03_hyundai_fan_coil_unit_(48pages)

image

Contents

1. lt Rotary switch inner connection gt 4 Company x Rotary switch inner connection JOM BUadSs i lt km A Ceiling Switch Assembly Diagram Micom Switch IR receiver Oo C Auto auto oat lei DDA high S W Panel worker O DA medium Oe low OO Power ay J Temp control Air flow rate worker power Motor low Motor medium Motor high Motor common As a unit separate from the standard parts fan coil wal unit and a switch box buried in the field to suitable location please Provide a worker to install the switch box MAIN power Temperature sensors 41 Drain Hose Installation and Construction of Drainage Pipes m Now with the following installation of drain hose m See below for the construction of drainage pipes air intake pipe Condensate water of drain pump that can help prevent the reversal OD 16mm access Piping specification is large sealing tape and wrapped in access door after mounting securely fastened to the pipes do Drain hose 600mm Individual drainage piping And natural drainage must be the boat to be lowered to Direction Taping adhesive should handle piping access QF 600mm Plumbing and Drainage And natural drainage must be the boat to be lowered to Direction Please install the air inlet should probably also 300mm within lt Cautions before installation gt 1 Fix each connecti
2. FAN COIL UNIT For Well Being Life A specialized manufacturer for Fan Coil Unit and Ventilation Unit ih HYUNDAI CLIMATE CONTROL CO LTD M NO Technologies for cooling and heating ventilation system leading digital age HYUNDAI CLIMATE CONTROL CO LTD is a major leading company for markets CONTENTS Major features for fan coil unit 08 1 way ceiling cassette slim type 10 4 way ceiling cassette type 12 2 way ceiling cassette type 14 1 way ceiling cassette type 16 Ceiling cassette type 18 Floor exposed Slant discharge type Floor concealed Slant discharge type 20 Floor exposed Top discharge type Floor concealed Top discharge type 22 Floor exposed Front discharge type Floor concealed Front discharge type 24 Floor concealed Front inhalation type 26 Lowboy exposed type Lowboy concealed type 28 Ceiling exposed type Ceiling concealed type 30 High pressure ceiling concealed type 32 Vertical type front discharge top duct 34 Large temperature differential type fan coil unit 36 Standard electrical wiring diagram 40 Product installation diagram 43 Cooling Heating Performance Data 44 User manual 47 HYUNDAI HYUNDAI CLIMATE CONTROL CO LTD iS pursuing for coziness even in what you can t see 2 WAY CEILING CASSETTE TYPE 4 WAY CEILING CASSETTE TYPE CEILING CASSETTE TYPE L l FLOOR CONCEALED TOP DISCHARGE TYPE FLOOR EXPOSED TOP DISCHARGE TYPE
3. 14 17 5 IS 23 a note Based on the ceiling is 3m high reinforced concrete building Transportation Loading After unwrapping the packing How to install Pipe construction Electrical wiring Cautions for operation How to handle User manual Transport the product griped by two people at both end and be careful not to drop it or make it collide with others during transportation otherwise it may cause damage of the equipment When you heap the product up on the site do not heap it up to 6 steps without unpacking it When you heap it up outdoor pack it well with vinyl so that it is not exposed to rain and snow If dust and impurities penetrates into the equipment on the construction site during unpacking installation and operation it may cause the performance to be deteriorated Therefore make sure to cover the upper side Make sure not to use the equipment during construction Otherwise dust is stuck with fan which causes vibration In this case free A S is not available If casing of outer feature is scratched it is impossible to paint it again therefore be careful for handling it Keep the unit horizontal using bolts for adjusting level Secure a space for plugging and unplugging air filter for built into type Longer than 22 cm forward Any barrier shouldn t exist for easy air suction and barriers should be apart from the discharging direction more than 50cm Cle
4. 5 8 390 6 420 10 090 6 690 12 010 6 850 AO 4 1 7 7 510 6 060 9 620 6 420 11 130 6 700 9 6 210 5 370 7 870 5 960 9 790 6 270 Heating Performance Data Unit Kcal h Heated indoor Air Dry Bulb Temperature C SFC 30 SFC 40 SFC 60 SEC 80 SFC 120 8 5 11 3 17 22 6 34 entrance 40 40 4 1 4 1 4 320 5 340 6 350 4 460 5 500 6 540 5 020 6 220 7 410 5 840 7 250 8 660 5 930 7 350 8 760 6 330 7 910 9 490 7 160 8 940 10 720 7 730 9 670 80 12 490 11 970 11 610 60 10 750 10 250 9 740 70 13 230 12 720 12 200 80 15 700 15 180 14 660 40 6 580 6 000 5 410 60 12 540 11 960 11 390 45 8 070 7 490 6 900 14 270 60 12 750 12 120 11 540 80 18 610 17 990 17 370 60 11 640 11 080 10 530 70 14 430 13 870 13 320 40 6 850 6 230 p60 60 13 060 14 450 11 840 40 7 280 6 620 5 960 60 13 870 13 220 12 560 45 8 930 8 270 7 610 17 170 16 510 15 850 50 10 580 9 920 9 260 80 20 520 19 810 19 150 45 oldalas ay HOSPITAL HOTEL i 3 Keep the equipment horizontal by checking if the floor is horizontal and adjusting high and low projection and slope using adjustment bolts When you disassemble exposed typed circuit board for each model it is easily disassembled by lowing the fixed circular bar located in the circuit board For the first operation of the
5. 1 1 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm 2 1 Inlet A 20 25 32 40 40 50 50 Piping Outlet A 20 25 32 40 40 50 50 Drain mm NIPPLE 20A NIPPLE 25A Exterior cold rolling steel t1 0 powder heat and dry coating white beige Lagging sound absorbing materials P U Foam P E Foam flame resistant Air flow rate control Micom switch Auto High Medium Low Micom switch Airflow rate high Electricity single step 220V 60Hz 3g 380V 60Hz Air Filter Vinyl chloride Flush Weight Kg 107 122 145 179 220 300 315 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 s entrance water temperature 5 w heating capacity indoor air 18 entrance water temperature 80r 2 capacity condition B cooling capacity indoor air DB 27 WB 19 5 entrance water temperature 7 gt heating capacity indoor air 21 e entrance water temperature 60 t x Top of duct is required static pressure change the motor output 35 Large Temperature Differential Type Fan Coil Unit 4 WAY CEILING 2 WAY CEILING 1 WAY CEILING HIGH PRESSURE CEILING CASSETTE TYPE CASSETTE TYPE CASSETTE TYPE CONCEALED TYPE ning system by large temperature differential method has benefits as following Approximately more than 10 of cost saving in initial investment flow rate is reduced to 60 compared with conventional system Implementation for low power consumption Approximately 20 of saving of in conditioning
6. 140 Volume flow 10 6 12 8 15 11 5 20 15 7 30 22 4 Head loss 1 5 0 72 2 4 15 4 1 29 1 9 IRS 4 1 Bol Type Double suction turbo type Size g192 x L170 g192 x L200 g192 x L170 g192 x L200 g192 x L200 Fan Air flow rate 5 7 8 5 11 3 17 22 6 Driving Motor connected driving Number 1 1 2 2 3 Type Semi hermetic six pole b type insulation Motor Power consumption 45 55 75 95 55 95W Number 1 1 1 1 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch Bal Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm NIPPLE 3 4 20A Exterior Galvanized steel Lagging sound absorbing materials Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight Kg 52 Note 1 capacity condition A cooling capacity indoor air DB 27 e WB 21 entrance water temperature 5 heating capacity indoor air 18 entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 e WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 t 19 PRODUCT FEATURES With stylish and rounded design its front and side area its color is well harmonized with every interior White Beige exposed type Air flow rate is freely adjustable with 3 stepped rotary switch It uses co
7. 2 WATER INLET PF 3 4 20A BS 1 DRAIN PAN Flush AIR FILTER F F M SIROCCO 1g 220V 60Hz FAN IMPELLER SOFT VINYL E ID g14 0D 18 FAN HOUSING CU AL 1 S187 1035 SLIT FIN GRILLE 120x120 High Medium ROTARY MOTOR HEATRESSTNGABS G CONTROL S W non DRAIN HOSE 1 ACCESS DOOR 120 x200 ABS 2 COATING HEAT amp COOLING COIL EXTERIOR PANEL t1 0 CR 1 16 BASE t3 0 Mixed PP 2 MODEL SFC 20TM T K 30 SFC 30TM SFC 40TM SFC 60TM SFC 80TM SFC 120TM DESCRIPTION DIMENSION MATL QTY REMARK WATER OUTLET PF 3 4 20A BS 1 AIR VENT 3 BS 1 MANUAL 1 2 3 4 PF 3 4 20A BS 3 ee en OO OVH i a145 PLASTIC FLUSH SIROCCO 9 1g 220V 60Hz 10 ID g14 0D g18 u 38 6t035 SOFT VINYL 1 12 CONTROL SW High Medium CUAL 1 Low 3 steps SILT FIN ROTARY Specification Capacitycondtion a B A B A B A 8 A B A B Cooling capacity Kcal h 6 370 4 720 9 320 6 770 8 820 Capacity Heating capacity Kcal h 4 630 9 250 5770 12 500 20 530 I 12 350 Volume flow min 10 15 11 5 40 29 3 Head loss mAq 15 4 1 29 1 9 4 1 pS Type Double suction turbo type Size mm g145 x L165 145 x L200 145 x L165 145 x L200 145 x L200 145 x L200 Fan Air flow rate m min 5 7 8 5 11 3 17 22 6 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Type
8. 8 4 2 25 43 s a Sil ol 22 4 9 ih 1 8 1 1 2 1 ee 3 6 15 4 2 2 4 Type Double suction turbo type SIROCCO FAN Air flow rate m min 13 17 Z 28 31 55 40 45 50 55 Motor connected driving mmAq 5 EA 1 2 2 3 3 3 3 3 3 3 fe Type BLDC MOTOR 2 Power consumption W 92 115 164 198 248 276 340 370 440 470 Number EA 1 2 2 3 3 3 1 1 1 1 zS Type Unite type Multi Pass Cross Finned Tube Slit Fin TS Fin Pitch mm 2 1 Inlet PF 3 4 20A PT 1 25A Outlet A PF 3 4 20A PT 1 25A amp Drain mm NIPPLE PT 3 4 20A Exterior cold rolling steel t1 0 Lagging sound absorbing materials P U Foam P E Foam flame resistant Air flow rate control Micom switch Auto High Medium Low Electricity single step 220V 60Hz Air Filter Vinyl chloride Flush Size ma 490x700 730x700 730x700 1290 x700 1290 x700 1290 x 700 1290 x 700 1290x700 1290x700 1290 x 700 DxWxH x310 x310 x310 x310 x310 x 310 x 360 x 360 x 360 x 360 Weight 58 Note 1 capacity condition A cooling capacity indoor air DB 27 Y WB 21 entrance water temperature 5 heating capacity indoor air 18 Y entrance water temperature 80 Y 2 capacity condition B cooling capacity indoor air DB 27 WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 g 33 VERTICAL TYPE FRONT DISCHARGE 3 A EE se Il I N l s an 3 Jop PRODUCT FEATURES Air f
9. 82 2 2009 3121 2 FAX 82 2 2009 3120 Factory 780 825 Mohwa ri 51 51 Oedong eup Gyeongju Si Gyeongsangbuk Do Rep of KOREA TEL 82 54 745 8661 FAX 82 54 745 8677 http www hdcc co kr e mail hdcc hdcc co kr The contents of this catalog to improve appearance and product performance can be modified without notice No SW20091010
10. A cooling capacity indoor air DB 27 e WB 21 entrance water temperature 5 heating capacity indoor air 18 S entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 e WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 Dimension in is for concealed type 21 EXPOSED CHARGE TYPE R CO DISCt ARGE TYPE PRODUCT FEATURES With stylish and rounded design its front and side area its color is well harmonized with every interior White Beige It is design to be capable of changing into front discharging type for indoor purpose It uses condenser resin mould motor that has long life and low noise It is easy for pipe connection using flexible tubes It uses a simple discharging grill capable of adjusting air flow rate by 90 degree so that indoor air can be uniformly distributed Exposed type Air flow rate is freely selectable with 3 stepped rotary switch High Medium Low Micom wireless remote control switch can be attached Exposed type for additional request 22 FLOOR EXPOSED TOP DISCHARGE TYPE MODEL SFC 20T 940 120 4 480 4 1 1 SFC 30T 1060 5 1 1 SFC 40T 1180 120 6 720 6 1 2 SFC 60T 1420 120 y8 960 8 1 2 SFC 80T 1660 120 10 1200 10 2 3 SFC 120T 1900 12 2 4 P DESCRIPTION DIMENSION MATL QTY REMARK WATER OUTLET INNER SIDE CASING uke GI
11. Ad Rotary Type i 14 ACCESS DOOR 120 200 ABS 15 OUTER AIR PANEL t1 0 CR SFC 120CM DESCRIPTION SLES MATL QTY REMARK WATER OUTLET 1 2 gt MANUAL 3 WATER INLET PF 3 4 20A 4 DRAIN PAN 3 1 5 AIR FILTER VINYLCHLORIDE 1 FLUSH 6 FAN IMPELLER 9145 ABS SIROCCO 7 FAN HOUSING ABS 2j gt 8 A 9 S i MOTOR 14 220V 60Hz ASS Y DRAIN CONNECTION NIPPLE 1 2 15A 1 HEAT amp COOLING COIL 0D3 8 t0 35 CU AL ES EENT Za PAA SFC 20C CM SFC 30C CM SFC 40C CM SFC 60C CM SFC 80C CM SFC 120C CM Capacitycondiion a 68 a B A B A 8 A B A B Cooling capacity Kcal h 2 670 4 730 f 12 020 8 820 Capacity Heating capacity Kcal h 4 630 9 250 A 20 530 12 330 Volume flow i min 10 15 40 29 3 Head loss mAq 1 5 OZ 2 4 le 4 1 LS 18 1 3 4 1 2 4 1 29 Type Double suction turbo type Size mm g145 x L165 g145 x L200 g145 x L165 g145 x L200 g145 x L200 g145 x L200 Fan Air flow rate m min 5 7 8 5 11 3 17 22 6 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Type Semi hermetic six pole b type insulation Motor Power consumption W 40 50 65 80 40 50 80 x 2 Number EA 1 1 1 1 2 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit
12. CASSETTE TYPE PRODUCT FEATURES It is operated by wireless remote control switch and its wind flow rate is adjustable high medium weak and turbo which makes it possible to converted into rapid cooling and heating with strong discharging The wind flow is uniformly discharged in 4 ways front rear left and right direction The main body is built into the ceiling and the rounded grille panel is installed meeting the ceiling space which has no compelling feel and is well harmonized with interiors It uses turbo fan that generates much wind and reduces noise Built in automatic drain pump with head of 600mm from outlet lt is able to connect maximum 16 sets when wired remote control switch is used Discharging air flow is uniform with the added swing function Low power consumption and high efficiency by adopting BLDC motor option 4 WAY CEILING CASSETTE TYPE cA Es D o Lv QO D t J oe D D 2 a N co DESCRIPTION DIMENSION MAT L QTY REMARK DESCRIPTION DIMENSION MATL QTY REMARK 1 INTERIOR GRILLE ASS Y HIPS 1 COLOR WHITE BEIGE GRILLE BUTTON 7 HANGING BRACKET t1 6 Gl 4 ATTACHMENT SNAPS N NG E 8 RECEIVER REMOTE CONTROL Acrylic 1 Wireless remote controller 3 NAME PLATE 1 9 DRAIN JOINT PORT 16 External diameter 1 4 RETURN GRILLE HIPS 1 COLOR WHITE BEIGE 10 COLD HOT WATER OUTLET BS 1 5 AIR GUIDE VANE BSS 14 11 COL
13. DRAIN HOSE ID 14 OD g18 Code Line High Medium 12 CONTROL SW Low 3 steps Specification SFC 20FT FTM SFC 30FT FTM SFC 40FT FTM SFC 60FT FTM SFC 80FT FTM SFC 120FT FTM Capactycondiion A e A 6 A 6 A B A B A B 4720 9 320 6 770 8 820 Capacity Heating capacity Kcal h 4 630 2 980 6 730 4 100 9 250 5 7 12 500 7 530 1310 I 171140 20530 12 350 Volume flow min 10 6 12 8 15 11 5 20 15 7 30 22 4 40 29 3 4 1 is om 24 15 ia 44 27 23 Type Double suction turbo type Size mm g145 x L165 g145 s L200 145 i65 g145 L200 145 L200 145 L200 Fan Air flow rate 5 7 8 5 17 22 6 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Semi hermetic six pole b type insulation Motor Power consumption W 25 35 45 65 40 50 65 x 2 NUMBER EA 1 1 1 2 2 a Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm Z ile Inlet PF 3 4 20A Piping PF 3 4 20A Drain mm Soft vinyl hose ID g14 OD g18 Exterior Exposed type cold rolling steel t1 0 powder heat and dry coating white beige Concealed type galvanized steel t0 8 Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight 47 40 Note 1 capacity condition
14. Fin exchanger Fin Pitch mm 2 1 1 8 Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm NIPPLE 3 4 20A Exterior Exposed Type cold rolling steel t1 0 powder heat and dry coating white beige Concealed Type galvanized steel t0 8 Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight 29140 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 entrance water temperature 5 heating capacity indoor air 18 entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 w WB 19 5 entrance water temperature 7 heating capacity indoor air 21 s entrance water temperature 60 Dimension in is for concealed type 31 32 IGH PRESSURE CEILING CONCEALED TYPE DUCT CONNECTION TYPE PRODUCT FEATURES Heat exchanger and air fan are designed and produced to be compacted in order for comfortable air conditioning to be possible meeting all environments and spaces It is designed to be easily constructed for maintenance job to be easily performed It is easy to be taken in and installed thanks to its light weight and robust design As it is built into the ceiling utilization for indoor space is maximized As the units are able to be installed for each floor the seasonal cooling
15. Semi hermetic six pole b type insulation Motor Power consumption W 25 35 45 65 40 50 65 x2 Number EA 1 1 1 1 2 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm 2il 1 8 Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm Soft vinyl hose ID g14 OD g18 Exterior Exposed Type cold rolling steel t1 0 powder heat and dry coating white beige Concealed Type galvanized steel t0 8 Lagging sound absorbing materials Air flow rate control P U Foam Styrofoam P E Foam Flame resistance High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight 24 14 27 16 31 20 36 25 4 1 32 49 40 Note 1 capacity condition A cooling capacity indoor air DB 27 e WB 21 entrance water temperature 5 s heating capacity indoor air 18 entrance water temperature 80 r 2 capacity condition B cooling capacity indoor air DB 27 e WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 ss Dimension in is for concealed type 23 Ss EXPOSED FRONT Standard Type CEALED FRONT i rr PRODUCT FEATURES Additional case cover is selectable so that it can be harmonized with interior Air flow rate is freely selectable with 3 stepped rotary switch High Medium Low It uses condenser resin mould motor that has long life and low noise
16. for air suction and discharge up to the area for filter gt Make sure to keep the unit horizontal gt Install a discharging duct for built into the ceiling type gt Make sure to secure hole and space 600mm x 600mm for maintenance in filter side gt Secure a space for unplugging the filter 43 44 Cooling Performance Data Unit Kcal h indoor Air Dry Bulb Temperature C indoor Air Wet Bulb Temperature C fi N c 5 1 420 1 160 1 710 1 200 1 870 1 170 4 0 34 i 1 110 5 1 500 10 15 1 430 2 180 1 480 2 390 1 420 9 1 530 1 280 1 950 1 360 2 130 1 320 16 3 5 4 1 640 9 1 550 5 1 730 6 0 72 7 1 680 1 410 2 060 1 510 2 440 1 600 1 340 1 890 1 480 2 220 1 480 12 24 1 730 2 640 1 870 3 170 1 900 9 1 890 1 530 2 380 1 730 2 800 1 760 5 2 200 i aa 7 2 050 9 1 870 5 2 370 g 1 3 7 2 350 1 980 2 930 2 170 3 520 2 210 1 900 2 620 2 020 3 150 2 100 5 2 760 15 4 1 7 2 530 9 2 350 5 3 570 2 790 4 310 2 860 5 190 3 000 50 79 2 560 3 940 2 670 4 670 2 720 9 2 530 5 2 990 10 0 6 7 2 820 9 2 610 5 3 420 15 is 3 130 9 2 920 5 3 670 20 1 9 7 3 420 9 3 110 5 4 660 16 1 4 7 4 350 9 4 140 5 5 420 30 4 1 7 4 970 9 7 450 4 640 5 10 240 5 900 40 7 0 7 9 210 5 340 9 8 170 4 970 5 10 150 6 370 20 12 7 9 110 6 120 9 7 820 5 740 5 11 390 6 790 30 2 4 7 10 360 6 410 9 5 750 4 920 7 300 5 750 9 060 6 110
17. is cooled causing frost in the equipment body Therefore close the valve and stop water ventilation When the heating is stopped for winder and if indoor temperature is below 0 G water in heat exchanger is frozen causing breakage Therefore circulate water by running circulation pump When you don t use the equipment for a long time remove water completely from heat exchanger Do not let hot water temperature exceed 80 C when heating is performed When indoor temperature is low in winder you can acquire normal heat by running the equipment for 1 hour with putting its switch in H High Never put other materials on fan coil unit and sit on them in any case Do not run the equipment during construction Otherwise dust is stuck which cause noise vibration and damage of the motor Make sure to clean air filter when seasons are changing and clean it twice a month during its use gt It is effective to wash them with water in usual temperature using neutral detergent Clean impurities on outer cases with clean and dried clothes do not use benzene gasoline and thinner in any case Clean precipitated impurities in drain fan 17 NDA Head office 630 420 Automotive Parts Innovation Center 210 342 1 Margok dong Buk gu Ulsan Rep of KOREA TEL 82 52 296 0061 2 82 52 219 4647 8 FAX 82 52 296 3100 Seoul office 135 565 Anam Tower Bldg 1116 Yeoksam 1 dong Gangnam gu Seoul Rep of KOREA TEL
18. plastic HIPS ABS material Lagging sound absorbing P U Foam Styrofoam P E Foam Flame resistant Materials Turbo and high medium weak operated by wireless remote control Wire remote control option Air flow rate control Single phase 220V 60Hz Electricity DC 12V Stepping Motor Air Filter Vinyl chloride Flush Motor omm 850 x 576 x 280 Weight mo 8 a a a 30 Note 1 capacity condition A cooling capacity indoor air DB 27 gt WB 21 entrance water temperature 5 t heating capacity indoor air 18 gt entrance water temperature 80 t 2 capacity condition B cooling capacity indoor air DB 27 Y WB 19 5 Y entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 x adopting BLDC motor 17 CEILING CASSETTE TYPE PRODUCT FEATURES f Ma The main body is built into the ceiling and the rounded grill panel is installed meeting the ceiling space which has no compelling feel and is well harmonized with interiors Thanks to its down flow type air distribution is good and discharging air is adjustable tor each season It uses condenser resin mould motor that has long life and low noise The panel is made of aluminum and the air box is made of high density styrofoam weighting lower and the body is adjustable up to 70 mm depending on the height of the ceiling Air flow adjusting switch is additionally provided apart from unit Micom wir
19. transferring power by reducing circulation amount in fan cooling and heating water Approximately 20 of operational and management cost saving Approximately 20 of cost saving for transferring power and electricity Construction cost saving with lower height of the building _ Cooling tower Low temperature refrigerator Building load I Mi j The f imation Wai Pe sa heater tank Pump Heat exchangers Large temperature differential system Large temperature differential system Large temperature differential system using absorbing heating and cooling using ice storage system using local heating water Ih srential temperature based on cooling 8 7 15 Large temperature differential type fan coil unit Heat exchanger and circulating circuit is designed to be suitable for large differential temperature Various indoor equipment can be chosen for size and type of each room 36 HYUNDAI CLIMATE CONTROL CO LTD _ Large temperature differential type fan coil unit Division Model Rating Cooling Rating Heating Air flow Flow Power r a r Capacity Capacity rate rate consumption Motor Model pure kw kcal hr kw kcal hr m min lom w SFC 3K 34l 3 000 55 4 800 13 6 3 80 SFC 4K 4 6 4 000 7 4 6 400 16 8 3 80 Y ae SFC 5K 5 8 5 000 9 3 8 000 19 10 4 80 B g Cassette D SFC 6K 7 0 6 000 11 1 9 600 26 12 5 100 L D SFC 8K 9 3 8 000 14 9 12 800 33
20. uses wireless remote controller to reduce construction cost and improve convenience for consumers and automatic compensation function for power failure and automatic function are added so that wind flow rate can be automatically converted by difference between indoor and desired temperature Wired remote controller can be also used with wireless one simultaneously Fan amp Motor Ass y It uses condenser driving single phase inducing motor that has strong durability In addition it is running very calmly by introducing high quality turbo fan made of ABS and it is designed to select wind flow rates suitable for indoor air conditioning by adjusting RPMs by 4 steps in turbo high medium and low 06 HYUNDAI CLIMATE CONTROL CO LTD FLOOR TYPE Casing Its outfits and colors are well harmonized with the surrounding environments and its noise and condensing is minimized by perfectly attaching heat insulating materials and sound absorbs materials on it Exposed type is hard to be scratched with its separated painting Air Vent It is designed to be easy to controlled in a way that remaining air in coil can be easily discharged to acquire desired air conditioning effects and it is equipped in coil upper side Air Discharge Grile Beautifully equipped Air Discharge Grill is designed to change the direction of wind freely so that discharged air can be uniformly distributed in whole indoor space Coil Water
21. vy FLOOR CONCEALED FRONT DISCHARGE TYPE VERTICAL TYPE FRONT CEILING CONCEALED DISCHARGE TYPE 1 WAY CEILING CASSETTE TYPE FLOOR EXPOSED SLANT DISCHARGE TYPE Ring FLOOR CONCEALED INHALATION TYPE _ LOWBOY EXPOSED TYPE VERTICAL TYPE TOP DUCT i t wm ig HIGH PRESSURE CEILING CONCEALED TYPE CEILING CASSETTE SLIM TYPE og 4 FLOOR CONCEALED SLANT DISCHARGE TYPE FLOOR EXPOSED FRONT DISCHARGE TYPE a ay LOWBOY CONCEALED TYPE CEILING EXPOSED TYPE 1991 1992 1994 1996 1997 2001 2003 2005 2006 2007 10 10 12 12 11 10 HYUNDAI CLIMATE CONTROL CO LTD History HYUNDAI heavy industries climate control facilities dept new establishment Absorption chiller amp Absorption chiller heater technical tie up MHI JAPAN Turbo chiller R 134a technical tie up McCQUAY AMERICA Air Handling Unit AHU technical tie up Dong Yang Factory JAPAN Turbo chiller R 123 technical tie up MHI JAPAN The Foundation to be the law of HYUNDAI climate control Co LTD The registration of international Quality Assurance Standard ISO 9001 Facilities supplier registration of Ice storage system KOREA ELECTRICITY Tubo chiller R 134a distributorship agreement MHI JAPAN GHP EHP distributorship agreement MHI JAPAN Registration for Venture business Technical Innovation Enterprises The registration of internation
22. 0 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 entrance water temperature 5 heating capacity indoor air 18 entrance water temperature 80 gt 2 capacity condition B cooling capacity indoor air DB 27 Y WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 25 N D OANNIF FLOOR CONCEALED FRON PRODUCT FEATURES Additional case cover is selectable so that it can be harmonized with interior it is equipped with a removable filter in front of FCU for preventing interference from tloor clothe hanger in the bottom of the case cover Air flow rate is freely selectable with 3 stepped rotary switch High Medium Low It uses condenser resin mould motor that has long life and low noise Zinc plated steel plate with strong corrosion prooft capability is used for finishing It is easy for pipe connection using flexible tubes FCU can be produced down to minimum 520mm in its height For additional request 26 FLOOR CONCEALED FRONT INHALATION TYPE MODEL SFC 20TFM SFC 30TFM SFC 40TFM SFC 60TFM SFC 80TFM SFC 120TFM 605 Leveling Bolt i Code Line 9 DESCRIPTION DIMENSION MATL QTY REMARK DESCRIPTION DIMENSION MATL QTY REMARK WATER OUTLET PF 3 4 20A 7 FAN IMPELLER 145 ABS F SIROCCO AIR VENT P
23. 0 35 CU AL 1 SLIT FIN 10 CONTROL SW ona V Au 1 ROTARY Low 3steps Specification Section Unit SFC 20L LM SFC 30L LM SFC 40L LM SFC 60L LM SFC 80L LM SFC 120L LM A e A 6 A 8 A 6 A 6 A 8 A B Cooling capacity Kcal h 2 670 4 730 12 020 8 820 Capacity Heating capacity Kcal h 4 630 9 250 20 530 12 330 Volume flow min 10 15 40 29 3 Head loss mAq 1 5 072 24 1 5 4 1 2O is 1 3 4 1 Zal 4 1 2S Type Double suction turbo type Size mm g145 x L165 g145 x L200 g145 x L165 g145 x L200 g145 x L200 g145 x L200 fan Airflow rate min 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Type Semi hermetic six pole b type insulation Motor Power consumption W 25 35 45 65 40 50 65 x 2 Number EA 1 1 1 1 2 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm 2i 1 8 Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm Soft vinyl hose ID g14 OD g18 Exterior Exposed Type cold rolling steel t1 0 powder heat and dry coating white beige Concealed Type galvanized steel t0 8 Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight 49140 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 entrance water temperat
24. 16 7 140 2 WAY SFC2 3K 3 4 3 000 5 5 4 800 11 6 3 36 D D SEEEGLIG SFC2 4K 4 5 3 900 6 7 5 800 13 8 1 48 et 4 WAY SFC1 1K ig 1 500 2 8 2 400 7 3 1 27 Cassette SFC1 2K 3 2 2 800 5 4 300 9 6 38 SFC H132 3 9 3 420 6 1 5 280 13 7 1 92 D D SFC H172 4 4 B70 6 8 5 880 17 iS 115 SFC H212 6 5 5 600 10 1 8 650 21 11 7 164 D High Pressure Ceiling SFC H282 MS 6250 11 4 9 850 28 12 0 198 B Concealed SFC H312 10 3 8 850 15 6 13 380 31 18 4 248 L D F Type SFC H352 115 9 900 17 4 15 000 35 20 6 276 D SFC H402 12 9 11 100 19 8 17 000 40 23 1 340 C SFC H452 14 3 12 300 ZAG 18 600 45 25 6 37 0 SFC H502 16 6 14 280 25 2 21 650 50 29 8 440 SFC H552 17 4 15 000 26 9 23 130 55 31 3 470 m CONTROL h pressure ceiling concealed uct connection type 100 550 _50_ S S Wired remote controller group controlling for 16 sets PC central control Individual control up to 256 sets and group control for 32 sets e Central integrated calculation system 2 or 3 Tey directional control valve ll W2 ire ceiling concealed Type Gi connection type W3 a 37 38 A lt arin E y d A y A LITOV O h GuStomer s mind with the distinctive g high quality of fan coil unit m Micom attached type f
25. 6 850 780 14 0 48 B j 6 1 5 250 9 7 8 400 18 0 92 L lt SFC2 5K 5250 0 LL SFC1 1 5K 1 9 1 600 3 0 2 560 420 5 3 27 D SFC1 2K 2 5 2 100 3 6 3 090 480 7 0 33 c 1 WAY A SFC1 2 5K 2 9 2 500 4 3 3 700 540 9 3 38 SFC1 3K 3 6 3 100 5 1 4 400 540 10 3 38 SFC1 3 5K 4 1 3 500 6 2 5 150 660 11 7 48 SFC S3KB 34 3 000 So 4 500 EE 10 5 9 1 WAY Ceiling SFC S3 5KB 4 3 500 5 9 5 100 11 Tey 11 Cassette Slim Type SFC S4KB 4 5 4 000 7 6 100 15 13 5 15 SFC S4 5KB 5 4 4 800 8 1 7 000 ice 15 esign with base pan cassette type Its whole indoor equipment is strengthened with strong structural design and It is designed to be low noise by completely removing resonance noise from vibration of body CEILING CASSETTE SLIM TYPE PRODUCT FEATURES _ With its structure capable of in taking outer air it is able to suction the constant amount of outer fresh air depending on the construction method of consumers As its indoor equipment is slim it is easy to be installed at lower space ceiling 135mm As the air flows is not directly contacted with the ceiling by the installed engineering projection it prevents the ceiling trom being polluted Registered the patent Built in automatic drain pump with head of 600mm from outlet It is able to connect maximum 16 sets when wired remote control switch is used Discharging air flow is uniform with the added swing function Low power consumption and high efficienc
26. D HOT WATER INLET PF 3 4 20A BS 1 6 SWING MOTOR ASS Y 1 STEPPING MOTOR DC12V 1502 12 DRAIN PUMP PF 3 4 20A 1 1 220V 60Hz x Dimension in is for SFC 10k e SFC 3K SFC 4K SFC 5K SFC 6K SFC 8K SFC 10K Capacity condition Cooling capacity Kcal h f f 5 350 31 50 13 500 10 000 Capacity Heating capacity Kcal h 10 900 10008 a2 s OC Onis 500 Volume flow i 20 14 24 18 29 21 38 27 45 33 3 Head loss l l 3 1 2 8 JJ 2 9 5 35 58 4 9 8 1 Tae Type Single suction turbo type Size 2480 Fan Air flowrate mi mi 16 19 22 26 33 Driving Motor connected driving Number 1 Type Semi hermetic six pole b type insulation Motor Power consumption 110 40 110 40 140 56 140 96 200 130 Number Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch 2 1 1 8 Inlet PF 3 4 20A Piping Outlet PF 3 4 20A Drain 216 external diameter Drain Pump embedded 10W Head 600mm Exterior Body Galvanized steel 0 8t 1 0t grille panel plastic HIPS ABS material Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control Turbo and high medium weak operated by wireless remote control Wire remote contro option Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Discharge grille swing motor DC 12V Stepping Motor Weight 39 0 Note 1 ca
27. F TEMP VALVE central switch DRAIN SWING FAN control contacts Valve PUMP moror CN9 AB AB lt single phose 220V 60Hz gt internal connection color 2A0V 60HZ Usa O O uaall Ped O O pelg UYM O O a operation cold heat wind O O O Display Multi Connection 1 Individual control electrical drawings 7 1 Central control line is connect 1 Central control structure is optional and unlimited connection e ON OFF 2 Central controlling has only ON OFF with the iii connected product and air flow rate is controlled by wired remote control switch where connection is or single contact 220V grouped power cora 3P 3 Multi composing is possible up to maximum 16 sets 4 The power lines have 2 jacks for each product they power ground single contact 220V are same functions bi directional and possible to be multi connected 5 Multi composing is also possible by power line connection between bodies without wired remote controller 2 Individual control electrical drawings 1 Central control line is connect indoor unit 3 Code switch settings example The back of a wired remote control indoor 1 driving indoor 2 driving O 000000000 40 HYUNDAI CLIMATE CONTROL CO LTD Floor Type Connection Ana I aaa Weeds line 2M Black white i V Ground wire green Connection jack 1 2 6 OlQlQ 1265 High Medium Low w White Common
28. Galvanized steel with strong corrosion proof capability is used for finishing It is easy for pipe connection using flexible tubes 24 FLOOR EXPOSED FRONT DISCHARGE TYPE SFC 20F 120 5 600 a E mra a n a a SFC 40F 120 6 720 SFC 60F SFC 80F 120 w 10 1200 120 y8 960 SFC 120F DESCRIPTION WATER OUTLET 120 SHES MAT L ERRO f__A8 tt x 12 1440 QTY REMARK DRAIN PAN ARVET O PT Se INNER AEE OETA CASING he WATER INLET PF 3 4 20A D PLASTIC AIR FILTER VINYL CHLORIDE 1 BLUSH FAN IMPELLER FAN HOUSING g145 SIROCCO MOTOR 1 220V 60Hz DRAIN HOSE ID 14 0Dr 18 SOFT VINYL Ik ip uu y HEAT amp COOLING COIL 3 8 w t0 35 CU AL SLIT FIN ERRER EEHEEHE e 3 a GRILLE HEAT RESISTING ABS 610 ROTARY 120 x 120 CONTROL S W High ue Los 1 ACCESS DOOR PO 200 ABS EXTERIOR PANEL 10 CR 16 BASE 3 0 COMPLEX PP COATING T K 30 a a e a O SFC 20FM SFC 60FM SFC 80FM 1260 1200 SFC 120FM DESCRIPTION DIMENSION MATL QTY REMARK WATER OUTLET PF 3 4 20A AIR VENT PT 1 8 B 1 MANUAL INNER SIDE CASING ull 7 nerra TTT HEHEH eth PLASTIC VINYL CHLORIDE 1 FLUSH TANNA IMPELLE
29. Hz Air Filter Vinyl chloride wash Discharge grille swing motor DC 12V Stepping Motor Weight 3 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 entrance water temperature 5 heating capacity indoor air 18 entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 x adopting BLDC motor 13 1 WAY CEILING CASSETTE TYPE PRODUCT FEATURES With its structure capable of in taking outer air it is able to suction the constant amount of outer fresh air depending on the construction method of consumers It provides calm operation using SIROCCO FAN As its indoor equipment is thin it is easy to be installed at lower space ceiling 235mm As the air flows is not directly contacted with the ceiling by the installed engineering projection it prevents the ceiling from being polluted Registered the patent Built in automatic drain pump head 600mm It is able to connect maximum 16 sets when wired remote control switch is used Discharging air flow is uniform with the added swing function Low power consumption and high efficiency by adopting BLDC motor option 1 WAY CEILING CASSETTE TYPE DESCRIPTION DIMENSION MATL QTY REMARK p 1 INTERIOR GRILLE ASS Y HIPS 1 COLOR WHITE BEIGE S G 2 ER ee HIPS 1 SLIDI
30. NG TYPE 2 3 NAME PLATE 1 f 4 RETURN GRILLE HIS 2 COLOR WHITE BEIGE y 5 AIR GUIDE VANE ASS Y 2 z I 6 HANGING BRACKET Gl 4 re fi N ceiling ceiling DESCRIPTION DIMENSION MATL QTY REMARK Acrylic 4 BLACK WIRELESS 7 RECEIVER REMOTE CONTROL REMOTE CONTROLLER 8 DRAIN JOINT PORT l6 External diameter 1 9 COLD HOT WATER OUTLET PF 3 4 20A 1 10 COLD HOT WATER INLET PF 3 4 20A 1 11 1 1 220V 60Hz 12 DC12V 15 STEPPING MOTOR PA SFC1 1 5K SFC1 2K SFC1 2 5K SFC1 3K SFC1 3 5K Capacity condition A Cooling capacity Kcal h 2 S20 1 a 2 T 2 T 3 zT 2 s 4 I 3 T 4 550 I Capacity Heating capacity Kcal h 4 a 2 5 oe 3 ae 5 780 3 we 7 300 4 500 8 450 5 21010 Volume flow 10 1 13 3 10 3 15 2 11 7 Head loss we a te TE 0 78 ae 2 05 1 24 2 64 1 56 Type Double suction turbo type Size mi4Ox 165 m 40 x 2000 A022002 140 x 200 x 2 140 x 200 x 2 Fan Air flow rate m mi 5 6 7 9 9 11 Driving Motor connected driving Number 1 set Type Semi hermetic six pole b type insulation Motor Power consumption 50 27 50 33 65 38 65 38 65 48 Number 1 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch i Inlet PF 3 4 20A Piping Outlet PF 3 4 20A Drain g16 external diameter Drain Pump embedded 10W head 600mm Exterior Body galvanized steel 0 8t 1 0t grille panel
31. R rr ABS F SIROCCO FAN HOUSING ABS MOTOR 1 8 220V 60Hz ASS Y 10 DRAIN HOSE ID 14 0Dr 418 SOFT VINYL 11 HEAT amp COOLING COL 3 8 x 10 35 CU AL 1 SILT FIN High Medium Loh ffl Salt Fiche oy ans 585 Specification Section Unit SFC 20F FM SFC 30F FM SFC 40F FM SFC 60F FM SFC 80F FM SFC 120F FM paci eio A A Capacity Heating capacity Kcal h 4 630 i 9 250 5 770 12 500 20 530 12 330 Volume flow f min 10 11 5 40 29 3 Head loss mAq 15 4 1 ss Type Double suction turbo type Size mm g145 x L165 g145 x L200 g145 x L165 g145 x L200 g145 x L200 gl45 x L200 Fan Air flow rate m min 5 7 8 5 17 22 6 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Type Semi hermetic six pole b type insulation Motor Power consumption W 25 35 45 65 40 50 65 x 2 Number EA 1 1 1 1 2 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm Bal ile Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm Soft vinyl hose ID g14 OD 18 Exterior Exposed Type cold rolling steel t1 0 powder heat and dry coating white beige Concealed Type galvanized steel t0 8 Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Filter Vinyl chloride Flush Weight 494
32. T 1 8 MANUAL 8 FAN HOUSING ABS F t1 2 9 MOTOR 1g 220V 60Hz ASSY M PF 3 4 20A BS 10 DRAIN HOSE IDg14 OD 918 SOFT VINYL 1 ABS PLASTIC 11 HEAT amp COOLING COIL 0D3 8 x 0 35 CUAL 1 SLITFIN AIR FILTER VINYL CHLORIDE 12 CONTROL SW High Medium Low 3steps 1 ROTARY italiani SFC 20TFM SFC 30TFM SFC 40TFM SFC 60TFM SFC 80TFM SFC 120TFM Capaciycondtion a 6B A e A B A B A B A amp B Cooling capacity Kcal h 2 670 4 730 l 12 020 8 820 Capacity Heating capacity Kcal h 4 630 9 250 20 530 12 330 Volume flow i min 10 15 AO 29 3 Head loss mAq i 0o72 2 4 1 5 4 1 2 9 1 8 1 3 4 1 27 4 1 25 Type Double suction turbo type Size mm g145 x L165 g145 x L200 g145 x L165 g145 x L200 g 145 x L200 g145 x L200 Fan Air flow rate m min 5 7 8 5 11 3 17 22 6 34 Driving Motor connected driving Number EA 1 1 2 2 3 4 Type Semi hermetic six pole b type insulation Motor Power consumption W 25 35 45 65 40 50 65 x 2 Number EA 1 1 1 1 2 2 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch mm 2 1 1 8 Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm Soft vinyl hose ID g14 OD g18 Exterior Galvanized steel t0 8 Lagging sound absorbing materials P U Foam Styrofoam P E Foam Flame resistance Air flow rate control High Medium Low 3 Steps Rotary Switch Electricity Single phase 220V 60Hz Air Fi
33. al Quality Assurance Standard ISO 14001 Movement of Head Office from Gyeondju city to Ulsan city The certification of High Efficiency Energy Facility for Absorption Chiller Heater The certification of ASME for Boiler and Pressure Vessels U S PP The registration of Special Equipment Fabrication for Pressure Vessels and Storage Tanks By Korea Gas Safety Corporation 05 HYUNDAI CLIMATE CONTROL CO LTD is pursuing for coziness even in what you can t see 1 2 4 WAY CEILING CASSETTE TYPE Casing The cases are made so that their colors and outfits are well harmonized with the surrounding and also their heat insulating materials and sound absorbs materials use hard to be flame resistance in order to minimize noise and condensation Automatic Drain Pump p Drain Pump is operated by time control and it is designed to have its maximum head of 600mm Interior Grile Panel Interior Grille Panel is beautifully equipped and it swings 4way Air Guide Vane with angle of 30 70 for ideal air distribution In addition it is designed to be completely closed in order to prevent influx of foreign substance when it is stopped Coil Single body typed circular heat exchanger uses water friendly slit fin whose heat efficiency is maximized and the connection areas for copper pipes and fins used high pressured hydraulic extended pipe method in order to improve heat transferring efficiency Control Switches It
34. an impurities on the floor Lower head of heat exchanger becomes SUPPLY and upper head is DISCHARGE If they are reversely connected poor circulation occurs and frozen breakage may occur Make sure to install manual valve After pipes are constructed keep flexible nuts and pipes warm and insulate heat from them If heat insulation is not perfect condensed water is created which soak the floor Inspect water pressure after pipe construction Remove air in pipes by air ventilation before initiating operation if air is remaining in pipes water is not well ventilated which cause performance deteriorated gt Construct the equipment without its drain hose vent Do not plug air hose at outlet of drain gt As upper installation type and lowboy type are delivered with attached and wired air flow rate switch on them plug the power for operation Check the power As ceiling type additionally provides switches wire it on the site Refer to electrical circuit chart and switch If you want to control multiple fan coil units with a single air flow rate control switch multi and simultaneous operation is possible It is limited to same model air flow rate is not controlled For cooling purpose in window rayed by direct sunlight effective cooling is available by attaching blind and curtain on tt When water ventilation is performed while fan is stopped for a long time for cooling air inside the equipment
35. and heating is easy to be performed depending on the purposes of buildings 6 Taking into account that the system is installed for the ceiling and exposed type the noise is significantly reduced It is designed for consumers to control 3 stepped switch depending on the load HIGH PRESSURE CEILING CONCEALED TYPE DUCT CONNECTION TYPE Wi 100 550 5Q_ ae es te Wes 700 DESCRIPTION WATER OUTLET AIR VENT WATER INLET DRAIN PAN AIR FILTER DRAIN CONNECTION MATL Q TY BS BS BS 1 REMARK PF 3 4 20A Pio PF 3 4 20A Flush BLDC NIPPLE 3 4 20A HEAT amp COOLING COIL 1 Ea aE 1 3 8 x t0 35 SLIT FIN 540 1340 1340 1340 1340 1340 1570 1570 me 490 7a a 1290 1290 1520 1520 W3 330 570 570 1130 1130 1130 1130 1360 1360 H 150 150 150 150 150 150 200 200 200 200 H2 210 210 210 210 210 260 260 H3 310 310 310 310 310 360 360 e Capacity condition A Cooling capacity Kcal h a aT sm sata eth za 5 Heating capacity Kcal h 9 710 5 650 33 100 20 400 38 870 23 400 41 490 25 000 Volume flow l min 17 12 9 185 14 3 28 1 72 4 43 49 3 36 7 55 42 3 59 46 69 5 53 3 75 3 56 7 Head loss mAg 3 2 1
36. e making it easier to be installed even at the low ceiling height with the ceiling matching Indoor decoration well ra 15mm Over Low noise and extremely light weight BLDC motor is used It saves energy cost with its high efficiency and low noise 1mm BLDC fan motor and provides comfortable environment 10 30 of energy cost saving _ Comfortable and Convenient t It is clean with its high capacity and bacteria proof filter j It is easy to be cleaned with removable front grill structure It provides very comfortable cooling and heating system in a way that produces optimized air flow as its smooth swing blades on the ceiling generate winds uniformly wireless and wired remote control functions for making the BLDC motor Conventional AC motor product look more deluxe 08 HYUNDAI CLIMATE CONTROL CO LTD Standard specification for fan coil unit BLDC motor Division Model Rating Cooling Rating Heating Air flow Flow Power No Capacity Capacity rate rate consumption Motor Model kw kcal hr keal nr hr Ipm w SFC 3K 7 3 150 5 050 780 lie 25 SFC 4K 5 0 A 300 6 350 960 14 0 35 i 6 1 5 250 97 8 400 1 140 18 0 AO Rae SFC 5K Cassette See 7 2 6 250 11 6 10 000 1 320 21 0 56 a SFC 8K 9 4 8 150 15 1 13 000 1 560 27 0 96 a SFC 10K 11 6 10 000 18 0 15 500 1 980 Ee 130 N SFC2 3K 3 6 3 150 5 8 5 050 660 11 0 36 m A SFC2 4K 5 0 4 300 7 9
37. eless remote control switch can be attached For additional request CEILING CASSETTE TYPE gt Indoor use and indoor interior and harmony with the inlet air to maintain comfortable indoor conditions was designed for optimal airflow s Horizontal Release heating airflow distribution chart louver angle 40 Strong winds x Vertical release heating airflow distribution chart louver angle 65 Strong winds gt SSS o CEILING CASSETTE TYPE EEE 856 796 530 SFC 20CC 520 x828 SFC 30CC 986 926 660 520x958 SFC 40CC 810 520 x 1108 SFC 60CC 1446 1386 1120 520 x 1418 SFC 80CC len 1600 a 430 0 1728 x Maximum height of drain 255mm DESCRIPTION DIMENSION MATL QTY REMARK 1 BODY SIDE PLATE 2 FAN SIROCCO 3 HEAT amp COOLING COIL JO 035 SILT FIN ADOPT 4 WATER INLET PF 3 4 20A 5 WATER OUTLET PF 3 4 20A 6 AIR VENT PT 1 8 MANUAL 7 DRAIN CONNECTION PT 3 4 20A 8 DRAIN PAN 10 8 COATING W 9 TERMINAL BLOCK 20A 6P 10 GRILLE PANEL COATING 11 SERVICE PANEL t0 8 COATING 12 AIR FLOOR CONTROL GRILLE COATING 13 AIR CHAMBER 14 AIR FILTER VINYL CHLORIDE FLUSH Specification gt SFC 20CC SFC 30CC SFC 40CC SFC 60CC SFC 80CC Capacity condition A B a B A B A B A B 6 770 Capacity Heating capacity Kcal h 4 630 2 980 6 790 4 100 9 250 5 710 12 500 1520 18 310 11
38. equipment remove air in the coil using air ventilation for easy ventilation of water when cooling is switched to heating and vice versa Fan coil unit is basically supposed to cool and heat space using cool and hot water if you use other substance other than water make sure to contact us If you do not run the equipment for a long time prevent frozen breakage by discharging water remaining in the coil If there is no attached automatic valve automatic operation is not available and it may cause frost when cooling is performed Stop water ventilation if you do not use the equipment for more than 4 hours for cooling Frost created in the body motor and grill may cause the life of the product to be shortened Conversion table for cooling and heating area per 1 set F f fi Val Va r a a a CEF Dr i ie 1 gt an On ai gt a Gee o 1 6 T an Sat oh l l 13 16 21 27 28 35 41 50 54 66 80 97 Ges 6 5 8 5 esih FLES GSI 16 0 23 29 2 z 3 INT m EG 12 Zi 2 S 49 66 64 97 1 3 5 5 6 6 5 TEO S 15 20 19 5 29 sS 5 3227 lss 27 44 J 59 f 2 5 4 5 4 5 8 5 6 9 5 8 5 13 5 11 18 21 5 24 m 12 16 16 21 25 35 35 50 50 66 76 86 2 3 5 5 5 6 5 75 1 11 155 15 20 23 26 RESTAURANT m ei Pale 16 2 28 315 32 44 7179 2 5 3 5 4 5 5 5 7 7 10 10 13 SEA CONFERENCE m e 25 33 40 46 57 G76 62 97 ROOM AB eSI5 E e 10 gt 125
39. friendly slit fin whose heat efficiency is maximized and the connection areas for copper pipes and fins used mechanical extended pipe method in order to improve heat transferring efficiency Piping Service Space It uses Slit Fin whose heat efficiency is maximized the contacting area between copper pipes and fins is a mechanical extending pipe type to improve heat transferring efficiency Fan amp Motor Ass y It is selectable depending on pipe connection direction left and right and as it has wide pipe service space making it easier to do piping works Operational switch is attached on the opposite side against the pipes Drain Pan p It is designed to have sufficient capacities so that the condensed water coming from coil is not dropping on the ceiling and floor Air Filter As this filter can remove even fine impurities indoor it is always able to maintain fresh and cozy indoor life environments and it is also easy to handling with its high capacity removable structure 07 Major features for Fan Coil Unit Low noised design using turbo fan Stim Compact amp Clean Design It strengthen wind flow and reduces noise by adopting 3 dimensional aerodynamic typed turbo fan Compact design for installation in low ceiling is not an issue In various places can be installed without the constraints of space Slim stylish design grille panel created by the curve consistent and it is also designed to be very slim typ
40. i E gt A RI VY AIR GUIDE VANE F da O HANGING BRACKET 7 DESCRIPTION DIMENSION MAT LQTY REMARK 7 RECEIVER REMOTE CONTROL ACRYLIC 4 ee ere 8 DRAIN JOINT PORT gi16 External diameter 1 9 COLD HOT WATER OUTLET PF 3 4 20A 1 a 10 COLD HOT WATER INLET PF 3 4 20A 1 11 DRAIN PUMP 1 1 gj 220V 60HZ 12 SWING MOTOR DC12V 150 g 2 STEPPING MOTOR Specification fF Seion Unt SFC2AK SFC2 4K SFO2 5k Capacity condition Cooling capacity Kcal h 4 an 3 150 5 700 4 200 6 435 T Capacity Heating capacity 8 a 5 ae E a 6 E 11 a 7 300 Volume flow a min 18 Head loss j DI o 7 1 6 Type Single suction turbo Size mm 325 Fan Air flow rate m min 11 13 16 Driving el Motor connected driving Number EA 1 Type Semi hermetic six pole b type insulation Motor power consumption W 80 36 95 48 110 92 Number EA 1 Heat Type Unite type Multi Pass Cross Finned Tube Slit Fin exchanger Fin Pitch 2 1 Inlet A PF 3 4 20A Piping Outlet A PF 3 4 20A Drain mm 16 external diameter Drain Pump embedded 10W head 600mm Exterior Body Galvanized steel 0 8t 1 0t grille panel plastic HIPS ABS material Lagging sound absorbing materials P U Foam Styrofoam P E Foam flame resistant Air flow rate control Turbo and high medium weak operated by wireless remote control wire remote control option Electricity Single phase 220V 60
41. low rate is freely selectable and indoor temperature is constantly maintained making it possible to economically cool and heating space by using 4 contacts touch typed Micom switch Single phase 220V 60hz wireless remote controller is used It is suitable for public facilities including gymnasium church Catholic Church and dining rooms where cooling and heating are difficult to be performed due to individual FCU It uses low noised SIROCCO FAN It is possible to perform ON OFF trom remote area with added remote controlling function Optional specification VERTICAL TYPE FRONT DISCHARGE gt DESCRIPTION DIMENSION MATL QTY REMARK 1 AIR OUT GRILL COATING 2 CONTROL SWITCH 4 contacts touch type 1 1 220V 60HZ 3 CASING 1 2 COATING 4 AIR INLET t1 2 COATING 5 FAN amp MOTOR 1 SIROCCO FAN 6 BASE 23 COATING 7 HEAT amp COOLING COIL OD 3 8 yt0 35 CUAL 1 HOT AND COLD COIL 8 DRAIN PANEL t1 2 CR 1 COATING 9 SCREW BOLT sus 2 10 NAME PLATE 1 11 TERMINAL BLOCK 20A 8P 1 VERTICAL TYPE TOP DUCT DESCRIPTION DIMENSION MATL QTY REMARK 1 SUPPLY AIR CR 1 COATING 2 CONTROL SWITCH 4 contacts touch type 1 14 220V 60HZ 3 CASING t1 2 CR 1 COATING 4 AR INLET t1 2 COATING 5 FAN am
42. lter Vinyl chloride Flush Weight 40 Note 1 capacity condition A cooling capacity indoor air DB 27 WB 21 entrance water temperature 5 heating capacity indoor air 18 entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 e WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 27 LOWBOY EXPOSED TYPE MTEF Perey Fe FRRO RPP R ED fil ii PoP a ey wT PERH HN rare i Gand T fi EEEF raie iiid l E p eeeeeseas mi mi Pe ry if renga i i TEP eo PPR TET HH f HI rT i Ti f iif Fr CNi i Hri TA fi HNI ka ns 7 4 a a i E a A Micom wireless remote control PRODUCT a oe FEATURES 4 E It is well matched to be installed at hotels and restaurants with lower height bright and wide windowed oftices and leisure facilities Air flow rate is freely selectable with 3 stepped rotary switch High Medium Low As its side cover can be opened left and right its pipes are easy to be constructed and pipe directions are easily adjustable depending on the site environments It uses condenser driving single phase inducing motor that has long life and low noise It is easy for pipe connection using flexible tubes Micom wireless remote control switch can be attached Exposed
43. ndenser resin mould motor that has long life and low noise lt is easy for pipe connection using flexible tubes It uses a simple discharging grill capable of adjusting air flow rate by 90 degree so that indoor air can be uniformly distributed Exposed type Micom wireless remote control switch can be attached for additional request 20 FLOOR EXPOSED SLANT DISCHARGE TYPE gt m 4 SFC 20FT 120 x 4 480 120 x 5 600 120 y 6 720 120 8 960 SFC 80FT 120 10 1200 SFC 120FT 1900 DESCRIPTION DIMENSION MATL QTY REMARK WATER OUTLET PF 3 4 20A AIR VENT PT 1 8 MANUAL INNER SIDE CASING H2 GI 2 WATER INLET PF 3 4 20A BS 1 DRAIN PAN ABS 1 PLASTIC AIR FILTER VINYL CHLORIDE 1 FLUSH FAN IMPELLER g145 ABS F SIROCCO A F M 230 FAN HOUSING MOTOR DRAIN HOSE 595 1 220V 60Hz IDg 14 ODg18 SOFT VINYL 1 HEAT amp COOLING COIL 3 87 t0 35 CU AL 1 GRILL 120 120 HEAT RESISTING ABS G High Medium ACCESS DOOR 120 200 ABS 2 COATING EXTERIOR PANEL T K 30 BASE COMPLEX PP SLIT FIN SFC 20FTM 540 SFC 30FTM 660 SFC 40FTM 780 SFC 60FTM 1020 SFC 80FTM 1260 SFC 120FTM DESCRIPTION DIMENSION WATER OUTLET PF 3 4 20A AIR VENT PT 1 8 WATER INLET PF 3 4 20A BS 1 DRAIN PAN ABS 1 AIR FILTER VINYL CHLORIDE 1 FAN IMPELLER g145 FAN HOUSING MOTOR 1 220V 60Hz 10
44. on area so that water leakage is not occurring 2 Lists for supplied components Connection pipe for drain hose attached on the body drain hose 3 The length for drain hose 600mm 4 Make sure to construct individual and common discharging water pipe with downward slope As follows in the direction of the horizontal extension of the drain hose is not possible 5 Make sure to install air ventilation pipe at inlet of the individual discharging pipe Can adversely affect the ability of the drain pump 6 Make sure to construct discharging pipes within the length of drain hose 7 Wrap drain hose and copper pipe with tapes sufficiently after they are connected 8 Make sure to insulate heat after the connection is completed Floor Concealed Type Floor Concealed type _ Floor Concealed installation diagram discharge grille Top cover LA x B Take into full account area of air suction and discharging Front suction type has no interference with floor cloth hanger Take into account that air filter is drawn to the front side p Fill the gap between fan coil unit and discharging grille Front cover Air filter N 42 HYUNDAI CLIMATE CONTROL CO LTD a a g rf E Product installation diagram pe Floor Type OUT LET IN LET OUT LET DRAIN Lowboy Type N HHHH QIN LET OUT LET DRAIN gt Secure the area
45. or controlling m Digital micom attached type for wireless temperature remote controller Detail Photograph Detail Photograph oo Ter FAN COIL UNIT EEEE m An example of micom attached type for controlling temperature Floor Exposed Floor Concealed ae m An example of Digital micom attached type for wireless remote controller Ceiling cassette type Wire and wireless remote controller T Arr Fi L E wit HYUNDAI CLIMATE CONTROL CO LTD m The problems 1 As the cooling and heating are recognized by copper pipe sensor the wrong recognizing problem between heating and cooling has continuously occurred due to wrong attaching position of the sensor This problem is cycling arising from dual systems consisting of heat controller assembling company and pipe installation company In case of N C it is usually closed valve risk for frozen breakage existed In case of N O it is usually opened valve flow rate charge was accumulated by water circulation although it was turned OFF In order to the problems we ve improved location of the switch for cooling and heating and function for preventing frozen breakage and air flow rate control x N C value is designed to opened under 5 and N O valve is designed to reduce the consumption of air flow rate in a way that its valve is closed by supplying the power in ordinary state ible the valve is switched into ON OFF by controlling air flow
46. p MOTOR 1 SIROCCO FAN 6 BASE t23 COATING 7 HEAT amp COOLING COIL OD 3 87 yt0 35 CU AL 1 HOT AND COLD COIL 8 DRAIN PANEL t1 2 R Ae 9 SCREW BOLT sus 2 10 NAME PLATE 1 11 CONTROL BOX 20A 8P 1 e E E se ena SFC 205 1800 390 1050 730 125 SFC 305 1950 800 500 790 490 420 1100 330 334 730 125 EZES 600 390 SFC 50S 1950 1000 200520490 _ _ e 1100 330 334 875 125 800 390 SFC 75S 1950 1200 500 11909 490 460 1140 430 314 915 157 E uz 390 SFC 1005 1050 430 314 963 390 SFC 150S 2100 1600 1100 450 317 1073 To 640 SFc 200S 2100 1700 750 1690 740 410 1140 450 317 1073 1500 640 arate Seen rare ae re a a SFC 20S SFC 30S SFC 50S SFC 75S SFC 100S SFC 150S SFC 200S Capacitycondtion A B A 8 A B A B A BA Cooling capacity Kcal h 6 000 T a 6 600 22 500 35 550 30 000 53 500 T A WE Capacity Heating capacity Kcal h 34 000 33 000 102 000 66 000 136 500 84 000 Volume flow i min 58 75 150 240 200 Head loss mAq 4 1 les U3 4 1 2 3 Type Double suction turbo type Fan Air flow rate m min 23 34 48 70 90 130 180 Driving Motor connected driving Number EA 1 1 1 2 2 2 2 Type Semi hermetic six pole b type insulation Motor Power consumption W 145 420 420 840 900 1100 1500 Number EA 1 1 1 2 1
47. pacity condition A cooling capacity indoor air DB 27 C WB 21 C entrance water temperature 5C heating capacity indoor air 18 C entrance water temperature 80 C 2 capacity condition B cooling capacity indoor air DB 27 C WB 19 5 C entrance water temperature 7 C heating capacity indoor air 21C entrance water temperature 60 C x adopting BLDC motor 13 CASSETTE TYPE PRODUCT FEATURES With its structure capable of in taking outer air it is able to suction the constant amount of outer fresh air depending on the construction method of consumers It is possible to acquire more calm and strong air flow rate using turbo fan As its indoor equipment is slim it is easy to be installed at lower space ceiling As the air flows is not directly contacted with the ceiling by the installed engineering projection it prevents the ceiling from being polluted Registered the patent Built in automatic drain pump with head of 600mm from outlet It is able to connect maximum 16 sets when wired remote control switch is used Discharging air flow is uniform with the added swing function Low power consumption and high efficiency by adopting BLDC motor option 2 WAY CEILING CASSETTE TYPE gt DESCRIPTION DIMENSION MATL QTY REMARK 1 INTERIOR GRILLE ASS Y HIPS 1 COLOR WHITE BEIGE A P er ARENT SLIDING TYPE TR ee ATTACHMENT SNAPS ets NAME PLATE AS zis Nor RETURN GRILLE COLOR WHITE BEIGE A
48. temperature m The valve and fan in the previous product in case of mechanical air flow controlling was turned OFF immediately right after the product was turned OFF But in case of the current product Its valve is turned OFF immediately and its fan is turned OFF after lasting 20 seconds which is needed for discharging internal heat in unit l l l e m Function for power failure compensation a When the Main Power failure occurs the product memorizes various operational conditions including ON OFF automatic high medium low for air flow rates which makes it possible to resume the operation by previous conditions FAN MODE VALVE MODE is freely selectable By DIP switch What is FAN MODE FAN and valve is turned ON or OFF simultaneously by the difference between the assigned desired temperature and the current temperature What is VALVE MODE Only the valve is turned ON or OFF the FAN maintains ON by the difference between the assigned desired temperature and the current temperature gj DIP switch adjustment makes it possible to use the product continuously regardless of the valve type N C or N O is changed during its use j Self diagnostics function If the abnormality for temperature sensor occurs the circuit board is not running Operation LED lamp is not running 39 1 2 4 Way Connection 1 2 4 Way ceiling cassette connection ADDSW SFC4CM01 MICOM SEL
49. type for additional request 28 LOWBOY EXPOSED TYPE wooer a o e edni 4 SFC 20L 940 120x 4 480 1 1 SFC 30L 1060 5 1 1 SFC 40L 1180 6 1 2 SFC 60L 1420 120 x8 960 8 1 2 SFC 80L 1660 10 2 3 SFC 120L 1900 12 2 4 DESCRIPTION DIMENSION MAT L QTY REMARK 1 WATER OUTLET PF 3 4 20A BS 1 2 AIR VENT PT 1 8 BS 1 MANUAL INNER SIDE CASING 1 27 Gl 2 WATER INLET PF 3 4 20A BS 1 ABS 1 PLASTIC AIR FILTER VINYL CHLORIDE 1 WASH 145 ABS F SIROCCO lt 1 220V 60Hz ASS Y M DRAIN HOSE ID214 0D218 SOFT VINYL 1 0D3 8 x 0 35 CU AL 1 SILT FIN 120 x 120 HEAT RESISTING ABS G High Medium CONTROL S W a 1 ROTARY 120 x 200 ABS 2 COATING 14 EXTERIOR PANEL t1 0 CR 1 LOWBOY CONCEALED TYPE gt MODEL SFC 20LM SFC 30LM F M 3 4 5 6 7 8 9 10 11 12 13 SFC 120LM DESCRIPTION DIMENSION MATL QTY REMARK 1 WATER OUTLET PF 3 4 20A BS 1 2 AIR VENT PT 1 8 BS 1 MANUAL 3 WATER INLET PF 3 4 20A BS 1 4 DRAIN PAN ABS 1 PLASTIC 5 AIR FILTER VINYLCHLORIDE 1 WASH 6 FAN IMPELLER 145 ABS F SIROCCO 7 MOTOR 1 220V 60Hz ASS Y M 8 DRAIN HOSE ID914 0D218 SOFT VINYL 1 9 HEAT amp COOLING COIL 0D3 8 x t
50. ure 5 heating capacity indoor air 18 entrance water temperature 80 2 capacity condition B cooling capacity indoor air DB 27 WB 19 5 entrance water temperature 7 heating capacity indoor air 21 entrance water temperature 60 Dimension in is for concealed type 29 PRODUCT FEATURES Indoor space utilization is better by installing it on the ceiling Air flow adjusting switch is additionally provided apart from unit It uses condenser resin mould motor that has long life and low noise It is easy for pipe connection using flexible tubes Micom wireless remote control switch can be attached Exposed type for additional request 30 CEILING EXPOSED TYPE a SFC 20C 940 215 169 120 x10 1200 120 x 10 1200 1200 DESCRIPTION DIVISAS MATL QTY REMARK eee 1 WATER OUTLET PF 3 4 20A i 2 AIR VENT PT 1 8 BS i ae 4 WATER INLET maa 20A H Manual 5 DRAINPAN 6 ee __ FILTER t ae 1 chloride a SSE 7 FAN IMPELLER e f 8 FANHOUSING 9 ae ae 220V 60Hz 10 DRAIN CONNECTION NIPPLE 123 15A SFC 120C 12 GRILLE 120 v 1 20 High Medium g 13 CONTROL S W
51. y by adopting BLDC motor CEILING CASSETTE SLIM TYPE gt 15 Ceiling punching tolerance 1070 15 She 1000 ai 2 DESCRIPTION BD Yt Ko 0 Ta O REMARK 1 SUCTION GRILL HIPS 1 WHITE BEIGE 3 DRAIN PAN BS 4 FLAP HIPS 1 5 SWING MOTOR DC12V 15 4 1 STEPPING MOTOR g punching tolerance Cellin 19 1100 ery DESCRIPTION DIMENSION MATL QTY REMARK 6 FLOWER D90 SAN G20 1 D90 Q 7 DRAIN PUMP HEAD 600m 1 220V 10W 9 CONTROL BOX Gil 1 TTA Specification gt T 54 Cooling capacity keal h 4 800 capadty Heating capacity e o0 Volume flow min Oss 11 7 13 5 15 3 Head loss mAq 1 42 1 74 2 34 4 1 Fan Type Centrifuge Type Air flow rate n min 9 11 15 15 Type BLDC Motor Power consumption W 9 11 15 15 Number EA 1 Heat Type Cross Finned exchanger Fin Pitch mm Za Ei mm 20A PF 3 4 Piping Outlet mm 20A 20A 20A 20A Drain mm 16A PT 1 2 16A PT 1 2 16A PT 1 2 16A PT 1 2 Electricity Single phase 220V 60Hz Data link Shield cable AWG24 x 4C Air Filter Bacteria proof filter 7 DxWxH 410 x 900 x 135 Panel mm 460 x 1 100 x 30 Weight kg 9 11 15 15 Note Temperature condition Air side cooling DB 27 heating DB 21 Water side cool water inlet 7 outlet 12 hot water inlet 60 11 4 WAY CEILING

Download Pdf Manuals

image

Related Search

03_hyundai_fan_coil_unit_(48pages)

Related Contents

電波時計 取扱説明書  Mantel Assembly Instructions  Lowe`s  User Manual Armadillo 9X Series Models  Kit Plug&Play – Suzuki GSX–R K5  Reference Manual    Frigidaire FGHS2368L User's Manual  Bell DBA-8Z User's Manual  CamFlex® - kummert.de  

Copyright © All rights reserved.
Failed to retrieve file