1. and set the appropriate settings Press Start Boot Load to begin download When downloading the bin file select 175 or A to store the file After the selection connection can only be made when you place the device on the cradle If you selected 175 in step 2 you must also select 2 Activate to begin the download procedure If you selected A in step 2 the download procedure begins right away It is not necessary to select 2 Activate to begin the download procedure The procedure can not be undone once it begins 19 Z 900XBT Activate Use this option to activate ZEBEX OS Customer Program to the device Activate Select where 1 2900XBT_fw_x xxx program is activated A 2900XBT fw x xxx Program currently running ESC Exit 1 Select an available option from 1 5 and press Enter for detailed information 2 Press F3 to activate once in the detailed information screen 3 Press ESC to exit Program Manager after activation to begin using ZEBEX OS Customer Program Z 900XBT 20 Upload Use this option to upload ZEBEX OS Customer Program to PC Upload Select where to 1 2900XBT_fw_x xxx upload the file A z900XBT_fw_x xxx File currently running ESC Exit O When uploading the bin file select 175 or A to store the file After the selection connection can only be made when you place the device on the cradle 21 Z 900XBT Wireless Operation Power on the device and look f
2. 3 When the data collector is found right click it and select Search Services 4 Enter the pin code to complete the pairing 5 Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host 6 The antenna logo will stop blinking upon connection with signal bars showing by its side 7 Select Transfer and Receive Application in ZAC Select the correct COM port and enter the password Finally select Start Upload to begin sending files i ZEBEX Application Creator 1 1 0 0 TEST 2014 2 5 ZAC da Receive Application Communication parameters COM AUTO Baudrate 115200 Interface R5232 USB VCOM x Directory Password 5 digits Send Lookup Direct Link Data Transfer File Name UploadZAC zac E Browse ES Menu E a LookUp Form Start Upload 8 You may check the files on your PC when uploading is done Z 900XBT USER S MANUAL Upload Lookup Files 1 To set the device to BT mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes Upload data or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set 5 Connec
3. Des CripllO a A ta 18 NAAA RSS R EET ERE ES REESE FRE SENSE ESSENSEN TEE SEERE 19 ACV Cai leida 20 Uploddaar ia a ad td edil 21 WIRELESS OPERATION ooocncocnnononononnocanncnnocnocanocnnconnonnnonanonononn cono conncnnnonoconncanncanocnnoonns 22 DOWNLOAD FILES vercion tae erne 22 Download ZAC FU a R 22 Download Lookup Files 2222 cases nernrenenern renerne arar 24 UPLOAD FILES No e e A a T E deren E AOT 26 Upload LACA E EE 26 Uplo d Loop E o EEEa 28 OUIDUELO CTC A A ERE ORE E EEA DRE 30 Output to Record a rede 32 UPDATING FIRMWARE ovio 34 iii Z 900XBT USER s MANUAL Introduction Z 9000BT redefines simplicity with more simple features and less complicated options With wireless connectivity users can transfer data instantly allowing seamless real time reporting and inventory control Enhanced with the brand new easy to use ZEBEX Application Creator program Z 9000BT allows users to achieve maximum efficiency through intuitive settings and user friendly interfaces Features e Transflective LCD for a wide working condition e No programming background required o Wireless connectivity PC System Requirement o Windows XP Service Pack 2 or above o Microsoft Internet Explorer 5 01 or later o Microsoft Framework 2 0 Package Contents Items contain in the package may vary depending on the model of the data collector ro 2 SO y Data Collector Li ion Battery USB Cable Power Adapter H
4. Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host The antenna logo will stop blinking upon connection with signal bars showing by its side Select Transfer and Send Lookup in ZAC Select the correct COM port then select Start Download to begin sending files Lu ZEBEX Application Creator v1 1 0 0 TEST 2014 2 5ZAC ZEBEX lt E s Download Lookup e Communication parameters MENE Tools Help a COM COM1 Y Baudrate 115200 Y gt Send Application Y Interface RS232 USB VCOM w File Name amp Receive Application Direct Link Data Transfer 8 Start Download 25 Z 900XBT Upload Files Upload ZAC Files 1 To set the device to BT mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes Upload data or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set 5 Connect to MAC and enter the host MAC address IL For BT SPP Slave mode no additional action is necessary 2 Select Search Devices from the IVT program on your PC to find BT devices A Turn ON Wireless Property Z 900XBT 26 USER S MANUAL
5. ZEBEX www zebex com User s Manual Portable Data Collector Series Revision History Changes to the original manual are listed below ZEBEX INDUSTRIES INC Version Date Description of Version 1 0 11 01 2014 Initial release Data Collector Series User s Manual 11 01 2014 Important Notice No warranty of any kind is made in regard to this material including but not limited to implied warranties of merchantability or fitness for a particular purpose We are not liable for any errors contained herein or incidental or consequential damages in connection with furnishing performance or use of this material No part of this document may be reproduced transmitted stored in a retrieval system transcribed or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written consent and authorization We reserve the right to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned herein registered or otherwise are the properties of their various respective owners Power Supply O Use only the type of battery and the charging equipments that came with your scanner O Using any other type of battery and charging equipment may damage the
6. view the information 3 In Date File press the function key 8 to edit data and press the function key 9 to delete data Delete Data Use this option to delete inputted data 1 Select 3 Utilities and 3 Delete Data from the menu 2 Select Date File or a Lookup to delete data 3 Select All data to delete all inputted data or Last one to delete the last inputted data 4 Select Cancel to exit Reader Test Use this option to identify the type of the barcode scanned 1 Select 3 Utilities and 4 Reader Test from the menu 2 Press the scan button to scan a barcode 3 The barcode information displays on the screen Z 900XBT 16 Set Date Time Use this option to set the date and time for the device 1 Select 3 Utilities and 5 Set Date Time from the menu 2 Press 1 to enter the calendar screen or 2 to enter the time screen 3 Use the numeric keys or the W or A keys to set the correct date and time Load Application This option enables you to load the settings you configured on ZAC to the device 1 Follow the previous instructions to connect the data collector 2 Select 3 Utilities and 6 Load Application on the data collector 3 Select Send Application in ZAC Memory amp Power Use this option to display the memory and battery information 1 Select 3 Utilities and 7 Memory Pow
7. will stop blinking upon connection with signal bars showing by its side Select 1 Collect from the data collector menu When you are done entering data press enter and wait for connection to establish An error message may appear if you fail to enter the correct MAC address in SPP Master mode When connection is established data will transfer to the PC AccessPort COM6 115200 N 8 1 Opened vonl Gh Bean 2 31 Z 900XBT USER S MANUAL Output to Record 1 Open ZAC and select Output record from the Record Action menu in Form File Transfer Tools Help anes gt a Application Template Formi w StartUp Le Settings E Menu When Pressing ESC go to Fg LookUp Form feom Next Navigation 0 8 8 Main Form2 Form 1 Form3 Record Action Form4 j Form5 Dutput record El Form Form7 Lookup Table Form8 Form9 O No Lookup 1st Lookup Form10 2 Download this file to your data collector See Download ZAC files section 3 To set the device to BT mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes Upload data or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set
8. 5 Connect to MAC and enter the host MAC address ll For BT SPP Slave mode no additional action is necessary Z 900XBT 32 4 10 USER S MANUAL Select Search Devices from the IVT program on your PC to find BT devices BlueS leil woe Turn ON Wireless Property When the data collector is found right click it and select Search Services Enter the pin code to complete the pairing Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host The antenna logo will stop blinking upon connection with signal bars showing by its side Select 1 Collect from the data collector menu When you are done entering data press enter and wait for connection to establish An error message may appear if you fail to enter the correct MAC address in SPP Master mode When connection is established data will transfer to the PC AccessPort COM6 115200 N 8 1 Opened vonl Gh Bean 2 33 Z 900XBT USER S MANUAL Updating Firmware 1 Power off the unit 2 Press 8 and the Power key at the same time to enter Program Manager Program Manager 1 Download 2 Activate 3 Upload Z9000PM _VXX XX ESC Exit 3 F SystemFont 000 ESC Exit 4 Select an empty slot to to store the file and press Enter Please remember the slot number you selected for later use Z 900XBT 34 USER S MANUAL 5
9. The Please Plug The USB Cable screen appears Connect the cradle to the computer and plug in the power adapter place the unit in the cradle when ready Please install the Z 900XBT driver if necessary oo Q0 G LY a 6 On your computer please open the Boot Load Utility default path Start gt All Programs gt ZEBEX gt ZAC gt Boot Load Utility 7 Check the Device Manager on your computer for the COM port your data collector is using 8 Select the same COM port in Boot Load Utility Boot Load Utility Rey 3 0 4 2 DE Boot Load Utility Rev 3 0 4 2 Company O RS 232 USB O Use PC time to set device time Historical Files Comport Settings Eire e Language Default v COM COM4 Baudrate 9600 v Parity None Load File DataBits 8 y StopBits 1 gt amp Start Boot Load Stop B 35 Z 900XBT USER S MANUAL 9 Select Load File then select the firmware file stored on your computer Boot Load Utility Rev 3 0 4 2 LOA Boot Load Utility Rev 3 0 4 2 Company RS 232 USB J Use PC time to set device time iB Historical Files Comport Settings Aran rl Language Default v CoM comt ii Baudrate 9600 v Parity None M F oad File DataBits 8 v 1 y StopBits Q Start Boot Load Stop Boot Load 10 Select Start Boot Load to transfer the file to Z 900XBT You will hear a bee
10. ace RS232 USB VCOM y Start Upload 29 Z 900XBT USER S MANUAL Output to Screen 1 Open ZAC and select Output screen from the Record Action menu in Form Forml Navigation Date Time Form When Pressing ESC go to O No Stamp Main O Before the Lookup Table O No Lookup 1st Lookup No Type Prompt 2 Nil 2 Download this file to your data collector See Download ZAC files section 3 To set the device to BT mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes Upload data or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set 5 Connect to MAC and enter the host MAC address Il For BT SPP Slave mode no additional action is necessary Z 900XBT 30 4 10 USER S MANUAL Select Search Devices from the IVT program on your PC to find BT devices BlueS leil woe Turn ON Wireless Property When the data collector is found right click it and select Search Services Enter the pin code to complete the pairing Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host The antenna logo
11. acters by lines 16 characters by 8 lines LED Status 1 green color LED and 1 red color LED for indications Wireless RF wireless compatible with SPP HID profile mode 3 Z 900XBT Data Capture This table gives the default settings of the symbologies Symbology Default Codabar Enable Code 39 Enable Code 93 Enable Code 128 Enable Code 11 Disable Italian Pharmacode Disable Chinese Post Code Disable Interleaved 2 of 5 Enable EAN UPC Enable MSI Disable Telepen Parameter Disable Industrial 2 of 5 Disable Standard 2 of 5 Disable Matrix 2 of 5 Disable GS1 Databar Disable Z 900XBT Symbology Code ID Default Codabar N Code 39 M Code 93 L Code 128 K Code 11 O Chinese Post Code H Interleaved 2 of 5 EAN 13 F UPC A A UPC E E EAN 8 FF MSI P Industrial 2 of 5 D Standard 2 of 5 S Matrix 2 of 5 G GS1 Databar RS GS1 Databar Expanded RX GS1 Databar Limited RL Z 900XBT Symbology Barcode Length Codabar Code 11 Maximum 32 Industrial 2 of 5 or Standard 2 of 5 Minimim 6 Matrix 2 of 5 Maximum 62 Minimim 3 Code 39 Maximum 62 Code 93 Code 128 Minimim 3 Maximum 62 Minimim 3 Chinese Post Code Maximum 16 Minimim 10 Interleaved 2 of 5 MSI Maximum 32 Minimim 4 Maximum 32 Minimim 4 GS1 Databar GS1 Databar Limited Maxim
12. and Strap 1 Z 900XBT USER S MANUAL Overview Refer to the following illustrations to familiarize yourself with the data collector E Scan Window LED Indicator Buzzer LCD Screen Battery Compartment Keypad Battery Lock Hand Strap Battery Hole Contacts Description Function Scan Window Emits a red beam for barcode reading Battery Compartment Batteries are stored here Battery Lock Secures the battery compartment Hand Strap Hole Used to attach hand straps Indicates reading status LED Indicator Red for scanning error such as wrong data type or no data match and green for good read LCD Screen Display various data when a program is being run A total of 21 keys are provided to the power and Keypad i other function keys Battery Contacts For charging battery Buzzer Emits audible indication sounds Z 900XBT 2 Device Information Battery Main Battery Li ion battery pack 3 7V 1150mA Battery Life 150 hrs Laser CCD version based on one scan per 5 secs Backup battery Lithium battery 3 0V 15mAh Charging current 500mA MAX Auto charger off timer 6 2 hrs Memory 8MB FLASH ROM AMB SRAM with ability to data retentions Keypad 21 keys alpha numeric include Power and SCAN key with white back light LCD Screen LCD type 128 x 128 graphic mono FSTN LCD LCD backlight LED White View Area 43 0 x 42 8mm Font size 8 15 pixels Char
13. attery Menu Screen Menu Description Menu Description Select this option to start recording data You can cates scan barcodes or enter the data manually Select this option to e Upload Data file Upload e Upload lookup file e Upload all files 1 by 1 e Upload all files as append 11 Z 900XBT Task Utility Select this option for 1 2 3 4 5 6 7 8 9 Settings Browse Data Delete Data Reader Test Set Date Time Load Application Memory amp Power Calculator Load Lookup when lookup is available this option becomes option 8 and calculator becomes option 9 Z 900XBT 12 USER s MANUAL Using the Data Collector Refer to the following section to learn how to use the data collector Scanning and Keying in Data The keypad includes alphanumeric assorted characters navigation and function buttons Up Down buttons Scan button Back space button ESC button Enter button Function button Alpha a button Scanning the Barcode Data 1 Power on the device and select 1 Collect to enter scanner mode Press and hold the yellow SCAN button A light beam will be activated and shoot out from the window at the lower front end of the data collector Please see the Run Task section in the User s Manual for more details 0000 2 Aim the beam at the barcode to be scanned A beep will be give
14. ct the correct COM port then select Start Download to begin sending files Us ZEBEX Application Creator v1 1 0 0 TEST 2014 2 5 ZAC Tools Help a 3 2 Send Lookup send Application Communication parameters le Direct Link Data Transfer com COM1 v Baudrate 115200 Interface R5232 U5B VCOM a E Ey LookUp B E Form 23 Z 900XBT USER S MANUAL Download Lookup Files 1 To set the device to BT mode select 3 Utilities 1 Settings 2 Download Port from the device menu and select SPP Master or SPP Slave modes Download Program Or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set 5 Connect to MAC and enter the host MAC address Il For BT SPP Slave mode no additional action is necessary 2 Select 3 Utilities 8 Load Lookup and wait for the device to connect An error message may appear if you fail to enter the correct MAC address in SPP Master mode 3 Select Search Devices from the IVT program on your PC to find BT devices Search Devices Turn ON Wireless Property Z 900XBT 24 7 8 USER S MANUAL When the data collector is found right click it and select Search Services Enter the pin code to complete the pairing
15. er from the menu 2 The memory and battery information displays on the screen Calculator Use this option to use the data collector as a calculator 1 Select 3 Utilities and 8 Calculator or when lookup is available select 9 Calculator 2 Use the numeric keys to enter numbers key to toggle between x enter key for BS for back space and ESC to exit 17 Z 900XBT Load Lookup Use this option enables you to load lookup table to the device from ZAC 1 Follow the previous instructions to connect the data collector 2 Select 3 Utilities and 9 Load Lookup on the data collector 3 Select Send Lookup in ZAC Program Manager Press the numeric key 8 and power button at the same time to enter Program Manager Menu Description Program Manager 1 Download 2 Activate 3 Upload Z9000PM _VXX XX ESC Exit Download ZEBEX OS Customer Program to the Download i device Activate Activate ZEBEX OS Customer Program Upload Upload ZEBEX OS Customer Program to PC Z 900XBT 18 Download Use this option to download ZEBEX OS Customer Program to the device Must be used along with Boot Load Utility Rev x xx exe Download eras elect where bin is 1 29000_fw_x xxx 7 saved A z9000_fw_x xxx Location where bin can be Where system F SystemFont 000 executed font is stored ESC Exit Execute Boot Load Utility Rev x xx exe
16. k the Include this location option and use Browse to locate the driver in your computer Click Next to go to the next step Click Next and Finish when the installation is done Power on the Device Press and hold the power button to turn the power on or off Z 900XBT USER s MANUAL Connecting to PC To use the software supplied with the data collector it must be connected to a PC To connect wirelessly please see the Wireless Operation section Connecting via Cradle To connect the data collector to a PC via cradle 1 Place the data collector on the cradle and connect the cradle to PC using the USB cable 2 The PC should auto detect the device as a COM device and ask for the driver when connecting the first time 3 Please download and install the driver from ZEBEX website The system should assign a COM port to the device after the driver installation e Connect the power adapter to the cradle when necessary O Make sure the unit is turned on after the cable is connected O Check the COM and LPT section in the device manager for the assigned COM port The data collector should appear as a virtual com device Running the Device on PC 1 Install and run ZAC on your PC 2 Make sure the virtual COM port driver is installed 3 Run any connection program on ZAC For more details please see the ZAC User s Manual 4 Check the device manager on your PC for
17. king with included utilities The utilities menu includes the following options Settings Settings allow you to manage and view the system parameters Use the Y or A buttons to move the cursor and press enter to select the value Setting Upload Port Value Cradle USB BT SPP Master BT SPP Slave Function View the communication setting for uploading Download Port Cradle USB BT SPP Master BT SPP Slave View the communication setting for downloading Baud Rate 9600 19200 38400 57600 115200 View the baud rate for connection Backlight Turn B L off Turn B L on Turn the backlight on or off Data Deletion Manual Automatic No Decide data deletion mode Entry Option No Prompt Show Count Show Data Decide what to show after an entry You can also set the prompt time by entering a number Buzzer Key Click Barcode Read Warning Beep In Key Click select tone1 5 or mute for the key sound and select one to three beeps or mute for the Barcode Read and Warning Beep View Settings System parameters All the system parameters set are displayed here Cursor Mode Disable Cursor Fixed Cursor Blink Cursor Decide the cursor mode for data input 15 Z 900XBT Browse Data Inputted data and the data in lookup can be viewed here 1 Select 3 Utilities and 2 Browse Data from the menu 2 Select Date File or a Lookup to
18. n and the beam will disappear if the data scanned has been successfully decoded by the data collector The decoded message will then be displayed in the LCD 3 The scanned data will be stored as soon as the SCAN button is released and the next barcode is ready to be scanned 13 Z 900XBT Keying in Data via keypad Inputting Numerical Data o To input numerical data press the corresponding keys o To save the input data press Enter after the data is input o To delete the data press the Back space button Inputting an alphabetical character o To input an alphabetical character first find the appropriate key The following table displays the numerical keys and their corresponding alphabetical characters o Press the key and the numerical character corresponding to the key will be displayed Pressing the Q key to switch between alphabetical and numeric entry A 1 or A or a appears on the screen indicating the current mode When in the alphabetical entry modes A or a press the keys repeatedly until the desired character is approached Corresponding Characters 2 A B C a b c 3 D E F d e f 4 G H l g h i 5 J K j k 6 M N O m n o 7 P Q R S p q r Ss 8 T U V t u v 9 WwW X Y Z w x y Z 0 5 1 Space z Z 900XBT 14 Working with Utilities Select 3 Utilities from the menu screen to begin wor
19. ocardia 9 Connecting via Cradle iia dedicas 9 Running the Device On Plat idas 9 Loading Application from PC wiccccccccecsccesessesesesseesceeeseesecseseecuseeeceseeseesecseeeeneseeenaeets 10 Loading Lookup table from PC ccccccccccsccessescecesseesceseeseeecseesecuseeececeeseeseceeeeneseeeaeets 10 Resetting the Device oia a E aaa adi 10 Uploading Data A A A Add res 10 Working With Menus isis ia a ai DE eae eves 11 Men Description roinn A A E A DA oe NEE Ns 11 USING THE DATA COLLECTOR 00 cscccssssscccsssccsssscccessssccecssccesssacceesseccesssseeessnee 13 SCANNING AND KEYING IN DATA Wu ccecsessssesececeesesccecececseneneseceeeceesesssaeceecesesensaeceeeeeees 13 Scanning the Barcode Data cccccccccccsccsseecesesseesceeescesesseeesuseeecnseeecesecseeeeneeeeeneeenenaes 13 Keying in Data via keypad c cccccccescccssesceseescesesseeecseeeecseeecceescesecseesecueeeeeaesntensenseets 14 WORKING WITH UTILITIES 6025 ccsccicesesceccecsessdcesenceccvcssdeisecttcacseseosectdeacasvosvedvicescasssevecetedses 15 SEMINO Sick Me ea a ted e Si oon Da el dan ada es alan ated 15 Browse Dalas ea a e as td a ed oa o 16 Delete DG a di 16 Z 900XBT ii Read a bexeed 16 Set Datel TAM Cine es it ec A liado 17 LOGE Applications Geceee xs a ET Eve ote bois 17 Memory de PoWer vc EU inin n EEEE EE E EEE E EEEE EERE 17 Calcula a a A eee BS Da ae ed n asd E on aa 17 Load Lookup oil ia aer 18 PROGRAM MANAGER ag oree ea nae E na E EEN o E rn 18 Meni
20. or the blinking antenna logo The logo indicates the support of BT connection sfe Download Files Download ZAC Files 1 To set the device to BT mode select 3 Utilities 1 Settings 2 Download Port from the device menu and select SPP Master or SPP Slave modes Download Program Or lookup file via 1 Cradle USB 2 BT SPP Master 3 BT SPP Slave Enter Select ESC Cancel l For BT SPP Master mode please select 3 Utilities 1 Settings next page 4 Bluetooth Menu 2 Connect Set 5 Connect to MAC and enter the host MAC address ll For BT SPP Slave mode no additional action is necessary 2 Select 3 Utilities 6 Load Application and wait for the device to connect An error message may appear if you fail to enter the correct MAC address in SPP Master mode Z 900XBT 22 USER S MANUAL 3 Select Search Devices from the IVT program on your PC to find BT devices BlueS teil Sua Turn ON Wireless Property 4 When the data collector is found right click it and select Search Services 5 Enter the pin code to complete the pairing process 6 Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host 7 The antenna logo will stop blinking upon connection with signal bars showing by its side 8 Select Transfer and Send Application in ZAC Sele
21. p sound when the transfer is done The Download screen appears on the Z 900XBT screen Press ESC to exit the screen when ready Boot Load Utility Rey 3 0 4 2 ALA Boot Load Utility Rev 3 0 4 2 Company RS 232 USB O Use PC time to set device time FJ Historical Files comport Settings Firmware File Language Default Y COM COM4 M D V fw Z 2013 7 29 2 bin Baudrate 9600 v Parit None id Load File DataBits StopBits Start Boot Load stop Boot Load Z 900XBT 36 11 Select 2 Activate then select the file slot you selected in step 4 and press enter Program Manager Activate 1 Download 1 2900XBT_fw_x 3 Upload Z9000PM _VXX XX ESC Exit A z900XBT_fw_x xxx ESC Exit 12 Press FN and 3 at the same time to activate the file Information File attribute Name fw xxxxxx Size 352K CD 1970 01 02 CT 00 39 27 F3 Activate 13 A message appears on the screen Are you sure to activate file Use the up down arrow keys to select YES then press enter to begin update 14 The screen will return to the Activate screen when the update is done Upgrade Warning O Incorrect operation may cause dysfunction or damage to the unit O Please choose the correct firmware file e Do not remove power or reboot the system until the firmware upgrade procedure is complete to avoid possible damage to the unit 37 Z 900XBT
22. scanner and invalidate the warranty O The main and backup batteries may not be charged to full for shipment O Do not attempt to split or peel the outer casing O Remove the battery if the scanner is not going to be used for a long time If the battery is left unused for more than 3 months you need to charge the battery before Use Copyright O 2014 All rights reserved Guidance for Printing This manual is in A5 size Please double check your printer setting before printing it i Z 900XBT Table of Contents IMPORTANTNOTICE laaa aeea rE ESE ve Ee Tes eE S eese saae Esi I Power SUPPLY sretan en a e a ea eee i INTRODUCTION cheiie iaasa ea ea toe i ee a aseara ea sasidas lipasi iesise 1 FEATURES iia ET E E EE E REN 1 PE SYSTEM REQUIREMENT civil 1 PACKAGE CONTENTS cuidara dida diia E 1 OVERVIEW oir da dd iia vita 2 DEVICE INFORMATION vesssssccoescescccssvsvcssesectesssastsessveccesssoonsedsecsessoensvdensecsvssscesevsveseeesenve 3 BATERIA A A e odds 3 MEMORY rosenen nne A acci n 3 KEYPAD rt A cat 3 TED SCREEN rita A A a rad 3 BED STATUS Sn es eat 3 WIRELESS ett ir e tl ta o el O 3 DATA CAPTURE o ei ceo Md net E sn Rn se 4 GETTING STARTED A codessds te tasssacevessdasesssstuvssdsie tess casedess tovscdestesssessseeses 7 INSERTING BATTERY earan A Saas Hie aN dida aia 7 CHARGING THE BATTERY mici kurna i iaa 7 INSTALLATION 3 a iba 8 POWER ON THE DEVICE iii ives suv A duet tds cca Seadise cucdhesaceteawedtioes 8 CONNECTING TO Pr
23. t to MAC and enter the host MAC address Il For BT SPP Slave mode no additional action is necessary 2 Select 2 Upload ALL Append and wait for the device to connect An error message may appear if you fail to enter the correct MAC address in SPP Master mode 3 Select Search Devices from the IVT program on your PC to find BT devices BlueS leil Tk pon Turn ON Wireless Property Z 900XBT 28 USER S MANUAL 4 When the data collector is found right click it and select Search Services 5 Enter the pin code to complete the pairing 6 Right click on the data collector in IVT program and select Connect Serial BT Device to connect the device to the host 7 The antenna logo will stop blinking upon connection with signal bars showing by its side 8 Select Transfer and Direct Link Data Transfer in ZAC Select the correct COM port and the file and select Start Upload to begin sending files ER Data Reader File Properties File Name Un ZEBEX Application Creator wan uty New File ZAC EN overwrite al Encoding ANSI v h ZEBEX 4 Add Return character to each record Add Line Feed character to each record File Tools Help Y View the received data 4 Data Convert Send Application amp Receive Application Communication parameters com auro sy Baudrate 115200 w S Send Lookup Interf
24. the COM port and set the same value in ZAC Setting to connect the device 9 Z 900XBT USER S MANUAL Loading Application from PC 1 Follow the previous instructions to connect the data collector 2 Select 3 Utilities 6 Application on the data collector 3 Select Send Application in ZAC Loading Lookup table from PC 1 Follow the previous instructions to connect the data collector 2 Select 3 Utilities and 9 Load Lookup on the data collector 3 Select Send Lookup in ZAC Resetting the Device 1 Press and hold the Y and A buttons then press the Power button 2 Release the Power button when you see the reset message on the screen 3 All settings will reset to the default values Uploading Data 1 Follow the previous instructions to connect the data collector 2 Select 2 Upload from the menu screen to start uploading data 3 Select the data to be uploaded in the next screen and press enter or press ESC to exit 4 Select Transfer Direct Link Data Transfer in Zac to start upload Z 900XBT 10 USER s MANUAL Working with Menus o Press the Y or A buttons or the number keys to move the cursor to the desired option O Press the Enter key to enter the menu option O Press ESC to go to the previous screen 1 Collect 2 Upload Menu selection 3 Utilities Recs 0 000 015 SN 29000 0333 MAR19 11 05 Zbx TL 14 USB Cit Keypad USB Battery status B
25. um 14 Minimim 14 GS1 Databar Expanded Maximum 48 Minimim 6 Z 900XBT Getting Started Refer to the following illustrations to learn the basics of the data collector in this section Inserting Battery 1 Push the lock lever to unlock the battery lock 2 Remove the battery cover from the data collector 3 Insert the battery with the top side in first then the side with battery contact The battery is held in place by a small lock on the bottom of the compartment Push the battery in until it clicks into place 4 Slide the battery cover back on to secure the battery Charging the Battery 1 Place Z 900XBT on the cradle 2 Connect the power adapter to the cradle and to a wall outlet 3 Battery status on the LCD screen indicates that your battery is charging 7 Z 900XBT USER S MANUAL Installation Follow the instructions below to install ZAC driver on your computer 1 Connect the device to your computer via USB cradle A window appears in the bottom right hand corner of Windows that says Found new hardware In a few seconds a Found New Hardware Wizard window opens up Double click the found new hardware icon to pull up the window if it does not appear automatically Select No not this time to continue Click Next to continue installation Click Install from a list or specific location Advanced and click Next Chec