Home
        EUROMASKI VL
         Contents
1.  1786000   Page 3 Of 4       Honeywell International Inc     EUROMASKI VL  welding helmet for PAPR use     FILTER    Spare Parts    REF N   REFERENCE  DRAWING   1 A160143   2 A160213   3 A160790  A160791   A160792   A160794   A A160644   5 A160784  A160785   A160786   6 A160787   7 A160026   8 A161472   9 A160194    Spare Parts File  Euromaski VL Technical View    DESCRIPTION    Comfa Seal   EUROMASKI    Headband airduct assembly    UV filter shade 1 7  standard   UV filter shade 3  optional   UV filter shade 5  optional   UV filter clear  optional     Visor frame    Visor filter shade 5  optional   Visor filter shade 8  standard   Visor filter shade 10  optional     Big visor filter shade 8  optional     UV filter mounting stud    Sweatband    Protective Cover    Packaging    EAN Code  8713223157179    Packaging Specs Individual Box  25 x 32 5 x 30   Gross Weight 1 200kg    Unit of Measure  cm    Quantity per Box Pack Case  4    Quantity per Carton  A    Quantity for Minimum Order  4          Honeywell International Inc     Page 4 Of 4       Honeywell International Inc     30 7 2015 218412d5 9a62 41b7 b9a7 e5b972bf74d0 jpg  694x262        http   www honewwellsafety com assets 0 324 852 853 218412d5 9362 41b7 b9a7 e5b972bf74dO jpg    u          1 1    
2. Honeywell Europe   Africa    PRODUCT NUMBER  A114703  EUROMASKI VL    EUROMASKI VL is part of the Honeywell welding helmet  range designed for use with powered air purifying respirator   PAPR  as Compact Air 200 and Compact Air  It is equipped  with visor with UV and IR protection    It is recommended in working area where protection is  required for respiratory organs  face  head and shoulders  against harmful particles  mists  gasses and vapours    This system procures air to the user via the supply hose  connected between PAPR  equipped with filters  and the  helmet  The filtered airflow enters at the rear and flows  through the airduct and leaves the hood via the face collar or    the neck bib  Honeywell          Overview    Reference Number  A114703    Product Type  Respiratory Protection    Range   Powered Air Purifying Respirators  Line   PAPR with Hoods or Visors    Brand  Honeywell    Brand formerly known as  NORTH    Industry    e Administration e Automotive and Part Manufacturer e Building and Construction e Energy or Electricity  e General Industry e Maintenance e Welding    Product Use   e Arc welding   e Grinding   e Cutting with a gas torch    Features  amp  Benefits    Feature  Extremely lightweight design    Feature  Comfortable cotton elastic face seal    Feature  Wide field of vision without raising the visors to spot possible danger    Feature    Page 1 Of 4     Honeywell International Inc     EUROMASKI VL  welding helmet for PAPR use     Comfortable cotto
3. ir or Compact Air 200  to the rear of the  air hood     e Buckle the belt round the body and switch on the respirator   e Adjust the head band to the correct length     e Fit the helmet on the head  draw the face collar back under the chin  so that the hood is sealed off  and then tighten the  belt     Cleaning   e After each session clean the helmet  using a mixture of water and a mild  solution to ada   e Subsequently  rinse thoroughly with clean water   Do not use any solvents     e The face seal can be washed in the washing machine  using a soft detergent at 30   C    e Using a disinfectant  clean the inner surfaces of the air hood    e Using a dry cloth  dry all the metal components  so avoiding corrosion     Parts  amp  Accessories    Accessories  References for use with Euromaski VL    TYPE DESCRIPTION REFERENCE    BLOWER Compact Air  200 Blower unit  rechargeable A150401  battery battery charger  belt with backplate breathing hose  for hoods  airflow indicator and plastic carrying case    Compact Air   Blower unit for particles  gasses and A150102  vapours   rechargable NiMH battery   support belt  P3 filter    hose and plastic carrying case    Airbelt Blower unit for particles including an electronic A150050  warning device for filter or low battery   with rechargeable   NiMH battery   charger   support belt   P3 filter and hose and   plastic carrying case    ALUMINUM PS A168091  FILTERS   A2P3 1783010   AB2P3 1783040   ABEK2P3 1784000   ABEKHgP3 1785019   PLASTIC ES
4. n elastic face seal    Feature  Versatile  welding shield and face in the same mask  can be used in different stages of work    Technical Description    Mask    Material  Light duty Nylon welding airhood   Face seal in cotton    Visor Screen  Double visor system    Reusable    Filter Cartridge Connection Type  RD40    Number of Filter Cartridges  3    Protection  Combination    Certifications    A E C  Declaration of Conformity    EC Category PPE  3    EC Certificate Number  7338 A 12 37 PSA    EC Attestation  A CA200 CE Certificate    EC Attestation Number  7338 A 12 37 PSA    Certifications  e EN EN12941       Literature  amp  Documents    DOC3188 Compact Air 200 Series UK  http   www honeywellsafety com supplementary documents_and_downloads respiratory_protection   papr 4294974975 1033 aspx    Additional Information    User Manual  User Manual    Maintenance    Life Cycle  Storage Information    Page 2 Of 4     Honeywell International Inc     EUROMASKI VL  welding helmet for PAPR use     All respiratory products must be stored in a clean  dry environment away from any contaminants  dust and direct  sun in its original box  any carrying case     Care Instructions  Controls before use    e Ensure that the system  after being last used  has been cleaned in the correct manner  disinfected and checked in  accordance with manufacturer instructions inside user manual     Donning the Euromaski Helmet    e Connect the supply hose from the powered air purifying respirator  Compact A
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Bedienungsanleitung Second Edition  Studie Projektbericht    AAS 12 - Grifo      IS REOUESgRVICE  Argentium User Guide  OEM Systems Waterskis WS1.25EI User's Manual  AQL/AQH 20-75 AQC 40-75 - comatec wesper airwell    Copyright © All rights reserved. 
   Failed to retrieve file