Home
Weigh ahead batching
Contents
1. TEST No s nn TFCT TFCT Tu ko Reprint Docket Show Detail Edit Detail Change Cancelled Highlight a docket by clicking the left blank column of the row Once a docket is chosen in this way options to reprint or make changes become available t ecc CT Je OTTO OT oo co n l LT TI OT Oo Oo ON ON T 1 Fa Ti lt ha ha ha ha rof Ba pal ta rol cal ca co ea ea ea ca ca ea ca E cd ms OD P adr 1 co 3 Limited changes only are allowed to a docket It is possible to correct for using the wrong order truck or driver Other batch details remain unchanged for quality assurance purposes st Change Order Truck or Driver on docket Docket Old Values New values Order AZFIRM M Truck 3 486 Driver WINE Ready to batch With a plant that has been set up a database of mix designs orders and trucks we are ready to let the batching computer do the rest of the work Batching a load of concrete requires just an order a quantity and a truck The computer knows the project from the order and the project Knows the customer 24 W New Job Batch No 46 Order AZFIRM Quantity Trim Returned 152 42 20 0 Truck Driver 487 LINC Profile STARTUP Agg Hopper Front Rear Motes Refere
2. The Type allows for different measuring configurations If a weigh hopper is on load cells then the weight increases as material is batched Up to hopper but if for instance a cement silo is on load cells then the weight decreases as cement is batched Down no hopper The value Up Direct is for when there is no hopper and material is direct into the truck bowl typical of admixtures and water measured by flowmeter End loader plants generally have a remote display visible to the loader driver The Ext Display value is the port to which the external display is connected Except for an end loader weigh hopper the value is generally None Multiplier converts a physical measurement to a true measurement For scales the value can be left as zero which is treated as a multiplier of 1 i e there is no difference between the weight displayed on the scale and the actual scale weight If however an admixture flowmeter gives one pulse for every 10 ml then the multiplier needs to be set to 10 to convert pulses to milli litres of admixture If water is measured by a flow meter that gives 50 pulses per litre then the multiplier would be 0 02 Enabled is a yes no value tick box to indicate the counter is available for use If for example at a dual aggregate weigh bin plant one hopper was damaged it can be taken off line simply by unticking the check box then re ticking after repair This is a lot more convenient than deleteing then re entering the wh
3. Phone 041 20000765 Fall o oo em CreditLimit fr CurentCredit 0 Notes ContactName ContactPosition ContactPhone Contact ax Contacte mai EN Update Cancel The customer record is self explanatory The address is an invoicing address which may be different from a customers order delivery address Most plants set up a single cash sale customer for one off cash jobs Contractors Code NMC Mame Neil Mansell Concrete Address Address Address3 Update Cancel The contractor truck owner record is very simple 19 Driver records are also simple to understand Drivers ANTHONY KUNDA PARK Cancel Cancel Contractors Owner and Drivers must already be in their corresponding tables before a truck record can be completed The Capacity is the largest load this truck may take A warning is produced at batch time if you attempt to batch a load that exceeds the truck capacity 20 Projects sW Projects BETTER BRICKLAYING BETTER BRICKLAYING ef Outlook Dr Nindery Caution inside school zone 7 30 until 09 00 MiLode it Description Price a S20MPa 7mmz230mm Blockfil GP Ea Update Cancel A project is created for each customer delivery address Pricing for different mixes to the project location goes here A project may run for a very long time or may just be for one load A single Cash projec
4. Conveyors V Incline Conveyors and Augers EM op AGGREGATE The Run Relay is the relay number for turning the conveyor and off Some motors have an output that comes on when the motor is up to speed This is the input to the Is Running relay If there is no Is Running then set to 1 and the computer assumes the conveyor is running if the run relay is on The Pre Run Time is the number of seconds from the activation of Run before any feeding hopper will open May be necessary if a conveyor takes a while to get up to speed Post Run Time is the number of seconds the conveyor will continue running after a discharging hopper is empty On an aggregate incline conveyor this is the time that material takes to get from the bottom of the belt to the top Vibrators sN Vibrators J amp GG2 VIB JCEM VIB EN Vibrators can be set to operate in one of 3 Modes as appropriate e Mode 1 The vibrator comes on when the counter is less than the set value E g when the scale of an aggregate hopper gets below the value A good mode for hoppers that have difficulty discharging when nearing empty e Mode 2 The vibrator comes on when the rate of flow is lower than the value The value is measured in units per second For cement this would be in Kg second e Mode The vibrator cycles on and off On for Value seconds then off for Value2 seconds Relay is the relay number for activating the vibrator Relays There
5. is a table for documenting relay usage a Relays Relay PLC Direction Description U 4 Relays 0 to 127 are used as outputs i e for turning something on sl Relays INN x Relays 128 to 255 are used as inputs e g a limit switch is closed 10 Discharge Profiles sW Discharge Profiles 2000 100 0 100 4 0 __ 88 EE 1 E _ 3 EH ED EE EN _ ED __ END _ EH ED _ SE ED __ MED Create new profile based on this profile Discharge profiles control how a batched mix is loaded into the truck The profile controls both the speed and sequence of loading Different sized trucks may have different discharge profiles special mixes may require a special profile In the above example the computer will control the aggregate discharge hopper so that 6000kg minute is discharged onto the incline conveyor the cement will be discharged at 2000kg minute maximum The loading sequence may be up to 15 distinct intervals the last indicated by a row of all zeros The computer does not move on to the next sequence until everything in the current sequence has completed Each cell in the loading sequence table represents a of the total activity Every column in the sequence table will add up to 10096 or zero if unused In the above example firstly 8596 of the total water and all the admixtures will be discharged together into the truck 11 When that has fully completed 10 of
6. oon OX Software Equinox BATCHtech User Manual metric version Version 15 01 1 Aug 2015 Equinox BATCHtech automated batching Units Aggregates and cements are measured in kilograms Water is measured in litres or Kg Admixtures are measured in milli litres or milli litres 100kg Cementitious Unless explicitly stated otherwise times are measured in milli seconds e g jog a jog time of 200 would pulse the corresponding air solenoid for 1 5 of a second Plant Configuration The Equinox batching software is the same for all batch plants whether it be a simple single aggregate hopper end loader configuration with one cement or a very large overhead bin design with several cementitious products One single program is very beneficial for operators owning several plants and for the rapid distribution of software improvements and updates In order for this to happen the actual plant is configured by parameters at initial setup After initial plant setup most parameters never need changing The standard Equinox Batching system supports up to 16 counters divided into 8 weigh type devices and 8 volumetric pulse devices sW Counters E c NT E 20 r to TE Ji zl ite SCALE 5 Up ta Hopp rte y H The Class for each counter is selected from a drop down when the field is clicked The Class is one of AGG CEM WTR ADMX ADDV standing for Aggregate Cement Water Admix and Additi
7. the aggregate will be discharged When that has happened the cement and remaing aggregate are discharged together Finally the remaing 1596 of water is added on its own The easiest way of creating a new profile is to first select a profile close to that required and click the Create new profile based on this profile button Then modify as required and save The Post Delay column allows for entering a value in seconds When a sequence completes if there is a non zero post delay on that row the next sequence will not be started until after post delay seconds One could for instance create a profile that pauses for 60 seconds halfway through the loading to allow for the manual loading of colored oxide or fibres into the bowl 12 Mix Designs Mix designs are the recipes for concrete products The mix designs must be based on the dry weights of constituent materials Wet materials are compensated for at batch time by an assigned moisture 96 x UTENTE I o MH 3z2MPa 2 mrm Bmm slump GP 20 SAND I jog _ 2 _ 3 _ ED ED Ll 8 DEI _ 8 _ 3 _ 1 __ _ ED _ 13 BB __ 19 Create new bis based on this kis Each row of the mix design has the material and quantity required for one cubic metre of product If a product is not enabled it will not be batched The batching sequence of materials using the same counter is the order in which they occur in the mix design Materials using different counter
8. Direct measuring moisture probes may also be connected to the batching system If recycled water is being used the 96 weight due to suspended solids may also be set The batch computer will increase the water content to compensate for the weight attributable to the suspended solids 15 The plant screen is used for setting miscellaneous relays and other details After initial setup there is nothing in the plant screen that requires changing or fine tuning Serial Humber site Prefix Phone 65560 mm Fas EN Site Details Docket Printer OKI MICROLINE 320 TU gt Email address es to send transaction data Iw Print Docket Determining Configuration t At Start of Batch ingl Block Plant Tandem agg bin f At Start of Loading aximum single 75 batch size Moisture Probe Wet Mix Plant At End of Loading At End of Slumping Docket Style Stationary Miser Lael e Daye history kept k in Positi 153 P to 152 H Id Batchi ruck in Position uta Manua old Batching ABN Dut of Tolerance 42 ama idest IE Pulse Reset 29 Accept Tolerance 154 5000 Batch Ready Ml BST lt 0 Save Settings The Maximum single batch size is generally governed by the physical sizes of the weigh hoppers and may well be less than the capacity of the largest truck bowl If a requested batch is larger than this value then the load will be batched in two or more drops E g a req
9. RM 487 LINC 4 2 MRTS 0 SSOMPa 20mm 160mmSlump DRY Tremie T arwin Place Mountian Ceek RE 100 Delete Pending Batch allows for a single batch number to be selected Delete all pending batches removes everything from the queue Neither affects the current batch once it has commenced Abort current batch clears the process control computer and PLC Everything will stop and relays will all switch off The batch can not be restarted For a temporary halt switch the plant to Manual then back to Auto when ready If the batcher should switch the plant to manual and complete a batch manually for any reason then it is essential to click the Abort current batch menu option before another batch is queued Cancel Truck in Position allows the truck ready signal to be removed It only has effect before the truck has started loading The batching of materials into weigh hoppers will complete but the load will not go into the truck until the Truck Ready button is pressed again 28
10. aterials Tolerances Tol 96 and Tol Max are used during batching The tolerance used in batching is the minimum value of the two and depends on the batch size E g if Tol is 5 and TolMax is 50 for a material in a mix that uses 400kg cubic metre of that material then when batching a 3 metre load the tolerance will be the lesser of 50 and 5 of 1200 60 ie a tolerance of 50 kg In a 1 metre load the tolerance is the lesser of 50 and 5 of 400 giving a tolerance of 20kg Cost 1000 is used to calculate the actual raw material cost of a mix design May be left as zero if this ability not required or entered as the cost per tonne for aggregates and cements or the cost litre of admixtures Modifiable means that the quantity of this material in a mix design may be altered at batch time This usually only applies to admixtures such as retarders or accelerators Only materials that are Enabled may be batched If a material is temporarily unavailable then unticking Enabled will prevent the batching of a mix containing this material from starting Bins Raw materials are stored in a bin for batching The bin parameters describe the operation of that bin Material Bins Relay 28 Relay2 1 _ CAMCEL Jog Tine 1250 UPDATE Vibrator NN Enabled Choose any descriptive Name and select the Material that the bin holds from the dropdown In an overhead bin plant it is common for two or more
11. bins to contain the same material because a lot of that material is used in the mixes If you Link a bin with another then during batching the material will be drawn from both bins simultaneously If bin A is linked to bin B then you must also link B to A Although uncommon in practice 3 bins A B and C could be linked by A links to B B links to C C links to A Bins can only be linked if they contain the same material The Class of a bin must match the class of the material The Counter is the scale or pulse meter that is used for measurement when this bin is used Relay is the electrical relay number that operates the bin and would never be changed after initial set up If a bin has a fast and slow feed ability then Relay2 is the slowfeed relay Whenever a relay is not present then it must be given the value of 1 At an end loader plant an Aggregate bin would typically have both relays set to 1 as there is no automatic operation to start the feeding of material to be weighed Precut is to make allowance for inflight material and is the amount to be subtracted from the required target weight to determine when the relay switches off so that the final weight will be the target weight The value to be given is determined by observing the scale during manual operation Use Dynamic indicates that the precut value will change automatically between batches based on what happened in previous uses E g if a material went over by 30 kg then the precut
12. lass as its counter Gates specify how many discharge gates the hopper has Most aggregate hoppers have a front and rear gate Water weigh tanks have just one outlet If a hopper has inching gates the gate can move to and stay in any position between closed and open then there will be a relay for open and a relay for close Non inching gates just use the open relay and the gate fully opens when the relay is on and closes fully when the relay is off Any not used relay must be given a value of 1 Close is always 1 for non inching gates Pulse length applies to inching gates only set zero for non inching and is the incremental time that that either open or close is applied in order to increase or decrease the gate aperture If an inching gate takes one second to fully open or close then a pulse length of 200 would allow for 5 different apertures This enables the computer to control the exit rate from the hopper so that conveyor belts do not overflow etc IsOpen and IsClosed are the relay numbers for limit switches that indicate the fully open or fully closed position of a gate Most plants are designed so that the second gate does not start opening until the first gate is fully open Also most plants have interlocks that prevent a hopper being loaded unless the Isclosed relay is ON If the hopper has a Vibrator then choose from the dropdown if the hopper requires a Conveyor motor to be started before discharge then select from the dropdown
13. mlz TOOkg Cem Queue For Batching Change the value and click Update Mix Once batch details are as required click the Queue for Batching button The batch will be entered into the batch queue Batch Oty Mis Order Truck Dive Description gt 45 42 152 LINC AZFIRM 487 4 2 MATS70 SSOMPa 20mm 160mmSlump DRY Tremie Tarwin Place Mountian RE 100 If the plant is in automatic and ready the batch will be removed from the queue immediately and the load will be batched The batcher must press the Truck Ready button on the control panel before the batched load will move from the weigh hoppers to the truck 27 Batch Control _ Equinox Batching V14 05 File Adjustments Database Patines Reports Print AGGI SCALE Delete Pending Batch Delete All Pending Batches Abort Current Batch Cancel Truck in Position Admix manual Batch Batch Available Target Target Actual Actual The batch control menu option affects the current or queued batches Hopper Open LTTE CembVibrator Water Charge Water Disch AggiFClse Agg1 R Close Aggi Vibrator Pending Batch Admix2 Admix3 Admixd re Batch Ready of Tolerance Cem Clos EL 3H Agg2 F Closed Agg2 F Opened Agg2 R Clc Cancel E Stop Auto Truck Rez 46 Batch Qty Mix Order Truck Drive Description 45 42 152 AZFI
14. nce RE 100 J gt 5 WATER WB 1 1 21 Select the order from the drop down Enter the quantity to be batched and select a truck The Trim varies the water from the mix design values and is expressed as litres cubic metre In the above a total of 4 2 x 20 84 litres will be held back Returned allows for a non empty truck to use a returned load All documentation is for the load quantity but the amount actually batched will be Quantity Returned The Driver and Profile that was originally assigned to the truck in the database may be altered and the alteration is for this load only 25 W New Job Batch No 46 x Order AZFIRM Quantity Irim Returned 152 4 2 20 0 Truck Driver func Profile STARTUP Agg Hopper Front 5 Rear Notes Reference RE 100 2115 HRWRRE Materials that are modifiable are highlighted in the batching materials list Note that materials with units of mls 100kg cementitious use that figure in the metre column but the total load column is the actual quantity that will be batched in this case total cementitious FA and GP is 630 1344 1974 o0 total of RE at 220mls 100kg cementitious will be 220 x 1974 100 4343 To change a modifiable material prior to batching click that materials metre value 26 Hotes Reference RE 100 Ma Mete DUST SAN 437 RE Adjust M3 344
15. nter PEME Mixer Auto Manual 8D SEN Mixer Busy 1 Mixer All Done Mixer Precut D BSTX Mixer Charge Select I Done Timer Miser Discharge Mo Discharge Heady 1 Save Settings Some plants run a stationary mixer onsite typically for loading mini trucks The settings for controlling the stationary mixer are also set up from this screen 17 Database SN Equinox Batching 14 05 File Adjustments Batch Control AGG1 SCALE Reports Print Customers Contractors Trucks Drivers Projects Orders AI Orders Incomplete Quick Order Mark previous days orders as complete Mark all orders as complete Cartage Rates Target Recent Dockets Actual Actual Database menu option is for creating tables that are not to do with the plant setup The tables are about the administration and generation of loads The tables are e Customers Person or company buying concrete e Contractors Anyone who owns one or more trucks operating e Trucks All of the trucks e Drivers Details about truck drivers e Projects Delivery location and mix pricing at location e Order Detail about a single mix for project delivery e Recent Dockets Individual docket loads resulting from an order 18 sN Customers Code BETTER BRICELAY ING Type Credit Account gt Account Better Bricklaying Mame J ustin Gotard Address 60 OUTLOOK DR Addrezz2 Address3
16. ole line Raw Materials Raw Materials Cost 1000 Modifiable Enabled 4 MP10 AGG Kg 1 5 50 0 Moy Pocket 10mm Moy Pocket 20mm 20 AGG 1 5 Moy pocket 7mm MP7 AGG Ningi Fine Sand SAND AGG EXP WHITE AGG L1LIL Calide Flyash Sunstate T arong Flyash CEM Sunstate GP CEM WATER WTR Sika AEA ADMX L Sika Visocrete PC HRF2 amp DMX mi 100KgCem Sika Rapid AF ADMX ml 100Kg Cem Sika Retarder M ADM ml 1 NAK Cera IIS I ISI S S ISTIS S ST IS S 1 1 ed Jen cn OT co Go od OT en en IR EOOOOOO Code is used to identify material in mix wheras the Name appears on most printed reports The Short Name is shown on the outdoor weight display used by the loader driver at loader style plants The Short Name must be chosen to satisfy the constraints of the outdoor display it must consist only of characters the outdoor display is capable of showing and have no more characters than the display accommodates Some displays can only show numeric and upper case and are limited to as few as 5 characters Class is chosen from a drop down and is one of AGG WTR ADMX ADDV Units are chosen from a drop down and are Kg for Aggregate and Cement classes Litre or Kg for Water and ml or ml 100kg Cem for admixtures The specific gravity SG is used to calculate the volume of weighed m
17. s can batch simultaneously e g cement and water weigh up at the same time In the above example MP10 MP20 DUST and SAND which are all aggregates will batch up in that order into the aggregate weigh hopper of any plant that has one weigh hopper for all aggregates 13 If correct specific gravity s have been entered against materials in the material setup then the calculate button will show the yield that would be achieved if these exact quantities were batched After entering a new mix design it is a good check to verify the yield as a number not close to 1 is an indication of a material omitted or a wrong quantity NN HN 3z2MPa 2mm Smm slump GP 0 Calculate Enabled fy Calculations terial i 3 2 1 CD Fa Create new Mis based on this Mis lf raw material costs have been entered then the calculation also gives the material cost of the mix 14 As mentioned previously all mix designs based on dry weights To compensate for water included in actual materials that are not dry the computer increases the batched weight of the non dry material so as to be equal the required weight of dry material The extra weight is water that the computer then subtracts from the batched water in the mix design sW Aggregate Moisture Water Solids Aggregate Moisture Water Solids Solids a The moisture may be adjusted in the table at any time
18. t could be created for one off jobs and all the detail recorded on an Order Anything written in Remarks is printed on delivery dockets 21 Orders Every Job no matter how small will require an order a Orders BETTER BRICKLAYIN BETTER BRIEELAYIE Outlook Dr Mindery BETTER BRIEELAYIE Update Cancel The order is for one mix design only and largely controls everything other than the load size and truck when a load is batched Materials that have been set up as modifiable will show on this screen Retarder RE in this case the mix design value of 120mls 100 kg cementitious may be changed The changed value will replace the mix design value whenever this order is used modifiable materials can also be changed at batch time without changing the order Plus means that more than the ordered quantity can be batched against this order Completed should be ticked when the order is finished to limit the number of orders to choose from on the new batch screen 22 Recent dockets firstly gives a list of dockets with the most recent docket listed first a Recent Dockets E OIA E gt Em 5 TEST T T 157 TEST 485 C No TET SM EDEN ee 164 SHEDMEN w S No No 7 NM aor No No 5 Wwe ls No No OE RT No No No No No No T Ho EST l ET TEST Noo EST 1 ET TEST Noo by
19. uest for 8 cubic metres would result in two drops each of 4 cubic metres These drops would have the same batch number and a single docket is generated Docket printing can happen at one of 4 different places in the batch cycle as shown above The batch time printed on the docket will be the time that the docket was first generated Reports are always printed to the Windows default printer The printer for dockets may be selected form the Docket Printer drop down which lists all printers installed to the batch computer 16 The Docket Style allows for different printer types and stationery Laser1 setting produces a single page output and is suitable for both laser printers and impact printers that have multi part continuous forms aser2 and Laser3 settings are for laser style printers only and will produce 2 or 3 copies of the same docket allowing plain single sheets to be used rather than multipart forms Serial Number Site Prefix Phone D Fax Site Details Docket Printer OKI MICROLINE 320 TU gt Email address es to send transaction data Iw Print Docket Determining Configuration At Start of Batch ingl Block Plant Tandem agg bin AL Start of Loading aximum single 75 batch size Moisture Probe Wet Mix Plant At End of Loading End of Slumping Docket Style Miscellaneous Relays Laser If no stationary mixer then counter MUST be set to Mone Days history kept Cou
20. ve Chemical admixtures such as plasticizer may be either Admix or Additive The only reason for having 2 admixture classes is to give added flexibility to the loading sequence E g it is possible to specify that some admixtures are loaded up front and some with the tail water The Order is the position that the counter is to be displayed on the computer screen and is generally chosen so that the computer screen has a similar layout to the position of the actual scale indicators in the batch room Settle Time is to eliminate the effects of dynamic loading when recording batch weights When falling material lands in the weigh hopper the scale reading will be greater than the steady weight The final batch weight reading is not taken until after the settle time has elapsed Choose the value by using the manual controls to drop some material and observe how long after closing the actuator the scale takes to assume a steady reading Zero is the scale reading that below which a hopper is considered to be empty It is common for some product to adhere to the sides of a weigh hopper scale reading may be zero before the weigh hopper was filled but after the hopper is emptied a true return to zero reading may not be achievable The batch computer will attempt to empty a hopper to the original start reading but if after a finite time zero can not be achieved the batch computer will consider the job done as long as the reading is less than the Zero value
21. would increase by 30kg for that bin on the next batch in order to get the correct target weight Whenever the batch program is restarted the original precut is used on the first batch The Jog Time is in milli seconds and is the incremental time that the feed will operate in order to feed some more material to achieve target If the Precut is too large then the batch time will be excessive as lots of jogs will be required to reach target The jog time needs to be chosen by experiment A small value will give accuracy in reaching the target but may require an excessive number of jogs Too large a value will feed material in larger increments with the possibility that the increment is so big that the last jog takes the material over tolerance A properly tuned plant will have good values for precut and jog time If the jog time is zero then no jogging will take place It is usually not advisable to jog bins that are pump operated In this case spend time getting the precut right If the bin has a connected Vibrator to help with slow or stopped feed then select the correct vibrator from the drop down Weigh Hoppers st Hoppers Name 4GG1 Counter AGG SCALE gt Class AGG Gates 2 Helay Humber Pulse length Open Close Is Open Is Closed ilti Seconds First Gate n Li Lora a o Second Gate Ff ff a Vibrator AGG VIE Conveyor AGGREGATE Enabled Save Lancel The Class of the hopper must be the same c
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation - Content of bach.arts.kuleuven.ac.be Manuel d`utilisation de la maquette AEROGENERATEUR A TURBINE IMPERIA_1450-@1@ (Page 1) KeTop T50VGA Handterminal Projektierungshandbuch V LPC185x/3x/2x/1x - NXP Semiconductors ALIMAK APF Technical Description & Instruction Manual Copyright © All rights reserved.