1. User manual 4vaxis NOILV 13 www elationlighting com 2015 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Netherlands 31 45 546 85 66 31 45 546 85 96 fax www e
2. and so on Note During start up the SIXPAR 300IP will automatically detect whether a DMX data signal is being received or not If the fixture is not receiving a DMX signal please check the following he or Spin XLR input plug cable with DMX signal from controller is not connected or is not inserted completely into the DMX input jack of the fixture he DMX controller is switched off or defective The DMX cable or connector is defective A DMX terminator has been inserted into the last fixture in your DMX chain 15 SIXPAR 300IP User Manual ver 1 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The SIXPAR 300IP comes with an easy to navigate system menu The next sections will cover how to access each menu function LCD CONTROL PANEL DISPLAY The 4 button control panel see image below located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SIXPAR 300IP During normal operation pressing the MODE button will navigate through the different function menus Once you reach a desired menu press the ENTER button to select that menu The variable field that can be adjusted within the selected menu will begin to flash Using the UP or DOWN buttons adjust the field until the desired value is displayed For example the CHANNEL CH menu variable field can be set to 06 07 08 or 12 Pressing the ENTER button once will confirm your selected valu
3. www elationlighting com WARRANTY REGISTRATION Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting Customer support at 323 582 3322 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 6 SIXPAR 300IP User Manual ver 1 ETATION www elationlighting com LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years 730
4. IT MAY BE HOT NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury e Never look directly into the light source of this fixture prevent risk of injury fo your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times e Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 8 SIXPAR 300IP User Manual ver 1 www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE Ensure ALL connections and end caps are properly sealed with a dielectric grease available at most electrical suppliers to prevent water corrosion and or electrical short circuit During
5. days and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months 180 days from the original date of purchase This warranty excludes discharge lamps and all product accessories This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is owner s responsibility to establish the date and place of purchase by acceptable evidence at the fime service is sought B For warranty service send the product only to the Elation Professional amp factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If any product is sent it must be shipped in its original package and packaging material No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional amp shall have no liability what so ever for loss and or or damage to any such accessories nor for the safe return thereof C This warranty is void if the product serial number and or labels are altered or removed if the product is modified in any manner which Elation Professional amp concludes after inspection affects the reliability of the product if the product has been
6. the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating to prevent any fire hazard Minimum distance of inflammable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years fo come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than MIO x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to transport the fixture in for service DO NOT TOUCH the housing bare hand during its operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing Or serving 9 SIXPAR 300IP User Manual ver 1 www elat
7. 11 112 115 116 119 120 123 124 127 128 131 132 135 136 139 140 143 144 147 148 151 20 SIXPAR 300IP User Manual ver 1 COLOR MACROS OFF RED GREEN BLUE WHITE AMBER UV RED GREEN RED BLUE RED WHITE RED AMBER RED UV GREEN BLUE GREEN WHITE GREEN AMBER GREEN UV BLUE WHITE BLUE AMBER BLUE UV WHITE AMBER WHITE UV AMBER UV RED GREEN BLUE RED GREEN WHITE RED GREEN AMBER RED GREEN UV RED BLUE WHITE RED BLUE AMBER RED BLUE UV RED WHITE AMBER RED WHITE UV RED AMBER UV GREEN BLUE WHITE GREEN BLUE AMBER GREEN BLUE UV GREEN WHITE AMBER GREEN WHITE UV GREEN AMBER UV Mm www elationlighting com PROFESSIONAL ELATIONO SIXPAR DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 152 155 156 159 160 163 164 167 168 171 172 175 176 179 180 183 184 187 188 19 192 195 196 199 200 203 204 207 208 211 212 215 216 219 220 223 224 227 228 231 232 235 236 239 240 243 244 247 248 251 252 255 COLOR MACROS continued BLUE WHITE AMBER BLUE WHITE UV BLUE AMBER UV WHITE AMBER UV RED GREEN BLUE WHITE RED GREEN BLUE AMBER RED GREEN BLUE UV RED GREEN WHITE AMBER RED GREEN WHITE UV RED GR
8. Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Male Edison to IP Female Power Cable 6 6 ft 2m e Male 3pin XLR to IP Female DMX Input Cable 3 3 ft 1m Female 3pin XLR to IP Male DMX Output Cable 3 3 ft 1m e Manual amp Warranty Card CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting corn for any comments or suggestions For service related issue please contact Elation Professional amp ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu 5 SIXPAR 300IP User Manual ver 1
9. EEN AMBER UV RED BLUE WHITE AMBER RED BLUE WHITE UV RED BLUE AMBER UV RED WHITE AMBER UV GREEN BLUE WHITE AMBER GREEN BLUE WHITE UV GREEN BLUE AMBER UV GREEN WHITE AMBER UV BLUE WHITE AMBER UV RED GREEN BLUE WHITE AMBER RED GREEN BLUE WHITE UV RED GREEN BLUE AMBER UV RED GREEN WHITE AMBER UV RED BLUE WHITE AMBER UV GREEN BLUE WHITE AMBER UV RED GREEN BLUE WHITE AMBER UV COLOR CHASE MACROS 00 20 NO Function 21 40 30 Color Chase 41 60 6 Color Chase 61 80 Color Fade Chase 81 255 NO Function COLOR CHASE MACROS SPEED Chase Speed of CHANNEL 10 SLOW to FAST DIMMING MODES STANDARD LLL 00 255 0 20 21 40 41 60 61 80 81 100 101 255 os THEATER NO Function 2l SIXPAR 300IP User Manual ver 1 www elationlighting com CLEANING AND MAINTENANCE C A U T O N Disconnect power before cleaning or maintenance CLEANING Frequent cleaning is recommended insure proper function optimized light output and an extended life The frequency of cleaning depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture s optics e Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt debris accumulation Never use alcohol solvents or a
10. MBER LEDs UV LEDs FULL ON DIMENSIONAL DRAWINGS 14 4in m Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 24 SIXPAR 300IP User Manual ver 1 ORDER CODE TRIGGER CLAMP SIXPAR300 GFH SIXPAR BD300 EWDOO SIXPAR 2MDLC SIXPAR 2MPLC SIXPAR 3MDLC SIXPAR 3MPLC SIXPAR SMDLC SIXPAR SMPLC SIXPAR 1 OMDLC SIXPAR 1 OMPLC SIXPAR 20MDLC SIXPAR 20MPLC SIXPAR DIAC SIXPAR DOAC SIXPAR PIAC SIXPAR POAC SIXPAR TERMINATOR www elationlighting com OPTIONAL ACCESSORIES 9 8 ft 3m IP Power Link Cable SPECIAL ORDER ITEM 16 4 ft Sm IP Data Link Cable SPECIAL ORDER ITEM 16 4 ft Sm IP Power Link Cable SPECIAL ORDER ITEM 32 8 ft 10m IP Data Link Cable SPECIAL ORDER ITEM 32 8 ft 10m IP Power Link Cable SPECIAL ORDER ITEM 65 6 ft 20m IP Data Link Cable SPECIAL ORDER ITEM 65 6 ft 20m IP Power Link Cable 25 SIXPAR 300IP User Manual ver 1
11. dColrAdjsiment PON Adjust STROBE SPEED 00 SLOW 0 162 99 FAST 20Hz 6 Color Chase Macro 17 SIXPAR 300IP User Manual ver 1 www elationlighting com DIMMING CURVES The DimCurve menu allows you select one of the following preset dimming curves Standard Stage TV Architec or Theatre See diagram below for more details Dimmer 100 50 Ramp Effect 5 0S Fade Time TE 1S Fade Time NN RN NR RN 18 SIXPAR 300IP User Manual ver 1 ETATION www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES ELATION SIXPAR 300IP DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 0 255 Red 0 100 2 2 2 0 255 Green 0 100 3 3 3 0 255 Blue 0 100926 WHITE 0 255 White 0 100 EN 255 E 0 100926 PTT E 0 255 U V 0 100 MASTER DIMMER 255 Dimmer 0 100 DO 19 SIXPAR 300IP User Manual ver 1 ECATIOWw www elationlighting com PROFESSIONAL SIXPAR DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 8 11 12 15 16 19 20 23 24 27 28 31 32 35 36 39 40 43 44 47 48 51 52 55 56 59 60 63 64 67 68 71 12 15 16 79 80 83 84 87 88 91 92 95 96 99 100 103 104 107 108 1
12. e Exit at any time without making any adjustments by pressing the MODE button INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON the display shows the following information Update SIXPAR s x Fixture Software Version Greater than or equal to 16 SIXPAR 300IP User Manual ver 1 ETATION www elationlighting com LCD CONTROL PANEL LOCKOUT When the Display ON menu is set to OFFI the LCD display will turn OFF after 30 seconds and the 4 button Control Panel will be LOCKED To unlock the 4 button LCD control panel follow these steps When locked the display will show LOCKED Press UP then the display will change to LOCKED one disappears Press DOWN then the display will change to LOCKED two disappear Press UP then the display will change to LOCKED three disappear Press DOWN then the display will change to LOCKED 4 disappear Press ENTER then the display will change to LOCKED and then become unlocked pv do do CO XO Ll SIXPAR SYSIEM MENU specifications are subject to change without any prior written notice MENU OPTIONS VALUES DESCRIPTION CH 06 07 08 12 DMX Channel Mode ADDR 001 512 DMX Address Setting SALVE MODE Set Fixture A Slave Unit N LCD Display Always ON Display ON OFF LCD Display OFF after 30 seconds OFFI LCD Display OFF After 30 Seconds and LOCKED 1 MANUAL Manu
13. ionlighting com FIXTURE OVERVIEW 1 Button 2 UP Button 3 DOWN Button 4 ENTER Button 9 Power IN 6 DMX IN 7 DMX Out 8 Power OUT 10 SIXPAR 300IP User Manual ver 1 www elationlighting com FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5 0 ff 1 5m away from any flammable materials decorations pyrotechnics etc ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and or installations 35 CAUTIONS For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Min Max ambient operating temperature for this fixture is 5 F to 113 F 15 C 45 Do not use fixture under or above this temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 210 Ibs 95 kg Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing Ensure ALL connections and end caps are properly sealed with a dielectric grease available at most electrical suppliers to prevent water corrosion and or electrical short circuit L POWER LINKING Max number of units that can be power linked is 5 units 110V and 10 unit
14. lationlighting eu info elationlighting eu DOCUMENT VERSION 3 Please check www elationlighting com for the latest revision update of this manual D t Soft oo ocumen soriware Channel Modes Version Version 2 SIXPAR 300IP User Manual ver 1 www elationlighting com CONTENTS kz Beedeies 19 m Fixture Installation kum mus 3 SIXPAR 300IP User Manual ver 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable ArtNet to DMX converter on the market today The SIXPAR 300IP has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance IP65 RATED An IP rated lighting fixture is one which is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress entry of external foreign objects such as dust and water The International Protection IP rating system is commonly expressed as IP Ingress Protection followed by two numbers i e IP65 where the numbers define the degree of protection The first digit Foreign Bodies Protection indicates the extent of protection against particles enteri
15. merchantability or fitness are limited in duration to the warranty periods set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said periods have expired The consumer s and or dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professionale be liable for any loss and or damage direct and or consequential arising out of the use of and or the inability to use this product G This warranty is the only written warranty applicable to Elation Professionale products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 7 SIXPAR 300IP User Manual ver 1 ETATION www elationlighting com SAFETY INSTRUCTIONS The SIXPAR 300IP is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device be grounded properly Only qualified personnel should perform all electrical connections C A U T O N UNPLUG POWER BEFORE SERVICING FIXTURE NEVER TOUCH FIXTURE DURING OPERATION AS
16. mmonia based Cleaners MAINTENANCE Regular inspections are recommended to insure proper function and extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every 3 months to make sure the circuit contacts are in good condition and prevent overheating e sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury e Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture fall and seriously injure a person s Inspect all moving parts and make sure there are no signs of wear and rotate move without imbalances Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 22 SIXPAR 300IP User Manual ver 1 EtATION TECHNICAL SPECIFICATIONS FEATURES IP65 Rated 15 Beam 25 Field Angles 5 Variable Dimming Curve Modes Dual Yoke Flo
17. ng the fixture and the second digit Water Protection indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and high pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environment installations Installing this fixture in a marine and or coastal environment may cause corrosion and or excessive wear fo the interior and or exterior components of the fixture Damages and or performance issues resulting from installation in a marine and or coastal environment will void the manufactures warranty and will NOT be subject to any warranty claims and or repairs Ensure ALL connections and end caps are properly sealed with a non conductive dielectric grease available at most electrical suppliers to prevent water ingress condensation and or corrosion OPTIONAL CORROSION RESISTANT COATING Optional Corrosion Resistant Coatings may be available for this fixture Please consult your Elation Professional sales representative for details 4 SIXPAR 300IP User Manual ver 1 www elationlighting com UNPACKING Thank you for purchasing the SIXPAR 300IP by Elation Professional Every SIXPAR 300IP has been thoroughly tested and has been shipped in perfect operating condition
18. nufactures to be linked together and operate from a single controller This is possible as long as all the fixtures and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is sent out as serial data that travels frorn fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use the SIXPAR series IP rated DMX cables listed in the OPTIONAL ACCESSORIES section at the end of this manual When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to address to that fixture no matter where if is located in the DMX chain The SIXPAR 300IP can be controlled via DMX 512 protocol and the DMX address is set via the control menu DATA CABLE DMX Cable REQUIREMENTS For DMX and Master Slave Operation Your fixture and your DMX controller require a standard 3pin or Spin XLR connector for data input and data output see figure bel
19. or Stand Multiple Unit Power Linking RDM Remote Device Management Rugged Die Cast Aluminum Exterior Flicker Free Operation for TV and FILM SOURCE 18 12W 6 in 1 RGBAW UV LEDs 100 000 Hour Average LED Life EFFECTS Electronic Strobe Color and Chase Macros Electronic Dimming 0 100 5 Variable Dimming Curve Modes CONTROL CONNECTIONS 4 DMX Channel Modes 6 7 8 12 4 Button Touch Control Panel LCD Menu Display IP DMX and Power In Out SIZE WEIGHT Length 14 4 365mm Width 6 2 157mm Vertical Height 14 4 365mm Weight 21 6 lbs 9 5 kg ELECTRICAL THERMAL AC 110 250V 50 60Hz 220W Max Power Consumption Power Linking 5pcs 110V 10pcs 240V 5 F to 113 F 15 C 45 C APPROVALS RATINGS CE IP65 CM C US LISTED Intertek www elationlighting com Optional Corrosion Resistant Coating may be available for this fixture Please consult an Elation sales representative for details Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 23 SIXPAR 300IP User Manual ver 1 Erariow www elationlighting com PHOTOMETRIC DATA lt N N 15 25 p Beam Field ee d 3m 4 Distance du 15 Beam Diameter 04 13 25 Field Diameter RED LEDs GREEN LEDs 8 400 780 _ BLUE LEDs WHITE LEDs A
20. ow Also remember that a DMX line must be daisy chained and cannot be split 13 SIXPAR 300IP User Manual ver 1 www elationlighting com DMX 512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the SIXPAR 300IP The diagram below illustrates a typical DMX 512 connection when the fixture is in the 12 Channel Mode You can chain multiple panels together through serial linking Always be sure daisy chain your in and out data connections never split or Y your DMX connections 2 2 o gt a ra AS _ Address 25 SS DMX mnt CONTROLLER DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behavior Use the SIXPAR DMX Terminator End Cap listed in the OPTIONAL ACCESSORIES section at the end of this manual T n Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Re
21. repaired or serviced by anyone other than the Elation Professionale factory unless prior written authorization was issued to purchaser by Elation Professional amp if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professiondl will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional amp under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with the products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional in connection with this product including warranties of
22. s 240V CLAMP MOUNTING The SIXPAR 300IP provides a unique integrated Dual Yoke Floor Stand When mounting this fixture to truss be sure to secure an appropriately rated clamp using an M10 screw fitted through the center hole of the Dual Yoke Floor Stand 11 SIXPAR 300IP User Manual ver 1 www elationlighting com SECURING Regardless of the rigging option you choose for your SIXPAR 300IP always be sure to secure your fixture with a safety cable MOUNTING POINTS Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Fixture is fully operational in the specific mounting positions as illustrated below w e eie yr S Z gt D Jw1wawaj ms Always use a Safety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails 12 SIXPAR 300IPTM User Manual ver 1 www elationlighting com UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different ma
23. sistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture PIN2 14 SIXPAR 300IP User Manual ver 1 www elationlighting com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller so the correct fixture resoonds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting address for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the SIXPAR 300IP when in the 12 Channel Mode you should set the starting DMX address of the first unit To 1 the second unit to 13 1 12 the third unit to 25 13 12