analogue inputs Distribution of isolated sensor power supplies per converter 8 channels 25 way SUB D Screw or spring Premium TSX CAYe1 TSX CTY2C Inputs Counting Acquisition of value from an absolute encoder 1 channel 15 way SUB D Telemecan ique Premium TSX AEY1614 Inputs for thermocouples Connection of 16
196. out position feedback pulse widths are proportional to the PID output variation Setting parameters for valve opening times and minimum pulse duration Execution time ms 096 08 0 85 4 l08 0 89 43531 EN FM 3 Schneider Electric Micro automation platform Integrated counter channels and counter positoning modules 1 4 3 2 independent channels 2 independent channels not excluding the 2 upcounter channels on the discrete inputs 500 Hz 450 Hz for incremental encoderwith 10 kHz phase shifted signals 8 ms taking account of an event triggered input and positionning of a discrete module output in master Channels 0 and 1 4 x 24 V inputs for Channel 11 5 24 V for 1 Totem P le or proximity sensors and mechanical contacts RS 422 incremental encoders compatibles with Totem P le incremental Channels 11 and 12 24 V inputs for encoders proximity sensors and mechanical contacts 1 input per chamnel preset 1 24 V input per channel preset using 2 counter input 24 bits sign 0 to 16 777 215 points or 16 777 215 points Downcounting with preset input upcounting with reset input Up down counting with preset input configurable counter input 1 upcounter input 1 downcounter input 1 up downcounter input and 1direction input incremental encoder with phase shifted signals or proximity sensor Inputs Counter enable counter present Comparison Downcounting
197. page 43100 17 Schneider Electric 43100 EN FM 5 Software structure continued Micro Automation Platform PL7 Micro Junior Pro programming software PL7 Micro Junior Pro software offers a Multitask software structure consisting of m A master task divided into sections one of which may contain Grafcet E A fast task divided into sections m One or more event triggered tasks only one section per task These tasks are independent and are executed in parallel with the PLC processor managing the execution priority When an event occurs or at the start of the fast task cycle m The current execution of lower priority tasks is stopped m The event triggered task or the fast task is executed m The interrupted task takes over again when processing of the priority task is completed Fast task Master task Event triggered tasks Alarm_Sas L Sas LD Safety_Mon L Furnace_1 LD D D ST Alarm_Cleaning POST IL Drying LD This structure can optimize use of the processing power and can be used to structure the application and simplify design and debugging as it is possible to write and debug each task independently of the others Master task This compulsory task which executes the main program is periodic or cyclic see single task structures It is activated systematically It is intended for sequential processing Each section can be programmed in Ladder Structured Text Instruction List la
198. plex connector MT RJ ST connector MT RJ MT RJ connector Description Use Mini transceiver For connecting a 10base5 interface device 1 toa 10baseT Ethernet network segment twisted pair Type of platform Description Micro External module 10 100 Mbp s Momentum M1E processor 1 Modbus M1E processor 1 I O bus Comm adaptator 10 Mbps Premium 10 Mbps modules 10 100 Mbps modules Quantum 10 100 Mbps module 100 Mbps module Available ports Reference Weight kg 4 10baseT ports 499 NEH 004 10 0 520 3 10baseT ports 499 NOH 005 10 0 900 2 10baseFL ports 4 100baseTX ports 499 NEH 041 00 0 520 5 10baseT 100baseTX ports 499 NES 071 00 1 450 2 100baseTX ports 5 100baseTX ports 499 NOS 071 00 1 450 2 100baseFX ports 1 10basel port 499 NTR 000 10 0 520 1 10baseFL port 1 100baseTX port 499 NTR 001 00 0 520 1 100baseFX port Ethernet ports available Reference Weight kg 1 10baseT RJ 45 type 174 CEV 200 30 4 260 or 10base2 BNC type or 10base5 AUI type port 1 10baseT port RJ 45 type 174 CEV 300 10 0 500 Length Reference 2m 490 NTW 000 02 1 5m 490 NTW 000 05 1 12 m 490 NTW 000 12 1 40 m 490 NTW 000 40 1 80 m 490 NTW 000 80 7 5m 490 NTC 000 05 1 15m 490 NTC 000 15 7 40 m 490 NTC 000 40 7 80 m 490 NTC 000 80 1 5m 490 NOC 000 05 5m 490 NOT 000 05 5m 490 NOR 000 05 Reference Ethernet ports available 1 10base5 port AUI type TSX ETH NT
199. pplication PL73 un Application Orph e El A A Se ooe Application PL72 Fichier Edition Services Application AP Debug Options Fen tre 2 Configuration de l impression r Quitter 1 CAT57_AD STX 2 T57_AD2 STX 3 TSX572 1 STX A GRAF7_AD STX Ouvre le convertisseur PL7 2 Nombre de Blocs Fonctions pr d finis Type Nombre 64 0 Monostables 8 32 Registres 4 16 Rapport de Conversion HE JE JE HE JE JE JE JE JE JE E JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JEJEJEJE FE YE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE EJE JEJE FE Timer s rie 7 Bit tape Lancez l Import du fichier LD Menu Fichier gt IMPORT on co LOCAL The converters offer the following utilities m Translation of language objects into the new PL7 syntax with retrieval of associated symbols and comments E Possibility of manually reassigning objects E Configuration check the tool checks whether the configuration resources required by the program to be converted are compatible with the configuration of the destination application m Conversion 7 with generation of source files Ladder Structured Text or Grafcet in PL7 Junior Pr
200. program m END ENDC ENDCN program end conditional or unconditional m JMP JMPC JMPCN jump to a label L conditional or unconditional E SRn call of subroutine n 0 lt n lt 253 conditional or unconditional m RET RETC RETCN subroutine end conditional or unconditional A generic comment can be associated with each subroutine E NOP blank instruction no action performed E MPS MRD MPP management of buffer memory for divergence towards the output E HALT stop program execution Instructions on bits mg bit NOT RE FE direct read bit status inverse rising and falling edges m OR AND XOR logic operations E SET RESET assignment setting abitto 1 setting a bit to 0 Chart Premium PLC E maximum of 250 steps 2 on 8 pages m 64 macro steps of 250 steps m A generic comment can be associated with each macro step m 1024 transitions maximum 2 m 11 elements maximum per divergence convergence m 1024 steps maximum in the application 2 Number of active steps and number of valid transitions configurable within the number of configured steps and the number of transitions configured References page 43100 17 Schneider Electric 43100 EN FM 13 Characteristics continued References page 43100 17 43100 EN FM 14 Micro Automation Platform PL7 Micro Junior Pro programming software Functions and instructions Predefined function blocks 7 E 64 255
201. r Agent PCMCIA card This consists of m Indicating the connection point number 1 to 127 m Indicating the address at the beginning of the 64 MW word table reserved for sending data to and receiving data from the manager Adresse du point de raccordement Log Adresse de d but de table Mw 100 References page 43593 3 Schneider Electric 43593 EN FM 2 Description Micro automation platform references Fipio bus Agent function Micro TSX 37 21 22 Premium PLCs have a slot in the processor for a type III PCMCIA communication card This can be fitted with a TSX FPP 10 Fipio bus connection card The TSX FPP 10 card comprises 1 A protective cover 2 A removable cover with fixing screws giving access to the 20 way miniature connector 3 Two indicator lamps o ERR lamp card fault link fault o COM lamp transmission or reception of data Connector to be ordered separately 4 TSX FP CG 010 030 1 or 3 m cable for connecting the TSX FP ACC 4 tap junction on 9 way SUB D connector Fipio bus connection component Description Composition Reference Weight kg Fipio Agent 1 type III PCMCIA card TSX FPP 10 0 110 function card 7 Version V1 8 Fipio bus connection accessories 2 TSX FPP 10 Description Use Reference Weight kg Insulated bus Trunk cable tap link supports TSX FP ACC 3 0 090 re cable connector 2 x 9 way female SUB D connectors in black polycarbonate for TSX FP CG 010 030 PCMCIA card
202. r blocks or connection interfaces The maximum number of conventional sensors or actuators which can be connected is therefore 248 A combination of communicating and conventional sensors actuators is possible 0 O Passive T connector Passive splitter block Active splitter block Connection interface Each device connected on the AS i bus is powered by a specific power supply via the AS i cable The size of the power supply must be suitable for the total power consumption of the devices on the bus This power supply can be located at any point on the bus Schneider Electric 43610 EN FM 3 Presentation description diagnostics XVA indicator bank AS i bus XAL Micro automation platform TSX SAZ master module for AS i bus The TSX SAZ 10 AS i bus module enables the Micro PLC to act as the AS i bus master In this way up to 31 sensor actuator type devices may be managed on the one AS i bus Up to 4 inputs and or outputs can be connected to each device giving a maximum of 248 I O on one segment Micro TSX SAZ 10 oooo o 8 bZ L os H A E 8 o o O O a OA o o o ae ILLA S Intelligent keypad control g yP Motor starter TSX SUP A02 station BASE EXT RIO WRD DIAG 2 O 6416 6416 O 6416 O ms pes v0 O ERRO 4 References page 42718 3 42718 EN FM 2 sensors power supply The AS i bus comprises a master station Micro PLC and slave stations The TSX SAZ 10 mo
203. r fixing the module 2 A display block comprising a 24 V green indicator lamp which is on if the internal and output voltages are correct and an LSH power optimization mode orange indicator lamp for TSX SUP 1011 1021 power supply modules only A cover for protecting the terminal block A screw terminal block for connection to the mains supply of the 24 V output A space for the insertion of the cable clamp A 110 220 V voltage selector TSX SUP 1021 1051 modules only A NOR LSH switch located at the rear of the module for controlling the power optimization device TSX SUP 1011 1021 power supply modules only NO oO O ag TSX SUP 1101 process power supply unit The front panel comprises 1 A display block comprising an ON orange indicator lamp which is on if the module is powered up 2 A display block comprising a 24 V green indicator lamp which is on if the 24 V output voltage is present and correct A cover for protecting the terminal block A screw terminal block for connection to the a c supply A screw terminal block for connection to the 24 V output voltage A space for the insertion of the cable clamp Four holes for fixing the module NO 0 E Type of power supply module Nominal input voltage 100 120 200 240 Input voltage limit 90 264 or 85 264 or 85 132 170 264 88 156 105 1150 Accepted micro break period 1 ms lt 10for lt 1for
204. re PNP detector 3 wire NPN detector 2 wire detector Mechanical contact OND O O JO Ol References page 43313 4 Description page 43313 2 Specifications page 43313 3 Schneider Electric 0 E 10 30 V 250 3 wire detector connection and encoder supply 10 30 V Capture input 0 2 wire detector connection and encoder supply 5V 43313 EN FM 5 Description Micro automation platform specifications Process power supply units and modules TBX SUP 10 and TSX SUP 1ee1 power supply units and modules are designed to provide 24 V power to control system peripherals sensors preactuators encoders MMI terminals regulators indicator lamps pushbuttons pneumatic cylinders mini PLC extension rack etc These supplies are connected to a 100 240 V 50 60 400HZ a c supply or 125 V d c supply see characteristics below The power supply provided ranges from 24 W 24 V 1 A to 240 W 24 V 10 A The TSX SUP 1ee1 power supply outputs are safety extra low voltage SELV and can be wired in parallel with a device for optimising the power TSX SUP 1011 1021 models can operate in redundant mode thus ensuring greater availability of safety control systems These power supplies conform to PLC standards IEC 1131 2 for immunity and resistance to interference and EN 50081 2 for radiated interference TSX SUP 1011 1021 1051 process power supply modules These comprise 1 A support plate fo
205. re reliable safer more compact and more cost effective Application developments requiring safety systems and PLC diagnostics Module TSX DPZ 10D2A is suitable for emergency stop and limit switch monitoring applications requiring a level of safety up to category 3 1 according to EN 954 1 safety related parts of control systems 1 For more information on control system safety categories please consult our specialist catalogue Emergency stop monitoring module TSX DPZ 10D2A comprises 1 A metal casing with a locking system for fixing the module in its slot This system is only accessible when the screw terminal block is removed 2 Aremovable screw terminal block for connecting sensors and preactuators 3 A cover giving access to the screw terminal block which also holds the marker legend Connections page 43307 5 Schneider Electric Operation Micro automation platform TSX DPZ safety module Safety module TSX DPZ 10D2A provides the following functions m Monitoring of 1 to 4 dual or single normally closed contacts in pushbuttons emergency stops or limit switches on safety guards for an emergency stop or immediate safety stop system category O emergency stop conforming to EN 418 m Hard wired safety module identical to Preventa safety module XPS 2 N O safety output circuits category 3 Safety module independent of the Micro PLC processor the PLC does not affect the safety module 10 LEDs on the Micro PLC
206. reset 208 106 O 1 Encoder ICaptO Read 2 TSX TAP S15 05 24 connector i Ghanei TSX TAP S15 05 TSX TAP S15 24 105 O 1 IB 7 NC 1 NC 7 NC IValo Enable 2 Sup Ret 8 IB 5V 2 NC 8 IB 24V 205 3 1IZ4 5V 9 NC 3 1Z2 24V 9 NC A _ A A 104 4 4 12 10 OV 4 NC 10 OV Preset 5 IA 5V 11 NC 5 IA 24V 11 NC AGED a 6 IA 12 5V 6 NC 12 4 10 30V CCU CL E AA 3 Cable with connectors TSX CCP H15 4 TSX CAP H15 connector 5 Cable with connectors TSX CDPee1 6 Ribbon or cable with connectors TSX CDPee2 or TSX CDP ee3 TSX TAP S15 ee I oO N Y Sl n Mounting through enclosure dust and damp proof cut out 37 panel with 5 mm maximum Specifications References page 43054 4 page 43054 5 Schneider Electric 43054 EN FM 7 Presentation Micro automation platform description TSX CTZ 1B absolute encoder operation positioning module The 1 channel TSX CTZ 1B positioning module completes the Micro platform range in the counting and positioning field through the acquisition of information from a SSI series absolute encoder This type of module allows for the following and actual positioning of a moving object including after a loss of power This characteristic linked to the absolute encoder is used to simplify the installation of positioning applications It also simplifies the input interfaces by suppressing homing adjustment etc functions Depending on the model the Micro PLCs can r
207. rom several SMC modules into a single Premium module when using modules with 64 channels for example Emegistrer ur Enregistrer sous Exporter Importer Exporter l application Importer une application Convertir Application Orph e Application PL72 Application PL73 Impnmer GFP Configuration de l impression Quitter Ctr Q 1 Cuve stx 2 C PL7USER Essai57 stx Pr t oca sr ovr TZ Program conversion The SMC sequential program conversion can be carried out on the entire program or on a selected part of the program The result of the conversion is a PL7 format source file which can be imported into any task written in Ladder language Once an analysis phase is completed the software offers default correspondence and requests additional information when necessary suc Convertisseur SMC APPLI_LO Programme Wariables Conf Cible Associations S quences 1 s lectionn es A conversion report provides the following information S6 1R430 4R431 4R425 B3 e Result of the conversion for each instruction with the S7 1R491 4R507 B2 1R492 1R493 1R494 R 480 R481 R502 R503 R504 ca cause of non conversion if applicable e List of variable correspondence before and after conversion including I O reassignment Fichier r sultat PL7 Tout S lectionner APPLI_LO LD Analyser R pertoires Parcourir CAASAWUSERIPL7S Fermer This software extension conforms to SMC PLC applicat
208. rors fo Receive Buffer Errors 0 Transmit Statistics The communication diagnostics function is a predefined secure function accessed using a password which allows real time display from a standard browser Transmit Buffer Errors Silo Underlow Late Collision Lost Carrier Transmit Retries Reset counters Adesse de d pat 7 Type de donn e E Fame Hl Data Editor function access to the PLC data and variables Noni or Nest Y ER Arve The access to the variables function is a predefined and secure function accessible Etat d by password allowing the creation of an events table to access the list of PLC variables in read or write The variables to be displayed can be entered and displayed as m Address MW99 for the TSX ETZ 410 module m Symbol S_Pump 234 or address MW99 for the TSX ETZ 510 module In order to be able to write a value in a variable you will need to enter and confirm a second password The animation tables created by the operator can be saved in the Ethernet TSX ETZ 410 510 module La liste des variables n est pas disponible Impossible de rechercher les variables Schneider Electric 43312 EN FM 7 Functions continued e ox cu Copy Paste Layout Options Done Indicator Light Direct Output Station a 50 4 Horizontal Selector Vertical Selector Motor Contro
209. rs on rising or falling edge The number of encoder data bits can be configured with m The modulo function limits the dynamic of the position value to a number of points defined by the modulo parameter value The modulo passage causes an EVti activation event for the event task m The reduction function is used to reduce the position value supplied by the absolute encoder Two offset functions for the position measure are available m Correction function for the encoder offset on the zero mechanical position m Position measure adjustment function corresponds to the position value adjustment more or less The checks are of the following type m Detecting the encoder feedback voltage m Checking the encoder link m Parity check Connections page 43313 5 43313 EN FM 3 References Micro automation platform TSX CTZ 1B absolute encoder positioning module Input type Specifications Channel Reference Weight number 7 kg l Parallel or Acquisition of 200 1000 kHz 1 TSX CTZ 1B 0 205 serial absolute SSI encoder 2 5V 10 30 V Connection accessories TSX CTZ 1B Designation Connection Connector on Add Reference Weight TSX CTZ 1B module 3 kg SUB D Absolute SSI encoder 9 pin SUB D type 3 TSX CAP S9 0 050 connectors batch of 2 Capture inputs High density 15 pin 4 TSX CAP H15 0 050 encoder supply SUB D type Telefast 2 Capture inputs 9 pin SUB D type ABE 7CPA01 0 300 connection encoder
210. s Physical interface Programming port Integrated link PCMCIA card RS PCMCIA card PCMCIA card RS 485 non isolated to TSX SCY 21601 485 isolated RS 422 20 mA CL RS 232 D non TER AUX module isolated RS 485 isolated Link Multidrop Point to point Method of access Master Slave principle Transmission Mode Asynchronous transmission in baseband Medium Shielded double twisted pair Configuration Number 5 devices max 28 devices 16 devices max 2 devices 8 datalink 96 datalink addresses maximum 1 device can occupy several datalink addresses Length of bus 10 m max 1000 m 1000 m max excluding tap links 15 m unlimited via Services Uni TE Point to point requests with confirmation question response of up to 240 bytes 7 initiated by any connected device Unsolicited point to point data without confirmation of up to 240 bytes 7 initiated by any connected device Broadcast messages of up to 240 bytes 7 initiated by the master device Other functions Transparent communication via the master with any device in an X Way architecture Diagnostics debugging adjustment and programming of PLCs Security Check character on each frame acknowledgement and if required repetition of messages ensure security of transmission Monitoring Bus status table transmission error counters and device status can be accessed by program in each device Status of bus and connected devices accessed from the master PLC using PL7 or SYSDIAG software on an F
211. s Master Slave 1 1 2 19 2 Kbps Double shielded twisted pair 5 with Uni Telway 28 with Modbus 10 m for non isolated RS 485 1300 m without tap links for isolated RS 485 1 maximum Uni Telway Uni TE 128 bytes msg handling server Client Server 128 bytes application to application Alldevices on an X Way architecture transparent via the master Master Slave Modbus 7 RTU Read write bits and words Diagnostic TSX 37 05 08 10 PLC TSX 37 21 22 PLC bases bases Uni Telway Modbus Master Slave 7 integrated link 43050 13 Open industrial fieldbus conforming to AS i standard Character mode Uni Telway Modbus AS i RS 232 D RS 485 isolated 20 mA CL AS i standard Master Slave Master Slave 0 6 19 2 Kops 1 2 19 2 Kbps 167 Kbps 2 wire AS i cable Point to point 28 16 31 sensor actuator devices 15m 1000 m 1300 m 100 m 200 m with repeater 1 maximum 1 maximum Uni Telway Transparency of exchanges with sensor actuator Uni TE 240 bytes msg handling server devices Client Server 240 bytes application to application All devices on an X Way architecture transparent via the Modbus master Modbus Master Slave RTU ou ASCII 13 Modbus functions TSX 37 21 22 PLC bases TSX 37 10 21 22 PLC bases Type III PCMCIA card Module to be inserted in slot 4 43594 6 43595 3 and 43596 3 42718 3 1 Modbus Slave only with TSX 37 05 08 2 TER port common with programming and adjustment t
212. s setpoint threshold etc m Conversion of 0 10 V inputs to 0 20 mA or 4 20 mA inputs m Conversion of 8 0 10 V inputs to 8 24 V discrete inputs 1 A 15 pin SUB D type connector for connecting the analogue sensors pre actuators or mounting the TSX ACZ 03 adaptor 2 A 15 way SUB D type connector for connecting the analog sensors preactuators or the discrete sensors 3 Potentiometers for adjusting the first 4 input channels Connection principle for integrated analog channels using the Telefast 2 pre wired system t TSX 37 22 TSX CCP S15j2 ABE 7CPA01 43053 EN FM 2 ATV TSX CDP 611 oo The Telefast 2 pre wired system facilitates installation of modules by providing access to inputs via screw terminal blocks Connection is via a TSX CCP 15 eee shielded cable length 0 5 a 2 5 m fitted with SUB D type connectors at each end The ABE 7CPA01 wiring connection base is used to connect the following m 8 analog inputs or 8 24 V discrete inputs with TSX ACZ 03 adaptor module m 1 analog output m 1 10 V reference output for using 4 external potentiometers for the last 4 channels 4 7 kQ precision 20 maximum if required A female 9 contact SUB D type connector enables direct connection of the speed reference for an Altivar 16 type variable speed controller Schneider Electric Functions Schneider Electric Micro Automat
213. s format The editor provides help with entering data 1 With Premium PLCs only Schneider Electric Functions C blage r Etat Entr es Entr es Sorties JE E la ES TT Sorties Entr es Sorties Non instanci non connect HE Interface et variables publiques E Variables priv es E Fiche Descriptive Code Characteristics References pages 43100 13 to 43100 15 page 43100 17 Schneider Electric Micro Automation Platform PL7 Micro Junior Pro programming software PL7 Pro software offers the user the possibility for Premium PLCs of creating their own function blocks which meet the particular needs of their applications Once they have been created in the library these function blocks can be used with PL7 Junior Pro software These user function blocks enable an application to be structured They are used as soon as a program sequence is repeated several times in the application or to freeze a standard type of programming They can be exported to all other PL7 applications Using a DFB function block in one or more applications enables m Simplification of program entry and design m Improved program readability m Easier debugging all variables handled by the DFB function block are identified on its interface m Use of DFB specific internal variables independent
214. shielded twisted pair RS 485 cables 200 m TSX CSA 200 10 920 500 m TSX CSA 500 30 000 Cables for TSX SCP 114 card TSX SCA 50 T jun box 3 m TSX SCP CU 4030 0 160 isolated RS 485 tap link TSX SCA 62 sub sock 3 m TSX SCP CU 4530 0 180 TSX SCY 21601 TSX SCA 50 T jun box 3m TSX SCY CU 6030 0 180 integrated channel channel 0 TSX SCA 62 sub sock 3 m TSX SCY CU 6530 0 200 Cables for non Micro Premium port TSX P ACC 01 AUX 2m T FTX CB1 020 0 180 isolated PCX 57 TER or AUX box RS 485 tap link 5m T FTX CB1 050 0 420 Micro Premium PCX 57 9 way SUB D 3m 7 TSX PCU 1031 0 140 port or TSX P ACC 01 RS 232 D port for connection box PC compatible TER or AUX Other RS 232D See page 43596 3 and 20 mA CL connecting cables 1 TSX PCU 1031 cable for use with terminal equipped with PL7 software V 4 0 reference TLX eee PL7 e P 40M For PL7 software V lt 4 0 use cable TSX PCU 1030 Characteristics page 43594 2 Schneider Electric MY Modicon _ 43594 FR_EN FM 7 Presentation description Micro automation platform Asynchronous serial links characteristics Micro Premium PLCs provide via their processor coprocessor or TSX SCY 21601 communication module several possible ways for exchanging data in character mode with devices equipped with an asynchronous serial link interface e RS 485 integrated port e Type Ill PCMCIA card with RS 232 D RS 485 RS 422 compatible or 20 mA current loop link Protocols s
215. single length internal words double length floating E KWi KDi KFi single length constant words double length floating lWi j YQWi j module I O words SWIi 128 system words NWi common words on the network MBi L KBi L character string 1 j function block words 1 MWIi indexed objects I O bits constant internal words Structured objects E Mi L bits string I O internal and Grafcet bits E ppi L constant internal words single or double length floating and words system E pBi L character string internal words and constants 1 Function requiring PL7 Junior Pro software 2 If the maximum number of objects are not specified in this table see page 43511 5 3 1024 step bits and macro step step bits 43100 EN FM 15 Selection Micro Automation Platform references PL7 Micro Junior Pro programming software The selection table shown below can be used to define the most suitable programming software in terms of services that are required and the Micro Premium automation platforms used Utilities functions Programming software Languages PL7 Micro PL7 Junior PL7 Pro Instruction List Micro Micro Premium Micro Premium Ladder language Micro Micro Premium Micro Premium Grafcet Micro Micro Premium Micro Premium Grafcet macro steps Premium Premium Structured Text Micro Micro Premium Micro Premium DFB function blocks Creation Premium Operation Premium Premium Display Premium Premium F
216. solution Output load Maximum error at 25 C at 60 C Type of protection Maximum voltage without damage Maximum temperature drift Isolation Betw chann and bus Betw chann and earth Betw channels Consumption Schneider Electric TSX ASZ 401 TSX ASZ 200 4 2 ae T ee bis tivsign n 1 ps 000 E AN AA TT lt 08 0 50 0 57 0 58 0 83 Permanent shota Perm pn rc 30 0 083 0 107 1000 1500 Las Common point See page 43311 2 1 Cut off frequency 10 8 kHz temperature probes 255 Hz high level 2 Precise measurements are given as a function of measurement M for 4 wire temperature probe cabling 3 Ext c with external cold junction compensation Int c with internal cold junction compensation 43053 EN FM 5 Specifications continued Micro Automation Platform Integrated analog channels and analog I O modules A ra j cl lal Integrated in the Type of input modules TSX AMZ 600 TSX 37 22 Number of channels 4 8 Input ranges 10V 0 10 V 0 10 V 0 20 mA 4 20 mA 1 Analog digital conversion 11 sign 11 11 11 from O to 8 20 mA Resolution 6 MV 3800 pts 6 mV 1900 pts 12 pA 1900 pts 12 pA 1500 pts Acquisition period Normal cycle ms 16 32 Fast cycle ms 4 x No of channels used Measurement filtering Digital of the first order with 6 filtering values Hardware filtering 1st order Cut off freq 33 Hz Cut off freq 600 Hz Current Maximum error at 25 C FS 0 16 16 mV
217. stants m 20 Kwords for TSX 37 21 22 shared for example as 4 Kwords of application data and 16 Kwords of the program and its constants Application in the internal Flash EPROM The total volume is equal to the application volume in RAM limited to 11 Kwords or 15 Kwords to which the backup of the first 1024 data words MW is added Application in the PCMCIA card The PCMCIA memory card contains the program and the constants The storage zone for 128 Kword files available according to the PCMCIA card model can be used for distributed applications for storing information which can be consulted remotely via Modem This zone can also be used for storing manufacturing recipes Internal RAM data The data zone can be extended to 17 5 Kwords and is only held in the PLC internal RAM Data backup The first 1024 words are backed up by the PLC internal Flash EPROM memory PL7 Micro Junior Pro software aids the application designer in the management of the structure and the occupation of memory space for Micro PLCs Application protection Whatever the PLC s memory structure is application in internal RAM or on the PCMCIA card it is possible to protect the structure to prohibit access reading or program modification in online mode using PL7 Micro Junior Pro software Backup application Micro TSX 37 21 22 PLCs make it possible to save the 32 K words maximum application programs and constants on a Backup TSX MFP BAK 032P memory card
218. storage kg RAM memory PLCs 32 Kwords TSX MRP 032P 0 030 TSX 37 21 22 64 Kwords TSX MRP 064P 0 030 Flash EPROM PLCs 32 Kwords TSX MFP 032P 0 025 Memory TSX 37 21 22 64 Kwords TSX MFP 064P 0 025 Backup PLCs 32 Kwords TSX MFP BAK 032P 0 025 card 7 TSX 37 21 22 ee Extension for application memory and file storage in RAM memory These cartridges are used for distributed applications as well as for storing information which can be consulted remotely via Modem They can also be used to store manufacturing recipes RAM memory TSX 37 21 22 32 Kwords 128 Kwords TSX MRP 232P 0 060 64 Kwords 128 Kwords TSX MRP 264P 0 060 Flash memory TSX 37 21 22 32 Kwords 128 Kwords TSX MFP 232P 0 060 EPROM TSX PMX PCX Premium 64 Kwords 128 Kwords TSX MFP 264P 0 060 Description Power supply Reference Mass kg Fan modules 24V TSX FAN D2P 0 500 2 y 100 120 V TSX FAN A4P 0 500 y 200 240 V TSX FAN A5P 0 500 Description Use Unit Weight Mass kg Program Simplifies duplication updating or backup TSX PRG LDR 0 150 loader with of 15 Kwords applications program and terminal port constants in internal RAM conn cable length 0 3 m Connection Discrete I O See page 43051 10 accessories Discrete I O with Telefast 2 See pages 14025 2 and 14025 3 Integrated analog I O See page 43051 10 Integrated counter channels See page 43053 5 Backup TSX 37 05 08 10 21 22 TSX PLP 01 0 030 batteries internal RAM Pack of 10
219. supply base Telefast 2 Absolute encoder with High density 15 pin ABE 7CPA11 0 300 adaptation parallel outputs 16 to SUB D type base 24 bits 5 V 10 30 V Cable equipped with SUB D type connectors Designation From To Add Reference Weight 3 kg Cable TSX CTZ 1B module ABE 7CPA01 base 5 TSX CCP H15 0 300 length 2 5 m encoder supply and 15 pin SUB D type 0 205 mm2 capture inputs connector section high density 15 pin SUB D type 1 Product supplied with multi lingual service instructions French and English 2 Absolute encoder with parallel outputs and ABE 7CPA11 adaptation base This base is used to multiplex up to 44 absolute encoders on the encoder input of the TSX CTZ 1B module 3 Addresses see page 43313 5 Description Specifications Connections page 43313 2 page 43313 3 page 43313 5 43313 EN FM 4 Modicon eleme anique Schneider Electric Connections positioning module Micro automation platform TSX CTZ 1B absolute encoder Sensor supply connection examples Absolute encoder conection ee Supply gt 44 t 24 V sensors o ola o ojojn x woo E fa N Aja a ABE 7CPA01 O a lolo rojo ojo olmo Ga CA Ga 22 4 3 G a ABE 7CPA11 Serial absolute SSI encoder Absolute encoder with parallel outputs TSX CAP S9 9 pin SUB D type connector TSX CAP H15 high density 15 pin SUB D type connector TSX CCP H15 equipped cable 3 wi
220. t per line on Micro PLC m 999 labels one label per rung E Comments 222 characters per network Instruction List language Combinational list instructions m 999 labels one label per phrase E Comments 222 characters per phrase m LD LDN LDR LDF read bit status direct inverse rising and falling edges m ST STN S R write an output direct inverse set reset m AND ANDN ANDR ANDF AND logic with one bit direct inverse rising and falling edges m OR ORN ORR ORF OR logic with one bit direct inverse rising and falling edges m LD AND OR opening and closing of parentheses 8 levels possible m XOR XORN XORR XORF OR exclusive with one bit E N negation Structured Text language 1 Structured Text statement m 4 types conditional IF conditional iteratives E WHILE REPEAT and repetitive FOR m Loop stops WHILE REPEAT or FOR EXIT E Comments number of comments per phrase not restricted maximum of 256 characters per comment Grafcet language Chart Micro PLC m 96 steps maximum 2 on 8 pages for TSX 37 10 and 128 steps for TSX 37 21 22 m 1024 transitions maximum 2 m 11 elements maximum per divergence convergence 1 Function requiring PL7 Junior Pro software Ladder language graphic symbols m Open closed and edge contacts E Direct inverse SET RESET coils m Program jump subroutine call coils E Comparison or operation blocks Instructions on the
221. t reverse polarity By reverse mounted diode on power supply Provide 1 fast blow fuse on the 24 V of the preactuator supply Against short circuits By current limiter and thermal breaker and overloads 0 75 lt ld lt 2 2 outputs max See page 43311 2 Paralleling of outputs Consumption Nominal dissipated power 93 Consumption See page 43311 2 Via module 3 5 5 3 2 Via channel at 1 0 15 Isolation Betw outputs and Vrms 1500 50 60 Hz for 1 min ground Test Betw outputs and internal V rms 1500 50 60 Hz for 1 min log voltage Insulation resistance gt 10 at 500 V Module type TSX DSZ 04T22 TSX DMZ 16DTK TSX DMZ 64DTK Connection _ Screw terminal block HE 10 connector cage terminal HE 10 connector block Nominal Voltage 24 EEE output Current AC values Tungsten filament lamp 1 2 max Limit Voltage 19 30 possible up to 34 V limited to 1 hour per 24 hours output Current 25 0 625 0 125 values for U 30 or 34 V Logic Positive current source Leakage current at state 0 lt 0 5 lt 0 5 lt 2 for accidental lt 0 1 disconnection of the 0 V module Residual voltage lt 0 8 forl 2 A lt 0 3 for 500 mA lt 1 5 Min load impedance o p f E Response From state 1 ms lt l PK OB lt 025 time 2 From state 0 ms eto OB 0 25 Switching frequency on inductive an lt 0 5 L12 lt 0 6 LI2 lt 0 5 L12 load Built in Against overvoltages By Zener diode protection Against reverse polarity e By reverse moun
222. tate 1 without tripping Note e Base supplied in a c 24 V process power supply must be used for the mini extension rack when this supports analogue I O modules and relay output modules e Base supplied in d c providing 24 V voltage for the mini extension rack even if this supports analogue I O modules and relay output modules For configurations near the limit it is however necessary to establish the power consumption using the table below Reference Format Nominal currents consumed in mA 1 1 2 half Voltage 5 V Voltage 24 VR Voltage 24 V 2 S standard Module Module Module Discrete inputs TSX DEZ 12D2K_ 1 2 20 76104 TSX DEZ32D2 S jo f 170 254 TSX DEZ 12D2 _ 1 2 jo eee positive logic inputs 87 123 negative logic inputs 83 107 TSX DEZ 08A4 1 2 es ee PF TSX DEZ 08A5 1 2 llo Discrete outputs TSX DSZ 08T2K_ 1 2 po 656 y O 35 38 Oooo TSX DSZ 08T2_ 1 2 Jrs 3588 TSX DSZ 32T2__S 106146 7a y C TSX DSZ 04T22 1 2 Jo CGE CE TSX DSZ 08R5_ 1 2 pasa 5585 TSX DSZ 32R5 S aso gt pp 11514735 120 175 Discrete I O TSX DMZ 16DTK 1 2 46 56 o PF TSX DMZ 28DTK_S 5668 tomnm3sgaop TSX DMZ 28DT__S 5668 o Ooz TSX DMZ 28DR__S po a positive logic inputs 106 160 negative logic inputs 95 131 TSX DMZ 28AR S 40 85 125 TSX DMZ 64DTK S we 147 197 Safety module TSX DPZ 10D2A 1 2 20 Analogue I O TS
223. ted analog channels and analog I O modules TSX AEZ ASZ AMZ analog I O modules TSX ACZ 03 Micro PLCs provide three ways of performing analog processing m With input half format TSX AEZ eee modules and TSX ASZ eee analog outputs modules and TSX AMZ 600 analog I O installed in the available slots base or mini extension rack m Or by using the analog I O integrated into TSX 37 22 PLC bases m Or by using Nano remote analog I O extension modules see pages 43056 3 and 40055 3 m The maximum number of analog modules in a Micro PLC configuration is m 2 fora TSX 37 05 08 10 configuration m 4 fora TSX 37 21 22 configuration 2 TSX ASZ 200 TSX AMZ 600 modules maximum in the base These analog input or output modules are always connected via screw terminal blocks TSX AEZ ASZ AMZ analog I O modules comprise 1 Rigid metal casing 2 Locking system for fixing the module in its slot This system can only be accessed when the screw terminal block is removed 3 Module reference label 4 Connector for fitting screw terminal block Connection equipment supplied with each module 5 TSX BLZ H01 removable screw terminal block for connection of analog sensors and actuators Eight 0 10 V inputs and one 0 10 V output are integrated in TSX 37 22 PLC bases These integrated channels can receive the TSX ACZ 03 adjustment adaptor module which enables m The use of 4 potentiometers for the user to adjust the 4 application constant
224. ted device TSX SCP 114 PCMCIA card for connecting Micro 7 Premium PLCs to the Uni TSX SCY CU 6530 Uni Telway connecting cable between the TSX SCY 21601 module and the TSX SCA 62 subscriber socket 4 connected to the earth of each device 2 installed at the end of the line 3 it is installed at the end of the line 4 the address of the connected device 5 TSX SCA 61 of the connected device 6 7 Telway bus 8 9 TSX PACC 01 connection box used for connecting a Micro Premium PLC to the Uni Telway bus via the PLC terminal port The connecting cable length 1 m is integrated in the connection box It isolates the signals for distances gt 10 m and is used to match the end of line impedance It is also used to set the operation of the terminal port Uni Telway Master Slave or character mode 10XBT Z908 Uni Telway connecting cable between the CCX 17 operator panel and the TSX SCA 62 subscriber socket see page 43583 7 11 TSX SCP CU 4030 Uni Telway connecting cable between the TSX SCP 114 PCMCIA card on TSX P57 0M processor or TSX SCY 21601 module and the TSX SCA 50 junction box 12TSX PCU 1030 1031 Uni Telway connecting cable between the FT 2100 PC compatible and the TER or AUX ports of Micro Premium PLCs or the TSX P ACC 01 connection box 13TSX CSC 015 connecting cable between the TSX 17 micro PLC via a TSX 17 ACC 5 adaptor or a TSX SCG 1161 module and TSX SCA 62 subscriber socket TSX DG UTWE
225. ted diode on power supply Provide 1 fast blow fuse on the 24 V of the preactuator supply Against short circuits By current limiter and electronic By current limiter and thermal By current limiter and electronic and overloads breaker 2 6 lt ld lt 5 breaker 0 75 lt ld lt 2 breaker 0 125 lt ld lt 0 185 Paralleling of outputs a 2 outputs max 2 outputs max 3 outputs max Ww OI 2i al Nominal dissipated power ae nd Per module W 3 8 5 Per channel at 1 W lt 0 7 U 24 V Isolation Betw outputs and ground 1500 50 60 Hz for 1 min Test Betw outputs and internal 1500 50 60 Hz for 1 min log voltage Insulation resistance gt 10 at 500 V 1 Characteristics at 60 C for 60 I O loading or at 30 for 100 I O loading 2 All outputs have fast demagnetisation circuits for electro magnets Discharge time of electro magnets lt L R References Connections pages 43051 9 and 43051 10 pages 43051 11 to 43051 13 Schneider Electric 43051 EN FM 7 Specifications Specifications of relay Module type Number of outputs Operating limit values Type of contact Thermal current a c load Resistive AC 12 duty Inductive AC 14 and AC 15 duty d c load Resistive DC 12 duty Inductive DC 13 duty Voltage Power Voltage Power Voltage Power Voltage L R 60 ms Power Response Activation time Deactivation Built in Against short circuits protection and overloads Against i
226. th In this case attach an 8 pin RJ 45 connector category 5 to the end of the free wire TSX ETZ 410 510 modules Assembly on profiled AM1 DE200 or AM1 DP200 or on AM1 PA mounting plate 150 98 55 116 7 34 63 143 7 1 132 7 2 39 83 1 136 2 mm with profiled AM1 DP200 2 Assembly on AM1 PA mounting plate Schneider Electric 43312 EN FM 11 Presentation References page 48190 7 48190 EN FM 2 Micro automation platform Ethernet TCP IP network connection by 10baseT 100baseTX interface As part of its Transparent Factory family of products Schneider Electric offers a range of industrially hardened network hubs switches transceivers bridges and cables These Ethernet standard communication components enable you to integrate Ethernet solutions from the device level to the control network and beyond to the corporate intranet Each product in the Ethernet cabling system is designed with compliance to Ethernet standards and with third party compatibility in mind e Transparent Factory Hubs connect segments to supply shared communication among PLCs TF Hubs are low cost solutions which enable communications with devices such as Momentum I O to Ethernet networks e Transparent Factory Switches segment the application in different zones groups or cells machines The proper placement of switches can increase network performance by relieving network congestion TF switches implement SNMP protocol a
227. the Concept application This direct link requires Concept version 2 1 to be installed on the OFS station 1 Reference page 43105 3 43105 EN fm 2 Functions continued Micro automation platform references OFS data Server software Development of Client applications OFS software has 2 interfaces e OPC Automation interface Particularly suitable for end users and enables the development of OPC Client applications in Visual Basic in Visual Basic under Excel but also in C e OPC Custom interface Used primarily by suppliers of control system or industrial communication products lt enables the development of applications in C in order to access the OFS software OPC Server This interface is more suitable for software development experts so that they can integrate the Client application into their standard products This is more high per formance interface in terms of access time to the data stored in the OPC Server but requires for its programming a good knowledge in C programming OFS software services The various OFS software services enable e Access to the Server in local or remote mode e Access to variables in the form of addresses or symbols e Reading and writing of variables to one or more PLCs present on the communication network connected to the PC supporting the OFS software These variables can be system variables OPC System Group PLC status diagnostics etc internal variables represen
228. the TSX PGR LDR module comprises 1 A cord for connecting to the PLC terminal port 2 Four operation indicator LEDs 3 A W R button which selects the program transfer direction PLC gt module or module PLC A GO button to start the transfer A Write Only switch which prevents PLC gt module transfer A Program Protect switch which protects the PLC application as read only after the transfer on A references Dimensions mounting pages 43050 13 and 43050 14 page 43050 15 W Modicon Schneider Electric E AI Memory structure continuea TSX 37 05 08 10 21 22 without PCMCIA card on Data NB internal S _ i xX E a UONSTants 3 Programs and constants X 1 Kwords int MW 1 Application data 17 5 Kwords maximum 2 Descriptor and executable code for tasks 3 Constant words initial values and configuration TSX 37 21 22 with a PCMCIA card RAM 4 Kwords int MW PCMCIA Program 2 card File storage 4 1 Application data 17 7 Kwords maximum 2 Descriptor and executable codes for task 3 Constant words initial values and configuration 4 According to the PCMCIA card model characteristics pages 43050 11 and 43050 12 Functions pages 43050 6 and 43050 7 Schneider Electric Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Application memory The application memory is divided into memory zones which are physically shared betwee
229. the routing of data and the selection of a path between 2 devices The addressing mechanism enables the transfer of data between products and ensures automatic and totally transparent routing of messages Layer Provides reliable data exchanges on the connected device s connections transport Layer Concerns application programs data exchange and cooperation conventions application m Uni TE industrial message handling system this standard system for all Schneider Group equipment enables read and write access to variables program transfers management of equipment operating modes link and device diagnostics and transmission of unsolicited data COM distributed database set of words shared by several devices and updated cyclically This service is used to exchange data between TSX 17 Micro Premium and TSX PMX model 40 PLCs m Shared table service 2 set of words shared between several Micro and Premium PLCs and updated cyclically m Exchange of periodic data data updated cyclically between the bus manager PLC TSX PMX model 40 April 5000 7000 or Premium and the Agent device This service is available on the Fipio bus see page 43593 2 Application to application communication suitable for data table exchanges m Telegram not available on Micro priority application to application communication for short and priority exchanges m Other services on Ethernet TCP IP services other than X Way are available I O Scanning W
230. this manual describes the operating principles and the architectures of the Uni Telway bus It is required for setting up and installing the Uni Telway bus TSX DR NET E this manual describes the X Way architectures services and address mechanisms It includes the coding of Uni TE requests as well as precautions for connecting earths for the networks It also includes the principles of asynchronous serial transmission 1 With TSX 37 21 22 PLCs References pages 43594 6 and 43594 7 Characteristics page 43594 2 Schneider Electric 43594 FR_EN FM 5 References Description Integrated link on processor Communication module TSX SCY 21601 Type lll PCMCIA cards for PMX PCX Premium processor TSX 37 21 22 PLC or TSX SCY 21601 module Set of X Way drivers for PC compatible Description amp Terminal port ee connection box i TER Premium e e 1 m connecting D 3 cable TSX SCA 50 Passive T junction box gt 2 channel passive subscriber socket RS 232 C RS 485 active adaptor unit Other connection TSX SCA 72 43594 FR_EN FM 6 Terminal port for OS 2 Use Reference Micro automation platform Uni Telway bus Protocol Physical layer PLC Reference Weight 1 kg Uni Telway RS 485 non isolated Micro See page 43050 13 Character mode Modbus Jbus TSX PCX Slave 2 Premium Please consult our specialist catalogue Modbus Jbus 1 isolated
231. ting the PLC words or registers OPC User Group e Use of a notification mechanism which transmits change of state values to the Client Communication between the OPC Server and the PLC is polling or can be on the initiative of the PLC to decrease the flow of exchanges push data e Definition of dead bands for measurement noise filtering floating variables Communication with PLCs The various variables contained in the PLCs are accessed via Uni TE and Modbus protocols using the following e Uni Telway bus and Fipway Uni TE networks on TCP IP as well as ISAway when using a PCX coprocessor e Modbus serial link Modbus Plus and Modbus networks on TCP IP The various corresponding communication drivers are supplied in the OFS software except Modbus Plus driver which is supplied with its PC Modbus Plus card The link with PL7 or PrOWORX variable symbols is created by means of export files for these variables generated by PL7 or ProWORX development software Concept variables are accessed directly with the Concept application In addition the OFS Server dynamically ensures the consistency of data between the Concept databases and OPC Client applications References The OFS offer comprises An OPC Server software compatible with the OPC Data Access 2 0 standard An OPC Server simulator for debugging the application when no PLCs are present A tool for configuring the Server on the PC A example of OPC Client for setting up appli
232. tions connected on different Ethernet TCP IP Fipway Fipio segments of the same multi network architecture 1 Ethway is not available on Micro and TSX 17 20 PLCs 256 bytes for synchronous requests and 1 K byte for requests processed as a background task 2 Size limited to 128 bytes on Micro Premium terminal port TSX PMX 40 models Size limited to 32 bytes on TSX 17 20 and TSX 47 20 25 Schneider Electric W Modicon 43300 EN FM 3 ME PRE PO l Application service Micro Automation Platform continued X WAY communication The COM service available on the Fipway Ethway 7 network consists of a set of dedicated words known as common words NW on Micro Premium PLCs and COM i j kon TSX 17 20 and TSX PMX model 40 PLCs Depending on its software configuration each network station may or may not access the database in read only or read write mode All PLC stations exchanging common words maximum 32 stations are allocated in a dedicated 128 word database a write field which is set at 4 words per Micro Premium station 2 Fipway Ethway fae a mm E o B mae ee a ce aa e m o y 5 o 5 o o 9 o o 9 o E E E 9 lo o 9 9 O o ollo 9 y 3 jo 9 FP 0 ba Flo Mi i a a a A TL NW distributed database 128 words The COM words in a PLC are updated automatically during each scan of the general sequence master task with no intervention by t
233. ton Selection of modules to be inserted in addition to the 16 input 12 output module present at rack no 1 Type of module to be inserted Max number of modules Format Connection 1 2 Standard Half Connector Term blk Discrete Inputs Outputs 8 inputs 12 inputs nl 32 inputs fo IS E 4 outputs E po o 8 outputs 32 outputs 16 inputs outputs 28 inputs outputs 64 inputs outputs Preventa safety module Analogue I O 4 or 8 inputs 2 or 4 outputs 4 inputs and 2 outputs Counter positioning channels 1 incremental code channel 2 incremental code channels 1 absolute encoder channel Insertion possible Functions Characteristics references Dimensions mounting pages 43050 6 and 43050 7 pages 43050 11 and 43050 12 pages 43050 13 and 43050 14 page 43050 15 43050 EN FM 2 Schneider Electric Presentation description selection Micro Automation Platform TSX 37 08 PLCs The TSX 37 08 PLC comprises a rack which integrates 100 240 V power supply a processor including a 11 Kword memory program data and constants 1 Flash EPROM backup memory 2 TSX DMZ 28DR discrete I O modules 16 inputs and 12 relay outputs and an available slot The available slot can accept m 1 standard format discrete I O module of any type m 2 half format discrete I O safety analog I O or counter modules The TSX 37 08 PLC comprises 3 slot rack N Centralized display block oO
234. ts positions 7 to 10 11 LED showing voltage presence of 24 V 12 Power supply terminals protected by removable cover to connect an auxiliary 24 V power supply if PLCs are supplied with 100 240 V 13 Earth terminal 14Connectors to the base PLC 15 Reset button OO JO O A ON Selection of modules to be inserted 5 slots available that is a maximum of 9 positions Type of module to be inserted Discrete Inputs Outputs 8 inputs 12 inputs 32 inputs 4 outputs 8 outputs 32 outputs 16 inputs outputs 28 inputs outputs 64 inputs outputs Preventa safety module AS i bus or I O extension Analog I O 4 or 8 inputs 2 or 4 outputs 2 inputs and 4 outputs Counting 1 or 2 incremental encoder channels positioning 1 absolute encoder channel Communication Uni Telwa PCMCIA card on Serial link processor Modbus Modbus Plus Fipwa Fipio Agent Ethernet TCP IP or external Modem Communication characteristics pages 43050 11 and 43050 12 Functions pages 43050 6 and 43050 7 Schneider Electric Connection Connect Term blk Format Stand Half Maximum number of modules 1 1 3 4 5 9 AAA EY IIA 2 E ee 2 po EY po 3 External module IY Insertion possible 1 With TSX RKZ 02 mini extension rack 2 Comprises a standard format module to be placed in 1st slot of the PLC 3 The remote discrete I O extension modules and AS i b
235. twork kg Fipio Fipway 20 maximum Micro Premium Micro OZD FIP G3 0 500 fibre optic TBX distr I O Premium transceiver with TBX LEP 30 with 1 Momentum distr I O TSX FPP CCX 17 panels 20 version 2 4 PCMCIA FT 2100 FTX 517 card PC compatible Micro Premium PLC connection components 2 Description Use Compo Reference Weight sition kg Fipway card TSX 37 21 22 PLC 1 type Ill TSX FPP 200 0 110 TSX PMX 57 processor PCMCIA PCX 57 coprocessor card Fipio agent TSX 37 21 22 PLC 1 type lll TSX FPP 10 0 110 function TSX PMX 57 processor PCMCIA card PCX 57 coprocessor card 1 For TSX FP ACC 8M fibre optic electrical repeater see page 43597 6 2 For accessories and connecting cables see pages 43597 5 to 4359777 43590 EN FM 3 Presentation Micro automation platform characteristics Uni Telway bus The Uni Telway bus is a standard means of communication between control system HITA components PLCs MMI terminals supervisors variable speed drives numerical a OEA li controllers weighing equipment etc tmi al i E It is suitable for architectures designed to pilot control and monitoring devices via a PLC or architectures used for MMI supervision etc The Uni Telway bus requires a master station which manages the allocation of bus access rights to the various connected stations known as slave stations Uni Telway Structure Type Heterogeneous industrial bu
236. ules connected via connector I O modules with connection via connector comprise 1 A rigid metal casing 2 A locking mechanism for fixing the module in its slot 3 One two or four HE 10 connectors for connection to sensors and preactuators Half format I O module Standard format I O module Discrete I O module connected via connector and cage terminal The TSX DMZ 16DTK module comprises 1 A rigid metal casing 2 A locking mechanism for fixing the module in its slot 3 One HE 10 connector for connection to sensors and preactuators 4 A cage terminal for connecting the input and output power supplies 1 TSX DMZ 28 DTK and TSX DMZ 64 DTK I O modules can also be used in association with Tego Dial and Tego Power systems 2 See pages 15000 2 to 15012 3 Specifications References Connections pages 43051 5 to 43051 8 pages 43051 9 and 43051 10 pages 43051 11 to 43051 13 Schneider Electric MM Modicon__ 43051 EN FM 3 Functions compatibility Specifications pages 43051 5 to 43051 8 43051 EN FM 4 References pages 43051 9 and 43051 10 Micro automation platform Discrete I O modules I O assignment by software configuration specific functions can be assigned to certain inputs The first four inputs of a discrete I O module located in slot 1 of a TSX Micro PLC can be configured as discrete inputs latching inputs event triggered inputs or up down counter inputs Inputs which can be configured as lat
237. unctional views Application Premium Function modules Creation Premium Operation Premium DFB function blocks for application diagnostics Creation Premium Operation Premium Display Premium Diagnostics viewer Premium Runtime screens Creation Micro Premium Application converters PL7 2 Micro Premium Micro Premium Micro Premium Micro Premium Micro Premium Orphee Micro Premium Micro Premium Software extensions SMC converter Micro Premium Micro Premium SDKC C language dev Micro Micro Premium Micro Premium PL7 DIF comparison of PL7 applications EA Premium OFS data server Micro Micro Premium Micro Premium WSBY Warm Standby redundancy WAN Premium Multilingual software packages English French German Spanish and Italian for PC compatibles 1 equipped with Windows 95 Windows 98 Windows NT 4 0 or Windows 2000 Professional operating systems For one station these packages comprise m A CD ROM supporting the PL7 multilingual software the PL7 demonstration applications and the terminal link Uni Telway driver 2 m A cable reference TSX PCU 1031 PC compatible to Micro Premium PLC length 2 5 m Not supplied with software upgrade or update packages m A multilingual PL7 software start up and installation guide m A CD ROM containing multilingual technical documentation m A CD ROM containing the Micro Premium platform operating systems For packages for 3 stations the above quantit
238. upported are character mode ASCII Uni Telway and Modbus Other protocols are also available or can be developed on request on a RS 485 or RS 232 D link which enables Micro Premium PLCs to communicate on third party architectures These products are offered within the framework of the Schneider Alliances partnership programme see page 43614 2 The list of modules available can be obtained from your Regional Sales Office or from our Internet site www schneideralliances com Physical layer Transmission Services References page 43596 3 Integrated links 1 Via integrated port on the processor or coprocessor The AUX 1 port 8 way mini DIN connector has one non isolated RS 485 serial link channel maximum distance 10 m 2 Via integrated port on the TSX SCY 21601 module This module for Premium PLCs has one isolated RS 485 serial link channel 25 way SUB D connector Half duplex multiprotocol including Uni Telway TSX SCP 11e multiprotocol PCMCIA cards 3 A slot on the processor coprocessor and on the TSX SCY 21601 module takes cards which comprise 4 Aremovable cover with fixing screws for access to the 20 way miniature connector 5 Two indicator lamps ERR lamp card or link fault COM lamp data transmission or reception Connector cable to be ordered separately TSX SCP Ce eee cable 1 TER port for Micro TSX 37 05 08 10 PLC Type Non isolated Isolated RS 485 PCMCIA cards RS 485 20 mA current
239. us modules are installed in position 4 which means that their use is mutually exclusive 4 With a maximum of 2 TSX AMZ 600 ASZ 200 modules in the base references pages 43050 13 and 43050 14 Dimensions mounting page 43050 15 43050 EN FM 5 Functions Description pages 43050 2 to 43050 5 43050 EN FM 6 characteristics pages 43050 11 and 43050 12 Micro Automation Platform TSX 37 05 08 10 21 22 PLCs Discrete Inputs Outputs The range of in rack discrete l O modules offers several possibilities for meeting requirements m Cost effective connection where a 24 V solution is required mixed I O modules with HE type 10 connectors for direct connection to pre actuators in the device using cables with flying leads or direct connection to the TELEFAST2 pre wired system m Connection to the screw terminal block on the front panel of mixed I O modules A set of half format modules enable the PLC configuration to be adapted as closely as possible to the user s requirements in terms of number range of I O and type of connection For further details see pages 43051 2 to 43051 13 The TSX DPZ 10D2A Preventa type safety relay module provides a monitoring function for the emergency stop pushbuttons or limit switches and is adapted to conform to the safety requirements stipulated in EN 954 1 For further details see pages 43308 2 to 43307 5 Remote discrete I O extension module TSX 37 10 21 22 Micro PLCS offer two di
240. uses all the functions of the TSX ETZ 410 module and in addition the following functions on the level of the integrated Web server function m Graphic object editor function to assist in creating Web user pages m Configuration tool for the integrated WEB server Integration into structures The Ethernet TSX ETZ 410 510 modules communicate with the Micro TSX 37 10 21 22 PLCs which are equipped with the operating system version IE 2 2 0 They connect m Via the O TSX 37 10 21 22 PLC terminal port TER O TSX 37 21 22 PLC auxiliary port AUX o TSX SCP 114 serial link PCMCIA card inserted into the TSX 37 21 22 PLC m On a Uni Telway bus via the TSX SCA 50 derivation box or the TSX P ACC 01 isolation box The Ethernet TSX ETZ 410 510 modules are configured using m The Ethernet network with the assistance of a standard browser m RS 232 serial link with the assistance of the PC port in hyper terminal mode PPP protocol The Ethernet TSX ETZ 410 510 modules ensure that the Micro PLC TER port is duplicated the PLC connected to the TSX ETZ 410 510 module via this TER port can be accessed locally by a programming terminal equipped with PL7 Micro Junior Pro software using the duplicated port on the front panel of the Ethernet module Schneider Electric Structure Micro automation platform Ethernet network and TCP IP Modem serial link CP IP profile on Ether Summary of the OSI structure OSI model Ethernet TCP IP profi
241. ut module Example of connecting inputs to TSX DMZ 28DR Example of connecting inputs to TSX DMZ 64DTK TSX DMZ 28DR Inputs EESE le 24 V input power supply BREA LJ LJ Inputs l1 5 ic 205 z Bedell NM Inputs l1 4 204 103 Direction 3 9 Ave Channel 1 ES eh Sensors 2020 Chan 0 Counter reset lelle Chan 1 Counter Preset 100 A 101 EE Channel 0 po Q 24 V power supply DEDO 200 1 pe i FU1 0 5 A fast blow fuse ll 4 1 Encoder A 2 Cable with connectors TSX CDPee1 Micro 3 Cable with connectors TSX CDPee2 or TSX CDP e63 2 Specifications References page 43054 4 page 43054 5 Schneider Electric Connections continued Micro automation platform dimensions Integrated counter channels and counter modules Connection to module TSX CTZ 1A 2A 2AA Example of connecting counter inputs E E 24 V counter sensor TELS power supply 1 2 a oft D EEA a E A Telefast 2 3 3 Chan 0 Chan 0 Chan 1 Chan 1 ABE 7CPA01 3 wire proximity sensor PNP Channels O and 1 Example of connecting auxiliary I O Ty _ ogy auxiliary 102 0 2 10 30 V I O power supply 101 o L te 400 0 5V 5 i Telefast 2 lt ICapt1 ms P Read 210 Channel 1 ABE 7H16R20 for 2 channels aii a A a or ABE 7H08R10 for 1 channel 2090 108 o IPres1 P
242. xport in text format txt Animation table Tables containing the application variables to be monitored or modified can be created by entering them or automatically initialized from the selected phrase or rung Variables can then be m Modified m Forced to 0 or 1 for bit objects For each numerical variable it is possible to select the display base decimal binary hexadecimal floating point ASCII message Version gt V4 0 of PL7 offers new options for animation tables m Display of the comment associated with variables m Assignment of a single value to a number of variables m Change of display format for a number of variables m Display of the list of forced bits 43100 EN FM 9 Functions continued M PL7 PRO APP5725F BEE Eichier Edition Services Yue Outs AP Debug Options Fen tre 2 a S ojal amp aleje sa Sm 21217 alejo 2 Y MACHINE_DOSAGE Y Configuration 5 E Configuration mat riete Dg Configuration mat rielle 4 B Configuration des racks 2 B Param tres des coupleurs 2 B Configuration logicielle 1 Vue fonctionnelle Y Programme 23 E Structure application 1 A T che Mast 22 vu Sections 22 E Sequentele 19 fp Remplissage 2 ES Vid_melangew 1 Verit_dib Vider Vid_melangeur Verif_dib Wawa z 1 Ecran d exploitation Pr t ILOCAL USYS er70k_ MODIF OVR BOU ca Ls PRO regbbuc Eceran d exploitation Contr
Download Pdf Manuals
Related Search
Related Contents
Corvair/Rajay Turbocharger Primer Intel R1304GL4DS9 Server User Manual CONSEILS CONSO Image Alchemy v1.10 Addendum UCV 202 - Point commun 2 Manual do Utilizador do Auricular Bluetooth Nokia Reaction 取扱説明書 - Panasonic Samsung AVXTJH028EE User Manual EZ:faast User Guide Lire l`article Copyright © All rights reserved.